HomeMy WebLinkAbout2100 COSTA DEL MAR RD; ; FPC2017-0269; Permit4L-City of PERMIT REPORT Carlsbad Print Date: 02/09/2022 Permit No: FPC2017-0269 Job Address: 2100 COSTA DEL MAR RD, CARLSBAD, CA 92009-6898 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 09/21/2017 Valuation: $0.00 Lot #: Issued: 10/06/2017 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: OMNI LA COSTA - AV ADD -FIRE ALARM TI FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 341-7780 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov /t FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL FOR OMNI LA COSTA 2100 COSTA DEL MAR CARLSBAD, CALIF. 92009 FPC20I7-0269 2100 Costa del Mar RD B®5im plEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Four, Class B NACs are standard: LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Upto8 NACs Rated 2 A each for conventional reverse polarity 4009 IDNet 24 VDC notification appliances and providing (-NAC Extender multiple operation modes Can be selected to provide synchronization for Simplex® visible notification strobe flashes EXISTING Capable of controlling TrueAlert non-addressable notification appliances operating with SmartSync two-wire control mode** Input control options: IDNet addressable communications from a Simplex model 4007ES, 4010, 4010E5, 4100ES, or 4100U Fire Alarm Control Panel** Or from one or two conventional 24 VDC NACs with multiple output control options IDNet communications control benefits: . Provides status monitoring and individual NAC control using a single address per 4009 IDNet NAC Extender S . Supports IDNet "Device Level" earth fault location WALKTEST operation is available with either input choice Internal 8 A power supply/battery charger: Charges internal batteries up to 12.7 Ali or up to 18 Ali batteries in external cabinet Provides status monitoring of battery, input power, and earth faults Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/strobes Rated 6 A for "Regulated 24 DC" appliance power Optional 4009 IDNet NAC Extender modules: IDNet Communications Repeater provides Class B or Class A output IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class X Four additional Class B NACs, rated 1.5 A for Special Application appliances; 1 A for Regulated 24 DC appliance power Class A, Two Circuit Adapter Module UL Listed to Standard 864 IDNet communication fiber optic transmitters: o For applications requiring the data integrity available S with fiber optic communications . Available as Class B or Class X Mounts in standard six-gang electrical box External battery cabinet for 18 Ah batteries Optional IDNet I Channel Repeater / \ ' ii \\ LJ / 2-Wire IDNet Communication or Fiber Optic IDNet Communications ar NAC Control It LI IDNet Fiber Optic Transmitter 4007ES, 4010 (shown), 401OES,4100ESor4100U Fire Alarm Control Panel Fire Alarm Control Panel with Conventional NACs 4009 IDNet NAC Extender Connection Reference Drawing rnrTT FTT1TI ADA Compliance. Complying with the notification requirements of ADA (Americans with Disabilities Act) may require more notification appliance power than is available within the fire alarm control panel. When additional power is required, a Simplex 4009 IDNet NAC Extender can provide up to 8 A of NAC power with up to eight, supervised reverse polarity NACs. Location Flexibility. The 4009 IDNet NAC Extender can be mounted close to a compatible dedicated host panel or can be located remotely for convenient power distribution. Multiple operation modes and multiple connection options further increase location flexibility. Additional Information. For additional operation detail and application information, refer to Installation Instructions 574-181 and field wiring diagram 842-068. ULC listed model is 4009-9202CA. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:214 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4100U requires revision 11 software or higher for compatibility. 