Loading...
HomeMy WebLinkAbout2530 CAMPBELL PL; ; AS080138; PermitCity of Carlsbad Sprinkler Permit Permit No: AS080138 Job Address: 2530 CAMPBELL PL Permit Type: SPRINK Parcel No: 2132610600 Lot #: 0 Reference No.: FIL Status: ISSUED Applied 8/26/2008 Approved: 8/28/2008 Issued: 8/28/2008 Inspector: Project Title: BRESSI RANCH -LOT 15 - VIASAT 3 FIRE SPRINKLER INSP. @ $65/EA Applicant: INDUSTRIAL FIRE SPRINKLER CO., 3845 IMPERIAL AV SAN DIEGO CA 619-266-6030 Owner: DANIELSON DSS LLC C/O ST. CROIX CAPITAL CORPORATION 406 9TH AVE #309 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 195 0 195 0 FEB. 17. 29 9:27AM I ND USTRIAL FIRE SPRINKLER 00. k,.,,O833 P. 2/3 Contractor's Material and Test Certificate for Aboveground Piping 11 tb. PROCEDURE i-fr Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name: Bressi Ranch Lot # 15 ViaSat Date 8/28/08 Addres~s'~_ 2530 Campbell Place' Carlsbad-, _C—a----, Accepted by approving authorities (names): CARLSBAD F.D. Address: Plans Installation conforms to accepted plans YES 0 NO Equipment used is approved 0 YES 0 NO If no, explain deviations Has person in charge of fire equipment been instructed as 0 YES 0 NO To location of control valves and care and maintenance Of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? 0 YES 0 NO System components instruction 0 YES 0 NO Care and maintenance instructions 0 YES 0 NO NFPA25 LI YES 0 NO Location of Supplies buildings: system YEAR OF ORIFICE TEMPERATURE MAKE MODEL MANUFACTURER SIZE QUANTITY RATING VIKING VK100 2008 5.6 5 200 VIKING VK302 2008 5.6 216 1550 SPRINKLERS VIKING VK304 2008 5.6 2 200 VIKING VK104 1 2008 1 5.6 1 1 2000 PIPE AND Type of pipe Sched 10/40 FITTINGS Type of fittings Ductile/Cast iron threaded Grooved MAXIMUM TIME TO OPERATE ALARM VALVE ALARM DEVICE THROUGH TEST CONNECTION TYPE MAKE MODEL MINUTES SECONDS OR FLOW INDICATOR VANE VSR-SF 0 45 HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure TEST in excess of 150 psi (10.2 bar) for 2 hours. Differential dry-pipe valve clappers shall be left open during the test to prevent damage. All DESCRIPTION aboveground piping leakage shall be stopped. HYDROSTATIC TEST: ALL PIPING TESTED AT 200 PSI FOR 2 HRS TESTS IF NO EXPLAIN BELL TEST: ALL BELLS TESTED THRU INSPECTORS TEST. IF NO EXPLAIN HYDRAULIC NAMEPLATE PROVIDED: IF NO EXPLAIN: DATA EYES NO REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN FEB. 17. 2U9 12: 1UPM I ND USTRIAL FIRE SPRINKLER CO. IC NO.8336 P. 1 VENF.Guidelnfo - Flexible Sprinkler Hose with Fittings Page 1 of VE N F. Gui del nfo Flexible Sprinkler Hose with Fittings View Listings Page Bottom [Sprinkler System and Water Spray System Devices] Flexible Sprinkler Hose with Fittings See General Information for Sprinkler System and Water Spray System Devices USE AND INSTALLATION This category covers flexible sprinkler hose with fittings intended for use in sprinkler systems between the branch line and sprinkler when installed in accordance with ANSI/NFPA 13, "Standard for the Installation of Sprinkler Systems," ANSI/NFPA 13R, "Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height,' or ANSI/NFPA 13D, 'Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes,' and the manufacturer's installation instructions. As indicated in the individual Listings, these products may have high flexibility or limited flexibility. Products having high flexibility are intended for use in applications where frequent movement between the two ends of the hose is expected after installation. Products having limited flexibility are intended for use in applications where little or no movement between the two ends is expected after installation. A flexible sprinkler hose assembly consists of a flexible hose, inlet fitting for connection to the branch line, and an outlet fitting for connection to the sprinkler. These flexible hose with fittings are intended to be installed using the anchoring devices referenced in the manufacturer's installation instructions. The manufacturer's installation instructions include additional information relative to proper use, such as anchoring device installation, allowable number of bends, minimum bend radii, pressure loss, sprinklers to be attached to the hose, flexibility and maximum temperature rating. These products are intended for use in hydraulically designed sprinkler systems. The hydraulic pressure loss associated with these devices needs to be included in the hydraulic design calculations. Pressure loss is published in equivalent length, in feet of 1-in, diameter Schedule 40 steel pipe (where the Hazen-Williams coefficient of friction is C equals 120). Authorities Having Jurisdiction should be consulted before installation. ADDITIONAL INFORMATION For additional information, see Fire Protection Equipment (MF). REQUIREMENTS The basic standard used to investigate products in this category is UL 2443, "Flexible Sprinkler Hose with Fittings for Fire Protection Service." UL MARK The Listing Mark of Underwriters Laboratories Inc. on the product is the only method provided by UL to identify these products manufactured under its Listing and Follow-Up Service. The Listing Mark for these products includes the UL symbol (as illustrated in the Introduction of this Directory), together with the word "LISTED," a control number, and the product name "Flexible Sprinkler Hose Fitting." Last Updated on 2007-11-09 Questions? Notice of Disclaimer Page Top Copyright © 2008 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the http ://database.ul.comlcgi-bin1XYV/template/LISEXT/ 1 FRAME/showpage.html?&name=VENF.Guidel... 10/01/2008 VENF.EX5269 - Flexible Sprinkler Hose with Fittings Page 1 of VENF.EX5269 Flexible Sprinkler Hose with Fittings Page Bottom Flexible Sprinkler Hose with Fittings See General Information for Flexible Sprinkler Hose with Fittings FLEXHEAD INDUSTRIES INC LOWLAND IND PARK 56 LOWLAND ST HOLLISTON, MA 01746 USA EX5269 Equivalent Length of Max un. Rated Nom Inlet Assembly Max Schedule 40 Pressure, Ambient by Outlet Length, No. of Min Bend Steel Pipe Flexibility Model psig Temp, OF Size, in. ft (mm) 900 Bends Radius, in. i (C = 120), ft Type 2024 175 300 1 by 1/2 2 3 3 11 Limited 2036 175 300 1 by 1/2 3 3 3 16 Limited 2048 175 300 1 by 1/2 4 4 3 24 Limited 2060 175 i 300 1 by 1/2 5 4 3 29 Limited 2072 175 1 300 1 by 1/2 6 4 3 35 1 Limited 2024 175 300 1 by 3/4 2 3 3 12 Limited 2036 175 300 1 by 3/4 3 3 3 18 Limited 2048 175 300 1 by 3/4 4 4 3 23 Limited 2060 175 300 1 by 3/4 5 4 3 29 Limited 2072 175 300 1 by 3/4 6 4 3 32 Limited 2024H 300 300 1 by 1/2 2 3 3 11 1 Limited 2036H 300 300 1 by 1/2 3 3 3 16 Limited 2048H 300 300 1by1/2 44 3 24 Limited 2060H 300 300 1 by 1/2 5 4 3 29 Limited 2072H 300 300 1 by 1/2 6 4 3 35 Limited 2024H 300 300 1 by 3/4 2 3 3 12 1 Limited 2036H 300 300 1 by 3/4 3 4 3 4 3 3 18 23 Limited Limited 2048H [300 300 1 by 3/4 2060H [300 300 1 by 3/4 5 4 3 29 Limited 2072H 300 300 1 by 3/4 6 4 3 32 Limited 2024E 175 [300 1 by 1/2 2 3 3 19 Limited 2036E 175 [300 1 by 1/2 1 3 1 23 Limited 2048E 175 1300 lbyl/2 4 k 3 27 Limited http ://database.ul.comlcgi-binlXY V/template/LISEXT/1 FRAME/showpage.html?name=VENF.EX5269... 10/01/2008 VENF.EX5269 - Flexible Sprinkler Hose with Fittings 2060E 175 1300 j 1 by 1/2 5 2072E 175 1 300 1 1 by 1/2 6 2024E 175 300 1 by 3/4 2 2036E 2048E 175 175 300 300 1 by 3/4 1 b 3/4 3 4 2060E 175 300 1 by 3/4 5 2072E 175 300 1 by 3/4 6 2024HE 300 300 1 by 1/2 2 2036HE 300 300 1 by 1/2 3 2048HE 300 300 [y 1/2 4 2060HE 300 300 1 by 1/2 15 2072HE 300 300 1 by 1/2 6 2024HE 300 300 1 by 3/4 2 2036HE 300 300 1 by 3/4 3 f2048HE 300 300 1by3/4 4 2060HE 300 300 1 by 3/4 5 2072HE 300 300 1'-by-'3/'4 6 Page 2 of 2 3 32 Limited 13 35 Limed 3 18 Limited 3 3 23 Limited 4 3 23 Limited 4 3 29 Limited 4 3 32 Limited 3 i 19 Limited 3 3 23 Limited 3 27 Limited 4 3 32 Limited 4 :3 35 Limited 3 3 18 Limited 3 3 23 Limited 4 3 23 Limited 4 3 129 i Limited k 3 32 Limited These flexible sprinkler hose with fittings are intended to be installed in accordance with the manufacturers installation instructions dated August 20, 2008. Last Upcated on 2008-09-10 Questions? Notice of Disclaimer Page Top Copyright © 2008 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL perm ts the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2008 Underwriters Laboratcries Inc®' An independent organization working for a safer world with integrity, precision and knowledge. http ://database.ul.com/cgi-binIXY V/template/LISEXT/ 1 FRAME/showpage.html?name=VENF.EX5269... 10/01/2008 Scope for UL 2443 Page 1 of 1 Flexible Sprinkler Hose with Fittings for Fire Protection Service UL 2443 I Scope 1.1 This standard covers flexible sprinkler hose with fittings intended for direct connection to fire sprinklers in installations requiring a flexible attachment to the sprinkler system piping such as clean rooms, suspended ceilings, and exhaust ducts. 1.1 revised effective November 10, 2007 1.2 The products covered by this standard are intended for use in sprinkler systems installed in accordance with the Standard for Installation of Sprinkler Systems, NFPA 13; Standard for the Installation of Sprinkler Systems in Residential Occupancies Up to Four Stories in Height, NFPA 13R; and Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Mobile Homes, NFPA 13D. 1.2 revised effective November 10, 2007 UL 2443 references these Standards: 157 * Table of Contents for UL 2443. [ Purchase UL Standards J ( UL Standards InfoNet ) [ UL Standards Catalog ) http://ulstandardsinfonet.ul.com/scopes/scopes.asp?1h2443 .html 10/01/2008 Table of Contents for UL 2443 Page 1 of 1 Q Underwriters UL Standards/n foNet L. Laboratories Table of Contents for UL Standards Table of Contents for UL 2443 [_Scope for UL 2443 Cover Transmittal Table of Contents Body INTRODUCTION I Scope 2 Components 3 Units of Measurement 4 Undated References 5 Glossary CONSTRUCTION 6 General 7 Materials PERFORMANCE 8 Hydrostatic Pressure and Leakage Test 9 Mechanical Strength Test 10 High Temperature Exposure Test 11 Vibration Test 12 Equivalent Length Determination 13 Salt Spray Corrosion Test 14 10-Day Moist Ammonia Air Stress Cracking Test 15 Stress-Corrosion Cracking of Stainless Steel Parts Test 16 Elastomeric Parts Test 17 Low Temperature Test for Dry Pipe Systems 18 Pressure Cycling Test 19 Vacuum Test 20 High Pressure Flow Test 21 Fatigue Test 22 Metallic Coating Thickness Test MANUFACTURING AND PRODUCTION TESTS 23 General MARKINGS 24 General INSTALLATION INSTRUCTIONS 25 General ( Purchase UL Standards----) T --UL InfoNet 1 (UL Standards Catalog J http ://ulstandardsinfonet.ul.comltocs/tocs.asp?doc=s&fh=2443 .toc 10/01/2008 A, A = Total Hose Length including Reducing Fitting and Special Shoulder Nipple -n LN 0 CD MR 9 0 0 NIKJNG4 SupplyNet® FPSJ-4 Technical Features Sizes Available: 38" (965mm) and 58" (1473mm) long. 1" Inlet. 1/2 or 3/4" outlet. Temperature Data : Maximum temperature: 300°F (149°C) Pressure Data: - Maximum Working Pressure: 200 PSI or 13.7 bar (14kgf/cm2) - Test Pressure: 1000 PSI / 70.3 kgf/cm2 (burst) Connections: - Inlet: 1" NPT male thread or DN25 BSP male thread. - Outlet: 1/2" NPT female thread or 3/4" NPT female thread IMPORTANT TECHNICAL NOTES: Minimum bend radius: 3" (76 mm) Maximum number of bends per hose: 3 * Friction Loss Data : UL c UL - Equivalent Length of DN25/1" Steel Pipe (including 3 bends) (VEND - FPSJ 1000 = 34 ft. (10.4 meters) - FPSJ 1500 = 43 ft. (13.1 meters) * UL Listing File Number Ex5290: Paradise Industry Co.Ltd. Flexible Sprinkler Connection — FPSJ-4 Physical Nominal Size Inlet Connection Hose Length A (inch/mm) Outlet Sprinkler Connection Reference Weight (lbs/kg) inch metric 1/2" NPT FPSJ1000-50 2.5/ 1.13 38.0/965 3/4" NPT FPSJ1000-75 2.6/ 1.18 1" NPT 1/2 NPT FPSJ1500-50 2.8/ 1.27 __________ 58.0 / 1473 ____________ 3/4" NPT FPSJ1500-75 2.9/1.32 1" DN25 1/2 NPT FPSJ1000B-50 2.5/ 1.13 38.0/965 ____________ 3/4" NPT FPSJ1000B-75 2.6/ 1.18 1" BSP 1/2 NPT FPSJ1500B-50 2.8/1.27 58.0/1473 3/4" NPT FPSJ1500B-75 2.9/ 1.32 Flexible Sprinkler Connection — FPSJ-4 Materials Item Description Material Specifications 1 Flexible Hose Corrugated Stainless Steel AISI 316L / AISI 304 2 Slip Nut Brass C3771 BC 3 Reducing Fitting (Outlet) Zinc/Steel SPPS 4 Special Shoulder Nipple (Inlet) Zinc/Steel SPPS 5 Reducing Nipple Clamp & Bolt Galvanized Steel SS41 6 Bracket and Clip Assembly #1 Galvanized Steel SS41 7 Sprinkler Support and Cross Bar Assembly Galvanized Steel SS41 8 Bracket and Clip Assembly #2 Galvanized Steel SS41 Worldwide Fire Protection Flexible Sprinkler Connections / FPSJ-4 www.vikingcorp.com Monofortotod for Viking SupptyNet by Paradise Industry Ltd. Refer to Manulorturet't dotetheet. Speehrotiont subject to rhonge e0000t nobre. LN 0 CD Ii 5 NIKJNG4 SupplyNet® FPSJ-4 Installation Instructions Step 1: Insure the proper size hole has been cut into the ceiling tile at specified location. Install the special shoulder nipple into the line tee using the NPT threaded end. Make sure that the arrow and shoulder of the nipple are both pointing toward the direction of the sprinkler. Apply a non-hardening thread compound or Teflon tape to the male threads of the nipple. Make up the nipple with a pipe wrench for a leak-tight connection. Step 2: Install the appropriate frame style sprinkler head to the special reducer fitting on the flexible sprinkler connection. (Note: Flush and Concealed sprinklers cannot be installed before the assembly is installed into the sprinkler support.) Apply a non-hardening thread compound or Teflon tape to the male threads of the sprinkler. Tighten the sprinkler to the special reducer end of the flexible sprinkler reducer with the appropriate sprinkler head wrench. Hand tighten slip nut to reducer. Step 3: Connect the flexible sprinkler connection to the shoulder nipple - check for shoulder and arrow direction. Do not use any joint compound or thread compound on the fine threads of the shoulder nipple. Tighten the slip nut on the flexible connection to the shoulder nipple by hand (see cautions). The nipple and flexible connection are designed to seal in this fashion. Connect the sprinkler connection to the special reducer Cautions - Slip Nut must be tightened by hand. Excessive force can damage the 0-ring. - Repeated bending of one portion of flexible connection before installation may cause breakage or loss of resisting pressure. - Special shoulder nipple is composed of stainless hose and must not fitting by hand. Do not over tighten! Step 4: Attach the bracket and clip assembly, along with the sprinkler support and cross bar to the ceiling grid by hand using wing bolts provided. (Note: Bracket and Clip Assembly #6 is intended for use with pendent and recessed pendent frame style sprinklers. Bracket and Clip Assembly #8 is intended for use with Flush and Concealed style sprinklers.) Do not fully tighten wing bolts on the bracket and clip assembly until the sprinkler support is centered over the hole in the ceiling tile. Step 5: Install the flexible sprinkler connection assembly including the frame style sprinkler into the sprinkler support and adjust the assembly until the proper sprinkler location below the ceiling is obtained. Tighten the wing bolt in the sprinkler support and recheck wing bolts on the bracket and clip assembly for tightness. For Flush and Concealed sprinklers, do not install the sprinkler until after the drop has been inserted into the sprinkler support. Step 6 : Test the system for leaks per the Hydrostatic Test Procedure in the applicable Edition of NFPA 13. Note : This product is designed to be installed in accordance with recognized installation standards, such as NFPA 13 be used as a ground for welding. - When connecting the flexible connection assembly to the sprinkler piping, connect the nipple to the 0-ring first; then connect it to the sprinkler reducer. - For use in heated areas only. Worldwide Fire Protection Flexible Sprinkler Connections / FPSJ-4 www.vikingcorp.com Manufactured for Viking SopplyNet by Paradise Industry Ltd. Refer to Manufacturer's dototheet, Specifications subject to change without node. ASo9o'38 INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name BRESSI RANCH LOT 15 Building : ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System : REMOTE AREAI Contract : 08-619 Data File : calcVl .WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 9/30/08 Hydraulic Design Information Sheet Name - BRESSI RANCH LOT 15 Date - 9/30/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA1 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-3 Construction: C ) Combustible (X) Non-Combustible Ceiling Height - 91 _0 Occupancy - LIGHT S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. C ) 1 ( ) 2 ( ) 3 C ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 1024 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING D Area Per Sprinkler - 171 MAX. ( ) Dry Model MICROFAST E Elevation at Highest Outlet - 91 -0" C ) Deluge Size 1/2" S Hose Allowance - Inside - C ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - C ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 8/24/06 . Cap. - T Time of Test - 9:30AM Rated Cap.