HomeMy WebLinkAbout2525 EL CAMINO REAL; 231; FPC2017-0351; PermitPermit No: FPC2017-0351 CARLSBAD, CA 92008-1209 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Status: Closed - Finaled Applied: 11/28/2017 Issued: 12/15/2017 Finaled Close Out: 02/11/2021 Inspector: Final Inspection: PERMIT REPORT City of Carlsbad Print Date: 02/16/2022 Job Address: 2525 EL CAMINO REAL, # 231, Permit Type: FIRE-Construction Commercial Parcel #: 1563020900 Valuation: $56,091.06 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: DANIELS JEWELERS -FIRE ALARM TI Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP SIMPLEX GRINNELL LP DOUGLAS DANIELS 3568 RUFFIN RD S 3568 RUFFIN RD SAN DIEGO, CA 92123-2597 SAN DIEGO, CA 92123-2597 (858) 633-9100 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SimplexGnnnell LP 3568 Ruffin Road tq a Diego, 92123 3-9100 Simp/exGrinne/I ° vIxinineI!.com Fire Detection and Alarm System Product Submittal Project: Daniel's Jewelers The Shoppes at Carlsbad 2525 El Camino Real Suite #231 Carlsbad, CA FPC2017-0351 2525 EL CAMINO REAL DANIELS JEWELERS - FIRE ALARM TI #231 1563020900 11128/2017 FPC20I 7-0351 Owl For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or ddanieIs(ãsimpIexqrinnell.com 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco .TM tqco ell SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4090-9010 Relay lAM 7300-0026:0311 1 4906-9204 Strobe 7125-0026:0235 3 49SV-APPLC Speaker Strobe 7125-0026:0384 Business Information Warranty Information [1 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco.Thl 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) Communications IDNet communications 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4WHx4"Wx1 %"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32* to 120* F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) B5implEx UL, ULC, CSFM Listed; FM Approved* I1uII3i Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For IDNet communications from the following Simplex® control panels: Model Series 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 '/" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow S LED to be viewed after installation UL listed to Standard 864 Dsrintie 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of 1-1VAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. 11M. ITIflRjI1 Model cripti 0-9O1O8ZiayWT3 Optional Trim Plates and Adapter Model Description 4090-9801 For semi-flush I Trim plate, galvanized mounted box I steel, with LED viewing For surface window; includes 4090-9802 mounted box mounting screws 4090-9813 Adapter plate to fit 4 11/16"(119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM S4090-0015 9/2014 8 A Relay JAM Mounting Information S 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © U I © © WAF*Orx Add supplied label to-1 I AVER11SSflENT: cover on-site if controlling IA118rnssaer:I 4-9/16" 120or240VAC LJ 4-5/16" (116 mm) (109 mm) Light pipe for LED viewing © © - _4~ © © -9I16" (116 mm) 4 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SiMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Si rn I EX Tyco Fire Protection Products• Westminster, MA 01441-0001 'USA S4090-0015 9/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocwnent revision date and are subject to change without notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4090-9118 relay lAM (individually addressable mod du r la IAM module with unsupervised feedback, 4090-9008 dual relay lAr4 Mn rAlqv n_ A I A A A4A_0 lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's d 3ta sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applica le codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately Ii ted compatible fire alarm control units. S *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S Sim plEx TrueA!ert Addressable Notification Appliances UL, ULC, CSFM Listed; FM Approved, r1 Multi-Candela Visible Only (V/O) MEA (NYC) Acceptance* 9-J- Appliances (Strobes), Ceiling Mount [I S I11Ii4i Individually addressed and controlled