HomeMy WebLinkAbout3434 VIA MERCATO; ; FPC2019-0041; PermitPERMIT REPORT Q ty of Carlsbad Print Date: 02/09/2022 Job Address: 3434 VIA MERCATO, CARLSBAD, CA 92009-8485 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2230530500 Track #: Valuation: $4,462,970.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0041 Status: Closed - Finaled Fire Alarm Applied: 02/27/2019 Issued: 03/08/2019 DEV01024 Finaled Close Out: 02/24/2020 Inspector: Final Inspection: Project Title: LA COSTA TOWN SQUARE Description: 3RD SET OF REVISED PLANS FOR CINEPOLIS -NEW FIRE ALARM SYSTEM Applicant: WEST COAST FIRE AND INTEGRATION INC 3199 AIRPORT LOOP DR, # STE D COSTA MESA, CA 92626-3414 (714) 957-5750 FEE AMOUNT FIRE New Alarm System $1,265.00 FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Plan Review Per Hour - Office Hours $136.00 Total Fees: $1,673.00 Total Payments To Date: $1,673.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carisbadca.gov S SALES I 3199-D Airport Loop Drive Costa Mesa, CA. 92626 DESIGN • INSTALLATION Phone (714) 957-5750 Fax (714) 957-5749 www.westcoastfireinc.com SERVICE Lic.# CIO-989173 ACO# 7407 -Fec 2c°- oo4 West Coast Fire & Integration CA Fire Alarm • Access Control • Security • CCTV • Nurse Call • Voice/Data 0 4- Cinepolis 40 Carlsbad ( 3434 Via Mercato Carlsbad, CA 92009 Job# 19-010-03 Fire Alarm System Product Data n EI [1 df-60334:A4 • A1-100 (MS.9600LS(E)/Ms-9600UDLS(E)) (intelligent Addressable FACP) (with Optional 2nd LoopJ 8 FIreuTêALarms by Honeywell General Fire-Lite's MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Con- trol Panels) with an extensive list of powerful features. The combination of Fire-Lite's newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLSE FACP, offer the latest in fire protection tech- nology. LiteSpeedTM is a patented technology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the sys- tem polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Cir- cuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ioniza- tion, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. The MS-9600UDLS(E) includes a factory-installed DACT-UD2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Sta- tion via internet (optional IPDACT installed) or the public switched telephone network. Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download soft- ware and remote power expansion. FM APPROVED to UL ANSI 864. Controls And Indicators LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 12-key pad with full alphabet 4 cursor keys ENTER Special Features Easy mount chassis. 7 amp switching power supply. Large enclosure allows 18 amp-hour batteries DACT-UD2 plug-in communicator standard with MS-9600UDLS/E. Optional IPDACT Internet Protocol Digital Alarm Communicator/Transmitter Four Style Y (Class B) or two Style Z (Class A) NAC circuits. Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices. Automated control of ACC-25/50(ZS/T) audio speaker cir- cuits ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used. ANN-80(-W) Remote LCD Annunciator ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Printer Module ANN-RLY Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module (alarms only) The FLPS-7 power supply is a separate board while all other electronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabinet. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chas- sis with the electronics can be quickly installed with two bolts. DISABLED (yellow) BATTERY FAULT (yellow) 101 • GROUND FAULT (yellow) df-60334:A4 • 12/29/2009 - Page 1 of 6 Standard Features SLC LOOP SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 318 addressable devices per loop (159 detectors and 159 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG (3.1 mm2) using twisted, unshielded wire (see Wire Table on page 5). NOTIFICATION APPLIANCE CIRCUITS (NACS): (ir onboard NACs with additional NAC capability usin (output control modules (CMF-300 or CMF-300-6). The four CC1ass B NACs can be converted to two Class A NACs Ithe NACKEY (jncluded) Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 3.0 amps maximum per each NAC circuit Note: Maximum 24 VDC system power output is shared among all NAC circuits and 24 VDC special application aux- iliary power outputs. Total available output is 7.0 amps. ADVANCED FIRE TECHNOLOGY: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS/2 keyboard or PC (using the standard PS-TOOLS Windows® utility). Two-level user-programmable passwords. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. USER INTERFACE: Optional plug-in DACT-UD2 communicator (standard with MS-9600UDLS(E) with USB port for local upload/download. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules, ACS Series annunciators, LCD-80F remote annunciator, or ANN-80 Series Annunciators. ElA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. History file with 1,000-event capacity. EIA-485/ANN-BUS supporting up to 8 ANN Series Annunci- ators or 32 ACS Series annunciators. ElA-485 supporting up to 32 ACS annunciators. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Local piezo sounder. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTMF module (conventional reverse polarity/city box transmitter). Field-programming Features Off-line Programming: Create the entire program in your office using a Windows®-based software package (order pro- gramming kit PK-CD, containing PS-TOOLS, separately). Upload/download system programming locally to the MS-9600LS/E in less than one minute. Autoprogramming: Command the MS-9600L5(E) to program itself (takes less than 30 seconds). In the Auto-Program mode, the MS-9600LS(E) scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. Online Editing: While still providing fire protection, the MS-9600L5/E may be programmed from the front panel. Sim- ple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. English Label Library: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as 'FLR 3 HALLWAY:' or enter custom labels letter-by-letter. Use recall function to repeat previously used label. Program Check: Automatically catch common errors, such as control modules not linked to any zone or input point. Maintenance Alert The MS-9600LS(E) continuously monitors each smoke detec- tor and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more informa- tion. Automatic Test Operation The MS-9600LS(E) performs an automatic test of each detec- tor every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trou- ble. Terminal Blocks AC Power - TB1: 120 VAC, 60 Hz, 3.0 amps or 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery (lead acid only) - T132: Maximum charging circuit: Normal flat charge 27.6 VDC @ 1.0 amp. Maximum battery charger capacity: 26 AH. Minimum battery 12 AR. MS- 9600LS(E) cabinet holds maximum of two 18 AH batteries. For 26— 120 AH batteries, use the CHG-120F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG- 120F or CHG-75. Communication Loop - (standard) TB8: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, unshielded pair length. Maximum loop current: 400 mA (short circuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Supervised and power-limited. Notification Appliance Circuits - TB4: Power-limited cir- cuitry. Nominal operating voltage: 24 VDC. Current limit: fuse- less, electronic, power-limited circuitry. Maximum signaling current per circuit: 3.0 amps. End-of-Line Resistor: 4.71K ohm, 1/2 watt (P/N 71252 UL listed) for NACs. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. S S Page 2 of 6 - df-60334:A4 • 12/29/2009 S S Programmable and Trouble Output Relays - TB5: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB3, Terminals 1(+) & 2(-): Maximum ripple voltage: 10 rnVRMS. Up to 1.5 amps for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Nonresettable Power #1(24 VDC Nominal) -TB3, Termi- nals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 1.5 amps total DC current available from each output. Power- limited circuit. T133, Terminals 5 (+) & 6 (-): non-resettable power #2. Nonresettable Special Application Power #2 (24 VDC Nom- inal) - TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10mVRMS. Total DC current available from each output is up to 1.5 amps. Power-limited circuit, nonsupervised. EIA-485 (ACS/ANN) - TB6: Annunciator connector, program- mable for type ANN or ACS. Terminal 1 (+) and Terminal 2 (-). ElA-485 (TERM) - TB7: Terminal mode annunciator connec- tor, Terminal 1 (Out +), 2 (In +), 3 (Out -), 4 (In -). EIA-232 - TB8: PC/printer connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). Ordering Options MS-9600LS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board, and cabinet. MS-9600UDLS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes DACT-UD2, 80-character LCD display, single printed circuit board, and cabinet. DACT-UD2: Optional communicator for remote monitoring (standard with MS-9600UDLS). 4XTMF: Optional Transmitter Module provides a supervised output for local energy municipal box transmitter, alarm and trouble reverse polarity. It includes a disable switch and dis- able trouble. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (P/N: IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for addi- tional information. IPBRKT: Optional mounting bracket kit consisting of screws and battery shield with standoffs required when mounting the IPDACT in lower enclosure section of FACR IPSPLT: Optional Y-Adaptor which allows connection of both panel dialer outputs to one cable input to IPDACT (sold sepa- rately). ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PK-CD: Contains PS-TOOLS programming software for Win- dows®-based PC computer (cable not included). SLC-2L5: Optional expander module, enables second SLC loop. DP-9692: Optional dress panel for MS-9600LS(E). TR-CE: Optional Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two 25 AH batteries and one CHG-1 20F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds up to two 25 AH batteries. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 25 to 120 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. BAT Series: Batteries, see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer which uses tractor- fed paper. Compatible Addressable Devices All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. 1SD355: Addressable low-prof DèhotoeIectric smoke detectoL 5D355T: Addressable low-profile photoelectric smoke detector with thermal sensor. lH355:Fast-response,w-profehiIetector) H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that acti- vates at190° F (88°C). AD355: Low-profile, intelligent, 'Adapt" multi-sensor detector; B350LP base included. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. I D350PL.-Photoblectric low-f low duct smoke detector.) D350RPL: Photoelectric low-flow duct smoke detector with relay option. IMMF-300: Addressable Monitor Module for one zone of imally-open dry-contact initiating devices. Mounts in standard) (4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for etheraSty ((CIassB)prStyieo(ClassA)jpp) MDF 300 Dual Monitor Module. Same asMMF excep!jfj MMF-301: Miniature version of MMF-300. Excludes LED and $Style D option. Connects with wire pigtails. May mount in' (device backbox.1 MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. ICMF-300: Addressable Control Module for one Style W ((Class B/A) zone of supervised polarized Notification Appli- rances. Mounts directly to a 4.0" (10.16 cm.) electrical box.S INotification Appliance Circuit option requires external 24 VD ippower notification apphance F300 Addressable relay module containing two ISO.ecF isets of Form-C contacts, which operate as a DPDT switch.l Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. rnod (uie,rnounted inside.) 