Loading...
HomeMy WebLinkAbout5807 VAN ALLEN WAY; ; FPC2020-0043; PermitPERMIT REPORT 4'(Lr~'C- ity o f Carlsbad Print Date: 05/11/2021 Job Address: 5807 VAN ALLEN WAY, CARLSBAD, CA 92008-7309 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121200100 Track #: Valuation: $5,271,170.96 Lot #: Occupancy Group: Project #: DEV2017-0169 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0043 Status: Closed - Finaled Applied: 03/12/2020 Issued: 06/10/2020 Finaled Close Out: 05/11/2021 Inspector: Final Inspection: Project Title: SMAC Description: SMAC - NEW SPRINKLER SYSTEM, 2 RISERS, 613 HEADS (NEW CONSTRUCTION, SINGLE STORY) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTEMS INC DARIEN MORAN 249 E EMERSON AVE 13142 NELSON ORANGE, CA 92865-3304 CARLSBAD, CA (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $858.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $204.00 FIRE Protection Sys Manual $237.00 Total Fees: $1,299.00 Total Payments To Date: $1,299.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov V//VALLEY (JOIST. DECK 255 LOGAN LANE 775-575-7337 PHONE FERNLEY, NV 89408 775-5754917 FAX May 27, 2020 Minshew Bros. Steel Construction, Inc. Attn.: Mr. Nick Burley 23689 Vigilante Road Lakeside, CA 92050 Subject: SMAC Shell Building, Carlsbad, CA Our Job No. 9F01600 Joist Design for Fire Protection Piping Dear Mr. Burley, The joist design for the subject project includes the load effects for the 4" diameter and larger fire protection piping as shown on Pacific Fire Systems, Inc. drawings dated 0 1-02-20. Yours truly, Walter F. Worthley, Jr., PE Chief Engineer Valley Joist LLC cc: File Page 1 of 1 ci V VALLEY 255 LOGAN LANE 775-575-7337 PHONEfjf FERNLEY, NV 89408 775-575-4917 FAX f 30IST+DECK MAY 11, 2020 ENGINEERING REPORT COVER SHEET IS FOR FINAL CALCULATIONS (REV. 0) FOR APPROVAL BY ENGINEER OF RECORD RE: SMAC SHELL BLDG LOT 75 5801 VAN ALLEN WAY CARLSBAD, CA VALLEY JOIST CONTRACT NO.: 9F0 1600 CUSTOMER: MINSHEW BROS. STEEL CONST., INC. 12578 VIGILANTE ROAD LAKESIDE, CA 92040 THIS ENGINEERING REPORT SIGNATURE PAGE IS PROVIDED FOR JOIST AND JOIST GIRDER MARKS as shown on: SEQUENCE CALCULATION PAGES 9F01600-BLU 1-52 9F0 1600-BLU-LS 1-24 9F0 1600-RED 1-52 The joist and Joist Girder mark numbers are as shown on the Placement Plans. The calculations are based on all bridging in place and anchored as required by the SM Specifications & Technical Digests. The joist and Joist-Girder designations and special loads were determined and specified by the Engineer of Record, not by the steel joist manufacturer. The steel joist manufacturer's scope is limited to the design of the members in the steel joists. Their scope does not include the complete structure, structural connections, or the coordination of the components. The Professional Engineer's Seal affixed hereto indicates that the steel joists were designed in accordance with The Steel Joist Institute's Standard Specifications to support the loads specified, furnished and approved by the Owner's Engineer of Record. The seal is not intended to certify or imply that the building does or does not conform to any national, state or local building codes. Valley Joist is a certified, active member of the Steel Joist Institute. The steel angle shapes and round bars used for the chords and webs are 50-ksi minimum yield strength per the SM Specifications. The joist and Joist Girder material sizes were designed to carry as shown on the calculations, Valley Joist's ICC-lAS Certificate Number is FA-363. Walter F. Worthley, Jr., PE CA #C64116 Chief Engineer tIF2 i Valley Joist Cr * Exp. No. VJCALC:9FO1600NC V// VALLEY (OIST+OECK 255 LOGAN LANE 775-575-7337 PHONE FERNLEY, NV 89408 775-575-4917 FAX MAY 11, 2020 CERTIFICATE OF COMPLIANCE MINSHEW BROS. STEEL CONST., INC. 12578 VIGILANTE ROAD LAKESIDE, CA 92040 REP: SMAC SHELL BLDG LOT 75 Valley Joist Job #:9F01600 This is to certify that the joists and accessories furnished on the above referenced project are manufactured according to the information provided on the contract drawing. Valley Joist, Inc. Fernley, Nevada, a certified member of The Steel Joist Institute (SJI) and lAS Certified Fabricator, has manufactured the joists. Valley Joist's Quality Control Program has been reviewed and approved by the International Code Council (ICC) under the International Accreditation Service Certification number FA-363. The Quality Assurance Manual of Valley Joist has been reviewed and approved by the SM and lAS. Valley Joist certifies that all joists produced are 100 percent inspected per SM and JAS requirements and Valley Joist's Quality Assurance Manual. The quality assurance manual is available for your review on our premises, as are the inspection reports for the joists produced for the above project. Yours truly, Walter F. Worthley, Jr. Valley Joist West cc: Files ~~ O 2D -o0 43 - - - Fire Protection b, Computer Design Pacific Fire Systems, Inc 12316 Oak Knoll Road Suite A Poway, CA 92064 858-883-2333 Job Name : System #2.33/3000 overhead Building Location : Overhead System #2 System : 2 Contract Data File : sy52-33-3000.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PACIFIC FIRE SYSTEMS, INC. Page System #2 .33/3000 overhead Date 2/19/20 Hydraulic Design Information Sheet Name - SMAC Date - 02/26/20 Location - Overhead System #2 Building - System No. - 2 Contractor - Pacific Fire Systems, Inc. Contract No. - Calculated By - Pacific Fire Systems, Inc. Drawing No. - FP2/FP3 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - 20.5' Occupancy - B S (x) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 (X) Ex.Haz. Y NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other Figure 16.2.1.3.2 (c) Curve E T Specific Ruling Made By Date E M Area of Sprinkler Operation - 3000 System Type Sprinkler/Nozzle Density - .33 (x) Wet Make VIKING D Area Per Sprinkler - 96 ( ) Dry Model VK202 E Elevation at Highest Outlet - 20 ( ) Deluge Size 3/4" S Hose Allowance - Inside - ( ) Preaction K-Factor 8.0 I Rack Sprinkler Allowance - ( ) Other Temp . Rat . 286 G Hose Allowance - Outside - 500 N Note Calculation Flow Required - 1088.45 Press Required - 85.382 at BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 1/24/20 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 132 8 Press - R Residual Press - 108 Elev. - Well Flow - 4725 Proof Flow S Elevation - LEVEL U P Location - POC TO WATER MIAN IN VAN ALLEN WAY P L Source of Information - CITY OF CARLSBAD Y C Commodity Class III Location Warehouse O Storage Ht. 20' Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack N Single Row ( ) Conven. Pallet ( ) Auto. Storage C ) Encap. S R ( ) Double Row ( ) Slave Pallet C ) Solid Shelf ( ) Non T A C ) Mult. Row C ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Water Supply Curve C Pacific Fire Systems, Inc Page 2 System #2 .33/3000 overhead Date 2/19/20 City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 8.662 C2 - Residual Pressure: 97.2 D2 - System Flow :1088.45 C2 - Residual Flow : 4725 D2 - System Pressure :101.762 Hose ( Demand) : 500 D3 - System Demand :1588.45 Safety Margin : 14.164 150 140 - - 130 - Cl - P 120 : _______ R 110 - - D2 C2 E 100 - P ent I. er S90 - - ____ ____ s 80 U70 R6° E5° 40 30 20 ------ 10 Dl _ 500 1000 1500 2000 2500 3000 3500 4000 4500 FLOW( N"1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Pacific Fire Systems, Inc Page 3 System #2 .33/3000 overhead Date 2/19/20 Fitting Legend Abbrev. Name Y2 11/4 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zic Wilkins 350ADA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 L80O VSfl 'HN weqpui 1.1.1. 9flOJ OUI oeeJPAH Aq SWeJ6oJd ieTndwo3 CL 06 CEO PI.9C CL 06 CEO 9CEE CL 06 CEO 81CC CL 06 CEO 91CC CL 06 CEO 9VCC CL 06 CEO ETC CL 06 CEO 69CC CL 06 CCC 1717E OL 06 CEO 999E OL 96 CEO 817CE CL 96 CEO 903C CL 96 CEO 961C CL 96 CEO 961C CL 96 CCC 903E CL 96 CEO 17C3E CL 96 CCC 363C CL 96 CEO 68CC 0L 96 CCC i'EEE CL 96 CEO L61E CL 96 CEO 61C CL 96 CCC 6 I.E CL 96 CEO 86 I.E CL 96 EEC 933C CL 96 CEO C8ZE CL 96 CEO 6LEC CL 96 CCC 99U CL 96 CEO 8L1C CL 96 CEO 81.0 OL 96 CEO 961C OL 96 CEO 9CZC CL 96 CEO LEE CL 96 CEO 93PC OL 96 CEO 69C eu 89,917 L91.61. eu 179917 L91.61. eu I991 L91. 61. eu 9,917 L9V 61. eu I.8t'E L91 61. eu 9171C L9V61. BU ELEE L91.61. BU 179ZC L9I61. BU L61.0 L91.61. eu 381.E L91.61. eu 9991. L91.61. eu 8191. L91.61. eu 3EE1' L91.61. eu 69CP L91.61. eu 6179E 003 BU 639E 003 BU L8i'C 003 BU 1.I.PE 003 BU i'LOE 003 eu 81.OE ooz BU l.00 003 Bu L639 003 eu L609 003 eu 6361 003 eu L8LP 003 BU 9C171 003 BU E6E 003 eu 9 L1717 003 BU 1.8E17 003 BU 6391 003 BU EL9P 003 BU 9L917 003 eu C61. 8 003 BU 6CLI. 8 003 eu 3L I. 8 003 eu LVLI. 8 003 BU 8VLI. 8 003 eu EEL I. 8 003 eu CLLI. 8 003 BU 981. 8 003 BU 9(61. 8 003 Bu 1.9LI. 8 003 BU 9091 8 003 BU 9691. 8 003 eu 8691. 8 003 BU 9091. 8 003 eu 9E91. 8 003 BU P691. 8 003 Bu 961I. 8 003 eu LEL1. 8 003 BU L691. 8 003 eu 691. 8 003 BU 691. 8 003 BU 8691. 8 003 BU 9391. 8 003 BU P891. 8 003 Bu 1781 8 003 BU 8991. 8 003 BU 8(91. 8 003 BU 891. 8 003 eu 9691 8 003 BU 8 003 BU 3JJ. 8 003 BU 17C81. 8 003 BU 1403 8 003 IBflPV IBflPV ON SS3Jd B8J' AI!suea MOIJ Ud Id I3B.d-N UO!IBAOIJ WON 0Z16 I.IZ aa p83I4JAO 000C/CC- # W9SA 1, 96ej OUI 'SW91SAS OJd OLIPeçJ avavis - iciewwns M01J I ejnss9Jd Flow Summary - Standard Pacific Fire Systems, Inc Page 5 System #2 .33/3000 overhead Date 2/19/20 Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. M5 19.167 47.08 na M6 19.167 47.79 na M7 19.167 48.98 na M8 19.167 50.43 na M9 19.167 52.18 na M10 19.167 54.28 na Fl 19.167 69.76 na TOR2 19.167 74.79 na BOR2 3.0 85.28 na BOR1 3.0 85.38 na BOR 0.0 88.01 na UG1 0.0 88.26 na 500.0 UG2 0.0 92.01 na UG4 0.0 93.88 na UG5 0.0 100.19 na TEST 0.0 101.76 na The maximum velocity is 24.5 and it occurs in the pipe between nodes M10 and Fl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams F5acific Fke Systems, Inc Page 6 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 201 -179.61 2.157 0.0 8.000 20.140 K Factor = 8.00 to 120.0 0.0 0.0 0.0 202 -179.61 -0.2255 0.0 8.000 -1.804 Vet = 15.77 202 34.26 2.157 0.0 8.000 18.336 K Factor =8.00 to 120.0 0.0 0.0 0.0 203 -145.35 -0.1525 0.0 8.000 -1.220 Vel = 12.76 203 33.10 2.157 0.0 8.000 17.116 K Factor =8.00 to 120.0 0.0 0.0 0.0 204 -112.25 -0.0946 0.0 8.000 -0.757 Vet = 9.86 204 32.35 2.157 0.0 8.000 16.359 K Factor = 8.00 to 120.0 0.0 0.0 0.0 205 -79.9 -0.0504 0.0 8.000 -0.403 Vet = 7.02 205 31.96 2.157 0.0 8.000 15.956 K Factor =8.00 to 120.0 0.0 0.0 0.0 206 -47.94 -0.0196 0.0 8.000 -0.157 Vet = 4.21 206 31.80 2.157 0.0 8.000 15.799 K Factor =8.00 to 120.0 0.0 0.0 0.0 207 -16.14 -0.0026 0.0 8.000 -0.021 Vet = 1.42 207 31.78 2.157 T 12.307 5.000 15.778 K Factor =8.00 to 120.0 0.0 12.307 0.361 310 15.64 0.0025 0.0 17.307 0.043 Vet = 1.37 0.0 15.64 16.182 K Factor = 3.89 208 31.68 2.157 T 12.307 3.000 15.682 K Factor =8.00 to 120.0 0.0 12.307 0.361 310 31.68 0.0091 0.0 15.307 0.139 Vet = 2.78 0.0 31.68 16.182 K Factor = 7.88 209 -130.40 2.157 0.0 8.000 17.840 K Factor = 8.00 to 120.0 0.0 0.0 0.0 210 -130.4 -0.1248 0.0 8.000 -0.998 Vet= 11.45 210 32.83 2.157 0.0 8.000 16.842 K Factor =8.00 to 120.0 0.0 0.0 0.0 211 -97.57 -0.0729 0.0 8.000 -0.583 Vet = 8.57 211 32.26 2.157 0.0 8.000 16.259 K Factor =8.00 to 120.0 0.0 0.0 0.0 212 -65.31 -0.0348 0.0 8.000 -0.278 Vet = 5.73 212 31.98 2.157 0.0 8.000 15.981 K Factor =8.00 to 120.0 0.0 0.0 0.0 213 -33.33 -0.0100 0.0 8.000 -0.080 Vet = 2.93 213 31.90 2.157 0.0 8.000 15.901 K Factor =8.00 to 120.0 0.0 0.0 0.0 214 -1.43 -0.0001 0.0 8.000 -0.001 Vel= 0.13 214 31.90 2.157 0.0 8.000 15.900 K Factor =8.00 to 120.0 0.0 0.0 0.0 215 30.47 0.0085 0.0 8.000 0.068 Vet = 2.68 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 7 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 215 31.97 2.157 T 12.307 5.000 15.968 K Factor =8.00 to 120.0 0.0 12.307 0.361 311 62.44 0.0320 0.0 17.307 0.553 Vel = 5.48 0.0 62.44 16.882 KFactor= 15.20 216 -84.24 2.157 1 12.307 3.000 17.372 K Factor =8.00 to 120.0 0.0 12.307 0.361 311 -84.24 -0.0556 0.0 15.307 -0.851 Vel= 7.40 0.0 -84.24 16.882 K Factor = -20.50 217 -131.20 2.157 0.0 8.000 17.946 K Factor =8.00 to 120.0 0.0 0.0 0.0 218 -131.2 -0.1261 0.0 8.000 -1.009 Vel = 11.52 218 32.93 2.157 0.0 8.000 16.937 K Factor =8.00 to 120.0 0.0 0.0 0.0 219 -98.27 -0.0740 0.0 8.000 -0.592 Vet = 8.63 219 32.34 2.157 0.0 8.000 16.345 K Factor = 8.00 to 120.0 0.0 0.0 0.0 220 -65.93 -0.0352 0.0 8.000 -0.282 Vel = 5.79 220 32.06 2.157 0.0 8.000 16.063 K Factor =8.00 to 120.0 0.0 0.0 0.0 221 -33.87 -0.0104 0.0 8.000 -0.083 Vet = 2.97 221 31.99 2.157 0.0 8.000 15.980 K Factor =8.00 to 120.0 0.0 0.0 0.0 222 -1.88 0.0 0.0 8.000 0.0 Vel= 0.17 222 31.98 2.157 0.0 8.000 15.980 K Factor =8.00 to 120.0 0.0 0.0 0.0 223 30.1 0.0082 0.0 8.000 0.066 Vet = 2.64 223 32.04 2.157 T 12.307 5.000 '16.046 K Factor =8.00 to 120.0 0.0 12.307 8.662 312 62.14 0.0317 0.0 17.307 0.548 Vet = 5.46 0.0 62.14 25.256 KFactor= 12.36 224 -87.65 2.157 T 12.307 3.000 17.510 K Factor =8.00 to 120.0 0.0 12.307 8.662 312 -87.65 -0.0598 0.0 15.307 -0.916 Vel = 7.70 0.0 -87.65 25.256 K Factor = -17.44 225 -147.65 2.157 0.0 8.000 19.755 K Factor = 8.00 to 120.0 0.0 0.0 0.0 226 -147.65 -0.1570 0.0 8.000 -1.256 Vet = 12.96 226 34.41 2.157 0.0 8.000 18.499 K Factor =8.00 to 120.0 0.0 0.0 0.0 227 -113.24 -0.0961 0.0 8.000 -0.769 Vet = 9.94 227 33.68 2.157 0.0 8.000 17.730 K Factor = 8.00 to 120.0 0.0 0.0 0.0 228 -79.56 -0.0500 0.0 8.000 -0.400 Vet = 6.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 8 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 228 33.31 2.157 0.0 8.000 17.330 K Factor = 8.00 to 120.0 ' 0.0 0.0 0.0 229 46.25 -0.0182 0.0 8.000 -0.146 Vel = 4.06 229 33.16 2.157 0.0 8.000 17.184 K Factor =8.00 to 120.0 0.0 0.0 0.0 230 -13.09 -0.0018 0.0 8.000 -0.014 Vel = 1.15 230 33.15 2.157 0.0 8.000 17.170 K Factor =8.00 to 120.0 0.0 0.0 0.0 231 20.06 0.0039 0.0 8.000 0.031 Vet = 1.76 231 33.18 2.157 0.0 8.000 17.201 K Factor = 8.00 to 120.0 0.0 0.0 0.0 232 53.24 0.0238 0.0 8.000 0.190 Vet = 4.67 232 33.36 2.157 T 12.307 3.167 17.391 K Factor =8.00 to 120.0 0.0 12.307 8.662 313 86.6 0.0585 0.0 15.474 0.905 Vet = 7.60 0.0 86.60 26.958 K Factor= 16.68 233 -86.60 2.157 T 12.307 4.830 19.299 K Factor = 8.00 to 120.0 0.0 12.307 8.662 313 -86.6 -0.0585 0.0 17.137 -1.003 Vel = 7.60 0.0 -86.60 26.958 K Factor = -16.68 Ri -59.12 2.157 2T 24.613 63.000 45.759 to 120.0 0.0 24.613 0.361 300 -59.12 -0.0289 0.0 87.613 -2.530 Vel = 5.19 0.0 -59.12 43.590 K Factor = -8.95 R2 -62.18 2.157 2T 24.613 63.000 45.732 to 120.0 0.0 24.613 0.361 301 -62.18 -0.0317 0.0 87.613 -2.778 Vel = 5.46 0.0 -62.18 43.315 K Factor= -9.45 R3 -94.21 2.157 2T 24.613 63.000 45.285 to 120.0 0.0 24.613 0.0 302 -94.21 -0.0684 0.0 87.613 -5.990 Vet = 8.27 0.0 -94.21 39.295 K Factor = -15.03 R4 -164.19 2.157 T 12.307 99.000 43.811 to 120.0 4E 24.61,3 36.920 0.0 209 -164.19 -0.1911 0.0 135.920 -25.971 Vel = 14.42 0.0 -164.19 17.840 K Factor= -38.87 R5 -165.09 2.157 T 12.307 99.000 44.179 to 120.0 4E 24.613 36.920 0.0 217 -165.09 -0.1930 0.0 135.920 -26.233 Vel = 14.49 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 9 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -165.09 17.946 K Factor= -38.97 302 -215.51 2.157 4E 24.613 36.000 39.295 to 120.0 0.0 24.613 0.0 201 -215.51 -0.3160 0.0 60.613 -19.155 Vel = 18.92 0.0 -215.51 20.140 K Factor = -48.02 R6 -183.21 2.157 T 12.307 92.830 44.359 to 120.0 0.0 12.307 0.0 225 -183.21 -0.2340 0.0 105.137 -24.604 VeI= 16.09 0.0 -183.21 19.755 K Factor = -41.22 R7 -85.08 2.157 2T 24.613 218.420 47.873 to 120.0 0.0 24.613 0.0 R14 -85.08 -0.0566 0.0 243.033 -13.761 Vel = 7.47 0.0 -85.08 34.112 K Factor = -14.57 R8 -87.26 2.157 2T 24.613 218.420 49.288 to 120.0 0.0 24.613 0.0 R15 -87.26 -0.0593 0.0 243.033 -14.420 Vel = 7.66 0.0 -87.26 34.868 K Factor = -14.78 R9 -91.30 2.157 2T 24.613 218.420 50.973 to 120.0 0.0 24.613 0.0 R16 -91.3 -0.0645 0.0 243.033 -15.681 Vel = 8.02 0.0 -91.30 35.292 K Factor = -15.37 RiO -96.82 2.157 2T 24.613 218.420 52.972 to 120.0 0.0 24.613 0.0 R17 -96.82 -0.0719 0.0 243.033 -17.478 Vel = 8.50 0.0 -96.82 35.494 K Factor = -16.25 216 117.59 2.157 5E 30.767 80.500 17.372 to 120.0 T 12.307 43.074 0.0 R11 117.59 0.1030 0.0 123.574 12.732 VeI= 10.32 0.0 117.59 30.104 KFactor= 21.43 224 121.13 2.157 4E 24.613 79.500 17.510 to 120.0 T 12.307 36.920 0.0 R12 121.13 0.1088 0.0 116.420 12.672 VeI= 10.64 0.0 121.13 30.182 KFactor= 22.05 233 121.75 2.157 2T 24.613 79.500 19.299 to 120.0 0.0 24.613 0.0 R13 121.75 0.1099 0.0 104.113 11.439 VeI= 10.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Fcific Fire Systems, Inc Page 10 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 121.75 30.738 KFactor= 21.96 Ri 59.12 2.157 T 12.307 0.830 45.759 to 120.0 0.0 12.307 0.361 Ml 59.12 0.0288 0.0 13.137 0.379 Vel = 5.19 0.0 59.12 46.499 K Factor = 8.67 R2 62.18 2.157 T 12.307 0.830 45.732 to 120.0 0.0 12.307 0.361 M2 62.18 0.0317 0.0 13.137 0.416 Vel= 5.46 0.0 62.18 46.509 K Factor= 9.12 R3 94.21 2.157 T 12.307 0.830 45.285 to 120.0 0.0 12.307 0.361 M3 94.21 0.0684 0.0 13.137 0.898 Vel = 8.27 0.0 94.21 46.544 KFactor= 13.81 R4 164.19 2.157 T 12.307 0.830 43.811 to 120.0 0.0 12.307 0.361 M4 164.19 0.1911 0.0 13.137 2.510 VeI= 14.42 0.0 164.19 46.682 KFactor= 24.03 R5 165.09 2.157 T 12.307 0.830 44.179 to 120.0 0.0 12.307 0.361 M5 165.09 0.1930 0.0 13.137 2.536 Vel = 14.49 0.0 165.09 47.076 KFactor= 24.06 R6 183.21 2.157 T 12.307 0.830 44.359 to 120.0 0.0 12.307 0.361 M6 183.21 0.2340 0.0 13.137 3.074 Vel = 16.09 0.0 183.21 47.794 K Factor= 26.50 R7 85.08 2.157 T 12.307 0.830 47.873 to 120.0 0.0 12.307 0.361 M7 85.08 0.0566 0.0 13.137 0.743 VeI= 7.47 0.0 85.08 48.977 KFactor= 12.16 R8 87.26 2.157 T 12.307 0.830 49.288 to 120.0 0.0 12.307 0.361 M8 87.26 0.0594 0.0 13.137 0.780 Vel = 7.66 0.0 87.26 50.429 KFactor= 12.29 R9 91.30 2.157 T 12.307 0.830 50.973 to 120.0 0.0 12.307 0.361 M9 91.3 0.0645 0.0 13.137 0.847 Vel= 8.02 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Ffre Systems, Inc Page 11 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 91.30 52.181 K Factor = 12.64 RiO 96.82 2.157 T 12.307 0.830 52.972 to 120.0 0.0 12.307 0.361 M10 96.82 0.0719 0.0 13.137 0.944 Vel = 8.50 0.0 96.82 54.277 KFactor= 13.14 R11 117.59 2.157 1 12.307 0.830 30.104 to 120.0 0.0 12.307 0.361 Mil 117.59 0.1030 0.0 13.137 1.353 Vel= 10.32 0.0 117.59 31.818 KFactor= 20.85 R12 121.13 2.157 T 12.307 0.830 30.182 to 120.0 0.0 12.307 0.361 M12 121.13 0.1088 0.0 13.137 1.429 Vel= 10.64 0.0 121.13 31.972 KFactor= 21.42 R13 121.75 2.157 1 12.307 0.830 30.738 to 120.0 0.0 12.307 0.361 M13 121.75 0.1099 0.0 13.137 1.444 VeI= 10.69 0.0 121.75 32.543 KFactor= 21.34 R14 -85.08 2.157 T 12.307 0.830 34.112 to 120.0 0.0 12.307 0.361 M14 -85.08 -0.0566 0.0 13.137 -0.744 Vel = 7.47 0.0 -85.08 33.729 K Factor = -14.65 R15 -87.26 2.157 T 12.307 0.830 34.868 to 120.0 0.0 12.307 0.361 MiS -87.26 -0.0593 0.0 13.137 -0.779 Vel = 7.66 0.0 -87.26 34.450 K Factor = -14.87 R16 -91.30 2.157 T 12.307 0.830 35.292 to 120.0 0.0 12.307 0.361 M16 -91.3 -0.0645 0.0 13.137 -0.847 Vel = 8.02 0.0 -91.30 34.806 K Factor = -15.48 R17 -96.82 2.157 T 12.307 0.830 35.494 to 120.0 0.0 12.307 8.662 M17 -96.82 -0.0719 0.0 13.137 -0.945 Vel = 8.50 0.0 -96.82 43.211 K Factor = -14.73 300 -59.12 2.157 0.0 9.500 43.590 to 120.0 0.0 0.0 0.0 301 -59.12 -0.0289 0.0 9.500 -0.275 Vel = 5.