- Elev.- E Static Press - 90 8 Press - R Residual Press - 88 Elev. - Well Flow - 1272 Proof Flow S Elevation - 323.0 U P Location - CAMPBELL PLACE P L Source of Information - I.F.S. WITNESSED BY C.M.W.D. Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet C ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet C ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 9/30/08 City Water Supply: Demand: Cl - Static Pressure : 90 Dl - Elevation : 5.630 C2 - Residual Pressure: 88 . D2 - System Flow : 217.054 stem Pressure : 74.045 C2 - Residual Flow : 1272 D2 - SrAdj Hose City _______Hose Demand) : 100 D3 - System Demand : 317.054 Safety Margin : 15.802 150 140 130 p120 R110 100 C2 S90 S 80 u 70 R6° E5° 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 9/30/08 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 15 Date 9/30/08 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. D001 9.0 5.6 13.63 na 20.67 0.1 170 7.0 D002 9.0 5.6 17.75 na 23.59 0.1 85 7.0 D003 9.0 5.6 15.68 na 22.17 0.1 85 7.0 D004 9.0 5.6 14.83 na 21.57 0.1 120 7.0 D005 9.0 5.6 9.32 na 17.1 0.1 171 7.0 D006 9.0 5.6 10.42 na 18.08 0.1 72 7.0 D007 9.0 5.6 15.92 na 22.34 0.1 109 7.0 0008 9.0 5.6 13.09 na 20.26 0.1 109 7.0 0009 9.0 5.6 8.75 na 16.57 0.1 140 7.0 0010 9.0 5.6 10.02 na 17.73 0.1 140 7.0 D01 9.0 5.6 9.19 na 16.98 0.1 140 7.0 88 10.83 11.95 na 20 10.83 13.62 na 19 10.83 19.58 na 18 10.83 20.71 na 17 10.83 23.49 na 16 10.83 12.14 na 14 10.83 13.08 na 15 13.83 13.45 na 13 10.83 17.23 na 12 10.83 21.03 na 8 10.83 17.96 na 28 13.83 18.53 na 9 13.83 19.89 na 10 13.83 21.07 na 11 13.83 24.05 na 1 10.83 11.36 na 27 13.83 11.66 na 2 13.83 12.44 na 3 13.83 14.22 na 4 13.83 17.51 na 5 13.83 21.63 na 6 13.83 29.64 na 7 13.83 30.15 na 72 13.83 39.63 na 64 13.83 40.71 na 65 13.83 42.16 na Ri 13.83 56.55 na BOR 1.0 63.98 na A -4.0 66.18 na BF2 -4.0 66.37 na BF1 -4.0 73.51 na B -4.0 73.61 na 100.0 C -4.0 73.78 na TEST -4.0 74.05 na The maximum velocity is 20.34 and it occurs in the pipe between nodes 5 and 6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn D001 20.67 1.049 1E 2.0 1.000 13.630 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 8 20.67 0.1384 0.0 37.000 5.120 Vel = 7.67 0.0 20.67 17.957 KFactor= 4.88 D002 23.59 1.049 1E 2.0 1.000 17.748 K Factor =5.60 to 120 lEqi 34.0 36.000 -0.793 17 23.59 0.1766 0.0 37.000 6.536 Vel = 8.76 0.0 23.59 23.491 K Factor= 4.87 D003 22.17 1.049 1E 2.0 1.000 15.678 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 18 22.17 0.1575 0.0 37.000 5.828 Vel = 8.23 0.0 22.17 20.713 K Factor = 4.87 D004 21.57 1.049 1E 2.0 1.000 14.833 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 19 21.57 0.1496 0.0 37.000 5.536 Vel = 8.01 0.0 21.57 19.576 K Factor = 4.88 D005 17.10 1.049 1 2.0 1.000 9.324 K Factor =5.60 to 120 lEqi 34.0 36.000 -0.793 16 17.1 0.0974 0.0 37.000 3.604 Vel = 6.35 0.0 17.10 . 12.135 K Factor = 4.91 D006 18.08 1.049 1 2.0 1.000 10.419 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 20 18.08 0.1079 0.0 37.000 3.993 Vel = 6.71 0.0 18.08 13.619 KFactor= 4.90 D007 22.34 1.049 1 2.0 1.000 15.915 K Factor = 5.60 to 120 lEqI 34.0 36.000 -0.793 12 22.34 0.1597 0.0 37.000 5.909 Vel = 8.29 0.0 22.34 21.031 KFactor= 4.87 D008 20.26 1.049 1 2.0 1.000 13.091 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 13 20.26 0.1333 0.0 37.000 4.933 Vel = 7.52 0.0 20.26 17.231 K Factor = 4.88 D009 16.57 1.049 1 2.0 1.000 8.750 K Factor = 5.60 to 120 lEqI 34.0 36.000 -0.793 1 16.57 0.0919 0.0 37.000 3.399 Vel = 6.15 Computer Programs by Hydratec inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.57 11.356 K Factor= 4.92 D010 17.73 1.049 IE 2.0 1.000 10.020 K Factor =5.60 to 120 lEqi 34.0 36.000 -0.793 14 17.73 0.1041 0.0 37.000 3.852 Vet = 6.58 0.0 17.73 . 13.079 K Factor = 4.90 D01 16.98 1.049 1 2.0 1.000 9.191 K Factor = 5.60 to 120 lEqI 34.0 36.000 -0.793 88 16.98 0.0961 0.0 37.000 3.556 Vet = 6.30 0.0 16.98 11.954 K Factor = 4.91 88 16.98 1.049 1E 2.0 3.500 11.954 to 120 1 5.0 7.000 -1.299 27 16.98 0.0960 0.0 10.500 1.008 Vet = 6.30 0.0 16.98 11.663 K Factor = 4.97 20 18.08 1.049 1 2.0 3.500 13.619 to 120 IT 5.0 7.000 -1.299 15 18.08 0.1079 0.0 10.500 1.133 VeI= 6.71 0.0 18.08 13.453 K Factor = 4.93 19 21.57 1.049 1 2.0 3.750 19.576 to 120 1T 5.0 7.000 -1.299 9 21.57 0.1497 0.0 10.750 1.609 Vet = 8.01 0.0 21.57 19.886 K Factor = 4.84 18 22.17 1.049 1E 2.0 3.500 20.713 to 120 1T 5.0 7.000 -1.299 10 22.17 0.1574 0.0 10.500 1.653 Vet = 8.23 0.0 22.17 21.067 K Factor = 4.83 17 23.59 1.049 1 2.0 3.500 23.491 to 120 IT 5.0 7.000 -1.299 11 23.59 0.1766 0.0 10.500 1.854 Vet = 8.76 0.0 23.59 24.046 K Factor = 4.81 16 17.10 1.049 2E 4.0 7.500 12.135 to 120 IT 5.0 9.000 -1.299 2 17.1 0.0974 0.0 16.500 1.607 Vet = 6.35 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. 11cif or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 17.10 12.443 KFactor= 4.85 14 17.73 1.049 2E 4.0 12.080 13.079 to 120 0.0 4.000 -1.299 15 17.73 0.1040 0.0 16.080 1.673 Vel = 6.58 15 18.07 1.380 IT 6.0 1.670 13.453 to 120 0.0 6.000 0.0 3 35.8 0.1005 0.0 7.670 0.771 Vel = 7.68 0.0 35.80 14.224 K Factor = 9.49 13 20.26 1.049 1E 2.0 4.875 17.231 to 120 IT 5.0 7.000 -1.299 4 20.26 0.1332 0.0 11.875 1.582 Vel = 7.52 0.0 20.26 17.514 K Factor = 4.84 12 22.34 1.049 1 2.0 4.875 21.031 to 120 IT 5.0 7.000 -1.299 5 22.34 0.1597 0.0 11.875 1.896 Vel = 8.29 0.0 22.34 21.628 KFactor= 4.80 8 20.67 1.049 3E 6.0 7.500 17.957 to 120 0.0 6.000 -1.299 28 20.67 0.1383 0.0 13.500 1.867 Vel = 7.67 28 0.0 1.049 0.0 9.830 18.525 to 120 0.0 0.0 0.0 9 20.67 0.1385 0.0 9.830 1.361 Vel = 7.67 9 21.57 1.380 0.0 8.660 19.886 to 120 0.0 0.0 0.0 10 42.24 0.1364 0.0 8.660 1.181 Vel= 9.06 10 22.18 1.380 0.0 10.000 21.067 to 120 0.0 0.0 0.0 11 64.42 0.2979 0.0 10.000 2.979 VeI= 13.82 11 23.59 1.380 IT 6.0 5.500 24.046 to 120 0.0 6.000 0.0 7 88.01 0.5307 0.0 11.500 6.103 Vel = 18.88 0.0 88.01 30.149 KFactor= 16.03 1 16.57 1.049 2E 4.0 13.500 11.356 to 120 0.0 4.000 -1.299 27 16.57 0.0918 0.0 17.500 1.606 Vel = 6.15 27 16.97 1.380 IE 3.0 5.750 11.663 to 120 0.0 3.000 0.0 2 33.54 0.0891 0.0 8.750 0.780 Vel = 7.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Fe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 2 17.10 1.380 0.0 9.330 12.443 to 120 0.0 0.0 0.0 3 50.64 0.1909 0.0 9.330 1.781 Vel = 10.86 3 35.80 1.380 0.0 6.410 14.224 to 120 0.0 0.0 0.0 4 86.44 0.5133 0.0 6.410 3.290 Vel = 18.54 4 20.27 1.61 0.0 11.500 17.514 to 120 0.0 0.0 0.0 5 106.71 0.3577 0.0 11.500 4.114 Vel = 16.82 5 22.34 1.61 IT 8.0 7.750 21.628 to 120 0.0 8.000 0.0 6 129.05 0.5085 0.0 15.750 8.009 Vel = 20.34 6 0.0 2.635 0.0 11.080 29.637 to 120 0.0 0.0 0.0 7 129.05 0.0462 0.0 11.080 0.512 Vel= 7.59 7 88.00 2.635 0.0 78.500 30.149 to 120 0.0 0.0 0.0 72 217.05 0.1208 0.0 78.500 9.483 Vel = 12.77 72 0.0 2.635 0.0 8.920 39.632 to 120 0.0 0.0 0.0 64 217.05 0.1209 0.0 8.920 1.078 Vel = 12.77 64 0.0 2.635 0.0 12.000 40.710 to 120 0.0 0.0 0.0 65 217.05 0.1208 0.0 12.000 1.450 Vel = 12.77 65 0.0 2.635 1 8.237 94.420 42.160 to 120 IT 16.474 24.711 0.0 Ri 217.05 0.1208 Q.0 119.131 14.392 Vel= 12.77 RI 0.0 3.26 2E 18.815 15.410 56.552 to 120 IZ 9.408 28.223 5.557 BOR 217.05 0.0428 0.0 43.633 1.869 Vel = 8.34 BOR 0.0 6.16 1E 20.084 5.000 63.978 to 140 0.0 20.084 2.166 A 217.05 0.0014 0.0 25.084 0.036 Vel = 2.34 A 0.0 6.09 2E 43.166 97.000 66.180 to 150 0.0 43.166 0.0 BF2 217.05 0.0014 0.0 140.166 0.190 Vel = 2.39 BF2 0.0 6.16 IT 43.037 16.000 66.370 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 BF1 217.05 0.0015 0.0 99.205 0.144 Vel = 2.34 BF1 0.0 6.09 iG 4.625 22.000 73.514 to 150 iT 46.249 50.874 0.0 B 217.05 0.0013 0.0 72.874 0.098 Vel = 2.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn B 100.00 7.98 2E 54.365 120.000 73.612 Qa = 100 to 150 1G 6.041 113.261 0.0 C 317.05 0.0007 11 52.855 233.261 0.171 Vel = 2.03 C 0.0 9.79 6G 40.485 768.000 73.783 to 150 2T 134.949 205.122 0.0 TEST 317.05 0.0003 1 29.689 973.122 0.262 Vel = 1.35 0.0 317.05 74.045 K Factor= 36.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 15 Building : ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System : REMOTE AREA2 Contract : 08-619 Data File : calcVl.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 9/30/08 Hydraulic Desiqn Information Sheet Name - BRESSI RANCH LOT 15 Date - 9/30/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA2 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-3 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - lO'-O" Occupancy - ORDINARY GROUP 1 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 915 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make VIKING D Area Per Sprinkler - 109 MAX. ( ) Dry Model MICROFAST E Elevation at Highest Outlet - 101_0 ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground Water Flow Test: Date of Test - 8/24/06 Time of Test - 9:30AM Static Press - 90 Residual Press - 88 Flow - 1272 Elevation - 323.0 cation - CAMPBELL PLACE A T E R S U P P L Y Pump Data: Tank or Reservoir: Cap. - Rated Cap.- Elev.- @Press - Elev. - Well Proof Flow Source of Information - I.F.S. WITNESSED BY C.M.W.D. C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 9/30/08 City Water Supply: Demand: Cl -Static Pressure : 90 Dl - Elevation : 6.063 C2 - Residual Pressure: 88 D2 - System Flow : 211.891 sem Pressure : 47.658 C2 - Residual Flow : 1272 D2 - SrA[d Hosej City) Hose Demand) : 250 D3 - System Demand : 461.891 Safety Margin : 42.035 150 - _____ ______ _________ __________ ____________ ______________ _______________ _________________ 140 130 P 120 R110 100 C2 90 S 80 u 70 R6° E5° 40 / 3 30 20 ..... 10 ...... _____ 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 9/30/08 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Flowlhru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 15 Date 9/30/08 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. D101 10.0 5.6 10.55 na 18.19 0.15 96 7.0 D102 10.0 5.6 11.81 na 19.25 0.15 96 7.0 D103 10.0 5.6 8.74 na 16.55 0.15 109 7.0 D104 10.0 5.6 8.87 na 16.68 0.15 96 7.0 D105 10.0 5.6 9.35 na 17.13 0.15 96 7.0 D106 10.0 . 5.6 10.24 na 17.92 0.15 96 7.0 D107 10.0 5.6 11.46 na 18.96 0.15 96 7.0 D108 10.0 5.6 8.52 na 16.35 0.15 109 7.0 D109 10.0 5.6 8.32 na 16.15 0.15 96 7.0 DuO 10.0 5.6 9.09 na 16.88 0.15 96 7.0 Diii 10.0 5.6 11.38 na 18.89 0.15 96 7.0 D112 10.0 5.6 11.44 na 18.94 0.15 96 7.0 26 11.83 15.0 na 75 13.83 15.24 na 29 11.83 11.52 na 128 11.83 12.18 na 21 11.83 13.8 na 30 11.83 10.76 na 127 11.83 11.82 na 22 11.83 . 13.38 na 25 11.83 15.03 na 73 13.83 15.28 na 23 11.83 14.92 na 71 13.83 15.16 na 72 13.83 15.51 na 24 11.83 15.5 na 70 13.83 15.79 na 31 11.83 11.34 na 66 13.83 11.38 na 67 13.83 11.57 na 68 13.83 12.27 na 69 13.83 13.97 na 32 11.83 11.05 na 60 13.83 11.06 na 61 13.83 11.27 na 62 13.83 11.89 na 63 13.83 13.52 na 64 13.83 15.55 na 65 13.83 16.07 na Ri 13.83 29.83 na BOR 1.0 37.18 na A -4.0 39.38 na BF2 -4.0 39.56 na BF1 -4.0 46.7 na B -4.0 46.79 na 250.0 C -4.0 47.13 na TEST -4.0 47.66 na The maximum velocity is 12.47 and it occurs in the pipe between nodes 65 and Ri Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn DIOI 18.19 1.049 1E 2.0 1.000 10.552 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 21 18.19 0.1092 0.0 37.000 4.040 Vel = 6.75 0.0 18.19 13.799 K Factor = 4.90 D102 19.25 1.049 1 2.0 1.000 11.811 K Factor =5.60 to 120 lEqi 34.0 36.000 -0.793 24 19.25 0.1212 0.0 37.000 4.485 Vel = 7.15 0.0 19.25 15.503 K Factor = 4.89 D103 16.55 1.049 IF 2.0 1.000 8.739 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 31 16.55 0.0917 0.0 37.000 3.394 Vel = 6.14 0.0 16.55 11.340 K Factor = 4.91 D104 16.68 1.049 1 2.0 1.000 8.872 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 29 16.68 0.0930 0.0 37.000 3.442 Vel = 6.19 0.0 16.68 11.521 K Factor = 4.91 D105 17.13 1.049 IF 2.0 1.000 9.354 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 128 17.13 0.0977 0.0 37.000 3.615 Vel = 6.36 0.0 17.13 12.176 K Factor = 4.91 D106 17.92 1.049 1E 2.0 1.000 10.244 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 22 17.92 0.1062 0.0 37.000 3.931 Vel = 6.65 0.0 17.92 13.382 K Factor = 4.90 D107 18.96 1.049 IF 2.0 1.000 11.459 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 25 18.96 0.1179 0.0 37.000 4.361 Vel = 7.04 0.0 18.96 15.027 K Factor = 4.89 D108 16.35 1.049 1 2.0 1.000 8.524 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 32 16.35 0.0896 0.0 37.000 3.317 Vel = 6.07 0.0 16.35 11.048 K Factor = 4.92 D109 16.15 1.049 1 2.0 1.000 8.316 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 30 16.15 0.0876 0.0 37.000 3.241 Vel = 6.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "CI' or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.15 10.764 K Factor = 4.92 D1 10 16.88 1.049 1E 2.0 1.000 9.089 K Factor =5.60 to 120 lEqI 34.0 36.000 -0.793 127 16.88 0.0951 0.0 37.000 3.520 Vel = 6.27 0.0 16.88 11.816 K Factor = 4.91 DIll 18.89 1.049 1 2.0 1.000 11.382 K Factor =5.60 to 120 lEqi 34.0 36.000 -0.793 23 18.89 0.1171 0.0 37.000 4.334 Vel= 7.01 0.0 18.89 14.923 K Factor = 4.89 D112 18.94 1.049 1E 2.0 1.000 11.436 K Factor =5.60 to 120 lEqi 34.0 36.000 -0.793 26 18.94 0.1176 0.0 37.000 4.353 VeI= 7.03 0.0 18.94 14.996 K Factor = 4.89 26 18.94 1.049 1E 2.0 2.420 14.996 to 120 IT 5.0 7.000 -0.866 75 18.94 0.1176 0.0 9.420 1.108 VeI= 7.03 75 0.0 1.38 IT 6.0 2.710 15.238 to 120 0.0 6.000 0.0 72 18.94 0.0310 0.0 8.710 0.270 Vel = 4.06 0.0 18.94 15.508 K Factor = 4.81 29 16.68 1.049 1 2.0 2.830 11.521 to 120 iT 5.0 7.000 -0.866 67 16.68 0.0930 0.0 9.830 0.914 Vel = 6.19 0.0 16.68 11.569 K Factor = 4.90 128 17.13 1.049 1 2.0 2.830 12.176 to 120 iT 5.0 7.000 -0.866 68 17.13 0.0977 0.0 9.830 0.960 Vel = 6.36 0.0 17.13 12.270 K Factor = 4.89 21 18.19 1.049 1 2.0 2.500 13.799 to 120 IT 5.0 7.000 -0.866 69 18.19 0.1092 0.0 9.500 1.037 Vel = 6.75 0.0 18.19 13.970 K Factor = 4.87 30 16.15 1.049 1 2.0 3.620 10.764 to 120 2T 10.0 12.000 -0.866 61 16.15 0.0876 0.0 15.620 1.369 Vel = 6.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.15 11.267 KFactor= 4.81 127 16.88 1.049 1E 2.0 2.830 11.816 to 120 iT 5.0 7.000 -0.866 62 16.88 0.0951 0.0 9.830 0.935 Vel = 6.27 0.0 16.88 11.885 K Factor = 4.90 22 17.92 1.049 1 2.0 2.500 13.382 to 120 iT 5.0 7.000 -0.866 63 17.92 0.1062 0.0 9.500 1.009 Vet = 6.65 0.0 17.92 13.525 K Factor = 4.87 25 18.96 1.049 1 2.0 2.500 15.027 to 120 IT 5.0 7.000 -0.866 73 18.96 0.1178 0.0 9.500 1.119 Vel= 7.04 73 0.0 1.38 iT 6.0 2.710 15.280 to 120 0.0 6.000 0.0 64 18.96 0.0310 0.0 8.710 0.270 Vet = 4.07 0.0 18.96 15.550 K Factor = 4.81 23 18.89 1.049 1 2.0 2.420 14.923 to 120 iT 5.0 7.000 -0.866 71 18.89 0.1171 0.0 9.420 1.103 Vel = 7.01 71 0.0 1.38 IT 6.0 5.280 15.160 to 120 0.0 6.000 0.0 72 18.89 0.0309 0.0 11.280 0.348 Vel = 4.05 72 18.94 2.635 0.0 8.910 15.508 to 120 0.0 0.0 0.0 64 37.83 0.0047 0.0 8.910 0.042 Vet = 2.23 0.0 37.83 15.550 K Factor = 9.59 24 19.25 1.049 1E 2.0 2.500 15.503 to 120 iT 5.0 7.000 -0.866 70 19.25 0.1212 0.0 9.500 1.151 VeI= 7.15 70 0.0 1.38 IT 6.0 2.710 15.788 to 120 0.0 6.000 0.0 65 19.25 0.0319 0.0 8.710 0.278 Vel = 4.13 0.0 19.25 16.066 K Factor = 4.80 31 16.55 1.049 1 2.0 2.830 11.340 to 120 IT 5.0 7.000 -0.866 66 16.55 0.0918 0.0 9.830 0.902 Vet = 6.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 66 0.0 1.38 0.0 8.000 11.376 to 120 0.0 0.0 0.0 67 16.55 0.0241 0.0 8.000 0.193 Vel = 3.55 67 16.69 1.38 0.0 8.000 11.569 to 120 0.0 0.0 0.0 68 33.24 0.0876 0.0 8.000 0.701 Vel = 7.13 68 17.12 1.38 0.0 9.000 12.270 to 120 0.0 0.0 0.0 69 50.36 0.1889 0.0 9.000 1.700 Vel = 10.80 69 18.19 1.61 IT 8.0 5.280 13.970 to 120 0.0 8.000 0.0 65 68.55 0.1578 0.0 13.280 2.096 Vel = 10.80 0.0 68.55 16.066 K Factor = 17.10 32 16.35 1.049 1 2.0 2.830 11.048 to 120 1 5.0 7.000 -0.866 60 16.35 0.0896 0.0 9.830 0.881 Vel = 6.07 60 0.0 1.38 0.0 8.630 11.063 to 120 0.0 0.0 0.0 61 16.35 0.0236 0.0 8.630 0.204 Vel = 3.51 61 16.15 1.38 0.0 7.360 11.267 to 120 0.0 0.0 0.0 62 32.5 0.0840 0.0 7.360 0.618 Vel = 6.97 62 16.88 1.38 0.0 9.000 11.885 to 120 0.0 0.0 0.0 63 49.38 0.1822 0.0 9.000 1.640 Vel = 10.59 63 17.92 1.61 IT 8.0 5.280 13.525 to 120 0.0 8.000 0.0 64 67.3 0.1525 0.0 13.280 2.025 Vel = 10.61 64 56.79 2.635 0.0 12.000 15.550 to 120 0.0 0.0 0.0 65 124.09 0.0430 0.0 12.000 0.516 Vel = 7.30 65 87.80 2.635 1E 8.237 94.420 16.066 to 120 iT 16.474 24.711 0.0 Ri 211.89 0.1155 0.0 119.131 13.765 VeI= 12.47 Ri 0.0 3.26 2E 18.815 15.410 29.831 to 120 iZ 9.408 28.223 5.557 BOR 211.89 0.0410 0.0 43.633 1.788 Vel = 8.14 BOR 0.0 6.16 iE 20.084 5.000 37.176 to 140 0.0 20.084 2.166 A 211.89 0.0014 0.0 25.084 0.034 Vel = 2.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn A 0.0 6.09 2E 43.166 97.000 39.376 to 150 0.0 43.166 0.0 BF2 211.89 0.0013 0.0 140.166 0.181 VeI= 2.33 BF2 0.0 6.16 IT 43.037 16.000 39.557 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 BFI 211.89 0.0014 0.0 99.205 0.138 Vel = 2.28 BFI 0.0 6.09 1G 4.625 22.000 46.695 to 150 IT 46.249 50.874 0.0 B 211.89 0.0013 0.0 72.874 0.094 Vel = 2.33 B 250.00 7.98 2E 54.365 120.000 46.789 Qa = 250 to 150 IG 6.041 113.261 0.0 C 461.89 0.0015 IT 52.855 233.261 0.342 Vel = 2.96 C 0.0 9.79 6G 40.485 768.000 47.131 to 150 2T 134.949 205.122 0.0 TEST 461.89 0.0005 1E 29.689 973.122 0.527 Vel = 1.97 0.0 461.89 47.658 K Factor= 66.