4010 requires revision 2 software or higher for compatibility. S4009-0002-14 9/2015 IDNet Addressable Communications Compatible. Up to ten (10), 4009 IDNet NAC Extenders can be controlled per 4007ES, 4010ES, 4100ES, or 4100U IDNet communications channel; up to five (5) can be controlled on the 4010 IDNet communications channel. Each output NAC can be individually controlled for general alarm or selective area notification requiring only one point address per Extender. Individual Extender NACs can also be manually controlled from the host panel. IDNet controlled extenders will inform the host panel of troubles via IDNet communications. 4007ES, 4fl1flPS 41flfl1 ni141flflTT control k control ii I nine nt1 'ncy Hardwire Control Applications. For applications where an existing (or new) conventional NAC needs additional power, the 4009 IDNet NAC Extender can be controlled directly from the NAC. Either one or two NACs, from either the same, or from different host fire alarm control panels, can be connected to control the 4009 IDNet NAC Extender output NACs. Multiple control selections provide flexible operation. (Refer to page 4 for more detail.) Alarms from the host panel will activate the four, 4009 IDNet NAC Extender NACs (or optionally, eight NACs) to extend the alarm. . The 4009 IDNet Extender monitors itself and each of its multi-point rules, refer to data sheet S4090-001 1 for details. output NACs for trouble conditions, including earth faults. Extenders wired to conventional NACs will Optional IDNet Repeaters. IDNet communications can indicate a trouble by opening the path to the NAC's be repeated with the optional IDNet Repeater Module or end-of-line resistor, but retaining the ability to respond to with the optional Fiber Optic Receiver Module. Up to 100 alarms. Individual troubles are also annunciated by LEDs of the IDNet channel points can be repeated once (refer to located on the 4009 IDNet NAC Extender main circuit pages 3 and 5 for details). Repeated IDNet communications board. (Refer to page 7 for more diagnostic information.) also support the "device level" earth fault location utility of the host panel. FOR lTFL rtrTi Standard Models Model Description 4OO9-92Ol" 40099202CA* 120 VAC input 4009 IDNet NAC Extender with 4, Class B NACs and 8 A power supply 4009-9301 * ULC listed model 4009-9201 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets as detailed on data sheet S2081-0019 Optional Modules (for on-site installation) Model 4009-9807 Description Additional four point NAC module, rated 1.5 A Special Application appliances; 1 A for Regulated 24 DC appliance power, Class B Comments One maximum 4009-9808 Dual Class A adapter (for two NAC outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater, output is Class A or Class B Select either an IDNet Repeater or a Fiber Optic Receiver as required; one transmitter can connect to one receiver 4009-9810 Fiber Optic Receiver Class B 4009-9811 Class A (IDNet), Class X (fiber) 4009-9805 Red Appliqué for door Select if required 2975-9801 Semi-Flush Trim Kit Beige trim 1-7/16" wide (78 mm), use if required for semi-flush installations 2975-9802 Red trim 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series I End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details S4009-0002-14 9/2015 Battery Selection (select battery size per system requirements) Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC External Accessories (select per system requirements) Model Description 4090-9105 IDNet Fiber Optic Class B operation 4090-9107 Transmitter Class X operation 4009-9801 External battery cabinet for up to 18 Ah batteries, beige S Comments Two batteries are required, 24 VDC operation Requires external battery cabinet, two batteries are required, 24 VDC operation Comments Mounts in six-gang electrical box, refer to page 4 for mounting details 0 S S Connection Example Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements, some wiring is not shown.) IDNet addressable communications channel, 4 .