HomeMy WebLinkAbout1891 RUTHERFORD RD; 150; FPC2018-0329; Permit(7-city 0f
PERMIT REPORT Carlsbad
Print Date: 02/09/2022 Permit No: FPC2018-0329
Job Address: 1891 RUTHERFORD RD, # 150, CARLSBAD, CA 92008-7327 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm
Parcel #: Track #: Applied: 10/03/2018
Valuation: $0.00 Lot #: Issued: 10/25/2018
Occupancy Group: Project #: Finaled Close Out: 08/19/2021
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check #: Final Inspection:
Project Title:
Description: NAVIGATE BIOPHARMS EXPANSION TI -INSTALL (6) MANUAL INITIATING DEVICES
Applicant: FPContractor:
iii ENTERPRISES INC THE STEINHILBER CORPORATION
DANTE GOMEZ 533 S VINEWOOD ST
115 MARKET PL ESCONDIDO, CA 92029-1924
ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050
(760) 466-2707
FEE AMOUNT
FIRE TI Fire Alarm System $620.00
Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
-FC C, 0~~_q
DN-6726:D • H-240
2LX
Addressable Manual Pull Station INOTIFIER
The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e.,
requires two motions to activate the station) pull station that
includes an addressable interface for any Notifier intelligent
control panel except FireWarden series panels, and the NSF-
25 panel. Because the NBG-12LX is addressable, the control
panel can display the exact location of the activated manual
station. This leads fire personnel quickly to the location of the
alarm.
Features
Maintenance personnel can open station for inspection and
address setting without causing an alarm condition.
Built-in bicolor LED, which is visible through the handle of
the station, flashes in normal operation and latches steady
red when in alarm.
Handle latches in down position and the word 'ACTIVATED"
appears to clearly indicate the station has been operated.
Captive screw terminals wire-ready for easy connection to
SLC loop (accepts up to 12 AWG/3.25 mm2 wire).
Can be surface mounted (with SB-10 or SB-I/o) or semi-
flush mounted. Semi-flush mount to a standard single-
gang, double-gang, or 4" (10.16 cm) square electrical box.
Smooth dual-action design.
Meets ADAAG controls and operating mechanisms guide-
lines (Section 4.1.3[13]); meets ADA requirement for 5 lb.
maximum activation force.
Highly visible.
Attractive shape and textured finish.
Key reset.
Includes Braille text on station handle.
Optional trim ring (BG12TR).
Meets UL 38, Standard for Manually Actuated Signaling
Boxes.
Up to 99 NBG-12LX stations per loop on CLIP protocol
loops.
Up to 159 NBG-12LX stations per loop on FlashScan® pro-
tocol loops.
Dual-color LED blinks green to indicate normal on
FlashScan® systems.
Construction
Shell, door, and handle are molded of durable polycarbonate
material with a textured finish.
Specifications
Shipping Weight: 9.6 oz. (272.15 g)
Normal operating voltage: 24 VDC.
Maximum SLC loop voltage: 28.0 VDC.
Mãiimurn SLC tandbicurrent 375 1A.7
Mãiiñ,uiiiSLC alarm current: 5rnAJ
Temperature Range: 32°F to 120°F (0°C to 49°C)
Relative Humidity: 10% to 93% (noncondensing)
For use indoors in a dry location
The NBG-12LX
Addressable Manual Pull Station
Installation
The NBG-12LX will mount semi-flush into a single-gang, dou-
ble-gang, or standard 4" (10.16 cm) square electrical outlet
box, or will surface mount to the model SB-10 or SB-I/O sur-
face backbox. If the NBG-12LX is being semi-flush mounted,
then the optional trim ring (BG12TR) may be used. The
BG12TR is usually needed for semi-flush mounting with 4"
(10.16 cm) or double-gang boxes (not with single-gang boxes).
