Loading...
HomeMy WebLinkAbout1890 RUTHERFORD RD; ; FPC2016-0028; PermitJity of PERMIT REPORT Carlsbad Print Date: 02/09/2022 Permit No: FPC2016-0028 Job Address: 1890 RUTHERFORD RD, CARLSBAD, CA 92008-7344 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 12/07/2016 Valuation: $0.00 Lot #: Issued: 12/22/2016 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: GENOPTIX CTCE - INSTALLATION OF NEW FIRE ALARM Applicant: FPContractor: JMG SECURITY SYSTEMS JMG SECURITY SYSTEMS JUSTIN WALD 17150 NEWHOPE ST, # 109 17150 NEWHOPE ST, # STE 109 FOUNTAIN VALLEY, CA 92708-4273 FOUNTAIN VALLEY, CA 92708-4250 (714) 545-8862 (714) 545-8882 x326 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov F?c2o -0021 HIGHLIGHTED SET UL & FM Certificates of Compliance Cut Sheets and CSFM listings Genoptix CTCE 1890 Rutherford Road, Carlsbad, CA 92008 Revision #3: Tenant Improvement Additions Installation Company: ; VA 0'AGM SYSTEMS SECURITY Our service is your security. 17150 Newhope Street Fountain Valley, CA 92708 (714) 545-8882 U Appca'nt ib No: 26706.7-061 Service Center' No I Epire: 31-MAR-2017 CERTIFICATE OF COMPLIANCE THIS IS. TO CERT!FY that Itie Alarm Service ( rnpany indicated beloW i Include by Under ',r.' Laboratories Inc (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL'S Certificate Verification service This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate Listed ServiceFrom: LAKE FOREST, CA Alarm. Service .ComDaflv: (257057-004). ADVANCED PROTECTION INDUSTRIES INC, DBA. NATJONA1 MONITORING CENTER 25341 ..OMMERCENTRE 'DR LAKE FOREST CA 92630 Service Center: (2570574004) ADVANCED PROTECTION INDUSTRIES INC DRA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 The Alarm Señicè C&POMW isLiSted in the foflwi.flg Céjtific té Sér, ice Categories: File -Vol No. CCN Listing Categdy, .. ' 4 BP10307 - I CRZM , Naiôialndiistrial curity S8126 - I UUFX -jsignat and Fire Alarm Equipment Icesi (Protective Signaling Services) CébtIIrStation 7-HIS CERTIFICATE EXPIRES ON. 31.MAR 2017 V ••y .••• "LOOK EORicHE UL ALARM SYSTEM CERTIFICATE." S Certificate Oftompliance .. Project ID#30259W RR - .,. Issued July IT 2014 This is to certify that the central station service company indicated below is listed in the Approval Guide a publica t i o n o f F M Approvals, as eligible'to use the <FM> Approval mark in conjunction with protected, property installations ithas Placarded as being in compliancewiththe equipment service requirements of FM pprovaI Standard 3011 CENTRAL STATION APPROVED SERVICE FOR FIREALARMS AND PROTECTIVE EQUIPMENT SUPERVISION. CENTRAL STATION SERVICE - The installation testing and maintenance of signaling systems wherein fire alarm and related supervisory trouble and test signals are initiated at a subscribing property and monitored at a co n s t a n t l y a t t e n d e d central station where properly trained personnel take prescribed action on those signals 1nduding retran s m i s s i o n o f t h e signals, dispatch of runners to the protected property and appropriate record-keeping.-:FM Approved central station service is required to be provided under a single.contract This central station service company was examined and Approved in accordance with FM Approval Standa r d 3 0 1 1 ( E f f e c t i v e Date April 1999) for the following category CENTRAL STATION COMPANY (COMPLETE SERVICE) - Capable of providing all aspects of central station service as described above (X) CENTRAL STATION COMPANY (MONITORING ONLY) -Capable of providing only monitoring retransmission dispatch and record keeping aspects as described above All other aspects of central station s e r v i c e m u s t b e subcontractedto an:FM Approved CENTRAL STATION COMPANY (COMPLETE SERVICE) oran FM App r o v e d F l R E ALARM SERVICE —LOCAL COMPANY. FIRE ALARM SERVICE - LOCAL COMPANY -Capable of providing only installation testing maintenance and runner service aspects as described above All other aspects of central station service must be subco n t r a c t e d t o a n F M Approved CENTRAL STATION .COMPANY (COMPLETE SERVICE) or an FM Approved CENT R A L S T A T I O N COMPANY (MONITORING ONLY). ..Company:Service Center(s) Advanced Protection Industries Not Applicable dba National Monitoring Center .25341 CommercentreDrive . . . .. Lake Forest CA 92630 THIS CERTIFICATE EXPIRES ON 12/3112017 Continued Approval requires a satisfactory reexamination prior to the date shown above IM A D prova S® For more than 160 years FMApprovafs has partiwi i ed iwth business and industry to educe property losses . . Robert W Elliott Senior Engineering Specialist Member of the FM Global Group . ...FM Approvals . . 