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name BRESSI RANCH LOT 15 Building ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System REMOTE AREA3 Contract : 08-619 Data File : caIcV2.wxl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 9/30/08 Hydraulic Desiqn Information Sheet Name - BRESSI RANCH LOT 15 Date - 9/30/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA3 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-4 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 10'-0" Occupancy - ORDINARY GROUP 1 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 915 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make VIKING D Area Per Sprinkler - 112 MAX. ( ) Dry Model MICROFAST E Elevation at Highest Outlet - 251 -0" ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 8/24/06 Cap. - T Time of Test - 9:30AM Rated Cap.- Elev.- .E Static Press - 90 8 Press - R Residual Press - 88 Elev. - Well Flow - 1272 Proof Flow S Elevation - 323.0 U P Location - CAMPBELL PLACE P L Source of Information - I.F.S. WITNESSED.BY C.M.W.D. Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 9/30/08 City Water Suppjy: Demand: Cl - Static Pressure : 90 Dl - Elevation : 12.560 C2 - Residual Pressure: 88 D2 - System Flow : 239.199 C2 - Residual Flow : 1272 D2 - System Pressure : 77.753 Hose (Adj City) Hose ( Demand) D3 - System Demand : 489.199 Safety Margin : 11.906 150 140 130 p 12 R110 100 - _____ C2 S90 _______ _________ ___________ _J2 80 u 70 D3 R6° E5° 40 30 20 10 -art- 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 9/30/08 Fitting Legend Abbrev. Name % % 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow ThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 15 Date 9/30/08 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. D001 25.0 5.6 23.28 na 27.02 0.15 96 7.0 D002 25.0 5.6 9.32 na 17.1 0.15 96 7.0 D003 25.0 5.6 9.33 na 17.11 0.15 96 7.0 D004 25.0 5.6 22.14 na 26.35 0.15 96 7.0 D005 25.0 5.6 8.7 na 16.52 0.15 96 7.0 D006 25.0 5.6 8.72 na 16.53 0.15 96 7.0 D007 25.0 5.6 21.44 na 25.93 0.15 96 7.0 D008 25.0 5.6 8.59 na 16.41 0.15 96 7.0 D009 25.0 5.6 8.6 na 16.42 0.15 96 7.0 D010 . 25.0 5.6 21.87 na 26.19 0.15 96 7.0 D01 25.0 5.6 9.0 na 16.8 0.15 112 7.0 D012 25.0 5.6 9.01 na 16.81 0.15 96 7.0 233 30.37 10.76 na 232 30.04 10.89 na SG1 30.04 11.82 na 235 30.37 9.92 na 234 30.04 10.04 na SG2 30.04 10.92 na 237 30.37 9.75 na 236 30.04 9.88 na SG3 30.04 10.9 na 238 30.37 10.32 na 239 30.04 10.45 na SG4 30.04 11.33 na 242 29.75 27.49 na 240 29.75 28.42 na 228 29.75 28.07 na 225 29.75 29.97 na 220 28.5 44.26 na 221 29.71 13.26 na 222 29.71 12.75 na 223 29.71 12.8 na 224 29.71 13.81 na 207 28.5 44.24 na 229 29.42 30.82 na 243 29.42 30.81 na 241 29.42 31.2 na 226 29.42 32.83 na 227 28.5 44.25 na 219 28.5 44.78 na 319 30.0 44.53 na 320 30.0 44.59 na 321 30.0 44.66 na 322 30.0 44.73 na 218 28.5 45.03 na 313 30.17 44.74 na 314 30.17 44.81 na 315 30.17 44.88 na 316 30.17 45.07 na 317 30.17 45.14 na 318 30.17 45.21 na 217 28.5 45.47 na 216 28.5 45.39 na 301 29.83 45.79 na 302 29.83 45.96 na 303 29.83 46.12 na 304 29.83 46.29 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 15 Date 9/30/08 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Ren. 305 29.83 46.45 na 306 29.83 46.62 na 215 28.5 45.2 na 307 30.08 45.08 na 308 30.08 45.18 na 309 30.08 45.27 na 310 30.08 45.37 na 311 30.08 45.46 na 312 30.08 45.56 na 201 28.5 45.49 na 208 28.5 44.26 na 209 28.5 45.47 na 210 28.5 45.47 na 211 28.5 45.48 na 212 28.5 45.75 na 213 28.5 46.56 na 214 28.5 47.06 na 206 28.5 47.72 na 202 28.5 49.74 na 203 28.5 49.75 na 204 28.5 49.78 na 205 28.5 49.92 na TOR 28.5 52.16 na Ri 13.83 59.27 na BOR 1.0 67.06 na A -4.0 69.27 na BF2 -4.0 69.5 na BF1 -4.0 76.67 na B -4.0 76.79 na 250.0 C -4.0 77.17 na TEST -4.0 77.75 na The maximum velocity is 16.35 and it occurs in the pipe between nodes 226 and 211 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn D001 27.02 1.049 IE 2.0 2.500 23.282 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.057 225 27.02 0.2270 0.0 38.500 8.741 Vet = 10.03 0.0 27.02 29.966 K Factor= 4.94 D002 17.10 1.049 IE 2.0 2.500 9.323 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.183 232 17.1 0.0974 0.0 38.500 . 3.749 Vet = 6.35 0.0 17.10 10.889 K Factor = 5.18 D003 17.11 1.049 1E 2.0 2.500 9.333 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.326 233 17.11 0.0975 0.0 38.500 3.754 Vel= 6.35 0.0 17.11 10.761 K Factor = 5.22 D004 26.35 1.049 1E 2.0 2.500 22.138 K Factor =5.60 to 120 lEqi 34.0 36.000 -2.057 240 26.35 0.2167 0.0 38.500 8.343 Vet = 9.78 0.0 26.35 28.424 K Factor = 4.94 D005 16.52 1.049 1E 2.0 2.500 8.705 K Factor =5.60 to 120 lEql 34.0 36.000 -2.183 234 16.52 0.0914 0.0 38.500 3.518 Vet = 6.13 0.0 16.52 10.040 K Factor = 5.21 D006 16.53 1.049 1E 2.0 2.500 8.718 K Factor =5.60 to 120 lEqi 34.0 36.000 -2.326 235 16.53 0.0915 0.0 38.500 3.523 Vet = 6.14 0.0 16.53 9.915 K Factor = 5.25 D007 25.93 1.049 1E 2.0 2.500 21.442 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.057 242 25.93 0.2104 0.0 38.500 8.100 Vet = 9.63 0.0 25.93 27.485 K Factor = 4.95 D008 16.41 1.049 1E 2.0 2.500 8.586 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.183 236 16.41 0.0902 0.0 38.500 3.474 Vet = 6.09 0.0 16.41 9.877 K Factor = 5.22 D009 16.42 1.049 1 2.0 2.500 8.601 K Factor =5.60 to 120 lEqi 34.0 36.000 -2.326 237 16.42 0.0904 0.0 38.500 3.480 Vet = 6.10 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.42 9.755 K Factor = 5.26 D010 26.19 1.049 1E 2.0 2.500 21.874 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.057 228 26.19 0.2143 0.0 38.500 8.251 VeI= 9.72 0.0 26.19 28.068 K Factor = 4.94 D01 16.80 1.049 1 2.0 2.500 9.000 K Factor = 5.60 to 120 lEqI 34.0 36.000 -2.183 239 16.8 0.0943 0.0 38.500 3.629 Vet = 6.24 0.0 16.80 10.446 K Factor = 5.20 D012 16.81 1.049 1 2.0 2.500 9.013 K Factor =5.60 to 120 lEqI 34.0 36.000 -2.326 238 16.81 0.0944 0.0 38.500 3.634 Vet = 6.24 0.0 16.81 10.321 K Factor = 5.23 233 17.11 1.049 IT 5.0 4.420 10.761 to 120 0.0 5.000 0.143 SGI 17.11 0.0975 0.0 9.420 0.918 Vel = 6.35 0.0 17.11 11.822 K Factor = 4.98 232 17.10 1.049 IT 5.0 4.580 10.889 to 120 0.0 5.000 0.0 SGI 17.1 0.0974 0.0 9.580 0.933 Vet = 6.35 SG1 17.11 1.049 1T 5.0 0.250 11.822 to 120 0.0 5.000 0.143 224 34.21 0.3512 0.0 5.250 1.844 Vel = 12.70 0.0 34.21 13.809 KFactor= 9.21 235 16.53 1.049 IT 5.0 4.460 9.915 to 120 0.0 5.000 0.143 SG2 16.53 0.0915 0.0 9.460 0.866 Vet = 6.14 0.0 16.53 10.924 K Factor = 5.00 234 16.52 1.049 IT 5.0 4.670 10.040 to 120 0.0 5.000 0.0 SG2 16.52 0.0914 0.0 9.670 0.884 Vet = 6.13 SG2 16.54 1.049 IT 5.0 0.250 10.924 to 120 0.0 5.000 0.143 223 33.06 0.3297 0.0 5.250 1.731 Vel = 12.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 33.06 12.798 K Factor = 9.24 237 16.42 1.049 iT 5.0 6.080 9.755 to 120 0.0 5.000 0.143 SG3 16.42 0.0903 0.0 11.080 1.001 Vel = 6.10 0.0 16.42 10.899 K Factor = 4.97 236 16.41 1.049 IT 5.0 6.330 9.877 to 120 0.0 5.000 0.0 SG3 16.41 0.0902 0.0 11.330 1.022 Vel = 6.09 SG3 16.42 1.049 iT 5.0 0.250 10.899 to 120 0.0 5.000 0.143 222 32.83 0.3255 0.0 5.250 1.709 Vel = 12.19 0.0 32.83 12.751 KFactor= 9.19 238 16.81 1.049 iT 5.0 4.170 10.321 to 120 0.0 5.000 0.143 SG4 16.81 0.0943 0.0 9.170 0.865 Vet = 6.24 0.0 16.81 11.329 K Factor = 4.99 239 16.80 1.049 IT 5.0 4.370 10.446 to 120 0.0 5.000 0.0 SG4 16.8 0.0942 0.0 9.370 0.883 Vel = 6.24 SG4 16.81 1.049 iT 5.0 0.250 11.329 to 120 0.0 5.000 0.143 221 33.61 0.3400 0.0 5.250 1.785 Vel = 12.48 0.0 33.61 13.257 K Factor = 9.23 242 25.93 1.049 2T 10.0 5.120 27.485 to 120 0.0 10.000 0.143 243 25.93 0.2104 0.0 15.120 3.181 Vel = 9.63 0.0 25.93 30.809 K Factor = 4.67 240 26.35 1.049 2T 10.0 2.170 28.424 to 120 0.0 10.000 0.143 241 26.35 0.2167 0.0 12.170 2.637 Vel= 9.78 0.0 26.35 31.204 K Factor = 4.72 228 26.19 1.049 2T 10.0 2.170 28.068 to 120 0.0 10.000 0.143 229 26.19 0.2143 0.0 12.170 2.608 Vel = 9.72 Computer Programs by Hydratec Ind. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 26.19 30.819 K Factor= 4.72 225 27.02 1.049 2T 10.0 2.000 29.966 to 120 0.0 10.000 0.143 226 27.02 0.2271 0.0 12.000 2.725 Vel = 10.03 0.0 27.02 32.834 K Factor= 4.72 220 -61.48 1.38 3E 9.0 84.520 44.260 to 120 3T 18.0 27.000 -0.524 221 -61.48 -0.2733 0.0 111.520 -30.479 Vel = 13.19 221 33.61 1.38 0.0 8.000 13.257 to 120 0.0 0.0 0.0 222 -27.87 -0.0632 0.0 8.000 -0.506 Vel = 5.98 222 32.83 1.38 0.0 18.000 12.751 to 120 0.0 0.0 0.0 223 4.96 0.0026 0.0 18.000 0.047 Vel = 1.06 223 33.06 1.38 0.0 9.000 12.798 to 120 0.0 0.0 0.0 224 38.02 0.1123 0.0 9.000 1.011 VeI= 8.16 224 34.20 1.38 2T 12.0 73.350 13.809 to 120 0.0 12.000 0.524 212 72.22 0.3681 0.0 85.350 31.419 Vel = 15.49 0.0 72.22 45.752 K Factor= 10.68 207 -29.25 1.38 4E 12.0 164.260 44.237 to 120 2T 12.0 24.000 -0.398 229 -29.25 -0.0692 0.0 188.260 -13.020 Vel = 6.27 229 26.19 1.38 0.0 9.000 30.819 to 120 0.0 0.0 0.0 243 -3.06 -0.0011 0.0 9.000 -0.010 Vel = 0.66 243 25.93 1.38 0.0 9.000 30.809 to 120 0.0 0.0 0.0 241 22187 0.0439 0.0 9.000 0.395 Vel = 4.91 241 26.35 1.38 0.0 9.000 31.204 to 120 0.0 0.0 0.0 226 49.22 0.1811 0.0 9.000 1.630 Vel = 10.56 226 27.02 1.38 2T 12.0 18.090 32.834 to 120 0.0 12.000 0.398 211 76.24 0.4069 0.0 30.090 12.243 VeI= 16.35 0.0 76.24 45.475 K Factor= 11.31 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 10 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 227 7.62 1.38 4T 24.0 187.790 44.254 to 120 0.0 24.000 0.0 210 7.62 0.0057 0.0 211.790 1.215 Vel = 1.63 0.0 7.62 45.469 K Factor = 1.13 219 9.35 1.38 2T 12.0 35.670 44.775 to 120 0.0 12.000 -0.650 319 9.35 .0.0084 0.0 47.670 0.400 Vel = 2.01 319 0.0 1.38 0.0 8.000 44.525 to 120 0.0 0.0 0.0 320 9.35 0.0084 0.0 8.000 0.067 Vel = 2.01 320 0.0 1.38 0.0 8.000 44.592 to 120 0.0 0.0 0.0 321 9.35 0.0084 0.0 8.000 0.067 Vel = 2.01 321 . 0.0 1.38 0.0 8.000 44.659 to 120 0.0 0.0 0.0 322 9.35 0.0084 0.0 8.000 0.067 Vel = 2.01 322 0.0 1.38 21 12.0 129.670 44.726 to 120 0.0 12.000 0.650 213 9.35 0.0084 0.0 141.670 1.188 Vel = 2.01 0.0 9.35 46.564 K Factor = 1.37 218 9.69 1.38 21 12.0 35.830 45.030 to 120 0.0 12.000 -0.723 313 9.69 0.0090 0.0 47.830 0.429 . Vel = 2.08 313 0.0 1.38 0.0 8.000 44.736 to 120 0.0 0.0 0.0 314 9.69 0.0090 0.0 8.000 0.072 Vel = 2.08 314 0.0 1.38 0.0 8.000 44.808 to 120 0.0 0.0 0.0 315 9.69 0.0089 0.0 8.000 0.071 Vel = 2.08 315 0.0 1.38 21 12.0 8.920 44.879 to 120 0.0 12.000 0.0 316 9.69 0.0090 0.0 20.920 0.188 Vel = 2.08 316 0.0 1.38 0.0 8.000 45.067 to 120 0.0 0.0 0.0 317 9.69 0.0089 0.0 8.000 0.071 Vel = 2.08 317 0.0 1.38 0.0 8.000 45.138 to 120 0.0 0.0 0.0 318 9.69 0.0090 0.0 8.000 0.072 Vel = 2.08 318 0.0 1.38 2T 12.0 113.830 45.210 to 120 0.0 12.000 0.723 214 9.69 0.0090 0.0 125.830 1.128 Vel = 2.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 11 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 9.69 47.061 K Factor = 1.41 217 15.03 1.38 4T 24.0 188.450 45.465 to 120 0.0 24.000 0.0 203 15.03 0.0202 0.0 212.450 4.287 Vel = 3.22 0.0 15.03 49.752 K Factor = 2.13 216 15.22 1.38 2T 12.0 35.500 45.386 to 120 0.0 12.000 -0.576 301 15.22 0.0206 0.0 47.500 0.980 Vel = 3.26 301 0.0 1.38 0.0 8.000 45.790 to 120 0.0 0.0 0.0 302 15.22 0.0206 0.0 8.000 0.165 Vel = 3.26 302 0.0 1.38 0.0 8.000 45.955 to 120 0.0 0.0 0.0 303 15.22 0.0206 0.0 8.000 0.165 Vel = 3.26 303 0.0 1.38 0.0 8.000 46.120 to 120 0.0 0.0 0.0 304 15.22 0.0208 0.0 8.000 0.166 Vel = 3.26 304 0.0 1.38 0.0 8.000 46.286 to 120 0.0 0.0 0.0 305 15.22 0.0206 0.0 8.000 0.165 Vel = 3.26 305 0.0 1.38 0.0 8.000 46.451 to 120 0.0 0.0 0.0 306 15.22 0.0206 0.0 8.000 0.165 Vel = 3.26 306 0.0 1.38 2T 12.0 113.500 46.616 to 120 0.0 12.000 0.576 204 15.22 0.0206 0.0 125.500 2.590 Vel = 3.26 0.0 15.22 49.782 K Factor = 2.16 215 11.25 1.38 2T 12.0 35.750 45.204 to 120 0.0 12.000 -0.684 307 11.25 0.0118 0.0 47.750 0.563 VeI= 2.41 307 0.0 1.38 0.0 8.000 45.083 to 120 0.0 0.0 0.0 308 11.25 0.0119 0.0 8.000 0.095 Vel= 2.41 308 0.0 1.38 0.0 8.000 45.178 to 120 0.0 0.0 0.0 309 11.25 0.0118 0.0 8.000 0.094 Vel = 2.41 309 0.0 1.38 0.0 8.000 45.272 to 120 0.0 0.0 0.0 310 11.25 0.0118 0.0 8.000 0.094 Vel = 2.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 12 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 310 0.0 1.38 0.0 8.000 45.366 to 120 0.0 0.0 0.0 311 11.25 0.0119 0.0 8.000 0.095 Vet = 2.41 311 0.0 1.38 0.0 8.000 45.461 to 120 0.0 0.0 0.0 312 11.25 0.0118 0.0 8.000 0.094 Vet = 2.41 312 0.0 1.38 2T 12.0 113.750 45.555 to 120 0.0 12.000 0.684 206 11.25 0.0118 0.0 125.750 1.485. VeI= 2.41 0.0 11.25 47.724 K Factor = 1.63 201 -14.99 2.157 0.0 10.000 45.488 to 120 0.0 0.0 0.0 217 -14.99 -0.0023 0.0 10.000 -0.023 Vel = 1.32 217 -15.03 2.157 0.0 9.660 45.465 to 120 0.0 0.0 0.0 216 -30.02 -0.0082 0.0 9.660 -0.079 Vet = 2.64 216 -15.22 2.157 0.0 10.330 45.386 to 120 0.0 0.0 0.0 215 -45.24 -0.0176 0.0 10.330 -0.182 Vel = 3.97 215 -11.25 2.157 0.0 6.540 45.204 to 120 0.0 0.0 0.0 218 -56.49 -0.0266 0.0 6.540 -0.174 Vel = 4.96 218 -9.69 2.157 0.0 7.180 45.030 to 120 0.0 0.0 0.0 219 -66.18 -0.0355 0.0 7.180 -0.255 Vel = 5.81 219 -9.35 2.157 0.0 11.330 44.775 to 120 0.0 0.0 0.0 220 -75.53 -0.0455 0.0 11.330 -0.515 VeI= 6.63 220 61.48 2.157 0.0 11.340 44.260 to 120 0.0 0.0 0.0 207 -14.05 -0.0020 0.0 11.340 -0.023 Vet = 1.23 207 29.26 2.157 0.0 7.220 44.237 to 120 0.0 0.0 0.0 227 15.21 0.0024 0.0 7.220 0.017 Vel = 1.34 227 -7.62 2.157 0.0 11.160 44.254 to 120 0.0 0.0 0.0 208 7.59 0.0007 0.0 11.160 0.008 Vet = 0.67 208 0.0 1.38 4T 24.0 187.290 44.262 to 120 0.0 24.000 0.0 209 7.59 0.0057 0.0 211.290 1.204 Vet= 1.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 13 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Ca or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 209 0.0 2.635 0.0 11.160 45.466 to 120 0.0 0.0 0.0 210 7.59 0.0003 0.0 11.160 0.003 Vel= 0.45 210 7.62 2.635 0.0 7.220 45.469 to 120 0.0 0.0 0.0 211 15.21 0.0008 0.0 7.220 0.006 Vel= 0.89 211 76.23 2.635 0.0 11.340 45.475 to 120 0.0 0.0 0.0 212 91.44 0.0244 0.0 11.340 0.277 Vel= 5.38 212 72.23 2.635 0.0 11.330 45.752 to 120 0.0 0.0 0.0 213 163.67 0.0717 0.0 11.330 0.812 Vel = 9.63 213 9.35 2.635 0.0 6.260 46.564 to 120 0.0 0.0 0.0 214 173.02 0.0794 0.0 6.260 0.497 Vel = 10.18 214 9.69 2.635 0.0 7.540 47.061 to 120 0.0 0.0 0.0 206 182.71 0.0879 0.0 7.540 0.663 Vel = 10.75 206 11.25 2.635 IT 16.474 5.920 47.724 to 120 0.0 16.474 0.0 205 193.96 0.0981 0.0 22.394 2.197 Vel= 11.41 0.0 193.96 49.921 KFactor= 27.45 201 14.99 1.38 4T 24.0 187.950 45.488 to 120 0.0 24.000 0.0 202 14.99 0.0201 0.0 211.950 4.255 Vel = 3.22 202 0.0 2.635 0.0 10.000 49.743 to 120 0.0 0.0 0.0 203 14.99 0.0009 0.0 10.000 0.009 Vel = 0.88 203 15.03 2.635 0.0 9.660 49.752 to 120 0.0 0.0 0.0 204 30.02 0.0031 0.0 9.660 0.030 Vel = 1.77 204 15.22 2.635 IT 16.474 4.420 49.782 to 120 0.0 16.474 0.0 205 45.24 0.0067 0.0 20.894 0.139 Vel = 2.66 205 193.96 2.635 1 8.237 7.250 49.921 to 120 0.0 8.237 0.0 TOR 239.2 0.1446 0.0 15.487 2.239 Vel = 14.07 TOR 0.0 3.26 0.0 14.670 52.160 to 120 0.0 0.0 6.354 Ri 239.2 0.0513 0.0 14.670 0.752 Vel = 9.19 Ri 0.0 3.26 2E 18.815 15.410 59.266 to 120 1Z 9.408 28.223 5.557 BOR 239.2 0.0513 0.0 43.633 2.237 Vel = 9.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 14 BRESSI RANCH LOT 15 Date 9/30/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn BOR 0.0 6.16 1 20.084 5.000 67.060 to 140 0.0 20.084 2.166 A 239.2 0.0018 0.0 25.084 0.044 Vet = 2.58 A 0.0 6.09 2E 43.166 97.000 69.270 to 150 0.0 43.166 0.0 BF2 239.2 0.0016 0.0 140.166 0.226 Vet = 2.63 BF2 0.0 6.16 iT 43.037 16.000 69.496 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 BFI 239.2 0.0017 0.0 99.205 0.173 Vet = 2.58 BF1 0.0 6.09 1 4.625 22.000 76.669 to 150 iT 46.249 50.874 0.0 B 239.2 0.0016 0.0 72.874 0.118 Vet = 2.63 B 250.00 7.98 2E 54.365 120.000 76.787 Qa = 250 to 150 IG 6.041 113.261 0.0 C 489.2 0.0016 iT 52.855 233.261 0.380 Vet = 3.14 C 0.0 9.79 6G 40.485 768.000 77.167 to 150 2T 134.949 205.122 0.0 TEST 489.2 0.0006 1 29.689 973.122 0.586 Vet = 2.09 0.0 489.20 77.753 K Factor= 55.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I ASOgot sS Industrial Fire Sprinkler Co. Inc. 3845 Imperial Ave. San Diego, Ca. 92113 U U I I I Bressi Ranch Lot 15 Via Sat I 2530 Campbell P1. I Carlsbad Ca. 92009 Hydraulic Calculations Material Sheets I APO5ED AS SUBIRI V TTD CARLBAD ARE DEPARTF1E4T 7-28-08 Drawn By: Mike Gnung Industrial Fire Sprinkler Co. Inc. 619-266-6030 Phone # 619-266-6030 Fax # 619-266-6035 El I I k I 1 I I I I - - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 15 Building : ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System : REMOTE AREA1 Contract : 08-619 Data File : calcVl.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I I I I I I I I I I I INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 7/21/08 Hydraulic Design Information Sheet Name - BRESSI RANCH LOT 15 Date - 7/21/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA1 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-3 Construction: C ) Combustible (X) Non-Combustible Ceiling Height - 91 -0" Occupancy - LIGHT S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date H M Area of Sprinkler Operation - 1024 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING D Area Per Sprinkler - 171 MAX. ( ) Dry Model MICROFAST E Elevation at Highest Outlet - 91 -0" C ) Deluge Size 1/2" S Hose Allowance - Inside - C ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - C ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 8/24/06 Cap. - T Time of Test - 9:30AM Rated Cap.