HomeMy WebLinkAbout3172 LIONSHEAD AVE; 100; FPC2018-0289; PermitPERMIT REPORT tCity of Carlsbad Print Date: 02/17/2022 Permit No: FPC2018-0289 Job Address: 3172 LIONSHEAD AVE, # 100, CARLSBAD, CA 92010-4707 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Applied: 08/30/2018 Valuation: $0.00 Lot #: Issued: 09/13/2018 Occupancy Group: Project #: Finaled Close Out: 02/01/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: TACO TRUCK TI -SPRINKLER (21 HEADS) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY ' SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Fft2ot _07 hIATERIAL DATA SUBI**--1177AL TACO TRUCK Ti. CARLSBAD, CA EPIC FIRE PROTECTION, INC. 75 TURTLE POINT WAY SAN N1ARCOS, CA 9209 (7roO)310-0122 FAX(7O)78-055 QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT• PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosertsitive element This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL direction of approving authorities having jurisdiction. The heart of Globes GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. QUICK ESPONSE TECHNICAL DATA PENDENT VERTICAL See reverse side for Approvals and Specifications. -Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) MOM -Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL LPC!CE Lodgement wire - stainless steel • SIDEWALL HORIZONTAL SIDEWALL Bulb seat - copper • Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATiNG/CLASSIFICATiON and COLOR CODING I AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES BU LB COLOR CEILING TEMPERATURE ORDINARY 135°F155°F STC/69°C ORANGE/RED 100°F ' 32°C INTERMEDIATE 175 F1200 F 79 C/93 C YELLOW/GREEN '150!F 661C HIGH 28rF 141'C BLUE 225°F 107 C 4077AIRPARKDRWE, STANDISH, MICHIGAN 48658 989544583 • FAX989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL. CONVENTIONAL (OLD STYLE) SPECIFICATiONS NOMINAL K" FACTOR THREAD SLM LENGTH' FINISHES 2.8 (39 metric) 112" NPT 2 1/4" (5.7cm) 4.2 (59 metric) 1/2' NPT 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 112" NPT 2 1/4' (5.7cm) chrome IM,Ite Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) 8.1 (118 metric) 314" NPT 2 7/16" (6.2cm) Black Polyester" METRIC C0WER510N5 ARE APPRONMATE. 'HOREONTAI, SIDEWALL IS 2 9116'. 'FINISHES AVAILABLE ON SPECIAL ORDER. AVAILABLE AS sUL,w LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAMD, 135-F IS6'F 175-F 207F 28EF we C . re -C VYC-DOB MODEL FACTOR src MEC 79C 'C I4?C MEA 10182.8 G12815 26 LII X X X X X S - - - S GL8215 4.2 UI X S X X S S - - - S UPRIGHT 015615 EN Ll-VOH S S S X S S X S X S 018115 7.6' LWOH S X S X S S - - - S 018116 6,1 LWOH S S X X S S S X X S GLI 28 UI X X S X X S - - - X 0L4331 4.2 LII X X S X S X - - - S PENDENT GLSIRI 5.8 LWOH S X S X S X X S S S GL810I 7.6' LWOH S X X S S X S - - S 01.8156 8.1 LIUIOH S S S 5 5 X X S X X VERTICAL. G1 8.6 LII X S - - - SISEWALLT 018133 El UI X - - - - G128561 2.8 LII 5 S - - - 5 HORIZONTAL GL4DOt 42 UI X S S - - - X SIDEWALL GL56WI 5.6 LWOH 5 5 MXX X X - - S 01.56278 5.6 LWOH - -' X S - 0181271 8.1 LIYOH S - - - - 001411EN110114L GL5624 5.6 LIIIOH .- - S S - (OLD STYLE) GLSI33 El LIttON ISPRINKLERS SHALL BE LASTED AS PER THE REQUIREMENTS OF NFPAI3 AND ANY OTHER RELATED DOCUMENTS, - §IIORIZONTAL SIDEWALL 551119 LISTED FOR DEFLECTOR 6' TO 12' BELOW THE CEILING, FM APPROVED 6' TO N' BELOW THE CEILING. INSTALL IN ACCORDANCE TO 8S5306 AND ANY OTHER RELATED DOCUMENTS. 'PENDENT VERTICAL SIDEWALL CULL. LISTED FORE MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL oUL,. LISTED FOR N' MIN. SPACING. OH ORDINARY HAZARD Lft LIGHT HAZARD 117 NPT GLOBES PRODUCT WARRANTY Globe agrees to repair or replace any of its ore, manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). GLAINUP E FIRE SPRINKLER CORPORATION JUNE2012 CIA; BE FIRE SPRINKLER CORPORATION ORDERING INFORMATION SPECIFY Quantity Model Number Style -Orifice • Thread Sizes • Temperature Finishes desired -Quantity - Wrenches - P/N 325350 (1/2°); P/N 312366 (L.O.) 