Loading...
HomeMy WebLinkAbout3450 GARFIELD ST; ; FPR2019-0115; PermitPERMIT REPORT Lay of Carlsbad Print Date: 02/10/2022 Job Address: 3450 GARFIELD ST, CARLSBAD, CA 92008-3238 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2041500603 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: PACIFIC VIEW VILLAS -NEW FIRE ALARM FOR 3 UNIT CONDOS Applicant: FIRE ETC FRANCHOT DAVIS 2190 MAIN ST SAN DIEGO, CA 92113 (760) 859-7443 Permit No: FPR2019-0115 Status: Closed - Finaled Multifamily Fire Alarm Applied: 05/28/2019 Issued: 07/01/2019 Finaled Close Out: 12/05/2019 Inspector: Final Inspection: FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov z 0 U- 15 ry w IL IoI - ' UJi --J .15 0) C N' D 0 o IL ..< Li.. c') i- THREE UNIT CON DOMINUM 3450 GARFIELD STREET CARLSBAD, CA 92008 FIRE ALARM SYSTEM CONTRACTOR FIRE ETC. 2190 MAIN STREET SAN DIEGO, CA 92113 PH: (760) 672-5914 CA LIC. C10-1028927 TABLE OF CONTENTS ITEM QTY 1 1 2 1 3 2 4 5 5 I 6 I 7 2 8 1 9 9 10 A/R 11 A/R PART # DESCRIPTION SK-6700 Addressable Fire Alarm Control Panel CELL-CAB-SK Cellular Fire Alarm Communicator NP7-12 Battery 12 Volt, 7.0 Amp/Hr. SK-Minimon Addressable Mini Monitor Module SK-PHOTO-W Addressable Smoke Detector SK-HAET-ROR Addressable Rate-Of-Rise Heat Detector B300-6 Detector Mounting Base, 6" SK-Pull-SA Addressable Pull Station MHW Mini-Horn • 18/2 FPL Fire Cable • 16/2 FPL Fire Cable MANUFACTURER Silent Knight Silent Knight Genesis Silent Knight Silent Knight Silent Knight Silent Knight Silent Knight System Sensor Genesis Cable Genesis Cable 6700 Addressable Fire Alarm Control Pat Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensors (SK) sensors and 50 SK modules or 50 Hochiki (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. [J The 6700 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS Capable of providing up to 100 points to satisfy smaller installation needs Connect up to 17 panels on one site with convenient single- point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models Convenient field-u pgradeabte firmware Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting 6860 annunciator with a 4x 40 large display Four user- programmable buttons minimize time spent executing complex or routine tasks Built-in USB interface for convenient and quick programming Programmable date setting for automatic and convenient Daylight Saving Time changes JumpStart auto programming reduces installation time 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with N FPA 72 calibration testing requirements. INDICATOR LIGHTS GeneralAtarm (Red): Flashes if in alarm; solid when alarm is silenced Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4-to 7-digit operator's code. PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart® auto programming minimizes programming required to start a new system. The built-in keypad, orthe 6860, 5860 or 6855 remote annunciators give you on-site access to current system programming. Programming can also be accomplished using the Windows-based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windowse software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running MicrosoftWindows. ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray: 5860R is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES Seethe data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614,350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. UL Listed: S2766 CSFM 7165-0559:0501 FONY COA# 6250 Page 2 of 4— 351607:13 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (1351F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1901F), white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PH OTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B300-6(4V): 6" base for SK-W Series B21OLP: 6" mounting base B501(-8L-IV,-WHITE): 4"flangeless base B501:4" Flangeless mounting base B200S(-IV,-WH): Intelligent sounder base B200S: Intelligent sounder base B200S-LF(-IV,-WH): Low-Frequency intelligent sounder base 8200S-LF: Low-frequency intelligent sounder base B224RB(-IV,-WH): Relay base 8224RB: Relay base B224B1(-IV,-WH): Isolator base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61 B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base S0505-6SB: Addressable 6 sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the 5D505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. S0505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F (0°C-37°C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime H RL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and B51OW 4' base WSK-HEAT: Wireless Heat, (1351F fixed temperature) and B510W4' base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and BSIOW 4' base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL-MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet Requires a VisorAlarm receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16"W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4— 351607:B 9/26/2018 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) Flexputa, Honeywell', Overall Dimensions: 12 71W 15.12 H 3 33 D Two programmable circuits which can be Jump5t®, Silent Knight®, SWIFT®. and System programmed individually