1300: This module isolates the SLC loop from short circuit con- ditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. df-60334:A4 • 12/29/2009 - Page 3 of 6 E!A-485 24 VOC INTERFACE (4-data wires, 2-power wire tri o OCO Audio Control for ACC.25/50(ZSIT) Audio-Command-Center DACT-UD2 for Central Station reporting DAC (see photo detail below) LCD-80F Up to 6,000 ft. (1825.8 m) between each LCD-80F in the EIA-485 loop, and between each LCD-80F and the FACP EIA -485 ACS/ANN-BUS ANNUNCIATORS (2-data wires, 2-power wires) ANN-80 EIA-232 I INTERFACE 4-J PRINTER Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTMF) Ipur 4XTMF Reverse Polarity Module 11111111 B FORM-C, 5-AMP RELAYS (optional, order ACM-SRF) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES IJA I-UUL + , ~uuuuI ,e, IPOACT Internet Protocol DACT I-.. SMOKE DETECTORS SD355, SD355T, CP355 HEAT DETECTORS H355, H355R DUCT DETECTORS D350PL, D35ORPL dO 5) MONITOR MMF-300, MDF-300, MMF-302, CMF-300, CRF-300, 1300 I'll MINI MOMTOR MMF-301 ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302-6, CMF-300-6, CRF-300-6 INTELLIGENT BEAM DETECTORS -- - - - BEAM355, -. BEAM355S S 11 PULL STATION BC-i 2LX Page 4 of 6 - df-60334:A4 • 12/29/2009 C MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-617. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-617. Compatible Annunciators N80: Remote LCD annunciator tKa_-tmiin_iZ_stIli~6fo_P mation displayed on the FACP's LCD display. Recommended wire type is unshielded. (Basic model isred; order -Wversiop' ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points (see DF-6024 1). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays (see DF- 5243 1). ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a Serial or Parallel printer (see DF-52429). ANN-I/O: I/O Driver Module provides connections to a user supplied graphic annunciator (see DF-52430). ACS-LED Zone Series: LED-type fire annunciators capable of . providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. ACS-LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. TERM MODE LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 LCD- 80F annunciators may be connected to the ElA-485 terminal mode serial interface on the MS-9600L5(E) motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9600LS(E), see the following data sheets (docu- ment numbers) ACM-8RF (DF-5 1555), ACS/ACM Series (OF- 52378), LOM Series (DF-5 1384), LCD-80F (OF-52185). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. df-60334:A4 • 12/29/2009 - Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Cabinet Specifications S Intelligent Signalling Line Circuits ............. .expandable t02 Intelligent detectors ..........................................159 per loop Addressable monitor/control modules ..............159 per loop Programmable software zones.........................................99 ANN-BUS devices ..............................................................8 ACS Annunciators .............................................................32 LCD Annunciators ............................................................32 Electrical Specifications Primary input power: 120 VAC, 50/60 Hz, 3.0 A. 240 VAC, 50 Hz, 1.5 A. Battery: 27.6 VDC @ 1.0 A (max). Maximum battery charger capacity: 26 AH. Minimum battery: 12 AH. MS-9600LS cabinet holds maximum of two 18 AH batteries. Communication Loop: 24 VDC nominal, supervised and power-limited. Notification Appliance Circuits: terminal block provides con- nections for four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 3.0 A. End-of-Line Resistor: 4.7 K ohms, ½ watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Supervised and power-limited. Refer to panel documentation and Fire-Lite Device Compat- ibility Document for listed compatible devices. Two Programmable Form-C Relays and One Fixed Trouble Form-C Relay: Contact rating: 2.0 A @ 30 VDC (resistive) 0.5 A @ 30 VAC (resistive). Four-wire Resettable Special Application Power (24 VDC nominal): Up to 1.5 A for powering four-wire smoke detec- tors. Power-Limited, nonsupervised. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Nonresettable Special Application Power #1 (24VDC nomi- nal) TB3, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS Total DC current available from each output is up to 1.5 A. Power-limited, nonsupervised. Nonresettable Special Application Power #2 (24VDC nomi- nal) TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10 mVRMS Total DC current available from each output is up to 1.5 A. Power-limited, nonsupervised. NOTE: Although each Special Application power output can deliver 1.5 A individually, the total power output from these circuits cannot exceed 1.5A in standby. The total Alarm output for all Spe- cia/Application power and NAC circuits cannot exceed 7 A. Door: 19.26° (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.67 (1.70 cm.) deep. Backbox: 19.00 (48.26 cm.) high x 16.65 (42.29 cm.) wide x 5.21" (13.23 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: 20.00" (50.80 cm) high, 22.5" (57.15 cm) wide, 8.5" (21.59 cm) deep. Weight: 27.3 lbs (12.38 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27"C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the MS-9600L5(E) and MS-9600UDLS(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. ULC: S624 (MS-9600LSC only; see DF-60438) FM APPROVED: to UL ANSI 864 CSFM:7i79:0075i7) MEA: 87-08-E NFPA Standards The MS-9600L5(E) and MS-9600UDLS(E) control panels comply with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Requires 4XTMF where DACT-UD2 is not accepted.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT (Other Technologies-PSDN) For use with IPDACT. LiteSpeed"° is a trademark; and FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 900tS document is not intended to be used for installation purposes.____________ e try to keep our product information up-to-date and accurate. cannot cover all specific applications or anticipate all requirements. QUALITY S V STE M11 specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Page 6 of 6 - df-60334:A4 • 12/29/2009 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0217 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Models MS-9600LS and MS-9600UDLS addressable fire alarm control units. Suitable for local protective, remote, auxiliary, and central station signaling when used with appropriate optional modules and additional separate listed equipment. The panels provide one signaling line circuit for connection of up to 318 total addressable devices (159 detectors and 159 modules); two Class A or four Class B notification appliance circuits; three form C relays are provided that are default programmed for alarm, trouble, and supervisory relay outputs. The MS-9600UDLS come with the DACT-UD2 factory installed. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-9600L5, MS-9600UDLS Control Unit SLC-2LS Loop Card DACT-UD2 Digital Alarm Communicator Transmitter Modules 4XTMF Transmitter Module LDM-32F Lamp driver Module ACM-8RF Control Relay Module ANN-RLY Remote Relay ANN-80 , ANN-LED, LCD-80F Remote Annunciator . ACM-I6ATF, ACM-32AF Remote Annunciator AEM-1 6ATF, AEM-32AF Remote Annunciator ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207) RATING: 120 VAC, 50/60 Hz, 3.0 amps INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and FM label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Also suitable for high-rise applications for use with Model ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207). *Models MS-9600L5 and MS-9600UDLS panels are also suitable for high-rise application for use with Model ECC-50/1 00 emergency voice evacuation panel (CSFM # 6911-0075:0226). Refer to manufacturer's Installation Manual for details. These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition and meet the requirements of *Rev. 01-20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0075:0217 Page 2of2 UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. Combined with 7170-0075:220 *Rev. 01-20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division df-52417:c • B-90 ANN-80 S 80-Character LCD Serial Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC. Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4° square electrical box. Semi-flush mount to single, double, or 4° square electrical box. Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-80s can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble (a FlreuTe®Atarms by Honeywell S Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. df-52417:c • 05/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm 2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. S Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. S WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power win . Ing are supervised and power-limited. TB1 4321 ANN-BUS Device -+AB a MS-9050UD T133_________________ 12345678 FACP Wiring to ANN-BUS Device ORDERING OPTIONS: ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80K1T-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEEIING a MANNACTUMNS All soecifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - df-5241 7:c • 05/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120-- ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Model ANN-80 and *ANN..80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. S Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division i S S 0 S S S ECC-50/1 OOC Emergency Command Center General Fire-lite's ECC-50/1 OOC is a multipurpose emergency voice evacuation panel for fire applications, mass notification appli- cations, or both. The Primary Operating Consoles (POC's)delivers 50 or 100 watts of audio power for distribution to up to eight speaker circuits (i.e. zones). The ECC-50/100C comes standard with a single speaker circuit and a built-in 25Vrms, 50 watt amplifier. A secondary 50 watt amplifier (ECC-50W-25/70V) can be added for single speaker circuit backup or to increase system capacity to two speaker circuits and an additional 50 watts of audio power. An optional ECC- CE6 module added to the ECC-50/100C will upgrade the sys- tem to a maximum of eight speaker circuit outputs. All speaker output circuits can be wired in either Class B or Class A config- uration. The ECC-50/I00C has fourteen field programmable messages (up to 60 seconds each), built-in field configurable pre- and post-announce tone generators and a fully super- vised Notification Appliance Circuit (NAC) with 2.0 amps of synchronized NAC power. The ECC-50/I00C includes three built-in Form-C relay contacts, (AC power, trouble and MNS active) a NAC follower input for triggering the on board NAC circuit and 500mA special application power. A built-in power supply with switch mode technology delivers operational power to the panel and on board battery charger supports charging up to 26AH batteries (ECC cabinet holds up to 18AH batteries). For fire protection applications, the ECC-50/1 OOC is an adjunct (slave) to most ULC listed FACPs or as a stand-alone unit for non-fire applications. For seamless integration between fire and mass notification, the ECC-50/100C can be activated by the MS-9600LSC(-FR) and MS-9200UDLSC(-FR) when con- nected to the serial communication bus. Activation of the ECC- 50/1 OOC via other FACP's uses the eight on board Command Input Circuits (CMD's). Two of the eight CMD circuits (CMD 1 & CMD 2) can be individually field programmed for activation by an FACP Notification Appliance Circuit reverse polarity and all eight can be activated by a contact closure. In addition, the ECC-50/100C can be activated from a building's Private Branch Exchange (PBX) with the integral night ring feature. All ECC-50/100C programming is done by using a simple, built-in programming utility accessed from any laptop. For added flexibility, the ECC-50/1 OOC supports both 25Vrms and 70.7Vrms speaker output operation. By adding a 70V trans- former conversion module (ECC-XRM-70V) or an additional 70.7 volt secondary amplifier (ECC-50W-25/70V) the system supports 70.7 volt speaker devices. To add more control and increase system capacity, any