HomeMy WebLinkAbout3137 VIA SIMPATIA; ; FPR2017-0232; PermitPERMIT REPORT icity of Carlsbad Print Date: 01/26/2022 Job Address: 3137 VIA SIMPATIA, CARLSBAD, CA 92009-6083 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: CASCADA AT RANCHO CARILLO HOA -FIRE ALARM TI (BLDG 1) Applicant: BAY ALARM COMPANY 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 (858) 586-3803 Permit No: FPR2017-0232 Status: Closed - Finaled Multifamily Fire Alarm Applied: 06/16/2017 Issued: Finaled Close Out: 08/03/2020 Inspector: Final Inspection: FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov p. ------------- RECEIVED JUN 152017 CARLSBAD FIRE DEPARTMENT Vol CARLSBAD FIRE DEPARTMENT PREVENTION DIVISION 1635 FARADAY AVENUE CARLSBAD CA 92008 760-6024665 Construction Permit Application Form Name of Project: CASCADA at RANCHO CARILLO HOA Address of job site: 3137 VIA SIMPATIA, Carlsbad, 92010 (See attached sheet for addresses) Suite# Building Permit No: CB or Project ID.: Contractor Information Company Name Bay Alarm Comp. Address 8205 Ronson Rd., Ste. F City San Diego State CA Zip 92111 Phone: (618) 718-0186 Fax: E-Mail:dan.anderson@bayalarm.com Contractor License Class and Number C-i 0 #880138 Exp. Date: 06/30/18 Do you currently have a business license on file with the City No No: 1229936 Name: Dan Anderson Signature: Date: 06/15/17 Submit plans and completed permit application to: CARLSBAD FIRE PREVENTION 1635 FARADAY AVENUE CARLSBAD, CA 92008-7314 (760) 602-4665 Fax: (760) 602-8561 flremailccarIsbadca.gov Office Hours are: M-TH 7:30 am. - 5:30 p.m. PST FRI 8:00 a.m. - 5:00 p.m. PST To Schedule an Inspection: For inspections ONLY, please call (760) 602-4660, a minimum of two days in advance. Calls will be returned by the end of the next business day. Inspection Hours are: 6:30 AM - 5:00 PM Re-inspection fees and Hydrant Flow Test fees must be paid a Personnel are prohibited by law from accepting payments in Plan Check status Inquiries: Allow at least 10 business da you when the plans are approved / disapproved. Please include a self-addressed stamped envelope for mail rel If after 10 business days you have not received a communica 760-602-8561 or e-mail us at: firemail@carisbadca.gov FPR20I7-0232 '- 02A2- 3137 Via Simpatia CASCADA @ RANCHO CARILLO HOA BLDG. # ADDRESS STREET 1 3137 - 3150 VIA SIMPATIA f°'i- o23a- 2 3121-3134 VIA SIMPATIAoz'3/ 3 6278 - 6298 VIA TRATO oz / 23 4 6259 - 6272 VIA TRATO ez v' 5 3102 - 3133 VIA PUERTA oz0V 6 3117 - 3126 VIA PUERTA az~,,7 v (32 7 3119-2128 VIA PUERTA oz ,/' 8 tz 9 31433152 VIA PUERTA o'z4oV LZ 10 3155-3164 VIA PUERTA ozfl / 3211 6223-6240 VIA TRATO o-Zv' CJL -L' ejSS p ) \'- 8205 Ronson Rd.. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 Ffr\~-o - I. PROTECTED PREMISE CASCADA AT RANCHO CARILLO HOA 3137-38, 3141-42, 3145-46, 3149-50 VIA SIIvIPATIA CARLSBAD, CA 92009 MONITORING COMPANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-470-1000 California Alarm Operating License Number: ACO28 ifi. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1(800) 470-1000 Contractor License # 880138 Search dmpatarms Powerful-s yst addressable fire Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash Updateable: No more firmware chips to replace Adaptive Technology1M - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XRI50FCIXR550FC SERI ES COMkCAL ARE P. --:'LS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on • Multiple on-board status LEDs XR550 FC • Up to 100 output schedules to control relays and panel outputs Up to 142 two-wire smoke detector or fire initiating zones on • 32 individual reporting areas, with common areas Output Groups: Maximum functionality—Minimum programming Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection XR1 5ODNFC/XRS5ODNFC SYSTEM FEATURES Up to .7 Amps 12 VDC supervised bell output • All above listed System Features Up to 506 fully-programmable Form C relays • On-board Ethernet connection for Network MonitoringTM Serial 3 Digital Dialer or CID reporting to multiple receivers • Customizable check-in time and retry time Eight communication paths between the panel and Central Station • Suitable for multi-site applications where the Internet or Built-in remote or on-site feature upgrade capability LAN/WAN is available 12000 event buffer XR1 5OFC & XR550FC FIRE PANELS The XR1 500FC and XR5500FC provide basic fire monitoring for any single site application. The XR1 5ODNFC and XR55ODNFC panels provide I all the same basic fire monitoring as the XR1 500FC and XR5500FC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL I The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACT. NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. I ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. I KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. I TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PlC for power circuit protection. i1:iI'D] i1 ;MD1 &'J ['1 Ie) I I I [sk'TL'I r I Es]1 12 or 24 VDC I j NAC1 12 or 24 VDC NAC 2 Li Digital SLC I Loop 2 Any expansion device can operate on SLC Loop 1 cr2 Power Supply 505-12 or other 12124VDC UL Commercial Fire Approved Power Supplies 630F Fire Command Center Additional 630F Fire Command Centers Li FLEXIBLE COMMUNICATION The XR1 5ODNFC and XR550DNFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path. the 263C or 26311 provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. I 111 Z-AK 01EFT 7 _7 ---------- - - 7 ---- NOTIFICATION CIRCUIT OUTPUTS EXPANSION The XR150FC and XR550FC Easily add NAC outputs to the XR150FC/ of two SPOT relay outputs and four open XR550FC system. Up to three Class B modules collector outputs. that may be activated by can be mounted within the FACP. Model 865 or zone or system events, by schedule, through 866 Class B NAC Modules may be combined the User Menu or when a card is presented. with a power supply to provide additional 4 Output Groups allow multiple outputs to Amp NAC outputs. Use an 867 on the SLC activate with a single event and/or can be Loop to further expand NAC circuits. assigned to a particular user profile. EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, presignal, cross zoning. or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR1 50FC and XR550FC provide up to 570 zones, programmable for a variety of fire applications. The system provides Class B 12VDC powered zones, two on-board and four on the 715 Module, plus eight panel burglary zones. Up to 60 zones are available on 15 keypad addresses and up to 100 zones are available on each built-in LX_BusTM using Expansion Modules. Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the panel response to fire, burglary. panic and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones; find individual zone numbers, check the LX-Bus for Missing. Overlapping and/or Extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATEABLE The XRI50FC and XR550FC panels accept software updates from a remote location using Remote LinkTM software. When new XR1 5OFC/XR55OFC feature updates release, perform the flash update remotely. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL DISPLAYS For additional flexibility, keypads attached to the XR1 50FC and XR550FC panels can display keypad Status List and User Menu text using multiple languages. The user has the option to select the language to use. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location and other zones can be programmed to display and be monitored at different keypad locations. 12,000 EVENT MEMORY Allows the user to view the last 10,000 door accesses or 2.000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindowsTM. The XR150FC and XR550FC include an interface connection for installers to use to connect a laptop computer. LISTINGS AND APPROVALS Refer to the XR150FC/XR550FC Installation Guide (LT-1297). XR150FC/ XR550FC Programming Guide (LT-1232) and specific compliance Listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. I I X ~ ~ 11 m FUM'D M0 7K, 630F LCD Remote Fire Command EXPANSION MODULES 710 Bus SpLitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion. 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS 263C CDMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (ALL require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module POWER SUPPLIES 505-12/LX 5 Amps @ 12 VDC 505-12L 5 Amps @12VDC 505-12A 5 Amps @12VDC PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521 B/BXT Conventional Smoke. CleanMe 521 LX/LXT Addressable Smoke/Heat, CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18 Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Compatable with Central Station Receivers that accept Standard CID. DD. or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS Two; 1100X Receiver 1100XH High Power Receiver hOUR Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application I SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery I Models Output Rating 365, 366, 368 or 369 Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot I exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: I Material Cold-rolled