Loading...
HomeMy WebLinkAbout1630 FARADAY AVE; ; FA060017; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA060017 Fl Job Address: 1630 FARADAY AV Permit Type: FALARM Parcel No: 2121302200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 5/5/2006 Approved: 5/8/2006 Issued: 5/8/2006 Inspector: Project Title: INTERIOR SPECIALISTS Owner: EBEL TRUST 10-14-83 Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 3308 CORTE CADIZ CARLSBAD CA Total ($) fBalance($) Parsley Consulting Engineers 350 West 9k Avenue, Suite L Escondido, California 92025-5053 T111011 (760) 7456181 Fax(760) 7450537 May 5, 2006 Karyn Vaudreuil City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Fire Alarm System Review for Interior Specialists, Inc., 1630 Faraday, Carlsbad, CA Dear Ms. Vaudreuil: We have reviewed the submittal as prepared by ADT. We do recommend approval of said plans and product submittals subject to our comments which are enclosed. Further submittal should not be required. Sincerely, P EY ,OU)NG ENGINEERS FZenneth W. PA WagoneT Office Manager End (1) Working Drawings - 2 sets Product submittals - 2 sets Review Comments - 1 set oteA copy of this letter has been transmitted via fax to ADT on May 5, 2006 f1e:\C:\REVIEWS\Rev206236.00 1.wpd 'I Interior Specialists, Inc. Review Comments. Review Comments Interior Specialists, Inc., 1630 Faraday, Carlsbad, CA 1. Field verify that the "open office" area on the first floor has interior walls which are not full fr" height, or an additional notification appliance will have to be installed in the corridor. FAo(,00rj- INTERIOR SPECIALISTS, INC. 1630 FARADAY CARLSBAD,CA. 92008 IW, FIRE ALARM SUBMITTAL APPROVED AS SUBMITTED - CARLSBFARTMENT c ?cJO 00b \ •çcPI rs \ CC \ wvG w \ o Ci \ r Submitted By: MA_ 3830 Calle Fortunada San Diego, CA 92123 (858) 654-3173 Contact: STACEY TESCIER INTERIOR SPECIALISTS, C. FIRE ALARM SUBMITTAL DESCRIPTION MODEL # MANF. CSFM# FIRE ALARM CONTROL PANEL ADT-6008 ADT 7165-1.574:195 REMOTE ANNUNCIATOR ADT-2001 ADT 7120-1574:193 FIRE ALARM POWER SUPPLY ADT-3501 ADT 7300-1574:135 SMOKE DETECTOR ADT-3201 ADT 7272-1574:187 HEAT DETECTOR ADT-3203 ADT 7272-1574:187 INPUT MODULE ADT-3102 ADT 7300-1574:189 RELAY MODULE ADT-3103 ADT 7300-1574:189 MANUAL PULL STATION ADT-3401 ADT 7150-1574:190 DUCT DETECTORS (EXISTING) BY OTHERS HORN/STROBE MULTI CANDELA WALL MNT T371-9304 ADT 7125-1597:126 HORN/STROBE MULTI CANDELA CLGMNT T371-9305 ADT 7125-1597:126 STROBE MULTI CANDELA CLGM]JT T371-9408 ADT 7125-1597:127 18/2 FIRE CABLE 740132 ADT/PAIGE/GENISIS 7161-1487:100 14/2 FIRE CABLE 740133 ADT/PAIGE/GENISIS 7161-1487:100 18/4 FIRE CABLE 740134 ADT/PAIGE/GENISIS 7161-1487:100 CONNECTION TO EXISTING WATERFLOW, TAMPER, SUPERVISORY SWITCHES CONNECTION TO EXISTING DUCT DETECTORS ADT-6008 Standard Control Panel ADT-6008A Control Panel with 24 LED Annunciator Dserintit For areas requiring up to 200 addressable input devices and up to 4 NACs, the ADT-6008 Series tire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and LCD annunciated circuit-specific 20 character Custom labels. See page 2 for specific listing information. This product has been approved by the California State Fire Marshall ICSFM) pursuant to Section 13144.1 at the California Health and Safety Cole. See CSFM Ustiog 7165-1574:195 for allowable values and/or corditions concerning material presented is this document It is su4ect to re- examination, revision, and possible cancellation. Accepted for use - City of New York Cepailnt of Buildings MEA 205-E. This product was not ULC isteC as Of 000sjroent revision date. UL !is" is under le number 3232. Additional listings may be applicable, contact your local AOl product supplier for the latest status. Uniscan addressable snake detection is protected by one or more of the following U.S. Patents: 5,155,458; 173,653:5,543,777. Uniscan addressable communications are prcledai by U.S. Patent No. 4,7,025. Uniscan duplicate device detection is protected ureter U.S. Patent No. 6,034,601. Wstktest system testis protected under US Patent No. 4,725,818. Two-wed horn/strobe canted operation is protected under U.S. Patent No. 6,281,789. Two-we synchronization dlcUi operation is protected by U.S. patent No. 5,559,492. A0T6008-01 Rev 3 11/2005 tIJCO! Fire & Fire Alarm Control Panels Security UL, CSFM Listed; FM Approved; Unimode AE ADT-6008 Fire Alarm Control Panels MEA (NYC) Acceptance* for up to 200 Uniscan Addressable Devices a= Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient panel status information Operation is programmable using a multi-function keypad and the panel LCD or via service computer (PC) RS-232 service port provides upload/download PC access for panel configuration and event history logs Software updates are via PC download Convenient library of standard custom label terms Standard on-board DACT provides: Contact ID, 3/1, 4/2, BFSK., and SIA formats Walktest silent or audible system test** Voltage and current for both the battery charger and the battery can be displayed at the front panel LCD Addressable Devices: Using Uniscan communications, up to 200 addressable Uniscan detection points or addressable device points are available (see page 3 for details)** Two Standard Notification Appliance Circuits (NACs): Class A or Class outputs with solid state overcurrent protection per NAC, each rated for 2 A Selectable for two-wire horn/strobe control or synchronized strobe control Standard Power Supply: Provides 3 A maximum nominal 24 DC Automatic input power selection operates with 120 VAC, 60 Hz On-board temperature compensated battery charger for sealed lead-acid batteries up to 12 Ah (typical) in cabinet and up to 25 Ah in separate cabinet (see page 5 for details) Additional standard features: Two auxiliary relays NACs, Relay outputs, and communications circuits are power limited per NFPA 720' (AC input, battery circuits, and City Circuit Module outputs are non-power limited) UL listed to Standard UL 864, 9th Edition Available option modules: Door mounted 24 LED annunciator 3 A Expansion Power Supply with two on-board 2 A NACs that operate the same as standard NACs ç • City interface Module and Auxiliary Relay Module Remote LCD and LED/Switch Annunciator FIEMJ GGNTROL I ifl7IHTrzi aITlL1 Addressable operation is provided by a Uniscan signaling line circuit (SLC) capable of communicating to up to 200 addressable devices (points). Addressable devices include: Uniscan smoke detection, heat detection, and duct detection: supervised addressable modules for single and multiple contact monitoring, manual stations, isolation modules, and a remote signal module (see list on page 4.) Two, 2 A On-Board NACs provide conventional reverse polarity operation, selectable as Class A or Class B, with electronic control and overcurrent protection. Operation is selectable for synchronized strobe or horn/strobe two-wire operation. Horn control can be selected at the panel for: Temporal pattern coding, Steady On, Slow March Time (20 beats per minute), or Fast March Time (120 beats per minute). Note: When selected for 2-wire horn/strobe control, March Time produces 60 beats per minute. The 24 VDC Auxiliary output provides up to 500 mA for system use. (Auxiliary output current is counted for total power supply capacity.) Standard Auxiliary Relay Outputs. Two relay outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC per below: Aux Relay I is normally assigned to General Alarm operation but is programmable (see page 7) Aux Relay 2 (Trouble) is energized when Normal and is de-energized with a Trouble condition. On-Board Dual Line DACT. Operation can be selected for Contact ID, SIA, 3/1, 4/2, and BFSK formats. Reporting includes Alarm, Supervisory, Trouble, and AC Failure. Operation includes automatic 24 hour test and programmable power fail report delay. Power Supply and Battery Charger. DC power output is 3 A 24 VDC for panel use. The temperature compensated battery charger (sealed lead-acid batteries only) is rated for up to 25 Ah batteries per UL 864. (Up to 12 Ah (typical) batteries fit in the cabinet, larger batteries require an external cabinet, see page 5 for details.) Panel electronics can measure and display voltage and current for the power supply, batteries and the battery charger (standard and expansion power supply). Depleted battery trouble is monitored and annunciated and depleted battery cutout can be selected. Active battery status monitor supervises charger operation. LOT M. 1112711TIT-317-71M Expansion Power Supply. Provides 3 A total 24 VDC, two additional 2 A NACs, and an additional auxiliary power output of 500 mA. Output operation is the same as on the standard power supply. Expansion Relay Module. Provides three relays, one each for Alarm, Supervisory, and Trouble conditions. Each is jumper selectable as N.O. or N.C. Contacts are rated 2 A @ 30 VDC. Location is the same as for the City Circuit Modules. City Circuit Modules. These modules are available with or without on-board disconnect switches, depending on local requirements (either type can be disconnected through the front panel under password control). Connections are for Remote Station (reverse polarity) or Municipal Master (local energy). Reporting includes Alarm, Supervisory, and Trouble. Product Selection Listings Box Depth Standard Features UL, CSFM. FM & MEA ADT-6008A Fire alarm control panel with UL, CSFM. 24 LED Annunciator on front door & FM Option Modules Model I Description ADT-6008PS Expansion Power Supply; 3 A, with 2 NACs, 120/240 VAC, I Select one if required 50/60 Hz ADT6008RL Expansion Relay Module e;ect one f required ADT-6006CTYD' City Circuit Modules with disconnect switch ADT-6006CTY Select one if required. City Circuit Modules without disconnect switch I Accessories Model Description AD T-360 I Red External Battery Cabinet for up I Mounts close-nippled to control panel cabinet; dimensions = to 25 Ah batteries; without charger 16-1/4"W x 13-1/2" H x 5-314"0 (413 mm x 343 mm x 146 mm) 1309-9801 Red semi-flush trim kit: 1-7/16' (37 mm) wide: includes four corners and trim pieces for top, bottom, and sides These City Circuit modules are also used on the 6006 Series control panels. 