com- bination of up to eight external remote consoles (including the ECC-LOC). TYPICAL APPLICATIONS The ECC-50/100C is used in applications that require single- channel voice evacuation for buildings with an occupancy greater than 1,000 occupants. Features Modular design for system flexibility and easy expansion Removable terminal blocks for ease of servicing and mod- ule replacement Canadian DF-6081 5:B 8 FureuTeALarms by Honeywell 50 watts of 25V audio power (expandable to 100 watts) RMS 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, or Wheelock pro- tocols Optional 70.7V RMS conversion transformer available for the primary amplifier. (Note that speaker wiring continues to be supervised in standby, alarm and when background music is playing with this optional transformer installed) Eight Command Input Circuits to activate messages I to 8: - CMDI and CMD2 are field selectable to be activated from 12 or 24 VDC Notification Appliance Circuits (reverse polarity) or contact closures - CMD3-CMD8 are activated by contact closures Speaker Circuits - Single Class B or Class A speaker Circuit - Two Class B or Class A speaker circuits (with optional ECC-50W-25/70V Audio Amplifier installed) - Eight Class B or Class A speaker circuits (with optional ECC-50W-25/70V and ECC-CE6 installed) ECC-50/100C can be controlled by an FACP via the ANN/ ACS (EIA-485) link. Compatible FACPs include the MS- 9600(UD)LS and MS-9200UDLS Certified for seismic applications when used with the appro- priate seismic mounting kit Integral supervised microphone Microphone time-out feature which reverts back to prere- corded message if emergency page exceeds the pro- grammed time 14 recorded messages Field-selectable message and custom message recording capability using the local microphone, a USB port, or an external audio input External Audio Input can be used for background music DF-6081 5:B • 7/28/2015 - Page 1 of 6 Up to 60 second message duration for all messages Integral tone generators field selectable for multiple tone types Powered by integral AC power supply or batteries during AC fail Programmable delay of immediate, 2 hours or 6 hours reporting of AC Loss Piezo sounder for local trouble 100 event history log Three Form-C relays: - AC Power Loss Relay - TB1 - System Trouble Relay - T132 - MNS Active - T133 500mA (0.5A) Special Application (auxiliary power) output for addressable modules when interfaced with compatible addressable FACPs and End-of-Line power supervision relays System Status LEDs (refer to "Controls and Indicators" on product manual LS10001-000FL-E) Integral Dress Panel Optional TR-CE semi-flush trim ring Any combination of up to eight (8) external remote con- soles: - Optional ECC-LOC Local operator console (includes cab- inet). See DF-60814. Optional Internal Expansion Modules ECC-CE6: Circuit Expander Module provides connections for up to six Class A or Class B speaker circuits. Circuits are con- figured through the web-based programming utility. ECC-50W-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100C power output to 100 watts or can also be used as a backup amplifier. ECC-50W-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/1 OOC power output to 100 watts or can also be used as a backup amplifier. ECC-XRM-70V: 70V Transformer Conversion Module. Con- verts the ECC-50/100C primary amplifier to a 70V output. This transformer mounts directly to the ECC-50/100C main control board by two metal brackets. ECC-RTZM: Remote Telephone Zone Module. Allows for secure access to the ECC via cell phone or remote telephone means; not ULC listed. AU. InN5 STSTEM$ I ACTIVE411111, 71RESYSTEI cwg OVERRIDE OKML SPEAKER svis SPEAKER ZEI5 p INS CDO ZONE 1 SPEAKER SPEAKER ZONE 14 2015 2 SPEAKER ZONE 3 SPEAKER ZONE 15 m ONTOPAGE Ca 0 SPEAKER ZONE 4 SPEAKER ZCRE 16 MPCROS'I4t*IE TROUBLE SPEAKER SPEAKER ZONE I? (=) MESSAGE I ZONE S SPEAKER ZONE 6 SPEAKER ZEI5 (=) MESSAGES 1-7110 SPEAKER ZONE 1 SPEAKER ZONE 19 MESSAGES SPEAKER ZONE S SPEAKER ZONE 20 MESSAGES SPEAKER ZONE S SPEAKER ZCSE 21 () MESSAGES SPEAKER ZONE IS SPEAKER ZONE 22 MESSAGES SPEAKER ZONE Ii - SPEAKER 2011E23 (=) MESSAGE 7 SPEAKE ZONE $2 R M24 0 SPEAKER ZE24 D I MESSAGE S GIAGNOSTIC 0 ERGEaLS 55.6156 Lj CO'$OLI 1I$T REMOTE AMPS -....-- AC po.us 0 MASS CONSOLE f> 01ST AMP I GROUND 1*111.1 oil. LOG 1 GIST. AMP 1> CHARGER 151110 0 OIST AMP 3 BATTSRYFAIJ&T 0 0 NPU 1 > GIST AMP QATAIMSFAI$.T 0150 AIAK N 1> NEC FelLs )' NPU 3 I> DINT AIAK N SINE ACTIVE 0 NM I GIST AMP > SYSTEM MULE RM2 GIST. AMPS > 511010 0565 FAULT 0 ER 3 Control and Indicators PUSH BUTTON CONTROLS All Call • Message Select 1-14 MNS Control • Diagnostic Select System Control • Trouble Silence Speaker Select 1-24 • Console Lamp Test S Page 2 of 6— Canadian DF-608153 7/28/2015 S 9 Ago DER 7LY C Circuit Speaker Circuits TB1 9 TB20 & TB21 a K RL L! LL 08 EMERGENCY COMMAND CENTER Flre.neIarms by Honeywell external battery charger-J7 0 CHG-120F charger ECC50W25/70V ECC-CE6 circuit expander optional amplifier Internal options ------ uF Jur*1!i ft ECCLOC local operator console TB4 TBI2 TB22 ECC-501100C Emergency Command Center (Possible Configurations) Canadian DF-60815:B 7/28/2015 - Page 3 of 6 LED Status Indicators (visible with door closed) Fire System Active (green) LOC/RM 1-8 Active (green) MNS Control (green) Main Console Fault (yellow) System Control (green) AC Power (green) System in Use (green) Ground Fault (yellow) Speaker Zone 1-24 Active Charger Fault (yellow) (green) Speaker Zone 1-24 Fault (yellow) Battery Fault (yellow) OK to Page (green) Data Bus Fault (yellow) Microphone Trouble (yellow) NAC Fault (yellow) Message 1-8 Active (red) NAC Active (green) Message 1-8 Fault (yellow) System Trouble (yellow) Remote Amplifier 1-8 Fault (yellow) Audio Riser Fault (yellow) LOCIRM 1-8 Fault (yellow) LED Indicators (visible with door and dress panel open) Speaker Volume Control Fault (yellow). Option Card Fault (yellow). Amplifier Over Current Fault (yellow). Product Line Information ECC-501100C: (Primary Operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacuation system, integral microphone, built in tone generator and 14 recordable messages. ECC-CE6: Speaker Circuit/Zone Expander Module. ECC-50W-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100C power output to 100 watts or can also be used as a backup amplifier. ECC-50W-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100C power output to 100 watts or can also be used as a backup amplifier. ECC-XRM-70V: 70V Transformer Conversion Module. Con- verts the ECC-50/1 OOC primary amplifier to a 70V output. This transformer mounts directly to the ECC-50/100C main control board by two metal brackets. ECC-RTZM: Remote Telephone Zone Module. Allows for secure access to the ECC via cell phone or remote telephone means; not ULC listed. ECC-LOC: Local Operator Console (Complete user interface), Please refer to the data sheet DF-60814 for more information. SEISKIT-COMMENC: Seismic kit for the ECC-50/100C. Includes battery bracket for two 12 AH or 18 AH batteries. MMF-301A: Addressable Mini-Monitor Module. 1300A: SLC Line Isolation Module. TR-CE: Optional Trim Ring. THUMBLTCH: Optional Thumb Latch. (Non ULC-Listed). CHG-120F: 25-120 ampere-hours (AH) External Battery Charger. ECC-MICROPHONE: Replacement Microphone only. BAT-1270: Battery,12 volt,7.0 AH (Two required). BAT-12120: Battery, 12 volt, 12.0 AH (Two required). BAT-12180: Battery,12 volt, 18.0 AH (Two required). Wiring Requirements See product manual, part number LS10001-000FL-E for detailed wiring requirements. Total System Capacity: (ECC-50/1 OOC only) Total Built-in Audio Power: 50 Watts. Total Expandable Audio Power: 100 Watts. Total Built-in Speaker Circuits: 2. Total Expandable Speaker Circuits: 8. Audio Message Max Time Duration: 60 seconds. External Audio Input: 1. Electrical Specifications PRIMARY (A C) POWER (TB 15) ECC-50/I00C: 120 VAC, 60 Hz, 3.5 amps (HOT, NEU). Wire size: minimum #14 AWG (2. 00mm2) with 600 V insulation. SECONDARY POWER (BATTERY) CHARGING CIR- CUIT (J7) Supports lead-acid batteries only. Float charge voltage at 27.3V Maximum charge current: 1.0 Amp Maximum battery charge capability: 2.8 Amps, 26AH (ECC cabinet holds max. 18AH battery). Minimum Battery size: 12 Amp Hour. AC LOSS RELAY CONTACT RATING (TB3) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). FORM C - TROUBLE RELAY CONTACT RATING (TB2) 2.0 amps @ 30 VDC (resistive), 0.5 amp @ 30 VAC (resistive). MNS ACTIVE RELAY CONTACT RATING (TBI) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). NOTIFICATION APPLIANCE CIRCUIT (NAC) OUTPUT RATING (TB 19) One (1) Class B or Class A circuit. Power-limited circuitry, (Class 2) supervised. Nominal operating voltage: 24 VDC. Maximum signaling current for special application power: 2.OA. Maximum signaling current for regulated power: 200mA. Maximum wiring impedance: 1). Current limit: fuse-less, electronic, power-limited. End-Of-Line Resistor: 4.7 KQ, %watt, (P/N 71252) required for Class B operation. Refer to the Device Compatibility Document 15384 for listed compatible devices. NAC FOLLOWER OUTPUT REMOTE SYNC (TBI8) Connections for FACP NAC synchronization trigger signal. Trigger input voltage: 9 to 32 VDC, 24 VDC rated. Input current draw in Alarm condition: 10 mA at rated volt- age. C S Page 4 of 6— Canadian DF-60815:B • 7/28/2015 S S S SPECIAL APPLICATION POWER (AUX. POWER) (TB 17) 500mA@24VDC Used for powering addressable modules and associated End-of-Line power supervision relays Power-limited circuitry. Refer to the Device Compatibility Doc- ument 15384 for a list of compatible devices. SPEAKER VOLUME CONTROL OVERRIDE (TB23) Class B or Class A circuit Special application power Power-limited circuitry, supervised Nominal operating voltage: 24 VDC Maximum signaling current: 0.25 amps Current limit: fuse-less, electronic, power-limited End-Of-Line Resistor: 4.7 K1, 1/2 watt, (P/N 71252) required for Class B operation Speaker Circuits Primary Speaker Circuit (TB20) Secondary Speaker Circuit (TB21) (with optional amplifier only) - Circuit can be wired Class B or Class A - Power-limited circuitry - Normal Operating Voltage: 25 VRMS @ 2 amps max and maximum Load Impedance of 12.50 (70.7 VRMS @ 700 mA max. with maximum load Impedance of 100Q opera- tion possible by plugging optional ECC-XRM-70V conver- sion transformer into J12 of the main control board) - Output Power: 50 watts (10 watts when background music is employed) - Frequency Range: 400Hz - 4,0001-1z - Maximum total capacitance for each speaker circuit: 250 IJF - End-of-Line Resistor required for Class B circuit: 15 Kg), I watt (P/N: ELR-15K) Command Input Circuits (alarm polari- ties shown) CMD1 - TB4 Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices down stream. CMD2 - TB5 Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices downstream. CMD3 - TB6 Terminals 1(i-) & 2(-) are input terminals for con- tact closure only. CMD4 - T136 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD5 - TB7 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD6 - TB7 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD7 - T138 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD8 - TB8 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. Power-limited and supervised circuitry Normal Operating Voltage Range: 10.5 VDC - 29 VDC; (Maximum Voltage: 29 VDC) NAC Reverse Polarity Current (requires End-of-Line Resis- tor from NAC): 1.6 mA maximum Contact Closure Operation Current (requires 4.71<, 1/2 watt End-of-Line Resistor P/N 27072): 6.6 mA maximum Maximum Wiring Impedance CMD1 - CMD8 (Contact Clo- sure Operation): 2001 NOTE: When the system is programmed for Mass Notification, CMD land CMD2 will be programmed for Reverse Polarity only. See manual P/N: LSI000I-000FL-E for more details. MAXIMUM INPUT IMPEDANCE: CMD1 & CMD2 (Reverse Polarity Operation): 20KQ CMD1 - CMD8 (Contact Closure Operation): 4.75Kc NIGHT RING INPUT - T19I6, TERMINALS I (+) & 2 (-) Contact closure input Isolated, non-supervised Operation current: 3.8 mA, maximum Maximum wiring impedance: 30KQ Minimum isolation withstand voltage: 1500 VRMS EXTERNAL OPERATOR INTERFACE POWER OUTPUT (TB24) Non-resettable power for external operator interlace com- ponents Power-limited circuitry, non-supervised Nominal operating voltage: 24 VDC Maximum output current: 0.80 amps Current limit: fuse-less, electronic, power-limited circuit EXTERNAL DATA BUS (EIA-485) (TBI2) Data connections for external operator interface components Redundant transceiver circuitry for Class A operability Power-limited circuitry, supervised Maximum wiring impedance: 13.212. FACP DATA BUS (EIA-485) (TBI3) Dedicated connection to FACP serial bus Output terminals: pass-through to other system components. Isolated, supervised Minimum isolation withstand voltage: 1500 VRMS Maximum wiring impedance: 401 (ANN-BUS), 26L (ACS-BUS) External Audio Riser (TB22) Class B or Class A audio connections to external operator interlace components Power-limited circuitry, supervised Audio signal level: 3.85 V, maximum Frequency range: 400 Hz -4 KHz RMS ELECTRICAL SPECIFICATIONS DISPLAY BOARD EXTERNAL AUDIO INPUT (TB5) Input Impedance: 8.51<92 nominal @1KHZ Input Voltage: 700 mVrms maximum Input Current: 0.1 mA maximum @ 700 mV NOTE: Some laptops/personal computers only provide an audio output for headphones. It may be necessary to adjust the head- phone output level for proper recording of voice messages. ECC-CE6 Circuit Expander Module Specifications Power-limited circuitry Canadian DF-60815:B • 7/28/2015 - Page 5 of 6 Up to six (6) circuits on the ECC-CE6 can be wired as Class B or Class A) Normal Operating Voltage for Speaker Circuits: 25 VRMS @2.0 amps max. (Maximum Load Impedance of 12.59) 70.0 VRMS @ 700 mA max. with maximum Load Imped- ance of 10092 operation possible for the primary circuit by plugging in an optional ECC-XRM-70V conversion trans- former into J12 of the main control board. The same opera- tion is possible for the optional 50W amplifier by selecting the ECC-50W-70V model Speaker circuit wiring is supervised during standby, back- ground music, and alarm Output Power: 50 watts total; Frequency Range: 400Hz - 4,000Hz Maximum total capacitance: 250 pF. (Note that the total capacitance for the speaker outputs must not exceed the maximum of 250 ijF) End-of-Line Resistor required for Class B speaker circuit: 15 KQ, 1 watt (PIN: ELR-15K) TB13 on the main control board: ACS/ANN (ElA-485) electrically isolated link to FACP provides programmed speaker control Cabinet Specifications Backbox: 19.0"(48.26 cm) high x 16.65(42.29 cm) wide x 5.20(13.23 cm) deep. Door: 19.26" (48.92 cm) high x 16.82"(42,73 cm) wide x 0.12"(0.30 cm) deep. Trim Ring (TR-CE): 22.00" (55.88 cm) high x 19.65" (49.91 cm) wide. Shipping Specifications Base Unit Weight: 27.85 lbs (12.63 kg). Temperature and Humidity ranges This system meets ULC requirements for operation at 0-49° Cl 32-120° F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27° C160-80° F. Agency Listings and Approvals The listings and approvals below apply to the basic ECC-501 100 control panel. In some cases, certain modules may not be listed by certain approval agencies or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed S2424 CSFM: 7300-0075:0226. NYC Fire Dept. Certificate of Approval: #6152 FM Approved. Standards and Codes The ECC-50/100C complies with the following ULC Standards, International Building Codes, and with NFPA 72 Fire Alarm system requirements. CAN/ULC-5572. IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized, use of this document is strictly prohibited. S This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. i Ml We cannot cover all specific applications or anticipate all requirements. 15111111YEEIIIIII &MANIMCIUIUNG All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6— DF-60815:B • 7/28/2015 111 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6911-0075:0226 Page 1 of 1 CATEGORY: 6911 --VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models ECC-501100 and ECC-50/100E. These are 50-watt audio emergency voice evacuation panels expandable to 100-watt for fire applications, mass notification applications, or both. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: *ECCLOC: Local Operator Console ECC-MCB; Main Control Board ECC-DKVCM; Display Board ECC-50W-25V; Amplifier Module 25 VRMS ECC-50W-70V; Amplifier Module 70 VRMS ECC-CE6; Speaker Circuit Expander Module ECC-XRM-70V; Transformer Module 70.7 VRMS RATING: Primary Operating: 120 V, 60 Hz, 3.5 A or 240 V, 50 Hz, 2 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as voice communication systems for use with separately listed compatible fire alarm control units to provide emergency voice evacuation signals. Refer to listee's Installation Instruction Manual for details. *12272016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-60760:13 • C-230 ECC-RM Remote Microphone General Firelite's ECC-RM is an optional Remote Microphone that is compatible with the ECC-501100(E) Emergency Command Center for fire protection applications. It is part of a family of external remote consoles that allows for extending the opera- tor interface to remote locations within a building. It is housed in a cabinet with a keyed or an optional thumb lock to limit access to qualified personnel. The ECC-RM remote microphone allows for ALL CALL paging to be broadcast over the speaker circuits when depressing the microphones push-to talk switch. The RM requires an external data bus connection, an external audio riser connection, and an external operator interface power connection (24 Volts DC) from the ECC-50/1 00 main console. TYPICAL APPLICATIONS Schools Healthcare Facilities • Factories Theaters Military facilities • Restaurants Auditoriums Places of Worship • Office Buildings Dormitories Features • External remote console that provides ALL CALL paging broadcasts over the speaker zones of the ECC-50/100(E) primary operating console. Modular design for maximum system flexibility and easy expansion. Supports both Class A (Style Z) and Class B (Style Y) wir- ing. A maximum of eight ECC-RM's can be connected to an ECC-50/100(E) primary operating console. Built-in microphone with push-to-talk feature that can be used for ALL CALL paging. Sturdy cabinet design with a keyed lock to prevent unautho- rized access. Optional thumb lock is available. Simple and straightforward user interface. Electrical Specifications PRIMARY POWER REQUIREMENTS: Voltage 24VDC non-resettable power from the ECC-50/ 100(E). External Operator Interface Power (Non-supervised). See ECC-50/100(E) Product Manual P/N LS10001-000FL-E for standby and alarm current requirements as well as battery calculations. Wiring Requirements See Product Installation Document PN: LS10029-000FL-E for detailed wiring requirements. Agency Listings and Approvals The listings and approvals below apply to the basic ECC-50/ 100(E) Fire emergency voice evacuation system. In some cases, certain modules may not be listed by certain approval (a FIreLuTeALarms by Honeywell agencies or listing may be in process. Consult factory for latest listing status. UL Listed S2424. CSFM: 7300-0075:0227 FDNY: COA #6152. FM Approved. Standards and Codes The ECC-RM complies with NFPA 101 Life Safety Code and with the following UL Standards and with NFPA 72 Fire Alarm system requirements. UL 864. Temperature and Humidity ranges This system meets NFPA requirements for operation at 049 C/327120 F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 1527 C/60-8051 F Cabinet Specifications 8.3" (21.082 cm) high x 6.080" (15.44 cm) wide x 4.337" (11.02 cm) deep (Door attached and closed). Shipping Specifications Weight: 4 lbs (1.81 kg). DF-60760:B • 8/26/14 - Page 1 of 4 CHG-75 charger I CHG-1 20F charger 7ri Internal cptions NAC Circuit Speaker Circuits TB19 TB21&TB21 ECC-50W-25/70V optional amplifier ECC-CE6 circuit expander El! 10 31~ L01 ECC-FFT firefighter telephone EM'RGEAI!CY COMMAND CEUI FIR ECC-LOC ECC-RPU ECC-RM local operator console remote paging unit remote microphone IN IN 1TL i1, ECC125DA 125W ECC-50DA 50W remote amplifier remote amplifier - I ECC-50BDA 50W remote amplifier external battery charger-J . 4 TB4 TB12 distributed audio T ,I: ECC-50/100(E) Emergency Command Center (Possible Configurations) Page 2 of 4— DF-60760:13 • 8/26/14 SYSTEM IN USE CD OK TO PAGE C) POWER C) DATA TROUBLE C) AUDIO TROUBLE C) MIC TROUBLE C) S S Control and Indicators PUSH BUTTON CONTROLS Microphone Push to talk switch LED STATUS INDICATORS (VISIBLE WITH DOOR CLOSED) System in Use (green) OK to Page (green) AC Power (green) Data Trouble (yellow) Audio Trouble (Yellow) Microphone Trouble (yellow) Product Line Information (Ordering Information) ECC-RM: Remote Microphone only. ECC-50/100: (Primary operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacuation system, Integral microphone, built in tone generator and 14 recordable messages. Please refer to the data sheet DF-60734 for more information. ECC-501100E: Export version (Primary operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacua- tion system, Integral microphone, built in tone generator and 14 recordable messages. Please refer to the data sheet DF- 60734 for more information. ECC-CE6: Speaker Circuit/Zone Expander Module. ECC50W-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100 power output to 100 watts or can also be used as a backup amplifier. ECC-50W-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/1 00 power output to 100 watts or can also be used as a backup amplifier. ECC-XRM-70V: 70V Transformer conversion module for 70V operation. ECC-LOC: Local Operator Console (Complete user interface), Please refer to the data sheet DF-60762 for more information. ECC-RPU: Remote Page Unit Hand held microphone, 14 message buttons. Please refer to the data sheet DF-60761 for more information. ECC-50DA: Distributed (Remote) Audio Amplifier, 50 watts. Please refer to the data sheet DF-60763 for more information. ECC-50BDA: Distributed (Remote) Audio Amplifier with backup, 50 wafts/1 00 watts at 25Vrms or 70Vrms. Please refer to the data sheet DF-60763 for more information. ECC-50WBU: Expander card for ECC-BDA remote amplifier for 100 watt primary/50 watt backup operation. Please refer to the data sheet DF-60763 for more information. ECC-125DA: Distributed (Remote) Audio Amplifier, 125 watts. Please refer to the data sheet DF-60763 for more information. ECC-50DAE: Export version. Distributed (Remote) Audio Amplifier, 50 watts, 240 VAC, 50 Hz. Please refer to the data sheet DF-60763 for more information. ECC-125DAE: Export version. Distributed (Remote) Audio Amplifier, 125 watts, 240 VAC, 50 Hz.Please refer to the data sheet DF-60763 for more information. ECC-CE4: Distributed Audio Speaker Circuit/Zone expander module. ECC-FFT: Fire Fighter Telephone System. Please refer to the data sheet DF-60765 for more information. FPJ-F: Remote Phone Jack. FHS-F: Fire Fighters Remote Handset. FHSC-RF: Fire Fighters Handset Cabinet Recessed. FHSC-SF: Fire Fighters Handset Cabinet Surface Mount. MMF-301: Addressable Mini-Monitor Module. 1300: SLC Line Isolation Module. TR-CE: Optional Trim Ring. ECC-MICROPHONE: Replacement Microphone Only. CHG-75: 25 to 75 ampere-hours (AH) external battery charger. CHG-120F: 25-120 ampere-hours (AH) external battery charger. BAT-1270: Battery, 12volt, 7.OAH (Two required). BAT-1 2120: Battery, 12volt, 12.OAH (Two required). BAT-12180: Battery,12volt, 18.OAH (Two required). BB-26: Battery back box - Mounts up to 2, BAT-12260 Batteries. BB-55F: Battery Box - Mounts up to 2, BAT-12260 or BAT- 12550s. MMF-300: Monitor module used to supervise dry contact input devices. THUMBLTCH: Optional Thumb Latch. (Non UL Listed). DF-60760:B • 8/26/14 - Page 3 of 4 ©2014 by Fire-Lite Alarms. All rights reserved. Unauthorized use of this doc- ument is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate ______________ We cannot cover all specific applications or anticipate all requirements. MSINEOUNS I MANIFACTINNS All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-60760:6 • 8/26/14 C S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: 7300-0075:0227 7300 .: FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com Page 1 of 1 DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: Models ECC-50DA, ECC-50DAE, ECC-125DA, and ECC-I25DAE amplifiers. Refer to listee's data sheet for additional detailed product description and operational considerations. 