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fife Systems, Inc Page 12 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 301 -62.18 2.157 4E 24.613 8.920 43.315 to 120.0 0.0 24.613 -0.361 302 -121.3 -0.1091 0.0 33.533 -3.659 Vel = 10.65 0.0 -121.30 39.295 K Factor = -19.35 310 47.32 2.157 4E 24.613 12.000 16.182 to 120.0 0.0 24.613 0.0 311 47.32 0.0191 0.0 36.613 0.700 Vet = 4.15 311 -21.81 2.157 0.0 12.000 16.882 to 120.0 0.0 0.0 8.301 312 25.51 0.0061 0.0 12.000 0.073 Vet = 2.24 0.0 25.51 25.256 K Factor = 5.08 Mil 117.59 3.26 0.0 11.167 31.818 to 120.0 0.0 0.0 0.0 M12 117.59 0.0138 0.0 11.167 0.154 VeI= 4.52 M12 121.12 3.26 0.0 11.167 31.972 to 120.0 0.0 0.0 0.0 M13 238.71 0.0511 0.0 11.167 0.571 Vet = 9.18 M13 121.75 3.26 0.0 10.830 32.543 to 120.0 0.0 0.0 0.0 M14 360.46 0.1095 0.0 10.830 1.186 Vet= 13.86 M14 -85.08 3.26 0.0 10.830 33.729 to 120.0 0.0 0.0 0.0 M15 275.38 0.0666 0.0 10.830 0.721 Vet = 10.58 M15 -87.26 3.26 0.0 10.830 34.450 to 120.0 0.0 0.0 0.0 M16 188.12 0.0329 0.0 10.830 0.356 Vet = 7.23 M16 -91.30 3.26 0.0 10.830 34.806 to 120.0 0.0 0.0 8.301 M17 96.82 0.0096 0.0 10.830 0.104 Vet = 3.72 0.0 96.82 43.211 KFactor= 14.73 Ml 59.12 4.26 0.0 9.500 46.499 to 120.0 0.0 0.0 0.0 M2 59.12 0.0011 0.0 9.500 0.010 Vet = 1.33 M2 62.18 4.26 0.0 8.920 46.509 to 120.0 0.0 0.0 0.0 M3 121.3 0.0039 0.0 8.920 0.035 Vel= 2.73 M3 94.21 4.26 0.0 12.000 46.544 to 120.0 0.0 0.0 0.0 M4 215.51 0.0115 0.0 12.000 0.138 Vel = 4.85 M4 164.19 4.26 0.0 12.000 46.682 to 120.0 0.0 0.0 0.0 M5 379.7 0.0328 0.0 12.000 0.394 Vet = 8.55 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 13 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn M5 165.09 4.26 0.0 11.250 47.076 to 120.0 0.0 0.0 0.0 M6 544.79 0.0638 0.0 11.250 0.718 Vel = 12.26 M6 183.21 4.26 0.0 10.830 47.794 to 120.0 0.0 0.0 0.0 M7 728.0 0.1092 0.0 10.830 1.183 Vel = 16.39 M7 85.08 4.26 0.0 10.830 48.977 to 120.0 0.0 0.0 0.0 M8 813.08 0.1341 0.0 10.830 1.452 Vel = 18.30 M8 87.25 4.26 0.0 10.830 50.429 to 120.0 0.0 0.0 0.0 M9 900.33 0.1618 0.0 10.830 1.752 Vel = 20.27 M9 91.31 4.26 0.0 10.830 52.181 to 120.0 0.0 0.0 0.0 M10 991.64 0.1935 0.0 10.830 2.096 Vel= 22.32 M10 96.81 4.26 2E 26.334 41.000 54.277 to 120.0 0.0 26.334 0.0 Fl 1088.45 0.2299 0.0 67.334 15.480 Vel = 24.50 0.0 1088.45 69.757 K Factor = 130.32 Fl 1088.45 6.357 2E 35.205 118.580 69.757 to 120.0 0.0 35.205 0.0 TOR2 1088.45 0.0327 0.0 153.785 5.033 Vel = 11.00 TOR2 0.0 6.357 B 12.573 16.167 74.790 to 120.0 5 40.235 90.528 7.002 BOR2 1088.45 0.0327 T 37.72 106.695 3.492 Vel = 11.00 BOR2 0.0 6.357 0.0 3.000 85.284 to 120.0 0.0 0.0 0.0 BOR1 1088.45 0.0327 0.0 3.000 0.098 Vel = 11.00 BORI 0.0 6.357 T 37.72 3.000 85.382 to 120.0 0.0 37.720 1.299 BOR 1088.45 0.0327 0.0 40.720 1.333 Vel = 11.00 BOR 0.0 8.27 E 28.468 7.000 88.014 to 140.0 0.0 28.468 0.0 UG1 1088.45 0.0068 0.0 35.468 0.242 Vel = 6.50 UG1 500.00 7.98 4E 108.73 78.000 88.256 Qa = 500 to 150.0 G 6.041 182.728 0.0 UG2 1588.45 0.0144 S 67.957 260.728 3.755 Vel = 10.19 UG2 0.0 7.98 T 52.855 77.000 92.011 to 150.0 0.0 52.855 0.0 UG4 1588.45 0.0144 0.0 129.855 1.870 Vel= 10.19 UG4 0.0 8.27 4E 113.872 15.000 93.881 to 140.0 Zic 0.0 113.872 4.540 * * Fixed Loss = 4.54 UG5 1588.45 0.0138 0.0 128.872 1.772 Vel= 9.49 UG5 0.0 7.98 T 52.855 50.000 100.193 to 150.0 G 6.041 58.895 0.0 TEST 1588.45 0.0144 0.0 108.895 1.569 Vel= 10.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fi?e Systems, Inc Page 14 System #2 .33/3000 overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 1588.45 101.762 K Factor = 157.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 --- Fire Protection by Computer Design Pacific Fire Systems, Inc 12316 Oak Knoll Road Suite A Poway, CA 92064 858-883-2333 Job Name : System #1 .33/3000 (Peaked) overhead Building Location Overhead System #1 (PEAKED) System : 1 Contract Data File : sysl-33-3000.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PACIFIC FIRE SYSTEMS, INC. System #1 .33/3000 (Peaked) overhead Page 1 Date 2/19/20 Hydraulic Design Information Sheet Name - SMAC Date - 02/26/20 Location - Overhead System #1 (PEAKED) Building - System No. - 1 Contractor - Pacific Fire Systems, Inc. Contract No. - Calculated By - Pacific Fire Systems, Inc. Drawing No. - FP2/FP3 Construction: C ) Combustible (X) Non-Combustible Ceiling Height - 20.5' Occupancy - B S Cx) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. C ) 1 ( ) 2 C ) 3 CX) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other Figure 16.2.1.3.2 (c) Curve E T Specific Ruling Made By Date E N Area of Sprinkler Operation - 3000 System Type Sprinkler/Nozzle Density - .33 (x) Wet Make VIKING D Area Per Sprinkler - 86.7 C ) Dry Model VK202 B Elevation at Highest Outlet - 20 C ) Deluge Size 3/4" S Hose Allowance - Inside - C ) Preaction K-Factor 8.0 I Rack Sprinkler Allowance - C ) Other Temp.Rat.286 G Hose Allowance - Outside - 500 N Note Calculation Flow Required - 1041.28 Press Required - 83.563 at BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 1/24/20 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 132 8 Press - R Residual Press - 108 Elev. - Well Flow - 4725 Proof Flow S Elevation - LEVEL U P Location - POC TO WATER MIAN IN VAN ALLEN WAY P L Source of Information - CITY OF CARLSBAD Y C Commodity Class III Location Warehouse O Storage Ht. 20' Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack N Single Row C ) Conven. Pallet C ) Auto. Storage ( ) Encap. S R C ) Double Row ( ) Slave Pallet C ) Solid Shelf C ) Non T A C ) Mult. Row C ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Water Supply Curve C Pacific Fire Systems, Inc Page 2 System #1 .33/3000 (Peaked) overhead Date 2/19/20 City Water Supply: Demand: Cl - Static Fressure : 118.8 Dl - Elevation : 8.662 C2 - Residual Pressure: 97.2 D2 - System Flow :1041.28- C2 - Residual Flow : 4725 D2 - System Pressure : 99.305 Hose ( Demand) : 500 D3 - System Demand :1541.28 Safety Margin : 16.776 150 140 130 Cl P 120 : R 110 - E 100 - OP r.iiu. kier S90 S 80 u 70 R6° E5° 40 -n 30 20 10 500 1000 1500 2000 2500 3000 3500 4000 4500 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Pacific Fire Systems, Inc Page 3 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Fitting Legend Abbrev. Name Y2 % 1 11/4 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zic Wilkins 350ADA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Paàific Fire' Systems, Inc Page 4 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Ri 20.0 35.01 na 101 20.0 8 13.97 na 102 20.0 8 13.31 na 103 20.0 8 12.96 na 104 20.0 8 12.81 na 105 20.0 8 12.79 na 106 20.0 8 12.8 na 107 20.0 8 12.91 na 108 20.0 8 13.22 na 109 20.0 8 13.81 na R2 20.0 35.07 na 110 20.0 8 14.05 na 111 20.0 8 13.4 na 112 20.0 8 13.05 na 113 20.0 8 12.91 na 114 20.0 8 12.88 na 115 20.0 8 12.9 na 116 20.0 8 13.01 na 117 20.0 8 13.33 na 118 20.0 8 13.92 na R3 20.0 35.26 na 119 20.0 8 14.36 na 120 20.0 8 13.72 na 121 20.0 8 13.38 na 122 20.0 8 13.24 na 123 20.0 8 13.22 na 124 20.0 8 13.24 na 125 20.0 8 13.37 na 126 20.0 8 13.71 na 127 20.0 8 14.35 na R4 20.0 35.82 na 128 20.0 8 16.05 na 129 20.0 8 15.51 na 130 20.0 8 15.26 na 131 20.0 8 15.19 na 132 20.0 8 15.19 na 133 20.0 8 15.26 na 134 20.0 8 15.52 na 135 20.0 8 16.06 na R5 20.0 37.22 na R6 20.0 38.04 na R7 20.0 39.06 na R8 20.0 40.34 na R9 20.0 42.11 na RiO 20.0 44.06 na Rll 20.0 15.94 na R12 20.0 16.09 na R13 20.0 16.64 na R14 20.0 18.15 na R15 20.0 22.77 na R18 20.0 29.4 na R19 20.0 29.74 na R20 20.0 30.04 na Mil 19.167 17.88 na M12 19.167 18.05 na M13 19.167 18.69 na M14 19.167 20.05 na M15 19.167 22.35 na M16 19.167 / 23.84 na M17 19.167 24.83 na M18 19.167 29.07 na M19 19.167 29.41 na Ml 19.167 37.09 na M2 19.167 37.14 na M3 19.167 37.33 na 29.9 0.33 86.7 7.0 29.19 0.33 86.7 7.0 28.8 0.33 86.7 7.0 28.64 0.33 86.7 7.0 28.61 0.33 86.7 7.0 28.62 0.33 86.7 7.0 28.75 0.33 86.7 7.0 29.09 0.33 86.7 7.0 29.73 0.33 86.7 7.0 29.99 0.33 86.7 7.0 29.29 0.33 86.7 7.0 28.9 0.33 86.7 7.0 28.74 0.33 86.7 7.0 28.72 0.33 86.7 7.0 28.73 0.33 86.7 7.0 28.86 0.33 86.7 7.0 29.2 0.33 86.7 7.0 29.85 0.33 86.7 7.0 30.32 0.33 86.7 7.0 29.63 0.33 86.7 7.0 29.26 0.33 86.7 7.0 29.11 0.33 86.7 7.0 29.09 0.33 86.7 7.0 29.11 0.33 86.7 7.0 29.25 0.33 86.7 7.0 29.62 0.33 86.7 7.0 30.3 0.33 86.7 7.0 32.05 0.33 86.7 7.0 31.51 0.33 86.7 7.0 31.25 0.33 86.7 7.0 31.18 0.33 86.7 7.0 31.18 0.33 86.7 7.0 31.25 0.33 86.7 7.0 31.51 0.33 86.7 7.0 32.06 0.33 86.7 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard P•aôific Fire Systems, Inc Page 5 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. M4 19.167 37.72 na M5 19.167 38.37 na M6 19.167 39.16 na M7 19.167 40.17 na M8 19.167 41.39 na M9 19.167 43.16 na M10 19.167 45.3 na Fl 19.167 49.09 na TORi 19.167 58.08 na BOR1 3.0 83.56 na BOR 0.0 86.09 na UG1 0.0 86.31 na 500.0 UG2 0.0 89.86 na UG4 0.0 91.63 na UG5 0.0 97.82 na TEST 0.0 99.3 na The maximum velocity is 23.44 and it occurs in the pipe between nodes M10 and Fl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fife Systems, Inc Page 6 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Ri -133.67 2.157 T 12.307 148.830 35.012 to 120.0 0.0 12.307 0.0 101 -133.67 -0.1306 0.0 161.137 -21.045 Vel= 11.74 101 29.90 2.157 0.0 8.000 13.967 K Factor = 8.00 to 120.0 0.0 0.0 0.0 102 -103.77 -0.0818 0.0 8.000 -0.654 Vel = 9.11 102 29.19 2.157 0.0 8.000 13.313 K Factor =8.00 to 120.0 0.0 0.0 0.0 103 -74.58 -0.0444 0.0 8.000 -0.355 Vel = 6.55 103 28.80 2.157 0.0 8.000 12.958 K Factor =8.00 to 120.0 0.0 0.0 0.0 104 -45.78 -0.0180 0.0 8.000 -0.144 Vel = 4.02 104 28.63 2.157 0.0 8.000 12.814 K Factor =8.00 to 120.0 0.0 0.0 0.0 105 -17.15 -0.0030 0.0 8.000 -0.024 Vel = 1.51 105 28.62 2.157 0.0 8.000 12.790 K Factor = 8.00 to 120.0 0.0 0.0 0.0 106 11.47 0.0015 0.0 8.000 0.012 Vel = 1.01 106 28.62 2.157 0.0 8.000 12.802 K Factor = 8.00 to 120.0 0.0 0.0 0.0 107 40.09 0.0140 0.0 8.000 0.112 Vel= 3.52 107 28.75 2.157 0.0 8.000 12.914 K Factor =8.00 to 120.0 0.0 0.0 0.0 108 68.84 0.0382 0.0 8.000 0.306 Vel = 6.04 108 29.09 2.157 0.0 8.000 13.220 K Factor = 8.00 to 120.0 0.0 0.0 0.0 109 97.93 0.0735 0.0 8.000 0.588 Vel = 8.60 109 29.72 2.157 T 12.307 5.500 13.808 K Factor =8.00 to 120.0 0.0 12.307 0.0 Rill 127.65 0.1200 0.0 17.807 2.136 Vel= 11.21 0.0 127.65 15.944 KFactor= 31.97 R2 -133.56 2.157 T 12.307 148.830 35.066 to 120.0 0.0 12.307 0.0 110 -133.56 -0.1304 0.0 161.137 -21.013 Vel= 11.73 110 29.99 2.157 0.0 8.000 14.053 K Factor =8.00 to 120.0 0.0 0.0 0.0 ill -103.57 -0.0815 0.0 8.000 -0.652 Vel = 9.09 111 29.29 2.157 0.0 8.000 13.401 K Factor =8.00 to 120.0 0.0 0.0 0.0 112 -74.28 -0.0441 0.0 8.000 -0.353 Vel = 6.52 112 28.89 2.157 0.0 8.000 13.048 K Factor =8.00 to 120.0 0.0 0.0 0.0 113 -45.39 -0.0176 0.0 8.000 -0.141 Vel = 3.99 113 28.75 2.157 0.0 8.000 12.907 K Factor =8.00 to 120.0 0.0 0.0 0.0 114 -16.64 -0.0028 0.0 8.000 -0.022 Vel = 1.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 7 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 114 28.71 2.157 0.0 8.000 12.885 K Factor =8.00 to 120.0 0.0 0.0 0.0 115 12.07 0.0015 0.0 8.000 0.012 Vet = 1.06 115 28.73 2.157 0.0 8.000 12.897 K Factor =8.00 to 120.0 0.0 0.0 0.0 116 40.8 0.0145 0.0 8.000 0.116 Vel = 3.58 116 28.86 2.157 0.0 8.000 13.013 K Factor =8.00 to 120.0 0.0 0.0 0.0 117 69.66 0.0391 0.0 8.000 0.313 Vel = 6.12 117 29.20 2.157 0.0 8.000 13.326 K Factor =8.00 to 120.0 0.0 0.0 0.0 118 98.86 0.0748 0.0 8.000 0.598 VeI= 8.68 118 29.86 2.157 T 12.307 5.500 13.924 K Factor =8.00 to 120.0 0.0 12.307 0.0 R12 128.72 0.1218 0.0 17.807 2.169 Vel= 11.30 0.0 128.72 16.093 KFactor= 32.09 R3 -133.16 2.157 T 12.307 148.830 35.260 to 120.0 0.0 12.307 0.0 119 -133.16 -0.1297 0.0 161.137 -20.897 Vel= 11.69 119 30.32 2.157 0.0 8.000 14.363 K Factor =8.00 to 120.0 0.0 0.0 0.0 120 -102.84 -0.0805 0.0 8.000 -0.644 Vel = 9.03 120 29.63 2.157 0.0 8.000 13.719 K Factor =8.00 to 120.0 0.0 0.0 0.0 121 -73.21 -0.0429 0.0 8.000 -0.343 Vel = 6.43 121 29.26 2.157 0.0 8.000 13.376 K Factor =8.00 to 120.0 0.0 0.0 0.0 122 -43.95 -0.0166 0.0 8.000 -0.133 Vel = 3.86 122 29.11 2.157 0.0 8.000 13.243 K Factor =8.00 to 120.0 0.0 0.0 0.0 123 -14.84 -0.0022 0.0 8.000 -0.018 Vel= 1.30 123 29.09 2.157 0.0 8.000 13.225 K Factor = 8.00 to 120.0 0.0 0.0 0.0 124 14.25 0.0021 0.0 8.000 0.017 Vel = 1.25 124 29.11 2.157 0.0 8.000 13.242 K Factor =8.00 to 120.0 0.0 0.0 0.0 125 43.36 0.0162 0.0 8.000 0.130 Vel = 3.81 125 29.26 2.157 0.0 8.000 13.372 K Factor = 8.00 to 120.0 0.0 0.0 0.0 126 72.62 0.0422 0.0 8.000 0.338 Vet = 6.38 126 29.62 2.157 0.0 8.000 13.710 K Factor =8.00 to 120.0 0.0 0.0 0.0 127 102.24 0.0795 0.0 8.000 0.636 Vet = 8.98 127 30.30 2.157 T 12.307 5.500 14.346 K Factor = 8.00 to 120.0 0.0 12.307 0.0 R13 132.54 0.1285 0.0 17.807 2.289 Vel= 11.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 8 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 132.54 16.635 KFactor= 32.50 R4 -125.87 2.157 T 12.307 156.830 35.820 to 120.0 0.0 12.307 0.0 128 -125.87 -0.1169 0.0 169.137 -19.765 Vel= 11.05 128 32.05 2.157 0.0 8.000 16.055 K Factor =8.00 to 120.0 0.0 0.0 0.0 129 -93.82 -0.0679 0.0 8.000 -0.543 Vel = 8.24 129 31.51 2.157 0.0 8.000 15.512 K Factor =8.00 to 120.0 0.0 0.0 0.0 130 -62.31 -0.0318 0.0 8.000 -0.254 Vel = 5.47 130 31.25 2.157 0.0 8.000 15.258 K Factor =8.00 to 120.0 0.0 0.0 0.0 131 -31.06 -0.0089 0.0 8.000 -0.071 VeI= 2.73 131 31.18 2.157 0.0 8.000 15.187 K Factor =8.00 to 120.0 0.0 0.0 0.0 132 0.12 0.0 0.0 8.000 0.0 Vel = 0.01 132 31.17 2.157 0.0 8.000 15.187 K Factor =8.00 to 120.0 0.0 0.0 0.0 133 31.29 0.0090 0.0 8.000 0.072 Vel= 2.75 133 31.25 2.157 0.0 8.000 15.259 K Factor =8.00 to 120.0 0.0 0.0 0.0 134 62.54 0.0320 0.0 8.000 0.256 Vel = 5.49 134 31.52 2.157 0.0 8.000 15.515 K Factor =8.00 to 120.0 0.0 0.0 0.0 135 94.06 0.0681 0.0 8.000 0.545 Vel = 8.26 135 32.06 2.157 T 12.307 5.500 16.060 K Factor =8.00 to 120.0 0.0 12.307 0.0 R14 126.12 0.1173 0.0 17.807 2.089 Vel= 11.07 0.0 126.12 18.149 KFactor= 29.60 R5 -87.38 2.157 2T 24.613 218.420 37.223 to 120.0 0.0 24.613 0.0 R15 -87.38 -0.0595 0.0 243.033 -14.457 Vel = 7.67 0.0 -87.38 22.766 K Factor = -18.31 R6 -85.44 2.157 2T 24.613 218.420 38.045 to 120.0 2E 12.307 36.920 0.361 M16 -85.44 -0.0571 0.0 255.340 -14.570 Vel = 7.50 0.0 -85.44 23.836 K Factor = -17.50 R7 -85.49 2.157 2T 24.613 218.420 39.058 to 120.0 2E 12.307 36.920 0.361 M17 -85.49 -0.0571 0.0 255.340 -14.589 Vel = 7.51 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fire Systems, Inc Page 9 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn -85.49 24.830 K Factor = -17.16 R8 -81.64 2.157 21 24.613 184.000 40.342 to 120.0 0.0 24.613 0.0 R18 -81.64 -0.0525 0.0 208.613 -10.943 Vel = 7.17 0.0 -81.64 29.399 K Factor = -15.06 R9 -81.75 2.157 2T 24.613 186.000 42.111 to 120.0 4E 24.613 49.226 0.0 R19 -81.75 -0.0526 0.0 235.226 -12.372 Vel = 7.18 0.0 -81.75 29.739 K Factor = -14.99 RIO -93.32 2.157 2T 24.613 184.000 44.055 to 120.0 0.0 24.613 0.0 R20 -93.32 -0.0672 0.0 208.613 -14.016 Vel = 8.19 0.0 -93.32 30.039 K Factor = -17.03 RI 133.67 2.157 1 12.307 0.830 35.012 to 120.0 0.0 12.307 0.361 Ml 133.67 0.l05 0.0 13.137 1.715 Vel= 11.74 0.0 133.67 37.088 K Factor= 21.95 R2 133.56 2.157 T 12.307 0.830 35.066 to 120.0 0.0 12.307 0.361 M2 133.56 0.1304 0.0 13.137 1.713 Vel= 11.73 0.0 133.56 37.140 KFactor= 21.92 R3 133.16 2.157 1 12.307 0.830 35.260 to 120.0 0.0 12.307 0.361 M3 133.16 0.1297 0.0 13.137 1.704 VeI= 11.69 0.0 133.16 37.325 KFactor= 21.80 R4 125.87 2.157 1 12.307 0.830 35.820 to 120.0 0.0 12.307 0.361 M4 125.87 0.1168 0.0 13.137 1.535 VeI= 11.05 0.0 125.87 37.716 KFactor= 20.50 R5 87.38 2.157 T 12.307 0.830 37.223 to 120.0 0.0 12.307 0.361 M5 87.38 0.0595 0.0 13.137 0.781 Vel = 7.67 0.0 87.38 38.365 KFactor= 14.11 R6 85.44 2.157 1 12.307 0.830 38.045 to 120.0 0.0 12.307 0.361 M6 85.44 0.0570 0.0 13.137 0.749 Vel = 7.50 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Eire Systems, Inc Page 10 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 85.44 39.155 KFactor= 13.65 R7 85.49 2.157 T 12.307 0.830 39.058 to 120.0 0.0 12.307 0.361 M7 85.49 0.0571 0.0 13.137 0.750 Vel = 7.51 0.0 85.49 40.169 K Factor= 13.49 R8 81.64 2.157 T 12.307 0.830 40.342 to 120.0 0.0 12.307 0.361 M8 81.64 0.0524 0.0 13.137 0.689 Vel = 7.17 0.0 81.64 41.392 KFactor= 12.69 R9 81.75 2.157 1 12.307 0.830 42.111 to 120.0 0.0 12.307 0.361 M9 81.75 0.0525 0.0 13.137 0.690 Vel= 7.18 0.0 81.75 43.162 KFactor= 12.44 RiO 93.32 2.157 T 12.307 0.830 44.055 to 120.0 0.0 12.307 0.361 MIO 93.32 0.0672 0.0 13.137 0.883 Vel = 8.19 0.0 93.32 45.299 KFactor= 13.87 R11 127.65 2.157 1 12.307 0.830 15.944 to 120.0 0.0 12.307 0.361 Mil 127.65 0.1199 0.0 13.137 1.575 VeI= 11.21 0.0 127.65 17.880 K Factor= 30.19 R12 128.72 2.157 T 12.307 0.830 16.093 to 120.0 0.0 12.307 0.361 M12 128.72 0.1218 0.0 13.137 1.600 VeI= 11.30 0.0 128.72 18.054 KFactor= 30.29 R13 132.54 2.157 T 12.307 0.830 16.635 to 120.0 0.0 12.307 0.361 M13 132.54 0.1286 0.0 13.137 1.689 VeI= 11.64 0.0 132.54 18.685 K Factor= 30.66 R14 126.12 2.157 T 12.307 0.830 18.149 to 120.0 0.0 12.307 0.361 M14 126.12 0.1172 0.0 13.137 1.540 VeI= 11.07 0.0 126.12 20.050 KFactor= 28.17 R15 -87.38 2.157 T 12.307 0.830 22.766 to 120.0 0.0 12.307 0.361 M15 -87.38 -0.0595 0.0 13.137 -0.782 Vel = 7.67 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Pacific Fare Systems, Inc Page 11 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn -87.38 22.345 K Factor = -18.49 R18 -81.64 2.157 T 12.307 0.830 29.399 to 120.0 0.0 12.307 0.361 M18 -81.64 -0.0524 0.0 13.137 -0.689 Vel = 7.17 0.0 -81.64 29.071 K Factor = -15.14 R19 -81.75 2.157 T 12.307 0.830 29.739 to 120.0 0.0 12.307 0.361 M19 -81.75 -0.0526 0.0 13.137 -0.691 Vel= 7.18 0.0 -81.75 29.409 K Factor = -15.07 R20 -93.32 2.157 T 12.307 0.830 30.039 to 120.0 0.0 12.307 8.662 M20 -93.32 -0.0672 0.0 13.137 -0.883 Vel = 8.19 0.0 -93.32 37.818 K Factor =-15.17 Mil 127.65 3.26 0.0 10.830 17.880 to 120.0 0.0 0.0 0.0 M12 127.65 0.0161 0.0 10.830 0.174 Vel = 4.91 M12 128.72 3.26 0.0 10.830 18.054 to 120.0 0.0 0.0 0.0 M13 256.37 0.0583 0.0 10.830 0.631 Vel = 9.85 M13 132.54 3.26 0.0 10.830 18.685 to 120.0 0.0 0.0 0.0 M14 388.91 0.1260 0.0 10.830 1.365 Vel = 14.95 M14 126.11 3.26 0.0 10.830 20.050 to 120.0 0.0 0.0 0.0 M15 515.02 0.2119 0.0 10.830 2.295 Vel = 19.80 M15 -87.38 3.26 0.0 9.920 22.345 to 120.0 0.0 0.0 0.0 M16 427.64 0.1503 0.0 9.920 1.491 Vel= 16.44 M16 -85.43 3.26 0.0 10.000 23.836 to 120.0 0.0 0.0 0.0 M17 342.21 0.0994 0.0 10.000 0.994 Vel = 13.15 M17 -85.50 3.26 3E 28.223 44.330 24.830 to 120.0 0.0 28.223 0.0 M18 256.71 0.0585 0.0 72.553 4.241 Vel = 9.87 M18 -81.63 3.26 0.0 11.750 29.071 to 120.0 0.0 0.0 0.0 M19 175.08 0.0288 0.0 11.750 0.338 Vel = 6.73 M19 -81.76 3.26 0.0 12.000 29.409 to 120.0 0.0 0.0 8.301 M20 93.32 0.0090 0.0 12.000 0.108 Vel = 3.59 0.0 93.32 37.818 KFactor= 15.