HomeMy WebLinkAbout3622 GARFIELD ST; ; FPR2020-0093; PermitJ ski II:11Is]:i 4 '(L'~'C- ity o f Carlsbad Print Date: 10/06/2020 Job Address: 3622 GARFIELD ST, CARLSBAD, CA 92008-8218 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2042401601 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: GARFIELD CONDOS -NEW SPRINKLER MONITORING SYSTEM Permit No: FPR2020-0093 Status: Closed - Finaled Multifamily Fire Alarm Applied: 08/31/2020 Issued: 09/14/2020 Finaled Close Out: 10/06/2020 Inspector: Final Inspection: Applicant: FPContractor: SYMONS FIRE PROTECTION INC SYMONS FIRE PROTECTION INC MICHAEL GULINO 12155 PAINE PL 12155 PAINE PL POWAY, CA 92064-7154 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 760-602-8561 f I www.carlsbadca.gov Ff\2-OW-- OO° W FZ ES R, CD NJ S I \f E • FZ E S CD Li IR C E F LI L • F2 IE LI . L Fire Alarm System Complete Material Submittal Prepared for: ., Garfield Trmimplex Three Unit Condominiums 3622 Garfield Street Carlsbad, CA 92008 August 25th, 2020 12155 Paine Place • Poway, CA 92064 • (619) 588-6364 • Fax (619) 588-6805 • CA Lic. #682025 TABLE OF CONTENTS - FIRE ALARM SYSTEM SUBMITTAL 1. FIRE ALARM SYSTEM EQUIPMENT AND DEVICES: SILENT KNIGHT - FIRE ALARM SYSTEM CONVENTIONAL PANEL - 5208 TELGUARD - CELLULAR ALARM COMMUNICATOR - TG7-FS SPACE AGE - FIRE ALARM DOCUMENT CABINET - ACE- li INTERSTATE - 12 V / 7Ah - SEALED LEAD ACID BATTERIES - SLA-0124 SILENT KNIGHT— FIRE ALARM SYSTEM MANUAL PULL STATION - PS-SA SYSTEM SENSOR - FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR - 2W-B S S 12155 Paine Place 4 Poway, CA 92064 ' (619) 588-6364 Fax (619) 588-6805 CA Lic. #682025 S D SILENT KNIGHT by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones Supervised zone expanders and I/O modules can be mounted remotely from the main control panel Event History Buffer (150 events) with date/time stamp All zones are compatible with 2- or 4-wire detectors 8 selectable/programmable output patterns for notification appliance circuits Built-in Digital Alarm Communicator Transmitter (DACT) 4 Notification Appliance Circuits 4 programmable general purpose relays Programmable smoke verification, pre-alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms Programmable from the built-in control panel touchpad, remote annunciator, or Windows® SKSS downloading software Direct connect port for on-site up/downloading with Windows® SKSS downloading software Built-in walk test feature Single or dual interlock water releasing capability Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Programmable AC trouble relay Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® Programmable date settings for Daylight Saving Time Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @60Hz, 2A Total DC Load: 6Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16(8.73cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 10 - 93% noncondensing Optional Accessories SK-5235 LCD Remote Annunciator SK-5217 10 Zone Expander (2 max. per system) SK-5280 Status Display Module (8 max. per system) 5220 Direct Connect Module 5824 Serial/Parallel Printer Interface Module SKSS Downloading Software SK-5208 Plex-2 Door Option SK-SCK Seismic Compliance Kit Listings and Approvals UL Listed CSFM Listed MEA approval 429-92-E Vol. XIII OSHPD (CA) OSP-0065-10 Model 5208 Fire Alarm Control Panel with Digital Communicator S Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line I Telephone Line 2 2 Class A (Style D) or Class B (Style B Initiation Circuits 8 Class B (Style B) Initiation Circuits 4. Direct Connect For On-Site Programming Programmable Form C Relays Notification Appliance Circuits .'I]15235 Remote + J Annunciators SBUS Devices 5280, 5217, & 5824 S This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, by Honeywell Fax: (203) 484-7118. For Technical support, Please call 800-446-6444. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-0559:0137 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Model SK-5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterfiow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: SK5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 10/5/2017 Interstate Batteries Detail Sealed Lead Acid Page - 12V 7AH SLA FR 187 FASTON Customer Service 866-842-5368 41 Recycling HOME HOME & WORK & LIGH11NG & HEALTH & BATTERIES BY VEHICLE ACCESSORIES MY ACCOUNT TTERIES ELECTRONICS GARAGE OFFICE SECURITY MEDICAL TYPE BATTERIES —Store Locator Home >> Sealed Lead Acid! SLA >> 11.0-13.0 Volts >> 7.0000>> The Genesis SLA0124 battery is constructed for maximum power and capacity. Original equipment quality and performance assured. Common applications include emergency light, security alarms, medical equipment and more. This battery is non- spillable and maintenance free. See the Also Fits tab for a list of applications. Your Price: $36.99 List Price: $46.99 INTERSTATE BATTERIES Customer Service Live Chat )) M-F 8am-5pm CST , Email Customer Service )) Call Toll Free: 866-842-5368 M-F 8am-5pm CST Need a custom battery?a THE INTERSTATE BATTERIES Guarantee We want you to be completely satisfied with every battery you purchase from Interstate Batteries.com. If you are not completely satisfied with an item that you purchased, you may return most items within 45 days of delivery for a full refund of the purchase price, minus the shipping charges. For exceptions, please refer to Warranty Exclusions and Return Exclusions. Specifications F F ] F I Reviews Also Fits] FBest Uses Warranty Features/Benefits Product ID: SLAO 124 Milliamp Hours: 0 Voltage: 12 Termination: .187' FASTON SPADES Chemistry: SEALED LEAD ACID Color: GRAY Weight (Ibs): 5.71 Width (in): 2.5600 Length (in): 5.95 Height (in): 3.94 V IELP ABOUT BATTERIES CORPORATE OUR BUSINESS ustomer Service I Safety Data Sheets(SDS) About Us Locations ite Map FAQ Career Center All Battery Centers rivacy Policy Battery Terms News & Press I Distributorships hipping Policy Recycling Racing PowerCare onditions of Use Warranty Team Member All Battery Class Action Settlement ©2017 Interstate Batteries 1/2 10/5/2017 Interstate Batteries Detail Sealed Lead Acid Page - 12V 7AH SLA FR 187 FASTON S S 2/2 S I ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1hdeep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information 9 RGERED NFPA COMPANY IWEIV Made InU.S.A. Space Age Electronics, Inc. 2009 ED0549 LT1 0559 Rev.D 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. S Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector Pmperty Information Minimum Required Dovon,nnto6on(SIG.FUN) CertIfIcatIons and Approvals 16.1 Sir._IflAlalletion ThA 5Y0 .5 sonar 0,55 ,.s tee, k.,5kd 5,0 sr.soaacavcns000eonaoraau, 4sgr.n,snr,0rc.ne,cvvnspesvt. v,.r.c..tnv P,ktanrre. ___________ ecopn,00ths,sra,ancs 16.5 Authority Heanp Jonadiolion: == ==tem,nac nFtetena,d.Cedn.,0, v.d,edasp.aot.,000,5j,.or,se,.navn tto752 PM.dr.v.. race,ye.or,0v,avy.svO,vnd.,0.ts.ntv.,ors2 ttcvnostawlcwtena.tt.,,.pAatA Eqolprnnnt Information rtn.tnal.5-orslostcn. 