as: Weight: 15 tbs. NACs:2.54@ 27.4VDC per circuit, power-Limited Sensor' trademarks of Honeywell Color: Red (with a panel maximum current of 2.54) International Inc. ENVIRONMENTAL Auxiliary Power Circuits: 2.54 @ 27.4VDC per Hochiki® isa registered Operating Temperature: 32°F to 120°F (0°C to circuit, power-limited trademark of Hochiki 49°C) Corporation. Microsoft Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) and Windows® are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING: See the product manual for wiring details This document is not 6700 Primary AC: 120 VAC @ 60 Hz, 1.54 Total intended to be used for installation Accessory Load: 2.54 @ 27.4 VDC power-limited purposes We try to keep our product Standby Current: 165mA information up-to Alarm Current: 310mA date and accurate. We Battery Charging Capacity: 7 to 354H cannot cover all specific Battery Size: 7AH max. allowed in control panel applications or anticipate all requirements All cabinet. Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet, to change without notice. ForTechnical Support, call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 Honeywell 800-328-0103 351607 I B I 09/18 SILENT www.silentknight.com © 2018 Honeywell International Inc. 4 KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0501 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett©honeywell.com DESIGN: Silent Knight Model 6700, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model 6700 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card 5K-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"VVXI0"HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: I20VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0501 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CELL-CAB-SK Honeywell Fire Alarm Communicators DSILENT KNIGHT CELL-CAB-SK and CELL-MOD Cellular Fire Alarm Communicators The CELL-CAB-SK and CELL-MOD are cellular communicator options for the Honeywell Silent Knight 6000 Series addressable fire alarm control panels (FACPs). These GSM communicators provide cellular communication as an alternate method of central station reporting. Combined with the FACP's onboard communicator, they provide dual path cellular and IP reporting capability, while eliminating the need and cost of separate dialer capture modules and special programming. Battery backup from the control panel maximizes overall system efficiency. Small size, easy to install, with a programmable supervision time of 1-60 minutes, these communicators can be positioned remotelyfrom the fire alarm control panel via 4-wire serial bus for optimum reception. The CELL-CAB-SK and CELL-MOD are UL 864 and NFPA 72 fire code compliant for sole, primary, and backup communications. They work with AlarmNet to provide a UL-listed connection to the central station. The CELL-CAB-SK includes a GSM communicator within a metal cabinet enclosure with lock and key and includes an external antenna. The CELL-MOD houses the GSM communicator in a plastic enclosure and has an option for an external antenna. FEATURES & BENEFITS Communicate directly with Silent Knight 6000 Series fire alarm control panels Battery backup provided by the panel to increase system efficiency and decrease cost UL 864 and NFPA72 code compliant for sole, primary, and backup communications Remote mounting up to 6,000 ft (1,828.8 m) Quality of Service (QOS) diagnostics via 4tarmNet convey vital communicator information such as when messages are received, signal strength, and message path used Programmable supervision time from 1-60 minutes Provide full data reporting using Contact ID format Easy installation -no need for special • Provide dual-path • Easily managed programming or cellular and IP accounts through separate dialer module reporting capability on-line management tools CELL-CAB-SK and CELL-MOD Technical. Specifications PHYSICAL HSPA+ (413) and HSPA (HSDPA & HSUPA) (3G) A[armNet, Honeywell', and CELL-MOD: 1.809"W x 5.982"H x 1.5D COMPATIBILITY Silent KnightO are registered trademarks of Honeywell (19.83cm x 15.19cm x 3.81cm) The CELL-CAB-SK and CELL-MOD are compatible with International, Inc. CELL-CAB-SK: 10.38"W X 10.165H X 3.176"D the following Honeywell Silent Knight F4CPs: This document is not intended (26.37cm x 25.82 cm 8.07cm) 6820: addressable FACP with up to 1,110 points to be used for installation SHIPPING WEIGHT 6820EVS: addressable fire alarm control panel with up purposes. We try to keep our CELL-MOD: 1.3 lbs (589.7 g) to 1,110 points and an emergency mass notification product information up-to- date and accurate. We cannot CELL-CAB-SK: 5.2 lbs (2.36 Kg) system cover all specific applications 6808: addressable FACP with up to 198 points or anticipate all requirements. ENVIRONMENTAL 6700: addressable FACP with up to 100 points Alt specifications are subjectto Operating Temperature: 320F-1201F (0°C-49°C) ORDERING INFORMATION change without notice. Humidity: 10-93% relative humidity (non-condensing) CELL-CAB-SK: Cellular module housed in a red, metal ELECTRICAL cabinetwith lock and key. Includes external antenna Standby Current: 55m4 CELL-MOD: Cellular module housed in a red, plastic Alarm Current: lOOmA enclosure. (External antenna sold separately) CELL-ANTENNA: 3dB gain external/remote antenna RADIO TRANSCEIVER APPROVALS 313 Cellular Radio UMTSWCDMA FDD 850/1900MHz UL-Listed FCC part 15, 22, 24, and 68 compliant CSFM Approved FCC ID: CFS8DLPHS8-US COMMUNICATION PROTOCOLS Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 Honeywell 203.4847161 3516271 C iiiis ?SILENT www.silentknight.com ezola Honeywell International Inc. U KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0516 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: Model Cell-CAB-SK cellular transmitter consists of a metal enclosure and a cellular transmitter. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a cellular transmitter for use with separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 01-07-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: January 08, 2019 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Intelligent Mini Monitor Module The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels (FACPs). The SK- MINIMON acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-MINIMON supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. INSTALLATION The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and Lightweight allow itto be installed without rigid mounting requirements. SK-MINIMON FEATURES & BENEFITS Single contact monitor Rotary address SK-Minimon support switches for fast for Class B (Style B) installation contact monitor wiring UL Listed Small and lightweight CSFM Listed size allows for flexible FM Approved mounting options SK-MINIMON Technical Specifications PHYSICAL Dimensions: 2.75"Wx 1.3" H x0.5" 0 Weight: 1.2 oz (37 g) ELECTRICAL Operating Voltage: 15— 32V0C SLC Standby and Alarm Current: 350 pA End-of-Line Resistance: 47K Initiating device circuit wiring resistance: 1,500) max SLC loop resistance: 40) max Wire Length: 6 mm. ENVIRONMENTAL Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10°/c - 930/0 non-condensing ORDERING INFORMATION SK-MINIMON: Mini monitoring module COMPATIBILITY The SK-MINIMON is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ForTechnical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 350133l Rev GI11/17 C 2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett©honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, lOP-Monitor, lDP-Minimon, lOP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, lOP-Relay, 5K-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. Anew modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. SK-PHOTO-W FEATURES & BENEFITS New modern profile for improved aesthetics Stable communication technique with noise immunity Low standby current Two-wire SLC connection Optional remote, single- gang LED accessory Dual LED design provides 3601 viewing angle Remote test feature from the panel Built-in functionaltest switch activated by external magnet Built-in tamper- resistant feature Sealed against back pressure Expanded color options SEMS screws for wiring of the separate base Optional relay, isolator, and sounder bases Plugs into separate base for ease of installation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document 405-1003, is available at system sensor.com INSTALLATION The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B") wiring. When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector, white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DN R(W) duct smoke detectors, white. SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES 8300-6: White, standard flanged low-profile mounting base. B300-6-BP: Bulk pack of 3300-6, package contains 10. B300-6-IV: Ivory, standard flanged low-profile mounting base. 8501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangetess mounting base. UL listed. 8501-IV: Ivory, standard European flangeless mounting base. UL listed. B200S-WH: White, Intelligent, programmable sounder base. B200S-'IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. 8200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. 8200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. 8200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B22481-WH: White, plug-in System Sensor isolator detector base. B22481-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RA100Z: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL Height: 2.0(51mm) installed in 8300-6 base Diameter: 6.2(156mm) installed in B300-6 base 4.1(104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 32°F to 122°F (0°C to 50°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) UL listed Velocity range: Photo/Photo with Thermal: 0 to 4,000 fpm (0 to 20 m/sec) (suitable for installation in ducts) Humidity: 100/0 to 93% non-condensing Thermal Ratings: Fixed Temperature Set point: 135°F (57°C) ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Operating Current @ 24VDC: 2001A (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). COMPATIBILITY The SK-PHOTO-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL Listed: S6173 FM approved CSFM: 7272-0559:0523 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation, Silent Knight", System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Joe 3516341 Rev 104/18 182018 