—'shown Class B (Style 4) Output NACs four standard Conventional NAC operation (horns) eight with expansion option - Select conventional or SmartSync operation per NAC 4007ES, 4010, 4010ES, 4100ES (shown), or 41001-1 Fire Alarm Control Panel SmartSync operation (horns and strobes) 4009 IDNet NAC Extender with - Conventional NAC optional internal IDNet Repeater operation (strobes) ff~ Repeated IDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to ten (10) 4009 IDNet NAC Extenders maybe connected per 4007ES, 4010ES, 4100ES, or 4100U IDNet channel, up to five (5) on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables, 3000 ft 4090-9105, Class B (914 m) maximum distance (Style 4) Output Fiber Optic Transmitter NACs r.T = IDNet addressable communications channel Class B (Style 4) or Class A (Style 6), Class B shown 7 95 * ~W Repeated IDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel 4007ES, 4010 (shown), 401 IDES, 4100ES, or4lOoU Fire Alarm Control Panel Lour fiber cables, 3000 ft (914 m) maximum dista 24VDC power for fiber optic transmitters 4090-9107, Class A (Style 7) Output Fiber Optic Transmitter 4009 IDNet NAC Extenders internal IDNet Fiber Receivers NOTE: Up to ten (10) 4009 IDNet NAC Extenders maybe connected per 4007ES, 4010ES, 4100ES, or 4100U IDNet channel, up to five (5) on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one receiver in a 4009 IDNet NAC Extender. S4009-0002-14 9/2015 Hardwire Control Connection Information NAC Input Selections. The 4009 IDNet NAC Extender can be selected to: Track input NAC operation or to provide a locally generated code, selectable per NAC input If selected for local coding, NAC outputs can be either Temporal Coded or 60 Beats/min March Time Coded, one code selection per extender (input NACs must be on continuous with Alarm) Additionally, NAC outputs can be selected to provide the Simplex strobe synchronization signal. This signal will synchronize the flashes of synchronized strobes but will be ignored by free-run strobes and audible devices. (Strobes are for operation by noncoded NACs.) NAC input to NAC output control can be selected for standard and optional NACs per the following table: Conventional NAC Output Operation Options Input A B C NAC 1 NACs I & 2, 5 & 6 NACs 1-4 NACs 1-8 NAC 2 NACs 3 & 4,7 & 8 NACs 5-8 None SmartSync NAC Output Operation Input NAC Control Function NAC 1 Strobe Control i All NAC outputs (1-8) NAC 2 Horn Control The TrueAlert Notification Appliance product line includes addressable and non-addressable operation. Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet NAC Extender: TrueAlert non-addressable models with SmartSync operation allow audible notification to be separately controlled over the same wire pair that controls visible notification 4009 IDNet NAC Extenders can be selected to provide SmartSync operation whether controlled by IDNet communications or conventional NACs IDNet control allows output NACs to be individually selected for conventional or SmartSync operation With NAC input control, all output NACs are selected for either conventional or SmartSync operation Refer to data sheet S4009-0003 for TrueAlert Addressable operation details, contact your local Simplex product supplier for further information on specific TrueAlert notification appliances :n7 'i 7if11r1I .xuiI.] i.i ii Is Up to eight (8) output NACs total; hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input (see Note 1) LL Conventional With hardwire control, IDNet ______ ; " .. )7~ 10 NAC outputs are all Out; conventional or all NACs SmartSync operation INAC Fire Arm Control Panel I with Conventional NACs / i SmartSync operation — I Class A operation, either mode, requires NAC 2 input 4009-9808 Dual Class A Adapter (optional, see Note 1) ---] To additional 4009 IDNet NAC Extenders (up to four (4), 4009 IDNet NAC Extenders per NAC); see Note 2 Notes: For separate audible and visible output NAC control, or SmartSync NAC output operation, two (2) input NACs are required. NAC 1 is "on-until-reset" and NAC 