1151 'Boston -ProvidenceTurnpike . . . . . . Norwood, MA 02062.... . . . . .... . . . . ...................... DSILENT KNIGHT by Honeywell lntelliKnight® Model 5820XL Addressable Fire Alarm Control System The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or 5K devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL signal line circuit (SLC) supports multiple device types of the same protocol: SK (System Sensor) SD You cannot mix SD and SK SLC devices on a FACP. lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (5K protocol only) Addressable multi-criteria smoke detector (SK protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the lntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The IntelliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows®- based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved LJ1 — Ben 000005. Hens. contends E1 c c Smoke castles B L/DCircufts can beInputs or outputs Ji nnolodnnundeton PiWerlGeusoy Module (2 UnIts MaslSyOem( 3l5XL SIC Eoayndur lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel InteIIiKnight 5820XL Wnws Based Facility Addressable Fire Alarm System MunegemontSoftware SK (System Sensor) Protocol Devices Windows Based Up/Download S. rJ1 RS-232 ' Co=CS Automation Software t 5820XL SK-2/2UD Connection VisorAlarm lP Communicator 3F C Relays 5895XL on! Peerl/edute Sic-Ion SK45bnItor Sic-Iso SK-Control-8 Sic-Control 5200SR SK-Acclimate SK-Zone-S' AdelesunSo Addesseble Posit Isolator od&e000blo Supervised Sounder Muticntenio Zone 9999 leieons Monitor Module NotEcodon costol Blee "'I, InterneCe 5860 Detector Module fllolee Module W.chor May50 6K-Photo SK-Monitor-2 SK-Retaymon-2 SK-Photo-T Dualm.onfor AdnaGso5a Adoto5sAie Module Djdtolooitor Fhotoolontic WT—Relays Detector Slat, ws0101 Base Sane 5880 LED CofoDr& Input Module 4 IIlL;!! SK.Beam 8K410n-10 SK-Pull-DA 6K-Duct SK-5Thlmon SK-Relay-6 Sic-Zone -Relay SK4800m-T M&ossbIo SK-Pull-SA bdt0000tee MonItor ReSyConninnl Add-tue/Dc bdtr0000So I sto050acee Monitor ddnessalule un Module Module Intenfoce Relay Been oecsor Module Pull d-dion Detectot Module Module I I Use tho 5880 to control up 104 - 5883 Relay Interface Modules IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiation Circuits: .100 mA @ 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5"Wx 24.75"H x 3.9'D (36.8 W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ3IX (two required) S-BUS Accessories 5860/11 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the IntelliKnight system. 5820XL supports three 5815XL's. Each 5815XL can support 99 SK detectors and 99 SK modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6-Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm Hx152mm D) SD505-DTS-K Remote test switch. Used with 5D505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 SK Devices Data Sheet D SILENT This document Is not intended to be used for installation purposes. We try to keep our Made In America product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. .e.ii specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, NJorthford, CT 06472 PN 350210 Rev H2 by Honeywell Phone: (203)484-7161, Fax: (203)484-7118. www.siIentknight.com. © 2012 Honeywell International Inc. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight SD505-DUCTR D SILENT KNIGHT by Honeywell Analog/Addressable Devices with Hochiki (SD) Protocol SD Devices SD devices are intelligent analog/addressable devices for use with the following lntelliKnight addressable fire alarm control panels (FACPs): 5820XL, 5808 and 5700. SD detectors, modules, and accessories communicate to the FACP over the signaling line circuit loop (SLC loop) using a two wire connection. Shielded or twisted wire is not required. Up to 127 addressable SD devices can communicate with the FACP on a single SLC loop. Any combination of addressable SD devices and SD modules can be used on a