HomeMy WebLinkAbout2501 GATEWAY RD; BLDG 12; FPC2018-0069; Permit("'City of Carlsbad Print Date: 02/15/2022 Job Address: 2501 GATEWAY RD, CARLSBAD, CA Permit Type: FIRE-Construction Commercial Parcel #: Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Work Class: Fire Sprinklers Track #: Lot #: Project U: Plan U: Construction Type: Orig. Plan Check U: Plan Check U: Permit No: FPC2018-0069 Status: Closed - Finaled Applied: 03/01/2018 Issued: 03/19/2018 Finaled Close Out: 05/25/2021 Inspector: Final Inspection: Project Title: Description: VIASAT BLDG 12- PRE-ACTION FIRE SPRINKLER SYSTEM FPContractor: SCHMIDT FIRE PROTECTION CO INC-DO NOT USE 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 (858) 279-6122 FEE AMOUNT FIRE Pre-Action System with Alarm $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov IS - - - Fire Protection by Computer Design Schmidt Fire Protection 4760 Murphy Canyon Rd San Diego, CA 92123 (858) 279-6122 Job Name : ViaSat - Level 2 - Preaction System Building BRESSI RANCH BLDG 12 Location : 2501 GATEWAY ROAD System Contract : SFP-916 Data File : Bldg 12 LV2 -Preaction.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Schmidt Fire Protection Page ViaSat - Level 2 - Preaction System Date Hydraulic Design Information Sheet Name - VIASAT Date - 2-20-18 Location - 2501GATEWAY ROAD Building - BRESSI RANCH BLDG 12 System No. - Contractor - Contract No. - SFP-916 Calculated By - Drawing No. - Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - 14-0 Occupancy - ORDINARY HAZARD 2 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 169.36 System Type Sprinkler/Nozzle Density - .20 () Wet Make TYCO D Area Per Sprinkler - 100 ( ) Dry Model TY-FRB B Elevation at Highest Outlet - 13-5 ( ) Deluge Size 1/2" S Hose Allowance - Inside - (X) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - 290.65 Press Required - 61.96 SRC Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 04-05-2017 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 107 @ Press - R Residual Press - 101 Elev. - Well Flow - 3850 Proof Flow S Elevation - U P Location - GATEWAY ROAD AT EL CAMINO REAL P L Source of Information - CITY OF CARLSBAD Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. SR Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non TA Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E £1LiL.L)11LL L)O.L L LL rLL) V LLtLt. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Schmidt Fire Protection Page 2 \aSat - Level 2 - Preaction System Date City Water Supply: Demand: Cl - Static Pressure : 96.3 Dl - Elevation : 15.916 C2 - Residual Pressure: 90.3 D2 - System Flow : 40.65 C2 - Residual Flow : 3850 D2 - System Pressure : 61.964 Hose ( Demand) : 250 D3 - System Demand : 290.65 Safety Margin : 34.285 150 140 130 p120 R° E10° C2 0 90 s 80 u 70 R6° E 50 40 30 20 -- Dl 10 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW( N"1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Schmidt Fire Protection Page 3 ViaSat - Level 2 - Preaction System Date Fitting Legend Ahbrev.Name % % 1 11/4 11/2 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 2024 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 F NFPA I345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow 'Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 H 45 Grvd-Vic Elbow #11 0 0 1 1.5 2 2 3 3 3.5 3.5 4.5 5 6.5 8.5 10 18 20 23 25 30 I 90 rvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90Tëe-BranchGry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 U 45 Eli Firelock #003 0 0 0 0 0 1.8 2.2 2.6 0 3.4 4.2 5 5 0 0 0 0 0 0 0 V 90 Eli Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 Zig Wilkins 375DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure. Units Pounds per Square Inch Note: Fitting 'Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Pressure I Flow Summary - STANDARD Schmidt Fire Protection Page 4 ViaSat - Level 2 - Preaction System Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. D001 0.0 5.6 12.76 na 20.0 0.2 100 7.0 Hi 26.75 K= K@ EQ01 13.54 na 20.0 H2 26.75 K = K @ EQ01 14.43 na 20.65 26.75 14.91 na 2 26.75 24.59 na R2 26.75 27.5 na Ri 26.75 29.18 na P1 25.83 31.01 na MS 25.83 31.02 na M6 25.83 31.11 na M7 25.83 31.18 na TR2 25.83 31.19 na BR2 2.0 44.55 na M 0.5 45.2 na FLG 0.5 45.2 na UG3 -3.0 46.72 na UG4 -3.0 46.73 na FDC -3.0 46.76 na UG5 -3.0 46.76 na 250.0 BF1 -3.0 46.81 na BF2 -3.0 58.86 na SRC -10.0 61.96 na The maximum velocity is 7.67 and it occurs in the pipe between nodes H2 and 1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 5 ViaSat - Level 2 - Preaction System Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 20.00 1.049 1 