4 ADT6008-411 Rev 3 11/2005 Control Panel Model Description ADT-6008 I Standard fire alarm control panel 41/4' Red cabinet: SLC with 200 addressable points; (108 mm) 2 Class 6/Class A NACs. 3 A power supply with 4-513' battery charger; on-board DACT; for input voltage (117 mm) of 120/240 VAC, 50/60 Hz (autoselect) SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal ALPHANUMERIC KEYPAD KEYPAD provides programming entry of numbers and letters .0 --------------- 6 11 *11WIMI Fir. FT.T. R. 173MM .1 MRVIM Uniscan System Operation. Uniscan addressable device compatibility includes Uniscan photoelectric smoke and temperature addressable detectors. The ADT-6008 lire alarm control panel provides a subset of the complete analog Uniscan features. Uniscan sensors appear to the panel essentially as addressable detectors and that term is used for ADT-6008 documentation. Approximately every four seconds, the smoke addressable detector transmits an output value based on their smoke chamber condition. The panel CPU internally maintains a current value, peak value, and an average,value for each addressable detector's output. Status is determined by comparing the current value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Alarm Determination. Photoelectric detention sensitivity is 2.51/o/ft obscuration. All detectors can be selected for a reduced sensitivity detection mode that satisfies Boston requirements. Addressable heat detectors provide a fixed temperature alarm at 1350 F (57° C) and may be individually selected to also provide rate-of-rise alarm of 15° F (8.3° C) per minute where applicable. !"Diagnostics andI Default Device Type-:,- Status Monitoring. Uniscan operation provides the ability to automatically indicate when an addressable detector is dirty or excessively dirty. The NFPA 72 (National Fire Alarm Code) requirement for a test of the sensitivity range of the addressable detectors is fulfilled by the Uniscan ability to maintain the sensitivity level of each addressable detector. Modular Addressable Detector/Base Combination. Modular Uniscan addressable detectors use the same base that allows different addressable detector types (photoelectric smoke, or heat) to be easily interchanged to meet specific application requirements. This feature also allows intentional detector substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke detectors (causing them to be disabled), heat detector heads may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect addressable detector type, the heat detector will operate at a default setting to provide heat detection for building protection at that location. I [Keyboard Reference FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condemn and then when acknowledged, remain on until reset THREE PROGRAMMABLE LEDs provide custom labeling (labels insert into 2 X 20 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 20 characters for custom label information a pocket), the top two LEDs are [ FIRST ALARM DISPLAY: Operation can be selected for maintained dispidy of first 1 selectable as red or yellow, the bottom alarm until acknowledaed LED is selectable as green or yellow o ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, )- and steps through the active Alarm list I Al SUPV acknowledges system supervisory conditions, logs the acknowledge, silences the operator LO panel and all annunciator tone-alerts, and steps through the active Suervisory list FIVE NAVIGATION KEYS: MENU selects the on-screen programming menu: loft and right arrows moves the position on the screen, and PREVIOUS and NEXT navigate screen selections I J ALARM SILENCE causes audible notification appliances TROUBLE ACI( acknowledges to be sile annunciator steps 3 A0T6008-01 Rev 11/2005 nced, used after evacuation is complete 5511 system troubles, logs the while alarm source is being investigated acknowledge, silences the operator panel and all tone-alerts, and steps through the FOUR EXTENDED FUNCTION KEYS: ENTER confirms active Trouble list selections, EXIT/CLEAR backs Out of the present screen menu and clears information that has not been entered, FUNCTION enables the active (unction menu, DISABLE)ENABLE toggles the function or circuit status as appropriate per the selected screen Ie!.IuJ .iflF_! B1 1M. Addressable Detectors and Bases (refer to page 3 for detector terminology) S Detector Detector Type Compatible Bases Data Sheet ADT-3206. Standard Uniscan addressable detector base without remote LED connection ADT-3207, Uniscan addressable detector base with remote LED ADT3200-01 ADT-3201 Photoelectric connection ADT-3203 Heat, 135' F (57 C) ADT-3208, Features of ADT-3207 and remote supervised relay ADT-3210, Sounder base ADT3200-05 ADT-3209, Uniscan Isolator base ADT3200-04 ADT-3202 Photo and Heat ADT-3211, Dual address sounder base j NOTE: These bases require ADT3200-02 ADT-3212. Dual address standard base I two addresses Duct Detection ADT-3204 Duct Addressable Detector Housing with ADT-3201 addressable detector, no relay control ADT32003 ADT-3205 Duct Addressable Detector Housing with ADT-3201 addressable detector, with remote relay control Addressable Devices Model and Description Data Sheet Model and Description Data Sheet Model and Description Data Sheet ADT-3102 Supervised ADT3100-01 ADT-3105 CL B ZAM I ADT3IOO-04 ADT-3101 Signal Zone ADT3100-03 Monitor Module I Module ADT-3103 Relay Module f I ADT3100-02 ADT-3104 Uniscan I ADT3IOO-05 ADT-3401, ADT-3402 ADT3400-01 Isolator Manual Stations Compatible System Expansion Panels Model Type Description Data Sheet ADT-6003 I Provides a remote voice control panel with on-board NACs. internal Voice Control Panel I ADT6003-01 Series microphone, and remote microphone input ADT-3550 Remote NAC Extender Provides remote NJAC5: includes power supply and battery charger; ADT3500-01 Series hardwire control mode, 4 extenders max/NAC output (a Note: Contact your local ADT Product Supplier for additional compatible peripherals nte Annunciatnr Ontic The ADT-6008 supports up to four annunciator options: ADT-2001 LCD Annunciator Features: Door Mounted 24 LED Annunciator LCD readout with two lines of 40 characters each and ADT-2000 Remote LED/Switch Annunciators LED backlighting ,"\DT-2001 Remote LCD Annunciators Wide viewing angle, super-twist design Annunciators communicate at a rate of 9600 baud with Keyswitch access controlled power supplied by separate wiring. Refer to data sheet ADT200I-01 for additional details ADT-2000 LED/Switch Annunciator Features: Control switches and status LEDs for: 16 LEDs with programmable functions and dedicated Alarm, supervisory, or trouble acknowledge LEDs for Alarm Silenced, Lost Communications, Alarm silence and System Reset Trouble, and Power-on Keyswitch access controlled switches for Three programmable LED indicators: Acknowledge, Alarm Silence, Reset, and Lamp Test Two LEDs are selectable as red or yellow Local tone-alert One LED is selectable as green or yellow Refer to data sheet ADT2000-01 for additional details With provisions for custom labeling ADT-2000 LED/Switch Annunciator I 5YSTE" - 1 I35Scis, WtN 28 MAP aS -. --:- •.. ADT-2001 LCD Annunciator 4 AOr8008-01 Rev 3 11/2005 Ipcati0ns (Refer to Installation Instructions 579-595 for additional information) 1 'i AC Input Input Voltage 1 120 VAC, 60 Hz; 220/2301240 VAC, 50(60 Hz, auto-select Input Current, Standard 12 A maximum @ 120 VAC input; 1.5 A maximum @ 240 VAC input 4 A maximum @ 120 VAC input; 3 A maximum @ 240 VAC input Input Current with Expansion Power Supply Power Supply Output 13 A maximum @24 VDC in alarm - Battery Charger Capacity; for 24 VDC sealed lead-acid battery system; typically (2) 12 VDC batteries in series Temperature compensated charger is rated for up to 25 Ah per UL 864; series connected 12 VDC batteries must be matched (same model and date code) Cabinet accepts (2)12 VDC batteries, each sized up to 6 W x 4" D x 4" H (153 mm x 102 mm x 102 mm) including terminals (typical of 12 Ah); check battery size before installation; use remote battery cabinet for larger batteries Notification Appliance Circuits (NACs) (NOTE: Total DC current = 3 A maximum per power supply) I 2 A maximum @ 24 VDC. per NAC; available as Class A or Class B; General Rating Class B end-of-line resistor= 10 kfl, 1/2W; Model TEPG-US T301 -9008 TEPG-US Series (horns) and the following Multi-Candela: strobes, horn/strobes, and speaker/strobes (see AD T-6008/6008A Un/mode AE Fire Alarm Panel Special Application Rating = per NAC Installation, Programming, and Operating Instructions, 579-595 for a complete list Strobe synchronization is UL listed across all of supported appliances.) four system NACs for these appliances 1371-9407 I 13719409 T371-9304 I 1371-9308 I 1371-9306 1371-9307 I 1371-9408 I 1371-9410 T371-9305 I 1371-9309 I 1371-9310 I Regulated 24 VDC Rating i5A per NAC NOTE: Maximum strobe load on main power All other UL Listed Notification Appliances; use associated external supply or expansion power supply is j 4 per synchronization modules where required power supply (2.7 A total); remainder of power supply rating is available for other loading - Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum per power supply) Auxiliary Power Output I 500 mA maximum @ 24 VDC Standard Auxiliary Relay Outputs Relay 1 Programmable operation Contacts rated 2 A@ 30 VDC, 0.35 power factor; Relay 2 Trouble operation jumper selectable as N.O. or N.C. Wiring Connections I Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) i tiniscan Communications Quantity Up to 200 addressable devices (see list on page 4) Suppression For wiring external to building, use Overvoltage Protector TEPG-US 1301-0001 at each end of the connection; refer to data sheet 1301-10 for details Wire Size 18 AWG (0.82 mm2) minimum Unshielded twisted pair (UTP) Acceptable for most applications: not for use with wiring in conduit with either Wire Types NAC or AC power wiring (or similar) Shielded twisted pair iSTPr Shielded wire may provide protection from unexpected sources of interference and may be required for some applications Distance from Control Panel to Farthest Device Up to 4000 feet (1219 m) with 125 devices; 32 ci Up to 2500 feet (762 m) with 200 devices: 51 ci Total Wire Length Allowed With "1" Taps for Cass B Wiring; up to 10,000 ft (3 km) Total Capacitance Allowed jo.