2 is "on-until-silenced." To synchronize strobe flash outputs for up to four (4) 4009 IDNet NAC Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905-9914 for Class B operation, 4905-9922 for Class A operation) or, if available, from a NAC selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 4 S4009-0002-14 9/2015 r11I111 I Blom F-11111101 =R=4 MEFM.MJTT1 MITI 120 VAC Input (4009-9201) 3A@ 102-132 VAC, 60 Hz Input 240 VAC Input (4009-9301) 1.5A @ 204-264 VAC, 50/60 Hz Conventional reverse polarity operation Ratings Hardwire Control from External 5 mA maximum; 16 to 33 VDC NACs, Input Requirements Total Rating 8 A, Special Application appliances 6 A, Regulated 24 DC appliance power 2 A each, Special Application or Regulated 24 DC appliance power Standard NACs Optional NACs 1.5 A each, Special Application appliances (requires 4009-9807) 1 A each, Regulated 24 DC appliance power Simplex non-addressable horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product representative for compatible appliances) Output Ratings Special Application Appliances Power for other UL listed appliances; use associated external synchronization Regulated 24 DC Appliances modules where required Up to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other Strobe Operation 500 mA @ 24 VDC nominal Auxiliary Output Optional Modules Ratings IDNet Repeater Module (4009-9809) Input Power 70 mA @ 24 VDC, system supplied IDNet Input, One Address Maximum distance from IDNet source is 2500 ft (762 m) Repeated IDNet output for up to 100 devices (total IDNet devices not to exceed 250 per channel) IDNet Output Specifications Maximum distance to farthest device is 2500 ft (762 m) Total distance including "T-taps" is 10,000 ft (3048 m) Class A maximum distance is 2500 ft (762 m), no "T" taps Fiber Optic Receiver Modules I C Input Current 4009-9810, Class B, 65 mA t 24 VDC, system supplied 4009-9811, Class X, 80 mA@ 24 VDC, system supplied IDNet Output Specifications Same as those for Repeater Module (see above) Fiber Optic Transmission Distance 3000 ft (914 m) maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 90% RH from 32° F to 104° F (0° C to 40° C) Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Fiber Optic Transmitter Specifications Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B, 30 mA @ 24 VDC 4090-9107, Class X, 35 mA @ 24 VDC Fiber Optic Connections and cable requirements Multimode, graded index, 50/125pm, 62.5/125 pm, 100/40 pm, or 200 pm Type ST connectors 4090-9105, Class B operation, two fiber cables required 4090-9107, Class X operation, four fiber cables required Module Size (with mounting bracket) 6-13/16" W x 3-3/4" H x 1-1/8" D (173 mm x 95 mm x 29 mm) On-board Status Indicators Green LED flashing = transmit Red LED flashing = receive Separate red LED on 4090-9107 = Class X receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft (914 m) maximum Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Operating Humidity 10% to 90% RH from 32° to 104° F (0° to 40° C) Operating Temperature 32° F to 120° F (0° to 49° C) * Metric wire equivalents: 18 AWG = 0.82 mm2; 12 AWG = 3.31 mm2 5 S4009-0002-14 9/2015 4009 IDNet NAC Extender Mounting and Module Placement Information _____ . I Cabinet depth 16-1/4' (413 mm) 4-1/4" (108 mm)'l I A 10-29/32' (277 mm) Door, 5/8" ( - 16 mm) I - thick t 0 o 0 Optional Class A 4009-9807 13-1/2" (343 mm) adapter modules point modu Class © Exposed cabinet II dimension for—I C System Module o semi-flush mount ______________ 1" (25.4 mm), Knockouts for screw o[ ~Fiber DNet repeater or 1-3/8" (35 mm) with or nail mounting holes optic receivJ jj semi-flush trim - I l p -.