- Elev.- E Static Press - 90 @ Press - R Residual Press - 88 Elev. - Well Flow - 1272 Proof Flow S Elevation - 323.0 U P Location - CAMPBELL PLACE P L Source of Information - I.F.S. WITNESSED BY C.M.W.D. Y C Commodity Class O Storage Ht. Area M Storage Method: Solid Piled % M Single Row C ) Conven. Pallet S R ( ) Double Row C ) Slave Pallet TA ()Mult.Row O C R K Flue Spacing A Longitudinal G E Horizontal Barriers Provided: I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I Location Aisle W. Palletized % Rack C ) Auto. Storage C ) Encap. C ) Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Transverse Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 7/21/08 City Water Sup Y: Demand: Cl -Static Pressure : 90 Dl - Elevation : 5.630 C2 - Residual Pressure: 88 D2 - System Flow : 218.992 C2 - Residual Flow : 1272 D2 - System Pressure : 73.470 Hose (Adj City) ______ Hose ( Demand) : 100 D3 - System Demand : 318.992 Safety Margin : 16.375 150 140 130 p120 R110 100 C2 S90 S 80 —e u 70 R6° E5° 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 7/21/08 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. BRESSI RANCH LOT 15 Page 4 Date 7/21/08 Node Elevation K-Fact Pt Pn Flow Density Area Press I No. Actual Actual D001 9.0 5.6 13.87 na 20.86 D002 9.0 5.6 18.43 na 24.04 D003 9.0 5.6 16.14 na 22.5 D004 9.0 5.6 15.2 na 21.83 D005 9.0 5.6 9.32 na 17.1 D006 9.0 5.6 10.51 na 18.15 D007 9.0 5.6 16.49 na 22.74 I D008 9.0 5.6 13.41 na 20.51 D009 9.0 5.6 8.7 na 16.52 D010 9.0 5.6 10.07 na 17.77 D01 9.0 5.6 9.18 na 16.97 I 88 10.83 10.79 na 20 10.83 12.43 na 19 10.83 18.24 na 18 10.83 19.39 na I 17 10.83 22.21 na 16 10.83 10.97 na 14 10.83 11.89 na 15 13.83 12.28 na I 13 10.83 16.03 na 12 10.83 19.82 na 8 10.83 16.6 na I 28 9 13.83 13.83 17.2 18.58 na na 10 13.83 19.79 na 11 13.83 22.83 na i10.83 10.2 na I 27 13.83 10.5 na 2 13.83 11.27 na 3 13.83 13.05 na 4 13.83 16.35 na 5 13.83 20.48 na I 6 13.83 28.58 na 7 13.83 29.09 na 72 13.83 38.73 na 64 13.83 39.83 na I 65 13.83 41.3 na Ri 13.83 55.93 na BOR 1.0 63.39 na -4.0 65.59 na I A BF2 -4.0 65.79 na BF1 -4.0 72.93 na B 4.0 73.03 na 100.0 -4.0 73.2 na I C TEST -4.0 73.47 na I The maximum velocity is 20.45 and it occurs in the pipe between nodes 5 and 6 I I 0.1 170 7.0 0.1 85 7.0 0.1 85 7.0 0.1 120 7.0 0.1 171 7.0 0.1 72 7.0 0.1 109 7.0 0.1 109 7.0 0.1 140 7.0 0.1 140 7.0 0.1 140 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv ******* Notes • Point Qt Pf/UL Eqv. Ln. Total Pf Pn D001 20.86 1.049 IE 2.0 1.000 13.875 K Factor =5.60 to 120 lEqt 22.0 24.000 -0.793 8 20.86 0.1407 0.0 25.000 3.517 Vet = 7.74 0.0 20.86 16.599 KFactor= 5.12 D002 24.04 1.049 1 E 2.0 1.000 18.430 K Factor = 5.60 to 120 lEqt 22.0 24.000 -0.793 17 24.04 0.1830 0.0 25.000 4.574 Vel = 8.92 1 0.0 24.04 22.211 K Factor = 5.10 D003 22.50 1.049 1 2.0 1.000 16.136 K Factor =5.60 I to 120 lEqt 22.0 24.000 -0.793 18 22.5 0.1618 0.0 25.000 4.044 Vet = 8.35 0.0 I 22.50 19.387 KFactor= 5.11 D004 21.83 1.049 IE 2.0 1.000 15.201 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 I 19 21.83 0.1531 0.0 25.000 3.827 Vet = 8.10 0.0 21.83 18.235 KFactor= 5.11 D005 17.10 1.049 IE 2.0 1.000 9.324 K Factor= 5.60 to 120 lEqt 22.0 24.000 -0.793 16 17.1 0.0974 0.0 25.000 2.435 Vel = 6.35 I 0.0 17.10 10.966 K Factor = 5.16 D006 18.15 1.049 1 2.0 1.000 10.507 K Factor = 5.60 I to 120 lEqI 22.0 24.000 -0.793 20 18.15 0.1088 0.0 25.000 2.719 Vet = 6.74 0.0 I 18.15 12.433 KFactor= 5.15 D007 22.74 1.049 1 E 2.0 1.000 16.490 K Factor = 5.60 to 120 lEqt 22.0 24.000 -0.793 I 12 22.74 0.1650 0.0 25.000 4.126 Vet = 8.44 0.0 22.74 19.823 K Factor = 5.11 I D008 20.51 1.049 1E 2.0 1.000 13.412 K Factor =5.60 to 120 lEqt 22.0 24.000 -0.793 13 20.51 0.1364 0.0 25.000 3.409 Vet = 7.61 I 0.0 20.51 16.028 KFactor= 5.12 D009 16.52 1.049 1E 2.0 1.000 8.705 K Factor =5.60 I to 120 lEqI 22.0 24.000 -0.793 1 16.52 0.0914 0.0 25.000 2.285 Vel = 6.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.52 10.197 KFactor= 5.17 DOIO 17.77 1.049 IE 2.0 1.000 10.072 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 17.77 0.1046 0.0 25.000 2.615 Vel = 6.60 14 0.0 17.77 11.894 KFactor= 5.15 D01 16.97 1.049 1E 2.0 1.000 9.181 K Factor = 5.60 to 120 lEqI 22.0 24.000 -0.793 88 16.97 0.0960 0.0 25.000 2.400 Vel = 6.30 0.0 16.97 10.788 KFactor= 5.17 88 16.97 1.049 1E 2.0 3.500 10.788 to 120 1 5.0 7.000 -1.299 27 16.97 0.0960 0.0 10.500 1.008 Vel = 6.30 0.0 16.97 10.497 K Factor = 5.24 20 18.15 1.049 1E 2.0 3.500 12.433 to 120 iT 5.0 7.000 -1.299 15 18.15 0.1088 0.0 10.500 1.142 Vel= 6.74 0.0 18.15 12.276 KFactor= 5.18 19 21.83 1.049 1E 2.0 3.750 18.235 to 120 IT 5.0 7.000 -1.299 9 21.83 0.1530 0.0 10.750 1.645 Vel = 8.10 0.0 21.83 18.581 KFactor= 5.06 18 22.50 1.049 1 2.0 3.500 19.387 to 120 iT 5.0 7.000 -1.299 10 22.5 0.1617 0.0 10.500 1.698 Vel = 8.35 0.0 22.50 19.786 K Factor = 5.06 17 24.04 1.049 1 2.0 3.500 22.211 to 120 1 5.0 7.000 -1.299 11 24.04 0.1829 0.0 10.500 1.920 VeI= 8.92 0.0 24.04 22.832 K Factor = 5.03 16 17.10 1.049 2E 4.0 7.500 10.966 to 120 IT 5.0 9.000 -1.299 2 17.1 0.0974 0.0 16.500 1.607 Vel= 6.35 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 17.10 11.274 K Factor = 5.09 14 17.77 1.049 2E 4.0 12.080 11.894 to 120 0.0 4.000 -1.299 15 17.77 0.1045 0.0 16.080 1.681 Vel = 6.60 15 18.15 1.380 1 6.0 1.670 12.276 to 120 0.0 6.000 0.0 3 35.92 0.1012 0.0 7.670 0.776 Vel = 7.70 0.0 35.92 13.052 K Factor = 9.94 13 20.51 1.049 1 2.0 4.875 16.028 to 120 IT 5.0 7.000 -1.299 20.51 0.1363 0.0 11.875 1.618 Vel = 7.61 0.0 20.51 16.347 K Factor = 5.07 12 22.74 1.049 1E 2.0 4.875 19.823 to 120 IT 5.0 7.000 -1.299 5 22.74 0.1651 0.0 11.875 1.960 Vel = 8.44 0.0 22.74 20.484 K Factor = 5.02 8 20.86 1.049 3E 6.0 7.500 16.599 to 120 0.0 6.000 -1.299 28 20.86 0.1406 0.0 13.500 1.898 Vel = 7.74 28 0.0 1.049 0.0 9.830 17.198 to 120 0.0 0.0 0.0 9 20.86 0.1407 0.0 9.830 1.383 Vel = 7.74 9 21.83 1.380 0.0 8.660 18.581 to 120 0.0 0.0 0.0 10 42.69 0.1391 0.0 8.660 1.205 Vel = 9.16 10 22.50 1.380 0.0 10.000 19.786 to 120 0.0 0.0 0.0 II 65.19 0.3046 0.0 10.000 3.046 VeI= 13.98 11 24.04 1.380 iT 6.0 5.500 22.832 to 120 0.0 6.000 0.0 7 89.23 0.5443 0.0 11.500 6.260 Vel= 19.14 0.0 ' 89.23 29.092 K Factor = 16.54 1 16.52 1.049 2E 4.0 13.500 10.197 to 120 0.0 4.000 -1.299 27 16.52 0.0914 0.0 17.500 1.599 Vel = 6.13 27 16.97 1.380 1E 3.0 5.750 10.497 to 120 0.0 3.000 0.0 2 33.49 0.0888 0.0 8.750 0.777 Vel = 7.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 2 17.10 1.380 0.0 9.330 11.274 120 0.0 0.0 0.0 I to 3 50.59 0.1906 0.0 9.330 1.778 Vel = 10.85 3 35.92 1.380 0.0 6.410 13.052 to 120 0.0 0.0 0.0 4 I 86.51 0.5140 0.0 6.410 3.295 Vel = 18.56 4 20.51 1.61 0.0 11.500 16.347 to 120 0.0 0.0 0.0 1 5 107.02 0.3597 0.0 11.500 4.137 VeI= 16.87 5 22.74 1.61 IT 8.0 7.750 20.484 to 120 0.0 8.000 0.0 6 129.76 0.5137 0.0 15.750 8.091 Vel = 20.45 6 0.0 2.635 0.0 11.080 28.575 to 120 0.0 0.0 0.0 I 7 129.76 0.0467 0.0 11.080 0.517 Vel = 7.63 7 89.23 2.635 0.0 78.500 29.092 to 120 0.0 0.0 0.0 I 72 218.99 0.1228 0.0 78.500 9.641 Vel = 12.88 72 0.0 2.635 0.0 8.920 38.733 to 120 0.0 0.0 0.0 I 64 218.99 0.1228 0.0 8.920 1.095 Vel = 12.88 64 0.0 2.635 0.0 12.000 39.828 to 120 0.0 0.0 0.0 I 65 218.99 0.1228 0.0 12.000 1.474 VeI= 12.88 65 0.0 2.635 1E 8.237 94.420 41.302 to 120 1T 16.474 24.711 0.0 RI 218.99 0.1228 0.0 119.131 14.631 Vel = 12.88 I RI 0.0 3.26 2E 18.815 15.410 55.933 to 120 1Z 9.408 28.223 5.557 BOR 218.99 0.0435 0.0 43.633 1.900 Vel = 8.42 I BOR 0.0 6.16 1E 20.084 5.000 63.390 to 140 0.0 20.084 2.166 218.99 0.0015 0.0 25.084 0.037 Vel = 2.36 I A A 0.0 6.09 2E 43.166 97.000 65.593 to 150 0.0 43.166 0.0 BF2 218.99 0.0014 0.0 140.166 0.192 Vel = 2.41 I BF2 0.0 6.16 iT 43.037 16.000 65.785 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 BFI 218.99 0.0015 0.0 99.205 0.147 Vel = 2.36 I BFI 0.0 6.09 1G 4.625 22.000 72.932 to 150 iT 46.249 50.874 0.0 B 218.99 0.0014 0.0 72.874 0.100 Vel = 2.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn I B 100.00 7.98 2E 54.365 120.000 73.032 Qa = 100 150 1G 6.041 113.261 0.0 I to C 318.99 0.0007 iT 52.855 233.261 0.172 Vel = 2.05 C 0.0 9.79 6G 40.485 768.000 73.204 150 2T 134.949 205.122 0.0 I to TEST 318.99 0.0003 1E 29.689 973.122 0.266 Vel = 1.36 0.0 318.99 73.470 K Factor = 37.22 I I I I I I I U I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 15 Building : ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System : REMOTE AREA2 Contract : 08-619 Data File calcVl .wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 7/21/08 Hydraulic DesicTn Information Sheet I Name - BRESSI RANCH LOT 15 Date - 7/21/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA2 I Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-3 Construction: C ) Combustible (X) Non-Combustible Ceiling Height - 101 -0" Occupancy - ORDINARY GROUP 1 I S (X) NFPA 13 C ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C C ) Figure Curve S Other Specific Ruling Made By Date I T E N Area of Sprinkler Operation - 915 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make VIKING Area Per Sprinkler - 109 MAX. ( ) Dry Model MICROFAST I D E Elevation at Highest Outlet - 10'-0" ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - C ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 I N Note I Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground Water Flow Test: Date of Test - 8/24/06 Time of Test - 9.: 3OAM Static Press - 93 Residual Press - 83 Flow - 1272 Elevation - 323.0 Location - CAMPBELL PLACE Source of Information - I.F.S. WITNESSED BY C.M.W.D. W A T E R S U P P L Y Pump Data: Rated Cap.- 8 Press - Elev. - Tank or Reservoir: Cap. - Elev.- Well Proof Flow C Commodity Class Location 0 Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet C ) Auto. Storage ( ) Encap. SR Double Row C ) Slave Pallet C ) Solid Shelf ( ) Non TA Mult. Row ( ) Open Shelf O C R 1< Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Pro I UI Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - _ _ _ _ _ _ Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 7/21/08 City Water Supply: Demand: Cl -Static Pressure : 90 Dl - Elevation : 6.063 C2 - Residual Pressure: 88 D2 - System Flow : 213.17 stem Pssure : 46.782 C2 - Residual Flow : 1272 D2 - Sr,11Deman7 Hose dj City ________ Hose : 250 D3 - System Demand : 463.17 Safety Margin : 42.909 150 140 130 p 12 R110 100 C2 S 90 S 80 u 70 R6° (' E U - 40 30 - 20 . .... 10 - 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - IIIINIIIIIIII_ _ Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 7/21/08 Fitting Legend Abbrev. Name % % 1 11/4 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 1 90 Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 15 Date 7/21/08 Node Elevation K-Fact Pt Pn Flow Density I No, Actual Actual D101 10.0 5.6 10.73 na 18.34 0.15 D102 10.0 5.6 12.1 na 19.48 0.15 D103 10.0 5.6 8.75 na 16.57 0.15 I D104 10.0 5.6 8.9 na 16.7 0.15 D105 10.0 5.6 9.42 na 17.19 0.15 D106 10.0 5.6 10.39 na 18.05 0.15 D107 10.0 5.6 11.72 na 19.17 0.15 I D108 10.0 5.6 8.52 na 16.35 0.15 D109 10.0 5.6 8.3 na 16.13 0.15 DuO 10.0 5.6 9.14 na 16.93 0.15 Dlii 10.0 5.6 11.63 na 19.1 0.15 I D112 10.0 5.6 11.69 na 19.15 0.15 26 11.83 13.9 na 75 13.83 14.17 na 29 11.83 10.44 na I 128 11.83 11.09 na 21 11.83 12.71 na 30 11.83 9.69 na I 127 22 11.83 11.83 10.74 12.29 na na 25 11.83 13.93 na 73 13.83 14.21 na I 23 71 11.83 13.83 13.83 14.09 na na 72 13.83 14.44 na 24 11.83 14.41 na 70 13.83 14.72 na I 31 11.83 10.26 na 66 13.83 10.29 na 67 13.83 10.49 na 68 13.83 11.19 na 69 13.83 12.9 na I 32 11.83 9.97 na 60 13.83 9.99 na 61 13.83 10.19 na 62 13.83 10.81 na I 63 13.83 12.45 na 64 13.83 14.48 na 65 13.83 15.01 na Ri 13.83 28.93 na I BOR 1.0 36.29 na A -4.0 38.49 na BF2 -4.0 38.67 na BF1 -4.0 45.81 na I B -4.0 45.91 na 250.0 C -4.0 46.25 na TEST -4.0 46.78 na I The maximum is 12.54 and it in velocity occurs the pipe between nodes 65 and RI I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Area Press 96 7.0 96 7.0 109 7.0 96 7.0 96 7.0 96 7.0 96 7.0 109 7.0 96 7.0 96 7.0 96 7.0 96 7.0 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn D10I 18.34 1.049 IE 2.0 1.000 10.729 K Factor =5.60 to 21 18.34 120 0.1109 lEqI 22.0 0.0 24.000 25.000 -0.793 2.773 Vel = 6.81 0.0 18.34 12.709 KFactor= 5.14 D102 19.48 1.049 1 2.0 1.000 12.104 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 24 19.48 0.1240 0.0 25.000 3.099 Vel = 7.23 0.0 19.48 14.410 KFactor= 5.13 D103 to 16.57 1.049 120 1 E lEqI 2.0 22.0 1.000 24.000 8.753 -0.793 K Factor = 5.60 31 16.57 0.0919 0.0 25.000 2.297 Vel = 6.15 0.0 16.57 10.257 K Factor = 5.17 D104 16.70 1.049 1 2.0 1.000 8.898 K Factor = 5.60 to 120 lEqI 22.0 24.000 -0.793 29 16.7 0.0933 0.0 25.000 2.332 Vel = 6.20 0.0 16.70 10.437 K Factor = 5.17 D105 17.19 1.049 1 2.0 1.000 9.423 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 128 17.19 0.0984 0.0 25.000 2.459 Vel = 6.38 0.0 17.19 11.089 K Factor = 5.16 D106 18.05 1.049 1E 2.0 1.000 10.394 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 22 18.05 0.1077 0.0 25.000 2.693 Vel = 6.70 0.0 18.05 12.294 K Factor = 5.15 D107 19.17 1.049 1 2.0 1.000 11.717 K Factor =5.60 to 120 lEqi 22.0 24.000 -0.793 25 19.17 0.1203 0.0 25.000 3.008 Vel = 7.12 0.0 19.17 13.932 KFactor= 5.14 D108 16.35 1.049 1 2.0 1.000 8.524 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 32 16.35 0.0897 0.0 25.000 2.242 Vel = 6.07 0.0 16.35 9.973 K Factor = 5.18 D109 16.13 1.049 1E 2.0 1.000 8.298 K Factor = 5.60 to 120 lEqI 22.0 24.000 -0.793 30 16.13 0.0875 0.0 25.000 2.187 Vel = 5.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt i Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn I 0.0 16.13 9.692 K Factor = 5.18 DuO I 16.93 1.049 1E 2.0 1.000 9.138 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 127 16.93 0.0956 0.0 25.000 2.390 Vel = 6.28 1 0.0 16.93 10.735 KFactor= 5.17 I Dill to 19.10 1.049 120 1E lEqI 2.0 22.0 1.000 24.000 11.632 -0.793 K Factor =5.60 23 19.1 0.1195 0.0 25.000 2.988 Vel = 7.09 I 19.10 0.0 13.827 K Factor = 5.14 D112 19.15 1.049 1 2.0 1.000 11.692 K Factor =5.60 to 120 lEqI 22.0 24.000 -0.793 26 19.15 0.1201 0.0 25.000 3.002 Vel= 7.11 0.0 19.15 13.901 K Factor = 5.14 26 19.15 1.049 1 2.0 2.420 13.901 to 120 1 5.0 7.000 -0.866 75 19.15 0.1201 0.0 9.420 1.131 Vel = 7.11 I 75 0.0 1.38 iT 6.0 2.710 14.166 to 120 0.0 6.000 0.0 72 19.15 0.0316 0.0 8.710 0.275 Vel = 4.11 1 0.0 19.15 14.441 KFactor= 5.04 29 16.70 1.049 IE 2.0 2.830 10.437 I to 120 IT 5.0 7.000 -0.866 67 16.7 0.0932 0.0 9.830 0.916 Vel = 6.20 0.0 1 16.70 10.487 KFactor= 5.16 128 17.19 1.049 IE 2.0 2.830 11.089 to 120 iT 5.0 7.000 -0.866 I 68 17.19 0.0984 0.0 9.830 0.967 Vel = 6.38 0.0 17.19 11.190 KFactor= 5.14 21 18.34 1.049 1E 2.0 2.500 12.709 to 120 IT 5.0 7.000 -0.866 69 18.34 0.1108 0.0 9.500 1.053 Vel = 6.81 1 0.0 18.34 12.896 K Factor = 5.11 30 16.13 1.049 1 2.0 3.620 9.692 I to 120 2T 10.0 12.000 -0.866 61 16.13 0.0874 0.0 15.620 1.365 Vel = 5.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.13 10.191 K Factor = 5.05 127 16.93 1.049 1 2.0 2.830 10.735 to 120 IT 5.0 7.000 -0.866 16.93 0.0956 0.0 9.830 0.940 Vel = 6.28 62 0.0 16.93 10.809 K Factor = 5.15 18.05 1.049 1E 2.0 2.500 12.294 22 to 120 IT 5.0 7.000 -0.866 63 18.05 0.1076 0.0 9.500 1.022 Vet = 6.70 0.0 18.05 12.450 K Factor = 5.12 25 19.17 1.049 1E 2.0 2.500 13.932 to 73 19.17 120 0.1203 IT 5.0 0.0 7.000 9.500 -0.866 1.143 VeI= 7.12 73 0.0 1.38 IT 6.0 2.710 14.209 to 64 19.17 120 0.0317 0.0 0.0 6.000 8.710 0.0 0.276 Vet = 4.11 0.0 19.17 14.485 K Factor = 5.04 23 19.10 1.049 IE 2.0 2.420 13.827 to 120 IT 5.0 7.000 -0.866 71 19.1 0.1195 0.0 9.420 1.126 VeI= 7.09 71 0.0 1.38 1T 6.0 5.280 14.087 to 120 0.0 6.000 0.0 72 19.1 0.0314 0.0 11.280 0.354 VeI= 4.10 72 19.15 2.635 0.0 8.910 14.441 to 120 0.0 0.0 0.0 64 38.25 0.0049 0.0 8.910 0.044 Vet = 2.25 0.0 38.25 14.485 K Factor = 10.05 24 to 19.48 1.049 120 1E iT 2.0 5.0 2.500 7.000 14.410 -0.866 70 19.48 0.1240 0.0 9.500 1.178 Vet = 7.23 70 0.0 1.38 IT 6.0 2.710 14.722 to 120 0.0 6.000 0.0 65 19.48 0.0326 0.0 8.710 0.284 Vel = 4.18 0.0 ' 19:48 15.006 KFactor= 5.03 31 16.57 1.049 1E 2.0 2.830 10.257 to 120 iT 5.0 7.000 -0.866 66 16.57 0.0919 0.0 9.830 0.903 Vet = 6.