& pF (600 nF) Annunciator Communications Quantity Supported Up to four annunciator modules per panel (see page 4 for deta/s) Wiring Size and Type See description for Uniscan wiring above Wiring Distances Bus-Style Wiring Up to 4000 ft (1219 m); 0.58 pF'580 nF) maximum capacitance: 35 ci max. Up to 10.000 ft (3048 m) total wiring; up to 2500 ft 762 m) to farthest device "T-Tap" Wiring Line Matching Resistor Bus-Style Wiring Connect one at panel and one at end of line 100 ci. 1/2W: TEPG-US T-Tap Wiring Connect one at panel and one at farthest device T301-901 i Suppression Use TEPG-US 1301-0001 Overvoltage Protectors where wiring leaves and enters a building (refer to data sheet 1301-10) Option Module Ratings Three Relay Auxiliary Contact Ratings I 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Module ADT6008RL - - - Wiring Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) Environmental Ratings - Operating T 32" to 120"F (0" to 49" C) Operating H Range Up to 93°I RH, non-conde 100.4" F (38" C) maximum 5 AD16008-01 Rev 11/2005 Supervisory and Alarm Currents Co Model Module Supervisory Alarm ADT-6008 Standard fire alarm control panel with 50. 175 mA 200 mA Uniscan devices ADT-6008A Control panel with 24 LED Annunciator 193 mA + 1 mA per Uniscan 250 mA+ 1 mA per Uniscan device device ADT-6008PS Expansion Power Supply 50 mA 60 mA ADT-6008RL Expansion Relay Module 10 mA per energized relay 10 mA per energized relay ADT-6006CTY City Circuit Module with disconnect switch 30 mA 60 mA ADT•6006CTYD City Circuit Module without disconnect 30 mA 60 mA switch ADT-2000 Remote LED/Switch Annunciator 40 mA . 70 mA maximum (see data sheet ADT2000-01 for details) (all LEDs and tone-alert on) ADT-2001 Remote LCD Annunciator 100 mA 150 mA (see data sheet ADT2001-01 for details) Current Calculation information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. Addressable Device Information The following addressable device types and hardware point types are provided. A combination of autoprogram, and either front panel or PC programming allows the operation to be selected per application. Available Fire Detection Device Types Device Description Photoelectric Addressable Uniscan operation: standard Detector sensitivity = 2.5%/ft Fixed temperature thermal Heat Addressable Detector detection of 135 F (572 C) Addressable Hardware Point Types Options Sounder base (selectable for single station I With communications isolator With relay output Selectable for 3.5%/ft Sounder base (selectable for single station With communications isolator With relay output Individually selectable to add rate-of-rise heat detection of 15 F/minute (8.3 C/minute) Function Type FIRE Description Fire monitor device Function Type WFS Description Combination waterfiow and water supervisory device WATER Waterfiow monitor device SUPV Supervisory monitor HEAT Heat detector device UTIL Supervised utility monitor DUCT Duct detector device TROUBLE Trouble monitor PULL Manual (pull) station device VERIF Verified fire alarm; an alarm level causes the alarm verification cycle to start SMOKE Smoke detector device STYLEC I Style C fire monitor SO Sprinkler Supervisory LATSUPV Latching supervisory monitor (supervisory latches until system is reset) ---- -- 6 A0T6008-01 Rev 3 11/2005 Co Co IMPNOMMI M., 77M The following relay operations are selectable from either the front panel or the PC programmer. Common Fire Alarm Operations Function Type Relay Activates Upon OTS General Alarm Relay Deactivates Upon Silence OTR General Alarm Reset SUPV Supervisory condition Clear TROUBLE Trouble condition Acknowledged Special Functions Function Type UTILITY Description Utility input in the same alarm group activates PRIMARY General alarm: relay is tied to Primary Elevator Recall contacts ALTERN General alarm: relay is tied to Alternate Elevator Recall contacts DRESET Relay provides 24 VDC power to 4-wire detectors: relay turns off for 5 seconds on System Reset DHOLDER Relay provides 24 VDC to larger door holder relay with separate power source; relay activates on general alarm to remove power to door holder relay and dose doors [Additional Programming Feature Details Function Details I Up to 20 characters per point; a built-in message library provides for commonly used words for easy front Custom labels panel programming For front panel label creation convenience, the following words can be selected as part of a custom label [_designates a built-in space; typing the first letter of a word/number will select the closest word in alphabetical/numerical sequence] Message Library North Center Flr3 Floor Basement Lobby I main Boiler_RM Elevator I South rear Flr_4 Garage Office I first Classroom Entrance Restroom I Storeroom East 5t h Flr_5 Hallway Patient I 2nd Closet Wing West Fir_i RM HVAC Room upper I 3rd Corridor Room I Zone Front Flr_2 lower I 4th Kitchen Elect RM Stairway I Three separate logs: Alarm (100 entries), Supervisory (100 entries), and Trouble (300 entries); logs can be History logs queried separately, or as a combined log; logs can be downloaded for printing or archiving using the RS-232 service port Automatically scans system for installed option modules and configures panel programming accordingly; Autoprogram modes are available to detect new modules only, recreate default programming and then add all modules found; Scans of addressable loop adds addressable devices, displays total added; checks for duplicate addresses and identifies errors Alarm Groups Up to 99 alarm groups are available, any point may be in up to 3 alarm groups; this allows NAC and relay operation to be associated with inputs according to local response requirements Walktest Allows one person to perform system testing: alarm or trouble tests are followed by automatic reset; the alarm zone is sounded Out by associated audible notification or the response is silently logged into the Alarm log Manual Control Allows selection of individual relays or NACs for system testing Level 1 = Acknowledge, Silence, System Reset, View logs, View point information, and Lamp Test Passcode Protection Level 2 = All Level I + Set Time/Date, Point Control, Enable/Disable points (4-digit number) Level 3 = All Level 2 + Clear logs, Clear verification tallies, Custom label editing, and Walktest Level 4 = All Level 3 + Programming, Upload/Download: this is the Service access level 7 A016008-01 Rev 11/2005 C Box width 15-5/8" (397 mm) 10uts are (Top and side views are shown with door installed) located on top and sid 0 00 0 J Box depth = 4-1/4" (108 mm) standard 4-5/8" (117 mm) w/annunciator door 4 11 - 1 /4" (286 mm) (main boa rd _______ 1 L __ LI,Iul1tI10 —ø - ha __ 5/8" (16 mm) _______ I 16" Door thickness 13-1/2" Display IJIXD I ( Expansion ___ t1]DJ (343 mm) A55flblY OtD ______ (406 mm) {Power Supply*j Mai board ________ @c±nPut Terminals) rCity Module' I I aL Expansion ute*j conduit or wiring in this a FN.rea Battery Area Relay Mod - I I — -2 * 13-1/4"(337 mm) NOTE: For semi-flush mounting, cabinet Indicates optional modules must extend 1-112" (38 mm) minimum from wall surface IRED LEDI IDC I I 10 5 -1 ICC 9 IDC 2 L1 IDC 6 ItA IDC 10 LI IDC3 IDC7 IDC4 . IDC8 14 CUSTOM LABEL AREAS are available, typically for IDC and NAC annunciation (shown labeled for reference, blank (FOUR YELLOW LEDs provide labels are provided); dual LED locations have a Red LED default NAG Trouble annunciation (top) and a Yellow LED (bottom); labels insert into pockets (shown labeled as NAG 14) behind the overlay; LED operation is programmable to track other monitored status conditions Tyw, AOl, the AOl logo, Unlsicde, and the Ll*ncde logo are trademarks of Tyco Imemaknal ServkesAG or its sditlsres in the U.S. aed/ct other cctintnes. NFPA 72 and National Fire Alarm Code are reglstered trademarks of the Natimal Fie Protectice Association (NFPA). ADTSecurity Services, Inc., One Town Center Road ADT6008-01 Rev 3 11/2005 tijCO J'& Boca Raton, FL 33486 .5 2005 lyon Safety Produds Westrriwter and AN, Inc Al rights meseved. At spectitcatirams and other tefonratirer stwse, were cainent as of doo.ussenl revalon date and are sued to change without voice, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE COLISTING No. 7165-1574:195 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ 07004-1561 Contact: Ron Dalton *(310) 619-2342 FAX *(310) 619-2208 DESIGN: Models ADT-6006, ADT-6006A, ADT-6008, and ADT-6008A Commercial Fire Alarm Control Panels. Local, auxiliary, remote station, central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ADT-6006P5, ADT-6008PS Expansion Power Supply (EPS) ADT-CTYD, ADT-6006C1Y City Circuit Modules (CCM) ADT-6006AA Class A Adaptor (C LA) ADT-6006RL ADT-6008RL Relay Modules (ARM) ADT-60061DC Expansion Initiating Device Circuit (XIUM) ADT-3101 lDNet Signal Individual Adapter Module (Sigl) RATING: 120 v, 60 Hz, 2 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and 4 in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. XLF: 7165-0026:318 'Rev. 06-06-05 Tfl This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy It Program Manager tIJCO/Fire& ) 1 Security S UL, CSFM Listed; FM Approved, MEA (NYC) Acceptance* IBM 1ult* Provides additional notification appliance circuit (NAC) capacity: For use with ADT-6006 Series Unimodeth CL and ADT-6008 Series Unimode AE fire alarm control panels Four standard Class B output NACs are rated 2 A @ 24 VDC and provide output control for TEPG-US Two-Wire Horn/Strobe synchronized notification appliances (see details on page 2) Up to 4 NAC Extenders can be controlled from two dedicated NAC inputs; one for horns, one for strobes Internal power supply/battery charger: Rated 8 A total; charges sealed lead-acid batteries up to 12 Ali (typical) internally mounted, or up to 25 Ali batteries in external cabinet (see page 2 for details) Provides power-limited outputs and status monitoring of battery, input power, and earth faults NAC Extender Options: • Four additional Class B NACs, rated 1.5 A @ 24 VDC Class A Control Module for Two-Wire Horn/Strobe output (mounts external) Dual Circuit Class A Adapter Module (for Regulated 24 VDC appliances) • Optional external battery cabinet for up to 25 Ali UL Listed to Standard 864 irnrrrrrni ADA Compliance. Complying with the notification requirements of ADA (Americans with Disabilities Act) may require more notification appliance power than is available within the fire alarm control panel. When additional power is required, an ADT-3 50.1 NAC Extender can provide up to 8 A of NAC power with up to eight, supervised reverse polarity NACs. Location Flexibility. Mounting can be close to the host panel or remotely located for convenient power distribution. Additional Information. This document describes using the ADT-350 1 NAC Extender with an ADT-6006 or ADT-6008 control panel for control of TEPG-US Two-Wire Horn/Strobe notification appliances. The ADT-3501 does provide multiple operation modes; for additional information, refer to Installation Instructions 579-601. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Usting 7300-1574:135 for allowable values and/or conditions concerning material presented in this document. it is subied to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - 11 1111, This product was not ULC listed as of document revision date. UL listing is under file number S232. Additional listings may be applicable, contact your local AOl product supplier for the latest status. Fire Alarm Control Accessories ADT-3501, 8 A NAC Extender for ADT-6006 and ADT-6008 Fire Alarm Control Panels I I NAC Control I I ADT-6006 or ADT-6008 Fire Alarm Control Panel ADT-3501 NAC Extender Connection DdIJct Slctir Model I Description ADT-3501 I NAC Extender with 4 Class B NACs and 8 A power jsupply; 120 VAC, 60 Hz input; red cabinet Optional Modules (for on-site Installation) Model Description ADT-3551 Additional four point NAC module, rated I max 1.5A, Class B ADT-3552 Dual Class A adapter for Regulated I 4 max 24 VDC appliances (for two NAC outputs) Options (select per system requirements) Model I Description Red External Battery Cabinet for up to 25 Ah ADT-3601 batteries; dimensions= 16-114" W x 13-1/2" H x 5-3/4"D (413 mm x 343 mm x 146 mm) Control Module, required for Class A Two-Wire 1372-9802 Horn/Strobe control operation; refer to data sheet T372-02 for details 1309-9801 Red semi-flush trim kit; 1-7/16" (37 mm) wide T301-9008 10 kc3 End-of-line resistor for Class B NACs A013500-01 Rev 2 11/2005 S Input Voltage 3A @ 102-132 VAC, 60 Hz Conventional reverse polarity operation; input is on steady (non-coded), for Two-Wire Control NACs, Input Horn/Strobe control output 3 mA @ 24 VDC in Alarm (rated Requirements 4.5mA maximum 21.1 to 29.1 VDC) Maximum operating voltage is 18 to 32 VOC, filtered or unfiltered UL listed for sealed lead-acid batteries up to 25 Ah; series connected 12 VDC Battery Charger batteries must be matched (same Capacity; for model, and date code) Cabinet accepts (2)12 VDC batteries, 24 VDC battery system; typically (2) each sized up to 6" W x 4" D x 4" H 12 VDC batteries in (153 mm x 102 mm x 102 mm) series including terminals (typical of 12 Ah); check battery size before installation; use remote battery cabinet for larger batteries Remote Battery Cabinet size is 16-1/4" W x 13-1/2" H x Cabinet ADT-3601, 5-3/4" D (413 mm x 343 mm x 146 mm); for up to 25 Ah confirm battery fit before installation; batteries mounts close-nippled, 20 it (6 m) max. Output Ratings Total Output 8 A for Special Application Appliances 6 A for Regulated 24 VDC Appliances Auxiliary Output 500 mA @ 24 VDC nominal Standard NACs 2 A each @24 VDC nominal Optional NACs (requires ADT-3551) 1.5 A each @24 VDC nominal Compatible TEPG-US Special Application Notification Appliances (refer to Installation Instructions 579-601 for additional information) Type Model Number Data Sheet Horn 1371-9001 (red, wall mount) 1371-01 Strobes Mount Red White 1371-03 Wall 1371-9407 T371-9409 Ceiling T371-9408 1371-9410 Horn! Strobes Wall 1371-9304 T371-9308 T371-04 Ceiling 1371-9305 T371-9309 Speaker! Strobes Wall 1371-9306 T371-9310 T371-05 Ceng 1371-9307 -Special Application" and "Regulated 24 VDC" are designations per UL Standards 1971 and 864. For use with listed Regulated 24 VDC appliances, refer to manufacturer's information for compatibility and any required interface components. [NAC Extender Specifications NAC Input Selections. For use with the ADT-6006/6008 control panels, the ADT-3501 NAC Extender is connected per the following: Two input NACs are used, one to provide strobe control, including strobe synchronization signals; the other to provide horn control; both are to be on steady (non-coded) Output NACs track input NAC operation Input NACs can support connected appliances (Two-Wire Horn/Strobe control signals are not supported for input NACs) NAC output selections: Output NACs are selected for Two-Wire Horn/Strobe control to provides separate operation of horns and strobes on the same circuit See compatible TEPG-US Special Application appliance list under specifications to the right; speaker/strobe appliances have separate inputs and require an audio source such as the ADT-6003 Voice Control Panel (see data sheet ADT6003-01) Class A operation of this mode requires Control Module T372-9802, mounted external to cabinet Power-up Self-Diagnostics. Upon power-up, the NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are indicated at the host control panel and are also displayed on diagnostic status LEDs in the NAC Extender. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door Mounted Reference Label. The NAC Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. AC power status is indicated by a green LED that is on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble(s) will then be indicated until the NAC Extender is returned to normal operation. LED Status Indicators. Each NAC (standard and optional) has a dedicated yellow LED that: During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit During an alarm, the LED follows the NAC output (on steady or flashing with coded output) A0T3500-01 Rev 2 11/2005 To additional NAC Extenders (up to four (4), NAG Extenders per NAG) I I Four Glass B NAGs are standard, rated 2 A @ 24 VDC; option ADT-3551 provides four I additional NAGs rated 1.5 A @ 24 VDC ciinput ADT3501NAC (see note) Extender 1w 1111111 nH -E NAC2 input \ Class A wiring return (see n - - I Two-wire Synchronized Horn/Strobe Operation ADT-6006/ADT-6008 - Fire Alarm Control Panel T372-9802 Two-Wire Horn/Strobe Synchronization Control Module; required for Class A wiring; NOTE: For Two-Wire Horn/Strobe output mounts in 4" (102 mm) square electrical box, see NAG operation, (or separate audible Installation Instructions 579-649 for details and visible output NAG control), two (2) input NACs are required. NAG 1 is strobe control and operates as Optional ADT-3601 Remote Battery steady "on-until-reset and NAG 2 is Cabinet, mounts close-nippled to cabinet horn control and operates as steady "on-until-silenced." NAG Extender Mounting and Module Placement Information - - - L. Cabinet depth 4-1/4" (108 mm) 17 Door, 5/8" (16 mm) thick O\ 13-1/2" (343 mm) 16-1/4"(413mm) 10-29/32" (277 0 0 I'$*lI44'P 0 Semi-flush trim option 1-3/16" wide (30 mm), LL 3/8" (9.5 mm) thick Wall surface reference for semi-flush mount'" [Optional ADT-3552 Class A Adapter Modules J Sys iem Module) ADT-3551 Additional Four point module (shown with ADT-3552 Class A Adapters) 0 Exposed cabinet dimension for semi-flush mount 1" (25.4 mm), 1-3/8" (35 mm) with semi-flush trim ,. Non-power limited wiring area (AC input) - Knockouts for screw or nail mounting holes .itfl 12" (305 mm) Battery location, no conduit entry or wiring in —L this area (12.7 Ah battery outline shown) 0 01 NOTE: Recommended conduit entrance varies with module selection. Refer to installation instructions 579-601, specific module installation instructions, and to field wiring S diagrams 842-415 before locating conduit entrance. 3 ADT3500-01 Rev 2 11/2005 NAC Extender Current Chart = - Panel Module Selection (shaded model numbers are optional modules) Model Description Supervisory Current Actual Supervisory Alarm Current Actual Alarm ADT-3501 120 VAC input J Basic Panel 85 mA 85 mA 185 mA 185 mA ADT-3551 Additional Four Point NAC 40 mA + + NAC loads + NAC loads (add below) (add below) ADT-3552 Dual Class A Adapter (current - - - included in basic panel value) Auxiliary Power Output, calculate per total 500 mA 500 mA device requirements (see note 5) maximum + maximum (Al) + Total Supervisory Current = (A) + Total NAC Extender Panel Alarm Current = (BI) NAC Loads NAC Type NAC Circuit # NAC Alarm Current Circuit I + Standard Panel NACS, 2 A maximum per NAC (see note 5) Circuit 2 + Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1.5 A maximum per NAC (see note 5) Circuit 6 + Circuit + Circuit 8 + Total NAC Loads Alarm Current = I Total NAC Extender Panel Alarm Current (enter BI from above) = (B2) + Total Alarm Current = Procedure: Calculate total panel supervisory current (A). Calculate total panel alarm current (Bi) [convert mA to A, example: 350 mA = 0.35 A]. Copy (Bi) into block (B2). Calculate total NAC loads alarm current from notification appliance ratings (C). Add (C) + (B2) to determine total alarm current (D). Current (Al) + NAC Loads Alarm Tyco, ADT, the ADT logo, Urd mode, and the Unimode logo are trademarks of Tyco Intemalionet Services AG or its affiliates in the U.S. and/or other countries. ADT Security Services, Inc., One Town Center Road ADT3500-01 Rev 2 11/2005 ti/cu /rim Boca Raton, FL 33486 Soo ty © 2005 Tyco Safety Products Westminster and ADT, Im All "its reserved. All specifications and other infonnalion shown were current as of document revision date and are suect to change without notice. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 5 LISTING No. 7300-1574:135 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ 07004-1561 Contact: Ron Dalton *(310) 619-2342 FAX *(310) 619-2208 DESIGN: Model ADT-3501 Notification Appliance Circuit (NAC) Power Extender. Refer to listee's data sheet for detailed product description and operational considerations. Unit components: ADT-3551 NAC Option Card ADT-3552 Class A Adaptor INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a NAC power extender unit for use with listee's separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. S NOTE: For fire alarm use, the secondary (standby) power supply shall supply energy during power loss to operate a protected premises, central station, or proprietary system for 24 hours or an auxiUiary or remote station system for 60 hours in the normal condition followed by not less than 5 minutes of alarm as required by code. XLF: 7300-0026:214 Rev. 06-03-05 1I This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy 0 Program Manager ti.jC13 / Fire & Security Ce UL Listed; FM, CSFM, and MEA (NYC) Approved* Uniscan Analog Detection Uniscan Analog Addressable Detectors - Photoelectric, and Heat; Compatible Bases and Accessories 9 Uniscan analog detection provides digital transmission of analog addressable detector values via Uniscan two-wire communications** Fire alarm control panel provides: Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Automatic, once per minute individual detector calibration check that verifies detector integrity Automatic environmental compensation Ability to display and print detailed addressable detector information in plain English language Photoelectric smoke detectors: Two levels of sensitivity 2.5% and 3.7% Heat detectors: Fixed temperature detection Rate-of-rise temperature detection Utility temperature detection For use with: ADT-6008 Series addressable panels Magnetic test feature Functional and architecturally styled chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Optional accessories include remote LED alarm indicator and output relays UL listed to Standard 268 under file S232 This product has been approved by the California State Fe Marsh (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Listings 7272-1574:187 (smoke detector); 7300-1574:188 (bases); and 7270.1574:134 (heat detector) for aflcwdefe vstuea and/or conditions concerning material presented in the document. It is s1jb3ed to re-examination, revision, and possible cancePatiDn. Accepted for use - City of New York Depararmeof ri Buidings - MEA35-93E. This peodrevi was not ULC listed as of document revision date. Additional listings may be applicable; contact your local AOl product suppliers for the latest status. lJniscan addreeaabio detectors are protected by one Co one of the 1c8cwing U.S. Patenis 5,155,468; 5,173.683; 5,400,014; 5543,177; 5110,541; 0383,407: D388,35Z 0392,573 Uniscan addressable communications designs are protected by U.S Patent No. 4,796,025. ADT-3201 Photoelectric Addressable Detector Mounted in Base [Description Digital Communication of Analog detection. Uniscan analog addressable detectors provide an analog measurement that is digitally communicated to the host control panel using ADT addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the addressable detector's present value against its average value and time. Intelligent Data Evaluation. Monitoring each addressable detector's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Detector Alarm and Trouble LED Indication. Each addressable detector base's LED pulses to indicate communications with the panel. If the control panel determines that an addressable detector is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that addressable detector base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed addressable detectors. A0T3200-01 Rev. 2 7/2005 Uniscan Detector Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (dipswitch under addressable detector) Automatic identification provides default sensitivity when substituting addressable detector types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design Magnetically operated functional test Mounts on standard outlet box I 'ITJ:yi-i*i ADT-3206, Standard Addressable Detector Base ADT-3207, Addressable Detector Base with wired connections for: ADT-3301 Remote LED alarm indicator or ADT-3 302 relay (unsupervised) ADT-3208, Detector Base with supervised relay driver output: Relay operation is programmable and can be manually operated from control panel Use with remote mount ADT-3304 relay Also includes wired connections for remote LED alarm indicator or ADT-3302 relay ( Eir ADT-3304, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A ® 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) ADT-3302, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @28 VDC non-power limited rating of 1/2 A @ 120 VAC. (requires external 24 VDC coil power) 1360-9850, Adapter plate: Required for surface or semi-tiush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product ADT-3301, Remote red LED Alarm Indicator: H Mounts on single gang box (shown in illustration to right) H ' scrintic Uniscan addressable detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat detectors. Each addressable detector's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since Uniscan addressable detectors use the same base, different detector types can be easily interchanged to meet specific location requirements. This feature also allows intentional detector substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke detectors (causing them to be disabled), heat detectors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect detector type, the heat detector will operate at a default sensitivity providing heat detection for building protection at that location. Ivtuunhlr1y rceterence Electrical Box Requirements: (boxes are by others) Without celaz 4' octagonal or 4' square. 1-12' deep: single gang. 2' deep 4' octagonal or 4" square, 1-1/2' deep, with 1-1/2' extension ring 4 (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference -- 1-1(2' (35 mm) minimum box depth Flush mount reference mount even with foal surface, or with up to 14' (6.4 mmi maximum recess ------------------------------------------------- ADT.3304 Relay 1m0u0t5 in AOT.302 Relay (mounts base electrical box or remotely) in base electrical box) Relay Size: 2-12'X 1.1 2' X ("(375 cubic inches) 64 mm 38 mmX 25.4 mm) NOTE: Review total sire count, '.:ire size, and accesaodes being wired to determine required box :clume. ------------------------------------------------- 6-318'(i62mm) T360-9850 Adapter Plate metired for mounting 10 mo(jn'eu boxes 8.4 mm) 4-7,8",' 124 mm) 15;i6" 24 mm) C Uniscan Gases AOT-3207. 3208. & 3206 A0T3200-01 Rev, 2 7/2005 Co C. Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Addressable Heat Detectors: Selectable rate compensated, fixed temperature detection with or without rate-of-rise operation Spacing distance between addressable 135° F (57.2° C) heat detectors: UL Spacing 1M Spacing 60 ft 15 ft x 15 ft (4.6 m) fixed temperature only (18.3 m) 30 ft x 30 ft (9.2 m) fixed temperature with rate-of-rise Addressable Smoke Detectors: Photodlectric technology detection 3600 smoke entry for optimum response DT-3203 Haf fltete Uniscan addressable heat detectors are self-restoring and provide rate compensated, fixed temperature detection, selectable with or without rate-of-rise temperature detection. Due to its small thermal mass, the addressable detector accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is individually selectable at the control pane! for 15° F (8.3° C) per minute. Fixed temperature detection is independent of rate-of-rise detection and operates at 135° F (57.2° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. I... 4-7/8' (124 mm) T LED status indicator 2-3/8' (60 mm) 1W Uniscan addressable photoelectric detectors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke detection. Sensitivity is monitored and selected at the fire alarm control panel. Standard sensitivity is 2.5% per foot of obscuration. If required, the ADT-6008 fire alarm control panel can select all addressable smoke detectors to operate at 3.7% per foot of smoke obscuration. The addressable detector head design provides 360° smoke entry for optimum response to smoke from any direction. A built-in screen keeps insects from entering the smoke chamber. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. -4-7/8'(124 mm) J LED status indicator 2-1/& (54 mm) ADT-3201 Photoelectric Addressable Detector with Base Addressable detector locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Codé. On smooth ceilings, smoke addressable detector spacing of 30 ft (9.1 in) may be used as a guide. ADT-3203 Heat Addressable Detector with Base rWARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. 