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL F FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0512 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURlTYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models IDP-PHOTO-W, lDP-PHOTO-R-W, lDP-PHOTO-T-W, SK-PHOTO-W, SK-PHOTO-R-W, and SK-PHOTO-T-W analog addressable, photoelectric smoke detectors for open area and duct installations. Models IDP-PHOTO-T-W and SK-PHOTO-T-W have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0503 02-06-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5K-H EAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-HEAT-W Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 1351F/570C fixed temperature, rate-of-rise and a 190°F/880C fixed high-temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. SK-HEAT-W FEATURES & BENEFITS Sleek and stylish contemporary design Advanced thermal technology for fast response Fixed temperature model (SK-H EAT-W) factory preset to 135°F (57°C) Rate-of-rise model (SK-HEAT-W-ROR), 15'F (8.3'C) per minute High temperature model (SK-H EAT- W-HT) factory preset to 190'F (8810 Addressable by device Two-wire SLC connection Visible LEDs "blink" every time the unit is addressed Built-in tamper- resistant feature 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identification Remote test feature from the panel Built-in functional test switch activated by external magnet Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) Low standby current Designed for directsurface or electrical box mounting Sealed against back pressure Plugs into separate base for ease of installation and maintenance SEMS screws for wiring of the separate base Optional remote, single- gang LED accessory APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of property. For further information, refer to manual 56-6541, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector Mount base (at( base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "1-taps" or branches are permitted for Style 4 (Class "B") wiring. When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. ORDERING INFORMATION SK-HEAT-W: Thermal heat detector, 1351F fixed, white. SK-HEAT-ROR-W: Thermal heat detector, 135°F rate of rise, white. SK-HEAT-HT-W: Thermal heat detector, 190°F high temp, white. 8300-6: White, standard flanged low-profile mounting base. 8300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged low-profile mounting base. B300A-6-IV: Ivory, standard flanged low-profile mounting base. UL listed. B501-WH ITE: White, standard European flangeless mounting base. UL listed. 8501-BL: Black, standard European flangeless mounting base. UL listed. 6501-IV: Ivory, standard European flangeless mounting base. UL listed. B200S-WH: White, Intelligent, programmable sounder base. B200S-IV: Ivory, Intelligent, programmable sounder base. 8200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. 8200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B22481-WH: White, plug-in System Sensor isolator detector base. B224B1-IV: Ivory, plug-in System Sensor isolator detector base. CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RA100Z: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory.. SK-HEAT-W Series Detector Technical Specifications PHYSICAL Height: 2.0(51mm) installed in 8300-6 base Diameter: 6.2" (156mm) installed in B300-6 base 4.1(104 mm) installed in 8501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Heat -Fixed temperature: -4°F to 100°F (-20°C to 38°C) Heat -Rate of Rise (ROR): -4°F to 100°F (-20°C to 38°C) Heat -High Temperature: -4°F to 1501F (-20°C to 66°C) Humidity: 10% to 93% non-condensing Thermal Ratings: Fixed Temperature Set point: 1350F(570C) Rate-of-Rise Detection: 150F/mm. (8.30C/mm High Temperature Heat: 190°F (881C)Electrical Ratings ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 4.5m4 ® 24 VDC (ON"). COMPATIBILITY The SK-HEAT-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S2101 FM Approved CSFM: 7270-0559:0511 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation, Silent Knighte, System Sensor' and Honeywell" are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 351637 1 Rev A 104/18 © 2018 Honeywell International Inc. L't CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Il. 6- - LISTING SERVICE LISTING No. 7270-0559:0511 Page 1 of 1 CATEGORY: 7270 - HEAT DETECTOR LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: Models IDP-HEAT-W, IDP-HEAT-HT-W, SK-HEAT-W, SK-HEAT-HT-W (fixed temperature) and lDP-HEAT-ROR-W, SK-HEAT-ROR-W (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models IDP-HEAT-W and SK-HEAT-W (fixed temperature): 135°F. Models lDP-HEAT-HT-W and SK-HEAT-HT-W (fixed temperature): 190°F. Models lDP-HEAT-ROR-W, SK-HEAT-ROR-W (fixed temperature with rate of rise): 135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B7IOLP (CSFM#7300-0028:173); System Sensor bases 8510, B2IOLP, 13300-6, B300-6-IS (CSFM#7300-1653:0109); B224B1, B224RB (CSFM#7300-1653:0126); B200S, B200SR (CSFM#7300-1653:0213); B200S-LF, B200SR-LF (CSFM#7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0502 02-06-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[131) Shell, door, and handle molded from