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams F?cific F,ie Systems, Inc Page 12 System #1 .33/3000 (Peaked) overhead Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Ml 133.67 4.26 0.0 10.830 37.088 to 120.0 0.0 0.0 0.0 M2 133.67 0.0048 0.0 10.830 0.052 Vel = 3.01 M2 133.56 4.26 0.0 10.830 37.140 to 1 120.0 0.0 0.0 0.0 M3 267.23 0.0171 0.0 10.830 0.185 Vel = 6.02 M3 133.16 4.26 0.0 10.830 37.325 to 120.0 0.0 0.0 0.0 M4 400.39 0.0361 0.0 10.830 0.391 Vel = 9.01 M4 125.87 4.26 0.0 10.830 37.716 to 120.0 0.0 0.0 0.0 M5 526.26 0.0599 0.0 10.830 0.649 Vel = 11.85 MS 87.38 4.26 0.0 9.920 38.365 to 120.0 0.0 0.0 0.0 M6 613.64 0.0796 0.0 9.920 0.790 Vel = 13.81 M6 85.44 4.26 0.0 10.000 39.155 to 120.0 0.0 0.0 0.0 M7 699.08 0.1014 0.0 10.000 1.014 Vel = 15.74 M7 85.49 4.26 0.0 9.750 40.169 to 120.0 0.0 0.0 0.0 M8 784.57 0.1254 0.0 9.750 1.223 VeI= 17.66 M8 81.64 4.26 0.0 11.750 41.392 to 120.0 0.0 0.0 0.0 M9 866.21 0.1506 0.0 11.750 1.770 Vel= 19.50 M9 81.75 4.26 0.0 12.000 43.162 to 120.0 0.0 0.0 0.0 MIO 947.96 0.1781 0.0 12.000 2.137 Vel= 21.34 MIO 93.32 4.26 E 13.167 4.750 45.299 to 120.0 0.0 13.167 0.0 Fl 1041.28 0.2118 0.0 17.917 3.795 Vel = 23.44 0.0 1041.28 49.094 K Factor = 148.61 Fl 1041.28 4.26 E 13.167 29.250 49.094 to 120.0 0.0 13.167 0.0 TOR1 1041.28 0.2118 0.0 42.417 8.984 Vel= 23.44 TORi 0.0 4.26 B 15.8 16.167 58.078 to 120.0 S 28.968 71.102 7.002 BORI 1041.28 0.2118 T 26.334 87.269 18.483 VeI= 23.44 BORI 0.0 6.357 T 37.72 3.000 83.563 to 120.0 0.0 37.720 1.299 BOR 1041.28 0.0302 0.0 40.720 1.228 Vel = 10.53 BOR 0.0 8.27 E 28.468 7.000 86.090 to 140.0 0.0 28.468 0.0 UG1 1041.28 0.0063 0.0 35.468 0.224 Vel = 6.22 UG1 500.00 7.98 4E 108.73 78.000 86.314 Qa = 500 to 150.0 G 6.041 182.728 0.0 UG2 1541.28 0.0136 S 67.957 260.728 3.551 Vel = 9.89 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams cific Fire Systems, Inc Systeii #1 .33/3000 (Peaked) overhead Page 13 Date 2/19/20 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG2 0.0 7.98 T 52.855 77.000 89.865 to 150.0 0.0 52.855 0.0 UG4 1541.28 0.0136 0.0 129.855 1.769 Vel = 9.89 UG4 0.0 8.27 4E 113.872 15.000 91.634 to 140.0 Zic 0.0 113.872 4.512 * * Fixed Loss = 4.512 UG5 1541.28 0.0130 0.0 128.872 1.675 VeI= 9.21 UG5 0.0 7.98 T 52.855 50.000 97.821 to 150.0 G 6.041 58.895 0.0 TEST 1541.28 0.0136 0.0 108.895 1.484 Vel = 9.89 0.0 1541.28 99.305 K Factor = 154.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MATERIAL DATA SUBMITTAL SMAC New Tilt-Up Construction 5807 Van Allen Way Carlsbad, CA 92008 Pacific Fire Systems, Inc. 12316 Oak Knoll Road, Suite A Poway, CA 92064 858-883-2333 Phone • 858-883-2334 Fax November 16, 2010 Sprinkler 41 a MICROFASTO AND MicrofastHP® QUICK "44J I 1(1 I8IG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41 d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http://www.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 06662B and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Form No. F_081296 Replaces page 41a-f, dated October 8, 2010. (Updated deflector material for PN 06720B.) Sprinkler 41 b November 16, 2010 MICROFAST® AND MicrofastHP® QUICK NIKJNG]4 RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/57° =A, 155°I68° = B, 175°/79° = D, 2000/930 = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B* (available since 2003) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. *A 1/2" ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flats Protective Sprinkler Cap 10896 V Figure 1: Standard Sprinkler Wrench 10896W/B November 16, 2010 Sprinkler 41 c MICROFAST® AND MicrofastHP® QUICK N I 1(41 7N7G* RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color U Ordinary 135 0F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 00) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 00) 225 °F (107 00) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. ELM NH Carefully slide the wrench sideways around the protective cap, ensuring engage— ment with the sprinkler wrench flats. ®®A 1/2 ratchet is required (not available from Viking). Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers - Sprinkler Wrench 12144W/B*® for installing coated and/or recessed pendent sprinklers with protective caps, Sprinkler 41 d November 16, 2010 MICROFAST® AND MicrofastHP® QUICK N I KJ 7N7G*III[s1U'1.W RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I (UL) Temperature KEY Microfast® and MicrofastHP® Quick Response Pendent Sprinklers Finish A&' Escutcheon (If applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric2 Inches mm cULus4 NYC' VdS LPCB CE Standard Orifice 06662B VK302 1/2" 15 mm [ 5.6 1 80.6 2-1/4" 58 1 AiX, 131Y AIX, BIY A3 A3X, 133Y C3X, E3Y11 C3X, E3Y'3 Large Orifice 06666B VK352 3/4" 20 mm 80 115.2 2-3/8" 60 AiX, BIY AIX, BIY A3 A3X C311 -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AiX, B1Y AiX, B1Y A3 -- -- -- Small Orifice 06718B9 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX, B1Y AiX, BiY -- -- -- -- 067201319 VK331 1/2" 15 mm 4.2 57 2-1/4" 58 AiX, 131Y AiX, 131Y -- -- -- -- 06932B VK331 -- 10 mm 42 57 2-3/8" 60 -- -- A3 -- G272 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric2 Inches mm cULus4 NYC'° VdS LPCB CE G 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AIX, BIY AIX -- -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifice' 1229010 VK342 1/2" 115 mm 2.8 1 40.3 1 2-3/16" 1 56 1 AiX, 131Y AiX -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 "C), 175 "F (79 "C), 200 "F (93 "C), Approved Escutcheons and 286 "F (141 °C) Approved Finishes X - Standard surface-mounted escutcheon or B - 135°F (57 °C), 155 "F (68 "C), 175 °F (79 °C), and 200 °F i - Brass, Chrome-Enloy®, White the Viking Microfast® Model F-i Adjustable Polyester67, Black Polyester67, Escutcheon C - 155 "F(68 "C), 175 °F (79 "C), 200 °F (93 °C), and 286 °F and Black Teflon (141 °C) Y - Standard surface-mounted escutcheon or D - 135 "F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2 - Brass and Chrome-Enloy® the Viking Microfast® Model F-i Adjustable (141 °C) 3 - Brass, Chrome-Enloy®, White Escutcheon or recessed with the Viking E - 155 °F (68 "C), 175 °F (79 °C), and 200 °F (93 °C) Polyester7, and Black Polyester7 Micromatic® Model E-1 or E-2 Recessed F - 155 "F (68 "C), 175 °F (79 °C), and 286 °F (141 °C) Escutcheon G - 155 °F (68 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. 10Apçepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. Certified, Standard EN 12259-1, EC 0832-CPD-2001 0832-CPD-2003. .t -certificate of conformity and 12 ( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 13 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1008. 1-3/4" (44,5 mm) 2' (50,8 mm) Maximum 1-1/2" (38.1 mm) Minimum November 16, 2010 Sprinkler 41e MICROFAST® AND MicrofastHP® QUICK "'4I I I'(hl IIG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1 on page 41d) cULus Listing Requirements: Microfast and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16" (58,7 mm) minimum I 2-1/8" I 2-1/2" (63.5 mm) maximum (54 mm) 1/2' NPT (15 mm) 2-1/4" 1-5/8' (58 mm) (41 mm) Pendent Sprinkler 06662B (VK302) Installed with a standard 1/8' surface- mounted escutcheon. Installed with a Microf'ast Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8" Ceiling Opening Size: 2-1/8" (54 mm) 2-5/16" (58.7 mm) minimum (54 mm) 2-1/2' (63.5 rim) maximum ___ __ 11/4' \/ 1-1/8'(28 mm) Minimum 2 \/1i/8" pt mm) Mmu aximum (50,8 mm) Minimum aximum ______ Installed with a Micrornatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler 4lf November 16, 2010 MICROFAST® AND 'P411 1K] Ii1Gi i:iiusi. MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart 2 (FM) Temperature KEY Microfast® Quick Response Pendent Sprinklers 'f Finish AiX4- Escutcheon (If applicable)Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Base Part No.' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm Standard Orifice 06662B VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, 132Y Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AiX, 131Y Small Orifice4 06718B6 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX Approved Escutcheons Approved Temperature Ratings Approved Finishes X - Standard surface-mounted escutcheon or the Viking A- 135 °F(57 °C), 155 °F(68 °C), 175 °F(79 °C), 1 - Brass and Chrome-Enloy® Microfast® Model F-i Adjustable Escutcheon 200 °F (93 °C), and 286 °F (141 °C) . 2- Brass, Chrome-Enloy®, White Polyester', Y - Standard surface-mounted escutcheon or the °F °C), °F "C), °F B - 135 (57 155 (68 175 (79 °C) and Black Polyester5 Viking Microfast® Model F-i Adjustable Escutcheon °F °C) and 200 (93 or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated October 8, 2010. (Updated deflector material for PN 06720B.) At WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov Page 1 of 6 N 11(1 - MICROMATIC® STANDARD 4 RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Micromatic® Standard Response Upright VK200 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes, tem- perature ratings, and K-Factors to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for instal- lation in corrosive environments and are listed/approved as as indicated in the Approval Charts. Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Class Series 2000 VdS Approved: Certificates G414013, G414014, G498006, and G4060055 LPCB Approved: Certificate 096e106 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, EC-certificate of constancy of performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-I 003 NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatic rating: 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP, 3/4" NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric**) Glass-bulb fluid temperature rating: -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated. ttNot for FM Approval. Form No. F_032814 18.10.11 Rev 18.3.P65 Replaces Form No. F_032814 Rev 18.3 (Added P65 Warning.) Page 2 of 6 N II(II13® MICROMATIC STANDARD A A RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Upright Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffixes: Brass = A, Chrome = F, White Polyester = M-M, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-/W, ENT = JN Temperature Suffixes: 135 °F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 212°F (100 °C) = M, 286°F (141 °C) = G, 360 °F (182 °C) = H, 500 °F (260 °C) = L. For example, sprinkler VK200 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 18268AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches (Refer to Figure 1): Standard Wrench: Part No. 21475M/B (available since 2017). Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B (available since 2000). Wrench for Wax Coated Sprinklers: Part No. 13577W/B* (available since 2006) *A 1/2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® Standard Response Upright Sprinkler VK200 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Sprinkler Wrenches 2-3/8" (60 mm) Nominal Pipe r Engagement 7/16" (11 mm) Figure 2: Sprinkler Dimensions Form No. F_032814 18.10.11 Rev 18.3.P65 Page 3 of 6 N II(IFsIc® MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES I Sprinkler Temperature ' Sprinkler Nominal I Maximum Ambient Classification Temperature Rating' Ceiling Temperature Bulb Color U 0 or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Ultra High' 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings4: White and Black Polyester in all temperature ratings. ENT in all temperature ratings except 135 °F (57 °C). Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax' Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 ¶ (149 °C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT. For ENT coated automatic sprinklers, the waterway is coated. Wax melting point is 170 °F (76 C) for 286 °F (141 °C) temperature rated sprinklers. Form No. F_032814 18.10.11 Rev 18.3.P65 Page 4 of 6 MICROMATIC® STANDARD '.J IF(II1G RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Micromatic Standard Response Upright Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base Part SIN K-Factor Length (Refer also to UL Design Criteria.) Number' NPT BSP U.S. I metric2 Inches I mm cULus4 I VdS I LPCB ((81 Øio Standard Orifice 18268 VK200 1/2" 15 mm 8.0 115.2 2-1/4" 57 Al, B4, C5, D3, E6 A2 A2, B4 F3 F3 -- 18263 VK200 3/4" 20 mm 8.0 115.2 2-1/4" 57 Al, 134, C5, D3, E6 A2 A2, B4 F3 F3 -- 18266 VK200 - 20 mm 8.0 115.2 2-1/4" 57 Al, B4, C5, D3, E6 A2 A2, B4 F3 F3 -- 20381 VK200 3/4" -- 8.0 115.2 2-1/4" 57 - - - - -- G3 20377 VK200 -- 20 mm 8.0 115.2 2-1/4" 57 - - - - - G3 10220 VK200 1/2" 15 mm 8.0 115.2 2-1/4" 57 Al, 134, C5, D3, E6 A2 I A2, 134 F3 F3 -- 10141 VK200 3/4" 20 mm 8.0 115.2 2-1/4" 57 Al, 84, C5, D3, E6 A2' A2, B4 F3 F3 -- 10169 VK200 -- 20 mm 8.0 115.2 2-1/4" 57 Al, B4, C5, D3, E6 A21 A2, B4 F3 F3 -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F Approved Finishes (141 °C), and 360 °F (182 °C) 1 - Brass, Chrome, White Polyester56 and Black Polyester56 B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 2 - Brass, Chrome, White Polyester', and Black Polyester6 C-286°F(141 °C) 3 - Brass and Chrome D - 500 °F (260 °C)7 4 - Wax-Coated Brass and Wax Over Polyester' E - 155 °F (68 °C), 175°F (79 °C), 200°F (93 °C), 286°F (141 °C), 360°F (182 °C), and 500 °F (260 °C)7 5 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); °F °C) maximum ambient temperature allowed at ceiling = 150 (65 F - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 6 - ENT' °C) 360°F (182 G -155 °F (68 °C), 200 °F (93 °C), and 286 °F (141 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, and EC-certificate of constancy of performance 0832-CPR-50021. 9The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. ° MED Certified, Standard EN 12259-1, EC-certificate 0832-MED-1003. Form No. F_032814 18.10.11 Rev 18.3.P65 Page 5 of 6 NJIKJ MICROMATICO STANDARD l.1:II[.qiU,yIyA RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: The Viking Micromatic® Standard Response Upright Sprinkler VK200 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Step 1: Carefully slide the wrench around the deflector. Step 2: Carefully press the wrench downward and ensure engagement with the sprinkler wrench flats. Figure 3: Wax Coated Sprinkler Installation Form No. F_032814 18.10.11 Rev 18.3.P65 .4 Page 6 of 6 N II(IF MICROMATIC® STANDARD A A A RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Mt 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) emperature KEY inish Micromatuc'- Standard Response Upright Sprinklers [AtX :~Escutcheon(ffapplicable)l Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal K-Factor Overall Length FM Approvals3 Part Number' SIN (Refer also to Design Criteria below.) NPT I BSP U.S. I metric2 Inches mm Standard Orifice 18268 VK200 1/2" 15 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3 18263 VK200 3/4" 20 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3 18266 VK200 -- 20 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3 0 axammomaw =02" 102207 VK200 1/2" 15 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3 10141 VK200 3/4" 20 mm 8.0 115.2 - 2-1/4" 57 Al, B2, Cl, D3 10169 VK200 -- 20 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3 Approved Temperature Ratings A-i 35°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C), 286 °F (141 °C), and 360 °F (182 °C) Approved Finishes B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 1 - Brass, Chrome, White Polyester', and Black Polyester' 200 °F (93 °C) 2 - Wax-Coated Brass (corrosion resistant) C - 500 °F (260 °C)5 3- ENT D -155°F (68 °C), 175°F (79 °C), 200°F (93 °C), 286°F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)5 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion proofing for corrosive environments. 