single SLC loop. The assortment of SD detectors, modules, and accessories that are compatible with lntelliKnight addressable FACPs are described below. For detailed information on SD devices, see the device specification sheet. Detectors SD505-APS A photoelectric smoke detector. SD505-APS has an LED light source and silicon photo --- diode receiving element. The detector features automatic drift compensation for V. detector contamination and a simple calibration test procedure that can be run at the FACP or remotely using 5650/5651 Silent Knight Software Suite. SD505-APS (Base not included) SD505-AHS A fixed temperature heat detector that uses an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum airflow. SD-505-AHS offers a programmable trip [ point temperature from 135°F - 150°F - -' (57°C - 650C). This detector is well suited for environments where smoke detectors 5D505-AHS cannot be used because of the presence of (Base not included) steam or cooking fumes, such as in a kitchen. SD505-AIS An ionization smoke detector that has a sampling chamber and reference chamber for high stability and for a variety of applications where early warning of trouble super-heated or flaming combustibles is desired. Presence of visible smoke or invisible gases - greatly influences the current flow in 5D505-AlS the sampling chamber, changing the (Base not included) voltage ratio between the chambers. The difference is amplified inside the detector. When reaching a critical level, the detector triggers an alarm. SD505-DUCT A addressable duct smoke detector that detects smoke and products of combustion present in air moving through an HVAC duct. This duct detector is housed in a heavy duty metal housing with a preinstalled SD505-APS photoelectric smoke detector. SD505-DUCT has an air velocity rating from 300 feet per minute to 4,000 feet per minute. Order SD505-T2, 5D505-T5, or SD505-TI 0 air sampling tubes separately. SD505-DUCTR A duct smoke detector that detects smoke and products of combustion present in air moving through an HVAC duct. The SD505- DUCTR provides a fully programmable Form C contact. This duct detector is housed in a heavy duty metal housing with a preinstalled SD505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the detector communicates the condition to the FACP. The built-in relay module then turns off fans, blowers, and other devices. SD505- DUCTR has an air velocity rating from 300 feet per minute to 4,000 feet per minute Order SD505-T2, 5D505-15, or SD505-TIO air sampling tubes separately. Optional 5D505-DTS-2 remote test switch available. SD Devices Modules SD500-AIM 1.' — A dry contact input module that acts as an interface to contact devices, such as - waterflow switches and pull stations. The ° B. SD500-AIM supports Class B supervised iT wiring.This module monitors for alarm contact closures and open circuit wiring -' fault conditions. Mounts in a 4" square box. sD500-AIM - SD500-MIM A compact and light weight monitor module that acts as an interface to contact devices, such as waterflow, switches and pull stations. The SD500-MIM supports Class B supervised wiring. This module mounts in a single gang box. SD500-ARM A relay module that provides one relay with two Form C contacts rated at 2.OA @ 30 VDC or 0.6A @ 120 VAC. The SD500-ARM can control a wide variety of normally open or normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. SD500-ANM A notification module that lets you add notification circuits wherever they are needed on an FACP SLC loop. The SD500-ANM provides supervised monitoring of wiring to load devices such as bells, horns, and strobes. You can supply power to this module near the signaling appliance to reduce wire gauge requirements or supply power from a main power supply and control it separately by the individual notification modules. The SD500-ANM supports Class B and Class A wiring and all 16 notification patterns available on the FACP. SD500-SDM A two-wire interface module that allows an FACP to interface with and monitor two-wire conventional devices. This means. you can retrofit an existing building and use existing conventional devices, including two-wire smoke detectors and devices with dry contacts, such as pull stations and heat detectors. The