120V,6OHZ In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as amplifiers for use with separately listed compatible fire alarm control panels. Refer to listee's Installation Instruction Manual for details. 7300-0559:0173 07-08-13 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S EI July 8, 2004 DF-52301 • D-025 FCPS-24FS6 (B Firelffer ALarmS 24 Volt, 6Amp Remote Power Supply S www.firelite.com GENERAL The FCPS-24FS6 is a compact, cost-effective, 6-amp re- mote power supply with battery charger. The FCPS-24FS6 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expan- sion (to support ADA requirements and NAC synchroniza- tion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex (Commander Series) appliances. Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. Operates as a sync follower or a sync generator (default). * See note on reverse side. Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand- alone mode]). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation. Four Class B (Style Y) or four Class A (Style Z) (with ZNAC- 4 Module) Notification Appliance Circuits. 6.0 A full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864). 4.0 A continuous output in stand-alone mode (UL 1481). In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two. Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). Power-limiting technology meets UL power-limiting re- quirements. Form-C normally-closed trouble relay. Fully supervised power supply, battery and Notification Appliance Circuits. Selectable earth fault detection. Section: Power Supplies/Accessories zzíj ~7315-0075:206 7 ::re APPROVED LISTED MEA S2424 219-02-E AC trouble report selectable for immediate or 8 hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notifica- tion circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via dip switch for appli- cations requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. S Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product IS09001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all _____________________ requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING & MAMIFAC1IIRING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52301 07/08/04 - Page 1 of 2 STANDARDS and CODES The FCPS-24FS6 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Sys- tems (NAG expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand-alone mode). SPECIFICATIONS Primary (AC) Power FCPS-24FS6: 120 VAC 60 Hz, 3.2 A maximum Wire size: minimum 14 AWG (2.0 mm2) with 600V insu- lation. Control Input Circuit Trigger Input Voltage: 9.0 to 32 VDC. Trigger Current: 2.0 mA (16 - 32 V). (per input) 1.0 mA (9 - 16 V). Trouble Contact Rating 5.0Aat24VDC. Auxiliary Power Output Specific Application Power - 500 mA maximum. Output Circuits +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. 4.0 A maximum total continuous current for all outputs (Stand-alone mode). 6.0 A maximum total short-term current for all outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit Supports lead-acid batteries only. Float Charge Voltage: 27.6VDC. Maximum Charge Current: 1.5 A. Maximum Battery Capacity: 18 AH. ORDERING INFORMATION FCPS-24FS6 Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions. FCPS-2456RB Replacement mother board PN 90286 FCPS-24F Module Mounting Kit ZNAC-4 Class A (Style Z) NAC option module A77-716B 12/24 VDC end-of-line relay for monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt, 7.0AH (two required). APPLICATIONS Example 1 Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B (Style Y) outputs or 4 Class A (Style Z) outputs (using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 - DF-52301 07/08/04 Example 2 Use the FCPS-24FS6 to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-resettable and resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS-24FS6 inputs. Example 3 Use addressable control modules to activate the FCPS- 24FS6 versus the FACP Notification Appliance Circuits. This typically allows for mounting the FCPS-24FS6 at greater distances* away from the FACP while expanding system architecture in various applications. In this example, an addressable control module is used to activate the FCPS-24FS6 and an addressable monitor module is used to sense FCPS-24FS6 trouble conditions. Local auxiliary power output from the FCPS-24FS6 pro- vides power to the addressable control module. Tire-Lite's MS-9200, MS-9200UD, (198-point) or MS-9600 (636- point) addressable FACPs have the capability of locating control and monitor modules up to 10,000 feet (3048 m) away. Sync Follower/Generator Note: In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power, which are created by a Fire Alarm Control Panel such as the Fire-Lite MS-9600. When installed at the end of a MS-9600 NAC wire run, this power supply can track (i.e. "follow") the strobe synchro- nization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the addi- tional strobes attached to this power supply. When this power supply is configured (via DIP switch settings) as a "sync follower," this supply's NAC outputs track the strobe synchronization pulses present at this supply's sync input terminal. The pulses are originated from an upstream FACP or other power supply. When this power supply is configured (via DIP switch settings) as a "sync generator," this supply's sync input terminal are not used. Rather, this power supply is the originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315--POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Models FCPS-24F56 and FCPS-24F58 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S C fl SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD DOCUMENTS'." The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for docjmentation, passwords and system information ISO goof, Space Age Mader . REGiSiiRED/isae!! Electronics , m 508.485.0966 Local NFPA CO ly ,~PANY 800.486.1723 Toll Free MEMEWEAR Space Age Electronics, Inc. 2013 ED0584 LT10641 Rev.A 1/2 No Excuses, Just Solutions! .04012.222,0..2.,4th168.,4 782 1110644 582. I system information -off, maintenance & ernate locations PACE AGE E EL LECTRONICS',:, INCE Specifications: 0 The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system informatrn. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a stadard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00689 System Record Documents Cabinet RED SSU00690 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0584 LT10641 I Rev.A 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCXJA 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFXID enclosures. Models ACE-11, ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. S 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division LI! S 0 (uviMF.300(A) Series,) O (MDF-300J 1dressable Monitor ModuIes DF-52121:E • E-325 FIreuTeALarms by Honeywell S S General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75' (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. (MMF-300(A) Monitor Module) Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special TflUP*H ,l_cI.In MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. (maximum current draw: 5.0 mA (LED on).] (Average operating current: 375 iJA (LED flashing), 1 corn- (munication every 5 seconds, 47k EOLJ Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. DF-52121:E .07/30/2015 - Page 1 of 4 Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 1415 0 1 ADDRESS 0 1 I 13/\\2 2 g 11 1 LOOP I 5 8 76 9876 I TENS ONES lI I_ ilLu QH • ofl ..jH IIj Lul :: 110 ll j II 1I H ra The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K Ohms. External supply voltage (between Terminals TIO and T1 11): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. b300(A) Dual Monitor Modi) The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. S C S Page 2 of 4— DF-521 21:E .07/30/2015 NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. (Maximum current draw:6.4 mA (LED on).') fAve,,ge operating current: 750 pA (LED flashing)j Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0" to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. S Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424, ULC: S2424. FM Approved. ( CSFM: 7300-0075:0185j MEA:72-01-E. Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301 (A): Monitor module, miniature. 5 MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:E .07/30/2015 Page 3 of FireLite® is a registered trademark and LiteSpeed and FireWatch are trademarks of Honeywell International Inc. @2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. E111111190111 & MNIFACT1NG All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121 :E •07/30/2015 C df-60379:A1 • E-400 S Reiay Modui (2) FlreLrre®ALarms by Honeywell S General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 - 99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). < Average operating current: 230 pA direct poll (CLIP mode), < 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R5ms) Coded 30 VDC 0.5 A Inductive (LIR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01 -E Product Line Information > CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. S S LiteSpeedTM is trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try tc keep our product information up-to-date and accurate. 933=1=1 . . We cannot cover all specific applications or anticipate all requirements. INGINFEMNS A MANUFACTUMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - df-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION CAL OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1~ LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sénnett©Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: S *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S JIi S 0 CB- P-1 2ij 5 (Addressable Manual Pull Station) DF-52013:D • E-100 8 FlreLITeALarms by Honeywell General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. O Maximum SLC standby_qurrent:375 pA Maximum SLC alarm current:5mA Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed DF-5201 3:0 • 4/13/2012 - Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. (cSFM:7150-0O75:Oi84 FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. S FireLite® Alarms® is a registered trademark of Honeywell International Inc. @2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. _ ISO 9001 We try to keep our product information up-to-date and accurate. _________ 93M=1=1 We cannot cover all specific applications or anticipate all requirements. MSIMERING & MNIFACTIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:1) • 4113/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 701• FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneyweIl.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-I2WP, BG-I2LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-I2LPSP, BG-12SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 0- 0 0 LIFT HERE STI-i100 RD S PRODUCT OVERVIEW STI Stopper Il® FEATURES Proven effective for more than 30 years to help stop false fire alarms without restricting legitimate alarms. Can be used as a guard against physical damage to a manual pull station, with or without the optional warning horn. Optional horn has a choice of 95 or 105 dB at one foot. Standard red units have "In Case of u Fire..." label unless specified with "no L US label" or "custom label" (extra charge for custom label). aov . Horn housing is available in red, blue, ADA green or yellow with optional custom CompUaM BSA labeling. When covering a pull station outside, UL requires stations to be listed for outdoor use. Larger sizes and surface mounted pull stations accommodated with STl-3100 conduit spacer. Weather models have closed cell gaskets. Power source is a 9V DC alkaline battery included on standard Stopper II (remote powered unit available). "RC" models include one Form "C" dry relay contact and are capable of operating from 9-24V DC remote power or 9V DC battery power. Protect devices such as EPOs, call boxes, telephones and emergency shutdowns by changing the color and messaging. Stopper II consists of a clear, tamperproof, tough polycarbonate shield and frame, but Typical working properties of polycarbonate are -40" to 250°F (-40" the line includes models with the option of a piezo horn, spacer, Form "C" dry relay to 121°C). contact and gaskets. The cover accommodates most manual pull stations. When the The Stopper II design is a registered trademark of Safety Technology Stopper II with horn is lifted to gain access to the protected alarm, a piercing self- International, Inc. contained 95 or 105 dB warning horn (at one foot) sounds. Immediate attention is UL Listed to U.S. and Canadian safety drawn to the area and a prankster will either run or be caught. The cover is connected standards (also for custom labeling). Three year guarantee against to the frame by a cable. When the cover is lifted, it drops off of the frame and a horn breakage of polycarbonate in normal will sound (models with horn) until the cover is snapped back onto the frame or for the use (one year on electro mechanical S life of the battery. and electronic components). For more information, call 1-800-888-4784 (4STI) or visit www.sti-usa.com EM Safety Technology International, Inc. This protective cover has been helping to stop false fire alarms around the world for more than 30 years, without restricting legitimate alarms. All models offer excellent protection against physical damage (both accidental and intentional) and several against severe environments both inside and out. It is ideal for schools, colleges, hospitals, nursing homes, stores, hotels and public buildings of almost every kind where there is a threat of false alarms. HOW IT WORKS STI Stopper Il® Dimensions and Technical Information S MODELS AVAILABLE Stopper Il® Models Indoor Use STI-1100 With horn for flush mount STI11OORC* With horn and relay flush mount STI-1130 With horn and spacer STI113ORC* With horn and relay with spacer STI-1200 Without horn flush mount STI-1230 Without horn with spacer Weather Stopper5 with gaskets (Indoor/Outdoor rated) STI-1150 Stopper II with horn flush mount STI115ORC* Stopper II with horn and relay flush mount STI-1155 Stopper II with horn and spacer STI1155RC* Stopper II with horn, relay and spacer STI-1250 STl-1200 flush mount and gasket STI-3150 STI-1200 with spacer and gaskets Accessories STI-3100 2" conduit spacer with 1/2" conduit entry (no gaskets included) STI-3104 2" conduit spacer with 3/4" conduit entry (includes one 3/4" conduit entry gasket) STI-1102 Replacement horn for cover with alarm CUSTOM-LBL Custom text message for horn housing STI-1280 Backplate for Stopper II and Weather Stopper series HORN HOUSING COVER 5.5 in.(140mm)—n- A 3.2 0(81mm) n.1S8mm SPACER _ 8.5 in.(216mm) in.(51 mm) .1 SIDE VIEW MODELS WITH HORN (STI-1100 Series) :::"$'- 3.2 0(81mm) 7.0 in.(178mm)- 2 8.5 in.(216mm) in.(5lmm) SIDE VIEW MODELS WITHOUT HORN (511-1200 AND 511-3150 Series) APPROVALS & WARRANTY TESTING It has been tested and approved or listed by: UL/cUL Listed No. S2466 For fire alarm applications, UL38 requires outdoor listed stations for outdoor use Factory Mutual No. 0G6A2.AY (STl-1100 and STI-1130 only) State of California (obtain local fire marshal approval) MEA 49-00-E (STI-1200) Flush models ADA Compliant. Surface models ADA Compliant for operation (UL Certified No. S2466) 1P44 The indoor/outdoor rated station covers, when mounted on a smooth surface, provide a rain tight seal similar to a 3R enclosure rating. WARRANTY Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). IMPORTANT NOTICE Stopper II "FIRE" models are intended to be used in areas where the incidence of false fire alarms from manual pull stations is high or has proven to be a serious problem. Any disadvantage of this device is more than balanced when one considers the consequences of false fire alarms, especially if fire service personnel and equipment are responding to a false fire alarm when they are needed for a real fire somewhere else. Add to this the disruption to the facility when false alarms occur. If you have, or may have, a problem with false fire alarms or physical/weather damage to your fire alarm activation devices, the Stopper II could prove invaluable. *WARNING:AFor RC models: UL Listing does not permit relay contacts to connect to the fire alarm or a life safety function. The power supply for horns, according to UL Listing, cannot be connected to a UL Listed fire alarm system. For electrical specifications see install book. RC models contain one set of Form "C" dry contacts. Contacts rated 30 VAC/VDC 1 amp. I 11-3100 SPACER 3.2 in. o (76mm A I t A1(85) .(102m. t B I B 2.751n. 1(70mm) I I I I 5 in.(127mm) C I I I c 12.375 in. .— 1 I I I 5.5 in,(l4omm) E I (60mm) 1.625 in. I [0055 () nI . 75 .-n-------5.5 In.(l4tmm)—... 2' OEPTH(slmm) I 1(19mm) I ALL MODELS END VIEW EXTERNAL DIMENSIONS: • Flush 7.2 W x 10.2 H x3.3 Din. (183x259x84mm) Surface 7.2 W x 10.2 H x 5.5 D in. (183x259x140mm) ogy Safety Technol International, Inc. EEE Toll-free: 800-888-4784 Redditch, WorcestershireITel: 248-673-9898 Unit 49G Pipers Road Tel: 44 Fax:248-673-1246 Park Farm Industrial B98 OHIJ England EI Fax: 44iIII www.st:::: Printed in U.S.A., © 1987-2009 Safety Technology International, Inc. Subject to change without notice. 04/11 SD355(A) in B2IOLP(A) Base DF-52384:D • E-160 (W;55(A) Series) S (Addressable Photoelectric (Smoke Detectors General The SD355(A), SD355T(A), and SD355R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire-Lite's Addressable Fire Alarm Control Panels (FACP5). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indica- tion. Remote LED annunciator capability is available as an optional accessory, .PN RA100Z(A). The SD355R(A) is a remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: 01 - 99 with MS-9200UD(LS), S and 01 - 159 with MS-9600UD(LS). ARCHITECTURE Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. MECHANICALS Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0° (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (using a plaster ring - included). OTHER SYSTEM FEATURES Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Flre.uTeeAtarms by Honeywell OPTIONS Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. 5D355(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation SD355(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. SD355R(A) mounts in a 0355PL(A) or DNR(A)/DNRW duct detector housing. Operation Each 5D355(A) series detector uses one of 99 possible addresses on the MS-9200UD(LS) and up to 318 (159 on each loop) on the MS-9600UD(LS) Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the 5D355(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar cham- ber, the 5D355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DF-523840 • 2/11/2015 - Page 1 of 2 Detector Sensitivity Test SD355RA: Same as SD355R with ULC Listing for use with a D355PLA or DNRA duct detector housing; B21OLPA base Each detector can have its sensitivity tested (required per included. NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200UD(LS) or MS- INTELLIGENT BASES 9600UD(LS) addressable fire alarm control panel. The results NOTE: 'A" suffix indicates ULC Listed model. of the sensitivity test can be printed off the MS-9200UD(LS) or MS-9600UD(LS) for record keeping. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- Specification ing, see DF-60059. -.__. B21OLP(A): Plug-in detector base (included); standard U.S. Voltage range: 15-32 VDC (peak). flanged low-profile mounting base. S > Standby current: 300 pA @ 24 VDC. > LED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501(A): 4.1° (10.4 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter, - B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for 8D355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing Listings Listings and approvals below apply to the 5D355(A), SD355T(A), and SD355RT(A) detectors. In some cases, cer- tain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULListed:S1059. ULC Listed: S1059. > • CSFM: 7272-0075:0194. MEA: 243-02-E. FM approved. Product Line Information NOTE: °A" suffix indicates ULC Listed model. SD355: Addressable photoelectric detector; B21OLP base included. SD355A: Sames as SD355 with ULC Listing; B21OLPA base included. SD355T: Same as 5D355 but with thermal element; B21OLP base included. SD355TA: Same as SD355T with ULC Listing; B21OLPA base included. > SD355R: Remote test capable addressable photoelectric detector for use with a D355PL(A) or DNRNDNRW duct detector housing; B21OLP base included. 821 OLPBP: Bulk pack of B21OLP; package contains 10 B501(A): Standard European flangeless mounting base B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B35OLP(A) profile, or to convert older high-profile bases to low-profile. Fl 10BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RAlOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. 155-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with SD355(A) only; box of 10. WCK-200B: White detector covers for use with SD355(A) only; box of 10. FireLite® Alarms is a registered trademark of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. S This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product infOrmation up-to-date and accurate. KTrqrZ1K7T3rrTIYT11 We cannot cover all specific applications or anticipate all requirements. 01111901ING & MNIFACTIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2- DF-52384:1) • 2/11/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Models SD350, SD350T, 5D355, 5D355R*, SD3551 and AD355 photoelectric type smoke detectors. Model SD350T and 5D3551 has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models 5D355 and 5D355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and S System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S 0 N S (intelligent Bases) (Standard, Relay, Isolator, Sounder,) (ad Low-Frequency Sounder Bases] DF-60059:G • E-265 8 FlreuTe'ALarms by Honeywell S General Intelligent mounting bases and kits provide a variety of ways to install Fire-Lite detectors in any application. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selection (see Junction Box Selection Guide). Across this product line, detectors plug in easily to the base with SEMS screws; and models employ various 12 to 24 AWG wire ranges. Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non-tem- poral pattern versions depending on whether the signal is to be used for evacuation purposes. Low frequency sounder bases are UL listed for low frequency operation and comply with NFPA 72 requirements for sleeping spaces. This datasheet discusses the following bases: 13501(A), B200SR(A), B200SR-LF, B21OLP(A), 62241 Bl(A), 6224RB(A), mounting kits, and accessories. Specifications Diameter: B501: 4.1° (104 mm). B224Bl, B224RB, B21OLP: 6.1 (155 mm). B200SR, B200SR-LF: 6.875 (17.46 cm). Wire gauge: 6224B1, B224RB: 14 to 24 AWG. B21OLP, B501, B200B200SR, B200SR-LF: 12 to 24 AWG Temperature range: B224131, B224RB, B200SR, B200SR-LF: 32°F to 120°F (0°C to 49°C). B21OLP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. There- fore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings o C - 1. Flangeless Mounting Base B501 (A) Relay Base B224RB(A) B200SR(A) - Low-Frequency Sounder Base B200SR-LF 00SLF Aii33 0 Vb) AoVDC3 SLC operating voltage: 15 to 32 VDC. SLC standby current: See applicable sensor specification. Sound output: Greater than 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone). FOR B224RB, 8224B1: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB only): 20 msec maximum. Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0A @ 30 VDC. Mounting ?IOLP(A)l N S FOR 8200SR, 8200SR-LF: External supply voltage: 16 to 33 VDC (VFWR) tStài,dby current :3 ID 13200SR-LF:1rnA max. C B20OSR3A maximum! Product Line Information INTELLIGENT BASES B501: Flangeless mounting base. B501 A: Flangeless mounting base, ULC Listed. B501 BP: Bulk pack of B501 (10). B21OLP: Flanged mounting base. B21OLPA: Flanged mounting base, ULC listed B21OLPBP: Bulk pack of B21OLP (10). DF-60059:G • 2/3/2015 - Page 1 of 2 B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: ULC-listed version of B200SR. B200SR-LF: Low Frequency version of the B200SR; produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B224RB: Relay base. B224RBA: Relay base, ULC Listed. B224B1: Isolator base. B224B1A: Isolator base, ULC Listed. MOUNTING KITS AND ACCESSORIES SMB600: Surface mounting kit, flanged. F110: Retrofit flange for converting high-profile bases to low- profile. F110BP: Bulk pack of F110 (10). F210: Accessory flange ring for B210LP(A) base (new design). 6-inch diameter. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool for current heads (T55-127-010 included). XR2: Detector Remove Tool for use with low profile detector heads, and. XP-4: Extension pole for XR2/B (5 to 15 V.524 to 4.572 m). T55-127-010: Detector removal head. BCK-200B: Black detector kit, package of 10 (for use with photo and ion detectors). WCK-200B: White detector kit, package of 10 (for use with photo and ion detectors). Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S91 1. ULC Listed: S911, S1059. S F210BP: Bulk pack of F210(10). RA100Z: Remote LED annunciator. RA100ZA: Remote LED annunciator, ULC Listed. M02-04-00: Detector test magnet. Junction Box Selection Guide FM Approved. MEA: 22-95-E, 205-94-E Vol. 2; 257-06-E (ösFM 7300-1653:0109: 7300-1653:0126, 7300-1653:0213' Base Models Single Gang3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200SR, B200SR-LF Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Fire-Lite® Alarms and System Sensor are registered trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 1TrqlT_%_Z13T'An We cannot cover all specific applications or anticipate all requirements. QUALITY SYSTEMS All specifications are subject to change without notice. 5 For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Page 2 of 2— DF-60059:13 • 2/3/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 6401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, 6501B, 14506587-002, B501BH, B501 BHT, B401BH, B110LP, 13110RLP, B11ORLP750, B112LP, B114LP, 13114LPBT, 13116LP, B21OLP, B501-BL, B501-IV, *6501..wHITE B300-6, B300-6-IV, 6300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 S Rev 04-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S 0 S SYSTEM SENSOR Multi-Voltage Conventional Relays System Sensor's multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations The R-1 OT, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware.The R-1 OT is a single FORM-C (SPDT) relay with a red activation LED, and the R-141 is a four-gang 1 FORM-C (SPDT) relay with four red activation LEDs. The R-201 is a single 2 FORM-C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM-C (DPDT) relay with four red activation LEDs. Multi-voltage relays with terminal strip field wiring connections, The R-1OE/R-20E and R-14E/R-24E are similar to the T-series mounting track, and hardware for R-1 OT/20T and R-1 4T/24T track mount relays, but they are mounted into a steel enclosure. The Removable front cover on steel enclosure for R-1 OE/R-20E and R- enclosure has a removable front cover that provides easy access and • 14/R-24E, which mount inside the enclosure . an LED viewing hole on the top of the cover. • LED viewing hole on top of the steel enclosure's cover PR-i IPR-2IPR-3 are epoxy encapsulated multi-voltage relays. They • Extra pair of wires for redundant power input on PR-3 are single-pole double-throw relays that use a red LED as a visible Terminal strip field wiring connections, mounting track, and indication of relay coil energization. PR-3 is hardware identical to PR-2, except it has an extra pair of wires for redundant power input. Model EOLR-i is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. Agency Listings S 10 MEA LISTED II, Specifications: PR-1 Operating Voltage 18-35 VDC, 18-35 VAC, 120 VAC Operating Current 15 mA DC max. @24 VDC, 24 VAC, 120 VAC Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8" minimum Dimensions 0.871-I x 2.01W x 1.42D Contact Ratings 24 VDC: 7 A with [JR = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive S Multi-Voltage Conventional Relay Specificatu Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-i 01/8-141) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-201/R-241) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OT/R-201: 2.5"L x 3.35'W x 1.2'1-1 R-1 4T/R-241: 101x3.35Wx 1.21-1 Contact Ratings 24 VDC: 7 A with [JR = 5 mS 120 VAC: 1OA 120 VAC: 1/6 HP 230 VAC: 7 A Operating Voltage 18- 35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-1OE/R-14E) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20EJR-24E) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OE/R-20E: 5.11 x 3.75'W x 2.51-1 R-14E/R-24E: 11 'Lx 5.3'Wx 2.51-I Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8minimum Dimensions 0.91 1-1 x 1.65W x 1.22D Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Contact Ratings 24VDC: 7 A with [JR = 5 mS Operating Voltage 9 to 40 VDC 120 VAC: 10 A Operating Current 20 mA DC max. 120 VAC: 1/6 HP Operating Temperature -22°F to 140°F (-30'C to 60°C) 230 VAC. 7 A Humidity Range 10- 93% RH Wire Length 8' minimum Contact Ratings 120 VAC: 0.5 A max, (resistive load) 30 VDC: 3 A max. (resistive load) PR-i EOLR-1 PR-3 R-IOE& R-20E Enclosure P8-2 R-10T R-141 R-i4E & R-24E Enclosure 2007 Systo= Se,,o,. 3825 Ohio Avenue. St. Charles, IL 60174 Product specifi~tlws subject 1. ch~nge widlout notice. Visit sygerosenw—rn for 5El1J5 Phone: 800-SENSOR2 Fax: 630-377-6495 current product infonnation , including the lateu wmim of this cd~m sheeL CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-1653:0172 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models PRA, -2, -3 Multi-Voltage Relay. Refer to listee's data sheet for detailed product description and operational considerations. RATING: PRA = 24 VDC/ (+); 24 VAC; 120 VAC, 60 Hz PR-2,-3=10-40VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:232 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I Ji I 0 Product Listings C®US thi pccduc$ Mffii nici Litmdby L1ETES USOPATCRES, WC. BFP (City of Chicago) BS+AJMEA #285-91-E - XV CSFM 7135-0569:122 (GEH, GEC) 7125-0569:123 (GES) 7135-0569: 130 (GEH-12) FM Approved UL 464, UL 1971 & UL 1638 Listed CAN/LJLC S526-M87 Listed ULSZ7.S3406 Listed (GEC24, GEH24 & GEH12) Product Compliance NFPA72 Americans with Disabilities Act (ADA) NEM4 k1m 4 MEMBER ASSEM&ED IHEUSA Commander2 Series Low Frequency Evacuation Signals Applications The Commander2 Series is a low profile strobe, horn or horn/strobe combination that offers dependable audible and audible/visual alarms and the lowest current available. The GE Series is available in fixed candela options of 15, 30, 60, 75, 110, 177 and 15/75. The Commander2 Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime as well as a whoop tone. All tones are easy for the professional to change in the field by using switches. The GE Series has a minimal operation current and has a minimum flash rate of 1 H regardless of input voltage. The Commander2 Series is shipped with the standard 4" mounting S plate which incorporates the popular Super-SlideTM feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander2 Series also features the CheckmateTM - Instant Voltage Verification feature which allows the installer to check the voltage without removing the signal. The GE Series appliances are UL 464 and UL 1971, listed for use with fire protective systems and are warranted for three years from date of purchase. Standard Features Nominal Voltage 24 VDC (12 VDC available on GEH) Fixed Candela Options of 15, 30, 60, 75, 110, 177 and 15/75 Unit Dimensions: 5" high x 4.5" itide x 2.5" deep Prewire Entire System, Then Install Your Signals Super-SlideTM Bracket - Ease of Supervision Testing Checkmate1M - Instant Voltage Verification Lower Installation and Operating Costs Input Terminals 12 to 18 AWG Switch Selection for High or Low dBA Switch for Chime, Whoop, Mechanical and 2400Hz S Tone Switch for Continuous or Temporal 3 (not available on whoop tone) Tamperproof Re-entrant Grill GECIGES/GEH 24 VDC SERIES Surface Mount with the GSB (Gentex Surface Mount Box) Synchronize Strobe and/or Horn by Using the Gentex Synchronization Module (12 VDC product must use the AVSM Module) Silence Horn While Strobes Remain Flashing Wide Voltage Range 16-33 VDC or FWR Faceplate Available in Red or Off-White GEH 12 and 24 VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage Reverberant dBA @ lOft. Per UL4641 In Anechoic Room dBA @lOft. (3EH12-R 904-1239-002 12 VDC 70-82 100 (.iEH12-W 904-1241-002 12VDC 70-82 100 (3EH24-R 1 904-1205-002 1 24 VDC 70-82 1 100 GEH24-W I 904-1207-002 1 24 VDC 70-82 1 100 GEC 24 VDC Low Profile Evacuation Horn/Strobe Model Number Part Number _________ Nominal Voltage _______ Strobe Candela _________ Reverberant dBA © loft. Per UL464' Anechoic Room dBA © loft. GEC24-15WR 904-1125-002 24 VDC 15 70-82 100 GEC24-15WW 904-1145-002 24 VDC 15 70-82 100 GEC24-30WR 904-1129-002 24 VDC 30 70-82 100 GEC24-30WW 904-1149-002 24VDC 30 70-82 100 GEC24-60WR 904-1133-002 24 VDC 60 70-82 100 GEC24-60WW 904-1153-002 24 VDC 60 70-82 100 GEC24-75WR 904-1135-002 24 VDC 75 7782 100 GEC24-75WW 904-1155-002 24 VDC 75 70-82 100 GEC24-110WR 904-1139-002 24 VDC 110 70-82 100 GEC24-110WW 904-1159-002 24 VDC 110 70-82 100 GEC24-177WR 904-1143-002 24 VDC 177 70-82 100 GEC24-177WW 904-1163-002 —7= 177 70-82 100 i3EC24-15/75WR 904-1127-002 24 VDC 15 (UL1971) 75 (UL1638) 70-82 100 GEC24-15/75WW 1 904-1147-002 1 24 VDC 15 (UL1971) 75 (UL1638) 70-82 100 Notes: 0 The GE Series is not listed for out- door use. Operating temperature: 32° to 120°F (0° to 49° C) For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see technical bulletin number 014). To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. Model designations: = Wall Mount = Red Faceplate = Off-White Faceplate P = Plain (no lettering) - available on all models. Plain units are non-returnable. Agent bezel also available. GES 24 VDC Low Profile Evacuation Strobe Model Number Part Number Nominal Voltage Strobe Candela (3ES24-15WR 904-1165-002 24 VDC 15 GES24-15WW 904-1185-002 -747N7 15 (3ES24-3OWR 904-1169-002 24 VDC 30 (3ES24-30WW 904-1189-002 24 VDC 30 GES24-60WR 904-1173-002 24 VDC 60 (3ES24-60WW 904-1193-002 24 VDC 60 GES24-75WR 904-1175-002 24 VDC 75 GES24-75WW 904-1195-002 24 VDC 75 GES24-110WR 904-1179-002 24 VDC 110 GES24-110WW 904-1199-002 24 VDC 110 GES24-177WR 904-1183-002 24 VDC 177 GES24-177WW 904-1203-002 24 VDC 177 GES24-15/75WR 904-1167-002 24 VDC 15 (UL1971) 75 (UL1638) GES24-15/75WW 904-1187-002 24 VDC 15 (UL1971) 75 (UL1638) I GE-24 Product Strobe Current Ratings I Candela 15 30cd & 15/75cd 60cd 75cd llOcd 177cd 24 VDC 55mA 63mA 88mA 11 2M 136mA 186mA L 78mA 96mA 137mA 180mA 224mA 288mA GE-24 Product Horn Current Ratings Horn Mode Minimum dBA @ lOft. per UL464 (HIGH) Minimum dBA @ loft. per UL464 (LOW) Regulated 24VDC Max. Operating @ High Setting (mA) Temp 32400Hz 78 71° 28 lemp 3 Mechanical 76 70° 25 lemp 3 Chime 70* 66° 15 ontinuoua 2400Hz 81 74° 28 Continuous Mechanical 80 72* 25 .ontinuous Chime 70* 66° 15 Nhoop 82 69* 56 GEH-12 Product Horn Current Ratings Horn Mode Minimum dBA @ loft. per UL464 (HIGH) Minimum dBA ft loft. per UL464 (LOW) Regulated 24VDC Max. Operating ft High Setting (mA) Temp 3 2400Hz 76 69* 29 lemp 3 Mechanical 75 68* 26 femp 3 Chime 62 60* 13 Continuous 2400Hz 79 74* 29 Continuous Mechanical 78 72* 26 Continuous Chime 63° 61* 13 hoop 78 71* 55 The listed horn current draws are for the continuous tone mode. The tem3ora1 3 tone has a reverberant dBA @ lOft, per UL 464 is 77-83 with a horn current draw of 34rnA. ___________________ 2 RMS current ratings are per UL average RMS method. UL Max Current Rating is the maximum reverberant sound level required for public mode tire protection service. These settings are [Oeratin the horn in this mode at this voltage will result in not meeting the minimum UL 11* RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-1 7VDC for 12VDC acceptable only for private mode tire alarm use. Use the high dBA setting for public mode units). For strobes the UL Max Current is usually at the minimum listed voltage (16VOC for application (not applicable when using the chime tone. The chime tone is always private .