5.0 1.000 12.755 K Factor 5.60 to 120.0 0.0 5.000 0.0 EQ01 20.0 0.1302 0.0 6.000 0.781 Vel = 7.42 0.0 20.00 13.536 KFactor= 5.44 Hi 20.00 1.049 1 5.0 5.540 13.536 K Factor@ node EQ01 to 120.0 0.0 5.000 0.0 1 20.0 0.1302 0.0 10.540 1.372 Vel = 7.42 0.0 20.00 14.908 KFactor = 5.18 H2 20.65 1.049 0.0 3.460 14.430 K Factor @ node EQOI to 120.0 0.0 0.0 0.0 1 20.65 0.1382 0.0 3.460 0.478 Vel = 7.67 1 20.00 1.61 51 20.0 131.410 14.908 to 120.0 H 2.0 30.000 0.0 2 40.65 0.0600 J 8.0 161.410 9.684 Vel = 6.41 2 0.0 1.61 21 8.0 40.410 24.592 to 120.0 0.0 8.000 0.0 R2 40.65 0.0600 0.0 48.410 2.905 Vel = 6.41 R2 0.0 2.067 V 3.5 6.670 27.497 to 120.0 0.0 3.500 1.500 * * Fixed Loss = 1.5 Ri 40.65 0.0178 0.0 10.170 0.181 Vel = 3.89 Ri 0.0 2.157 7V 30.151 56.750 29.178 to 120.0 T 12.307 42.458 0.398 P1 40.65 0.0144 0.0 99.208 1.433 Vel = 3.57 P1 0.0 4.26 V 8.954 8.290 31.009 to 120.0 0.0 8.954 0.0 M5 40.65 0.0005 0.0 17.244 0.009 Vel = 0.92 M5 0.0 4.26 4V 35.814 142.690 31.018 to 120.0 U 4.477 40.291 0.0 M6 40.65 0.0005 0.0 182.981 0.096 Vel = 0.92 M6 0.0 4.26 3V 26.861 91.420 31.114 to 120.0 0.0 26.861 0.0 M7 40.65 0.0005 0.0 118.281 0.062 Vel = 0.92 M7 0.0 4.26 2V 17.907 14.500 31.176 to 120.0 0.0 17.907 0.0 TR2 40.65 0.0005 0.0 32.407 0.017 Vel = 0.92 TR2 0.0 4.26 V 8.954 8.000 31.193 to 120.0 B 15.8 53.722 13.321 **Fixed Loss 3 BR2 40.65 0.0005 S 28.968 61.722 0.032 Vel = 0.92 Fsp 0.0 BR2 0.0 6.065 2V 20.0 5.000 44.546 to 120.0 L 9.0 29.000 0.650 M 40.65 0.0001 0.0 34.000 0.003 Vel = 0.45 M 0.0 6.357 3V 37.72 5.500 45.199 to 120.0 0.0 37.720 0.0 FLG 40.65 0.0001 0.0 43.220 0.003 Vel = 0.41 FLG 0.0 6.16 L 12.911 8.000 45.202 to 140.0 0.0 12.911 1.516 UG3 40.65 0.0001 0.0 20.911 0.002 Vel = 0.44 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 6 ViaSat - Level 2 - Preaction System Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG3 0.0 5.86 0.0 138.750 46.720 to 150.0 0.0 0.0 0.0 UG4 40.65 0.0001 0.0 138.750 0.010 Vel = 0.48 UG4 0.0 5.86 2L 23.005 316.000 46.730 to 150.0 2F 17.893 40.898 0.0 FDC 40.65 0.0001 0.0 356.898 0.026 Vel = 0.48 FDC 0.0 5.86 1 38.342 6.000 46.756 to 150.0 0.0 38.342 0.0 UG5 40.65 0.0001 0.0 44.342 0.003 Vel = 0.48 UG5 250.00 7.68 2L 28.676 25.000 46.759 Qa = 250 to 140.0 0.0 28.676 0.0 BF1 290.65 0.0009 0.0 53.676 0.046 Vel = 2.01 BF1 0.0 8.27 3L 61.681 10.000 46.805 to 140.0 Zig 0.0 61.681 12.014 **Fixed Loss =12.014 BF2 290.65 0.0006 0.0 71.681 0.042 Vel = 1.74 BF2 0.0 7.68 L 16.29 30.000 58.861 to 150.0 G 5.012 65.159 3.032 SRC 290.65 0.0007 T 43.857 95.159 0.071 Vel = 2.01 0.0 290.65 61.964 KFactor= 36.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2501 Gateway Road CITY: Carlsbad PHONE: ( 858) 279.6122 (Schmidt Fire Protection Company, Inc.) FAX NUMBER: (858 ) 279.3583 Largest Building (ft.2): Sprinkled? Construction Type:, SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Gateway Road at El Camino Real TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 107 PSI (S Hydrant Number (if applicable): H20163 Elevation of test 303 Feet ES ______________________ I M7 all Total Flow: 3,850 GPM Residual Pressure 101 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this exceeds the District's maximum velocity criteria of 15 fps. Therefore, the maximum allowable fire flow for this site is 3,850 gpm. 1Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: _ Title/Org: Ptoie'ct_Manager Date: 04/05/2017 tqccs Fire Protection Products Worldwide www.tyco-fire.com Contacts Preaction System with DV-5 Deluge Valve Single Interlock, Supervised - Electric Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description The TYCO DV-5 Supervised Single In- terlock Preaction System with Elec- tric Actuation (Fig. 1) utilizes automatic sprinklers and a supplemental detec- tion system. The supplemental detec- tion system is typically comprised of 24 VDC heat detectors, smoke detectors, manual pull stations, etc. Actuation of the detection system automatically operates (releases) the DV-5 Deluge Valve, allowing water to flow into the sprinkler piping system and to be dis- charged from any sprinklers that may be open. In accordance with the requirements of the National Fire Protection Asso- ciation, a preaction system employing more than 20 automatic sprinklers is to have the sprinkler piping automati- cally supervised to monitor the overall integrity of the system. In the case of a Supervised Single Interlock Preac- tion System, a Riser Check Valve (that does not require the use of priming wa- ter) provides an air check so that the system can be automatically pressur- ized with a nominal supervisory air or nitrogen pressure of 10 psi (0,69 bar). A supervisory