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248.0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #9 Components: "Temperature rating is 00 Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Seallog Screw ESCUTCHEON PLATE 1/2' 7/16' 111,1 nnml RECESSED Assembly 6 - Deflector" DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON I 7/16' (11,1 mm) I NOMINAL E MAKE-IN iso I 2 150.8 rnml I (34,9 antI WRENC FLATS 1 N 0 DEFLECTOR 2-7/8' 3,O mml Dl CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE I SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant applied to the pipe threads, hand- The TYCO Series TY-FRB, 5.6 K-factor, tighten the sprinkler Into the sprinkler WRENCH NCH RECESS Upright (TY313) and Pendent (TY323) fittIng. USE ONLY Sprinklers must be Installed in accor- Step 3, Tighten the sprinkler Into the END 'A) dance with this section. sprinkler fitting using only the W-Type General Instructions 6 Sprinkler Wrench (Figure 2). With ref- FIGURE 2 Do not Install any bulb-type sprinkler erenco to Figure 1, apply the W-Type 6 W6 -TYPE It the bulb Is cracked or there Is a loss Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH of liquid from the bulb. With the sprin- Torque sprinklers 7 to 14 ft.-lbs. (9,5 to Mar held horizontally, a small air bubble 19,0 Nm). TFPI72 Page 2of4 General FIMM Description The TYCO Series TYIcRB Sprinklers described herein must be installed and maintained in compliance with The TYCO Series TY-FRB, 5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National Sprinklers described in this data sheet Fire Protection Association, in addition are quick response, standard coverage, to the standards of any other autho.'i- decorative 3 m glass bulb-type spray ties having jurisdiction. Failure to do so sprinklers designed for use in light or may impair the performance of these ordinary hazard, commercial occupan- devices. cies such as banks, hotels, and shop- The owner is responsible for main- ping malls. taming their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrec- applicable, is intended for use In areas for or product manufacturer with any with a finished ceiling. This recessed questions. pendant sprinkler uses one of the following: Sprinkler A two-piece Style 15 Recessed Identification Escutcheon with recessed adjust- ment up to 5/8 Inch (15,9 mm) from the flush pendant position. Number (SIN) A two-piece Style 20 Recessed Upright 5.6K, 1/2-NPT Escutcheon with recessed adjust- .........Pendent 5.6K, 1/2-NPT ment up to 1/2 inch (12,7 mm) from the flush pendent position. Technical The adjustment provided by the Data Recessed Escutcheon reduces the azrzrrz'am, to which the fixed aloe drops WRENCH RECESS 6 t PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described In Technical Data Sheet TFP357. Sprin- kler guards and shields are described In Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinklersystems and com-ponents. Improper handling and Installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate ma fire situation or cause It to operate prematurely. Page 1 of 4 Approvals Refer to Table A Maximum Working Pressure 175 psi 112.1 ban 250 psi 117.2 bar)' - The maximum working praxaum cf 26 psI 17.2 bar) only applies to the hating by Under_ Labanato. rite, Inc.(UL). Discharge Coefficient K=5.6 OPM/pai5 (80.6 LPM/bar5i Temperature Rating Refer to Table A Finishee Sprinkler: Refer to Table B Recessed escutcheon: White Coated, Black Coated, Chrome Rated, or Brass Plated Physical Characteristics Frame .............................Bronze Button. .......................0cc/Copper 5esSsg Assembly ... Stainless Steal w/TEFLON Bulb .. .............. ... ... .. ..... ..Glass Compression Screw ................. aronzo Deflector .........................Bronze FEBRUARY 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Uptight (TY313) and Pendant (TY323) Sprinklers are Intended for fire protec- tion systems designed In accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval Is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is tube used for recessed pendent Installations. TFPI72 should be present. The diameter of the air bubble Is approximately 1/16 Inch (1,6 mm) for the 135°F (57°C) and 3/32 Inch (2,4 mm) for the 286°F (141°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 t 14 ft.-Ibs, (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or Impairment of the sprinkler. Do not attempt to compensate for Insufficient adjustment In the Escutch-eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendant Sprinklers must be Installed In accordance with the following Instructions. Step 1. Install Pendant sprinklers in the pendent position. Install upright sprin-klers In the upright position. Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor-dance with the following Instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler Into the sprinkler fitting. Step B. Tighten the sprinkler Into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Step C. After ceiling Installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until Its flange comes In contact with the ceiling. ti,ca Worldwide www.tyco-fire.com Contacts Series TY.FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313( and Pendant (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that It controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation In afire situation. The owner must assure that the sprin-klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-operation in the event of a fire or inad-vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other-wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin-kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa-tion Section.) The owner Is responsible for the inspection, testing, and maintenance of their fire protection system and devices In compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec-ommended to be Inspected, tested, and maintained by a qualified inspec- tion Service in accordance with local requirements and/or national codes. 111 Limited Warranty For warranty terms and conditions, visit www.tyco-flre.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, Indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K,a5.6, Quick Response. (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify") finish, P/N (specify*) Specify: Style 20 Recessed Escutch-eon with (specify") finish, P/N (specify") "Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8" 015. mwi 2-1/4' DIA 2 mm) FACE OF SPRINKLER FITTING 5/8'(15,9 mm) FLUSH 3/8±5/ (9,5.7,9 mm) 7 \ MOUNTING (3,2 mar) SURFACE CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4'(19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIP.. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIP.. FITTING (572 mm( 5/16u1/4" 1/2" (12,7 mm) )7.9e,4 mm) FLUSH /8" MOUNTING/// 7 1! (3,2 mm) SURFACE CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm( Vt'.FRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 TFPI72 Page 3 of 4 Page 4 of 4 SPRINKLER FINISH (5cc Note 7) TYPE TEMPERATURE BULB LIQUID NATURAL CHROME COLOR POLYESTER- FACTOR 135"P (57°C) Orange UPRIGHT 155°F (88°C) Red 175°F (795C) Yellow and 1,2,3,4,5, e - PENDENT (TY323) 200 F (93-C) Green 285°F (1415C) Blue 1/2'°NPT _______________ 135(57°C) Orange RECESSED 155 P168 C) Red PENDENT 175F)79"Ci Yellow (TY323) Fogures 4 and 5b 200F (93C) Green N hand I. Usred by Underwriters Laboratettes. Inc.. lULl as Quick Response Spyrkiere. Listed by Underwriters Laboratories, inc.. for use in Canada (0-SIlas Quick Response Sprinklers. Appnavod by Fetruiy Mutual ResearchCurporailon (FM) as Quick Response Sprinklers. 'PP rocedbyttreCliyotNeoc York ardsrMEU3S4-Oi-C. ydbflppr000d Fa, derails, ccntact TYCO Fire Proieciive Products, Enschede, Netherlands, 1.1.31.53.426-4444/Fax 31-54-420-33774 S. approved by the Loss Pmssaniion Csrtlllcesur 000W 110CR P57.50. oaualnol as Quick R.epoose Sprb,klsr5. 7. Where Pobestar Costed 0prtnklen. are nored Sc SOUL and C-al USied. crc apnirkions are UL and C-UL Listed as Conoeion-yeeisrant SprInklers. a. installed with Style IS )t/2• NPfl 5/6 Total Adjustment Recessed Escutcheon, so applicable. S. Installed ,ilfl Otyto 200/2" NPTi 1/2" 70151 Udlu.ttnent Recessed bscutohson, as applicable. c, Fremeavnd 00000ton only. Ustings and sppr000i. apply locator (Special Order(. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Ne 77 - X(X - 1 IN SPRINKLER I S FINISH 370 5.6K UPRIGHT (1/2" NPr) TY313 371 5.6K PENDENT (1/2 NPT) TY323 Nets.: Us.. "i" 10, ISO 7-1 c000lsdilOn: Ian .u.,nlpie, 77-370-4-175-I TEMPERATURE RATINGS 135°F (57°C) 155°F )e8°C) 175F )79C) 200°F (93°C) 286F (141°C) 1 NATURAL BRASS - PURE WHITE (RAL9010)° POLYESTER - SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL8005) POLYESTER 9 CHROME PLATED a. Eesram Hsmlophore seals only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - -- - PART NUMBER SELECTION eaRn P.5054005 Parkway. Lassdale. PA 194,4411 lst.aheos o1-20staU-O7O0 00 Johnson Scw00eeaarwoeasa,*w4reeenaxt5aOec Controls TFPI8I Page 2 of 6 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. TY3531 (3-mm Bulb) is IlL Listed, C-UL Listed, LPCB Approved (Ref. No. 094a/10), VdS Approved (Cer- tificate No. S 4090007), and NYC Approved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM Ap-proved as Standard Response. Factory Mutual does not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed. C-UL Listed, FM Approved, 12GB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-B) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17.3 bar) by UL, C-IlL and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155"F/68"C Sprinkler with 139"F/59"C Plate 200"F/93"C Sprinkler with 165"F/74"C Rate Discharge Coefficient K= 5.6 GPM/psi"2 (80,6 LPM/bar"2) Adjustment 1/2 inch (12,7 mm) Finishes Seethe Ordering Procedure section. Physical Characteristics Frame ...................Bronze Support Cup... Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel wl Teflon' Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel rDuponl Registered Trademark Design Criteria The Tyco5 Series RFil Concealed Pen-dent Sprinklers are intended for fire protection systems designed in ac-cordance with the standard instal- lation rules recognized by the appli-cable Listing or Approval agency; for example, IlL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Sup- pression & Building Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFil Concealed Pendent Sprinklers are only listed and approved with the Series RFll Concealed Cover Plates having a factory applied finish. 1/2' NPT ASSEMBLY FRAME CAP SUPPORT WITH BULB ROLL FORMED THREADS coMPREssrce SCREW GUIDE PINS (2) I DEFLECTOR (DROPPED DEFLECTOR iLJLj- posmote sPRINKLZRFsupVORT cup ASSEMBLY THREAD INTO II RETAiNER SUPPORT CUP ii WITHTHREAO UN11LMOUNT1NG 'h DIMPLES SURFACES FLUSH WITH H EJECTION cEluNc 1 SPRING SOWER TABS 131 COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Do not use the Series RH! in applica- tions where the air pressure above the ceiling is greater than that below Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler op- eration in a fire situation. Fire Suppression I & Building Products I I Technical Seices: TeL (800) 381-9312/ Fax (800) 791-5500 Entail: techserc@tycofp.com I Series AFil - 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Description Protective Cap Cap is temporarily removed installation and replaced to help The TycowSeries RFII Quick Response protect the sprinkler during ceiling in- (3-mm bulb) and Standard Response statation or finish. The tip of the Pro- (5-mm bulb), 5.6 K-Factor, "Royal tective Cap can be used to mark the Flush It" Concealed Pendent Sprin- center of the ceiling hole into plaster kters are decorative sprinklers featur- board or ceiling tiles by gently push- ing a flat cover plate designed to con- ung the ceiling product against the Pro- ceal the sprinkler. These sprinklers are tective Cap. When ceiling installation optimal for architecturally sensitive ar- is complete, Protective eas such as hotel lobbies, office build- ings, churches, and restaurants. an a ''' ner Assembly is installed. Sprinkler Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ As an option, the Series RFll Standard Response (5-mm bulb) "Royal Hush 11" Identification Support Cup Assembly. The sepera- ble, two-piece assembly design pro- Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. Number (SIN) vides the following benefits: (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas TY3531 - 3 mm bulb Allows installation of the sprinklers where it is desirable to prevent air and TY3551 - 5 mm bulb and pressure testing of the fire pro- dust from the area above the ceiling to faction system prior to Installation pass through the cover plate. of a suspended ceiling or applica- tion of the finish coating to a fixed ________ ceiling. The Series RH! Concealed Pendant Permits the removal of suspended Sprinklers described herein must be ceiling panels for access to building installed and maintained in compliance service equipment without having with this document and with the app/i- to first shut down the fire protection cable standards of the National Fire system and remove sprinklers. Protection Association, in addition to Provides for 1/2 inch (12.7 mm) of the standards of any authorities having vertical adjustment to allow a men- jurisdiction. Failure to do so may impair sure of flexibility in determining the the performance of these devices. length of fixed piping to cut for the The owner is responsible for maintain- sprinkler drops. ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted IMPORTANT with any questions. Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING" that provides cautions with respect to handling and instal- Won of sprinkler systems and com-ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the Sprinkler to fail to operate in a fire situation or cause it to Operate ptnmalu,efy. Page 1 of 6 OCTOBER 2009 TFP181 FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING L OMENS ION C SPRINKLER SUPPORT CUP ASSEMBLY 112 (12.7 —) THREAOED U ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE 77 W,16'to 11116' MANUFACTURER DEFLECTOR COVER PLATE (4.610 IN DROPPED RETAINER POSITION ASSEMBLY I REFERENCE 3/32 (2,4 mm) COVER PLATE L COVER PLATE PROFILE DEPTH DIAMETER DIMENSION 8 DIMENSION A A 3414 inches (82,6 mm) C: 2-3/8 to 2-5/8 Inches (60.3 to 66,7 mm) B: 3/16 inches (4.8 mm) 0:1-3/4 to 2.114 inches (44,51a57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I TFPIBI Page 3 of 6 Page 4 of 6 Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector—supported by the Guide Pins—then drops down to its operational position. The glass Bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Installation The Tyco0 Series RFii must be in- stalled in accordance with the follow- ing instructions. Em Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub-ble should be present. The diameter of the air bubble is approximately 1/16 inch (1.6 mm) for the 155"F/68"C and 3/32 inch (2,4 mm) for the 200"F/931C temperature ratfIngs. Obtain a 1/2 inch NPT sprinkler joint by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19.0 Nm). Higher levels of torque can dis- tort the sprinkler Inlet with consequent leakage orimpairrnent of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendant position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFii Sprinkler Wrench. (Refer to Figure 3.) Apply the RFil Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step S. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system Is considered "Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63.5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate/Re- tainer Assembly, remove and discard the Protective Cap. Verify that the De- flector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, pro- ceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown In Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of Its normal position. It you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting, Care and Maintenance The Tyco8 Series RFII must be maintained and serviced in accordance with the following instructions. Before closing a fire protection sys-tem main control valve for maintenance work on the fire Protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and no- lily, all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion In a fire situation. When properly installed, there is a nominal 3/32 inch (2.4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap Is necessary for proper operation of the sprinkler. It the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap Do not pull the Cover Plate relative to the Enclosure. Separation may result. Replace sprinklers that: are leaking or exhibiting visible signs of corrosion. were modified or over-heated. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint facto- ry-painted Cover Plates. If necessary, replace them with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of afire. Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also. re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement Without re- - instating the Cover Plate/Retainer As- sembly. It a Cover Rate/Retainer As- sembly becomes dislodged during service, replace it immediately. Responsibility lies with sprinkler own- ers for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the ap- plicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. SUPPORT FA CE -, CUP CEIUNG -FNENT SEAL -'EVEL AS co SHOWN .~~VEIIFI ASSEMBLY CLEAN R. SEAL RETAINER PLATE FIGURES OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) TFP181 TFP181 Page 5 of 6 Page 6 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for -and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro-sion, or which have not been installed, maintained, modified or repaired In ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation In connection with the sale of prod- ucts or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incom- plete information supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foreaoina warranty is made in live of any and all other warranties, ex-press or implied. includino warranties of merclsantabilitv and fitness for a particular ouroose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex-tent permitted by law. The Invalidity, in whale or part, of any portion of this warranty Will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: (SIN), (temperature rating from below) Series tEll Concealed Pendent Sprinkler, P/N (specify). 