multi-candela VIO (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by J1)NAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and ULCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes * See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:235 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property at Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os I4-s irllr1 Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) kl!iflLX r i*i*i1ri']ti.tr.iIr.1 Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test lDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. S Product Selection Multi-Candela Ceiling Mount Addressable Strobe Model Housing "FIRE" Lettering Dimensions Description Color 4906-9202 Red White ,, ,, ,, Multi-Candela Addressable Strobe; 4906-9204 White Red (121 mXx27 5 mm x 7,m) 110 candela as: 15, 30, 75, or 8 8 888. 8.1 VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Ceiling Mount, Surface Mount Adapter Plate, zinc plated; required for 4%" x 3 'h' (124 min x 79 mm) ceiling surface mount Wire Guards (see diagram on page 3) Model Description Dimensions 4905-9926* Ceiling Mount Red wire guard with mounting plate, compatible with 6 1/8 x 4 M." X 2 semi-flush or surface mounted boxes (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/O 15 T14-1--2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 2 S4906-0004-4 2/2015 S S Bottom view Magnetic test location Ceiling Mount VIO and Guard Installation Reference I Fr) inn Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2' (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 wire guard Ceiling mount strobe Optional 4905-9926 wire guard with mounting plate ----------------------------------------- :"e Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is FACP, controlled by panel ------------------------------------------- Single gang box (Wiremold V5744S) 2-1/4" (57 mm) deep, supplied by others Address setting DlPswitch is behind strobe assembly, select address and strobe candela setting before inserting into housing S S LP!c!LC Controller Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 1 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4007ES with IDNAC Notification S4007-0002 4010ES with ESS Enhanced System Supply S4010-0011 Specifications General Specifications (see page 2 for dimensions) Environmental 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.52 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Installation Instructions 579-808 Strobe Specifications Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per NAC Candela Setting 15 c I 30 c I 75 c I 110 c 23 VDC RMS Current Ratings, for connection to IDNAC Addressable SLCs 60 mA 92 mA 180 mA 240 mA TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Controller Output Available Strobe Appliance Voltage Reference Intensity Minimum 4100ES or 4100U with TrueAlert Power Supply S4100-0031 TrueAlert Addressable SLC 15, 30, 75, and 110 cd .17 VDC 4009 IPS, Remote TrueAlert Power Supply S4100-0037 TrueAlert Addressable Controller (4009T) S4009-0003 Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 c 30 c 75 c 110 Cd 17 VDC RMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above S4906-0004-4 2/2015 S S TYCO, SJJvLPLEX and the product names listed in this material are marks and or registered marks. Unauthorized use is strictly prohibted NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). 0 J3.SiMpJr:X Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4906-0004-4 2/2015 www.simplexgtinnell.com 0 2015 Tyco Fire Protection Proth4czs All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7125-0026:0235 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models "TrueAlert non-addressable" 4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable" 4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models 'TrueAlert addressable" 4906-9201, -9202, -920 -9204, nd -9208 synchronized multi-candela strobe lights are intended for indoor use. * o e s 4 06-9201, -9203 and -9208 are intended for wall