SD500-SDM transmits the status condition (normal, open, or alarm) of one full zone of two-wire devices to the FACP. The SD500-SDM supports Class Band Class A wiring SD500-LIM A line isolator module that isolates a short circuit wiring fault on an SLC loop. When a short occurs on the SLC I loop, it is detected as a trouble but all of the SLC devices protected by a SD500-LIM will continue to operate. L..J . SD500-LIM SD500-LED An LED driver module that connects to the SLC loop and is capable of driving 80 LEDs. lntelliKnight FACP5 support up to 40 SD500-LEDs per SLC loop. Accessories SD500-PS/SD500-PSDA The SD500-PS is a single action pull station requiring only one motion to activate the station. The SD500-PSDA is a dual action pull station requiring two motions to activate the station. Both pull stations feature a rugged metal construction and mount in a single gang box. SD505-DTS-2 SD500-PS A remote test switch for use with the SD505-DUCTR that provides remote key operated test function and annunciation of detector alarm. SD505-6SB A 6" mounting base adds an audible output function to SD505- APS, SD505-AIS, and SD505-AHS. The SD505-6SB can be used as a single station, multi-station, or as a system sounder. SD505-6RB A 6" mounting base with one Form C relay contact. The SD505- 6RB lets you control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. Because this relay is addressable, the relay device can be located at any point on the SLC loop. S0505-61B A 6" mounting base with a built-in isolator for SD505-APS, SD505-AIS, and SD505- AHS detectors. When the SD505-61B is connected to the SLC loop, a short, open, or ground fault occurring on the SLC loop . is detected as a trouble but all SLC devices continue to operate. SD505-61B fits under SD505-6AB detector base (included).SD505-61B Isolator Base SD505-6AB A 6" mounting base is for use with SD505-APS, SD505-AIS, and SD505-AHS. SD505-4AB A 4" mounting base is for use with SD505APS, SD505-AIS, and SD505-AHS. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific KNIGHT applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, by Honeywell Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA PN 53624 Rev B2 © 2010 Honeywell International Inc. Before You Begin Installing 10 AC Input -------------- Route all low voltage wiring throu any -------------- I tl '110 phone Mauitairi 1/4 from under aluminum housing. spacir1getween: - 1'atter cables and Input wiring. All circuits, except battery cables arid AC, are ower limited. Maintain at least 1/4" spacing between power limited and I non-power limited circuits. Separate high and tow . • elack voltage circuits. Red -- - - - - - - - - - - - - - Fire alarm power-limited circuits are / - installed using types FPL, FPLR, FPLP - or permitted substitute cables, provided these power-limited cable i conductors extending beyond the I jacket are separated by a minimum of I 0.25 in. (6.35 mm) or by a nonconductive sleeve or nonconductive barrier from all other conductors. --------------------- Figure 3-1 Wire Routing Example 151209 3-5 sis nting Switch It grammi ng rts Intel/Knight 5820XL Installation Manual 3.5 Board Assembly Diagram On-board Annunciator To AC Figure 3-2 Model 5820XL Assembly Figure 3-2 shows the circuit boards, metal housing and annunciator that attach the 5820XL assembly to the cabinet. If you should need to remove the board assembly for repair, remove the four mounting nuts which hold the assembly in the cabinet. Then lift the entire assembly out of the cabinet. Do not attempt to remove the circuit boards from the metal bracket. 3-6 151209 Intel/Knight 5820XL Installation Manual 3.6 Calculating Current Draw and Standby Battery This section is for helping you determine the current draw and standby battery needs for your installation. 