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 66 0.0 1.38 0.0 8.000 10.294 to 120 0.0 0.0 0.0 67 16.57 0.0241 0.0 8.000 0.193 Vel = 3.55 67 16.70 1.38 0.0 8.000 10.487 to 120 0.0 0.0 0.0 68 33.27 0.0879 0.0 8.000 0.703 Vel = 7.14 68 17.19 1.38 0.0 9.000 11.190 to 120 0.0 0.0 0.0 I 69 50.46 0.1896 0.0 9.000 1.706 Vel = 10.82 69 18.35 1.61 IT 8.0 5.280 12.896 to 120 0.0 8.000 0.0 I 65 68.81 0.1589 0.0 13.280 2.110 Vel= 10.84 0.0 68.81 15.006 KFactor= 17.76 I 32 16.35 1.049 IE 2.0 2.830 9.973 to 120 iT 5.0 7.000 -0.866 60 16.35 0.0896 0.0 9.830 0.881 Vel = 6.07 I 60 0.0 1.38 0.0 8.630 9.988 to 120 0.0 0.0 0.0 61 16.35 0.0235 0.0 8.630 0.203 Vel = 3.51 I 61 16.13 1.38 0.0 7.360 10.191 to 120 0.0 0.0 0.0 62 32.48 0.0840 0.0 7.360 0.618 Vel = 6.97 I 62 16.93 1.38 0.0 9.000 10.809 to 120 0.0 0.0 0.0 63 49.41 0.1823 0.0 9.000 1.641 Vel = 10.60 I 63 18.05 1.61 iT 8.0 5.280 12.450 to 120 0.0 8.000 0.0 64 67.46 0.1532 0.0 13.280 2.035 Vel = 10.63 I 64 57.42 2.635 0.0 12.000 14.485 to 120 0.0 0.0 0.0 65 124.88 0.0434 0.0 12.000 0.521 Vel = 7.35 I 65 88.29 2.635 1E 8.237 94.420 15.006 to 120 IT 16.474 24.711 0.0 Ri 213.17 0.1168 0.0 119.131 13.919 VeI= 12.54 0.0 3.26 2E 18.815 15.410 28.925 I Ri to 120 IZ 9.408 28.223 5.557 BOR 213.17 0.0414 0.0 43.633 1.808 Vel = 8.19 BOR 0.0 6.16 1E 20.084 5.000 36.290 I to 140 0.0 20.084 2.166 A 213.17 0.0014 0.0 25.084 0.035 Vel = 2.29 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn A 0.0 6.09 2E 43.166 97.000 38.491 to 150 0.0 43.166 0.0 I BF2 213.17 0.0013 0.0 140.166 0.183 Vel = 2.35 BF2 0.0 6.16 IT 43.037 16.000 38.674 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 I BF1 213.17 0.0014 0.0 99.205 0.140 Vel = 2.29 BF1 0.0 6.09 1G 4.625 22.000 45.814 to 150 iT 46.249 50.874 0.0 I B 213.17 0.0013 0.0 72.874 0.095 Vel = 2.35 B 250.00 7.98 2E 54.365 120.000 45.909 Qa = 250 to 150 1 6.041 113.261 0.0 463.17 0.0015 iT 52.855 233.261 0.343 Vel = 2.97 I C C 0.0 9.79 6G 40.485 768.000 46.252 to 150 21 134.949 205.122 0.0 TEST 463.17 0.0005 1 29.689 973.122 0.530 Vel = 1.97 I 0.0 463.17 46.782 KFactor= 67.72 I I I I I I I I I Ccmputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name BRESSI RANCH LOT 15 Building : ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System : REMOTE AREA3 Contract : 08-619 Data File. : caIcV2.wxl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 7/21/08 Hydraulic Design Information Sheet Name - BRESSI RANCH LOT 15 Date - 7/21/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA3 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-4 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - lo'-O" Occupancy - ORDINARY GROUP 1 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 C ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 915 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make VIKING D Area Per Sprinkler - 112 MAX. ( ) Dry Model MICROFAST S Elevation at Highest Outlet - 251 -0" C ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - C ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 N Note I Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground W A T E R S U P P L Y Water Flow Test: Date of Test - 8/24/06 Time of Test - 9:30AM Static Press - 90 Residual Press - 88 Flow - 1272 Elevation - 323.0 Location - CAMPBELL PLACE Source of Information - I.F.S. WITNESSED BY C.M.W.D. Pump Data: Rated Cap.- @ Press - Elev. - Tank or Reservoir: Cap. - Elev.- Well Proof Flow C Commodity Class O Storage Ht. Area M Storage Method: Solid Piled % N Single Row ( ) Conven. Pallet S R ( ) Double Row ( ) Slave Pallet T A Mult. Row O C R K Flue Spacing A Longitudinal G E Horizontal Barriers Provided: Location Aisle W. Palletized % Rack Auto. Storage C ) Encap. Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Transverse Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 7/21/08 City Water Sup Y: Demand: Cl -Static Pressure : 90 Dl - Elevation : 12.560 C2 - Residual Pressure: 88 D2 - System Flow : 240.932 C2 - Residual Flow : 1272 D2 - System Pressure : 76.745 Hose (Adj City) ______ Hose ( Demand) : 250 D3 - System Demand : 490.932 Safe tyMargin : 12.911 150 140 130 p120 R110 100 C2 S 90 —42 5 , o 03 R6° E5° 40 30 20 10 -Dl- 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N "1 .85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 7/21/08 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow ThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 7 Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 15 Date 7/21/08 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Ro D001 25.0 5.6 24.16 na D002 25.0 5.6 9.35 na D003 25.0 5.6 9.36 na D004 25.0 5.6 22.89 na D005 25.0 5.6 8.68 na D006 25.0 5.6 8.7 na D007 25.0 5.6 22.12 na D008 25.0 5.6 8.56 na D009 25.0 5.6 8.57 na D010 25.0 5.6 22.6 na D011 25.0 5.6 9.0 na D012 25.0 5.6 9.01 na 233 30.37 9.62 na 232 30.04 9.75 na SG1 30.04 10.68 na 235 30.37 8.79 na 234 30.04 8.92 na SG2 30.04 9.8 na 237 30.37 8.63 na 236 30.04 8.76 na SG3 30.04 9.77 na 238 30.37 9.19 na 239 30.04 9.31 na SG4 30.04 10.2 na 242 29.75 25.8 na 240 29.75 26.76 na 228 29.75 26.39 na 225 29.75 28.33 na 220 28.5 43.1 na 221 29.71 12.13 na 222 29.71 11.62 na 223 29.71 11.67 na 224 29.71 12.68 na 207 28.5 43.08 na 229 29.42 29.23 na 243 29.42 29.22 na 241 29.42 29.62 na 226 29.42 31.3 na 227 28.5 43.09 na 219 28.5 43.62 na 319 30.0 43.37 na 320 30.0 43.44 na 321 30.0 43.51 na 322 30.0 43.58 na 218 28.5 43.88 na 313 30.17 43.59 na 314 30.17 43.66 na 315 30.17 43.73 na 316 30.17 43.92 na 317 30.17 43.99 na 318 30.17 44.07 na 217 28.5 44.32 na 216 28.5 44.24 na 301 29.83 44.65 na 302 29.83 44.82 na 303 29.83 44.99 na 304 29.83 45.16 na 27.53 0.15 96 7.0 17.12 0.15 96 7.0 17.13 0.15 96 7.0 26.79 0.15 96 7.0 16.5 0.15 96 7.0 16.51 0.15 96 7.0 26.34 0.15 96 7.0 16.38 0.15 96 7.0 16.4 0.15 96 7.0 26.62 0.15 96 7.0 16.8 0.15 112 7.0 16.81 0.15 96 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 15 Date 7/21/08 Node Elevation K-Fact Pt Pn Flow Density Area Press I No. Actual Actual Req. 305 29.83 45.32 na 306 29.83 45.49 na I 215 28.5 44.05 na 307 30.08 43.94 na 308 30.08 44.04 na 309 30.08 44.13 na 310 30.08 44.23 na I 311 30.08 44.32 na 312 30.08 44.42 na 201 28.5 44.34 na 208 28.5 43.1 na I 209 28.5 44.31 na 210 28.5 44.31 na 211 28.5 44.32 na 212 28.5 44.6 na I 213 28.5 45.43 na 214 28.5 45.93 na 206 28.5 46.6 na 202 28.5 48.65 na I 203 28.5 48.66 na 204 28.5 48.69 na 205 28.5 48.83 na TOR 28.5 51.1 na I RI 13.83 58.21 na BOR 1.0 66.04 na A -4.0 68.25 na BF2 -4.0 68.48 na I BF1 -4.0 75.65 na B -4.0 75.77 na 250.0 C -4.0 76.16 na TEST -4.0 76.74 na I The maximum velocity is 16.63 and it occurs in the pipe between nodes 226 and 211 I I I 1 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn DOOI 27.53 1.049 1E 2.0 2.500 24.164 K Factor =5.60 to 120 lEqi 22.0 24.000 -2.057 I 225 27.53 0.2350 0.0 26.500 6.227 Vet = 10.22 0.0 27.53 28.334 K Factor = 5.17 I D002 17.12 1.049 1 2.0 2.500 9.346 K Factor = 5.60 to 120 lEqi 22.0 24.000 -2.183 232 17.12 0.0976 0.0 26.500 2.586 Vet = 6.36 I 0.0 17.12 9.749 K Factor = 5.48 D003 17.13 1.049 1 2.0 2.500 9.357 K Factor =5.60 I to 120 lEqI 22.0 24.000 -2.326 233 17.13 0.0977 0.0 26.500 2.590 Vet = 6.36 0.0 I 17.13 9.621 KFactor= 5.52 D004 26.79 1.049 1 2.0 2.500 22.891 K Factor =5.60 to 120 lEqi 22.0 24.000 -2.057 I 240 26.79 0.2235 0.0 26.500 5.923 Vet = 9.95 0.0 26.79 26.757 K Factor= 5.18 I D005 16.50 1.049 1E 2.0 2.500 8.683 K Factor= 5.60 to 120 lEqi 22.0 24.000 -2.183 234 16.5 0.0912 0.0 26.500 2.416 Vet = 6.13 I 0.0 16.50 8.916 K Factor = 5.53 D006 16.51 1.049 1 E 2.0 2.500 8.697 K Factor = 5.60 I to 120 lEqI 22.0 24.000 -2.326 235 16.51 0.0913 0.0 26.500 2.420 Vet = 6.13 0.0 I 16.51 8.791 KFactor= 5.57 D007 26.34 1.049 1E 2.0 2.500 22.118 K Factor =5.60 to 120 lEqi 22.0 24.000 -2.057 I 242 26.34 0.2165 0.0 26.500 5.738 Vet = 9.78 0.0 26.34 25.799 K Factor = 5.19 I D008 16.38 1.049 1 2.0 2.500 8.555 K Factor =5.60 to 120 lEqI 22.0 24.000 -2.183 236 16.38 0.0900 0.0 26.500 2.384 Vet = 6.08 I 0.0 16.38 8.756 K Factor = 5.54 D009 16.40 1.049 1 2.0 2.500 8.572 K Factor =5.60 I to 120 lEqi 22.0 24.000 -2.326 237 16.4 0.0901 0.0 26.500 2.388 Vel = 6.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 16.40 8.634 K Factor = 5.58 D010 26.62 1.049 1E 2.0 2.500 22.598 K Factor =5.60 to 120 lEqI 22.0 24.000 -2.057 26.62 0.2209 0.0 26.500 5.853 Vel = 9.88 228 0.0 26.62 26.394 K Factor = 5.18 D01116.80 1.049 1 E 2.0 2.500 9.000 K Factor = 5.60 to 120 lEqI 22.0 24.000 -2.183 239 16.8 0.0943 0.0 26.500 2.498 Vel = 6.24 0.0 16.80 9.315 KFactor= 5.50 D012 16.81 1.049 1 2.0 2.500 9.014 K Factor =5.60 to 120 lEqI 22.0 24.000 -2.326 238 16.81 0.0944 0.0 26.500 2.502 Vet = 6.24 0.0 ' 16.81 9.190 K Factor = 5.55 233 17.13 1.049 1 5.0 4.420 9.621 to 120 0.0 5.000 0.143 SGI 17.13 0.0977 0.0 9.420 0.920 Vet = 6.36 0.0 17.13 10.684 K Factor = 5.24 232 17.12 1.049 IT 5.0 4.580 9.749 to 120 0.0 5.000 0.0 SG1 17.12 0.0976 0.0 9.580 0.935 Vet = 6.36 SGI 17.13 1.049 IT 5.0 0.250 10.684 to 120 0.0 5.000 0.143 224 34.25 0.3520 0.0 5.250 1.848 Vet = 12.71 0.0 34.25 12.675 KFactor= 9.62 235 16.51 1.049 IT 5.0 4.460 8.791 to 120 0.0 5.000 0.143 SG2 16.51 0.0913 0.0 9.460 0.864 Vel = 6.13 0.0 16.51 9.798 K Factor = 5.27 234 16.50 1.049 1T 5.0 4.670 8.916 to 120 0.0 5.000 0.0 SG2 16.5 0.0912 0.0 9.670 0.882 Vet = 6.13 SG2 16.52 1.049 1T 5.0 0.250 9.798 to 120 0.0 5.000 0.143 223 I 33.02 0.3290 0.0 5.250 1.727 Vet = 12.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total P1 Pn 0.0 33.02 11.668 K Factor = 9.67 237 16.40 1.049 IT 5.0 6.080 8.634 to 120 0.0 5.000 0.143 SG3 16.4 0.0901 0.0 11.080 0.998 VeI= 6.09 0.0 16.40 9.775 K Factor= 5.25 236 16.38 1.049 IT 5.0 6.330 8.756 to 120 0.0 5.000 0.0 SG3 16.38 0.0899 0.0 11.330 1.019 Vel = 6.08 SG3 16.40 1.049 1 5.0 0.250 9.775 to 120 0.0 5.000 0.143 222 32.78 0.3244 0.0 5.250 1.703 Vel = 12.17 0.0 32.78 11.621 K Factor = 9.62 238 16.81 1.049 IT 5.0 4.170 9.190 to 120 0.0 5.000 0.143 SG4 16.81 0.0943 0.0 9.170 0.865 Vel = 6.24 0.0 16.81 10.198 KFactor= 5.26 239 16.80 1.049 IT 5.0 4.370 9.315 to 120 0.0 5.000 0.0 SG4 16.8 0.0942 0.0 9.370 0.883 Vel = 6.24 SG4 16.81 1.049 IT 5.0 0.250 10.198 to 120 0.0 5.000 0.143 221 33.61 0.3400 0.0 5.250 1.785 Vel = 12.48 0.0 33.61 12.126 K Factor = 9.65 242 26.34 1.049 2T 10.0 5.120 25.799 to 120 0.0 10.000 0.143 243 26.34 0.2165 0.0 15.120 3.273 Vel = 9.78 0.0 26.34 29.215 K Factor = 4.87 240 26.79 1.049 2T 10.0 2.170 26.757 to 120 0.0 10.000 0.143 241 26.79 0.2235 0.0 12.170 2.720 Vel = 9.95 0.0 26.79 29.620 K Factor = 4.92 228 26.62 1.049 2T 10.0 2.170 26.394 to 120 0.0 10.000 0.143 229 I 26.62 0.2210 0.0 12.170 2.689 Vel = 9.88 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 0.0 26.62 29.226 K Factor = 4.92 I 225 27.53 1.049 2T 10.0 2.000 28.334 to 120 0.0 10.000 0.143 226 27.53 0.2350 0.0 12.000 2.820 VeI = 10.22 I 0.0 27.53 31.297 K Factor = 4.92 220 -61.45 1.38 3E 9.0 84.520 43.100 to I 120 31 18.0 27.000 -0.524 221 -61.45 -0.2730 0.0 111.520 -30.450 Vel= 13.18 221 33.61 1.38 0.0 8.000 12.126 to I 120 0.0 0.0 0.0 222 -27.84 -0.0631 0.0 8.000 -0.505 Vel = 5.97 222 32.78 1.38 0.0 18.000 11.621 to I 120 0.0 0.0 0.0 223 4.94 0.0026 0.0 18.000 0.047 VeI= 1.06 223 33.01 1.38 0.0 9.000 11.668 to 120 0.0 0.0 0.0 224 37.95 0.1119 0.0 9.000 1.007 VeI= 8.14 224 34.25 1.38 21 12.0 73.350 12.675 I to 120 0.0 12.000 0.524 212 72.2 0.3679 0.0 85.350 31.403 VeI = 15.49 0.0 1 72.20 44.602 KFactor= 10.81 207 -29.77 1.38 4E 12.0 164.260 43.075 to 120 21 12.0 24.000 -0.398 229 -29.77 -0.0714 0.0 188.260 -13.451 VeI = 6.39 229 26.62 1.38 0.0 9.000 29.226 to 120 0.0 0.0 0.0 I 243 -3.15 -0.0012 0.0 9.000 -0.011 VeI = 0.68 243 26.34 1.38 0.0 9.000 29.215 to 120 0.0 0.0 0.0 I 241 23.19 0.0450 0.0 9.000 0.405 VeI = 4.97 241 26.79 1.38 0.0 9.000 29.620 to 120 0.0 0.0 0.0 I 226 49.98 0.1863 0.0 9.000 1.677 Vet = 10.72 226 27.53 1.38 2T 12.0 18.090 31.297 to 120 0.0 12.000 0.398 I 211 77.51 0.4195 0.0 30.090 12.623 VeI = 16.63 0.0 'I 77.51 44.318 KFactor= 11.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 10 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. NC" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 227 7.63 1.38 4T 24.0 187.790 43.092 to 120 0.0 24.000 0.0 210 7.63 0.0058 0.0 211.790 1.219 Vel = 1.64 0.0 7.63 44.311 K Factor = 1.15 219 I 9.40 1.38 2T 12.0 35.670 43.620 to 120 0.0 12.000 -0.650 319 9.4 0.0085 0.0 47.670 0.404 Vel = 2.02 319 0.0 1.38 0.0 8.000 43.374 to 120 0.0 0.0 0.0 320 9.4 0.0085 0.0 8.000 0.068 Vel = 2.02 320 0.0 1.38 0.0 8.000 43.442 to 120 0.0 0.0 0.0 321 9.4 0.0084 0.0 8.000 0.067 Vel = 2.02 I 321 0.0 1.38 0.0 8.000 43.509 to 120 0.0 0.0 0.0 322 9.4 0.0085 0.0 8.000 0.068 Vel = 2.02 I 322 0.0 1.38 2T 12.0 129.670 43.577 to 120 0.0 12.000 0.650 213 9.4 0.0085 0.0 141.670 1.198 Vel = 2.02 I 0.0 9.40 45.425 K Factor= 1.39 218 9.75 1.38 2T 12.0 35.830 43.879 ' to 120 0.0 12.000 -0.723 313 9.75 0.0090 0.0 47.830 0.432 Vel = 2.09 313 0.0 1.38 0.0 8.000 43.588 I to 120 0.0 0.0 0.0 314 9.75 0.0091 0.0 8.000 0.073 Vel = 2.09 314 0.0 1.38 0.0 8.000 43.661 I to 120 0.0 0.0 0.0 315 9.75 0.0090 0.0 8.000 0.072 Vel = 2.09 315 0.0 1.38 2T 12.0 8.920 43.733 I to 120 0.0 12.000 0.0 316 9.75 0.0090 0.0 20.920 0.189 Vel = 2.09 316 0.0 1.38 0.0 8.000 43.922 120 0.0 0.0 0.0 I to 317 9.75 0.0091 0.0 8.000 0.073 Vel = 2.09 317 0.0 1.38 0.0 8.000 43.995 120 0.0 0.0 0.0 I to 318 9.75 0.0090 0.0 8.000 0.072 Vel = 2.09 318 0.0 1.38 2T 12.0 113.830 44.067 to 120 0.0 12.000 0.723 I 214 9.75 0.0091 0.0 125.830 1.140 Vel= 2.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 11 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes • Point Qt Pf/UL Eqv. Ln. Total Pf Pn I 0.0 9.75 45.930 K Factor = 1.44 I 217 15.13 1.38 4T 24.0 188.450 44.319 to 120 0.0 24.000 0.0 203 15.13 0.0204 0.0 212.450 4.339 Vel = 3.25 I 0.0 15.13 48.658 K Factor= 2.17 15.32 1.38 2T 12.0 35.500 44.238 I 216 to 120 0.0 12.000 -0.576 301 15.32 0.0209 0.0 47.500 0.993 Vel = 3.29 I 301 to 0.0 1.38 120 0.0 0.0 8.000 0.0 44.655 0.0 302 15.32 0.0209 0.0 8.000 0.167 Vel = 3.29 I 302 to 0.0 1.38 120 0.0 0.0 8.000 0.0 44.822 0.0 303 15.32 0.0209 0.0 8.000 0.167 Vel = 3.29 I to 303 0.0 1.38 120 0.0 0.0 8.000 0.0 44.989 0.0 304 15.32 0.0209 0.0 8.000 0.167 Vel = 3.29 I 304 to 0.0 1.38 120 0.0 0.0 8.000 0.0 45.156 0.0 305 15.32 0.0209 0.0 8.000 0.167 Vel = 3.29 305 0.0 1.38 0.0 8.000 45.323 I to 120 0.0 0.0 0.0 306 15.32 0.0209 0.0 8.000 0.167 Vel = 3.29 306 0.0 1.38 2T 12.0 113.500 45.490 I to 120 0.0 12.000 0.576 204 15.32 0.0209 0.0 125.500 2.622 Vel = 3.29 0.0 I 15.32 48.688 KFactor= 2.20 215 11.31 1.38 2T 12.0 35.750 44.054 to 120 0.0 12.000 -0.684 I 307 11.31 0.0119 0.0 47.750 0.570 VeI= 2.43 307 0.0 1.38 0.0 8.000 43.940 to 120 0.0 0.0 0.0 I 308 11.31 0.0119 0.0 8.000 0.095 Vel = 2.43 308 0.0 1.38 0.0 8.000 44.035 to 120 0.0 0.0 0.0 I 309 11.31 0.0119 0.0 8.000 0.095 Vel = 2.43 309 0.0 1.38 0.0 8.000 44.130 to 120 0.0 0.0 0.0 310 11.31 0.0120 0.0 8.000 0.096 Vel= 2.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 12 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt • Ref. "C" or Ftng's Pe Pv ******* Notes • Point Qt Pf/UL Eqv. Ln. Total Pf Pn 310 0.0 1.38 0.0 8.000 44.226 to 311 11.31 120 0.0119 0.0 0.0 0.0 8.000 0.0 0.095 Vel = 2.43 311 0.0 1.38 0.0 8.000 44.321 to 312 11.31 120 0.0120 0.0 0.0 0.0 8.000 0.0 0.096 Vel = 2.43 312 0.0 1.38 21 12.0 113.750 44.417 to 120 0.0 12.000 0.684 206 11.31 0.0119 0.0 125.750 1.500 Vel = 2.43 0.0 11.31 46.601 K Factor = 1.66 201 -15.09 2.157 0.0 10.000 44.342 to 120 0.0 0.0 0.0 217 -15.09 -0.0023 0.0 10.000 -0.023 Vet = 1.32 217 -15.13 2.157 0.0 9.660 44.319 to 120 0.0 0.0 0.0 216 -30.22 -0.0084 0.0 9.660 -0.081 Vet = 2.65 216 -15.31 2.157 0.0 10.330 44.238 to 120 0.0 0.0 0.0 215 -45.53 -0.0178 0.0 10.330 -0.184 Vet = 4.00 215 -11.32 2.157 0.0 6.540 44.054 to 120 0.0 0.0 0.0 218 -56.85 -0.0268 0.0 6.540 -0.175 Vet = 4.99 218 -9.74 2.157 0.0 7.180 43.879 to 120 0.0 0.0 0.0 219 -66.59 -0.0361 0.0 7.180 -0.259 Vet = 5.85 219 -9.40 2.157 0.0 11.330 43.620 to 120 0.0 0.0 0.0 220 -75.99 -0.0459 0.0 11.330 -0.520 Vet = 6.67 220 61.45 2.157 0.0 11.340 43.100 to 120 0.0 0.0 0.0 207 -14.54 -0.0022 0.0 11.340 -0.025 Vel = 1.28 207 29.77 2.157 0.0 7.220 43.075 to 120 0.0 0.0 0.0 227 15.23 0.0024 0.0 7.220 0.017 Vet = 1.34 227 -7.62 2.157 0.0 11.160 43.092 to 120 0.0 0.0 0.0 208 7.61 0.0007 0.0 11.160 0.008 Vet = 0.67 208 0.0 1.38 41 24.0 187.290 43.100 to 120 0.0 24.000 0.0 209 7.61 0.0057 0.0 211.290 1.208 Vel = 1.63 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 13 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt • Ref. "C" or Ftng's Pe Pv Notes • Point Qt Pf/UL Eqv. Ln. Total Pf Pn 209 0.0 2.635 0.0 11.160 44.308 to 210 7.61 120 0.0003 0.0 0.0 0.0 11.160 0.0 0.003 Vel = 0.45 210 7.62 2.635 0.0 7.220 44.311 to 120 0.0 0.0 0.0 211 15.23 0.0010 0.0 7.220 0.007 Vel = 0.90 211 77.51 2.635 0.0 11.340 44.318 to 120 0.0 0.0 0.0 I 212 92.74 0.0250 0.0 11.340 0.284 Vel = 5.46 212 72.20 2.635 0.0 11.330 44.602 to 120 0.0 0.0 0.0 I 213 164.94 0.0726 0.0 11.330 0.823 Vel = 9.70 213 9.40 2.635 0.0 6.260 45.425 to 120 0.0 0.0 0.0 I 214 174.34 0.0807 0.0 6.260 0.505 Vel = 10.26 214 9.74 2.635 0.0 7.540 45.930 to 120 0.0 0.0 0.0 I 206 184.08 0.0890 0.0 7.540 0.671 Vel = 10.83 206 11.32 2.635 iT 16.474 5.920 46.601 to 120 0.0 16.474 0.0 205 195.4 0.0994 0.0 22.394 2.227 Vel = 11.50 I 0.0 195.40 48.828 K Factor = 27.96 U 201 15.09 1.38 4T 24.0 187.950 44.342 to 120 0.0 24.000 0.0 202 15.09 0.0203 0.0 211.950 4.307 Vel = 3.24 I 202 0.0 2.635 0.0 10.000 48.649 to 120 0.0 0.0 0.0 203 15.09 0.0009 0.0 10.000 0.009 Vel = 0.89 I 203 15.13 2.635 0.0 9.660 48.658 to 120 0.0 0.0 0.0 204 30.22 0.0031 0.0 9.660 0.030 Vel = 1.78 15.31 2.635 1 16.474 4.420 48.688 I 204 to 120 0.0 16.474 0.0 205 45.53 0.0067 0.0 20.894 0.140 Vel = 2.68 195.40 2.635 1E 8.237 7.250 48.828 I 205 to 120 0.0 8.237 0.0 TOR 240.93 0.1466 0.0 15.487 2.270 Vel = 14.17 0.0 3.26 0.0 14.670 51.098 I TOR to 120 0.0 0.0 6.354 RI 240.93 0.0519 0.0 14.670 0.762 Vel = 9.26 0.0 3.26 2E 18.815 15.410 58.214 I RI to 120 1Z 9.408 28.223 5.557 BOR 240.93 0.0520 0.0 43.633 2.267 Vel = 9.