mounted only. *Models 4906-9202 and -9204 are intended for ceilingl mounted only. Intended for use with either Model 4209-9401 NAG Extender or with the TrueAlert power supply of Model 4100U fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data she] for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -9359, -9168, -9171: 15, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. "Rev 04-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ®Si m plEx TrueAlert Addressable Notification Appliances UL, ULC Listed; FM Approved* Ceiling Mount Addressable Speaker Visible Lfti (SN) Notification Appliances Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). SN notification appliances use a multi-tapped speaker for audio/tone notification and a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. Wiring supervision is electronically monitored and allows audio wiring to be 1-tapped for class B wiring, reducing wiring costs and wiring distances. Ceiling mount speaker visible appliances are available in 400 - 4000 Hz models and high fidelity models capable of operating between 200 - 10000 Hz. Separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWC-000 1. Ceiling Mount Addressable SpeakerNisible Notification Appliance Ceiling Mount Addressable Speaker SN Appliances lrueAlert ES Addressable SN appliance dimensions with cover: 8 'h' H x 7 'h' W x 3" D (206 mm x 180 mm x 76 mm) High Fidelity Appliances Model Description 49HFV-APPLC(-BA) High Fidelity appliance only. Select cover separately. High Candela Appliances Model Description 49SVH-APPLC(-BA) High Candela appliance only. Select cover separately. High Fidelity High Candela Appliances Model Description 49HFVH-APPLC(-BA) High Fidelity High Candela appliance. Select cover separately. 49HFVH-APLCA-BA High Fidelity High Candela appliance with amber colored lens. Select cover separately. 49HFVH-APLCB-BA High Fidelity High Candela appliance with blue colored lens. Select cover separately. SN Covers (Required when ordering APPLC models) Model Color 1wording Model Color Wording 49SVC-CRALT Red ALERT 49SVC-C WALT White ALERT 49SVC-CRBA &-9FlRE 49SVC-CWBA L3_-—/FIRE 49SVC-CRBC */FIRE ALARM 495VC-CWBC */FIRE ALARM 49SVCCRBF FEU/FIRE 49SVC-CWBF FEU/FIRE 49SVC-CRFEU FEU 49SVC-CWFEU FEU 49SVC-CR FIRE FIRE 49SVC-CWFIRE FIRE 49SVC-CRS Simplex logo only 49SVC-CWS Simplex logo only 49SVC-CK Black No logo or lettering * Note: (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in —BA are assembled in the USA * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire S49SVC-0001-2 11/2016 Flash Rate and Synchronized SLC Loading 23 VDC to 30 VDC, 1unitload (=0.8mA 1 Hz; with up to 63 s circuit, max 127SN 15 c I 30cd Candela Setting 495V and 49HFVmodels WH and 49HFVH models audio circuits. Anechoic speaker strobes maximum per powered er IDNAC channel [110Cd _135cd _185 Cd 193 mA N/A N/A I 235 mA 255 mA 295 mA S are typically more representative Current consumption** Note: Speakers are for connection to of actual installed sound output. IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 4100ES Constant Supervision and Signal Cards 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 L~eling Mount SIV Specifications Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Installation Instructions 579-1203 (495V, 49SVH and 49HFV models) 579-1206 (Amber/Blue 49HFVH model) Speaker General Specifications Input Voltage 25 0170.7 Vrms PowerTaps '/4,1/2,1, and 2W Frequency Response 400104000 Hz (SN, SNH), 200 to 10000 Hz General Signaling = 125 to 12 kHz (H/F, HFNH) Speaker Output Ratings 25 0170.7 Vrms @ 10 ft (3 m) Wattage Tap Model '/4W '/2W 1W 2W SN H/F SN I H/F S/V H/F SN H/F Reverberant Chamber Test, per UL 1480 (dBA) 79 76 83 80 86° 84 89° 87° Anechoic Chamber Test, per ULC-5541 (dBA)* 79 78 83 1 82 86° 85° 89° 88° elect taps as inaicatea to satisly me ULU lire alarm applications requirement 01 85 dBA minimum Polar Dispersion Reference (per ULC-5541 Anechoic Chamber Attenuation _Angle _Attenuation _Angle Testing) P_3 dB 70° -6 dB 80° Percentage