4 A0T3200-01 Rev. 2 7/2005 Uniscan Analog detectionIProductiSelectionz.m Uniscan Addressable Detector Bases* Model Description Compatibility Mounting Requirements ADT-3206 Standard Addressable Detector Detectors ADT-3201 and -3203 4" octagonal 0r4" square box, 1-1/2" mm. Base, no options depth; or single gang box, 2" mm. depth Addressable Detector Base with Detectors ADT-3201 and -3203 ADT-3207 connections for Remote LED Alarm Indicator or ADT-3301 remote LED alarm indicator or Unsupervised Relay ADT-3302 relay 4" octagonal or 4" square box Note: Box depth requirements depend Addressable Detector Base with Detectors ADT-3201. and ADT-3203 connections for Supervised on tal wire count and wire size, refer to accessories list below for reference. ADT-3304 remote relay (supervised) ADT-3208 Remote Relay and connections for Remote Alarm indicator or AOT-330 1 remote alarm indicator or Unsupervised Relay ADT-3302 relay (unsupervised) Uniscan Addressable Detectors Model Description Compatibility Mounting Requirements ADT-3201 Addressable Photoelectric Bases ADT-3206, -3207, and -3208. Other I Smoke Detector compatible bases are -3210 isolator and Refer to base requirements ADT-3203 Addressable Heat Detector sounder bases. Refer to data sheet A0T3200-05 for further information. I Uniscan Addressable DetectorlBase Accessories Model Description Comoatibllltv Mauntfne Reoulrements I Remote Mounting requires 4" octagonal or ADT-3304 Supervised Relay, mounts remote or For use with AOT-3208 base 4" square box, 1-1/2" minimum depth in base electrical box Base Mounting requires 4" octagonal box, 2-1/8" deep with 1-1/2" extension ring ADT-3301 Remote Red LED Alarm Indicator on Single gang box, 1-1/2" minimum depth single gang stainless steel plate Bases ADT-3207 and ADT-3208 Relay, tracks base LED status ADT-3302 (unsupervised, mounts only in base 4" octagonal box, 2-1/8" deep with 1-1/2" electrical box) extension ring Required for surface or semi-flush T360-9850 Adapter Plate Bases AOT-3206, -3207. and -3208 mounted 4" square box and for surface I mounted 4" octagonal box * Refer to data sheet A013200-05 for Sounder Base and Isolator Base information. Specifications General Operating Specifications Communications and Addressable Detector Supervisory Power Uniscan, auto-select. 24-40 VDC 'N/data, 400 j.LA typical. 1 address per base Communications Connections Screw terminals for iniout wiring. 18 to 14 AWG (0.82 mm" to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0. 82 mm2 UL Listed Temperature Range 32" to 100' F (0' to 38" C) Operating with ADT-3203 Temperature Range with ADT-3201 32' to 122" F (0' to 50' C) 15" to 122" F -9" to 50" C) Humidity Range 10 to 95% RH Addressable Smoke Detector Ambient Rating Air velocity = 0-2000f1,'min (0-610 rn/mm) Housing Color Frost White ADT-3208 Base With Supervised Remote Relay ADT-3304 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 pA, from 24 VDC supply Alarm Current with ADT-3304 Relay 28 mA, from 24 VDC supply ADT-3302 Unsupervised Relay, Requirements for Bases ADT-3207. and ADT-3208 (see page 2 for contact ratings) Externally Supplied Relay Colt Voitage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from commun;cations Alarm Current 13 mA from separate 24 VDC supply lym, AOT, and the ADT lcgo are trademarks of T'ym lntematnal Semices AG or its affiliates .he U.S. a,dlcw other r.ocnlotes NFPA 72 and National Ewe iarm Code are registered trademarks of theNational Fire Protection Assixiatira (NFPA). ADTSecurity Services, Inc., One Town Center Road A0T3200-01 Rev. 2 7/2005 (40 tqca F,r'& Boca Raton, FL 33486 D 200 Tym Safety fkoduds Weslrrinsirr and ADI. Inc /4 qgtft reserved. /4 spei*atices and other inforrretiort shoai oem oaotnt as of dotaimerit revision We and are sLtoct Is change Aflasjt notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1574:187 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ 07004-1561 Contact: Ron Dalton *(310) 619-2342 FAX *(310) 619-2208 DESIGN: Models ADT-3201and ADT-3202 analog photoelectric type smoke detectors. Units are intended for use with Model ADT-3206, -3207, -3208, or -3209 (CSFM Listing No. 7300- 1574:188) smoke detector bases. Model ADT-3201 is listed for use with Model ADT-3204 (CSFM 3240-1574:191) duct detector units. Model ADT-3202 employs an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0026:218 Rev. 06-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2005 Listing Expires June 30, 2006 ( Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1574:134 Page 1 of 1 CATEGORY: Heat Detector LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ 07004-1561 Contact: Ron Dalton *(310) 619-2342 FAX *(310) 619-2208 DESIGN: Model ADT-3203 electric combination rate compensated, fixed temperature, and rate of rise heat detector. Unit intended for use with Simplex Models 4098-9789, -9791 or —9792 detector bases (CSFM Listing No. 7300-0026:217). Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION MARKING: APPROVAL: XLF: 135°F and 155°F In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, temperature ratings, and UL label. Listed as a heat detector for use with separately listed Simplex 4100, 4010, 4020 and 4120 series fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7270-0026:216 Rev. 06-06-05 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2005 Authorized By: DIANE K. A REND, Senior Deputy 0 Program Manager Listing Expires June 30, 2006 tqca / Fire & c Security UL CSFM Listed; FM Approved; MEA (NYC) Acceptance* ADT-6008 Uniscan Addressable Devices ADT-3102 Supervised Monitor Module Uniscan addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from module to supervision resistor(s) of up to 500 ft (152 m) For use with the following ADT control panels: ADT-6008 and ADT-6008A Unimode 46 AE fire alarm control panels Model ADT-3102: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Uniscan communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked UL listed to Standard 864 strintit Individual addressable monitor modules receive both power and communications from a two-wire Uniscan circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of- line resistor. Model ADT-3102 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. ADT3100-01 Rev 1 11/2005 ADT-3102 0 IMSI INSIR DATE CODE,REV M 1tllU All. CKT5 ADT-3102 Supervised Monitor Module (shown full size) flnpritinn Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status. iirrmt I imifprl Onrtinn Annlieatinns Dual Function Monitoring. ADT-3102 Supervised Monitor Modules can sense normal, open circuit, short circuit, and current limited conditions. With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. This çzahst has been approved by the California State Fe Marshal (CSFM) pursuant to Sec&zl 13144.1 of the California Health and Safety Code, See CSFM Listing 7300-1574:189 for atkevaise Values aroilor conditions concerning material presented in this dcxsimecit it is astee to re-exan*tation, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA 2-05-E. This product was not ULC listed as of Ikajmerit redsinn date. UL listing is Larder ite number S232. Additional listings may be alicae, contact your local ADT product supplier for the latest status. Lfoinir addressable non,najrrcations designs are protected by U.S. Patent No. 4,796, ff25. Zone Module Product Selection 14 Model Number Description ADT-3 102 Supervised Monitor Module, mounted in thermoplastic housing with screw terminals; see applicable options below ADT-3112 Module Cover, flush mount, single gang with LED cutout (galvanized) Requires 1301-9805 ADT-31 13 Module Cover, surface mount, single gang with LED cutout (galvanized) Mounting Bracket T301-9805 Mounting Bracket for Supervised Monitor Module T301-9004 Resistor Harness, 6.8 k, 1/2 W I I See applications in Specifications below; 1301-9003 Resistor Harness, 4.7 1/2 W I Refer to data sheet 1301-11 for details T301-9005 Resistor Harness, 1.8 ki), 1/2W 14 F Specifications Electrical Power and Communications Uniscan, auto selected, 1 address per Zone Module Input Requirements Normally open, dry contacts Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Supervision Resistor Harness, standard 6.8ki), 1/2W; 1301-9004 operation NOTE: Refer to installation instructions 579-611 and field wiring diagram 743-365 Resistor Harness for Current Limited 1.8 ki), 112 W; T301-9005 for additional information. 4.7 K, 1/2 W; T301-9003 Operation (one each) Wiring Distances Distance from Module to Contacts Wiring Distance Reference per channel, Uniscan Communications Mechanical 500 ft (152 m) maximum without protectors 400 ft (122m) maximum with 1301-0001 Overvoltage Protectors Max distance (18 AWG) is 2500 ft with more than 125 devices. Max distance is 4000 ft with less than 125 devices. 10,000 ft maximum wiring load with 1-Taps (based on 18 AWG TSP, 29 pF/ft). Dimensions 1-9/16" W x 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) Housing Material Black thermoplastic Temperature Range 32° to 120°F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) (S 2 ADT3100-01 Rev 1112005 © II L © Light pipe for LED viewing 4-1/4W (108 mm) [Mounting Information C' ADT-3102 Uniscan N 4_ Field wiring shown supervised module for reference LED viewing port ADT DOT-3O2 SIPERVEO ( ) MONITOR POI.AD --NST ASTR.579.611 REV DATE COL M ALL CATS a Single gang electrical box 2-1/2 (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) 4 Mounting Reference, Single Gang Blank Cover Plate 2-1/2 (64 mm) ADT-3 112, Trim plate for semi-flush mounted box __________2-1311&_______ 4 (72 al mm) AOT-31 13, Trim plate for surface mounted box T301-9805, Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket T301-9805. Optional Trim Plates and Mounting Bracket for Visible LED (S 3 ADT3100-01 Rev 1 11/2005 14 14 Tyco, ADT, teADT logo, and 1*irtode are lradefTcis of Tyco Intumfional SeivicesAG or as attfIeswi the U.S andky other cotjntñes. - ADTSecwiIy Services, Inc., One Town Center Road ADT3100-0I Rev. 1 1112005 tqcu Coca Raton, FL 33486 52005 Tyco Safety Poducls Wesminsr and ACT, nc. At nghts arsaved. All s €d1cicns and cther ick*ma&e slce.i eeia c&jnest as dccumarfl redce date and are v2eO to c5aoge without not. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1574:189 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ 07004-1561 Contact: Ron Dalton *(310) 619-2342 FAX *(310) 619-2208 DESIGN: Models ADT-3102 Supervised IAM Monitor Module; ADT-3103 [AM Relay Module; ADT- 3106 Class "A" ZAM Initiating Module; and ADT-3105 Class UB ZAM Initiating Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC 30 VDC for Model ADT-3103 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. ( APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0026:223 Rev. 06-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2005 Listing Expires June 30, 2006 ( Authorized By: DIANE K. AREND, Senior Deputy 0 Program Manager ADT-3401 Addressable Manual Station (front and side view) ADT-3402 Push Dortic Activation of the ADT-3401 single manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Double Action Stations (Push Type) ADT-3402 require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action Station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarni switch. (If the break-rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. tllcl3: Fire & Security • , UL, CSFM Listed; FM Approved; MEA (NYC) Acceptance* ADT-6008 Uniscan Addressable Devices Addressable Manual Stations I ttt[t*U Individually addressable manual fire alarm stations with: Power and data supplied via Uniscan addressable communications using a single wire pair** Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (push) operation UL listed to Standard 38 Compatible with ADT-6008 Series Unimode® AE fire alarm control panels Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as ADT fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes flpqrintinn The ADT-3401 addressable manual station and ADT-3402 push station combines a conventional manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral module constantly monitors status and communicates changes to the connected control panel via Uniscan communications wiring. 'This product has been approved by the California Slate Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Lislg 7150-1574:190 for allowable values and/or conditions concem4 material presented in this document. It is sect to re-esansnatiori, revision, and possible cancellation. Accepted for use - City of New York Department of Btaldkis - MEA 2-05-E. This prcriuct was not ULC listed as of document revision date. UL listing is under fie number S232. Additionai tstings may be vpçlicdete, contact your lest ACT product supplier for the latest status. Uniscan addressable ciarmssiioaitces designs are protected by U.S. Patent No. 4,796,025. A0T3400-01 Rev 1 11/20005 [Aidressable Manual Station Product Selection Addressable Manual Stations Model ADT-340 1 ADT-3402 Accessories Description Single action Addressable manual station, red housing with white Double action, Push operation letters and white pull lever Model T361-9202 T361-9201 T361-9807 1361-9808 1361-9803 1361-9804 1361-9802 Description Surface mount steel box, red Cast aluminum surface mount box, red Semi-flush trim plate for double gang switch box, red Surface trim plate for Wiremold box V5744-2, red Flush mount adapter kit, black Flush mount adapter kit, beige Replacement break-rod Reference Refer to page 3 for dimensions Typically for retrofit, refer to page 4 Refer to page 4 for details 4 j[Specifications Power and Communications Uniscan, 1 address per station, up to 2500 ft (762 m) from fire alarm control panel, up to 10,000 ft (3048 m) total wiring distance (including T-Taps) Address Means Dipswitch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexane polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5"H x 3-314"W x 1"D (127 mm x 95 mm x 25 mm) Addressable Manual Station Semi-Flush Mounting Single Gang Box Mount Single gang box, 2-1/2° deep (64 mm), RACO#500 or equal (supplied by others) (0 FIRE ''LALARM I PULL DOWN 4" Square Box Mount 4" (102 mm) square box, 2-1/8' (54 mm) minimum depth, RACO #231 or equal (supplied by others) 7m ' 0 0 Mount flush or with 1, 1116"(2 mm) -..q- ___ maximum extension -"-----''--- 1 ° DO NOT RECESS / 4' Square box 0 / - with cover plate Station + side view Single gang cover plate, 3/4" - (19 mm) extension, RACO 8773 or -qua! (upped by others) I Single gang Wall surface box outline Semi-Flush Mount Side View 2 A0T3400-01 Rev 1 11/20005 r Surface Mount Side View with Internal Detail 1-1I4 Field wiring (shown for reference) T361-9202 box (shown for reference) Station cover hinges open for installation access I Switch wiring (prewired) lAddressable Manual Stations Surface Mounting là Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. T361-9202 Box 5 3/16.H x 4W x 2 3/16W 0 (132 mm x 102 mm x 56 mm) (ordered separately) Knockouts located top and bottom 1361-9201 Cast Box 5Hx3718Wx23/16D (127 mm x 98 mm x 56 mm) (ordered separately) Oil 10 PULL DOWN Access for 3/4 threaded conduit located top and bottom (12L L [-1 H 1 (25.4 mm) 3 3I4 (95 mm) Addressable Manual Station Address setting under esealab(e label (accessible with cover open) It! -iii. I Refer to NFPA 72, the Nuional Fire Alarm Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. Mounting shall be with the operable part not less than 3-1/2 ft (1.1 m) and not more than 4-1/2 ft (1.37 in) above floor level. At least one station shall be provided on each floor. Additional stations shall he provided to obtain a travel distance not more than 200 ft (61 in) to the nearest station rrom any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. A0T3400-01 Rev 1 11/20005 (0 3 Addressable Manual Station, Additional Mounting Information 4AM For retrofit and new i nstallations, additional compatible mounting boxes and the required adapter plates 1361.9808 Surface trim are shown in the illustration to for Wemold box 5-1/8" I-I x 5 W the right. (130 mm x 127 mm) Wiremold receptacle box model V5744-2 (supplied by others) CD )) Two gang switch box, each 3"Hx2Wx2-3/4"D (76 mm x 51 mm x 70 mm) (supplied by others) ADT-3401 Urescan . addressable station 1361-9807 Semi-flush trim for 2 gang switch box, 8" H x 4-1/2" W -i (152 mm x114 mm) Addressable Manual Station, Flush Mounting Information IFILrah mount adapter kit T361-9803, Black T361-9804, Beige\ LI Box must be recessed into wail 1" to 1-1/8 (25.4 mm to 29 mm) - - l;-777w __.r_•----- r - L: . "- (203 mm) Hole cutoutmustea minimum of 6" H by 5"W 152mmby127mm) LMW - Waif 43/4 (121 mm) .- surface 6-3/4" (171 mm) 4-11/16" (119 mm) square box 2-1,8' (54 mm) minimum depth (by others) Front View Side View Tyw, ADTS the ACT logo, and lintisode are trademarks of lyon eteniafenal Se,*es AG or its altitiates ii tire iS. andlorodiercoustries. NFPA 72 arid Nalkeid Fire Alarm Code are registered rademailts of the National Fire Protection Association INFPA(. Lease tea tradenrerir of the General Elecirk Company. Wwenxld a iraderiarti or the Wirenreid Cc4rpany. AorSecurity Services, Inc., One Town Center Road A0T3400-01 Rev 1 11/2005 tXcU O& /3ocaRaton, FL 33486 r)2005 lyon Safety Products Westminster and P,DT, . All rights reserved. At specifications and ctff sticaw were rural as of docasiant revialos date and as sut4ec1 to dssige ththonl mike. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1574:190 Page 1 of 1 CATEGORY: Manual Pull Stations LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ 07004-1561 Contact: Ron Dalton *(310) 619-2342 FAX *(310) 619-2208 DESIGN: Models ADT-3401 and ADT-3402 non-coded addressable manual pull stations. Model ADT- 3.401 is a single action station. Model ADT-3402 includes a push bar which must be punched in before being able to grab and pull down the actuating handle. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. XLF: 7150-0026:224 Rev. 06-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued JUNE 6, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager TEPG-US Multi-Candela Notification Appliances UL, CSFM Listed; FM Approved; Visible Notification Appliances with MEA (NYC) Acceptance' Horn and Synchronized Flash I 'Ttiit:;: Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a Two-Wire Horn/Strobe control circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit** "On-until-silenced" and "on-until-reset" operation on the same two-wire pair Horn control that can be selected to be temporal coded, march time coded, or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B (Style Y) operation requires connection to a compatible NAC or to Two-Wire horn/strobe Control Module 1372-9802 Class A (Style Z) operation when connected to the T372-9802 or to compatible fire alarm control panel NAC Wall mount ANs features: a T-: .;#• FIRE - Wall and Ceiling Mount A/Vs rl Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich output sound suitable for either coded or steady operation UL listed to Standard 464 - Tiss areiuul has been approved by the Cwilcwres Slate Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM L1S1119 7125-0597:126 for allowable values and/or conrktterat ccncenirig material presented in his document. It is subiect to re-era,rlsa&rn, revision, and Possible cancellation, Accepted for use - City of New York 0epartvestt of BuIdirs - MEA 324-03-E. Additional listings may be ar.çIke; cenlad your TEPG-US prorkicl supplier for the latest status, -- Contact your local TEPG-US equipment supplier for compatible the alarm control panels and related products. Two-wire hcrrdstrobe operation is protected by U.S. patent No. 5,281,789. Multi-Candela A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount A/V housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is detennined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to he seen at the side of the strobe lens. 1371-04 Rev 1 11/2005 Strobe Application Selection Proper selection of visible notification is dependent on C S occupancy, location, local codes, and proper applications of- the National Fire Alarm Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). i Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). Two-Wire Horn/Strobe operation mode provides this function using a single circuit (two-wire operation). ISvnthrnnized Strohs Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs or to Model T372-9802 Two-Wire Horn/Strobe Control Modules. Contact your local TEPG-US product supplier for additional information about these and other related products, and for information about compatible fire alarm control panels and NAC extenders. Product Selection Multi-Candela A/Vs Model Mounting Housing Color "FIRE" Lettering I Description 1371-9304 Red White I 1371-9308 Wall Horn with Multi-Candela Strobe; strobe intensity selectable White Red as: 15, 30, 75, or 110 candela; synchronized flash rate; 1371-9305 Ceiling Red White Two-Wire horn/strobe control required I White Red T371-9309 Wall Mount AN Adapters Model I Description Dimensions 1372-9801 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D 1372-9807 White deep surface mounted boxes (136 mm x 133 mm x 41 mm) j_depth with strobe = 4-3/8" (111 mm) Synchronization Control Module (refer to data sheet 1372-02 for additional information) Model Description Dimensions 1372-9802 4" x 4-1/8" x 1-1/4" 0 Two-Wire Control Module (installs in 4' square box) (102 mm x 105 mm x 32 mm) 01 1371.04 Rev 1 11/2005 0 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others 0 0 ,1 Wiring access hole a Wiring terminals Removable cover (toot required) IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly I _,..