steel (Red) ORDERING INFORMATION XR1 5ODFC-R XR1 50 Fire Control Panel XR1500NFC-R XR150 Fire Control Panel with Network XR550DFC-R XR550 Fire Control Panel XR550DNEC-R XR550 Fire Control Panel with © I =; II 2500 North Partnership Boulevard Springfield. Missouri 65803-8877 800.641.4282 I dmp.com Designed. Engineered & Assembled in Springfield, Missouri I 6.8 Power Requirements During AC power failure, the XR1 50FC/XR550FC Series panel and all connected auxiliary devices draw their power from the battery. ALL devices must be taken into consideration when calculating the battery standby capacity. The I following table lists the panel power requirements. You must add the additional current draw of keypads, zone expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. — Standby Battery Power Calculations Standby Current Alarm Current XR150FC/XR550FC Series Control Panel Qty 1 x 174mA 174 mA Qty 1 x 217mA 217 mA Relay Outputs 1-2 (ON) Qty _______ 30mA Qty _______ 30mA Switch Grounds 3-6 (ON) Qty _______ 5mA Qty _______ 5mA Active Zones 1-8 Qty _______ 1.6mA Qty _______ 2mA* Active Zones 9-10 Qty _______ 4mA Qty _______ 30mA 2-Wire Smoke Detectors Qty ______ 0.1mA Qty ______ 0.1mA Panel Bell Output 1500mA mA 893A Dual Phone Line Module Qty x 12mA Qty _______ x 50mA 263C CDMA Cellular Communicator Qty x 13mA Qty _______ x 13mA 263H HSPA+ Cellular Communicator Qty x 24mA Qty x 28mA 277 Buzzer Module Qty x 5mA Qty _______ x 5mA 1100X Wireless Receiver Qty x 46mA Qty ______ x 46mA 1100XH Wireless High Power Receiver Qty x 160mA Qty _______ x 160mA 860 Relay Output Module (one relay active) Qty x 34mA Qty _______ x 34mA All four relays active 138mA 138mA 865 Style V or Z Notification Module Qty x 26mA Qty _______ x 85mA 866 Style W Notification Module Qty x 45mA Qty _______ x 76mA 867 LX-Bus Style W Notification Module Qty x 30mA Qty x 86mA 869 Dual Style D Initiating Module Qty x 25mA Qty _______ x 75mA 630F Remote Fire Command Center Qty x 63mA Qty x 92mA 7060/7160 Thin line /7060A Aquatite Keypad Qty x 72mA Qty ______ x 80mA 7063/7163 Thinline/7063A Aqua lite Keypad Qty x 85mA Qty _______ x lOOmA 7070/7170 Thinline/7070AAqualite Keypad Qty x 72mA Qty _______ x 87mA Active Zones (EOL Installed) 1.6mA Qty ______ x 2mA* 7073/7173 Thinline/7073AAqua[ite Keypad Qty x 85mA Qty _______ x lOOmA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7872 Graphic Touchscreen Keypad Qty x 145mA Qty ______ x 215mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7873 Graphic Touchscreen Keypad Qty x 143mA Qty x 243mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 734 Wiegand Interface Module Qty x 15mA Qty x 15mA Active Zones (EOL Installed) Qty x 1.6mA Qty x 2mA* Annunciator (ON) Qty _______ x 20mA 734N Wiegand Interface Module Qty _______ x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA Wiegand Reader Qty x 200mA Qty _______ x 200mA 734N-WiFi Wiegand Interface Module Qty _______ x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA Wiegand Reader Qty x 200mA Qty x 200mA Copy Sub-Totals to next page Sub-Total Standby mA Sub-Total Alarm ______mA *Based on 10% of active zones in alarm. I Digital Monitoring Products XRI50FC/XR550FC Series Installation Guide 10 6/5/14 DMP Commercial Fire UL listed control panels WILL NOT display a GROUND FAULT MESSAGE but rather a trouble condition on the LCD display. For DMP Commercial Fire UL listed control panels, Ground Faults are annunciated locally at the LCD display and transmitted to the Central Monitoring Station as a trouble condition as required. See the following. UL 864 Control Units and Accessories for Fire Alarm Systems 3.46 GROUND FAULT - A circuit impedance to ground sufficient to result in the annunciation of a trouble condition. I NFPA722OIO 23.5 Performance of Initiating Device Circuits (lDC) 23.5.2 An open or ground condition shall result in the annunciation of a trouble signal. 23.6 Performance of a Signaling Line Circuit (SLC) 23.6.2 An open, short circuit, or ground fault shall result in the annunciation of a trouble signal. 