low pressure alarm switch that is set to transfer its contacts at nominally 5 psi (0,34 bar), on decreas- ing pressure, is utilized to indicate whether there are any abnormal leaks in the sprinkler system piping. Loss of air pressure from the system as a re- suit of a damaged sprinkler or broken piping will not cause the DV-5 Valve to open - the air pressure is for supervi- sory alarm only. Typically, the system designer selects the detection components for a single interlock preaction system that will re- spond to a fire sooner than the auto- matic sprinklers. Consequently, the system will experience a minimal de- lay in water delivery over that for a wet pipe sprinkler system because the sys- tem will have begun to fill with water before a sprinkler operates. Supervised single interlock preaction systems are generally used to protect areas where there is danger of serious water damage that might result from damaged automatic sprinklers or pip- ing. Typically, such areas include com- puter rooms, storage areas for valuable artifacts, libraries, and archives. Single interlock preaction systems are also effectively used to protect prop- erties where a pre-alarm of a possible fire condition may allow time for fire ex- tinguishment by alternate suppression means, prior to a sprinkler discharge. In the event the fire cannot otherwise be extinguished, the preaction sprinkler system will then perform as the primary fire protection system. The DV-5 Deluge Valve (described in Technical Data Sheet TFP1305) is a diaphragm style valve that depends upon water pressure in the Diaphragm Chamber to hold the Diaphragm closed against the water supply pressure. When the DV-5 Valve is set for service, the Diaphragm Chamber is pressurized through the trim connections from the inlet side of the system's main control valve, such as an O.S.&Y. gate valve or butterfly valve (Fig. 1). Operation of an electrical detection de- vice such as a heat sensitive thermo- stat, smoke detector, or electrical man- ual control station signals the deluge valve releasing panel to energize the Solenoid Valve. In turn, the energized Solenoid Valve opens to release wa- ter from the Diaphragm Chamber fast- er than it can be replenished through the 1/8 inch (3,2 mm) restriction pro- vided by the Model ASV-1 Automatic Shut- Off Valve in the diaphragm sup- ply connection (Item 5 - Fig. 3A, also described in Technical Data Sheet TFP1384). This results in a rapid pres- sure drop in the Diaphragm Chamber to below the valve trip point. The wa- ter supply pressure then forces the Diaphragm open, permitting water to flow into the system piping, as well as through the Alarm Port to actuate the system alarms. As water flows into the system, the pi- lot chamber of the Model ASV-1 Auto- matic Shut-Off Valve (Item 5 - Fig. 3A) becomes pressurized and the ASV-1 automatically shuts off the diaphragm chamber supply flow to the DV-5 Di- aphragm Chamber. Shutting off the diaphragm chamber supply flow pre- vents the DV-5 Diaphragm Chamber from becoming re-pressurized, there- by preventing inadvertent closing of the DV-5 during a fire (as may be the case should the Solenoid Valve become de- energized after its initial operation). Continued on Page 4 Page 1 of 14 OCTOBER 2014 TFPI420 TFPI42O Page 2 of 14 1 - DV-5 Deluge Valve 2 - Main Control Valve (NO.) 3 - Diaphragm Chamber Supply Control Valve (NO.) 4 - Local Manual Control Station 5 - Automatic Sprinklers 6 - Heat Detectors, Smoke Detectors, etc. (Fire Detection) 7 - Water Supply Pressure Gauge 8 - Diaphragm Chamber Pressure Gauge 9 - System Drain Valve (N.C.) 10 - Main Drain Valve (N.C.) (Shown at Rear of Valve) 11 - Diaphragm Chamber Automatic Shut-Off Valve 12 - Waterflow Pressure Alarm Switch (Shown at Rear of Valve) 13 - Water Motor Alarm (Optional) 14 - Solenoid Valve 15 - Deluge Valve Releasing Panel 16 - Riser Check Valve 17 - Supervisory Air Pressure Gauge 18 - Automatic Supervisory Air/Nitrogen Supply 19 - Supervisory Low Pressure Alarm Switch FIGURE 1(1 0F2) SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION SYSTEM SCHEMATIC (FRONT VIEW) TFPI42O Page 3 of 14 1 - DV-5 Deluge Valve 2 - Main Control Valve (NO.) 3 - Diaphragm Chamber Supply Control Valve (NO.) 4 - Local Manual Control Station (Shown at Front of Valve) 5 - Automatic Sprinklers 6 - Heat Detectors, Smoke Detectors, etc. (Fire Detection) 7 - Water Supply Pressure Gauge (Shown at Front of Valve) 8 - Diaphragm Chamber Pressure Gauge (Shown at Front of Valve) 9 - System Drain Valve (N.C.) 10 - Main Drain Valve (N.C.) 11 - Diaphragm Chamber Automatic Shut-Off Valve (Shown at Front of Valve) 12 - Waterf low