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 14 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn BOR 0.0 6.16 1 20.084 5.000 66.038 140 0.0 20.084 2.166 I to A 240.93 0.0018 0.0 25.084 0.044 Vel = 2.59 A 0.0 6.09 2E 43.166 97.000 68.248 150 0.0 43.166 0.0 I to BF2 240.93 0.0016 0.0 140.166 0.230 Vel = 2.65 BF2 0.0 6.16 IT 43.037 16.000 68.478 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 BF1 240.93 0.0018 0.0 99.205 0.175 Vel = 2.59 BF1 0.0 6.09 1 4.625 22.000 75.653 to 150 IT 46.249 50.874 0.0 I B 240.93 0.0016 0.0 72.874 0.119 Vel = 2.65 B 250.00 7.98 2E 54.365 120.000 75.772 Qa = 250 to 150 1G 6.041 113.261 0.0 I C 490.93 0.0016 IT 52.855 233.261 0.383 Vel = 3.15 C 0.0 9.79 6G 40.485 768.000 76.155 to 150 2T 134.949 205.122 0.0 I TEST 490.93 0.0006 1E 29.689 973.122 0.590 Vel = 2.09 0.0 490.93 76.745 K Factor = 56.04 I I I I 1 I I 1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AutoPeaking Summary INDUSTRIAL FIRE SPRINKLER CO. BRESSI RANCH LOT 15 Auto Peaking Summary - List of Pipes for Area Calculated Page 15 Date 7/21/08 I Left Side I From To Length Right Side From To Length I 220 207 221 84.520 224 212 73.350 229 164.260 226 211 18.090 Flow Pressure Pressure Required Required Differential I Left Area Calculated Right I I I 9.000 494.430 76.570 -0.175 490.932 76.745 0.000 9.000 487.740 76.599 -0.146 I Typical Distance Between Heads = 9.000 Split Point Used in Worst Area Peaked = D01 I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AL in F~~W~.q - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 15 Building ViaSat BUILDING 7 Location : 2530 CAMPBELL PLACE System : REMOTE AREA4 Contract : 08-619 Data File : caIcV2.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 15 Date 7/21/08 Hydraulic Desicn Information Sheet Name - BRESSI RANCH LOT 15 Date - 7/21/08 Location - 2530 CAMPBELL PLACE Building - ViaSat BUILDING 7 System No. - REMOTE AREA4 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - 08-619 Calculated By - M.G. Drawing No. - FP-4 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - VARIES Occupancy - LIGHT S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING D Area Per Sprinkler - 130 ( ) Dry Model MICROMATIC H Elevation at Highest Outlet - 301 -6" ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 100 N Note I Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground I I I I I I I I I W A T Water Flow Test: Date of Test - 8/24/06 Time of Test - 9:30AM Static Press - 90 Residual Press - 88 Flow - 1272 Elevation - 323.0 Pump Data: Rated Cap.- @ Press - Elev. - Tank or Reservoir: Cap. - Elev.- Well Proof Flow Location - CAMPBELL PLACE Source of Information - I.F.S. WITNESSED BY C.M.W.D. Commodity Storage Ht. Storage Method: Single Row Double Row Mult. Row Class Area Solid Piled Conven. Pallet Slave Pallet Location Aisle W. Palletized % Rack Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Flue Spacing Clearance:Storage to Ceiling Longitudinal Transverse IL Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 15 Date 7/21/08 City Water Sup!y: Demand: Cl - Static Pressure : 90 Dl - Elevation : 14.799 C2 - Residual Pressure: 88 D2 - System Flow : 347.099 stem Pressure : 67.864 C2 - Residual Flow : 1272 D2 - SrDemaV) HoseAdj Ci __ Hose : 100____ D3 - System Demand : 447.099 Safety Margin : 21.847 150 140 130 P 120 R110 E 100 Cl C2 S90 S80 D2 u70 or R6° _/1i E5° 40 30 20 10 --Di 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 15 Date 7/21/08 Fitting Legend Abbrev. Name % 3/4 1 11/4 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow ThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switr.h 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. BRESSI RANCH LOT 15 Page 4 Date 7/21/08 Node Elevation K-Fact Pt Pn Flow Density Area Press Actual Actual Req. No. SPR1 30.16 5.6 7.0 na 14.82 0.1 130 7.0 SPR2 SPR3 30.41 30.5 5.6 5.6 7.0 7.0 na na 14.82 14.82 0.1 130 7.0 0.1 130 7.0 SPR4 30.33 5.6 7.0 na 14.82 0.1 130 7.0 227 28.5 18.35 na 220 221 28.5 29.71 17.69 23.07 na na 222 29.71 23.5 na 223 29.71 24.45 na 224 29.71 24.93 na 28.5 18.19 na 207 229 29.42 26.69 na 243 29.42 27.11 na 241 29.42 27.54 na ' 226 29.42 27.96 na 219 28.5 16.82 na 319 30.0 K=K@EQ4 12.18 na 18.07 320 30.0 K= K@ EQ4 12.03 na 17.96 321 30.0 K=K@ EQ4 12.04 na 17.97 322 30.0 K= K@ EQ4 12.36 na 18.2 218 28.5 16.56 na 313 30.17 K= K @ EQ3 8.91 na 15.38 314 30.17 K= K@ EQ3 8.39 na 14.93 315 30.17 K=K@ EQ3 8.26 na 14.82 316 30.17 K= K @ EQ3 8.27 na 14.82 317 30.17 K= K @ EQ3 8.46 na 14.99 318 217 30.17 28.5 K=K@ EQ3 9.09 16.87 na na 15.54 216 28.5 16.56 na 301 29.83 K= K @ EQ1 9.22 na 15.79 302 303 29.83 29.83 K= K@ EQ1 K= K@ EQ1 8.73 8.63 na na 15.37 15.27 304 29.83 K= K @ EQ1 8.64 na 15.28 305 29.83 K= K @ EQ1 8.87 na 15.49 29.83 K= K@ EQ1 9.6 na 16.12 306 215 28.5 16.52 na 307 30.08 K= K @ EQ2 8.97 na 15.47 308 30.08 K= K @ EQ2 8.46 na 15.03 309 30.08 K= K @ EQ2 8.34 na 14.92 30.08 K= K@ EQ2 8.34 na 14.92 310 311 30.08 K=K@EQ2 8.54 na 15.1 312 30.08 K=K@EQ2 9.19 na 15.66 201 28.5 16.96 na 28.5 18.42 na 208 209 28.5 29.69 na 210 28.5 29.72 na 211 28.5 29.78 na 212 28.5 29.97 na 213 28.5 30.3 na 214 28.5 30.63 na 206 28.5 31.32 na 202 28.5 33.54 na 203 28.5 33.57 na 204 28.5 33.69 na 205 28.5 34.44 na 28.5 38.9 na TOR Ri 13.83 46.75 na I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard INDUSTRIAL FIRE SPRINKLER CO. BRESSI RANCH LOT 15 ' Node No. Elevation K-Fact Pt Actual Pn Flow Actual BOR 1.0 56.76 na l A BF2 -4.0 -4.0 59.02 59.47 na na BF1 -4.0 66.81 na B -4.0 67.05 na 100.0 C -4.0 67.37 na I TEST -4.0 67.86 na Page 5 Date 7/21/08 Density Area Press The maximum velocity is 20.42 and it occurs in the pipe between nodes 205 and TOR I I I 1 1 I I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn SPRI 14.82 1.049 IT 5.0 0.330 7.000 K Factor =5.60 to 120 0.0 5.000 0.719 I EQI 14.82 0.0747 0.0 5.330 0.398 Vel = 5.50 0.0 14.82 . 8.117 KFactor= 5.20 I SPR2 14.82 1.049 iT 5.0 0.330 7.000 K Factor =5.60 to 120 0.0 5.000 0.827 EQ2 14.82 0.0747 0.0 5.330 0.398 Vel = 5.50 I 0.0 14.82 8.225 KFactor= 5.17 SPR3 14.82 1.049 IT 5.0 0.330 7.000 K Factor =5.60 I to 120 0.0 5.000 0.866 EQ3 14.82 0.0747 0.0 5.330 0.398 Vel = 5.50 0.0 ' 14.82 8.264 K Factor = 5.16 SPR4 14.82 1.049 IT 5.0 0.330 7.000 K Factor =5.60 to 120 0.0 5.000 0.793 I EQ4 14.82 0.0747 0.0 5.330 0.398 Vel = 5.50 0.0 14.82 8.191 K Factor = 5.18 I 227 25.51 1.38 4T 24.0 187.790 18.351 to 120 0.0 24.000 0.0 210 25.51 0.0537 0.0 211.790 11.369 Vel= 5.47 I 0.0 25.51 29.720 K Factor = 4.68 220 25.33 1.38 3E 9.0 84.520 17.688 I to 120 3T 18.0 27.000 -0.524 221 25.33 0.0530 0.0 111.520 5.907 Vel = 5.43 221 0.0 1.38 0.0 8.000 23.071 I to 120 0.0 0.0 0.0 222 25.33 0.0530 0.0 8.000 0.424 Vel = 5.43 222 0.0 1.38 0.0 18.000 23.495 I to 120 0.0 0.0 0.0 223 25.33 0.0530 0.0 18.000 0.954 Vel = 5.43 223 0.0 1.38 0.0 9.000 24.449 120 0.0 0.0 0.0 I to 224 25.33 0.0529 0.0 9.000 0.476 Vel = 5.43 224 0.0 1.38 21 12.0 73.350 24.925 to 120 0.0 12.000 0.524 I 212 25.33 0.0530 0.0 85.350 4.522 Vel = 5.43 0.0 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 25.33 29.971 K Factor= 4.63 I 207 to 23.80 1.38 120 4E 12.0 2T 12.0 164.260 24.000 18.193 -0.398 229 23.8 0.0472 0.0 188.260 8.890 Vel = 5.11 I 229 to 0.0 1.38 120 0.0 0.0 9.000 0.0 26.685 0.0 243 23.8 0.0472 0.0 9.000 0.425 Vel = 5.11 243 0.0 1.38 0.0 9.000 27.110 I to 120 0.0 0.0 0.0 241 23.8 0.0473 0.0 9.000 0.426 Vel = 5.11 241 0.0 1.38 0.0 9.000 27.536 I to 120 0.0 0.0 0.0 226 23.8 0.0471 0.0 9.000 0.424 Vel = 5.11 226 0.0 1.38 2T 12.0 18.090 27.960 I to 120 0.0 12.000 0.398 211 23.8 0.0473 0.0 30.090 1.422 Vel= 5.11 0.0 I 23.80 29.780 K Factor = 4.36 219 -32.43 1.38 2T 12.0 35.670 16.822 to 120 0.0 12.000 -0.650 I 319 -32.43 -0.0837 0.0 47.670 -3.990 Vel = 6.96 319 18.07 1.38 0.0 8.000 12.182 K Factor@ node EQ4 to 120 0.0 0.0 0.0 I 320 -14.36 -0.0186 0.0 8.000 -0.149 Vel = 3.08 320 17.96 1.38 0.0 8.000 12.033 K Factor @ node EQ4 to 120 0.0 0.0 0.0 321 3.6 0.0015 0.0 8.000 0.012 Vel = 0.77 I 321 17.96 1.38 0.0 8.000 12.045 K Factor@ node EQ4 to 120 0.0 0.0 0.0 322 21.56 0.0394 0.0 8.000 0.315 Vel = 4.62 I 322 18.20 1.38 2T 12.0 129.670 12.360 K Factor@ node EQ4 to 120 0.0 12.000 0.650 213 39.76 0.1220 0.0 141.670 17.287 Vel = 8.53 I 0.0 39.76 30.297 K Factor = 7.22 I 218 -43.60 1.38 2T 12.0 35.830 16.556 to 120 0.0 12.000 -0.723 313 -43.6 -0.1447 0.0 47.830 -6.923 Vel = 9.35 I 313 15.38 1.38 0.0 8.000 8.910 K Factor @ node EQ3 to 120 0.0 0.0 0.0 314 -28.22 -0.0646 0.0 8.000 -0.517 Vel = 6.05 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt I Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 314 14.93 1.38 0.0 8.000 8.393 K Factor @ node EQ3 to 120 0.0 0.0 0.0 I 315 -13.29 -0.0161 0.0 8.000 -0.129 Vet = 2.85 315 14.82 1.38 2T 12.0 8.920 8.264 K Factor @ node EQ3 to 120 0.0 12.000 0.0 ' 316 1.53 0.0003 0.0 20.920 0.007 Vet = 0.33 316 14.82 1.38 0.0 8.000 8.271 K Factor @ node EQ3 to 120 0.0 0.0 0.0 I 317 16.35 0.0235 0.0 8.000 0.188 Vel = 3.51 317 14.99 1.38 0.0 8.000 8.459 K Factor@ node EQ3 to 120 0.0 0.0 0.0 I 318 31.34 0.0786 0.0 8.000 0.629 Vel = 6.72 318 15.54 1.38 2T 12.0 113.830 9.088 K Factor@ node EQ3 to 120 0.0 12.000 0.723 214 46.88 0.1655 0.0 125.830 20.822 Vet = 10.06 I 0.0 46.88 30.633 K Factor = 8.47 ' 217 31.35 1.38 41 24.0 188.450 16.868 to 120 0.0 24.000 0.0 203 31.35 0.0786 0.0 212.450 16.703 Vet = 6.72 I 0.0 31.35 33.571 K Factor = 5.41 216 -43.20 1.38 2T 12.0 35.500 16.558 to 120 0.0 12.000 -0.576 I 301 -43.2 -0.1423 0.0 47.500 -6.758 Vet = 9.27 301 15.79 1.38 0.0 8.000 9.224 K Factor @ node EQI to 120 0.0 0.0 0.0 I 302 -27.41 -0.0612 0.0 8.000 -0.490 Vel = 5.88 302 15.37 1.38 0.0 8.000 8.734 K Factor @ node EQI to 120 0.0 0.0 0.0 I 303 -12.04 -0.0134 0.0 8.000 -0.107 Vel = 2.58 303 15.28 1.38 0.0 8.000 8.627 K Factor @ node EQ1 to 120 0.0 0.0 0.0 I 304 3.24 0.0011 0.0 8.000 0.009 Vet = 0.69 304 15.28 1.38 0.0 8.000 8.636 K Factor @ node EQI to 120 0.0 0.0 0.0 I 305 18.52 0.0298 0.0 8.000 0.238 Vet = 3.97 305 15.49 1.38 0.0 8.000 8.874 K Factor @ node EQI 120 0.0 0.0 0.0 I to 306 34.01 0.0914 0.0 8.000 0.731 Vet = 7.30 306 16.12 1.38 2T 12.0 113.500 9.605 K Factor @ node EQl to 120 0.0 12.000 0.576 I 204 50.13 0.1873 0.0 125.500 23.507 Vet = 10.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes I Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 0.0 50.13 33.688 KFactor= 8.64 I 215 -43.45 1.38 21 12.0 35.750 16.520 to 120 0.0 12.000 -0.684 ' 307 -43.45 -0.1438 0.0 47.750 -6.866 Vel = 9.32 307 15.47 1.38 0.0 8.000 8.970 K Factor @ node EQ2 to 120 0.0 0.0 0.0 308 -27.98 -0.0638 0.0 8.000 -0.510 Vel = 6.00 I 308 15.03 1.38 0.0 8.000 8.460 K Factor @ node EQ2 to 120 0.0 0.0 0.0 309 -12.95 -0.0154 0.0 8.000 -0.123 Vel = 2.78 I 309 14.91 1.38 0.0 8.000 8.337 K Factor @ node E02 to 120 0.0 0.0 0.0 310 1.96 0.0005 0.0 8.000 0.004 Vel = 0.42 I 310 14.92 1.38 0.0 8.000 8.341 K Factor @ node EQ2 to 120 0.0 0.0 0.0 311 16.88 0.0250 0.0 8.000 0.200 Vel = 3.62 311 15.10 1.38 0.0 8.000 8.541 K Factor @ node EQ2 to 120 0.0 0.0 0.0 312 31.98 0.0816 0.0 8.000 0.653 Vel = 6.86 312 15.67 1.38 21 12.0 113.750 9.194 K Factor@ node EQ2 to 120 0.0 12.000 0.684 206 47.65 0.1705 0.0 125.750 21.444 Vel = 10.22 1 0.0 47.65 31.322 K Factor = 8.51 201 -31.27 2.157 0.0 10.000 16.957 to 120 0.0 0.0 0.0 217 -31.27 -0.0089 0.0 10.000 -0.089 Vel = 2.75 217 -31.35 2.157 0.0 9.660 16.868 I to 120 0.0 0.0 0.0 216 -62.62 -0.0321 0.0 9.660 -0.310 Vel = 5.50 216 43.20 2.157 0.0 10.330 16.558 I to 120 0.0 0.0 0.0 215 -19.42 -0.0037 0.0 10.330 -0.038 Vel = 1.71 215 43.45 2.157 0.0 6.540 16.520 I to 120 0.0 0.0 0.0 218 24.03 0.0055 0.0 6.540 0.036 Vel = 2.11 218 43.60 2.157 0.0 7.180 16.556 I to 120 0.0 0.0 0.0 219 67.63 0.0370 0.0 7.180 0.266 Vel = 5.94 219 32.44 2.157 0.0 11.330 16.822 I to 120 0.0 0.0 0.0 220 100.07 0.0764 0.0 11.330 0.866 Vel = 8.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 10 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 220 -25.33 2.157 0.0 11.340 17.688 I to 207 74.74 120 0.0445 0.0 0.0 0.0 11.340 0.0 0.505 VeI= 6.56 207 -23.80 2.157 0.0 7.220 18.193 to 120 0.0 0.0 0.0 227 50.94 0.0219 0.0 7.220 0.158 Vet = 4.47 227 -25.51 2.157 0.0 11.160 18.351 to 120 0.0 0.0 0.0 208 25.43 0.0061 0.0 11.160 0.068 Vel= 2.23 208 0.0 1.38 4T 24.0 187.290 18.419 to 120 0.0 24.000 0.0 I 209 25.43 0.0534 0.0 211.290 11.276 Vel = 5.45 209 0.0 2.635 0.0 11.160 29.695 to 120 0.0 0.0 0.0 I 210 25.43 0.0022 0.0 11.160 0.025 Vel = 1.50 210 25.51 2.635 0.0 7.220 29.720 to 120 0.0 0.0 0.0 ' 211 50.94 0.0083 0.0 7.220 0.060 Vel = 3.00 211 23.80 2.635 0.0 11.340 29.780 to 120 0.0 0.0 0.0 I 212 74.74 0.0168 0.0 11.340 0.191 Vel= 4.40 212 25.33 2.635 0.0 11.330 29.971 to 120 0.0 0.0 0.0 213 100.07 0.0288 0.0 11.330 0.326 Vel = 5.89 I 213 39.76 2.635 0.0 6.260 30.297 to 120 0.0 0.0 0.0 214 139.83 0.0537 0.0 6.260 0.336 Vel = 8.23 I 214 46.88 2.635 0.0 7.540 30.633 to 120 0.0 0.0 0.0 206 186.71 0.0914 0.0 7.540 0.689 Vel = 10.98 I 206 47.64 2.635 IT 16.474 5.920 31.322 to 120 0.0 16.474 0.0 205 234.35 0.1392 0.0 22.394 3.118 Vel = 13.79 I 0.0 234.35 34.440 K Factor= 39.93 I 201 31.27 1.38 4T 24.0 187.950 16.957 to 120 0.0 24.000 0.0 202 31.27 0.0782 0.0 211.950 16.581 Vet = 6.71 0.0 2.635 0.0 10.000 33.538 I 202 to 120 0.0 0.0 0.0 203 31.27 0.0033 0.0 10.000 0.033 Vel = 1.84 1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 11 BRESSI RANCH LOT 15 Date 7/21/08 Hyd. Qa Dia. Fitting Pipe Pt Pt • Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 203 31.35 2.635 0.0 9.660 33.571 to 120 0.0 0.0 0.0 I 204 62.62 0.0121 0.0 9.660 0.117 Vel = 3.68 204 50.13 2.635 IT 16.474 4.420 33.688 to 120 0.0 16.474 0.0 I 205 112.75 0.0360 0.0 20.894 0.752 Vel = 6.63 205 234.35 2.635 1 8.237 7.250 34.440 to 120 0.0 8.237 0.0 I TOR 347.1 0.2879 0.0 15.487 4.459 Vel = 20.42 TOR 0.0 3.26 0.0 14.670 38.899 to 120 0.0 0.0 6.354 I Ri 347.1 0.1021 0.0 14.670 1.498 Vel = 13.34 RI 0.0 3.26 2E 18.815 15.410 46.751 to 120 1Z 9.408 28.223 5.557 BOR 347.1 0.1021 0.0 43.633 4.455 Vel = 13.34 I BOR 0.0 6.16 1E 20.084 5.000 56.763 to 140 0.0 20.084 2.166 347.1 0.0035 0.0 25.084 0.087 Vel = 3.74 I A A 0.0 6.09 2E 43.166 97.000 59.016 to 150 0.0 43.166 0.0 BF2 347.1 0.0032 0.0 140.166 0.451 Vel = 3.82 I BF2 0.0 6.16 iT 43.037 16.000 59.467 to 140 2E 40.168 83.205 7.000 * Fixed loss = 7 BF1 347.1 0.0035 0.0 99.205 0.344 Vel = 3.74 I BF1 0.0 6.09 iG 4.625 22.000 66.811 to 150 iT 46.249 50.874 0.0 B 347.1 0.0032 0.0 72.874 0.235 Vel = 3.82 I B 100.00 7.98 2E 54.365 120.000 67.046 Qa = 100 to 150 IG 6.041 113.261 0.0 447.1 0.0014 iT 52.855 233.261 0.322 Vel = 2.87 I C C 0.0 9.79 6G 40.485 768.000 67.368 to 150 2T 134.949 205.122 0.0 TEST 447.1 0.0005 1 29.689 973.122 0.496 Vel = 1.91 I 0.0 447.10 67.864 KFactor= 54.27 I 1 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I AutoPeaking Summary INDUSTRIAL FIRE SPRINKLER CO. Page 12 BRESSI RANCH LOT 15 Date 7/21/08 Auto Peaking Summary - List of Pipes for Area Calculated I I Left Right Side Side I From To Length From To Length I I I 219 319 35.670 218 313 35.830 I 216 301 35.500 215 I U I I I 307 35.750 322 213 129.670 318 214 113.830 306 204 113.500 312 206 113.750 Flow Pressure Pressure Required Required Differential Left 8.000 I 447.724 67.770 -0.094 Area Calculated I 447.099 67.864 0.000 I Right 8.000 I 446.435 67.849 -0.014 - Typical Distance Between Heads = 8.000 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I AutoPeaking Summary Split Point Used in Worst Area Peaked = 315 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 _ Fie S pn FlexHe ead® Commercial Ceiling der Connections lead sprinklers allow engineers, architects, contractors and building owners a ree of versatility previously unavailable. With so many options, they make it design and work with whatever configuration your plans call for. Fits and features incLude: iced manpower, labor costs, call-backs -track construction for rapid / building occupancy 'Quick retrofit of existing buildings 'Predictable installation that r / / eliminates bidding problems or 7 / missed schedules / • Easy installation of semi-recessed, \ / fuLLpendant,. or fully concealed sprinkler head NI 'Multi-port bracket for perfect FlexHead Metal Stud Detail Sprinkler branchline FlexHead sprinkler drop Adjustable hub... Metal stud Materials Hose Assembly - ALL 304 Stainless Steel Multi-port Bracket - HO G60 Galvanized Metal Multi-port metal stud mounting bracket Sheetrock ceiling - ,- .... unirorm ty with any suspended or sheetrock ceiling system 'Meets International Building Code (IBC) and NFPA guidelines 'Meets ASCE 7-98 guidelines for seismic design categories C, 0,. E and F referenced in the IBC 'Approved for use in suspended ceilings with light, medium, and heavy-load grids (ASTP.l C635, 636) Industrial grade, all-welded, no 0-ring construction 'Rated up to 300psi and requires no hangers 'Easy friction loss/water pressure ' calculations Sprinkler head FlexHead Suspended Ceiling Detail Each FM-approved unit is ready-to-install pressure- and teak-tested, and comes complete with a flexible stainless-steel jrF ad hose and mounting bracket with adjustable hub. drop Multi-port ceiling grid rl mounting bracket ..