23.7 Performance of Notification Appliance Circuits (NAC) 23.7.2 An open or ground condition shall result in the annunciation of a trouble signal. Terry Shelton, MBA I Director of Technical Design Digital Monitoring Products I dmp.com 417.831.93621 Fax 417.447.9698 2500 N. PARTNERSHIP BLVD, SPRINGFIELD, MISSOURI 65803-8877 P-417,831,9362 8005414282 F-880,7835724 wwwdrnc',com XR550 and 263H HSPA+ Shown with 383 Rubberduck Antenna. XT30 and 263C COMA Shown with 383 Rubberduck Antenna. (Not to scale) ion (Dt7 (D 0o ------------ SIGNAUNG --------------- FDNY LISTED LISTED - --- Tour Source for Cellulw Solutions The switch is on to cellular for many reasons. In isolated Locations, cellular may be the best primary communications path option. Where land lines could go down, cellular provides a reliable backup path. In critical installations where you need to eliminate the risk of cut phone or network lines, cellular is the solution. Whatever your need. DMP has the technology to create reliable panel-to-central station digital cellular communications. Direct cellular communication enables a direct path for alarm signals from the panel to the monitoring station Uses digital cellular CDMA or HSPA+ data networks in the US and Canada Transmits email and SMS status messages to multiple recipients I SYSTEM FEATURES Modular add-on to XT or XR Series Panels Plug-and-play installation and activation of add-on communication modules Power from panel or separate power supply, with low current draw for long standby battery life Fully supervised to ensure the health of communication DMP Adaptive TechnologyTM switches communication paths while maintaining supervision if the current path becomes unavailable on the XR SerieSTM panels Direct reporting to any DMP Central Station receiver with no relaying or intermediary retransmission of alarm signals Can be equipped with local or remote antenna Check signal strength indication at the keypad MyAccessTM Messaging features, including text message alerts from the panel, and ability to send commands to the panel via text messages Supports the DMP App XR500E/XR550E provides privacy for your data with DMP encryption technology XR1 OOFCIXR500FC and 463C have FDNY approval for network or cell primary communication 1 I j PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and economical options of digital cellular communication. For commercial fire applications, the 263C/263H/463C can be used as a stand- alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Or, use your cellular communicator as a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut orcompromised. The battery backup provides continued communications even when power is lost. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones. Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable. Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The checkin frequency and programming for a backup path adapt to the checkin programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the CDMA or HSPA+ wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP Central Station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Cellular Service from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, the unit is ready to use the SecureCom service. After installing the panel or card. activate the unit via Remote LinkTM. After programming the panel. Remote Link recommends the optimum data plan based on the level of security, desired communication path configuration, and specific programming for the account. REMOTE CONTROL VIA MY ACCESSTM: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel. Residential and smaller commercial users can now remotely control their systems. including the ability to arm /disarm, control outputs. retrieve system status, and perform automation functions. Each command received by the panel is acknowledged back to the user via return SMS Message. Use any model of cell phone for MyAccess Messaging. REMOTE CONTROL VIA DMP APP The App provides Apple© iPhone and iPad owners, as well as Android users, with the ability to access a number of system functions remotely via cellular connection. As a dealer, the App provides the opportunity to load a company logo into the App. For both residential and commercial system owners, the attractive interface provides fast, easy access to the most commonly used system functions. APP CAPABILITIES At a glance, check system status including programmed areas. 