Pressure Alarm Switch 13 - Water Motor Alarm (Optional) 14 - Solenoid Valve 15 - Deluge Valve Releasing Panel 16 - Riser Check Valve 17 - Supervisory Air Pressure Gauge (Shown at Front of Valve) 18 - Automatic Supervisory Air/Nitrogen Supply 19 - Supervisory Low Pressure Alarm Switch FIGURE 1(2 0F2) SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION SYSTEM SCHEMATIC (REAR VIEW) TFPI42O Page 4 of 14 LOW AIR PRESSURE WATERFLOW ALARM PRESSURE SWITCH PREACTION ALARM CHECK SINGLE VALVE INTERLOCK SWITCH // \ ELECTRIC ACTUATION IM TR NOTES: SEE FIGURE 3, PER VALVE SIZE AS APPLICABLE, FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS AND COMPONENT PART NUMBERS. TRIM SHOWN FULLY ASSEMBLED; COMPONENTS SUCH AS GAUGES / DV-5 AND SWITCHES MAY REQUIRE DELUGE ASSEMBLY IN TRIM AT VALVE VALVE INSTALLATION. SYSTEM GROOVED SHUT-OFF COUPLING VALVE FIGURE 2 DV-5 PRE-TRIMMED DELUGE VALVE, ELECTRIC ACTUATION The TYCO DV-5 Supervised Single In- terlock Preaction System with Electric Actuation Trim described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of the related devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Approvals UL and C-UL Listed FM Approved Deluge Valve DV-5 Riser Check Valve Model CV-1 FR NOTE: 1-1/2 inch (DN40) risers utilize a 2 inch (DN50) Model CV-1FR Riser Check Valve connected to the 1-1/2 inch (DN40) DV-5 Deluge Valve by a 2 x 1-1/2 inch Figure 716 Reducing Coupling. Valve Trim The Supervised Single Interlock Pre- action System with Electric Actuation Trim (Fig. 3A or 3B) forms a part of the laboratory listings and approvals. The trim is necessary for proper operation of the DV-5 Valve. Each package of trim includes the fol- lowing items: Water Supply Pressure Gauge Diaphragm Chamber Pressure Gauge Diaphragm Chamber Connections Manual Control Station Main Drain Valve System Drain Valve Alarm Test Valve Automatic Drain Valve System Air Pressure Gauge Air Supply Connections Low Air Pressure Supervisory Switch Waterfiow Pressure Alarm Switch (PS1O-2) The following items are included in the Pre-trimmed Valve Assembly and can be ordered separately for the valve trim: Model BFV-N Butterfly Valve Figure 577 Grooved Coupling To ease field assembly of the trim ar- rangement, the trim components are provided partially assembled as shown in Figure 3B. The trim arrangement is provided with galvanized or black nipples and fittings. The galvanized trim is intended for non-corrosive or corrosive conditions, whereas the black trim is principally in- tended for use with AFFF systems. NOTE: When the system pressure is greater than 175 psi (12,1 bar), provi- sion is to be made to replace the stan- dard order 300 psi (20,7 bar) Water Pressure Gauges, shown in Figure 3A or 3B with separately ordered 600 psi (41,4 bar) Water Pressure Gauges. Detection System In order for a single interlock preaction system to be hydraulically calculated as a wet pipe system, as opposed to a dry pipe sprinkler system, the detection system must be designed to operate sooner than the automatic sprinklers on the sprinkler piping. The Supervised Single Interlock Pre- action System with Electric Actuation Trim provides for electric operation of the DV-5 Valve by a detection system consisting of electrical devices such as heat sensitive thermostats, smoke de- tectors, and/or electric manual pull sta- tions. Information on the various types of separately ordered Solenoid Valves that may be used with this trim pack- age is given in Technical Data Sheet TFP2180. Nominal installation dimen- sions for the Supervised Single Inter- lock Preaction System with Electric Ac- tuation Trim are shown in Figure 4. NOTEs: Approval by Factory Mutual is contin- gent on the use of an FM Approved 24VDC Solenoid Valve (P/N 52-287-1- 024 or P/N 52-287-1-124). FM only ap- proves solenoid valves for use in non- hazardous locations. Consult with the authority having ju- risdiction regarding installation cri- teria pertaining to electric actuation circuitry. The Supervised Single Interlock Pre- action System with Electric Actuation Trim is provided with a Model ASV-1 Automatic Shut-Off Valve (Item 5 - Fig. 3A); consequently, the release circuit of the releasing panel need only pro- vide the standard ten minutes of alarm condition intended to energize the So- lenoid Valve. After the ten minute dura- tion, should the Solenoid Valve become de-energized and closed (especially while operating under battery back-up), the Automatic Shut-Off Valve will have already automatically closed thereby preventing the DV-5 Diaphragm Cham- ber from becoming re-pressurized and preventing an inadvertent closing of the DV-5 during a fire event. Continued on Page 10 28 30 20 35 LOCATION FOR OPTIONAL ELECTRICALLY SUPERVISED 33 N.O. ALARM CONTROL VALVE TFPI42O Page 5 of 14 NO. DESCRIPTION OTt'. P/N 1 300 psi/ 2000 kPa Water Pressure Gauge.. 