Operation
Pushing in, then pulling down on the handle causes it to latch
in the down/activated position. 0-ice latched, the word "ACTI-
VATED" (in bright yellow) appears at the top of the handle,
while a portion of the handle protrudes from the bottom of the
station. To reset the station, simply unlock the station with the
key and pull the door open. This action resets the handle; clos-
ing the door automatically resets the switch.
Each manual station, on command from the control panel,
sends data to the panel representing the state of the manual
switch. Two rotary decimal switches allow address settings
(1 - 159 on FlashScan® systems, 1 - 99 on CLIP systems).
Architectural/Engineering
Specifications
Manual Fire Alarm Stations shall be non-coded, with a key-
operated reset lock in order that they may be tested, and so
designed that after actual Emergency Operation, they cannot
be restored to normal except by use of a key. An operated sta-
tion shall automatically condition itself so as to be visually
detected as activated. Manual stations shall be constructed of
red-colored polycarbonate material with clearly visible operat-
ing instructions provided on the cover. The word FIRE shall
appear on the front of the stations in white letters, 1.00 inches
(2.54 cm) or larger. Stations shall be suitable for surface
mounting on matching backbox SB-iD or SB-I/O; or semi-flush
mounting on a standard single-gang, double-gang, or
DN-6726:D•4/13/2012— Page 1 012
FPC20I8-0329
4" (10. 16 cm) square electrical box, and shall be installed
within the limits defined by the Americans with Disabilities Act
(ADA) or per national/local requirements. Manual Stations
shall be Underwriters Laboratories listed.
Manual stations shall connect with two wires to one of the con-
trol panel SLC loops. The manual station shall, on command
from the control panel, send data to the panel representing the
state of the manual switch. Manual stations shall provide
address setting by use of rotary decimal switches.
The loop poll LED shall be clearly visible through the front of
the station. The LED shall flash while in the normal condition,
and stay steadily illuminated when in alarm.
Product Line Information
NBG-12LX: Dual-action addressable pull station. Includes key
locking feature. (Listed for Canadian and non-Canadian appli-
cations.)
NBG-12LXSP: Spanish/English labelled version.
NBG-12LXP: Portuguese labelled version.
SB-10: Surface backbox; metal.
SB-I/O: Surface backbox; plastic.
BG12TR: Optional trim ring.
17021: Keys, set of two.
NY-Plate: New York City trim plate.
Agency Listings and Approvals
In some cases, certain modules or applications may not be
listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.
ULIULC Listed: S692 (listed for Canadian and non-Cana-
dian applications).
MEA: 67-02-E.
CSFM: 7150-0028:0199.
FONY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030).
BSMI: C1313066760047.
U.S. Coast Guard.
Lloyd's Register.
FM Approved.
Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772;
6,632,108.
NOTIFIER® and FlashScan® are registered trademarks of Honeywell
International Inc.
02012 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
.: .- .-•-
I So 9001 This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
BYGINEERING &MNUFACTURINC All specifications are subject to change without notice.
QUALITY SYSTEMS Made in the U.S. A.
For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118.
www.notifier.com
Page 2 of 2— DN-6726:D • 4/13/2012
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7150-0028:0199 Page 1 of 1
CATEGORY: 7150-- FIRE ALARM PULL BOXES
LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653
Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309
Email: vladimir.kireyev@honeywell.com
DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB,
NBG-12-LO, NBG-12L0B, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP,
NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP,
NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull
boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and
NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listees name, model number, rating, and UL label.
APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units.
Models NBG-12WP, NBG-12LW, NBG-12W, NBG-I2LWP, NBG-12LAO, NBG-12L0,
NBG-12LAOB and NBG-12L0B are intended for outdoor use when installed with Models WBB,
SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details.
These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and
California amendments which the controls and operating mechanisms required to be
operable at no more than 51bs. force with one hand and shall not require tight grasping,
pinching, or twisting of the wrist.
*corrected 10-08-12 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2018 Listing Expires June 30, 2019
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division