3.6.1 Current Draw Worksheet Requirements The following steps must be taken when determining 5820XL current draw and standby battery requirements. You will use the Current Draw Worksheet to determine current draw and standby battery requirements. Use Table 3-1 if installing SK SLC Devices and Table 3-2 if installing Hochiki SLC Devices. For the 5820XL, the worst case current draw is listed for the panel, addressable devices, and all SBUS expanders. Fill in the number of addressable devices and expanders that will be used in the system and compute the current draw requirements for alarm and standby. Record this information in the Current Draw Worksheet on Line A. Add up the current draw for all auxiliary devices and record in the table at Line B. Add up all notification appliance loads and record in the table at Line C. For notification appliances and auxiliary devices not mentioned in the manual, refer to the device manual for the current ratings. Make sure that the total alarm current you calculated, including current for the panel itself, does not exceed 6.0 A. This is the maximum alarm current for the 5820XL control panel. If the current is above 6.0 A you will need to use a notification power expander(s) such as the Silent Knight 5495 or the 5895XL intelligent power expander, to distribute the power loads so that the 5820XL or the power expanders do not exceed their power rating. Refer to the current draw worksheets provided with the 5495 or the 5895XL manuals so you do not exceed their power requirements. Complete the remaining instructions in the appropriate Current' Draw Worksheet for deter- mining battery size requirements. 3-6 151209 Before You Begin Installing 3.6.2 Current Draw Worksheet for SK SLC Devices Use Table 3-1 to determine current requirements during alarm/battery standby operation when SK SLC devices are installed. You can install up 99 SK detectors per loop (396 max per panel) and 99 SK modules per loop (396 max per panel). Copy this section if additional space is required. Table 3-1: Current Draw Worksheet for SK SLC Devices Device # of Devices Current per Device Standby Current Alarm Current For eh'dicithisfdrrnula: Thiscoltmiñ X ThiscbluñiflT Current per tilim1 of devices. Fire Panel (Current draw from battery) 1 Standby: 2l5 mA 21mA 385 mA Alarm: 385 sn\ Addressable SLC Detectors (99 max/loop & 396 max! panel)' - SK-Photo Standby/Alarm: 0.27 mA mA mA SK-Photo-T mA mA SK-Ion mA mA SK-Heat mA mA SK-Heat-HT mA mA SK-Beam (without integral test) SLC Standby/ Alarm: 2 m Aux. ' Standby: 2 mA mA Alarm: 8.5 mA mA SK-Beam-T 5(with integral test) SLC Standby! Alarm: 2 mA Aux. Pwr Standby: 2 mA mA - Alarm: 8.5 mA mA SK-Duct6 SLC Standb0.27 mA SK-Acclimate Standby/Alarm: 0.3 mA mA mA SK-Heat-ROR mA mA 151209 3-7 lntelliKnight 5820XL Installation Manual Device # of Devices Current per Device Standby Current Alarm Current Addressable SEC Modules SK-Control (99 max/loop & 396 max! panel)' SEC Standby! 0.375niA Alarm 0.375mA mA Aux Pwr Standby/ 1.7mA in.\ Alarm: 7mA mA SK-Monitor Standby/Alarm: 0.375 mA mA mA SK-Minimon mA mA SK-Pull-SA mA mA SK-Pull-DA SK-Monitor-2 Standby/Alarm: 0.75 mA mA mA SK-Mon10 Standby/Alarm: 3.5 mA mA mA SK-Relay-6 Standby/Alarm: 1.45 mA mA mA SK-Control-6 SEC Standby! 2.25 mA mA Alarm: 2.25 mA Aux Pwr Standby! 1.7 mA mA Alarm: 20 mA mA SK-Relay Standby/Alarm: 0.255 mA mA mA SK-Zone Aux Pwr Standby 12 mA mA Alarm 90 mA mA SEC Standby/ Alarm 0.27mA mA mA SK-Zone-6 Aux Standby 50 mA mA Alarm 270 mA mA SEC Standby/Alarm 2 mA III, mA SEC Acë B5O1BHT-2 Sounder Base (99 max/loop & 396 max! panel) Aux Pwr Standby: 1 mA mA Alarm: 15 mA mA SEC Alarm: 0.7 mA mA B224RB Relay Base Standby/Alarm: 0.5 mA iiiA mA RTS151/151 KEY Alarm: 7.5 mA mA RA100Z Alarm: lOmA mA SLC Isolator DevlcL SK-Iso (Isolator Module) (100 max/loop Standby/Alarm: 0.45 mA mA mA B224B1Isolator Base &400flX! Standby/Alarm: 0.5 mA mA mA Accessthies Modtlg 5815XL SEC Expander - (3 max.)-- Standby/Alarm: 55 mA mA f mA 5860 Remote Fire Alarm Annunciator (8 max) Standby 20 mA rrA Alarm: 25 mA mA 5824 Serial/Parallel Printer Interface Module 2 max " .' Standby/Alarm: 45 mA mA mA 5496 Intelligent Power Module (8 max.) Standby/Alarm: 10 mA 5895XL IntelliKnight Power Module Standby/Alarm: 10 mA mA mA 3-8 151209 B C D E F G H Before You Begin Installing Device # of Devices Current per Device Standby Current Alarm Current 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA - mA 5865-3 LED Annunciator Standby: 35 mA rnA Alarm: 145 mA mA 5880110 Module Standby: 35 mA in \ Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA rnA Alarm: 220 mA (22 mA per relay) mA Total System Current Ajxiliary Dc\ kesi Rekr to devices nianu'i F i i.nt ratir1. - — — Alarm/Standby: -- - mA - mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Notification-Appliahce Ciruit - Pefr to device manual for car, ntrating. Alarm: rn. mA Alarm: mA mA Alarm: mA -- - mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines E and F. Total standby All AH - Alarm sounding period in hours. (For example, 5 minutes =.0833 hours) H Multiply lines E and H. Total alarm All AH 4 Total ampere hours [Add lines G and I. required AH 1. Total does not include isolator devices or accessory bases. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. SK-Beam-T draws a maximum of 500mA from Auxiliary power only when the test feature is used. this should be considered when determining auxiliary power capacity but not calculated into current requirements for day to day operation. The SK-Duct housing contains a vacant mount for a SK-Relay (sold separately). Current draw for the SK-Relay is calculated by increasing the SK-Relay row of the calculation sheet by one for each SK-Relay used with a SK-Duct. 151209 3-9 lntelliKnight 5820XL Installation Manual 3.6.3 Current Draw Worksheet for Hochiki SLC Devices Use Table 3-2 to determine current requirements during alarm/battery standby operation when Hochiki SLC devices are installed. You can install up 127 Hochiki devices per loop (508 max per panel). Copy this section if additional space is required. Table 3-2: Current Draw Worksheet for Hochiki SLC Devices Device I ac # of Devices Current per Device Standby Current Alarm Current evice '[his column X I'hishii ('irn r if ih 'ofvices: lntelliKnight 5820XL Fire Panel (Current draw from battery) Standby: 215 mA 215 mA Alarm: 385 mA 385 mA Addressable SLC Device', SD500-AIM (508 max.)' Standby/Alarm: 0.55 mA mA mA SD5004vllM mA mA SD500-PS SD500ARM mA mA SD505-A}{S mA mA SD505-AIS mA SD505-APS mA mA SDSOO-ANM (508 max.)' Aux. Pwr Standby: 8 mA mA Alarm: 60 mA mA ________ SLC Standby! Alarm: .55 mA mA SDSOOSDM (508 max.)' LC Standby! Alarm: .55 mA mA mA Aux.Pwr Standby: 20 mA mA Alarm: 106 mA in\ MA SD500-LED (100 max.)' Aux. Pwr Standby 10 mA Alarm: 220 mA mA LED: 10 mA mA mA SLC Standby/ Alarm: 0.55 mA mA mA SLO Aesory 5D505-6RB (508 max.) Standby/Alram: .082 mA mA 5D505-6SB (508 max.) Aux. Pwr Standby: 1 mA mA Alarm: 32 mA mA ________ SLC Standby/ Alarm: .082 mA mA mA 5D505-ADHR SD505-DUCTR (508 max.) . Aux. Pwr Standby: 35 mA2 mA mA Alarm: 75 n2 SLC Al. / Standby/ Alarm: .082 mA mA mA 5D505-DTS SD505-DTS-K (508 max.) None, included with SD505-ADHR worst case. 5D505-ADH 5D505-DUCT (508 max.) None, included with detector current. SLCIsointOi Dvic 1024 (max) Standby/Alarm 0.092 mA mA mA SD505-6IB (509 max.) Aëcess6riéMddUlés 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mAl mA 5860 Remote Fire Alarm Annun. (8 max.) Stan 1 20 mA MA , I I Alarm: 25 mA I mA 3-10 151209 Before You Begin Installing A C D E F G H Device # of Devices Current per Device Standby Alarm Current Current 5824 Serial/Parallel Printer Interface (2 max.) Standby/Alarm: 45 mA mA mA 5895XL IntelliKnight Power Expander (8 max.) Standby/Alarm: 10 mA mA mA 5496 Intelligent Power Module Standby/Alarm: 10 mA mA mA 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 LED 110 Module Standby: 35 mA mu A Alarm: 200 mA amA 5883 Relay Interface (32 max.) Standby 0 mA III ,\ Alarm: 220 mA (22 mA per relay) mA Total System Current Auxiliary DTices3 Refer to devices manual for currëñt rating Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Alarm: mA mA Alarm mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2,5): H Multiply lines E and F. Total standby All AH Alarm sounding period in hours. (For example, 5 minutes =.0833 hours) H Multiply lines E and H. Total alarm AR AH 4 Total ampere hours Add lines G and I required AH Total does not include isolator devices or accessory bases. If using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC, 120 VAC or 240 VAC. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. 