-Electrical above bottom r box outline of compatible - boxes NFPA 72 requires 80' (2.03 m) that the entire tens minimum be not less than 80' and not greater than 96" above the finished floor 4 T371-04 Rev 1 11/2005 Mounting Holes: 4 square (4) Single gang (2) Double gang (3) 3 Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing: factory setting is 15 cd Strobe intensity viewing slot Co íó Wall Mount or Ceilina Mount. Common Specifications Rated Voltage Range Regulated 24 VOC; see Note 1 below FIash Rate and Synchronized MAC Loading 1 Hz: with up to 35 synchronized strobes maximum per NAC Environmental: Temperature and Humidity 32' to 122' F (0' to 50 C); 10% to 93%. non-condensing at 100" F 138' C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 331 mm2); two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VOC 24 VDC 33 VDC Sound Type (see Note 2) Steady I Coded Steady Coded Steady I Coded Horn Output Ratings @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA UL 464 Test 88 dBA 84 dBA 90 dBA I 86 dBA Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-118 H x 5"W x 2-314"D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd Mount 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VOC at other voltages 24 VOC 70 mA 101 mA 184 mA 243 mA 60 mA 84 mA 143 mA 185 mA Housing Dimensions (with lens) 4-3/4 L' x 6-7/8" W x 2-5/8' 0(121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 ad 30 cd 75 cd 110 cd Mount 86 mA 132 mA 250 mA 320 mA Reference RMS Currents. 18 VOC at other voltages 24 VDC 8t mA 119 mA 216 mA 283 mA 70 mA 97 mA 167 mA 217 mA NOTES: Regulated 24 VOC" refers to the voltage range of 16 to 33 VOC per UL Standard 1971 Signaling Devices for the Hearing Impaired, changes effective May 1 2004. This voltage range Is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that Is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or March Time coded pulse and with a sound level meter reading on a"fast" setting. Under the same test conditions, coded horn output peak" sound level readings are typically 4 dBA higher. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) [installation Reference, Surface or Semi-Flush Mounting Ceiling Mount AN Installation Reference, Flush Mount Box Co ---- ----------------------- Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd ---------------------------- nd View [Wall Mount Installation Reference with Optional Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt Surface mount cotw box shown for 4' (102 mm) square box profile, 1-1/2 (38mm)deep AN `7 Surface mount adapter skirt: 1372-9801, Red; 1372-9807, White (conduit knockouts on all four sides) Ti , o is ii ire ls'nudrks s/ Tic-i, /nternwiy,nal AG ,,, its /Ji1iaIc, in the US. mi/tsr other cnuniries-VFP4 72 anti Nat/sinai Fire Al-m (ntis' ,p rs',,'Lsis-r,',I Thki,-1Th irks- ,,/ the .V,,tivn,s1 Fire Prolet-lion 4esot-iot/on (,/FPA). ~46 J'EPGUS ryco Safety Products Westrninster• Westminster, MA •01441-0001 USA T371-04 Rev 1 11/2005 www.tycosafetyproducts-usa-wm.com 2005 7',,, &cas' Pn,,Juns Wesrzninster.Allrighzs rcvc'rvsri. 11/.s-pa-/iratisns anti ,,ther u/oflm2J7On mho,tn 55k55? ,uflv,d as ,,fthxw,,enj inns,,, Ave, and ore suhjn-t to c/iaiige With, na notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE C OLISTING No. 7125-1597:126 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: TEPG - US, 91 Technology Drive, Westminster, MA 01441 -0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 1371-9304, T371-9308 wall mount and Models T371-9305 and 1371-9309 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority'having jurisdiction. For indoor use only. MARKING: Listees name, model number, electrical/candela rating, and UL label. ,- APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing ( • impaired when used with listee's separately listed fire alarm control units. All models require the use of Model T372-9802(CSFM Listing No. 7125-1597:122) sync control module. Refer to listee's Installation Instruction Manual for details. XLF: 7125-0026:317 01-12-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed This listing should not be used to verify correct operational requirements or installation L11 criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy (I* Program Manager S S fl" TEPG-US UL, CSFM Listed, FM Approved; MEA (NYC) Acceptance* I1titi. Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: UL listed to Standard 1971 Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: NACs from fire alarm control panels or NAC extenders with compatible strobe synchronization or with compatible Two-Wire horn/strobe control** Separate Two-Wire horn/strobe Control Module 1372-9802 that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0597:127 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings.- MEA 324-03-E. Additional listings may be applicable; contact your TEPG-US product supplier for the latest status. Contact your local ThPG-US equipment supplier for compatible tire alarm control panels and related products. Two-wire strobe synchronization operation is protected by U.S. patent No. 5559492. Two-wire horn/strobe operation is protected by U.S. patent No. 6281789. Multi-Candela Notification Appliances Visible Notification Appliances with Synchronized Flash Wall Mount Strobes Ceiling Mount Strobes IP1-4(.4ll1rn1 Multi-Candela synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. be Intnnsitv Snlnctic During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. F117, Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). T371-03 Rev 1 11/2005 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs or to Model T372-9802 Two-Wire Horn/Strobe Control Modules. rTm1rn1Irn[.1l11TlrI Contact your local TEPG-US product supplier for additional information about these and other related products, and for information about compatible fire alarm control panels and NAC extenders. rrrAIrr1: M, M. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). Two-Wire Horn/Strobe operation mode provides this function using a single circuit (two-wire operation). Product Selection Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description T371-9407 Red White T371-9409 Wall White Red Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; T371-9408 Red White Two-Wire horn/strobe control compatible 1371-9410 Ceiling White Red Wall Mount Strobe Adapters Model Description Dimensions T372-9801 Red Surface Mount Adapter Skirt; use to cover 1-1/2" 5-3/8" H x 5-1/4" W x 1-5/8" 0 1372-9807 White (38 mm) deep surface mounted boxes (136 mm 133 mmx4l mm) Total depth with strobe = 4-3/8" (111 mm) Synchronization Control Module (refer to data sheet 1372-02 for additional information) Model Description Dimensions 1372-9802 Two-Wire Control Module (installs in 4" square box) 4"x4-1/8"x1-1/4"D (102 mm x 105 mm x 32 mm) 2 T371-O3 Rev 1 11/2005 C Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC: see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd Mount 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 55 mA 85 mA 169 mA 226 mA 41 mA 63 mA 123 mA 164 mA Housing Dimensions (with lens) 4-3/4" L x 2-5/16" W x 2-5/8' D (121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd Mount 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 64 mA 102 mA 199 mA 266 mA 49 mA 76 mA 146 mA 195 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with single gang, double gang, and 4"(102 mm) square boxes, 1-1/2° (38 mm) deep, by others III Wiring access hole _ 4J Wiring terminals Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; 15 [F I] [ [ factory setting is 15 cd S Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r _—Electrical above bottoms r box outline of compatible boxes I — 7 NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80° and not greater than 96° above the finished floor T371-03 Rev 1 11/2005 Ceiling Mount Strobe Installation Reference For flush mounting, use single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal); or mount a 000 handy box, 1-1/2" (38 mm) deep (RACO 650 or equal) using a drop ceiling T-bar with clips (ERICO No. 512 or equal); boxes and hardware supplied by others For surface mounting, use Wiremold V57S, 2-1/4" (57 mm) deep (or equal), supplied by others 11 FR E /f_- Ceiling mount strobe - ------------------------- Strobe intensity I viewing slot Intensity selection plug, accessible only from rear of lens: housing; L-- Wall Mount Installation Reference with Surface Mount Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt Surface mount conduit and box shown for reference 4"(102 mm) square —._.. - I box profile, 1-1/2" I (38 mm) deep Strobe - Surface mount adapter skirt: T372-9801, Red; T372-9807, White (conduit knockouts on all four sides) Tyco is trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). TEPG (IS Tyco Safety Products Westminster. Westminster, MA 01441-0001 USA 1371-03 Rev 1 11/2005 www.tycosafetyproducts-usa-wm.com © 2005 Tyco Safety Products Westminster. All rights reserved. Afispec/fications and other information shown were current as ofdocument revision date and are subject to change without notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1597:127 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: TEPG-US, 91 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models T371-9407, -9408, -9409, and -9410 multi-candela, non-addressable, synchronizable strobe lights. Models T371-9407 and —9409 are for wall mount. Models T371-9408 and —9410 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. XLF: 7125-0026:316 01-18-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy [] Program Manager