'Armor disarm the system in an instant Select from the Home/Sleep/Away arming options for home systems. Select from the All/Perimeter arming options for office systems Select from Area Arming Options 'Tap any programmed outputs to turn them on or off. Adjust lighting/thermostat/locks Video capability - up to six cameras, remote viewing. XTL SERIES The XTLC (CDMA) is available with on-board cellular which allows for MyAccessTM Messaging Email/SMS message commands to be sent directly to the panel. It is also available with on-board network or WiFi allowing for mobile App Control. This powerful burglary, residential fire, and door access panel provides cellular communication with built-in two-way wireless. I I I 11 263C1263H DIGITAL CELLULAR COMMUNICATOR For existing XI & XR150 I XR350 I XR550 Series panels not originally configured with cellular communications, the 263 Series expansion cards Let you add cellular capabilities. The 263C1263H allows alarm messages to be communicated to an SCS- I R or SCS-VR Receiver over their respective CDMA or HSPA+ networks. It provides a fully supervised alarm communication path over the network. The 263C/263H is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply or battery back-up is needed*. Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263C does not include a SIM card and is activated with the MElD number. All modules are ready for activation with SecureCom Wireless. 463C DIGITAL CELLULAR COMMUNICATOR XR1 00IXR500 Series panel users can plug in the 463C expansion card to quickly and easily incorporate cellular communications. In the panel enclosure, it requires no additional enclosures, power supplies, batteries, cabling or conduit connections—simplicity available only from DMP. It can be equipped with local antenna that attaches to the panel, or where necessary for improved signal strength a remote SMA antenna can be used, offering more installation flexibility. The 463C draws half the current of other comparable units. With the Long standby battery life of the system batteries, the 463C can continue to provide a communications Link for up to 80 hours during a power failure with appropriate standby batteries. The 463C does not include a SIM card and is activated with the MElD number using SecureCom Wireless. 464-263H/464-263C DtG11AL-J CELLULAR COMMUNICATOR The 464-263H or462-263Ccellular modules can be plugged onto the XR1 00/XR500 panel boards to add cellular communications inside the panel enclosure. It requires no additional enclosures, power supplies, batteries, cabling or conduit connections. They can be equipped with a local or remote antenna. *p 381 cable is required for the XR1 501 XR350 I XR550 Series The XR500FC Series Fire panels used with the 463C Digital Cellular Communicator has earned the UL 864 listing when used as the primary path (no backup required) for commercial fire installations per NFPA 72. The check-in and fail time settings are programmed for five minutes. When used as the backup path. the 463C provides the security of a communication link that continues to function, even when Land lines are cut or compromised. This interface works on the CDMA data networks over a variety of carriers in the USA. TECHNOLOGY OPTIONS Selecting the right Cellular Communicator Built-in COMA 263C/263H XT30/XT50 X XR1 00 Series A3C464-263C/464-263H X XR500 Series X XTL Series X XR1 50 1 XR350 I XR550 Series X 263C/263H SPECIFICATIONS I Primary Power 12 VDC from panel Current Draw (263C) Standby 13mA Alarm 13mA I Current Draw (263H) Standby 24mA Alarm 28mA 463C SPECIFICATIONS ' Primary Power 12 VDC from panel Current Draw Standby 22mA Alarm 22mA I 464-263C/464-263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw I Standby 15mA Alarm (Nominal) 48mA Peak (-150mS) 85mA 263C/263H COMPATIBILITY I XT Version 112 or higher & XR1 50 I XR350 I XR550 Series Panels (A 381 cable is required for the XR150 I XR350 XR550 Series) I 463C COMPATIBILITY DMP XR1 00IXR500 Series panels using Software Version 202 or higher 464-263C/464-263H COMPATIBILITY I DMP XR1 00/XR500 Series panels using Software Version 212 or higher ACCESSORIES 381-2 18" Coax Extension I 381-12 12 Coax Extension 381-25 25 Coax Extension 383 Rubber Duck Antenna 386 Wall Mount Antenna Bracket I 387-1 3dB Fiberglass Antenna w/bracket 387-2 2dB Attack Enclosure Antenna 387-3 3dB MEG Antenna I 387-4 4 SMA to N Extension Cable 387-8 8 SMA to N Extension Cable 387-25 SMA TO N CABLE, 25FT. LMR1 95 387-50 SMA TO N CABLE, 5OFT, LMR1 95 I I 11 263C CDMA Cellular Communicator (Verizon) 263C/381-2 CDMA Cellular Communicator w/ 381-2 Cable (Verizon) 463C CDMA Cellular Communicator (Verizon) 263H HSPA+ Cellular Communicator (AT&T. I-Mobile. (263HCAN - Rogers)) 263H/381-2 HSPA+ Cellular Communicator w/ 381-2 Cable (AT&T. 1-Mobile. (263HCAN - Rogers)) 464-263C CDMA Cellular Communicator (Verizon) 464-263H HSPA-I- Cellular Communicator (AT&T. 1-Mobile, (464-263HCAN - Rogers)) LISTINGS AND APPROVALS 263C/263H/463C California State Fire Marshal (CSFM) 263C/463C/464-263C FCC ID: MIVCNNO301 Industry Canada: 4160ACNN0301 263C/463C/464-263C Verizon Certified 263H PTCRB