-Adjustable hub Suspended t-bar grid Ceiling tile Sprinkler head Sprinkler branchline FlexHead Outlet Hose Assembly Equivalent Length of 1" Maximum Rated Model # Size Length ft(m) schedule 40 pipe ft(m) Pressure psi (kPa) 2024 1/2in. 2ft (06m) 17ft (5dm) 175 (1205) 2036 1/2in. 3ft (09m) 22ft (6.6m) 175 (1205) + 2048 1/2in. 4ft (1.2m) 24ft (73m) 175 (1205) 2060 1/2in. 5ft (1.5m) 25ft (7.5m) 175(1205) 2072 1/2in. 6ft (1.8m) 28ft (8Am) 175 (1205) T. 2024 3/4i n. 2ft (06m) 9ft (2.7m) 175 (1205) 2036 3/4i n. 3ft (0.9m) 16ft (4.8m) 175 (1205) 2048 3/4i n. 4ft (1.2m) 21ft (6Am) 175 (1205) 2060 3/4i n. sft (1.5m) 22ft (6.6m) 175 (1205) 2072 3/4in. 6ft (1.8m) 25ft (7.5m) 175 (1205) FlexHead products are intended for use in hydraulically designed wet, pre-action, deluge or dry pipe sprinkler systems per NFPA 13, 13R and 130 guidelines. The hydraulic loss of the Flexllead needs to be included in the hydraulic design calculations the some as a valve of fitting. Each FlexHead has a 3' minimum bend radius per UL guidelines and a 7" minimum bend radius per FM guidelines. PRODUCT NAME MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS tlhe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com PRODUCT DESCRIPTION August 4, 2006 Sprinkler 41 a Viking Microfast® and MicrofastH P® Quick Response Pendent Sprinklers are small thermosensitive glass bulb spray sprinklers I available in various finishes, temperature ratings, and orifice sizes to meet design requirements. The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) I The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern I to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS I cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 41 c and Design Criteria on page 41 d for cULus and FM approval requirements that I must be followed. CHARACTERISTICS Minimum Operating Pressure: 7 psi (0,5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C 19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Note: Units of measure in parentheses may be approximations Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 °F temperature rating, and added CE approval for sprinkler 06666B.) I I Sprinkler 41 b August 4, 2006 Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color cIas Temperatureon Temperature Rating' ceiling Toirip.r,ituie U C or Ordinary 135°F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinkler 06662B), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® Corrosion-Resistant Coatings3: White Polyester (White Poly finish for Sprinkler 06662B only), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page 41 c. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Poly finishes and Teflon® coatings. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sprinklers: Belleville Spring-Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table 1 above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list.) Order Microfast® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Poly Finish = M-/W, Black Poly Finish = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, Sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB. ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W/B. **A 1/2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) I El I I I I I I I El I I I I I I I I U August 4, 2006 Sprinkler 41 c MICROFASTO AND QUICK RESPONSE PENDENT SPRINKLERS Approval Chart ..-: KEY MIcrofast and MicroIastHP°Quick Response Pendent Sprinklers [;x4 Maximum 175 PST (12,1 bar) WWP Base Part Thread Size Nominal I Overall Length Listings and Approvals3 Number' b r1 SIN K-Factor (Refer also to Design Criteria on page 41 d) NPT BSP U.S. I metric2 Inches mm cULus4 FM5 NYC' VdS LPCB CE I Standard Orifice 06662B I VK302 1 1/2" 115 mm 5.6 I 80,6 I 2-1/4 I 58 JA1X, B1YIA4X, B4YIA1X, 131YI F2_1 A4X IC4X, D4Y121 C4X, D4Y14 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115,2 2-3/8 60 IA3X,B3YIA2X,B2Y A3X, B3Y -- -- E412 -- 12104 VK352 3/4" 120 mm 8.0 1 115,2 1 2-1/4 58 1 F2 -- -- -- 06765B VK352 1/2" 15 mm 8.0 115,2 2-3/8 60 A3X, B3Y -- A3X, B3Y1 -- -- -- _________ Small Orifice8 06718139 VK329 1/2" 15 mm 2.8 40,3 2-3/16 56 A3X, B3Y A2X A3X, B3Y -- -- -- -- 06720139 VK331 1/2" 15 mm 4.2 60,5 1 2-1/4 58 JA3X,B3Y -- A3X,B3YI I -- -- -- 06932B VK331 -- 10mm 4.2 60,5 1 2-3/8 60 1 -- -- -- F2 I F213 -- Maximum 250 PSI (17,2 bar) WWP Standard Orifice Base Part Thread Size Nominal Overall Length Listings and Approvals u Number' SIN K-Factor (Refer also to Design Criteria on page 41 d.) NPT BSP U.S. metric2 Inches I mm cULus4 I FM I NYC10 JVdSJLPCBJ (( 12282 VK317 1/2" 115 mm 5.6 80,6 1 2-1/4 1 58 A3X, 133Y -- A3X -- -- -- -- Maximum 250 PSI (17,2 bar) WWP Small Orifice8 122909 1 VK342 1/2" 115 mm 1 2.8 1 40,3 2-3/16 I 56 IA3X, B3YI -- I A3X -- Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), Approved Escutcheons 200 °F (93 °C), and 286 °F (141°C) Approved Finishes x - Standard surface-mounted escutcheon B-135°F(57°C), 155°F(68°C),175°F(79"C), 1 - Brass, Chrome-Enloy®, White Poly Finish 7, or the Viking Microfast® Model F-i and 200 °F (93 °C) Black Poly Finish 7, and Black Teflon 07 Adjustable Escutcheon" C -155°F (68 "C), 175°F (79 °C), 200°F (93 "C), 2 - Brass and Chrome-Enloy® Y - Standard surface-mounted escutch- and 286 °F (141°C) 3 - Brass, Chrome-Enloy®, White Polyester7, eon or the Viking Microfast® Model D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Black Polyester 7, and Black Teflon 07 F-i Adjustable Escutcheon" or re- (93 °C) 4 - Brass, Chrome-Enloy®, White Poly Finish, cessed with the Viking Micro- E - 155 °F (68 °C), 175 °F (79 °C), and 286 °F and Black Poly Finish matic® Model E-1 or E-2 Recessed (141°C) Escutcheon F - 155 °F (68 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI. The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13(( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130. 14.0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. I I I I I I I I I I 11 I I I I I [ IN I mvun Wrench 12144W/B** for installing coated and/or recessed sprinklers J, with protective caps. Carefully slide the wrench sideways around the protective **A 1/2" ratchet is required cap, ensuring engagement (not available from Viking). with the sprinkler wrench flats. Figure 2: Wrench 12144W/B for Installing Coated and/or and Recessed Pendent Sprinklers Sprinkler 41 d August 4, 2006 r ri MIr'pOAT® AND NjJJ00 QUICK RESPONSE PENDENT SPRINKLERS DESIGN CRITERIA (Ao refer to the Appova: Chart on page 41 ç cULus Listing Requirements: Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Approval Requirements: Quick Response Pendent Sprinklers are FM Approved as indicated in the Approval Chart for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Flat Wrench Protective Sprinkler Cap 9:=0R= Figure 1: Standard Sprinkler Wrench 10896W/13 I I I I Li I I August 4, 2006 Sprinkler 41 e Ceiling Opening Size: 2-5/16" (59 mm) Minimum, I 21/8 I 2-1/2" (64 mm) Maximum. (54 mm) 1/2" ,, ________ AN (15 mm, 7 mm) Mini um (445 fllrfl) Maximum Pendent Sprinkler 066628 Installed Pendent Sprinkler 06662B with a Standard 1/8" (3,1 mm) Pendent Sprinkler 06662B Surface-Mounted Escutcheon Installed with the Microfast Model F-i Adjustable Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 2-1/8" 2-5/16" (59 mm) Minimum, - 2-1/8" (54 mm) 2-1/2" (64 mm) Maximum. (54 mm) 1-3/4" 1-1/8" (28,6 mm) (44,5 mm) Minimum Maximum Pendent Sprinkler 066628 t 2" 1-1/8" (28,6 mm) (50,8 mm) Minimum Maximum Ma Installed with the Micromatic® Pendent Sprinkler 06662B Model E-i Recessed Escutcheon Installed with the Micromatic® Model E-2 Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons El I I I I THIS PAGE INTENTIONALLY LEFT BLANK I Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 °F temperature rating, and added CE approval for sprinkler 06666B.) March 7, 2008 Sprinkler 52a MICROFAST® AND MICROFASTHP® QUICK II1F1G RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer to the Approval Chart on page 52d and Design Criteria on page 52e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinkler VK344 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprin- klers can be identified by locating "250" stamped on the deflector. Sprinklers VK304, VK333, and VK335 are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. I Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bushing (for sprinklers VK333 and VK344): Brass UNS-C36000 I Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 I Pip Cap Attachment (for sprinklers VK333 and VK344): Brass UNS-C36000 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed I Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N I Temperature Suffix (°F/°C): 135°/68° = A, 155°/680 = B, 175°/79 = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK304 with a Brass finish and a 155 °F/68 °C temperature rating = Part No. 06725BAB Form No. F080688 Replaces page 52a-f, dated February 2, 2007. (Added I Dry System note in approval chart for Small Orifice) I I Sprinkler 52b MICROFAST® AND MICROFASTHP® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLERS March 7, 2008 The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories' section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) **A 1A" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Wrench Sprinkler © Flo:l: Shield I 0=8 9 6 70)) Figure 1: Standard Sprinkler Wrench 10896W113 I I I I Li I Li I I I I Li I I I I I March 7, 2008 Sprinkler 52c MICROFAST® AND MICROFASTHP@ QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Sprinkler Temperature Sprinkler Nominal Maximum Ambient 3tith Color Classification , Temperature Rating' Ceiling Temperature' Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 00) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F(141°C) 225°F(107°C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. Sprinkler Wrench Part No, 13655V/B* or Recessed Horizontal Sidewall Sprinklers Fit the wrench over the sprinkler and protective shield as shown. - — --1 I - / /r \\\ I I (I I I II jj II I - ----------1 -Li L__-' ?iENote: A 1/2" ratchet is required. (Not available from Viking.) Figure 2: Wrench 13655W/B for Recessed Horizontal Sidewall Sprinklers I I I I I I I I I I I I I I I I I I I March 7, 2008 The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Approval Chart rKEYi Microfat and MiorofastHP1,1 Quick Response Horizontal Sidewall Sprinklers [A For Light Hazard Occupancies Only - Maximum 175 PSI (12 Bar) WWP Standard Orifice, Deflector must be located 4" to 6" (102 mm to 152 mm) below the ceiling. Base Part Maximum Thread Size Nominal Overall Length Listings and Approvals' Number' SIN Pressure K-Factor (Refer also to Design Criteria on pg 52e.) NPT BSP U.S. metric2 1 Inches mm cULus4 FM5 NYC' LPCB (E • 06725B VK304 175 psi 1/2" 15 mm 5.6 80.6 2-1/2 64 A1Y, B1Z A2Y A1Y, B1Z -- -- -- ________ Standard Orifice,Deflector must be located 6" to 12" (152 mm to 304 mm) below the ceiling. -- A1Y -- -- -- 06725B VK304 175 psi 1 1/2" 1 15 mm 1 5.6 1 80.6 [ 2-1/2 1 64 1 A1Y I _________ Small Orifice", Deflector must be located 4" to 6" (102 mm to 152 mm) below the ceiling. Base Part Maximum Thread Size Nominal Overall Length Listings and Approvals3 Number SIN Pressure K-Factor (Refer also to Design Criteria on pg 52e.) NPT BSP U.S. metric2 Inches mm cULus4 FM NYC" LPCB (E 4 10035 VK333 175 psi 1/2" 15 mm 2.8 1 40.3 2-1/2 64 A1Y, 131Z -- A1Y -- -- -- 08983 VK335 175 psi 3/8" 10 mm 4.2 60.5 1 2-1/2 64 -- -- -- -- -- -- Maximum 250 PSI WWP Small Orifice', Deflector must be located 4" to 6" (102 mm to 152 mm) below the ceiling. 12287 VK344 250 psi 1 1/2" 1 15 mm 1 2.8 1 40.3 1 2-1/2 1 64 A1Y, B1Z -- A1Y -- -- -- Approved Temperature Ratings Approved Escutcheons Approved Finishes Y - Installed with standard surface-mounted escutcheons or A - 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-i Adjustable Escutcheon (79 °C), 200°F (93 °C), and 286 OF (141 °C) ester", Black Polyester10, and Black Z - Installed with standard surface-mounted escutcheons or B - 135 OF (57 °C), 155 OF (68 °C), 175 OF Teflon040 the Viking Microfast® Model F-i Adjustable Escutcheon, (79 °C), and 200 OF (93 °C) 2 - Brass and Chrome-Enloy® or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use in wet pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. 10cULus Listed as corrosion-resistant. "The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. I I I LI I I I I I I I I I I I I March 7, 2008 Sprinkler 52e The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA Also iefOr to the Approva' Chan on page 52d cULus Listing Requirements: Microfast® and MicrofastHP11 Quick Response Horizontal Sidewall Sprinklers are cULus Listed as indicated in the Approval Chart for installation in ac- cordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Limited to Light Hazard occupancies only (small orifice sprinklers are limited to Light Hazard Occupancies with hydraulically calculated wet systems only). Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Refer to the Approval Chart for allowable deflector distance below the ceiling. Align with the leading edge of the deflector parallel to the ceiling. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. Minimum distance from end walls is 4 in. (102 mm). The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. FM Approval Requirements: Microfast Quick Response Horizontal Sidewall Sprinkler VK304 is FM Approved, as indicated in the Approval Chart, for use in wet pipe sprinkler systems (or preaction systems qualifying as wet systems) in Light Hazard occupancies only. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. ut1 Opening Size: 2-5/16' (58,7 mu) minimum 2-1/2' (63,5 mm) maximum 2—i,'4' I (57 mm) (48 mm) 21/2 Minimum (63,5 rw'i) Me ?' (32 mm) < 1/2 1 P U 2-7/16 (15 mm) HSW Sprinkler kir. Installed with the (62 ) NPT 06725B (Vk304) 1/8 (31 mm) standard surface-mounted escutcheon Maximum Installed with the Mlcrofast Model F—i Acjustab1e Escutcheon Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon I I I I I I I I I I I I I I I I I I I Sprinkler 521 March 7, 2008 The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Wall Opening Size: 2-5/16" (57.2 mm) minimum 2-1/2" (63,5 mm) maximum 1-7/16" 1-7/16" (36.5 ) (36.5 mm) Minimum Minimum I::JJ 2-1/16" 2-1/4" (52 mm) (57.2 mm) Maximum Maximum Installed with the Micr-omatic Installed with the Threaded Model E-1 Recessed Escutcheon Model E-2 Recessed Escutcheon Figure 4: Sidewall Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F080688 Replaces page 52a-f, dated February 2, 2007. (Added Dry System note in approval chart for Small Orifice) Sprinkler Base Part No. 09849 Sprinkler Base Part No. 10224 December 1, 2006 Sprinkler 14e IF4Ir'G; MICROMATIC® AND MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com DESCRIPTION Viking Micromatic® and MicromaticHP® Standard Response Horizontal Sidewall I Sprinklers are small thermosensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are de- sired. In addition, these coatings have been investigated for installation in corrosive I atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) I Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page 14f. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2012 Refer to the Approval Chart on page 14g and Design Criteria on page 14h for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers VKII6 and VK0I5 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http:llwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bushing (for high pressure sprinkler 09997): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap: Copper UNS-C31600 or UNS-C31400 for Sprinklers 10171 and 10224. For all others: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment (for sprinklers 09849 and 09997): Brass UNS-C36000 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed I Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. I Form No. F_123096 Replaces page 14e-f, dated November 18, 2005 (reformatted and renumbered.) I I I I I Sprinkler 14f I December 1, 2006 Wren nat ch Protective j jr Inkter Shield The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 I Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N, Wax Coated = C, Wax Over Polyester = V-/W I Temperature Suffix (°F/°C): 135°/68° = A, 155°/68° = B, 175°I79° = D, 2000/930 = E, 212"/100° = M, 286°/141° = C, 360°I182° = H, OPEN = Z (Teflon® only). For example, sprinkler VK104 with a 1/2" thread, Brass finish and a 155 °F/68 "C temperature rating = Part No. 10224AB I Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) Wrench for wax coated sprinklers: Part No. 13577W/B** (available since 2006) **A %" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Standard Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/B Sprinkler Wrench Part No. 13655\.