-l\ M..t. Th.....,,.-..4 ...,...,,, 4,... +k 1..,.... ..;... 41... 1....,. 24VDC units) (8VDC for 12VDC units). For audibles the Max Current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. 0 Mounting Super-Slide TM Checkmate TM - Instant Voltage Verification The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measure- ments will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. Switch Locations SWITCH POSITION 4 5 Mechanical-Temp ON ON ON Mechanical-Cool OFF ON ON Hi-Temp OI\I OFF ON Hi-Coot OFF OFF ON Chime -Temp ON ON OFF Chime-Cool OFF ON I OFF Whoop ON OFF OFF Vhhoop OFF OFF OFF Switch Position 6 ON> HIGH dB OFF> LOW dB \ Switch positions I and 2 in the off position to select f I isolated horn and strobe power inputs. ON - 2 3 4 5 6 Conventional GES/GEC Series Wiring Diagrams S UL Listed Control Signai Signal Panel S* So S- Ho H S. S+ S- 1-1* H- r ENOOFLINE RESISTOR Supervised Signal Circuit END OF LINE RESISTOR S TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT FORINDEPEN STROBE 1SYNCHRONGED AND HORN OPE REMOVE JUM j ILEAVE JUMPER l SYNCHRONIZATION 10 ELIMINATE NFOR NOR NINPUTON MODULE LEAVE JUMPER IN PLACE ON SLAVE UNITS UNLESS SEPARATE v Sw AND OPERATE CONTROL OVER ROL OVER HORIN UNISON M I SIgnal I He I-I- & Ii WOO IS REQUIRED. END OF LINE RESISTOR FOR CLASS OARING ONLY AUDIBLE SIGNAL CIRCUIT I ENDUE LINE I 2 RESISTOR FOR I ') 1—. i ArRIN5 ONLY SYNCHRONIZATION __________ MODULE I Signal ir ii Wiring Diagram GE Series with Gentex Synchronization Module F.A.C.P. VISIBLE SIGNAL CIRCUIT END OF LINE RESISTOR FOR .RING ONLY END OF LINE RESISTOR FOR CESSNA 09USD ONLY. Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GEH-12 VDC Series, the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE Series or approved equal and shall be)Fisted by Underwriters Laboratories Inc. per UL 1971, UL 1638 and/or UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audibleMsible and audible units only) shall produce a peak sound output of 100dBA or greater as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 H or up to 2Hz regardless of power input voltage. The appliance shall also be capable of meeting the candela requirements of the ADA (75Cd) for the combination listed (UL 1971/UL 1638) listed models. The appliance shall have an operating current of 63mA or less at 24 VDC for the 15/75Cd for the strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 27 pounds per carton MCI ~ p___ Fire Protection Products: www.gentex.com 10985 Chicago Drive Box 310 • Zeeland, Michigan 49464 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax Gentex Corporation reserves the right to make changes to the product data sheets at their discretion. Important Notice: These materials have been prepared by CentRe Corporation "Gentex") for informational purposes only, Are 551004901 necessarily Summary, and are not purported to servo as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation at laws, regulations and rules and the application 01 such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. 0 Printed on Recycled Paper CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0569:0123 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Gentex Corporation10985 Chicago Drive, Zeeland, MI 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestric@gentex.com DESIGN: Models ST24-15, S124-15/75, 5T24-30, ST24-60, S124-75, S124-110, GES24-15, GES24-15/75, GES24-30, GES24-60, GES24-75, GES24-110, GES24-177, and GES3-24 strobe lights; followed by suffix -W (wall mount), followed by -W or -R (white or red). Intended for indoor use and wall mount only. Model GCS-24 strobe light; followed by W or R (white or red color) and P (plain). For indoor use on wall or ceiling mount. Model AVSM Sync Module intended for indoor use with Gentex synchronizable strobe lights. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Candela: 15cd, 15cd & 75cd at 00 angle axis 30cd, 60cd, 75cd, 110cd, 177cd. Model GCS24: Selectable 15cd, 30cd, 75cd, 95cd, 115cd, and *150cd Model GES3-24: Selectable 15cd, 30cd, 60cd, 75cd and 110cd. Electrical: 21-30 VDC Model AVSM: 8-33 VDCNFWR Flash Rate: 60 flashes per minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances S and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical and candela ratings and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 09-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 'RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SSPK24WLP Series Wall Mount Speaker/Strobe 12 units per carton, 17 pounds per carton Applications The Gentex SSPK24WLP Series is a wall mount, selectable candela speaker/ strobe designed to meet code requirements for audio, visual and voice communications. The SSPK24WLP Series are quality speaker products offering both dependable evacuation signaling and visual alarms, or a combination of both. The high output tamperproof candela selections are 15, 30, 60, 75, 110. A fixed 15/75 candela unit is also available. The SSPK24WLP can be mounted in a 4" square x 2-1/8" deep back box, an extension ring is not needed. The SSPK24WLP Series provides a 25 or 70.7 VRMs speaker with field selectable power taps of 1/8W, 1/4W, 1/2W, 1W, 2W or 4W. The SSPK24WLP devices are listed to ANSI/UL 1480, the selectable candela strobe unit is listed to ANSI/UL 1971. The 15/75 candela unit is additionally listed to ANSI/UL 1638. The SSPK24WLP are also listed to CAN/ULC 5526 and/or CAN/ULC 5541 listed and are warranted for 3 years from the date of purchase. Standard Features Speaker/strobe nominal voltage 24 VDC 24 VDC field selectable candelas: 15, 30, 60, 75,110 24 VDC fixed 15/75 unit available Unit dimension: 6.1" (15.494 cm) square x 3.89" (9.88 cm) deep Speaker voltage 25 or 70.7 VRMs standard, field selectable • Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W,2W,4W High quality dBA output (intelligible) Frequency range 400-4000 Hz Screw terminals, separate in/out wiring (12-18 gauge) Mount to a standard 4" x 2-1/8" deep back box Synchronize with Gentex AVSM Control Module Tamperproof grill Faceplate available in red or off-white Wall mount SSPK24WLP Strobe Current Ratings (mA) 24 VDC (16-33 Volts) F Product Listings SIGNALING --- C @ us S LISTED ANSI/UL 1480, ANSI/UL 1971 and ANSI/UL 1638 Listed 24CSFM: 7320-0569:140 MEA: 580-06-E Vol.3 SSPK24WLP Speaker/Strobes Model Number Part Number Letterinq SSPK24WLPR 904-1413-002 FIRE Text SSPK24WLPW 904-1415-002 FIRE Text SSPK24WLPAR 904-1403-002 ALERT Text SSPK24WLPAW 904-1404-002 ALERTText S5PK24-15/75WLPR 904-1417-002 FIRE Text SSPK24-15/75WLPW 904-1419-002 FIRE Text 55PX24-15/75WLPAR 904-1403-002 ALERT Text SSPK24-15/75WLPAW 904-1406-002 ALERT Text R = Red Faceplate, W= White Faceplate A = ALERT text (speaker/strobe only) All units are available in plain (no lettering) Plain units are not returnable Candela 24 VDC UL Max 15 55 mA 78 mA 30 63 mA 96 mA 60 88 mA 137 mA 75 112 mA 180 mA 110 136 mA 224 MA 15/75 63 mA 96 mA Speaker dBA @10 ft. Input Watts 25 Volts 70.7 Volts 1/8 74.6 dBA 73.7 dBA 1/4 77.7 dBA 76.7 dBA 1/2 • 80.5 dBA 79.6 dBA 1 83.1 dBA 82.5 dBA 2 85.6 dBA 85.4 dBA 4 87.9 dBA 87.9 dBA Product Compliance Americans with Disabilities Act (ADA NFPA72 lBC/IFC/IRC Quality Management System is certified to: ISO 9001:2008. I 15.49 cm 6.1" H 15.49 cm SSPK24WLP Series Low Profile Wall Mount Speaker/Strobe Wiring SPEAKER Diagram 25 OR 70V SOURCE STROBE 24V POWER SOURCE H9.88 cm ?PFLWCE Notes -p. •es II EOLR Operating temperature: 32° to 120°F (0° to 49°C) The SSPK24WLP Series is not listed for outdoor use EOLR ;TB_ SPK (STROBE) (SPEAKER) WIRE CONDUCTIVITY 18AWG 60 16AWG 95 I4AWG 153 12AWG 244 For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see MAX. WIRE DISTANCE (IN FEET) = PANEL VOLTAGE -DEVICE MINIMUM VOLTAGE x WIRE CONDUCTIVITY (STROBE ONLY) installation manual TOTAL CURRENT DRAW • This appliance is not recommended for use on coded or pulsing signaling circuits Architect & Engineering Specifications The fire alarm speaker shall be Gentex SSPK24WLP or approved equivalent and shall be listed by Underwriters Laboratories, Inc. (ANSI/UL) per ANSI/UL 1638, ANSI/UL 1971, ANSI/UL 1480 and with CAN/ULC 5526 and/or CAN/ULC 5541 Listed. The speaker shall be capable of producing alarm tones or voice on all 25 or 70.7 VRMs audio systems. The speaker shall provide incremental tap settings of 1/8, 1/4, 1/2, 1,2 or 4 watts. Minimum dBA rating at 1/4 watt shall be 76.7 dBA at 70.7 volts and a minimum dBA rating at 4 watts shall be 87.9 dBA at 70.7 volts. Tap settings shall be adjustable with field selectable jumper pins. The speaker also has a visual signal with an operating current of 78 mA or less at 24 VDC for the 15 Cd strobe circuit. The strobe appliance shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24 volt models. The visual signal shall have a 1 Hz flash rate regardless of input voltage. All field wiring connections shall be made via separate in-out terminal connections. The SSPK24WLP shall be mounted on the wall. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7320-0569:0140 Page 1 of 1 CATEGORY: 7320 -- SPEAKERS LISTEE: Gentex Corporation 10985 Chicago Drive, Zeeland, Ml 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestric@gentex.com DESIGN: Models SSPK24WLP and 55PK24-1 5175WLP speaker strobes. May be followed by suffix -P, -W, or -R (plain, white, or red color). *Models SSPKA24-15/75 (amber), SSPKB24-1 5/75 (blue),SSPKG24-1 5/75 (green), and SSPKR24-1 5/75 (red). May be followed by A (alert), P (plain) and then followed by W (wall), then followed by R (red) or W (white) All models are intended for indoor use only and are wall mounted in a listed double-gang backbox. *Models WSSPK24-15175 speaker strobes. May be followed by A (alert), P (plain) then followed by W (wall), then followed by R (red) or W (white). Models WSSPKA24-15/75 (amber), WSSPKB24-15/75 (blue), WSSPKG24-15/75 (green), and WSSPKR24-15/75 (red), may be followed by A (alert), P (plain) then followed by R (red) or W (white). All models are intended for outdoor use on a wall with the Model GBLP back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Speaker 25 Vrms and 70.7 Vrms . Strobe Flash Rate 24 VDC 60 flashes per minute Candela 15, 30, 60, 75 & 15/75, 110 for Model SSPK24WLP 15/75 fixed candela for Model 55PK24-15/75WLP INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, ratings, and UL label. APPROVAL: Listed as speakers and speaker strobes for use with separately listed compatible fire alarm control units. Models are suitable for the hearing impaired applications. For indoor or outdoor use. Refer to manufacturer's Installation Manual for details. These devices do not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. 08-12-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division