of rated light output at room temperature Angle On-Axis Vertical, Horizontal Left/Rig htof Axis 0° 45* 90* 45° UL required output _45° _90° 45% _90° Typical output _100% _327% _45% _134% _25% _83% 129% _25% _47% S S 2 S49SVC-0001-2 11/2016 S Ceiling Mount S/V Installation Reference S Appliance with cover (front) f / Magnet test location indicated by area that is not textured ED 160%,0000006 0- 1/ ::::::8%%%' oOe00000000 00000000001D00 Appliance test points, I 0000000 0000000000000000 00,000000000000000000000 audio circuit power taps, 'J \ and address dip switch \ / \ 00 00O 000000000 o%%?00 / oo Set audio circuit power taps and device address before fixing cover in place. I I 1 • -1 • •- - dela flag setting I= Set flag to FACP to control candela rating from an FACP providing IDNAC notification. To set candela manually, set ,' 110 75 the flag to the desired 30 candela rating. is Use slotted screwdriver FACP , here to remove cover. S i S 3 S49SVC-0001-2 11/2016 Mount to 4 X 4" X 2-1/8" electrical box using 8-32 screws Note: Ceiling mount only Appliance (rear) 0- 0 S ~-I TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and S&nalina Code are registered trademarks of the National Fire Protection Association (NFPA). i Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S49SVC-0001-2 11/2016 mp EX C 2016 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: 49SV-APPLC, HFV-APPLC,495V-APPLC-BA,49HFV-APPLC-B ,49SVH-APPLC-BA, - C-BA,495VH-APPLC,49HFVH-APPLC,49SV-CWF 49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mountedSpeaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW BA,495V-WRF and 49HFV-WRF True Alert ES, Addressable wall mounted Speaker/S robes. Models: 4950-APPLC, 49HF-APPLC, 4950-APPLC-BA, 49HF-APPLC-BI,49SO-CW and 49H F-CW True Alert ES, ceiling mounted Speakers. Models: 49S0-APPLW, 49HF-APPLW, 49S0-APPLW-BA, 49HF-APPLW-BA,49S0-WRF and S 49HF-WRF True Alert ES, wall mounted Speakers. Models: 49SVC-CK,49SVC-CRALT,49SVC-CRFI RE,49SVC-CRS49SVC-CRBC,49SVC-CWBC, 49SVC-CWFI RE,49SVC-CRFEU ,49SVC-CRBF,49SVC-CWALT,49SVC-CWBA,49SVC-CRB A,49SVC-CWS,495VC-CWBF and 49SVC-CWFEU True Alert ES, Speaker/Strobe Ceiling Mount Dress Covers. Models: 49SVC-WRALT,49SVC-WRBA,49SVC-WRBC,49SVC-WRBF,49SVC-WRFEU,49SVC-WRFI RE,49SVC-WRS,49SVC-WWALT,49SVC-VWVBA,49SVC-VWVBC,49SVC-WVVBF,49SVC-W WFEU,49SVC-WNFIRE and 49SVC-WNS True Alert ES, Speaker/Strobe wall Mount Dress Covers. Models: 49S0C-CWFI RE,49SOC-CRFI RE,4950C-CRS,4950C-CWS,49SOC-CK,4950C-CR, 4950C-CW,4950C-CWALT and 4950C-CRALT True Alert ES, Speaker Ceiling Mount Dress Covers. 12-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0026:0384 Page 2 of 2 Models: 49SOC-WRFEU,49SOC-WRBF40SOCWRBC,49SOC-WRBA,49S0C-WNS,49SOC-WWFI RE,49SOC-WRBLANK,49SOC-WRFlRE,49SOC-WRS,49SOC-\IWJBA,49SOC-WNBC,49S OC-WWBF,49S0C-W\NFEU,49S0C-WWBLANK,49S0C-WWALT and 4950C-WRALT True Alert ES, Speaker Wall Mount Dress Cover. Models: 49Mp-SVWR,49MP-SWm,49Mp-SOWR and 49MP-SOWN True Alert ES,Back Plates. Models: 49SV-LENS-AMBER,49SV-LENS-BLUE,49SV-LENS-RED and 49SV-LENS-GREEN True Alert ES, Colored Lens Kit. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as signalling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. 12-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordirator Fire Engineering Division S Aroma tq;;Lj SimplexGrinnel SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2019 This license is current and active. All information below should be reviewed. C1 0 -ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Qualifying Individual .... This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2017 Expire Date: 10/01/2018 Workers' Compensation History 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco.Th4 SimplexGrinnell LP 3568 Ruffin Road San 92123 :oomia tqlo P: 8583-9100 SiinplexGrinneli F.- 858-633-9101 Personnel listed on this license (current or disassociated) are listed on other licenses. SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. • 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco .TM