'The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. DESIGN CRITERIA -_FM (Also refer to Approval Chart 2.) FM Aonroval Requirements: The Viking Micromatic® Standard Response Upright SprinklerVK200 is is FM Approved as standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_032814 18.10.11 Rev 18.3.P65 Replaces Form No. F_032814 Rev 18.3 (Added P65 Warning.) NOTE: As of May 2018 all logos have been removed from the wrench boss. WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov Page 1 of 8 N II(II13 MICROMATIC® STANDARD lII[s1UuJM RESPONSE PENDENT SPRINKLER VK202(K8.0) 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Micromatic® Standard Response Pendent VK202 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes, temper- ature ratings, and K-Factors to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in cor- rosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. LISTINGS AND APPROVALS cus cULus Listed: Category VNIV FM Approved: Class Series 2000 [) VdS Approved: Certificate G414015, G414016, G4040098, G4060058, and G4060059 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and EC-certificate of constancy of performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and UL Design Criteria on page 4 for cULus Listing requirements, and refer to Approval Chart 2 and FM Design Criteria on page 5 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP, 3/4" NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (57 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000tt or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated. ttNot for FM Approval. Ordering Information: (Also refer to the current Viking price list.) Form No. F_032614 19.02.21 Rev 19.1 Replaces Form No. F_032614 Rev 18.2.P65 (Removed F-i Escutcheon.) Page 2 of 8 N II(II1G MICROMATIC® STANDARD 4 RESPONSE PENDENT - SPRINKLER VK202 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Order Micromatic® and MicromaticHP® Standard Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-W, Black Polyester = M-B, Wax Coated = C, Wax Over Polyester = V-W, ENT = JN Temperature Suffix: 135°F (57 °C) A, 155°F (68 °C) = B, 175°F (79 °C) = 0,200°F (93 °C) = E, 212°F (100 °C) = M, 286°F (141 °C) = G, 360°F (182 °C) = H, 500 °F (260 °C) = L. For example, sprinkler VK202 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 18269AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475MB (available since 2017). Standard Wrench for Wax Coated Sprinklers: Part No. 10896WB (available since 2000) Socket Wrench for Recessed Pendent Sprinklers: Part No. 13655WB* (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) Socket Wrench for Wax Coated Sprinklers: Part No. 13577WB* (available since 2006) °A ½" ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® Standard Response Pendent Sprinkler VK202 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_032614 19.02.21 Rev 19.1 Page 3 of 8 MICROMATIC® STANDARD 4 l:II[1•.7w RESPONSE PENDENT SPRINKLER VK202 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color Ordinary 135 OF (57 °C) 100 OF (38 °C) Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Extra High 360°F(182°C) 300°F(149°C) Mauve Ultra High' 500 OF (260 °C) 465 OF (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester and ENT Corrosion-Resistant Coatings4: White and Black Polyester in all temperature ratings. ENT in all temperature ratings except 135 OF (57 °C). Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 155 OF (68 °C) Lt. Brown Wax 175 OF (79 °C) Brown Wax 200 OF (93 °C) Brown Wax 286 OF (141 °C) Dk. Brown Wax5 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 OF (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 °C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Wax melting point is 286 OF (141 °C) temperature rated sprinklers. .Wrench Flat Protective Sprinkler Cap— ____ 21475 •• r:') 10896 Standard Sprinkler Standard Sprinkler Wrench for Wax Wrench 21475MB Coated Sprinklers 10896WB Figure 1: Standard Sprinkler Wrenches Form No. F_032614 19.02.21 Rev 19.1 Page 4 of 8 MICROMATIC® STANDARD I RESPONSE PENDENT SPRINKLER VK202 (K8M) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I Ternperatwe KEY Finish MicromatiO Standard Response Pendent Sprinklers A&II Escutcheon (If applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base Part SIN K-Factor Length (Refer also to UL Design Criteria.) Number' NPT BSP U.S.I metric2 Inches 1mm cULus4 j VdSj LPCB I (( 8 1OI :. Standard Orifice 18269 VK202 1/2" 15 mm 80 115.2 2-1/4" 57 Al, B4, B1Y, C5, D3, E6, G6Z A2 A2,134 - -- - 18264 VK202 3/4" 20 mm 8.0 115.2 2-1/4" 57 Al, B4, B1Y, C5, D3, E6, G6Z A2 A2, B4, 132Y F3, G2Y - - 18267 VK202 - 20 mm 8.0 115.2 2-1/4" 57 Al, B4, B1Y, C5, D3, E6, G6Z A2 A2, B4, 132Y F3, G2Y - - 20380 VK202 3/4" - 8.0 115.2 2-1/4" 57 - - -- - - H3 20376 1 VK202 I - 20 mm 1 8.0 1 115.2 1 2-1/4" 1 57 1 H3 10 9 1#aXQM0MM&MWWft@20 __- - 10223 VK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 Al, B4, B1Y, CS, D3, E6, G6Z A2 - - -- - 10142 VK202 3/4" 120 mm 80 115.2 2-5/16" 59 Al, B4, B1Y, CS, D3, E6, G6Z A2 I A2, 132Y JF3,G2Y F3 - 10170 VK202 - 20 mm 80 115.2 2-3/8" 60 Al, B4, B1Y, CS, D3, E6, G6Z A2 I A2, 132Y JF3,G2Y F3 L - Approved Temperature Ratings A - 135 OF (57 °C), 155 OF (68 "C), 175 OF (79 °C), 200 OF (93 °C), 286 OF (141 "C), and 360 OF (182 °C) B - 135 OF (57 °C), 155°F (68 °C), 175°F (79 °C), Approved Finishes and 200 OF (93 °C) 1 - Brass, Chrome, White Polyester56 and Black Polyester56 Approved Escutcheons C - 286 OF (141 °C) 2 - Brass, Chrome, White Polyesters, and Black Polyester' X - Recessed with the Viking Micromatic® Model D - 500 OF (260 °C)7 3 - Brass and Chrome E-1, E-2, or E-3 Recessed Escutcheon Y - Standard surface-mounted escutcheon or re- E - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 4 - Wax-Coated Brass and Wax Over Polyesters cessed with the Viking Micromatic® Model E-1, E-2, °C),286°F (141 °C), 360 OF (182 "C), and 500 OF - High Temperature 200 OF (93 °C) Wax Coating (corrosion or E-3 Recessed Escutcheon z - Standard surface-mounted escutcheon or re- resistant); maximum ambient temperature allowed at ceiling = F - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 150 OF (65 °C) cessed with the Viking Micromatic® Model E-1 286 OF (141 °C), and 360 OF (182 °C) 6- ENT5 G - 155 OF (68 °C), 175 OF (79 °C), and 200 OF (93 °C) H - 155 OF (68 °C), 200 OF (93 °C), and 286 OF (141 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metnc K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 OF (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-0021 and 0832-CPD-2003. 9The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. 10 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008. Form No. F_032614 19.02.21 Rev 19.1 . •. 'p.t - I - Page 5 of 8 N II(It1c3® MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK202 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart I.) cULus Listing Requirements: The Viking Micromati& Standard Response Pendent Sprinkler VK202 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler wrench 13655WB** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) *4 Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655WB for Recessed Pendent Sprinklers Form No. F_032614 19.02.21 Rev 19.1 Page 6 of 8 MICROMATIC® STANDARD N1KJNG*__0 RESPONSE PENDENT SPRINKLER VK202 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature ty I Micromatic Standard Response Pendent Sprinklers I h- Finish Maximum 175 PSI (12 bar) WWP I A 4- Escutcheon Qfapplieable)j Sprinkler Base Thread Size F Nominal K-Factor F Overall Length FM Approvals' Part Number' SIN (Refer also to Design Criteria below.) NPT BSP [ U.S. metric2 Inches mm Standard Orifice 18269 VK202 1/2" 15 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3, B1Y, E3Z 18264 VK202 3/4" 20 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3, B1Y, E3Z 18267 VK202 - 20 mm 8.0 115.2 2-1/4" 57 Al, B2, Cl, D3, BlY, E3Z 10223 VK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 Al, B2, Cl, D3, BlX, E3Z 10142 VK202 3/4" 20 mm 80 115.2 2-5/16" 59 Al, B2, Cl, D3, BIX, E3Z 10170 VK202 -- 20 mm 8.0 115.2 2-3/8" 60 Al, 132, Cl, D3, B1X, E3Z Approved Temperature Ratings Approved Escutcheons A-1 35'F(57-C), 155°F(68°C), 175°F(79°C), 200°F(93°C), X - Recessed with the Viking Micromatic® 286°F (141 °C), and 360°F (182 °C) Model E-1, E-2, or E-3 Recessed B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and Approved Finishes Escutcheon 200 °F (93 °C) I - Brass, Chrome, White Polyester', and Black Polyester' Y - Standard surface-mounted escutcheon C - 500 °F (260 °C)5 or recessed with the Viking Micromatic® D- 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286°F 2 - Wax-Coated Brass (corrosion resistant) Model E-1, E-2, or E-3 Recessed Escutcheon (141 °C), 360 °F (182 °C), and 500 °F (260 °C)5 3- ENT6 E - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Z - Standard surface-mounted escutcheon or re- cessed with the Viking Micromatic® Model E-1 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. 'The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. DESIGN CRITERIA - FM (Also refer to Approval Chart 2.) ItiIflLi-iIjti11lI The Viking Micromatic® Standard Response Pendent Sprinkler VK202 is is FM Approved as standard response Non-Storage pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F032614 19.02.21 Rev 19.1 Page 7 of 8 N II(lN® MICROMATIC® STANDARD I RESPONSE PENDENT SPRINKLER VK202 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com £ ; • Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinklger wrench flats. Wax Coated Pendent Sprinkler Sprinkler wrench 13577WB** must be used for installing wax coated sprinklers. ** A 1/2" ratchet is required (not available from Viking) Step 2: Carefully press the wrench upward and ensure engagement with the sprinkler wrench flats. Figure 3: Wrench 13577WB for Wax Coated Sprinklers Form No. F_032614 19.02.21 Rev 19.1 1-1/8" (29 mm) Mm. 2`2 L2 (51 mm) Max. Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Page 8 of 8 4 l:IIE.L1u.7M RESPONSE PENDENT SPRINKLER VK202 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum N PT. 1 (57 _5m) Installed with a standard 1/8" surface-mounted escutcheon Figure 4: Sprinkler Dimensions with a Standard Escutcheon -11 ----L (54 mm) 1-314" (45 mm) Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 5: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_032614 19.02.21 Rev 19.1 Replaces Form No. F_032614 Rev 18.2.P65 (Removed F-i Escutcheon.) FM Approved and Fully Listed Sprinkler Pipe Wheatland's WLS steel fire sprinkler pipe is hot-dip galvanized to meet FM requirements for dry systems and is UL, C-UL and FM Listed. Approvals and Specifications The product meets or exceeds the following standards: ASTM: A795, Type F, Grade A ANSI/ASME 131.20.1 pipe threads NFPA13 Manufacturing Protocols WLS is subjected to the toughest possible testing protocols to assure the highest quality and long-lasting performance. Finishes and Coatings WLS is finished in black or hot-dip galvanized. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SPECIFICATIONS NPS NOM OD NOM ID UL CRR WLS WLS I Schedule lscheduie WLS Schedule Nonhlliflr p7fl7rr1 10 40 J 40 wt./ft. j Lift 21- J Lift 251 1 1.315 1.087 N/A 1.049 .57 1.00 1.462 70 60 11/411 1.660 1.426 1.442 1.380 .46 1.00 1.928 55 1 45 1½ 1.900 1.650 1.682 1.610 .64 1.00 2.370 45 40 2J 2.375 2.125 2.157 2.067 .52 1.00 3.004 35 30 Calculated using Standard (IL CRR formula, UL Fire Protection Directory, Category VIZY. C@ APPROVED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: fl BLACK n HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 . L P 800.257.8182 1 F 724.346.7260 1 info a wheatland.com I wheatland.com SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm [ in. mm in. mm b&/ft. [ kg/rn CRR [ Lift 1¼ 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 iyz1 1900 483 1682 427 109 277 209 311 58 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 7 21/2 2.875 73.0 2.635 66.9 1 .120 305 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 1 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 Steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES - In mm in mm l in mm [bs/ft] kg/rn CRR- Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 - .1 1% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1/a 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 J. 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, (ii. Fire Protection Directory, Category VIZY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). (9) C@ APPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK 0 HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 I F724.346.7260 I info a wheatland.com I wheatland.coni i gg VSR Q POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN 12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)- UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) lO.OAmpsat 125/250VAC 2.0Ampsat30VDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2 conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing j when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2' DN50 VSR-2 1144402 2 1/2' DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 DN100 VSR-4 1144404 - VSR-5 1144405 DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTION I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. -- Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO Phone: 866-956-1211/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV L PAGE 1 OF 4 3/09 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Retard Adjustment Fig. 1 DC NOT LEA VE COVER OFF FOR J NE.kTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms .Y TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE <POINTS IN DIRECTION OFWATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect P 0 3 0 DIRECTION OF WATERFLOW --Th ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direction only) IIWG. U46-it ADAPTER ADApT0g -..4 20mm ±2mm MAX. DNSO ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DVC# I 46-IF Compatible Installation _Pipe/ _Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-rn VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .1251-062 33.0±2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ±.125 50.8 ± 2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3,2 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - - VSR-6 6 DNISO 6.625 168.3 0.134 3.40 0.280 1 7.11 1 0.197 1 5.0 0.157 4.0 VSR-8 8 DN200 8.625 1 219.1 1 0.148 3.76 0.322 1 8.18 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146-REV L PAGE 2 OF 4 3/09 GREEN GROUND PAGE 3 OF 4 (2.)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 2 Fig. 3 To remove knockouts: Place screwdriver at Break out thin section of cover when inside edge of knockouts, not in the center, wiring both switches from one conduit \ entrance. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Term inal OW. #1146-16 : n uninsulated section of a single conductor should not be looped ound the terminal and serve as two separate connections. The ire must be severed, thereby providing supervision of the )nnection in the event that the wire become dislodged from under e terminal. Failure to sever the wire may render the device operable risking severe property damage and loss of life. o not strip wire beyond 3/8" of length or expose an uninsulated )nductor beyond the edge of the terminal block. When using randed wire, capture all strands under the clamping plate. ME Fig. 5 Typical Electrical Connections BELL Notes: POWER LSOURCE SUITABLE I. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. : FOR BELL A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. WA I trr I LUW ZONE 9 EOLR ON FIRE For supervised circuits, see "Switch Terminal Connections" MM IVA42 PANEL drawing and warning note (Fig. 4). Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 7 Mounting Dimensions 5.56 in 3.50 in 200 in b (89.0 rnrn ) (50.8 rnm)"t (1412 mm) Fig. 8 2.34 in II (59.4 mm)) PIPE DIA. UBOLT NUT ___S\ ,, J \1!1l (+ 1334mm) y + 5.25 in U.BOLT WASHER PIPE SADDLE--/ DWG 1146-14 PIPE PLASTIC PADDLE--'M U-BOL NOMINAL PIPE DIA. +1.75 in (+44,5 MM) FOR DN 50- ON 652-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR ON 80- DN 200 3-8 in PRINTED IN USA MFG. #5401146 - REV L 3/09 a , - (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 6 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTION OFCO VER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING /SCREWS RETARD/SWITCH ASSEMBLY AU (2) LOCATING PINS fl i DO NOT REMO\ (2) RETARD Hot. SCREWS (2) LOCATU BOSSES IN DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV L PAGE 4 OF 4 3/09 U 1/2 Throvgh 8 • Max. Test Pressure: 600 psi (4$.0 Bars) Working Pressure $00 psi (21,5 Bars) U Working Teropture: 2$0F (120CC) Factory Installed ULApproved Tampered Switch for in and Outdoor (,)s I Trademark! Ofobal Safety Producta, Inc, D GROOVED END ESCRIPTION BUUERFLY VALVE <> © APPROVED USTED I COMPONENI MATERIAL Body Ductile Iron, EPDM Encapsulated Disc Al-Bronze, Ni-Cr Plated Stem Stainless Steel, Hardened & Tempered Housing Ductile Iron (ASTM A-536) Hand Wheel Ductile Iron (ASTM A-536) VALVE [ T 1 1E I H SIZE IL ITEM CODE__L_A__][__B 2 1/2" UFP025 4.1" 380" 6,61" 288" 39" 4.92" 3" UFP026 4.41" 3.80" 6.61" 3.50" 5.67" 4.92" 4 UFP027 571 454 661 450 697 492 6" UFP028 7.05" 5.21" 8.19" 6,63" 8,31" 8.86" 0.27" 81, UFP029 803' 580 819 862 929 886 095 ®SIGMA Piping Products (800) 999-250 sigma pipingp rod ucts,corn The AGF Manufacturing Inc. Model 101 1A TESTANDRAIN® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. The Model 1011A complies with the requirements of NFPA-1 3 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). The Model 1011A TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 3/4" to 2" NPT and BSPT, with all specifiable orifice sizes W (2.8K), 7A6" (4.2K), ½' (5.6K), 17/3211 (8.0K), /8" (11.2K, ELO), 3/4' (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTANDRAIN® valves. Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTANDRAN is a registered trademark of AGF Manufacturing Inc. csioi 1A 10/09 DIMENSIONS MODEL 1011 A - FRONT VIEW Orifice Size Available: /8", 7A6", 1/2", 17/32", ELO (5/8)*, ESFR (3/4 )*, & Q5** SIZE A B C 0 E F G H 3 /411 79/i&' 11/2 26" 3W8" 3" 11W16" 4/16 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 79/i&' 11/2" 26" 3 /8" 3'é" 11 /16" 49/16" 6'" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) 1 (117 mm) (162.5 mm) 11/4 715/16" 111/16" 29/16" 4¼" 3/8" 115/16" 59/16" 51/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 81W16" 113I6" 31/4" 51/16" 3/8" 2/8" 81/4" 10/8" (227 mm) (45 mm) (81.5mm) (127mm) (99 mm) (67 mm) (207 mm) (274 mm) 72' 81W16" 11V16" 31/4" 51A6" 3/8" 25/8" 81/4" 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) * Available on 11/4' to 2" size units only ** Available on 11/2" and 2" size units only THE MODEL 1011 A PROVIDES ALL OF THE FOLLOWING.... From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve MODEL 1011 - PLAN VIEW MATERIALS Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid APPROVALS UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM AGF Manufacturing Inc. Job Name: 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Architect: Fax: 610-240-4906 Engineer: www.testandrain.com Contractor: SAMMYS X-Pre s Vertical Mou it I ROD PART - MODEL DESCRIPTION PULLOUTQus ULTIMATE TEST LOAD TEST Ii MIN MAX BOX CASE APPLICATION SIZE NUMBER THICK THICK QTY QTY (LBS) LISTED (LBS) (IBS) — — — — 8181922 XP 200 X-Press 200 1146 185 (Luminaire) .027 .125" 25 125 Metal Deck (22 ga) 250 (Luminaire) .056" 850 (2½" Pipe) 940 (2" Pipe) .027" 8150922 XP 20 X-Press 20 1146 185 (Luminaire) 1475 (4"Pipe) .027" .125" 25 125 Metal Deck (22 ga) 250 (Luminaire) .056" 283 (Conduit & (able) 1250 (3½" Pipe) .060" 3/8" 8153922 XP 35 X-Press 1783 85 (Luminaire) 940 (2" Pipe) .105" .125" 25 125 Pullin (16 ga) 250 (Luminaire) 1475 (4"Pipe) .027" __ 416((onduit&Cable) .056" Metal Deck Sammy -Press 20 :1146(22 ga) 3/88150922XP2O 25 850 (2½ Pipe) 125X Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWCs 35 PCF (Ibs/ft3) (Pre-Pour) Metal Deck ___ (Post-Pour) Sathmy X-Press SELECTION CHART Pre-Pour Structural Concrete @3000 psi —r~ J~~— — Fr— — Post-Pour Range Ii LWC!5 35 PCF (IbsIft°l TSIZE PART MODEL DESCRIPTION ULTIMATE PULLOUT TEST LOAD MIN MAX BOX CASE APPLICATION UMBER s THICK THICK QTY QTY (LBS) LISTED (LBS) (LBS) — — — — 750 (2" Pipe) rE,)gtjpEtAE 170 vertical (Luminaire) FOR )PatentpQrdr5 3/8" 8294922 SXP 20 Swivel X20 -Press 1061 (22 go Vertical) Off 80 @45° (Luminaire) 283 vertical 635 (2" Pipe) .027" .125" 25 125 Metal Deck 829 (45° Vertical) (Conduit & Cable) 233 @ 45° RO.Q pcfIS (Conduit & Cable) 1500(4" Pipe) 250 vertical (Luminaire) Swivel 1675 (16 ga Vertical) 80 @90° (Luminaire) 3/8" 8295922 SXP3S X-Press 35 1558 (89' Off Vertical) 500 vertical 635 (2" Pipe) .060" .125" 25 125 Pullin (Conduit & Cable) 333@89° (Conduit &Cable) 1/2" 8272957 SXP 2.0 Swivel 1061 (22 ga Vertical) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45° Off Vertical) 1/2" 8271957 SXP3.5 Swivel 1675 (16 ga Vertical) .060" .125" 25 125 Purlin X-Press 3.5 1558(89° Off Vertical) SAMMYS X-Press Horizontal Mount — ROD PART MODEL ULTIMATE DESCRIPTION PULLOUT TEST' LOAD I TEST LOAD — MIN — MAX — BOX — CASE APPLICATION SIZE NUMBER THICK THICK QTY QTY (LBS) LISTED (LBS) -P... Sidewinder 1250 (31/2" Pipe) 3/8" 8293957 SWXP35 1798 (16 ga) 80 (Luminaire) .060" .125" 25 125 Pullin X-Press 35 416 (Conduit&Cable( ITW Construction Products Call our toll free number 800-387-9692 or omit www.itwcsnstruction.ca for general information. S14 SAiIff1''S Visit 11W Buitdex'o SAMMYS web site www.sammvsuperscrew.com for the most current product and technical information. Pending (SWXP) FEATURES O Structural attachment and restraint component combined; ready for selected rod. O Access to the back of fastener not required. O Does not require use of a retaining nut. o Quick and easy installation. BENEFITS 0 Reduced installation cost. O Design flexibility. O Less on site material (GO GREEN). O Less material coordination. 0 Aesthetically pleasing. FOR 3/8" A 'I1 RODS SXP 20 AND SXP 35 FOR 3/8" ROD Structural attachment for installation of branch/end of line restraint using 3/8" all thread (.299" CD) or end thread rod (.374" CD). SXP 20 for 3/8" Rod: Designed for use in metal deck ranging from 22 ga. through 18 ga. in low slope or pitched roof designs (12/12). SXP 35 for 3/8' Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8 in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3,5.3.8, (2007). SXP 2.0 AND SXP 3.5 FOR 1/2" ROD Structural attachment for installation of branch/end of line restraint using 1/2 all thread (.405" OD) or end thread rod (.500" OD). SXP 2.0 for 1/2" Rod: Designed for use in metal deck ranging from 22 ga. through 18 ga. in low slope or pitched roof designs (12/12). SXP 3.5 for 1/2" Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8" in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3.5.3.8, (2007). FOR 3/8" ROD AND 1/2" ROD Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal load Tables below. Maximum Angle: 45° from horizontal Material: Carbon Steel Screw Description: 1/4-20 x 1-1/8" with expandable sleeve Finish: Electro-Zinc Testing: Tested to GR-63-CORE Standard for performance in structural steel in seismic restraint applications as outlined for use in NFPA 13(2007), 9.3 at an independent test lab. The calculated force used for the testing was equal to that found in a Zone 4 and an 8.4 Richter scale seismic event. Listing for 3/8" Rod: UL 203 listed as pipe hanger File EX 5098 - SXP 20 (22 ga.) 0-45° from horizontal -2" Schedule 40 pipe - SXP 35 (16 ga.) 0-90° from horizontal - 3-1/2" Schedule 40 pipe - us UL 203A File EX 15565 Listing for 1/2" Rod: UL 203A File EX 15565 USTED SELECTION [CHART I1. V IA1:ed 7!m ROD PART MODEL MIN MAX ' APPLICATION - BOX - CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8 8294922 SXP 20 22 ga 18 ga. Metal Deck 25 125 The SWXP 35 must be installed 1/2 8272957 SXP 2.0 22 ga 18 ga. Metal Deck 25 125 with WIT Tool (Part No. 3/8" 8295922 SXP 35 16 ga 1/8' Purlin ..2....... 8194910); pre-drilling required. 1/2" 8271957 SXP 3.5 16 ga 1/8' Purlin 25 _. 125 Least Radius of Maximum Rod Length for hr (ft) Restraint Shape and Size ' Nominal Diameter Area On.')Gyration, r (in.) hr = 100 I hr = 200 I hr = 300 I hr = 400* Rods (all thread) 3/8 in. 0.07 0.075 0.6 I 1.3 I 1.9 2.5 I I I 1/2 in. 0.129 0.101 0.8 I 1.7 I 2.5 I 3.4 3/8 in. 0.11 0.094 0.8 I 1.6 I 2.4 I 3.1 Rods (threaded at ends only) I I I 1/2 in. 0.196 1 0.125 1 1.0 1 2.1 I 3.1 4.2 Reference: NFPA 13, (2007) * Reference: NFPA 13, (2010) IIT Construction Produce Call our toll free number 800381'9692 or visit www.itwconstruction.ca for general information. Visit 11W Buildeos SAMM YS web site www.sammysupersaew.com for the most current product and technical information. SAMMYS S15 .11 SAMMYS X-Press for Seismic Restraint DESCRIPTION (SIDEWINDER) SWXP IiFORtll.iIl I1] Structural attachment for installation of branch/end of line restraint using 3/8' threaded rod. Used primarily in purlin, bar joist, or other steel structural members. These fastening systems provide a secure and economical attachment to the structure. The SWXP 35 model provides upper structural attachment in a range of steel thicknesses, from 16 ga. through 1/8". An expandable sleeve is included with each fastener, eliminating need for retaining nut. Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. Maximum Angle: 45° from horizontal Material: Carbon Steel Screw Description: 114"-20 X 1-1/8" with expandable sleeve Finish: Electro-Zinc (cap & screw) Testing: BX Report# R-1362 Listing: UL 203 as a pipe hanger Q us UL 203A pending LISTED SELECTIONr CHART : SAMMYS Sidewinders Concrete - Seismic _ Restraintfor ROD PART MODEL MIN MAX SIZE NUMBER THICKNESS THICKNESS 3/8' 8293957 SWXP35 16ga. 1/8 VI I APPLICATION BOX I CASE I INSTALLATION TOOL QTY QTY I The SWXP 35 must be installed Steel Purlin or Bar Joist 25 125 I with WIT Tool (Part No. 8194910); I pre-drilling required. PERFORMANCE TABLES Restraint Shape and Size Nominal Diameter __ Area (in .2) Least Radius of Gyration, r in. _______________ Maximum Rod Length for hr (ft) hr = 100 hr = 200 hr = 300 I/r = 400* Rods (all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 Rods (threaded at ends only) 3/8 in. 1 0.11 1 0.094 0.8 1.6 2.4 3.1 1/2 in. 1 0.196 1 0.125 1 1.0 2.1 3.1 1 4.2 Reference: NFPA 13, (2007) *Reference: NFPA 13, (2010) IT Construcdon Produce (all our toll free numben800-387-9692 or visit www.itwconstruction.ca for general information. S 1 6 SAMMYS Visit 11W tuildex's5AMMYS web site www.sammesunerscrew.com for the most current product and technical information. Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. C®USIJSTED Fig. 200 21/2' -8 Fig. 200R 1/2" -2" Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 2/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 7/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.186.5266 wwwtolco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13/16 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1A6 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of California OSHPD Approved ç Vt. US US!o D Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8, 1/2 and 5/8 rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8' rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 851.737.5599 • FAX: 951.737.0330 .1 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8 thru 7/8 rod by 4 thru 16' length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1 Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 1/2 9/16 Specify Specify 2 5/8 11/16 3/4 13/16 Specify Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. Component of State of California OSHPD Approved US LISTEO Seismic Restraints System Q @ OFFICEJMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 .4 www.tolco.com All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 32 Fire Protection Solutions B-Line by WT.N Pipe Clamps B3140 - Standard Pipe Clamp (TOLCO Fig. 4) B3140C - Standard Pipe Clamp PVC Coated (TOLCO Fig. 4PVC) c.us Size Range: 133140/133140C Size 1/2 (15mm) thru 12 (300mm) pipe. LISTED Material: Steel Function: Recommended for the suspension of non-insulated pipe or insulated pipe with B3151 shields. (Use B3200 weldless eye nut, B3210 eye rod or B3211 welded eye rod.) B3140F and B3140C are Bolt Size designed to reduce noise and vibration and/or prevent electrolysis. Approvals: Underwriters Laboratories Listed in the USA (UL), Canada (cUL) 3/4 (20mm) - 12' (300mm), and approved by Factory Mutual Engineering (FM), 3/4 (20mm) - 8(200mm). Federal Specification I B WW-H-1 71 E & A-A-I 192A, Type 4, and Manufacturers Standardization c Society ANSI/MSS SP-69 & SP-58, Type 4. - - Note: For piping that requires sway bracing refer to Fig. 4A. Maximum Temperature: - 750°F (399°C) B Finish: Plain. Contact B-Line for alternative finishes c -- - ---:J A and materials. - Order By: Figure number, pipe size and finish. Order Note: When ordering B3140F allow for /16' (4.8mm) felt on each half of clamp. _.t, Designed to meet or exceed requirements of FM DS 2-0. LJ B3140C Pipe Approx. Part Size A B C Bolt W000 No. in. (mm) in. (mm) in. (mm) in. (mm) Size lbs. (kg) [ B3140-1/2 1/2" (15) /8" (9.5) 31/32" (24.6) 117/32" (38.9) /1"-18 30 (13.6) B3140-3/4 3/4' 1201 /16' (14.3) 1/32' 127.81 121/32" (42.0) /16'-18 31 (14.0) B3140-1 - 1 (25) -- /16" (14.3) - 1/16" (33.3) 1I8" (41.6) /16"-18 33 (14.5) B3140-11/4 11/4" (32) 17/32' (13.5) 1/16" (36.51 2 (50.8) -- /16-18 . .- 39 (17.7) B3140-11/2 11/2" (40) 19/32" (15.1> 121/32' (42.0) 2/32" (56.4) - /16'-18 41 (18.6) .. ...................................--- B3140-22' (50) /16' (14.3) !' 40L 23/4' (69.8) - - 1/2 .13 118 (53.5) r B3140-21/2 21/2" (65) /8" (15.9) 221/32" (67.5) 3/32" (83.3) 1/2"13 130 (58.9) B3140-3 3' (75) 5/8' (15.9) 215/16 (74.6) 3/16" (90.5) 1/2 .13 150 (68.0) [ B3140-31/2 31/2" (90) 5/ (15.9) 3/32' (80.1) 325/32" (96.0) - 1/2"13 158 (71.6) B3140-4 4' (100) 3/4" (19.0) 3/16' (90.5) 4/16" (109.5) /81--11 239 (108.4) B3140-5 5 (125) 3/4 (190) 41/8 (1048) 4/8 (1238) 5/811-11 272 (1234) B3140-6 6' (150) /8" (22.2) 415/16' (125.4) 513/16' (147.6) /4"-10 541 (245.4) B3140-8 8" (200) 1" (25.4) 61/16 (154.0) 615/16 (176.2) /4"-10 642 (291.2) B3140-10 10 (250) 1" (25.4) 73/9' (187.3) 811/16" (220.7) /8'-9 1366 (619.6) B3140-12 - - 1Z'(300) 1" (25.4) 8/16' (214.3) 93/4' (247.6) /8"-9 1543 (699.9) Bar joist shown atta' to various root mate Component of State of California OHPD Approved Seismic Restraints System Fig. 825A — Bar Joist Sway Brace Attachment Size Range - One size accommodates all TOLCO Fig. 900 Series sway brace attachments. Maximum Horizontal Design Load 1600 lbs. Material - Carbon Steel Function - To attach sway bracing to steel open web structural members. Features - This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist. Break off head bolt design assures verifi- cation of proper installation. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - The Fig. 825A is the structural attachment com- ponent of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe" and a TOLCO "braced pipe" attachment to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 825A on the steel beam, tighten the cone point set bolts until bolt heads break off. Attach other TOLCO transitional attachment fit- ting, Fig. 909, 910, 980 or 986. Transitional fitting attachment can pivot for adjustment to proper brace angle. Important Structural Note: Maximum Design Load 1600 Lbs. The TOLCO Fig. 825A has significant UL established design loads, however, structural issues related to the steel joist member require restricted location installation for all bracing. Steel Joist Manufacturers require that all earthquake bracing connections be within 6" of the cord panel point. Installation of the Fig. 825A is not restricted to the two outer third sections of the joist. For greater design loads, refer to TOLCO Fig. 825. Finish - Plain Order By - Figure number and finish Patent #6,098,942 - '4lay -IYVt UI any direction Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-Line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Fig. 1000 - "Fast Clamp" Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range - Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/40 Schedule 40 'PS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation - The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete bracing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1.000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Maximum Design Load 1" thru 4" pipe size - 2015 lbs. - 6 size - 1265 lbs. FM Approved Design Loads* 1" - 21/2" - 600 lbs. 3" - 4" - 700 lbs. C®US IIS1ED TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 1 155 Fig. 909 - No-Thread Swivel Sway Brace Attachment c®ususia Size Range - 1 bracing pipe. For brace pipe sizes larger than 1" Component of State of TOLCO F OOA use Fig. UV. California OSHPD Approved Seismic Restraints System Material - Carbon Steel, hardened cone point engaging screw Function - The structural component of a sway and seismic bracing system. Features - This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. No ,( H threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. Application Note - The Fig. 909 is used in conjunction with the A TOLCO Fig. 1000, Fig. 1001, Fig. 4(A) or Fig. 4L pipe clamp, and joined together with bracing pipe. Sway brace assemblies are intend- ed to be installed in accordance with NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint Manual) and the manufacturer's installation instructions. The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13 and/or OSHPD. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - The Fig. 909 is the structural or transi- tional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO braced pipe attachment, Fig. 1000, 1001, 4A, 413 or 4L to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, pipe size and finish. Dimensions. Pipe Size A B H* Load Lb;. Lbs. w/Washer Wt./100 1 6 15/8 17/32 2015 2765 91 * Available with hole sizes to accommodate up to 3/4' fastener. Consult Factory. TOLCO® brand bracing components are desgined to be compatible Qfjj_Y with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.186.5266 wwwfolco.com ZURN® Model 350ADA Double Check Detector Assembly Application Designed for installation on water lines in fire protection sys- tems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350ADA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Horizontal & Vertical) ASSE® Listed 1048 AWWA Compliant C510 (with gates only), and C550 GSA® Certified B64.5 UL® Classified C-UL® Classified FM® Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA221-04M-2 (2 1/2" -8") Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backflow Assembly 3/411 Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved electrostatic epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners & Springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Features Sizes: 2 1/211*, 3"', 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged bolt pattern) ASME 1316.42 Class 150 *2 1/2" & 3" sizes use 4" body & reducer couplings Dimensions & Weights (do not include pkg.) WEIGHT MODEL 350ADA SIZE mm LESS SHUTOFF VALVES th OSY GATE VALVES FLANGED OSY GATE VALVES GROOVED kg BUTTERFLY VALVES FLANGED lbs. I kg BUTTERFLY VALVES GROOVED lbs. I kg 21/2 65 105 48 192 87 184 83 157 71 147 67 3 80 104 47 210 95 200 91 162 73 148 67 4 100 91 41 230 104 204 93 147 66 139 63 6 150 141 64 362 164 332 151 246 111 215 98 8 200 302 137 762 346 738 335 491 223 445 202 10 250 355 161 1024 464 902 409 628 285 1 570 259 LEAD FREE Sao NSF/ANSI (with OS&Y gates) (with BG valves) Options (Suffixes can be combined) - with flanged end OS & Y gate valves (standard) L - less shut-off valves (grooved body connections) LM - less water meter RM - with remote reading meter - with gallon meter (standard) CFM - with cu ft meter 0 CMM - with cu meter meter LI G - with grooved end connections LI FG - with flanged inlet connection and grooved outlet connection 0 P1 - with Post Indicator Gate Valves BG - with grooved end butterfly valves with integral supervisory switches BF - with flanged end butterfly valves with integral supervisory switches Accessories 0 Repair kit (rubber only) O Thermal expansion tank (Model XT) LI OS & Y Gate valve tamper