------------.IGo V - I I I I 12" (305 mm) .1 Battery location, no conduit entry or wiring in I this area (12.7 Ah battery outline shown) Semi-flush trim option - [ Non-power limited wiring area (AC input) 1-3/16" wide (30 mm), i 3/8" (9.5 mm) thick L Wall surface reference for semi-flush mount ' NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail - Optional red appliqué (4009-9805 6 S4009-0002-14 9/2015 O1VAtd1WI LJLJLII1 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information n Surface mount box: Simplex model 2975-9217 (ordered separately) Flush mount masonry box: use 6-gang box, RACO # 960, 2-1/2' deep (64 mm), or RACO #965, 3-1/2' (89 mm) deep, or equal (supplied by others) Flush mount ganged boxes: use 6-gang box, 1-1/2" (38 mm) minimum depth; six, RACO # 400 or equal, (supplied by others) 0 0 0 0 0 0 In n n n n r <=_~<ZZ=:><Z=> CL_~- -. - / o o 0 0 0 0 o o 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown, Class A (Style 7) output 4090-9105, Not shown, Class B (Style 4) output [INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. Six-gang blank cover plate Mulberry Metal Products 97156 or equal (by others) I it.iiIt '4I l.I Power-up Self-Diagnostics. Upon power-up, the 4009 IDNet NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are communicated to the host control panel and are also displayed on diagnostic status LEDs in the 4009 IDNet NAC Extender. When connected via IDNet communications, detailed status information is available at the host. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door Mounted Reference Label. The 4009 IDNet NAC Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. LED Status Indicators are provided for the following: Each NAC (standard and optional) has a dedicated yellow LED that: - During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit - During an alarm, the LED follows the NAC output (on steady or flashing with coded output) Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble(s) will then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. AC power status is indicated by a green LED that is on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. S 7 S4009-0002-14 912015 4009 IDNet NAC Extender Current Calculation Chart Step 1. Calculate Basic Extender Battery Requirements (minus NAC loads) Panel, NAC Options, and Auxiliary Power (underlined model numbers are optional modules) Model Descript ion Supervisory Actual Supervisory Alarm Current Actual Alarm Current C14009-9201 120 VAC input Basic Panel - , 85 mA 85 mA (185 mA / 185 mA 4009-9301 240 VAC input 4009-9807 Additional Four Point NAC 40 mA +_______ 40 mA 4009-9808 Dual Class A Adapter (no additional current) - - - - Auxiliary Power Output (500 mA + (500 mA m aximum) maximum) + [Al] Basic Panel Supervisory Current [SI] Basic Panel Alarm Current = [A2] Sten 2. Calculate IDNet Output Module and Device Current (if used) 4009-9809 IDNet Repeater Select one per Extender 70 mA +_______ 70 mA 40099810* Fiber Optic Receiver, Class B 65 mA 65 mA. 4009981I* Fiber Optic Receiver, Class X 80 mA 80 mA IDNet Devices (connected to Repeater or Receiver above), Total devices Total devices 0.7 mA each, maximum of 100 1x 0.7 mA each + x 0.7 mA each +_______ Module Supervisory Current [S2] = * Note: IDNet Fiber Optic Tran=mtte DNet current is supplied from the h alarm control panel IDNet Module Alarm Current [A3] Maximum Available Current = 8 A* Step 2. Calculate Available NAC Current Subtract Auxiliary Power Output -[AI] - [A3] Subtract IDNet Module Current = [A4] * 8 A for Special Application Appliances; 6 A for Regulated 24 DC Appliances Available NAC Current Step 3. Calculate Actual NAG Loading (Limited to Available NAC Current per Step 2.) NAC Type NAC Circuit # NAC Alarm Current Circuit I +________ Circuit 2 +________ Standard Panel NACS, 2 A maximum per NAC Circuit 3 +________ Circuit 4 Circuit 5 Optional Four Point NAC Module, 1.5 A maximum Special Application rating, Circuit 6 +_______ I A maximum Regulated 24 DC rating, per NAC Circuit 7 +_______ Circuit 8 +_______ Total Actual NAC Load Alarm Current = [A5] SteR 4. Calculate Total Supervisory Current Total Supervisory Current = Basic Panel Current [SI] + IDNet Module Current [S2] A. Calculate Total Alarm Current Total Alarm Current = Basic Panel Current [A2] + IDNet Module Current [A3] + Actual NAC Current [A5] = I TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly pro hi bited. 