2 92-343-1-005 2 1/4 Gauge Test Valve .................1 46-005-1-002 3 Model MC-1 Manual Control Station ......1 52-289-2-001 4 Model AD-i Automatic Drain Valve .......1 52-793-2-004 5 Model ASV-1 Automatic Shot-Oft Valve ... 1 92-343-1-021 6 Waterfiow Pressure Alarm Switch, Model PSI 0-2 ........................ 1 25710 7 1/2' Ball Valve .......................2 46-050-1-004 8 1/2' Spring Loaded Check Valve.........1 92-322-1-002 9 1/2' V-Strainer .......................1 52-353-1-005 10 3/4' Swing Check Valve................1 46-049-1-005 11 3/4 Angle Valve ...................... 1 46-048-1-005 12 Drip Funnel Connector.................1 92-211-1-005 13 Drip Funnel Bracket ...................1 92-211-1-003 14 Drip Funnel..........................1 92-343-1-007 15 3/32' Vent Fitting .....................1 92-032-1-002 16 1/4'x18'Tubing .....................I CH 17 1/2' Tubing Connector.................1 CH 18 1/2512'Tubing .....................1 CH 19 1/4' Plug............................I CH 20 3/4' Plug............................1 CH 21 1/2' Union. ..........................5 CH 22 3/4' Union, ..........................1 CH 23 1/4' 90' Elbow .......................1 CH NO. DESCRIPTION QTY. P/N 24 1/2' 90' Elbow .......................7 CH 25 3/4' 90' Elbow .......................I CH 26 3/4' 01/2' 90' Elbow..................1 CH 27 1/2 Tee ............................3 CH 28 1/2'xl/4'nl/2' Tee .................. 3 CH 29 3/4' Tee ............................1 CH 30 3/4'v1/2'53/4' Tee..................2 CH 31 l/4's Close Nipple. ...................2 CM 32 1/2' o Close Nipple ...................3 CH 33 1/2'o1-1/2' Nipple ...................11 CH 34 1/2'02 Nipple ......................1 CM 35 1/2'x2-1/2' Nipple ...................3 CH 36 1/2' 05' Nipple ......................2 CH 37 1/2' 07' Nipple ......................1 CH 38 Select Nipple per Table ................I CH 39 Select Nipple per Table ................1 CH 40 3/4'o1-1/2' Nipple ...................6 CH 41 3/4'02' Nipple ......................1 CH 42 3/4 a 4 Nipple I CH P1 250 psi/ 1750 kPa Air Pressure Gauge . .. . 1 92-343-1-012 P2 1/4' Gauge Test Valve .................1 46-005-1-002 P3 Low Air Pressure Alarm Switch, Model PS1D-2 ........................ 1 25710 NO. DESCRIPTION CITY P/N P4 1/4' Pressure Relief Valve ..............1 92-343-1-019 P5 1/2 Swing Check Valve................1 46-049-1-004 P6 1/2' Globe Valve .....................1 46-047-1-004 P7 3/4 Angle Valve ......................1 46-048-1-007 P8 1/4' Plug............................3 CH P9 1/2' v 1/4' Reducing Bucking ...........1 CM P10 1/2' Union, ..........................I CH P11 1/2 90' Elbow .......................1 CH P12 1/2' Cross ..........................1 CH P13 1/2'o1/201/4' Tee..................I CH P14 1'o3/4'xl/2Tea ...................I CH P15 1/4'v3' Nipple ......................1 CH P16 1/2o1-1/2' Nipple ...................5 CH P17 1/2x2-1/2' Nipple ...................1 CH P18 3/4 01-1/2' Nipple ...................1 CH P19 1'02' Nipple........................1 CH El Solenoid Valve Ordered Separately Refer to Per Data Sheet TFP2180 ...............1 Data Sheet E2 1/2' Tubing Connector.................1 CH 03 1/2'v24'Tubing .....................1 CH 04 1/2"v1-1/2' Nipple ...................1 CM COMPONENTS INCLUDED ONLY IN PRE-TRIMMED VALVE ASSEMBLIES: Al Model CV-1 FR Check Valve, 2' (DNSO) ... 1 59-590-1-020 A2 Butterfly Valve, Power Bull 300: 1-1/2'(DN40) ........................1 51024A 2' IDN50) ...........................1 51021A A3 Figure 577 Coupling: 1-1/2' (DN40) ........................1 57715ACP 2' (DN50) ...........................1 57720ACP A4 Coupling for 1-1/2' (DM40) DV-5: Figure 716 Reducing Coupling, 2' 5 1-1/2!. I 7182015E5 Coupling for 2' (DN50) DV-5: Figure 577 Coupling, 2' ................I 57720ACP P P5 4 P11 P3 P16 P13 6 P16 P16 P16' P15 Pi P6 15 P12 26 (GREEN ''__ 40 P14 /33 TINT) 16 P8 27 El (ORDERED v PLUG 12 E3 40 29 SEPARATELY) UNUSED 14 E2 E4 22 PORTS 13 36 21 32 21 33 10 40 0 P8 Al 24 27- 40 40 35 24 24 30 P8'- A4 27 B 25 33 32 24 ii 42 28 37 33 NOTES: 35 A3 9 8 Supervised Single Interlock 1 33 3 Actuation is comprised of 2 21 36 24 5 21 Preaction Trim with Electric 34 32 Items 1-42 plus Items P1-P19 33 - 18 and Items E2-E4. Item El 33 31 28 33 17 ordered separaetly. Items 2" (DN5O) 24 24 A1-A4 included only in 23 31 GROOVE x GROOVE 21 pre-trimmed valve assemblies DV-5 DELUGE VALVE as applicable; otherwise SHOWN NOTES: ordered separately. 