switch (OSY-40) MODEL DIMENSION (approximate) 350ADA SIZE in mm A in I mm A WITH BUTTERFLY VALVES in I mm B LESS GATE VALVES in mm C in mm D in mm E OS&Y OPEN in I mm E OS&Y CLOSED in I mm E WITH BUTTERFLY VALVES in mm F in I mm G in mm 21/2 65 351/8 892 321/8 816 201/8 511 41/2 114 9 229 173/41 451 153/8 391 17 432 6 152 71/4 184 3 80 361/8 918 33 838 201/8 511 41/2 114 9 229 201/4 514 17 432 17 432 6 152 71/4 184 4 100 381/4 972 331/4 845 197/8 505 41/2 114 9 229 221/2 572 181/4 464 17 432 6 152 8 203 6 150 471/4 1200 401/4 1022 257/8 657 51/2 140 101/2 267 301/2 775 241/4 616 171/2 445 7 178 10 254 8 200 62 1575 55 1397 381/2 978 10 254 12 305 37 940 281/2 724 1615/16 430 81/2 216 11 279 10 250 645/8 1641 59 1499 38 1/2 978 10 254 12 305 455/8 1159 343/4 883 16 15/16 430 81/2 216 12 305 Attention: Model 350ADA (grooved body) and Model 350DA (flange body) have different lay lengths. Zurn Industries, LLC I Wilkins Rev.K Date. 12/19 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Document No. BF-35OADA In Canada I Zurn Industries Limited Patent No. 5, 913, 331 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 Product No. Model 350ADA www.zurn.com Pagel of 2 Flow Characteristics MODEL 350ADA 2 1/2",3" &4" (STANDARD & METRIC) FLOW RATES f/s) 12.6 25.2 37.9 ' Rated Plow (established by approval agencies) 50.5 104 a- 69 ul —J w cc 35 C)) W I U-— 0 0 0 200 400 600 800 FLOW RATES (GPM) MODEL 350ADA 6",8" & 10" (STANDARD & METRIC) FLOW RATES (Vs) 0.0 63.1 126.2 189.3 252.4 215 U) U) 10 0 —I Lu U) U) IL 0 1000 2000 3000 FLOW RATES (GPM) 1U4 0) 69 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. MODEL 350ADABG (Vertical Installation) Capacity thru Schedule 40 Pipe (GPM) Pipe size 5ft/sec 7.5ft/sec lOft/sec 15ft/sec 21/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8' 780 1169 1559 2339 10' 1229 1843 2458 3687 12' 1763 2644 3525 5288 PROTECTIVE MODEL 350ADA (Outdoor Installation) Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and sup- plied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backf low Prevention Assembly shall be a ZURN WILKINS Model 350ADA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zum Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 L N KING Viking Group, Inc. FABRICATION SERVICES * RIVERSIDE, CA WARNING FITTINGS ON ALL THREADED PIECES LESS THAN 4" LONG WILL BE HAND TIGHT. .. THANK YOU. VIKING FABRICATION SERVICES VFSRIVERSIDE@SUPPLYNET.COM PHONE: 951-656-3111 * FAX: 951-656-2606 MKI NG VIKING FABRICATION SERVICES LLC 1.0 WELDING A. GENERAL: All welding to follow procedures as set forth by VIKING FABRICATION SERVICES and will work to be in compliance with the following standards. American Welding Society Standard AWS B2.1. National Fire Protection Association Standard NFPA 13 "Installation for Sprinkler System?. National Fire Protection Association Standard NFPA SiB, "Standard for Fire Prevention in use of cutting welding processes". State, local and city codes. B. PROCEDURE: Prior to any welding or cutting in the welding fabrication shop, it's the responsibility of the welder to check all his equipment for safety and that any combustible materials within 35 feet if the operation is either removed or shielded. The general superintendent or the staff welding supervisor of the company confirms that prior to any operation, welding or cutting that there is adequate ventilation throughout the welding shop area and that all safety precautions are in compliance. All holes in piping required for welding of pipe-o-lets, threads-a-Lets or stock-o-lets, in lieu of tees, are to be cut with a plasma machine. The size of the hole is exactly the same diameter as the internal diameter (l.D.) of the approved UL Fitting. S. No fitting shall be modified whatsoever. The coupon and/or disk us the removed by magnet, completely removing any foreign objects from the pipe. The hole is then cleaned, removing any residue by means of a chipping hammer and file so as to guarantee a smooth bore and clean surface for welding. Fitting is then placed over the hole making sure it does not penetrate the internal diameter of the piping causing flow restrictions and then the fitting is leveled in both directions prior to tacking. One tack weld is then made and again fitting is leveled. When level, two (2) more tack welds are made, making three (3) tack welds in all and level checked again. UPDATED: 6/5/2020 Final welding of the fitting is then accomplished by using .035 or .045 gauge wire conforming to AWS specification no. ER07S-3 from AWS A5.18. The fitting is welded all around with a fillet weld. All slag and welding residue is removed and the weld inspected to ensure there is no visible slag or residue holes and there is a clear flow area. The staff welding superintendent inspects the welding fitting and flow are to verify that it meets the company requirements and specifications as well as codes. Stamping of the pipe with the welders identification imprint is then accomplished only after approval by the staffs welding superintendent. If the staffs welding superintendent disapproves of any impairment abnormally or encroachment of the weld, fitting or section of the pipe where the weld was performed. It is then destroyed by means of cutting it to guarantee the fitting and/or pipe cannot be used. The staff welding superintendent and the welder is responsible for the destroying the rejected pipe and welded fittings. Steel plates are not to be welded to the end of the pipe or fitting. Nuts, clips, eye rods, angle brackets or any other fasteners shall not be welded to the pipe or fitting. Torch cutting and welding shall not be permitted as a means of modifying or repairing sprinkler systems. 20 Welder's identification imprint to be S, J, R, or V C. INSPECTIONS: The general superintendent prior to any welded pipe leaving the welding shop ready to be taken to the field will check fittings and welds to ensure that all company procedures and standards satisfy code requirements and are in compliance with same. UPDATED: 6/5/2020 WELDER PERFORMANCE QUALIFICATION (WPQ) Welder's Name Saulo Solorzano Zamora Identification No. S Test Description WPS Followed VFS_WPS5010 Test Coupon 0 Production Weld Date Welded 2/7/2020 Specification & type/grade of base metal(s) A36 Thickness 1/2" Variables and Welding Variables (QW 350) Actual Values Range Qualified Welding Process(es) Type (i.e.; manual, semi-automatic used) Backing (with/without) Plate )( Pipe (enter diameter) - Base Metal Thickness Base meta lP Numberto P Number GMAW Semi-Automatic Without 8"x6 x0 5' 1/2" P1 P1 GMAW Semi-Automatic Without 1' 24" Pipe, All Plate 3/64"-UT P1th(uP151 P34 P41thruP49 Filler metal or electrode specification(s) (SFA) (info, Only) Filler metal or electrode specification (s) (Info Only) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW-S 3 layers min Yes X No Process 2 GMAW-G 3 layers mm X Yes No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GIAW, PAW, GMAW) Transfer mode (GMAW) A5.18 ER7OST6 F.6 1/8 INCH 1/8 INCH 2G N/A N/A Short Circuit & Spra F.6 INCH s 3/8 INCH Fillet: FM; Groove Pipe S 24": F, H N/A N/A All Results I Visual examination of completed weld SATISFACTORY Transverse face and root bends ET Longitudinal bends Side bends j3 Pipe specimen, macro test for fusion ED Plate specimen, macro test for fusion Type Result Type Result I Type Result SIDE BEND (QW- SATISFACTORY 161 1/QW 163) SIDE BEND (Q- SATISFACTORY 161.1/QW-163) Alternative Volumetric Examination Results N/A Fillet weld - fracture test N/A Length and percent of defects Fillet welds in plate jJ Fillet welds in pipe Macro examination Fillet size (in.) x Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crurnley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SZ2G_1 Welding supervised by Gonzalo Crux We certify that the statements in this record are correct and t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements of Section IX of th e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date 2 /iq /, Certified by - . '..., Lucas A Crumley Ayj cw 170704191 QCI EXP 7/1/2023 ........ 'T LucasACrumley OWl 17070491 001 EXP. 711/202( WELDER PERFORMANCE Welder's Name Saulo Solorzano Zamora No. Test Description WPS Followed VFS WPS 7002 Test Coupon Production Weld Date Welded 8/29/2019 Specification & type/grade of base metal(s) At5/A795 Thickness SH 7 Variables and Welding Variables (QW-350) Actual Values Range Ctuallfied Welding Process(es) Type (i.e.; manual, semi-automatic used) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) ( I n t o . O n l y ) Filler metal or electrode specification(s) (Info. O n l y ) Filler metal F-Number(s) Deposit thickness for each process Process 1. GMAW 3 layers min Fj Yes MR Position(s) Vertical progression (uphill or downhill) Use of backing gas (GTAW, PAW, GMAW) Transfer mode (GMAW) GMAW GMAW Semi-Automatic Semi-Automatic Without With/Without 4" 2 7/8" UT 5017 5017 P1_111 P3. *hru PtSF, 934, 943. thru P49 AS.18 ER70S-6 F6 No 1/4JNCH S 3/8 INCH Special Position spcui PosRion & Fiat for Fllfotg Both Both Globular Pulse Spray/Globular/Spray Results Visual examination of completed weld SATISFACTORY Transverse face and root bends U longitudinal bends U Side bends 1571 Pipe specimen, macro test for fusion El Plate specimen, macro test for fusion Type Result F Type Result Type Result Alternative Volumetric Examination Results N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects. NONE 0 Fillet welds in plate Dg Fillet welds in pipe Macro examination SATISFACTORY Fillet s i z e ( I n . ) 5/16 x 1/4 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no, SS,,47 Welding supervised by Gonzoló Cruz We certify that the statements in this record a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements of S e c t i o n IX of the ASME BOILER AND PRESSURE VESSEL C O D E & A W S B2.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date GMAW Semi-Automatic Without 1.25" Semi-Automatic GMAW SCH'7 1 $017 Pi-PI I Pa Thru PISF, P34, P41 Thru P49 F.6 114 INCH S 3/8 INCH Special Position spatial Position & Mat for Fiflets Both Both Globular i Pulse Spray/Globular/Spray WELDER PERFORMANCE QUALIFICAT I O N ( W P Q ) Welder's Name Saulo Soloriano Zamora Identification No. S - Test Description WPS Followed VFS_WPS_7004 0 Test Coupon ItZaj Production Weld Date Welded 8/28/2019 $peciflcatioa & type/grade of base metal(s ) A135-A795 Thickness SCH 7 Testing Variables and Qualification Limits Welding Variables (QW 350) Actual Values 1 Range Qualified Welding Process(es) Type (i.e.; manual, semi-automatic used) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (5 M ) ( i n f o . O n l y ) Filler metal or electrode specification(s) ( i n f o , O n l y ) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW Sayers mm [J Yes (XI No Position(s) Vertical progression (uphill or downhill ) Use of backing gas (GlAW, PAW, GMAW) Transfer mode (GMAW) Visual examination of completed weld SATISFACTORY 13 Transverse face and root bends U Longitudinal bends U Side bends Pipe specimen, macro test for fusion Plate specimen, macro test for fusion 1,24 Tvoe 1 Result I Type Result I Type I Alternative Volumetric Examination Results: Fillet weld - fracture test. SATISFACTORY Length and percent of defects NONE 0 Fillet welds in plate N Fillet welds in pipe Macro examination SATISFACTORY Fill e t s i z e ( i n . ) 7/32 x 1/4 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SS-1,7 Welding supervised by Gonzalo Cruz We certify that the statements In this record are correct and that the test c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requireme n t s o f S e c t i o n I X o f t h e A S M E BOILER AND PRESSURE VESSEL CODE & A W S 82.1. Specification for Welding Procedure and Performance Qualification . Date WELDER PERFORMANCE QUALIFICATION (WPQ.) Welder's Name Saulo Solorrano Zamora ldentIfiction No S Test Description WPS Followed VSWPS_7004 [J Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of base metal(s) A135-A795 Thickness 5C14 10 Testing Variables and Qualification Limits Weldjg Variables (QW 350) Actual Values I Ranac Qualified eldlng Process(es) Type (i.e.; manual, semi-automatic used) Backing (with/without) Plate Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) (Info. O n l y ) Filler metal or electrode specification(s) (Info. Onl y ) Filler metal F.Number(s) Deposit thickness for each process Process 1 GMAW 3 layers mm Yes MX No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GIAW, PAW, GMAW) Transfer mode (GMAW) GMAW GMAW Semi-Automatic Semi-Automatic Without - With/Without 1,2S" 3."-2 7/8k 50110 50110 P1-PS. P1thruP1517,P34,P41thruP49 ASiS £R70S-6 F.6 P.6 1/4 INCH S3/8 INCH S_pedal Position Spedal Poltlon & Flat for Fillets Both Both N/A N/A Globular Pulse Spray/Globular/Spray Results Visual examination of completed weld SATISFACTORY 0 Transverse face and root bends Lj Longitudinal bends 1J Side bends Pipe specimen, macro test for fusion [J Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results N/A Fillet weld fracture test SATISFACTORY Length and percent of defects NONE 0 Fillet welds In plate Wet welds In pipe Macro examination SATISFACTORY Fill e t s i z e ( i n . ) 1/4x: 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. Welding supervised by -Gonzalo Cruz We certify that the statements in this record a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements of Se c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 SpecifIcation for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date qJ( /240I q .. . Certified by •Z-..----:2- C" 17070491 QC1 EXP. 7/1r2020 %. rQt?' WELDER PERFORMANCE QUALIFIC A T I O N ( W Welders Name Saulo Solorzano Zamora identification No S Test Description WPS Followed VFSWPSJOO2 Test Coupon Production Weld Date Welded 9/28/019 Specification & type/grade of base metal(s) - A135/A795 Thickness SCH 10 Variables and Quaftflcation Limits Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (I.e.; manual, semi-automatic u s e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without - With/Without Plate Pipe (enter diameter) X 4' 2 7/0 - UT Base Metal Thickness - SCH 10 SCH 10 Base metal P-Number to P Number P1. P1 P1 thru P3.5F, P34, P41 thru P49 Filler metal or electrode speclflcatton(s) (SEA) (info. Only) A5.18 Filler metal or electrode specIfication(s) (Info Only) ER70S-G Filler metal F-Number(s) F.6 F.6 Deposit thickness for each process Process 1. GMAW 3 layers mm Yes No 1/4 INCH 3/8 iNCH Position(s) Special Position spec41 f'ostIon & rut for cWets Vertical progression (uphill or downhill) Both both Use of backing gas(GTAW, PAW, GM A W ) N/A N/A Transfer mode (GMAW) - Globular Pulse Spray/Globular/Spray Visual examination of completed wel d SATISFACTORY 0 Transverse face and root bands U Longitudinal bends 3J Side bends Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusion Alternative Volumetric Examination R e s u l t s : ______________ _ _ _ _ _ _ _ _ _ _ _ _ _ Fillet weld - fracture test SATISFACTORY length and percent of defects NONE J Fillet welds in plate Fillet welds In pipe Macro examination SATISFACTORY - Fillet abe (In,) 5/1$ x 9/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. Welding supervised by Gonzola Cruz We certify that the statements In this r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requireme n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure a n d P e r f o r m a n c e Q u a l i f i c a t i o n Organization Viking Fabrication Services Date 'k /1 / Zi..91 ' Certified by ' Lucas A Crimley CWI .17070491 QCI EXP. 7/112020 4J WELDER PERFORMANCE QUALIFICATION ( W P Q ) Welder's Name Saulo Solorzano Zamora Identification No. S Test Description WPS Followed VFS_WPSJOOZ 0 Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of base metal(s) A53. Thickness SQl 40 Variables and Qualification Urnits Welding Process(es) Type (i.e.; manual, semi-automatic use d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SE A ) ( i n f o . O n l y ) Filler metal or electrode specification(s) (Info. Only) Filler metal F-Number(s) Deposit thickness for each process Process I GMAW 3 layers min f7 Yes MX No Position(s) Vertical progression (uphill or downh i l l ) Use of backing gas (GTAW, PAW, GMAW) Transfer mode (GMAW) Actual Values e Qualified GMAW GMAW Semi-Automatic Without 4', SCH4O SCH4O PI-Pi P1 thru PISF. P34, P41 thru P49 AS.18 ER70S-6 F.6 1 F6 1/4 INCH s 3/8 INCH Special Position Speci Position & Flat for Fillets Both Both N/A N/A Globular Pulse Spray/Globular/Spray- I Results Visual examination of completed wel d SATISFACTORY . 0 Transverse face and root beads U LongItudinal bends U Side bends Pipe specimen, macro test for fusion [3 Plate specimen, macro test for fusio n Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE D Fillet welds in plate N Fillet welds in pipe Macro examination SATISFACTORY F i l l e t s i z e ( i n . ) 5/16 x 9/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no.. SS4_40 Welding supervised by . . Gonale Cruz We certify that the statements In thi s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d w e l d e d , a n d tested in accordance with the requiremen t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure and Perf o r m a n c e Q u a l i f i c a t i o n . Organization Viking Fabrication Services Date 4 116 -'Z..