0 ®S I rn plEx Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4009-0002-14 9/2015 © 2015 Tvco Fire Protection Products. All rights reserved All specificationc and other information shown were current as ofdocument revision dale and are subject to change without notice. S Simplex TrueA!ert Multi-Candela Notification Appliances UL, ULC, CSFM Listed, FM Approved; Visible Notification Appliances with Speaker MEA (NYC) Acceptance* and Multi-Candela Strobe; Non-Addressable I 1UI3.1 Speaker/visible (SN) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash: Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important wall mount installation information on page 4) Wall mount SN features: Housings are available in red or white with clear lens with contrasting white or red "FIRE" lettering Covers are available separately to convert housing color Ceiling mount SN features: Housing is white with clear lens Red "FIRE" lettering is printed on two sides Audible notification appliance (speaker): High quality voice and tone reproduction with taps for ¼, '/2, 1, or 2W, at 25 or 70.7 VRMS Capacitor input for connection to supervised notification appliance circuits Speakers are wired separately from strobe wiring UL listed to Standard 1480 and ULCS541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Strobes are activated from NACs selected to provide Simplex® strobe synchronization signals or from separate strobe Synchronization Modules that are available for Class B or Class A operation Regulated circuit design ensures consistent flash output and provides controlled inrush current UL listed to Standard 1971 and 1JLCS526* Options for wall mounted SNs: Red or white adapters to cover surface mounted electrical boxes Red adapter for mounting to Simplex 2975-9145 boxes Red wire guard * See page 2 for additional listing details and wire guard listings. This product has been approved by the California Slate Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7320-0026:247 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. pipe Wall andbeiIing Mount SNs 7 I'i*i.iFllt1 Multi-Candela lrueAlert SNs with speaker and synchronized strobe provide convenient installation to standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount S/V housings are a one-piece assembly (including lens) that mounts to a 4" square electrical box with extension (see details on page 4). The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount S/Vs also install using 4" electrical boxes with an extension (see details on page 4). Strobe Intensity Selection During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. msIn'pI" S4906-0003-8 5/2014 u Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these S/Vs are activated by NACs that provide the Simplex synchronization format. For additional information, refer to data sheet S4905-0003. I Strnhp Annlkatinn SPlAfinn Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Product Selection Wall Mount Multi-Candela SNs Model Housing I "FIRE" Listings Description Color Lettering Housing Dimensions with Lens 4906-9151 Red I White I I Multi-tapped Speaker with Multi-Candela 7 ¼ H 5W 2 ¼ D I UL & ULC Synchronized Strobe; strobe intensity I (184 mm x 127 mm x 67 mm) 4906-9153 White Red I I selectable as: 15, 30, 75, or 110 candela I Ceiling Mount Multi-Candela SN Model Housing I "FIRE" I Color I Lettering I '4906-9154' White Red 4906-9157 I White I Red Wall Mount SN Adapters Model I Description Listings I Description UL Multi-tapped Speaker with Multi-Candela Synchronized Strobe; strobe intensity ULC selectable as: 15, 30, 75, or 110 candela Dimensions Housing= 7 1/2 (191 mm) diameter, ¼" (13 mm) deep Strobe lens protrusion = 2 ¼" (67 mm) above speaker housing Depth into box = 2 W (70 mm) Dimensions 4905-9946 Surface mount red adapter skirt Required when mounting to surface 7 W H x 5 W W x 3 3/16 " D mounted electrical box, 4" square, (197 mm x 137 mm