155'F/65'c 200F193'C TY2531 51-792.1.155 51.792-1.200 TY3551 51-790-1-155 51.790-1.200 Separately Ordered Cover Plate! Retainer Assembly: Specify (temperature rating from be- low) Series RFll Concealed Cover Plate with (finish), P/N (specify). 939-FI59'clal 166'F,74c1b1 Brass. ......... 56.792.1.135 56-792.1-165 Ch re, ron .......56.792.9.135 56-792.9.165 Signal White IRAL 903l 56-792.4.135 56-792-4.165 Grey White RAt, 9002) 56-792-0-135 5792.0.165 Pore white (n) (PAL 9010).. 56.792.3-135 56-792.3.165 Cuotonr ........56-792.3-135 56-792-5-165 (a) For use with 155'F/68'C sprin1de. frI For use with 200'F193'C sprinklers. 101 Eastern Hemisphere 0605 only. Sprinkler Wrench Specify: REll Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 58-908-1-001. 02008 - 2009TYCO ARE SUPPRESSION & eull.olNG PRODUCTS, 451 North Cannon Avenue, Lartodalo, Pennsylvania 19446 As the Leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—pLus reliable service. VOL need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information T' 1-1 4" CM NM~ifiafoip-e'siii(inc~eO IIIffii 1• IIIUD ________ CM tL 1111 WYAL water I- •1iIJ1I1i = ory M-1 ________________ w Weight Lift ___ EDDYTHREAD 40 ADVANTAGES: UL listed (US& Canada) and FM approved ASTM A135 and A795 Type E, Grade .A Certified Complies with NFPA-13, 13R and 14 industry-leading hydraulic characteristics CRR of 1.0 and greater All pipe NDT weld tested OTHER BENEFITS/SERVICES: We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard II' bacterial-resistant internal coating Custom length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet, dry, preaction and deluge sprinkler systems The only maker with EPDs (to help earn LEED points). c®us LISTED 4 ONFSA NI [HI. 'S LU rlrr'M r Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily A installed around pipe. (2'/i" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel l.'7tHR? NCH PiPF and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650F Finish - Mil, Galvanized For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size 2 ;2 iHRJ 8 iNCH Pipz Dimensions 'Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/ 2 /8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 3/8 8mm or 10mm 33/s 21/8 400 12 7177 3/8 8mm or 10mm 33/4 21/a 400 13 11/2 3/8 8mm or 10mm 3 /8 2% 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/s 41/ 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 7 /8 51/4 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/3 61/4 1250 66 6 1/2 12mm 10/8 6/4 1250 73 8 1/2 12mm 13'/ 8I4 1250 136 Main Office/Manufacturing Facility 13/i S3Ip;I1 Na, • (I1ij3 Oil 929/0 • P11 909 /3/ /I99 Fax 909./3/ 0330 Customer Ser'jice . 90/ /00 '290 1 0 wwwtolco.com Fig. 98 - Rod Stiffener Size Range - Secures 3/8' thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - Ali Thread Rod Cut to Length res 3/8" thru 7/8' rod in 1" incrTTTnts Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions 'Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 114 8000 7140 360 11/'11630 10370 510 Main 011icelManufaclurincj Facility. 13/9 Srp;ii Avc Coi'ji. 01 1)22/9 • Ph 909 /3/ • ra 909:3/0330 S. Customer Service • 2X3 /90 926/ wwWtO!co,Com APPROVED ! 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 p8008957 GST 20 X 2-1/2 850 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 1.5 -8009925 GST 25-380 X 4 1500 1.5 8022925 SWG 25-380 X 3-1/2 - 4 1500 1.5 —8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 2O X 3 1050 1.5 8141957 SH GST 3O X 4 1500 1.5 8140957 SH GST 20 SS X 3 1050 1.5 8142957 SH GST 3OSS X 4 1500 1,5 X 4 175 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1'75 1.5 X 4 1'75 1.5 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR I X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 8059957 CST 20 X 4 14.75 3000 PSI 8061957 SWC2O X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2 SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-13 Standards. Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds IT! wBuildex www.itwbuildex.com 800-284-5339 SSS26 1 of 3 *1 iI[Ifl'7W MODELV-723 SADDLE LET Gu S ® HOLE CUT SYSTEM MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIP110N VGSO Model V-723 Saddle Let small mechanical tees are available in sizes 1-1/4' through 2-1/7. The Models V.723 mechanical tees provide an easy lake-out of a branch outlet without the need for welding. VGS° Mechanical Tees are manufac- tured at ($09001 certified facilities an am designed to conform toASTM and other standards where applicable. Threads are NPT per ANSI B1.20.1. LISTINGS AND APPROVALS c®us Guide No. V1ZM Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Standard black finish Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, add a "G' suffix to the Model number. Rubber compound EPOM Grade E conforming to ASTM D2000. A)N(NA C606, NSF 61 and tAPM0. 'ULO ar,u OU"b. CHiC FIHWU, Laruun clear conforming lOAOiMfllO3 Grade I (UI-IC nuts and bolts are a silver clrromate color and ISO am gold chromate color) lr.sai. c rq - ..........in F_5 ' , r - Lb-Ftlftrn("- 1.25 x 0.5 1 le 1, a 22 1.61 u-suit 20-fl 09 (320 15) 1301 (48) 1001 1561 (42) (3/ee) (27 301 10.41) 1.250 0.75 1.10 1.87 35 22 1.63 U-Sot 20-22 1.0 1320 201 (30( (46) 1091 (56) 13/eel 127-301 (0.45) 1,25x1 1.18 2,04 3.5 2.2 1.73 U-8e1t 20-20 1.0 1320251 (30) (52) 1091 (56) 1441 (3/8a) (27-30) (0.45) 1.5 00.5 1.10 2.04 3.5 2.2 1.70 U-Box 20-22 0.9 140x 15) (30) 1521 (00) (56) 1481 13/8al (27-30) 10.411 1.5 00.75 1.18 2.04 2.5 2.2 1.79 U-BoO 20-22 0.9 )40x30) (30) (52) 1891 56) (46) (3/9a) 127-301 10.411 1,5e 1 - 1.18 2.04 3.5 2.2 1.69 U-BoO 20-fl 5.9 (40x25) (30) (52) (69) (56) (3/8a) 127-301 10.411 200.5 (to. 15) 1.18 2.30 3.86 2.2 2.07 U-Bn6 20-22 0.9 (30) (59) (59) 1561 (53) (3/8e) (27-301 (0.41) 2e0.75 1.19 2.30 3.88 22 2.07 u-Ben 20.22 5.0 (50020) 1 1001 (59) 1981 1561 (3/00) (27-30) (5.41) 201 1.10 2.30 3.08 2.2 1.97 U-Boll 20-22 1.0 (500251 (30) (59) (90) (56) )50) (3/8o) (27-30) (0.45) 2,000.5 1.18 2.46 4.37 2,2 2.22 U-Son 20-22 1,0 (65n 15) (30) (63) (111) 1561 (57) (3/to) (27-30) (0.45) 2.5n0.75 1.10 2.46 4.37 2.2 2.22 11900 211.22 1.0 (65020) (30) (03) (111) 56) (57) (3/8e) 127-301 (0.45) 2.5o 1 1.18 2.46 4.37 2.2 2.13 " oft 20-22 1.0 (65025) (30) (63) (111) (56) )3/8e) (27-30) (0.45) 'Hole dbrnelein are suggested hole saw diarnetern. ''l Take-out (Center of roe to end of pipe to be engaged) 2 of 3 NGSO HOLE CUT SYSTEM 1000 MODEL V-723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com HOLE CUTTING The hole-cut method of pipe preparation is required when using mechanical lees, mechanical crosses, and saddle-lets. The method of pipe preparation requires the cutting or drilling of a specified hole size on the centerline of the pipe. Always use the correct hole saw size as shown this data sheet and never use a torch for cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16 mm) of the hole should be inspected to assure a dean smooth surface, free of any indenta- tions or projections that could affect proper gasket sealing. The area within the 'A dimension should also be inspected and must be free for dirt, scale or any imperfection that could affect proper sealing or assembly of the fitting. Table 2: Hole Sizes for Mechanical Tees Model V-723 .c sons ' llafl)crti To", H6 1. Sal 00) 1" 10.3/4.1 ' 1.3/16 - 1.114 - 3/112 - 115.20,25) (30) 1321 (80) INSTALLATION NOTES: Use a wrench to hold the threaded outlet in place when installing the Table 3: K-factor of Saddle Lets Tighten the nuts evenly. ___nt Lt K-factorof Saddle-Lets 412 415 415 Do not install sprinkler directly into Saddle-Let with V outlet. U-Bolt Hole Gasket - - Threaded oufle icy :t Sprinkler Figure 1: V.723 Saddle-Let Installation The latest VOS Technical Data can be acessed at trttp:/lwww.nlkinygroupine.cem. Scan to visit our Mobile weboite: 10.f)fii!i.ifa I /tl'tliilirtl I Iqt1;i;4 '-I - Form No. F_110515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 Form No. F_110515 16.12.08 Rev 16.1 (Added K-factor limit table and flow data) 3 of 3 HOLE CUT SYSTEM i'l II[i7f MODELV-723 SADDLE LET 'FIttkJ Ei S MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 6. FLOW DATA Flow test data has shown that the total Formulas for Cv Values: head loss between point A and B for p = u Where: fittings can be expressed in terms of the pressure difference across P CV, a = Flaw (GPM) the inlet and branch. The pressure OP Pressure Drop (psi) difference can be obtained from the relationship below. B—o1ib Q_ x C,Flow Coefficient Form No. F_110515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 (Added K-factor limit table and flow data)