---- --' tuca5ACrumIey . Ay CWI. 17070491. WELDER PERFORMANCE QUALIFICATI O N ( W P Q Welder's Name Saulo Solorzano Zamora identification No S Test Description WPS Followed VFSWPS_7004 Test Coupon Z Production Weld bate Welded 8/28/2019 Specification & type/grade of base metal(s) A135-A795 Thickness SCH 40 Test$nR Variables and Qualification Lim i t s Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (I.e.; manual, semi-automatic us e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 1.25" 1"-2 7/8" Base Metal Thickness SCM 40 SCM 40 Base metal P-Number to P-Number P1-PI. P1 thru l'15F P34 P41thru P49 filler metal or electrode specification(s) (SEA) ( I n f o . O n l y ) A5.18 Filler metal or electrode specification(s) (info. Only) ER70S-6 Filler metal F-Number(s) F.6 F.6 Deposit thickness for each process Process 1 GMAW 3 layers mm [J Yes No 1/6 INCH 318 INCH Position(s) Special Position Special Position & Rat for fillets Vertical progression (uphill or downhill) Both Both Use of backing gas (GIAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Globular Pulse SpraGiobuiar/Spray Results Visual examination of completed weld SATISFACTORY El Transverse face and root bends Lj Longitudinal bends Lj Side bends Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fu s i o n F 'type I Result I Type Result Type Result Alternative Volumetric Examination R e s u l t s : N/A Fillet weld - fracture test SATISFACTORY Length and percent defects NONE Fl Fillet welds In plate Dg Fillet welds In pipe Macro examination SATISFACTORY F i l l e t size (in.) 1/4 - x 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley - Laboratory test no. SS_1.40 Welding supervised by Gonzalo Cruz We certify that the statements In this record are co r r e c t a n d t h a t t h e t e s t coupons were prepared, welded, and tested in accordance with the requirements o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E l . C O D E & A W S 52.1 Specification for Welding Procedure and Performa n c e Q u a l i f i c a t I o n . - Organization Viking Fabrication Date 41 IIC /o J.?WA LucesACru in" lay' AW ?CWI 1707041 WELDER PERFORMANCE QUALIFICATION (WP Welders Name Jose Guiterrer identification No, J Test Description WPS Followed VPS_WPS_7002 Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of base metal t s ) A135/A795 Thickness 501 7 Testing Variables and Qualificatio n U m i t s Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automati c u s e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 4 2 7/8' - UT Base Metal Thickness SQl 7 Base metal P-Number to P-Number P2.-Pi Pt thru P15I, P34, P41 thru P49 Filter metal or electrode specification(s) (SFA) (Info O n l y ) AS 18 Filler metal or electrode specification(s) (Info Only) ER70S 6 Filler metal F Number(s) F,6 F.6 Deposit thickness for each process Process 1 - GMAW 3 layers mi El n Yes No 1/4 INCH 3/8 INCH Position(s) Special Position special PosiuOn & fist for filets Vertical progression (uphill or do w n h i l l ) Both Both Use of backing gas (GTAWI PAWS GMAW) N/A N/A Transfer mode (GMAW) Globular Pulse Spray/Globular/Spray Results Visual examination of completed w e l d SATISFACTORY 0 Transverse face and root bends [J Longitudinal bends Li side bends Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type - Result Alternative Volumetric Examination RSUIt5 KIM Fillet weld fracture test SATISFACTORY Length and percent of detects NONE 0 Fillet welds in plate Fillet we1d5 in pipe Macro examination SATISFACT O R Y F i l l e t s i z e ( i n . ) 9/32 x 11/32 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. Welding supervised by Gonzola Cruz We certify that the statements in t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requireme n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1. Specification for Welding Procedure a n d Performance Qualification. Organization Viking Fabrication Services Date q Jib f"up Certified by • ••••• Lucas A CrurnIi'iL CWI 11070491 v. :0C1 xp. WELDER PERFORMANCE QUALIFIC A T I O N ( W P Q Welder's Name Jose Guiterrez Identification No Test Description WPS Followed VFS_WPS_7004 D Test Coupon Production Weld Date Welded 8/28/2019 LCU Specification & type/grade of base meta l ( s ) A135-A795 Thickness 501 7 Testing Variables and Qualification Umits Variables Welding Process(es) Type (i.e.; manual, semI-automatic u s e d ) Backing (with/without) Plate Pipe (enter diameter) X Base Metal Thickness - Base metal P-Number to P-Number Fillet metal or electrode specification(s) (SFA) (Info. Only) Filler metal or electrode specification(s) ( I n f o . O n l y ) Filler metal F-Number(s) Deposit thickness for each process Process I. GMAW 3 layers min 0Yes 0No Position(S) Vertical progression (uphill or downh i l l ) Use of backing gas (GTAW. PAW, .G M A W ) Transfer made (GMAW) Actual Values GMAW Semi-Automatic Without 1.25" SCH7 Pi-pi AS.18 ER7OS-6 F.6 1/4 INCH - Special Position Both N/A Globular GMAW Semi-Automatic With/Without SCH7 P1thruPlS5. P34, P41. thru P.6 13/8 INCH Spiclal Position & dat for Ft Both N/A Pulse Spray/Globular/S Visual examination of completed w e l d SATISFACTORY [J Transverse face and toot bends [J Longitudinal bends U Side bends Pipe specimen macro test for fusion Plate specimen, macro test for fus i o n Result Alternative Volumetric Examinatio n R e s u l t s N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE U Fillet welds In plate N Fillet welds in pipe Macro examination SATISFACTO R Y F i l l e t s i z e ( i n . ) 1/4 x 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. __________ Welding supervised by Gonzalo Cruz We certify that the statements in t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the require m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2,1 Specification for Welding Procedure and Performance Q u a l i f i c a t i o n . Organization Viking Fabrication Services Date q / 1i I24'L'1 . . 9,tuca6 A Cnimley .;•' N*WSP. CW .17071.1491 ::N ...... ..•, Actual Values GMAW Semi-Automatic Without 1,25" SCH 10 Pi-Pi A5.18 ER7OS-G F.6 Range Qualified GMAW Semi-Automatic With/Without 1".27/8't SCH 10 P1 thru P15, P34, P41 thru F.6 3/8 INCH Special Position I scii 001tios & flat fcw met, WELDER PERFORMANCE QUALI F I C A T I O N ( W P Welder1s Name - Jose Guiterrer Identification No .1 Test Description WPS Followed VFS,WPS_7004 Test Coupon Production Weld Date Weld e d 8/28/019 Specification & type/grade of bas e m e t a l ( s ) A135-A795 Thickness SCH 10 Variables and Qualification Umit s Variables Welding Process(es) Type (i.e.; manual, semi-automat i c u s e d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Nu m b e r filter metal or electrode specification(s) (SFA) (info. Only) Filler metal or electrode specificati o n ( s ) ( i n f o , Only) Filler metal F-Number(s) Deposit thickness for each pro c e s s Process 1 GMAW 3 layers min (:1 Yes Ej No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GIAW, PAW , G M A W ) Transfer mode (GMAW) Globular Visual examination of completed w e l d SATISFACTORY C] Transverse face and root bends U Longitudinal bends UI Side bends Pipe specimen, macro test for fusi o n 13 Plate specimen, macro test for fusion I Type { Result I Type I Result Type Result Alternative Volumetric Examin a t i o n R e s u l t s N/A Fillet weld fracture test SATISFACTORY Length and percent of defects NONE Fillet welds In plate Fillet welds in pipe C] Macro examination SATISF A C T O R Y F i l l e t slze (in.) 1/4 x 5116 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. 16_LI0 Welding supervised by Gonz&o Cruz we certify that the statements I n t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requi r e m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 62.1 Specification for Welding Procedure and Performance Qualficotlon. Organization Viking Fabrication Services Date R/110 4011 LucuACnnnley ewl '11170704911 .:. WELDER PERFORMANCE QUAL I F I C A T I O N fWPQ1 Welder's Name Jose Guitrrez Identification No. j Test Description WPS Followed VF4.WPSJO02 Test Coupon ZProduction W e l d D a t e W e l d e d 8/28/2019 SpecIfication & type)grade of base m e t a l ( s ) A135/A795 Thickness SCH 10 Testing Variables and Qualificati o n L i m i t s Welding Variables (QW.3SO) Actual Values Range Qualified Welding Processes) GMAW GMAW Type (i.e.; manual, semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 4'I 2 7/8 UT Base Metal Thickness 504 10 SCH 10 Base metal P-Number to P-Nu m b e r P141 Pt thru Pt5F, P34 P43.thru P49 Filler metal or electrode specification ( s ) ( S F A ) ( I n f o O n l y ) AS 18 Filler metal or electrode specificatio n ( s ) ( i n f o O n l y ) ER70S 6 Filler metal F-Number(s) F.6 F.6 Deposit thickness for each pro c e s s Process 1 GMAW 3 layers min Yes ED No 1/4 INCH 9 3/8 INCH Position() Special Position Special Pw.itlon & Flat tar ruit, Vertical progression (uphill or d o w n h i l l ) Both Both Use of hacking gas (GTAW PAW, G M A W ) N/A N/A Transfer mode (GMAW) Globular Pulse Spray/Globular/Spray Results Visual examination of completed weld SATISFACTORY 0 Transverse face and root bends U Longitudinal bends Li Side bends Pipe specimen macro test for fusion Plate specimen, macro test for f u s i o n Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE EJ Fillet welds in plate M Fillet welds In pipe Macro examination SATISFAC T O R Y F i l l e t s i z e ( i n . ) 5/16 x 3/8 Concavity or convexity (in.) Other Tests - Film or specimens evaluated by - Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no Welding supervised by Gonzola Cruz We certify that the statements in thi s r e c o r d a r e c o r r e c t a n d t h a t the test coupons were prepa r e d w e l d e d , a n d tested in accordance with the requ i r e m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & AWS B2.1 Specification for Welding Procedure an d Performance Quolificotion. Organization Viking Fabrication Services Date 4 / (6 Iii.'i q Lucas CrumI ). CWsiiioøi WELDER PERFORMANCE QUALI F I CATION (wPa) Welders Name Jose Gulterraz - - Identification No.,- .1 Test Description WPS Followed VFSWPS_7004 Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of b a s e m e t a l ( s ) A135-A795 Thickness SCM 40 Testing Variables and Qualification Limits Welding Variables (QW'350) Actual Values Range Quail led Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automa t i c u s e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 1.25*1 -2 7 1 Base Metal Thickness SCM 40 SCM 40 Base metal P-Number to P Nu m b e r PI-PI Pt thru P1SF P34 P41 thni P49 Filler metal or electrode specificati o n ( s ) ( S F A ) ( I n f o , O n l y ) AS.18 Filler metal or electrode specificati o n ( s ) ( i n f o . O n l y ) R7OS6 Filler metal F-Number(s) F.6 F.6 Deposit thickness for each proce s s Process 1 GMAW 3 layers min 0 Yes M No 1/4 INCH S 3/8 INCH Position(s) Special Position 5peds outIon a flat for flUeta Vertical progression (uphill or downhill) Both Both Use of backing gas (GTAW, PAW, G M A W ) N/A N/A Transfer mode (GMAW) Globular - Pulse Spray/Globular/Spray Results Visual examination of complete d w e l d SATISFACTORY Transverse face and root bends U Longitudinal bends U Side bends Pipe specimen, macro test for, f u s i o n 0 Plate specimen, macro test for f u s i o n Result Alternative Volumetric Examinat i o n R e s u l t s N/A Fillet weld fracture test SATISFACTORY Length and percent of defects NONE Fillet welds In plate Z Fillet welds in pipe Macro examination SATISFACT O R Y F i l l e t s i z e ( i n . ) 5/16 x 5/16 Concavity or convexity (in,) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. JG,,,,1_40 Welding supervised by Gonzalo Cruz We certify that the statements In t h i s r e c o r d are correct and that the test coupons were p r e p a r e d , w e l d e d , a n d tested in accordance with the requ i r e m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.3. Specification for Welding Procedure and Performance Q u a l i f i c a t i o n . . Organization Viking Fabrication Services Date //( Cartifl F rtual Values GMAW rnI.Automat Without 4" SCH 40 Pi-Pi AS.18 ER7OS-6 Range Qualified GMAW Semi-Automatic With/Without 27/80 -UT SCH 40 Pt thru Pt5F. P34. P41 thru P49 F6 F6 1/4 INCH i5 3/8 INCH Special Position Special Position & sat for row, Both Both Pulse WELDER RMNCEQUAUFICATION (WPQ) Welder's Name Jose Guiterrez Identification No I Test Description WPS Followed VISWPSJOOZ D Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of base met a l ( s ) A53 Thickness SCH 40 Variables and Qualification Limits Variables Welding Process(es) Type (i.e., manual, semi-automatic u s e d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-N umber to P-Number Filler metal or electrode specification(s) ( $ F A ) ( I n f o . O n l y ) Filler metal or electrode specification(s) ( i n f o . O n l y ) Filter metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 layers Wn [J Yes [] No Position(s) Vertical progression (uphill or downhi l l ) Use of backing gas (GTAW, PAW, G M A W ) Transfer mode (GMAW) Visual examination of completed we l d SATISFACTORY EJ Transverse face and root bends Li Longitudinal bends U Side bends Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusi o n IAQJ Result Alternative Volumetric Examination R e s u l t s N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE 0 Fillet welds In plate LCJ Fillet welds in pipe Macro examination SATISFACTORY Fill e t s i z e ( I n . ) 9132 x 11/32 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducte d b y Lucas Crumley Laboratory test no. ____________ Welding supervised by Gonzoia Cruz We certify that the statements In t h i s r e c o r d are correct and that the test coupons were prepar e d w e l d e d , a n d tested In accordance with the require m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L CODE & AWS 82.1 Specification for Welding Procedure a n d Performance Qualification. Organization Viking Fabrication Services Date ctfI /ual't ry V 6 Lucas A Crumley V ..CWI 17070495 WELDER PERFORMANCE QUALIFICATIO N ( w p o ) Welder's Name Robert Carrillo Identification No R - - Test Description WPS Followed VFS WPS 3004 Test Coupon IeN Production Weld Date Welded 7/2/2019 Spedfication & typeJgrde of base metal(s) A135-A795 Thickness SCH 7 Testing Variables and Qualification Umits Welding Variables (QW 350) Actual Values Range Qualified Welding Process(es) GMAW Type (i.e.; manual, semi-automatic used) Backing (with/without) Without Plate - Pipe (enter diameter) X L2S Base Metal Thickness SCH7 Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) (Info. Only) AS.18 Filler metal or electrode specification(s) (Info. Onl y ) ER7OS-6 Filler metal F-Number(s) F.6 Deposit thickness for each process Process I - GMAW 3 layers min 0 Yes RXNo 1/4 INCH Position(s) Special Position Vertical progression (uphill or downhill) Both Use of backing gas (GTAW, PAW, GMAW) N/A Transfer mode (GMAW) Short Circuit GMAW SCH7 1SF, P34, P41 thru P49 F.6 3/8 INCH Pcition & fiat for 0014ts Both - N/A Short Orcult Semi-Automatic I Semi-Automatic Results Visual examination of completed weld SATISFACTORY Transverse face and root bends Lj Longitudinal bends Lj Side bends k:zj Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusion Ivue I Result 1 Tvoe I Result I Type I Result I Alternative Volumetric Examination Result s : Fillet weld - fracture test SATISFACTORY Length and percent of defects 13 Fillet welds In plate j Fillet welds in pipe Macro examination SATISFACTORY Fil l e t s i z e ( I n . ) 7/32 x 1/32 Other Tests NONE Concavity or convexity (in.) Film or specimens evaluated by - Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RCI. Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements of Secti o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date /tc.q Certified by ..... . . . . . , . *M OiI ;cs EXP. 71J200 WELDER PERFORMANCE QUALIFICATION ( W P Q ) Welder's Name Robert Carrillo Identification No. R - Test Description WPS Followed VFSWPS 3002 U Test Coupon M Production Weld Date Welded 7/2/2019 LCJ Specification & type/grade of ba s e m e t a l ( s ) A135/A795 Thickness 501 7 Testing Variables and Qualification Umlts Welding Variables (QW-SO) ActUal Values Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X — 4" 2 7/8" UT Base Metal Thickness SCH 7 SCM 7 Base metal P-Number to P-Number PI.-PI. - Pt thru ?15F. P34. P41 thai P49 Filler metal or electrode specification(s) (SFA) (inf o . O n l y ) A5,18 Filler metal or electrode specification(s) (into. Only) ER705-6 Filler metal F Number(s) F.6 F.6 Deposit thickness for each process Process 1 GMAW 3 layers min Yes FXJ No 1/4 INCH 3/8 INCH Position(s) Special Position SpeUI Positioa & Flat by Fillets Vertical progression (uphill or downhill) Both Both Use of backing gas (GTAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Short Circuit - Short Circuit Results Visual examination of completed weld SATISFACTORY U Transverse face and root bends [J Longitudinal bends (J Side bends Pipe specimen, macro test for fusion 13 Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE 11 Fillet welds in plate Fillet welds in pipe Macro examination SATISFACTORY Fill e t s i z e ( i n . ) 5/16 x 9/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. flC4.1 Welding supervised by GonzotaCruz We certify that the statements in this reco r d a r e correct and that the test coupons were prepared, w e l d e d , a n d tested in accordance with the requirements of Se c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 SpecIfication for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date i/f: / LtI - — tum A ciw Cwj iioj 001 EXP . WELDER PERFORMANCE QUALIFI C A T I O N ( W P ) Welder's Name Robert Carrillo Identification No. R Test Description WPS followed VFSWPS,,,3004 Test Coupon Production Weld Date Welded 7/2/2019 - Specification & type/grade of base metal(s) A135-A795 Thickness SCH 10 Variables and Qualification Limits Variables Welding Process(es) Type (i.e.; manual, semi-automatic u s e d ) Backing (with/without) Plate Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) ( S F A ) (info. Only) Filler metal or electrode specification(s ) ( i n f o , O n l y ) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 layers min f7Yes M No Actual Values Range Qualified GMAW GMAW Semi-Automatic Semi-Automatic Without With/Without 1.25' 1"-27/8" SCH 10 50110 P3.