Certified (AT&T) 263H/464-263H FCC ID: RI7HE91ONA Industry Canada: 5131AHE910NA 463C New York City (FDNY COA #6123 & #6145) Underwriters Laboratories (UL) Listed 263C/263H ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarms Units and Systems Accessory ANSI/UL 985 Household Fire Warning ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglary ANSI/UL 1635 Digital Burglar ANSI/UL 864 Fire-Protective Signaling 9th Edition (XR150 I XR350 I XR550 Series Panels only) 463C ANSI/UL 365 Police Station Connect Burglar Alarm Systems ANSI/UL 985 Household Fire Warning System Units ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 864 Control Units for Fire-Protective Signaling Systems 464-263C/464-263H ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units Underwriters Laboratories Canada (ULC) Listed 263H (XR150 I XR350 I XR550 Series Panels only) ULC S304-06 Central Station Burglar ULC Subject-Cl 023 Household Burglar ULC/ORD-C1 076 Proprietary Burglar ULC S545 Household Fire ULC S559-04 Equipment for Fire Receiving Centers and Systems 464-263H ULC/ORD-C1076 Proprietary Burglar ULC S304-06 Central Station Burglar For additional information, access www.dmp.com and select Compliance. 2500 North Partnership Boulevard 800 641 4282 1 dmp corn Springfield. Missouri 65803-8877 Designed. Engineered & Assembled inSpringfield. Missouri f SYSTEM SENSOR® Photoelectric Smoke Detectors System Sensor's /3" series smoke detectors repres significant advancement in conventional detecti The j3 family is founded on three principles: instal ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port in-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Installation ease. The P line redefines installation ease with its plug-in design.This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug in to the base with a simple Stop-Drop 'N • Lock action. Intelligence. il detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. Two-wire i3 detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the P protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent per-foot-obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings & <~> MEA MSFM LISTED APPROVED V approved approved S911 3011446 7272-1200-210 290-01-S 2093 (jY Smoke Detector Specifications Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2W1-B, 4VVT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal .sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0,5 A @ 30V AC/DC SpecificationsPhysical Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) Weight 6.301(178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-1 20°F (0°C-49°C); 2WT-B and 4WT-B: 32°F-1 00°F (0°C-37.8°C) Operating Humidity Range U to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4VVT-B only: 41°F (5°C) Sensitivity 2.50/o/ft. nominal Input Terminals 14-22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off . Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Information 2W-B No 2-wire 130 mA max. limited by control 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA •@ 24V 4VVT-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories I 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader . A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter I I SYSTEM SENSOR' I 12O16 System Senor 3825 Ohio Avenue. St. Charles, IL 60174 Phone 800-SENSOR2. Fax: 630-377-6495 A05-0318 006 - 7/06 - 41676 a CUSTOM DOCUMENT ENCLOSURE Modified Mier BW-106R for Bay Alarm 12"Wx 12"H x4"D Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom SYSTEMOgg RECOI - 'L Additional customization of this enclosure, or assistance in designing a new model, including color and/or graphics, is available by calling oremailing Mier Products, Inc. • Ilk 800-473-0213 I info@mierproducts.com J www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL T - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:0135 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 71578, 715-16: Zone Expanders Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 2631-1: Cellular Communicator *(May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RE Wireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter 1135: Wireless Siren *Rev 04-08-15 gt øri This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator I Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 RATING: 120 VAC, 0.5 A, 60 P42 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-08-15 gt T1, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models 2W-B, 2W1-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division