1010544 0.5.1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsae.com . 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED 55U00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFXID enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. I I 02-09-16 dc TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division TELGUARD ) TG - 7FS CELLULAR ALARM COMMUNICATOR LTE-A FOR LTE NEIWORKS P/N TG7LAF01 I ó COMMERCIAL FIRE PRODUCT FEATURES I.. Certified for use on the AT&T LTE network for long, sunset-free installation. I Meets UL 864 requirements for sole, primary or backup path communications. I Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. 5 -...-...- •'t' . 5••_ TG-7FS CELLULAR ALARM LTE -A FOR LTE NETWORKS TELG UARD (t t) Alinm Panel LTE-A C LndI,r,o (Opt,o,,al> Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 • control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telguarct.com. SECURITY SIGNALING 4;~ ( LJ® IEAEC N LISTED E NEPA /It\ Executive Strategic Partner Connected '-t.._.___._.P INTERNATIONAL Gold byAT&T Telguard, a Division of Telular corporation • 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 • www.Telguard.com copyright 2017 Telular corporation • All Rights Reserved o:oi7P,B n S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION [In a OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA001, TG7LAA0I, TG7LA002, TG7LAF01, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF0I, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 6 ~~ SYSTEM $ SENSOR® Photoelectric Smoke Detectors System Sensor j3" series smoke detectors represer significant advancement in conventional detecti The I family is founded on three principles: instaL I ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & LISTED <i~> 0 MEA MSFM approved approved AN . S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base.The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. I (j.) Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor j3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2W7-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4VVT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2VVT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal InputTerminals 14to22AWG Mounting LED Modes 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model TThermal '/flh,t. Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/ maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter aS}'STEA#'7 SENSOR 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2. Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4W1-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2W1-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 C 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires August 29, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S D KNIGHT SILENT by Honeywell PS-DA and PS-SA Conventional Pull-stations Easy to Install and Operate The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock I reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS- DA and PS-SA simple to install, maintain, and operate. Operation The single-action pull-station is activated by a single pull-down of the alarm handle. The dual-action versions require pushing in the handle, then pulling the handle down for activation. The PS- DA/PS-SA manual pull stations are UL listed and meet the ADA requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. Molded terminal numbers can be found adjacent to the wiring termi- nals. Models: PS-SA— Single action with 'pigtail' connections and a key lock reset. Pigtail wires are provided for con- nection to the Fire Alarm Control Panel's (FACP) initiation circuit. PS-DA - Dual action model with screw terminal connections and a key lock reset. PS-DAH - Same as PS-DA except with hex lock reset. PS-DALOB - Same as PS-DA with "outdoor use" listing. Includes SB- I/O backbox and sealing gasket. PS-DASP - Same as PS-DA except with both English and Spanish operating instructions. PS-DA Features: UL Listed CSFM Listed Meets ADA requirements Operating instructions are mold- ed into the handle along with Braille text. Made of durable Lexan Available in Spanish Key resettable Easy to Install and operate Single or dual action Surface mount box available D ,LLt:N KNIGH F PS-DASP Specification: Dimensions: Height: 5-1/2" (13.97 cm) Width: 4" (10.16 cm) Depth: 1-7/16" (3.65 cm) Operating temperature 32°F to 120°F (0°C to 49°C) Electrical: Switch contact Rating: 0.25A@ 30 VAC orVDc Accessories: SB-I/O Surface Mount Back-box BG-TR Trim Ring PS-DA and PS-SA Conventional Pull-Stations Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back-box SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO" on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View 13SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are sub- P/N 350241 Rev. D ject to change without notice. For more information, contact Silent Knight 12 © 2011 Honeywell International Inc. by Honeywell Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0140 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models PS-SA, PS-DA, PS-DASP and IDP-PULL-DA fire alarm pull boxes. The PS series followed by SA or DA is a single action or dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 S *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2019 Listing Expires August 29, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division