-Pi P1 thru PIS. P34, P41 thru P49 AS.18 ER7OS-6 F6 F6 1/4 INCH 1318 INCH Special Position 5pecial PeiUo) & Flat for Mats Vertical progression (uphill or downh i l l ) Both Both Use of backing gas (GTAW, PAW, GMA W ) N/A N/A Short. Short Circuit Position(s) Transfer mode (GMAW) Results Visual examination of completed wel d SATISFACTORY El Transverse face and root bends U Longitudinal bends I,J Side bends Pipe specimen, macro test for fusio n El Plate specimen, macro test for fusio n kahl Alternative Volumetric Examinatio n R e s u l t s : N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE Fillet welds in plate Z Fillet welds in pipe Macro examination SATISFACTORY Fillet size (in.) 7/32 x 7/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services - Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC2 Welding supervised by Gonzalo Cruz We certify, that the statements in this record ar e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requi r e m e n t s o f S e c t i o n IX of the ASME BOILER AND PRESSURE V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performnnce 0 u a 1 1 1 c o t 1 o n . Organization Viking Fabrication .Services I ucu A ' ' CWI t1yt4G1 .'CI cP.7I1ii0ZJ WELDER PERFORMANCE QUALIFICATION t W P Q Welder's Name Robert Carrillo identification No R lest Description WPS Followed VFS_WPS_3002 Test Coupon Production Weld Date Welded 7/2/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 10 Testing Variables and Qualification Limits Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automatic used) Semi Automatic Semi Automatic Backing (With/without) Without With/Without Plate Pipe (enter diameter) X - 4" 2 7/8" UT Base Metal Thickness SCH 10 SCH 10 Base metal P Number to P-Number P1-PI. P1 thru PISF P34 P41 thruP49 Filler metal or electrode specification(s) (SFA) (Info. Only) A5.18 Filler metal or electrode specification(s) (Info Only) ER705 6 Filler metal F-Number(s) F.6 F S Deposit thickness for each process Process 1 GMAW 3 layers mi 11 n Yes El No 1/4 INCH 6 3/8 INCH Position(s) Special Position 5peiat Position & dat fr filtts Vertical progression (uphill or downhill) Both Both Use of backing gas (GTAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Short Circuit Short Circuit Results - Visual examination of completed weld SATISFACTORY D Transverse face and root bends Li Longitudinal bends jJ Side bends Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result - Type Result Type Result AIernaT.ive voiumetric txaminaion rcesuirs; Fillet weld fracture test SATISFACTORY Length and percent of defects NONE U Fillet welds in plate M Fillet welds in pipe Macro examination SATISFACTORY Fillet s i z e ( i n . ) 3/8 x 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no, RC4.2 Welding supervised by Gonzota Cruz We certify that the statements in this record a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section lx of the ASME BOILER AND PRESSURE V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Qualification, Date ¶16/ Organization ing Fabrication Services .CWI 170 rPc It gXp WELDER PERFORMANCE QUALIFICATION (WP Q Welders Name Robert Carrillo Identification No. It Test Description WPS Followed VFS,WPS_3004 Test Coupon Production Weld Date Welded 7/2/201 Specification & type/grade of base metal(s) A135A79S Thickness SCH 40 Testing Variables and Qualification Limits Welding Variables (QW-350) Actual Values - - Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi automatic used) Semi Automatic Semi Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X 1.25" 1"2 7f8 Base Metal Thi - ckness SCH 40 SCH 40 Base metal P-Number to P-Number Pi-PI. - P. thru PiSF, P34, P41 thru P49 Filler metal or electrode specification(s) (SEA) (Info O n l y ) AS 18 Filler metal or electrode specification(s) (info, Only) ER70S-6 Filler metal F Number(s) F.6 F,6 Deposit thickness for each process Process I GMAW 3 layers min nYes No 1/4 INCH 3/8 INCH Position(s) Special Position Special P013tion & flat Of IIIeI Vertical progression (uphill or downhill) Both Both Use of backing gas (6TAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Short Circuit Short Circuit Results Visual examination of completed weld SATISFACTORY 0 Transverse face and root bends Li Longitudinal bends Lj Side bends Pipe specimen, macro test for fusion J Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects - NONE Fillet welds in plate Fillet welds in pipe Macro examination SATISFACTORY Fillet size ( i n . ) 1/3 x 1/3 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC3 Welding supervised by Gonzalo Cruz We certify that the statements in this record are c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performan c e Q u a l i f i c a t i o n . Organization Viking Fabrication Services Date '/i. Hoo Certified by Lucas A Cmmla 4'Ag'cm, 1107041' DCI EXP, iitmc ,i .. .t4. I WELDER PERFORMANCE QUALIFICATION (WPQ) Welders Name Robert Carrillo Identification No R — Test Description WPS Followed VFSWPS_3002 Test Coupon t7 Production Weld Date Welded 7/22/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 40 Variables and Qualification Welding Variables (c1W-350) Actual Values Range Qualified Weldingprocess(es) GMAW GMAW Type (i.e.; manual, semi-automatic used) Semi Automatic Semi Automatic Backing (with/without) Without With/Without Plate - Pipe (enter diameter) X 4" 2 7/8w UT Base Metal Thickness 5C14 40 SCH 40 Base metal P-Number to P-Number P1-Pi P1 thru P15F. P34, P41 thru 949 Filler metal or electrode specification(s) (SEA) (Info. Onl y ) A5.18 Filler metal or electrode specification(s) (Info. Only) ER705-6 filler metal f-Number(s) - F6 Deposit thickness for each process Process I GMAW 3 layers mm Yes No V4 INCH 3/8 INCH Position(s) Special Position spEial PojItioi fli br Fillets Vertical progression (uphill or downhill) Both Both Use of backing gas (GTAW, PAW, MAW) N/A N/A Transfer mode (GMAW) Short Circuit Short Circuit Visual examination of completed weld SATISFACTORY U Transverse face and root bends [J longitudinal bends U Side bends Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results N/A Fillet weld fracture test SATISFACTORY length and percent of defects NONE 0 Fillet welds in plate Fillet welds In pipe Macro examination SATISFACTORY Fillet size ( i n . ) 5/16 x 3/8 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services - Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC4.3 Welding supervised by Gonzola Cruz We certify that the statements in this record are c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements of Section IX o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 821. Specification for Welding Procedure and Performance QualIfication. Organization Viking Fabrication Services Date !7'j Certified by I - - - cys7 CWI 17o EXP. WELDING OPERATOR PERFORMANCE QUALiFICATION (WPQ) Welders Name Seqouia Stueve Identification No. S Sample Number S_A1J Test Descri WPS Followed VFS_WPS1OO1 HTest Coupon j Production Weld Date Welded 12/5/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 7 Base Metal P-Number 1 to P-Number 1 Position(s) S.P. Pipe Schedule 7 Pipe Diameter 1.25" Outlet Diameter 0 5 Filler metal (SFA) specification #5 18 Fuller metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Welding Equipment I Weldi Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side Actual Values NAP GMAW DIRECT OFF S.P, WITH SINGLE Range Qualified NAP/VFLEX GMAW DIRECT OFF S.P,, F. WITH OR WITHOUT SINGLE_____ Results I Visual examination of completed weld Satisfactory 0 Transverse face and root bends [_J Longitudinal bends J Side bends -/ J Pipe specimen, macro test for fusion 11 Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld -fracture test N/A Length and percent of defects 13 Fillet welds in plate A I Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 1/8 x 7/32 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no S_A1_7 Welding supervised by GonzatoCruz - We certify that the statements in this record are correct and that the t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILE R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Qualif i c a t i o n , Organization Viking Fabrication Services Date I /I /v9io Certified by Lucas A Crumley AVis cwi 17070491 OCI EXP. 7/112020 . . . WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Seqoula Stueve Identification No. S Sample Number SA1j0 Test WPS Followed VFS_WPS_1001 - - - U Test Coupon J Production Weld Date Welded 12/5/2019 - Specification & type/grade of base metal(s) A135 95 Thickness SCH 10 Base Metal P-Number I to P-Number Position(s) S.P. Pipe Schedule: 10 Pipe Diameter: 1.2S' Outlet Diameter: 0.5" Filler metal (SFA) specification A5.18 Filler metal or electrode. classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Weldin g E q u i p m e n t I Welding Variables (QW-361.2) - ............Actual Values Range Qualified Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side NAP NAP/VFLI GMAW GMAW DIRECT DIRECT OFF OFF S.P. S.P., F. WITH I WITH OR WITHOUT SINGLE -. --. SINGLE Results Visual examination of completed weld . . Satisfactory Transverse face and root bends U Longitudinal bends U . Side bends E Pipe specimen, macro test for fusion 1:1 Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld - fracture test N/A Length and percent of defects D Fillet welds in plate LJ Fillet welds in pipe Macro examination Satisfactory Fillet size (in) 1/8 x 5/32 Concavity or convexity (in) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no. S_A1..lci Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the te s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILE R A N D P R E S S U R E V E S S E L C O D E & A W S 132.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date I J -/7pi, Certified by .----: LucasACrum'oy s cwi 17070491 4iK .''QCI EXP. . . . -•.... . . .. .•I .... •., ft . WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Seqoula Stueve Identification No. S Sample Number SA1_40 - - - Test Description WPS Followed VFSWP5j001 Lj Test Coupon jj Production Weld Date Welded 12/5/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 40 Base Metal P-Number 1 to P-Number I Position(s) S.P. Pipe Schedule: 40 Pipe Diameter: 1.25' Outlet Diameter: 0.5" Filler metal (SFA) specification AS, 18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (OW 361 2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VELEX Welding Process GMAW GMAW Director Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. S,P., F. Backing.(with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results 1 Visual examination of completed weld Satisfactory U Transverse face and root bends [J Longitudinal bends 1J Side bends 0 Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusion Type - Result Type 1 Result Type Result Alternative Volumetric Examination Results: Fillet weld - fracture test N/A Length and percent of defects Fillet welds In plate LXJ Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 5/32 x 5/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. $_A1_40 Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASM E BO I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure and Performance Qualific a t i o n . Organization Viking Fabrication Services Date I /_J-w Certified by cd6 ..A.2'-'i ri...... r\•! A CWI 17070491 QCI. • I I l ......................... .. ., WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No. V Sample Number RV1_7A Test Description WPS Followed VFSWPSJ001 L_J Test Coupon [j Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SO-I 7 Base Metal P-Number 1. to P-Number 1 Position(s) S,P, Pipe Schedule: 7 Pipe Diameter: 1.25" Outlet Diameter 0.5" Filler metal (SFA) specification AS 18 Filler metal or electrode classification ER70S 6 Testing Variables and qualification Limits When Using Machine Welding Equipment Welding Variables (QW-3611) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. S.P., F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends [_j Longitudinal bends [J Side bends 0 Pipe specimen, macro test for fusion EJ Plate specimen, macro test for fusion. Type Result Type Result Type Result Aiternative Volumetric Examination Results: Fillet weld - fracture test N/A Length and percent of defects El Fillet welds in plate L?IJ Fillet welds in pipe Macro examination Satisfactory Fillet size (in:) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RV1JA Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepa r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSU R E V E S S E L C O D E (2019 Edition) & AWS B21 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date 5 /74 ho.a Certified by -'-------- ., I.,. .1iA Crui: ,CWI. l7O741, C1 E P 111/203 It I 1 WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No V Sample Number RV3_7A Test Descri WPS Followed VFS_WPS_1001 HTestcoupon [j Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 7 Base Metal P-Number 1 toP-Number 1 Position(s) S.P. Pipe Schedule: 7 Pipe Diameter: 3" Outlet Diameter: 13" Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S 6 Testing Variables and Qualification Limits When Using Machine Welding Equipment I Welding Variables (QW 361 2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S P S P F Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends Lj Longitudinal bends (J Side bends J Pipe specimen, macro test for fusion TJ Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld -fracture test N/A Length and percent of defects U Fillet welds in plate UX Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/15 Concavity or convexity (In.) - Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RV3_7_A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSU R E V E S S E L C O D E 2019 Edition) & AWS 82.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date f14 Certified by ' Lucy A thn'y CIA/I 17(j1491 WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welders Name Ramon Vazquez Identification No. V Sample Number RV1j0_A Test Description WPS Followed yES WPS 1001 [J Test Coupon 11 AvJ Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 18 Base Metal PNumber 1 to P-Number i Position(s) S,P Pipe Schedule 10 Pipe Diameter 1.2F Outlet Diameter 0.51 Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic JointTracking OFF OFF Position(s) S.P. S.P., F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends j Longitudinal bends U Side bends Pipe specimen macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects D Fillet welds in plate LXj Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley - Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no RV110A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepared, w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CO D E (2019 Edition) & AWS B21 Specification for We/ding Procedure and Performance Qualification. Organization Viking Fabrication Services Date Certified by ;•—'i:;7'— —2"' 11 :.i07O-91 - fI•''. .J- .,r) j .,. . - -'' .: :-.,., WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welders Name Ramon Vazquez Identification No. V Sample Number RV3j0—A Test Description WPS Followed VFSWPS 1001 U Test Coupon (j Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH10 Base Metal P-Number 1 to PNumber 1 Position(s) S.P. Pipe Schedule: 10 Pipe Diameter: 3' Outlet Diameter: 1.5' Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S6 Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. 5.P., F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends U Longitudinal bends j Side bends El Pipe specimen, macro test for fusion J Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects ED Fillet welds in plate EFillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RV310..A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepared, welded, and tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE (2019 Edition) & AWS B2,1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date ¶ fl%f-,, Certified by C-- ... . Liic48 'A Crurnley, w Aws ;CWf1707041 WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No V Sample Number RV140A Test Description WPS Followed VFSWPS 1001 U Test Coupon Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 40 Base Metal P-Number I to P-Number 1 Position(s) SP Pipe Schedule: 40 Pipe Diameter: 1.25 Outlet Diameter: 0.5' Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S 6 Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. S.P,, F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory 0 Transverse face and root bends Li longitudinal bends [J Side bends El Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld -fracture test N/A Length and percent of defects El Fillet welds in plate [J Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RV1_40_A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepared, welded, and tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE (2019 Edition) & AWS B2.1Specificotion for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date c/i. f-zo Certified by runi oil, - , , AWS C(P.V1/203 I WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welders Name Ramon Vazquez Identification No V Sample Number RV3.40_A Test Descriotion Specification & type/grade of base metal(s) A135/A795 Thickness Base Metal PNumber 1 to PNumber 1 Po5ition(S) Pipe Schedule 40 Pipe Diameter 311 Outlet Diameter 1.511 Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S 6 Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (QW-361.2) Actual Values I Range Qualified Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side NAP (3MAW DIRECT OFF S.P. WITH SINGLE NAP/VFLEX GMAW DIRECT OFF S.P., F. WITH OR WITHOUT SINGLE [ Results I Visual examination of completed weld Satisfactory Transverse face and root bends Li Longitudinal bends U Side bends El Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld - fracture test N/A Length and percent of defects El Fillet welds in plate UXFillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crurnley Laboratory test no. RV340A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were pre p a r e d , w e l d e d a n d tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VES S E L C O D E (2019 Edition) & AWS B2.1 Specification for Welding Procedure and Performance Qualificatio n . Organization Viking Fabrication Services Date ç/-t/1 Certified by -_-_-___m .'. - dr Ltas A trumlny AWS 11.. ,.• .. . ..........' .* WPS Followed VFSWPS_1001 Test Coupon Production Weld Date Welded 4/24/2020 SCH4O S.P.