151209 3-11 lntelliKnight 5820XL installation Manual 3.6.4 Maximum Battery Standby Load Table 3-3 shows the maximum battery standby loadfor the 5820XL based on 24 and 60 hours of standby The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-1 for SK devices and Table 3 -2 for Hochiki devices) must be less than the number shown in Table 3 -3 for the battery size used and standby hours required * 33AHmax battery size for FM (Factory Mutual) installations.. Table 3-3: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm *Max Load for 60 hrs. Standby, 5 mins. Alarm 7 A 270 m 105 m 12 A 475 m 190 m 18 A 685 m 270 m 35 AR 1.3A 540 m * RequiredforNFPA 72 Auxiliary ProtectedFire Alarm systemsforFireAlarm Service (City Box) andRemote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter (DA CT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-3. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the required 24 hours standby power. Use Table 3-3 to calculate the correct battery amperes/hour rating needed for your installation. 3.7 Installation Tasks Overview This section provides a chart listing tasks that need to be performed when installing the Intel1iKnight 5820XL system. The chart is intended to be a handy way for you to make sure you have completed all necessary tasks. Unless noted, these tasks do not have to be performed in the order they are listed here. Important: Connect and address SLC devices before running JumpStart. Task See Sec. (for more info.) Main Panel Hardware Installation El Mount the control panel cabinet. 4.1 El Connect AC. 4.2 El Connect phone lines. 4.11 El Install 5815XL SLC expander modules (if needed). Required if more than 127 SLC devices are used. 4.6 El Install 5860 Remote Fire Alarm Annunciator modules if used. 4.5 El Install 5865 or LED Annunciator modules if used. 4.9 El Install 5880 LED 110 module if customized LED annunciation will be used. 4.8 El Install notification appliances. 4.13 El Install auxiliary power devices (if used). 4.13.5 El If using a printer, install the 5824 Serial/Parallel Printer Interface Module. 4.7 El Connect batteries (typically last step). 4.3 3-12 151209 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYI985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, lFP-1000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor Intelliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1 000 : Power Expander/Supply 5865-3/5965-4: LED Annunciator .5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LlM: Line Isolation Module SD505-6I13: Isolation Base SD-500 SDM: Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB: Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listees Installation Instruction Manual for details. NOTE: These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomeriy 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NP SERIES —NP 24-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied' their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspenicn 'stem. Gas Recombination. Multipurpose: Float r Cyclic u Usable in any orientation. Superior energy density. Lead calcium grids for extended li fe. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or term I nals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free, electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generatiofl The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Terminals '0 Z472, ri2 (:53 Ii15 1t1, r li t.43 sb * H Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any, Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any oientation, 6th no less of performance or fear of electrolyte 16~kage. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged ma sealed container. General Specifications j; 4ftt) 24 22.3 !_TII 20.4 14.4 12 79 MY W]s Th 9.5 T J 240 500 '- 1i_ 166 175 125 [TI' 9 E 2 2.45 Layout ff[7iO.a1tfn:,,a',,S1-- ~ RMENNI NP SERIES - NP 2412 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery frorh deep discharge Long Cycle-.Service Life Depending upon the average depth of discharge over a thousand discharge/chrge cycles can be expected Float Service Life The expected service life is five years in float standby applications Separators The use of the special separator material provides a very efficient insulation between plates preventing inter plate short circuits and prohibiting the shedding of active m aterials Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods yp to on year at normal ambient temperatures with no permnent loss of capacity. Operating Temperature Range The battenes can be used over 'a broad temperature range permitting considerable flexibility in system design and location Charge - 15°C to 50°C Discharge - 20°C to 60°C Storage - 20°C to 50°C (fully charged battery) ECFDISCHARGE CHARACTER1STIS I \ - 7 \ - J 261 IT) 4C(104' C(4619 C 0 - 12 15 1 0.2 CA - 25PC CONSTANT VLTA0E CUAI1GING - Ar2Or9 .25 12 7.50 Fk ---- -100 L\ TAGEI' - - 0 2 4 0 hO 3Z1*461 CH#AGINh3 TIME IF4O1JRS4 091 _KIM - -- .