33 4. See Figure 2 of TFPI 305 for All Fittings and Nipples are Deluge Valve Port identification. galvanized (Standard Order). 7 5. Route all Tubing to Drip Funnel, CH: Common Hardware. Item 14. FIGURE 3A (1 OF 3) 1-1/2 AND 2 INCH (DN40 AND DN50) DV-5 SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION TRIM EXPLODED VIEW Nipple Number I Select Appropriate Nipple Sizes I per DV-5 Deluge Valve Size 1-1/2' IDN40I I 2' (DNSO) 38 1/2'oClose 1 l/2'02' 39 1/2'05' I 1/2'05-1/2' TFPI42O Page 6 of 14 NO. DESCRIP11ON QTY P/N 1 300 psi/ 2000 kPa Water Pressure Gauge.. 2 92-343-1-005 2 1/4' Gauge Test Valve .................1 46-005-1-002 3 Model MC-11 Manual Control Station ......1 52-289-2-001 4 Model AD-11 Automatic Drain Valve .......1 52-793-2-004 5 Model ASV-i Automatic Shut-DO Valve ... 1 92-343-1-021 6 Waterflow Pressure Alarm Switch, Model PSiO-2 ........................ 1 25710 7 1/2" Ball Valve .......................2 46-050-1-004 8 1/2" Spring Loaded Check Valve .........1 92-322-1-002 9 1/2" V-Strainer .......................I 52-353-1-005 10 3/4 Swing Check Valve................1 46-049-1-005 11 1-1/4 Angle Valve ....................1 46-048-1-007 12 Drip Funnel Connector.................1 92-211-1-005 13 Drip Funnel Bracket ...................1 92-211-1-003 14 Drip Funnel..........................1 92-343-1-007 15 3/32" Vent Fitting .....................1 92-032-1-002 16 1/4" 0 18' Tubing .....................1 CH 17 1/2' Tubing Connector.................1 CH 28 30 20 L NO. DESCRIPTION OTY. P/N 18 1/2's 18" Tubing .....................1 CH 19 1/4' Plug............................I CH 20 3/4" Plug............................1 CH 21 1/2" Union ........................... 5 CH 22 3/4" Union ........................... 1 CH 23 1/4" 90" Elbow .......................1 CH 24 1/2" 90" Elbow .......................7 CH 25 3/4"s1/2 90" Elbow .................. 1 CH 26 1-1/4" 90" Elbow .....................1 CH 27 1/2" Tee ............................3 CH 28 1/2" o 1/4 e 1/2 Tee..................3 CH 29 3/4" Tee ............................1 CH 30 3/4"v1/2' v3/4" Tee..................2 CH 31 1/4" o Close Nipple ...................2 CH 32 1/2"x Close Nipple. ...................2 CH 33 1/20s1-1/2" Nipple ...................13 CH 34 1/2" x2-1/2" Nipple ...................1 CH 35 1/2"e3-1/2" Nipple ...................1 CH 33 4 14 13 NO. DESCRIPTION OTY. P/N 36 1/2" s4" Nipple ......................1 CH 37 1/2" 04-1/2" Nipple ...................1 CH 38 1/2" 05" Nipple ......................1 CH 39 1/2"05-i/2" Nipple ...................1 CH 40 1/2"e7" Nipple ......................2 CH 41 3/4"x1-1/2" Nipple ...................5 CH 42 3/4"x2" Nipple ......................1 CH 43 1-1/4" 02 Nipple ..................... 1 CH 44 1-1/4" 04 Nipple ..................... 1 CH P1 250 psi/ 1750 kPa Air Pressure Gauge .... 1 92-343-1-012 P2 1/4" Gauge Test Valve .................1 46-005-1-002 P3 Low Air Pressure Alarm Switch, Model P510-2 ........................ 1 25710 P4 1/4" Pressure Relief Valve ..............1 92-343-1-019 P5 1/2 Swing Check Valve ................ 1 46-049-1-004 P6 1/2" Globe Valve .....................1 46-047-1-004 P7 1-1/4 Angle Valve ....................1 46-048-1-007 P8 1/4" Plug............................3 CH P9 1/2" v 1/4" Reducing Bushing ...........1 CH P10 1/2" Union. ..........................1 CH P11 1/2" 90" Elbow .......................1 CH P12 1/2" Cross. ..........................I CH P13 1/2"o1/2"x1/4" Tee..................I CH P14 1-1/4"o1-1/4"x1/2" Tee ............... 1 CH P15 1/4"o3" Nipple ......................1 CH P16 1/2"xl-1/2" Nipple ...................6 CH P17 1-1/4" 02" Nipple ..................... 1 CH P18 1-1/4" 03" Nipple ..................... 1 CH El Solenoid Valve Ordered Separately Refer to Per Data Sheet TFP2180 ...............1 Data Sheet 82 1/2" Tubing Connector ................. 1 CH E3 1/2" o24 Tubing .....................1 CH E4 1/201-1/2 Nipple ...................1 CH COMPONENTS INCLUDED ONLY IN PRE-TRIMMED VALVE ASSEMBLIES: Al Model CV-1 FR Check Valve, 3" (DN80) ... 1 59-590-1-030 A2 Model BFV-N Butterfly Valve, 3" (DNEO) ... 