x 81 mm) 4905-9947 Surface mount white adapter skirt 1 1/2 deep with 1 ¼" deep extension depth with SN = 5 ¼" (149 mm) /16" 4905-9903 Adapter Plate, red, required to mount SN on 2975-9145 8 H x 5 i%" W x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Mounting box, red, for surface or flush mount, requires adapter plate 7 7/s" H x 5 ¼" W x 2 WD 4905-9903 (this box may be available for retrofit applications) (200 mm x 130 mm x 70 mm) Wall Mount SN Replacement Covers Model Description Dimensions 4905-9996 Red SN cover with white "FIRE" lettering 7 1/" H x 5" W x I W D 4905-9997 White SN cover with red "FIRE" lettering (184 mm x 127 mm x 35 mm) Synchronized Flash Control Modules Model Description Dimensions 49059914* Synchronized Flash Module, Class B Epoxy encapsulated with in/out operation 18 AWG (0.82 mm2) wire leads, 1 W W x 2 7Ae" Lx /ie" H 49059922* Synchronized Flash Module, Class A rated for 2 A NAC, requires 5 mA (35 mm x 62 mm x 20 mm) operation for power Wall Mount SN Wire Guard Model Description Dimensions 4905-9998 Wire guard with mounting plate, red, compatible with surface and semi-flush 8 WH x 6 5A6" W x 3 1,4" D boxes (UL listed by Space Age Electronics Inc.) (213 mm x 154 mm x 79 mm) S Ceiling Mount Tile Bridge Model I Description 2905-9946 Tile Bridne Dimensions See diagram on page 4 * Refer to data sheet S4905-0003 for additional flash control module information 2 S4906-0003-8 512014 S/V Specifications Common Environmental 32° to 122° F (00 to 500 C); 10% to 93%, non-condensing at 100° F (38° C) Specifications Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Speaker Specifications Input Voltage 25 or 70.7 VRMS, see Note 1 below PowerTaps !Y4,Y2,1, and 2W Frequency Response Fire Alarm General Signaling I 400 to 4000 Hz 1125 to 12 kHz Wattage Tap 1/4 W 2W 1W 2W UL Listed Models, Reverberant Chamber Test, per UL 1480 76 dBA 79 dBA 82 dBA 85 dBA Speaker Output Wall Mount Models 4906-9151 and 4906-9153, Ratings @ 10 ft (3 m) Anechoic Chamber Test, per ULC-S541 (see Note 1 below) Ceiling Mount Model 4906-9157, 25 VRMS Input per ULCS541 70.7 VRMS Input 77 dBA 80 dBA 83 dBA 86 dBA* 81.6 dBA 84.3 dBA 87.1 dBA* 89.7 dBA* 80.9 dBA 84.1 dBA 87.3 dBA* 90.2 dBA* * NOTE: Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-S541 Attenuation I Angle Attenuation Angle Anechoic Chamber Testing) 3 dB +/- 30° off-axis -6 dB +1- 55° off-axis Strobe Specifications Rated Voltage Range Regulated 24 VDC; 16 VDC to 33 VDC, see Note 2 below Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Housing Dimensions (with lens) 71/4 H x 5" W 2 %" D (184 mm x 127 mm x 67 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents at 18 VDC other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions Speaker housing = 7%" (191 mm) diameter, 1/2 deep (13 mm); lens protrusion above speaker housing = 2 %" (67 mm); depth into box = 2 %" (70 mm) (Ceiling Mount- Maximum RMS Current Rating per Strobe Setting 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA [Reference RMS Currents at 18 VDC r voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: Speakers are for connection to conventional fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. The maximum RMS strobe current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Speaker Directional Characteristics Reference ••••••u••u•u•uu•u•••••uuii•ui•uu•uuu •••••u•uuiuu•uu•u•••••••••u•uuu•••uu •••••••.••..•....................... - . •.....uuu•uuuuu"i•iuu•••uuu••••u•• •••u•umuuuuuuriuu•u••uuuu••u••u•• •••u•uuuu•••a••uuuuuu•i•••••••• • - . . - UUl••••Ud••UU•••••••lUl•uuuu• NNNNNNN•UNUNNRUURNUNlUNNNUUUUUmu I • • - - I. 3 S4906-0003-8 5/2014 Removable requir — IF ~ R15) Ceiling Mount S/V Installation Reference and Tile Bridge Dimensions ~11 "5:~~ O — — ~J ;~~ 1, 4" (102 mm) square, 1-1/2' (38 mm) deep box with 1-1/2 extension (by others) [2905-99461 1/2" (13 mm) [Tile Bridgej 0.024" thick sheet metal, folded with 1/2" lip each side 3-3/4" (95 mm) square cutq centered on plate 1/4" diameter (6 mm) holes, 4 places 13-3/8" (340 mm) Wiring input terminals and accessible from rear of speaker tap selection are speaker housing rr - --. ( jjc1_H viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd ------------------------------- 23-11/16" (602 mm) Wall Mount Installation Reference I IMPORTANTI INSTALLA110N [i] 4905-9903 - Adapter Plate ' ( Standard Electrical Box Mounting 4(102mm) square box, 1-1/2" (36 mm) deep, with a 4" square box / extension, 1-1/2" deep, by others m m/ (1 0 o(). 