--- __ -I_-••ii -- - UI.BLItOI-CYGL1 Yuasa Battery Inc. Ir 2901 Montrose Ave Laureldale, PA 19605 IJ [J www.yuasabatteries.com Registered number 1548820 17' CAN.. I NP 24-12 February 2011 I Distributed by D SILENT KNIGHT by Honeywell SD500-AIM & SD500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the lntelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor 5D500-AIM supports Class A (Style 0) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the SD500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 502 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" D (12.4Wx 12.4 Hx2.5Dcm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5' W x 2.5" H x 0.7' D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing ........ ..... SD500-AIM SD500-MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559: 132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The S0500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatible FACPs Ordering Information 5820XL SD500-AIM Input Module 5820XL-EVS Addressable input module with ivory 5808 cover plate. 5700 -3:r SD500-MIM Input Module Addressable mini input module. D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all K IN specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350231 Rev. F © 2013 Honeywell International Inc CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0132 Page 1 of I CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYI985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mdsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac©honeywell.com DESIGN: Model SD500-ARM Relay Module and SD500-AIM, SD500-MIM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator i. Fire Engineering Division L....'IRE & CABLE Product Specification Issued: 2005 FIRE ALARM UNSHIELDED, RISER RATED PART NUMBER: FPLII20 DESCRIPTION: 2/18 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010' Insulated Conductor Diameter 0.060" Number of Conductors 2 Nom. Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter 0.170" Approximate Cable Weight (lbs .IKft.) 20 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20'C 6.43 Ohms/Kft. nom. Capacitance Between Conductors .9 1 KHz 35 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 'C to 60 'C Insulation Colors Red and Black Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) I8AWG TYPE FPLR DEVICE A B C C E F ZONE 0 12 3456 789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & cable. Any information contained herein shall not be disclosed to any party without Written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 Dazheng Industry District. Jinari, China.250 104 ARE& CABLE !lël:86-531-8257468 Fx56-531-8257466I 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1505:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: JINAN PAC CABLE & WIRE COMPANY248 Avenida Victoria, Unit A, San Clemente, CA 92672 Contact: ChristoperDerek McMullen (214) 701-2665 Email: derek.mcmullenlgmail.com DESIGN: Power Limited Fire-Protective Signaling Cable, Type FPL, FPLP and *FPLR. Refer to listee's data sheet for additional detailed product description and operational considerations. Insulation: PVC, SRPVC with minimum average thickness of 6 mils, minimum at any point at 5 mils; PVC compound Apex 910 with minimum average thickness of 6 mils, minimum at any point at 5 mils, maximum average thickness at 14 mils. *PVC compound Teknor Apex 96-A025A-115 with mm. average thickness 6 mils, mm. at any point 5 mils. Shield (Optional): Aluminum/polyester tape. Core Wrap (Optional): Polyester tape, 2 mils thick max. Jacket: PVC compound Teknor Apex 4128, PVC Compound Apex 910, and *PVC Compound 90-A033A-10 INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Type FPL, FPLP or *FPLR and UL label. APPROVAL: Listed as a power-limited fire protective signaling cable. *Rev. 11-14-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division