1 59300F030N A3 Figure 577 Coupling, 3" (DN80) ..........2 57730ACP El (ORDERED E3 SEPARATELY) P16 P4 P16 P13 P16 P6 P1 25 P11 P10 P3 41 6 P16 P9 1) P16 P15 15 P12 - 27 (GREEN TINT) 16 P16 P8 12'I VP7P17 - n.e 34 rrjnlo -- E4 E2'""- 29 42 41 22 PB Al 39 21 33 21 LOCATION 41 33FOR 36 OPTIONAL 41 P8 ELECTRICALLY 27 SUPERVISED 33 10 0 24 40 N.O. ALARM 24 41 24 24 CONTROL 30 A3 27 VALVE 33 33 33 26 28 7 43 44 40 11 ' 5 33 3 38 8 NOTES: 21 21 1. Supervised Single Interlock 19 2 A3 24 32 Preaction Trim with Electric - 35 18 Actuation is comprised of 37 A2 9 17 Items 1-44 plus Items P1-P18 33 33 24 24 and Items E2-E4. Item El 31 28 33 3 ordered separaetly. Items 31 A1-A3 included Only in 23 3 (DN8O) 21 pre-trimmed valve assemblies as applicable; otherwise GROOVE it GROOVE NOTES: ordered separately. DV-5 DELUGE VALVE 33 4. See Figure 2 of TFP1305 for 2. All Fittings and Nipples are SHOWN Deluge Valve Port identification. galvanized (Standard Order). 7 5. Route all Tubing to Drip Funnel, 3. CH: Common Hardware. Item 14. FIGURE 3A (2 OF 3) 3 INCH (DNBO) DV-5 SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION TRIM EXPLODED VIEW 43 1 47 rw -.- 28 40 21 TFPI42O Page 7 of 14 NO. DESCRIPTION OTY. P/N 1 300 psi, 2000 kPa Water Pressure Gauge.. 2 92-343-1-005 2 1/4" Gauge Test Valve .................I 46-005-1-002 3 Model MC-I Manual Control Station ......1 52-289-2-001 4 Model AD-1 Automatic Drain Valve .......1 52-793-2-004 5 Model ASV-1 Automatic Shut-Ott Valve ... 1 92-343-1-021 6 Watertlow Pressure Alarm Switch, Model PSI O-2 ........................ 1 25710 7 1/2" Ball Valve .......................2 46-050-1-004 8 1/2" Spring Loaded Check Valve .........1 92-322-1-002 9 1/2" V-Strainer .......................1 52-353-1-005 10 3/4" Swing Check Valve................1 46-049-1-005 ii Item No. Not Used 12 2 Angle Valve .......................1 46-048-1-009 13 Drip Funnel Connector.................1 92-211-1-005 14 Drip Funnel Bracket ...................1 92-211-1-003 15 Drip Funnel..........................1 92-343-1-007 16 3/32 Vent Fitting .....................1 92-032-1-002 17 114"x24" Tubing .....................I CH 18 1/2" Tubing Connector.................I CH 19 1/2"x24" Tubing .....................I CH 20 1/4" Plug ............................ 1 CH 21 3/4" Plug ............................ t CH 22 1/2" Union ........................... 5 CH 23 1" Union ............................1 CH 24 1/4" 90" Elbow .......................1 CH 25 1/2" 90" Elbow .......................7 CH 26 1/2" Tee ............................3 CH 27 28 P14 21 LOCATION FOR OPTIONAL ELECTRICALLY SUPERVISED N.O. ALARM CONTROL VALVE NO. DESCRIPTION 01?. P/N 27 112"xl/4"vl/2" Tee .................. 3 CH 28 3/401/2" a 3/4" Tee..................2 CH 29 1"v1/2" 90" Elbow .................... 1 CH 301"x3/4"ot"Tee .....................1 CH 31 2" 90" Elbow ......................... 1 CH 32 1/4" a Close Nipple .................... 2 CH 33 1/2 a Close Nipple. ...................2 CH 34 1/2"e1-1/2" Nipple ...................10 CH 35 1/2 02-1/2' Nipple ...................2 CH 36 1/2"x3" Nipple ......................I CH 37 1/2" 55" Nipple ......................2 CH 38 1/2"s6" Nipple ......................I CH 39 1/2 x7' Nipple ......................2 CH 40 Select Nipple per Table ................1 CH 41 Select Nipple per Table ................1 CH 42 Select Nipple per Table ................I CH 433/4 a 1-1/2' Nipple ...................I CH 443/4"o2"Nipple ......................I CH 45 Select Nipple per Table ................I CH 46 1" a Close Nipple .....................2 CH 47 1' o3"Nipple ........................1 CH 48 Item No. Not Used 492" a3" Nipple ........................2 CH P1 250 psi, 1750 kips, Air Pressure Gauge .. . . 1 92-343-1-012 P2 1/4" Gauge Test Valve .................1 46-005-1-002 P3 Low Air Pressure Alarm Switch, Model PS1O-2 ........................ 1 25710 P6 T.0_~',P4 29 36 15 14 Al NO. DESCRIPTION OTY PIN P4 1/4" Pressure Relief Valve ..............1 92-343-1-019 P5 1/2" Swing Check Valve................1 46-049-1-004 P6 1/2" Globe Valve .....................1 46-047-1-004 P7 2 Angle Valve .......................1 46-048-1-009 P8 1/4" Plug............................3 CH P9 1/2" a 1/4" Reducing Bashing ...........1 CH PlO 1/2" Union ..........................1 CH Pit l/2"90"Elbow .......................1 CH P12 1/2 Cross ........................... 1 CH P13 1/2 ei/2"x114" Tee .................. 1 CH Pt42"o2"xi/2"Tee .....................1 CH P15 1/4"a3" Nipple ......................1 CH P16 1/2 a 1-1/2" Nipple ...................6 CH P172"x3"Nipple ........................2 CH El Solenoid Valve Ordered Separately Rater to Per Data Sheet TFP2180 ...............1 Data Sheet E2 1/2 Tubing Connector ................. 