durable LEXAN Reliable analog communications for trouble-free operation Braille text on station handle Rotary address switches for fast installation Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled UL Listed, including UL 38, Standard of Manually Actuated Signaling System CSFM Listed MEA Listed SK-PULL-SA I SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double gang or4" (10.61 cm) square electrical box. You can also use the optional (System Sensor PN BG-TR) trim ring if the station is being semi-flush mounted. SK-PULL-SA SK-PULL-DA FEATURES & BENEFITS Installer can open Key operated test and station without reset lock using lock causing an alarm plate actuator condition Key matches Dual-color LED is compatible FACP visible through handle locks of station blinks green Meets ADA to indicate normal requirement for 5 Lbs operation and remains maximum pull force to steady red in an alarm active condition SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions: 5.5"H x 4W x 1.45" 0 (14 x 10.2 x SK-PuLL-SA: Single Action Pull Station 3.7cm) SK-PuL(-DA: Dual Action Pull Station Microsoft, Windows, and the Windows Logo are Housing Material: LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green: Normal BG-TR: Optional trim ring. Microsoft Corporation. Steady Red: Alarm SB-I/O: Surface backbox, indoor/outdoor. Silent Knighte, System Switch: Single pole, single throw (SPST) normally * Unless otherwise noted, specifications apply to Sensor' and Honeywell' open (N/0) switch which closes upon activation of SK-Pull-SA and SK-Putt-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International, Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage: 15— 32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current: 350pA Knight fire alarm control panels: installation purposes. We Wire Gauge: Up to 12AWG (3.1 mm2) 6820: Addressable fire alarm control panel try to keep our product information up-to 6820EVS: Addressable fire alarm control panel date and accurate. We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature: 32°F - 120°F (0°C - 6808: Addressable fire alarm control panel applications or anticipate 49°C) 6700: Addressable fire alarm control panel all requirements. All Humidity: 10% - 93% non-condensing 5700: Addressable fire alarm control panel specifications are subject to change without notice. 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel For Technical Support, call 800-+46-6444 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 Doc 3501351 Rev El 11/17 9 SILENT 800-328-0103 © 2017 Honeywell International Inc. l! KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0161 Page 1 of I CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneyweII.com DESIGN: Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to Iistee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-0028:0199 04-16-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR ID Mini-Horns The SpectrAlerto Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Features 12 and 24V operation High and low volume settings Temporal and non-temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series MiniAlertTM sounders Listing for ceiling or wall mounting Agency Listings @ <~, (g LISTED APPROVED S4011 3028007 CSIORR 7135-1653198 SpectrAlert® Advance Mini-Horn Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. IPhysical 1ISpecifications Dimensions 4.61. x 2.9W x .451D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23A" deep) Flush: Standard 4"x 4-back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24D0/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8-17.5VDC 8-17.5VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information MHR Mini-Horn, Red MHW Mini-Horn, White e2O2System Sensor. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Product spec f caoons subject lot change without notice. Visit oystemuenaor.com SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product Information.inhuding the latest nersiorn of this data Street. AVDS01 500 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0196 Page 1 of I CATEGORY: 7135— AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models MHR, MHW and APAI51 horns. The Model APAI5I is a remote sounder intended to be connected to the alarm indicating circuit of listed duct smoke detectors. All units are for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: APAI5I: Regulated 24 VDC Operational 16-33 Volts, 30mA MHR and MHW: Regulated 12V DC/FWR and 24V DC/FWR Operational 8-17.5 and 16-33 Volts, 18mA at 12V and 30mA at 24V Audibility: MHR and MHW Tones 1, 2, 3 & 4 are Public Mode at 24V DCIFWR Tone 3 is Public Mode at 12V DC Tones 1, 2 & 4 are Private Mode at 12 V DC Tones 1, 2, 3 & 4 are Private Mode at 12V FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models MHR and MHW are listed as an audible signal appliance for use with separately listed compatible fire alarm control units. Model APAI5I is listed as an accessory horn for use with separately listed 4-wire conventional duct smoke detectors. (REF: 3240-1653:119) Refer to manufacturer's Installation Manual for details. 03-15-07 jw TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division