1 ° ( J ° Jr i Jl - / II 1\----------- 2975-9145 box outline ,_- 4" square box outline + fE }4"(102mm) j 82"(J.lm 11-1/2" (38 mm) minimum NFPA 72 requires that the 78-1/2" (2 m) entire lens be not less than minimum 80" and not greater than 96" above the finished floor. --------------------------- Mounting to 2975-9145 Box 2975-9145 Box Wiring input terminals and speaker tap selection are accessible from rear Speaker assembly Strobe assembly / Intensity selection Transparent plug, accessible only housing and from rear of housing; lens assembly factory setting is 15 cd Strobe intensity viewing slot Surface Mounting Reference Showing Optional Wire Guard Surface mount conduit and box shown for reference 4(102mm) square box profile, 1-1/2" (38 mm) deep with 1-1/2' extension Optional 4905-9998 Wire Guard Surface mount adapter skirt, 3-3/16" (81 mm) deep, required for this mounting method: 4905-9946, Red; 4905-9947, White (conduit knockouts are provided on all four aides) Fn S TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®Si rn pIEX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4906-0003-8 5/2014 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0214 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com EXISTING DESIGN: Models* 4009-9001, 4009-9002, 4009-9101, 4009-9102, 4009-9201-,4009-9301, 4009-9401 Notification Appliance Circuit (NAC) Power Extenders. Refer to listee's data sheet for detailed product description and operational considerations. Unit components: 565-594 Power Supply 565-569 Style Y Signal Card 565-358 Voice Controller Card 562-907 Amplifier Board 565-388 Style Z Signal Card 4009-9807 NAC Option Card 4009-9810 Fiber Receiver 40909105,*9107 Fiber Transmitter 4009-9809 IDNet Repeater 4009-9808 Class A Adaptor 4009-9803-98044 Circuit NAC Card 4905-9929 Isolator Module 4009-9806 Earth Detect Module *40039803 Remote Microphone Module RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The NAC must be fully supervised and must have the secondary power supply capable of operating the system for at least 24 hours (battery standby) in the normal condition and followed by not less than 5 minutes of alarm as required by code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power extender units for use with listee's separately listed fire alarm control units. NOTE: *Rev/Rece 03-29-2006 jw ri, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01,2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-0026:0247 Page 1 of 1 CATEGORY: 7320 -- SPEAKERS LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4903-9356, -9357, -9358, -9359, -9360, -9361 and *Models 4906-9151 and -9153 TrueAlert Non-Addressable *Wall Mount speaker strobes. Models 4903-9196, -9197, -9198 and *Model :4906791547rueAlert Non-Addressable *Ceiling Mount speaker strobes. *Suitable for indoor use only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 25 or 70 V rms, 1/4, 1/2, 1 and 2 Wattage Taps Candela: 4903-9356,-9359,-9196: 15cd -9197: 30cd -9357,-9360: 75cd -9358,-9361,-9198: 1 10c *4906..9151 -9153, -9154: 15cd, 30cd, 75cd, 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number electrical/candela rating and UL label. APPROVAL: Listed as hearing impaired speaker strobes for use with separately listed fire alarm control units. Refer to manufacturer's Installation Manual for details. These devices do not generate a temporal pattern code. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. NOTE: *Rev. 11-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I