//B* for Recessed Horizontal Sidewall Sprinklers Protective Fit the wrench over the sprinkler Sprinkler and protective shield as shown, Shield A —M r-L ---------- Ii \ - H_J ----------- eNote A 1/2' ratchet is required (not avail- able from Viking). Figure 2: Wrench 13655W/B for Recessed Horizontal Sidewall Sprinklers Carefully press the wrench onto the sprinkler wrench flats, *A 1/2' ratchet Is required er \Jrench (not available from Viking). 13577W/Bww for Installing wax coated sprinklers Figure 3: Wrench 13577W/13 for Wax Coated Sprinklers December 1, 2006 Sprinkler 14g MICROMATIC® AND MICROMATICHP® STANDARD IIM flt RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com !lnklerTem!ra!o,Spn!Nomi;aI.M!umAmb!ent Classification Temperature Rating' Ceiling Temperature, t or Ordinary 135 OF (57 °C) 100 OF (38 °C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 OF (79 °C) 150 OF (65 00) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Extra High 360°F (182 °C) 300°F (149 °C) Mauve Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Polyester for sprinklers with the following temperature ratings: 135 OF (57 °C) Off-White Wax 155 OF (68 °C) Lt. Brown Wax 175 OF (79 °C) Brown Wax 200 OF (93 °C) Brown Wax 286 OF (141 °C) Dk. Brown Wax Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. I I I I I I I I I I I I I I I I I 1 I Sprinkler 14h December 1, 2006 Wa MICROMATIC®AND 11L\ EWA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com r 14tl; Kl Approval Chart Mirmatic and MicromaticHP Standard Response Horizontal Sidewall Sprinklers [Al X'. _ .r tfl6p0 Maximum 175 PSI (12 Bar) WWP (See Footnotes Below for Allowable Deflector Distance Below the ceiling.) Base Part Maximum Thread Size Nominal I Overall Length Listings and Approvals3I Number' SIN Pressure I K-Factor i (Refer also to Design Criteria on pg 141.) I NPT BSP I U.S. metric2 Inches mm I cULus4'5 FM- NYC' LPCB I CE 10 II I I Standard Orifice 10224 I VK104 I 175 psi 1/2' 15 mm I 5.6 80.6 2-7/16 1 62.4 1 B5X, B1X, A1Y, C6Y A3Y I B5X, B1X, Al Y, C6Y I D3Z, E4Z D2Z D2Z 10171 VK104 175 psi -- 15 mm -- 80.6 2-7/16 { 62.4 Small Orifice 09126 VK016 175 psi -- 10 mm 4.2 60.5 2-7/16 [ 62.4 cULus FM NYC LPCB CE Maximum 250 PSI (17 Bar) WWP Standard Orifice, for Installation 4" to 12" (102 mm to 305 mm) Below the Ceiling. 09849 VK116 250 psi 1/2" 15 mm I 5.6 80.6 I______________________________________ 2-11/16 I I 67.6 I cULus",- I I FM I NYC I LPCB I CE I I AIY, B1X -- -- -- I I -- I I -- I Maximum 250 PSI (17 Bar) WWP Small Orifice0, for Installation 4" to 6" (102 mm to 152 mm) Below the Ceiling. 0999712 VK015 250 psi 1/2" 15 mm 2.8 40.3 2-3/4 I I 69 I cULus4'9 I FM I NYC I LPCB CE I Approved Temperature Ratings Approved Finishes Approved Escutcheons 1 - Brass, Chrome-Enloy®, White PoIyester 14, Black Poly- A 135°F (57 °C), 155°F (68 °C), 175°F ester1314, and Black Teflon®13 (79 °C), 200°F (93 °C), 286°F (141 °C), 2 - Brass, Chrome-Enloy®, White Polyester, and Black Poly- x - Installed with standard surface-mounted es- and 360 °F (182 °C) ester cutcheons or the Viking Microfast® Model B - 135°F (57 °C), 155°F (68 °C), 175°F 3 - Brass and Chrome-Enloy® - F-i Adjustable Escutcheon15, or recessed (79 °C), and 200 °F (93 °C) 4 - Wax-Coated Brass (corrosion resistant), White Poly with the Viking Micromatic® Model E-1 or E-2 C - 286 °F (141 °C) ester, and Black Polyester Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), 200 °F 5 - Wax-Coated Brass and Wax Over Polyester (corrosion Y - Installed with standard surface-mounted es- (93 °C), 286 °F (141 °C), and 360 °F resistant) cutcheons or the Viking Microfast® Model F-i (182 °C) 6 - High Temperature 200 °F (93 °C) Wax Coating (corro- Adjustable Escutcheon15 E - 155 °F (68 °C), 175 °F (79 °C), and sion resistant); maximum ambient temperature allowed Z - Installed with standard surface-mounted es- 200 °F (93 °C) at ceiling = 150 °F (65 °C) cutcheons only Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2Metdc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listings limited to Light Hazard Occupancies where allowed by the installation standards being applied, with the deflector 4" to 12" (102 mm to 305 mm) below the ceiling. 6 F Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with the deflector 4" to 6" (102 mm to 152 mm) below the ceiling. 7Approved by the New York City Board of Standards and Appeals under Calendar Number 219-76-SA. 8 cULus Listed for Light Hazard Occupancies where allowed by the installation standards being applied, and Ordinary Hazard Group I and II Occupancies. cULus Listings limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet sys- tems. 10 (( Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. ' c MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. The sprinkler orifice is bushed. 13cULus Listed as corrosion-resistant. "Other colors are available on request with the same Listings and Approvals as the standard colors. "The Viking Microfast' Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. I I ~ I I I I L LI I I I I I I I I I I I I I I I I I I I I I I December 1 2006 Sprinkler 14i The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA tAlso ref'r to the Approvai Chan on page 14h cULus Listing Requirements: Standard Horizontal Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in occupancy hazard classifications as indicated in the approval chart, below smooth, fiat ceilings only. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. FM Approval Requirements: Standard Horizontal Sidewall Sprinklers are FM Approved for Light Hazard occupancies only, as indicated in the Approval Chart, for installation in ac- cordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Wall Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-11/16" (68.3 mm) 1/2" 1.8'mm) (15 mm) MDT Fff 2-1/4" HSW Sprinkler VK1 16 Lii (57.2 mm) Maximum HSW Sprinkler VK116 Installed with a standard HSW Sprinkler VK1 16 1/8" (3.1 mm) surface— Installed with a Micromatic mounted escutcheon. Model E-1 Recessed Escutcheon. Figure 4: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 1-5/8" (41.3 mm) Minimum Sprinkler 14j December 1, 2006 The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Wall Opening Size; 7-5/1 6" (58.7 mm) minimum 2-1/2" (53.5 mm) maximum 7-1/16" 2-1/16" (52.4 mm) Minimum H Minimu 2 1/8" - - - __f (b4 mm) (66.7 mm) (73 mm) Maximum Maximum Sprinkler VK1 16 Sprinkler VK1 16 Installed with a Microfast Installed with a Model —7 Model 1-1 Adjustable Iscutcheon. Thread—on Recessed rscufchean Figure 5: Sidewall Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_123096 Replaces page 14e-f, dated November 18, 2005 (reformatted and renumbered.) I I PRODUCT NAME MICROMATIC® AND MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS NOTE: The Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcsvikingcorp.com PRODUCT DESCRIPTION I I I I I August 4, 2006 Sprinkler 11 q Viking Micromatic®and MicromaticHP®Standard Response Uprightand Conventional Sprinklers are small thermosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meetdesign requirements. The special Poly finishes andTeflon®coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for installation in corrosive atmospheres and are CU Lus listed as corrosion resistant as indicated in theApproval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page 11 r-s. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2001, 2002, and 2016 Refer the Approval Chart on page 11 t and Design Criteria on page 11 s for cULus and FM approval requirements that must be followed. CHARACTERISTICS Minimum Operating Pressure: 7 psi (0,5 bar) I . Maximum Working Pressure: Upright Sprinklers VK02I and VK124 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above I are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 I . Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) I Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 I Deflector: Copper UNS-C19500 for Sprinklers 10138, 10141, 10169, 10174, 10190, 10193, 10220, 10233, and 12106. Note: Units of measure in parentheses may be approximations. New page 11 q-t, issued August 4, 2006 (information Form No. F_080106 was previously on data page 11 a-d). I I I I I L I I Sprinkler 11 r August 4, 2006 pffiv 75 Sprinkler Temperature Sprinkler Nominal + Maximum Ambient Classification Tmperatuie Rating' ' Ceiling Temperature Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 F (68 C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 C) Green Intermediate 212 ¶ (100 C) 150 F (65 °C) Green High 286 °F (141 °C) 225 ¶ (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 C) Mauve Ultra High 500 °F (260 °C) 465 °F (240 C) Black Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinklers 10138, 10141, and 10220), Black Polyester (Black Poly finish for Sprinkler 10138), and Black Teflon® Corrosion-Resistant Coatings3: White Polyester (White Poly finish for Sprinklers 10138, 10141, and 10220 only), Black Polyester (Black Poly finish for Sprinkler 10138), and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Polyester finish5 for sprin- klers with the following temperature ratings: 135 °F (57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page lit. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Poly finishes and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. ' Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating tempera- tures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 AC), response time may be severely retarded. Wax Over Polyester is unavailable for Sprinklers VK021 and VK124. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09995, 10191, 10192, 10218, and 10219): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09993 and 09995: Bronze UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12106): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sprinklers: Belleville Spring-Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table 1 above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list.) I Order Micromatic® Standard Response Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A, Chrome-En by® = F, White Poly Finish = M-/W, Black Poly Finish = M-/B, Black Teflon® = N, Wax Coated = C, Wax Over Polyester = V-/W. U I I I I I I I U I I I I I I El I August 4, 2006 Sprinkler 11 s mn ,ri F MICROMATIC®AND MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS Temperature Suffix (°FI°C): 135°/68° = A, 155°/68° = B, 175°/79° = D, 200/93° = E, 212°/100° = M, 286°/141° = 360°I182° = H, 500°/260° = L, OPEN = Z (Teflon® only). For example, Sprinkler VK100 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 10138AB. ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for wax-coated sprinklers: Part No. 13577W/B** (available since 2006) **A %" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) Sprinkler Wrench 13577 W/B** for installing wax Protective coated sprinklers. Wrench Sprinkler Step 1: Carefully slide I Flat Cap the wrench sideways ) I MEW around the deflector, ..- / ensuring engagement ./ I I with the sprinkler wrench flats. Wax Coated—" 10896 Upright Sprinkler i Step 2: Carefully press the wrench **A 1/2" ratchet is required downward and ensure engagement Figure 1: Standard Sprinkler (not available from Viking). with the sprinkler wrench flats. Wrench 10896W/13 Figure 2: Wrench 13577W/B for Wax Coated Sprinklers DESIGN CRITERIA AIsc cetec to t'o Approval Chart on. paq 1 t, cULus Listinç Requirements: Standard Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conven- tional) sprinklers. Standard spray sprinklers are designed for use in Light, Ordinary, and Extra Hazard occupancies (exception: small ori- fice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For con- ventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. FM Approval Requirements: Standard Upright Sprinklers are FM Approved as indicated in the Approval Charts for installa- tion in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. I I LI I U I I I I U U I I U U I I I Sprinkler 11 t August 4, 2006 N fJJ D"1A' MICRONIATIC® AND MicromaticHP® STANDARD ' RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS Approval Chart Micrornatic and MicrornaticHP Standard Response Upright and Conventional Sprinklers A1X ± Maurnsrn 175 PSI (12.1 bar) WWP Base Part I l I Thread I Nominal Overall Listings and Approvals3 Number1 I SIN I Size K-Factor Length (Refer also to Design Criteria on page 11 s.) I INPTI BSP U.S.Imetric21lnchesjmm: clJLus4 I FM NYC VdSI LPCB ICE I j4pright-Standard_Orifice 10138 lVK100I1/2" 15 mm 5.6 80,6 i23/i6TS6 B14, Ell, F13,G9Ai5,Dl2,015 814, Ell. F136 1 .. -- I 10233 IVK145I 1/2" 15 mm 5.6 80,6 I 2-3/16t56 1 A8, D7, G8 -- B6 B9, E3 IH612 flT7 10174 IVK145I -- 15 mm 5.6 80,6 .2-3/16156 -- A8, D7, G8 -- -- B9, E3 I -- 10193 IVK100I -- mm 5.6 80.6 2-3/16156 1 Bi, E10, F13, G9 A8, D7, G8 I Bi, E10, F136 -- I -- I -- ______ _UDright-Large_Orifice 10220 IVK200l1/2" 15 mm 8.0 115,2 1 2-3/8 60 1 B2, Eli, F13, G9 B8, E12, G8 B2, E116 -- I H9121 H914 10141 lvK200 3/4"120 mm 1 8.0 115,2 1L16 59 1 B2, Eli, F13, G9 B8, E12, G8 B2, Eli, F136 B6 B5, Eli 1H912 H9M 10190 IVK2001 -- 15 mm 8.0 115,2 1 2-3/8 60 Bi, El 0, F13, G9 B8, E12, G8 -- -- IH912 1 H 91 10169 IVK200l -- 120 mm 1 8.0 115,2 '2-5/16 59 Bi, E1O, F13 B8, E12, G8 -- - B9, E3 IH912 I jT Uright-Small Orifice8 102189 lVK001l1/2" 15mm 2.8 4013 i 2-3/16 56 Bl,EIO,Fl3 E9, E12 -- -- -- -- 10219 IVK002I1/2" 15mm 42 60,5 r2-3/16 56 1 Bl,E1O,F13 -- -- -- -- -- 10191 IVk002I -- 15mm 4.2 60,5 2-3/16 56 B1,EIO,F13 -- -- -- -- -- -- 70192 IVK601I -- 15mm 2.8 40,3 2-3/16 56 1 Bl,E1O,F13 -- -- - -- -- -- 10176 IVK002I -- 10mm 4.2 60,5 12-3/16 56 1 E9, E12 -- 85 B9, E3 H512 H514 Conventional 10227 VK118I1/2" 15mm 5.6 80,6 2-3/16 56 B1,Ei0,F13 -- Bl,E10,F13° B5 B5,E10 H512 H514 10228 VK120I3/4" 20 mm 8.0 115,2 2-5/16 59 B11 E10,F13 -- B1,E10,F13U -- 85,E10 j2 1017210 VK1181 -- 15mm 56 8016 2-3/16 56 Bl, E10, F13 -- -- -- B5, E10 -- -- 1016810 VK120I -- 2O mm 8.0 11512 2-5/16 59 i Bl, E10, F13 -- -- - B5, E10 H912 H914 12106 VK120I3/4" 20 mm 8.0 115,2 2-5/16 59 1 -- H513 Maximum 250 PSI (17,2 bar) WWP Upright-Standard Orifice 09993 1VKi24I1/2"I15mmI 5.6 I 80,6 i 2-1/4 1 58 i Cl I -- I -- -- I -- I -- -- _____________________________________________ Upright-Small Orifice8 099951 IVK021I1/2"I15mmI 2.8 I 40,3 2-1/4 58 1 Cl -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C), 175°F (79 °C), 1- Erass, Chrome-Enloy®, White Polyester5, Black Polyester5 and Black Teflon05 200 °F (93 °C), 212 °F (100 °C), 286 °F (141 °C), 2 - Erass, Chrome-Enloy®, White Poly Finish5, Black Polyester5, and Black Teflon65 - White Polyester, Black Polyester, Black Teflon®, Wax-Coated Brass, and Wax °F °C) and 360 (182 ever Polyester B -135°F (57 °C), 155 °F(68 °C), 175 °F(79 ac:., 200°F 4 - White Poly Finish, Black Polyester, Black Teflon®, Wax-Coated Brass, and Wax over (93 °C), 286 °F (141 °C), and 360 °F (182 CC) Polyester C - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C, 200°F 5 - Erass, Chrome-Enloy®, White Polyester, and Black Polyester 6- Erass, Chrome-Enloy®, White Poly Finish, and Black Polyester °C), °F °C) (93 and 286 (141 7 - White Poly Finish and Wax-Coated Brass (corrosion resistant) D - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C, 200°F 8 - Erass, Chrome-Enloy® and White Poly Finish (93 °C), and 212 °F (100 °C) 9 - Erass and Chrome-Enloy® E - 135°F (57 °C), 155 °F (68 °C), 175°F (79 °C), and 10-Wax-Coated Brass and Wax over Polyester5 li-Wax-Coated Brass and Wax over Poly Finish5 200 °F (93 °C) 12-Wax-Coated Brass (corrosion resistant) F - 286 °F (141 °C) 13-200 °F (93 °C) High-Temperature Wax Coating (corrosion resistant); maximum G - 500 °F (260 °C)7 ambient temperature allowed at ceiling = 150 °F (65 °C) H -155 °F(68 °C), 175 °F(79 °C), 200 °F(93 °C, 286°F 14-Erass, Chrome-Enloy®, White Poly Finish5, Black Poly Finish5, and Black Teflon05 15-Erass, Chrome-Enloy®, White Poly Finish, and Black Poly Finish °C), (141 and_360_°F_(182_°C) _ Footnotes Base part number is shown. For complete part number, reer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Accepted for use, City of New York Department of Buildinçs, MEA Number 89-92-E, Vol. XII. Sprinklers of Ultra-High temperature rating are intended fcr use inside ovens, dryers, or similar enclosures with normal operating tempera- tures above 300 °F (149 °C). Where the anbient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-Higi temperature rated sprinkler may be severely retarded. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. The sprinkler orifice is bushed. 10Sprinklers 10168 and 10172 are available on special order. °Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. III. 12 ((Certified, Standard EN 12259-1, EC-certificate of conlormity 0832-CPD-2001 and 0832-CPD-2003. 13 ((Certified Standard EN 12259-1 EC-certificate of contormity 0786-CPD-40142. 14 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008. I New page ii q-t, issued August 4, 2006 (information Form No. F_080106 was previously on data page 11 a-d). I L I Li [I I El I