1 CH E3 1/2"a24" Tubing .....................1 CH E4 1/2a1-1/2" Nipple ...................1 CH COMPONENTS INCLUDED ONLY IN PRE-TRIMMED VALVE ASSEMBLIES: Al Model CV-1 FR Check Valve: 4' IDN100l ..........................1 59-590-1-040 6" lDN1 50I ..........................1 59-590-1-060 8" ION200I ..........................1 59-590-1-080 A2 Model BFV-N Butterfly Valve: 4" (DNlOOI ..........................1 59300F040N 6"(DN150) ..........................1 59300F060N 8" (DN200) ..........................1 59300F080N A3 Figure 577 Coupling: 4" lDN100I ..........................2 57740ACP 6" IDNi50I ..........................2 57760ACP 8" (DN200) ..........................2 57780ACP Nipple No. Select Appropriate Nipple Sizes per DV-5 Deluge Valve Size 4" (ON 100) 6" (DNI50) 8" (ON200) 40 1/2"a2-1/2" I/2"05-112" l/208-i/2" 41 l/2"v2"2".3 -1/2" 42 i/2"06-112" l/2"57-l/2" 112e9" 45 3/4" 02-1/2" 3/4" a 3-1/2" 3/4" x4-1/2" 27 P16 Lj :h1 0 16 16 P16' (GREEN P12 TINT) 17 /1 P16 P1 46 P9 P15 P8 I P2 13 UNUSED PLUG P17 PORTS P8 30 23 P8' El - (ORDERED E3 -.--' SEPARATELY) E4 38 22 41 22 - 25 26 34 Ix— 35 25 A3 34 NOTES: 39 9 Supervised Single Interlock :2 33 Preaction Trim with Electric A3 25 19 37 '4 Actuation is comprised of Items 1-49 plus Items P1-Ph 34 18 and Items E2-E4. Item El A2 3 34 ordered separaetly. Items 32 2 A1-A3 included only in 25 25 pre-trimmed valve assemblies 24 32 - 22 NOTES: as applicable; otherwise ordered separately. DV-5 DELUGE VALVE l.rJ Deluge Valve Port identification, All Fittings and Nipples are GROOVE x GROOVE ".4( 4. See Figure 2 of TFP13O5 for galvanized (Standard Order), SHOWN 7 5. Route all Tubing to Drip Funnel, CH: Common Hardware. Item 15. FIGURE 3A (3 OF 3) 4, 6, AND 8 INCH (DN100, DNI50 AND DN200) DV-5 SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION TRIM EXPLODED VIEW WATERFLOW PRESSURE ALARM SWITCH / CONTROL VALVE (NORMALLY OPEN) DRIP 3/4 INCH NPT FUNNEL CONNECTION FOR DRAIN _UTOMATIC WITH 1-1/4 WATER MOTOR B VALVE INCH NPT ALARM i'NIPPLE CONNECTION \ TO DRAIN LOCATION FOR OPTIONAL ELECTRICALLY SUPERVISED N.O. ALARM CONTROL VALVE NIPPLE MAIN DRAIN VALVE (NORMALLY CLOSED) SYSTEM MAIN DRAIN CONNECTION (SIZED PER TABLE) N, SYSTEM MAIN DRAIN VALVE (NORMALLY \ CLOSED) -. E PLUG F UNUSED PORTS ALARM TEST VALVE A (NORMALLY CLOSED) TFPI 420 Page 8 of 14 NOTES: Use only 2' (DN50) Model CV-1 FR Riser Check Valve in 1-1/2 (DN40) and 2' (DN50) assemblies. Use CV-1 FR Valve size equal to mating DV-5 Valve in larger assemblies. Nipples 1-4 vary in length relative to DV-5 size. Select per table. All other nipples packed unassembled shall be installed per appropriate trim exploded view, Figure 3A Part 1, 2, 0r3. Install subassemblies in alphabetical order. See Figure 2 of TFP1305 for Deluge Valve Port identification. Route all Tubing to Drip Funnel. VENT FITTING SYSTEM (GREEN TINT) AIR SUPPLY Nipple Number Select Appropriate Nipple Sizes per DV-5 Deluge Valve Size 1-1/2 (DN40) 2' (DN50) 3" (DN80) 4" (DN100) 6' (DN150) 8' (0N200) 1 1/2'xClose 1/2'x2' 1/2"x1-1/2' 1/2"x2-1/2' 1/2"x5-1/2' 1/2'x8-1/2" 2 1/2"xClose 1/2'xClose 1/2'x1-1/2 1/2°x2" 1/2"x3" 1/2x3-1/2" 3 1/2 x5' 1/2"x5-1/2 1/2"x7" 1/2' x6-1/2" 1/2" x7-1/2" 1/2 x9" 4 3/4"x1-1/2" 3/4'x1-1/2' 3/4'x1-1/2" 3/4'x2-1/2' 3/4x3-1/2' 3/4'x4-1/2' System Main Drain 3/4" NPT 3/4" NPT Size 1-1/4" NPT 2' NPT 2" NPT 2" NPT Main Drain Size 3/4' NPT 3/4' NPT 1-1/4 NPT 2" NPT 2" NPT 2 NPT LOW AIR PRESSURE ALARM SWITCH 1/2 INCH NPT CONNECTION FOR SYSTEM fr AIR SUPPLY SOLENOID VALVE, ORDERED SEPARATELY 1/2 INCH SYSTEM (NORMALLY CLOSED) CONDUIT AIR SUPPLY ! — GAUGE CONNECTION PRESSURE FOR "ELECTRIC DETECTION" RISER CHECK VALVE NIPPLE (NOTE 1) NIPPLE AUTOMATIC 3 SHUT-OFF VALVE (NORMALLY DIAPHRAGM OPEN) CHAMBER PRESSURE GAUGE 0 MANUAL D CONTROL 0 STATION SYSTEM DIAPHRAGM WATER 4" (DN100) CHAMBER SUPPLY I SUPPLY FLANGE x GROOVE CONTROL VALVE PRESSURE DV-5 DELUGE (NORMALLY GAUGE VALVE SHOWN 1/2 INCH NPT OPEN) CONNECTION CONNECTION FROM (SIZED PER TABLE) WATER SUPPLY FIGURE 3B 1-1/2 THRU 8 INCH (DN40 THRU DN200) DV-5 SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM OPERATIONAL COMPONENTS SEMI-PREASSEMBLED TRIM EXPLODED ARRANGEMENT TFPI 420 Page 9 of 14 Valve Nominal Installation Dimensions in Inches and (mm) Size A B C D E F G H J K L M N 1-1/2 7.00 8.88 13.00 10.50 20.50 4.00 5.81 5.81 3.00 7.00 4.00 14.81 4.02 (DN40) (177,8) (225,4) (330,2) (266,7) (520,7) (101,6) (147,6) (147,6) (76,2) (177,8) (101,6) (376,2) (102,1) 2' 7.13 9.13 13.00 10.50 21.06 3.13 6.00 6.00 3.00 7.00 3.13 15.38 4.09 (DN50) (181,0) (231,8) (330,2) (266,7) (535,0) (79,4) (152,4) (152,4) (76,2) (177,8) (79,4) (390,5) (103,9) 7.81 10.44 14.50 10.50 25.00 1.69 6.69 6.69 4.25 7.00 0.25 21.13 3.85 (DN80) (198,4) (265,1) (368,3) (266,7) (635,0) (42,9) (170,0) (170,0) (108,0) (177,8) (6,4) (536,6) (98,0) 10.00 11.75 17.88 10.50 29.13 1.75 6.50 8.56 6.25 7.13 0.38 25.38 4.56 (DN100) (254,0) (298,5) (454,0) (266,7) (739,8) (44,5) (165,1) (217,5) (158,8) (181,0) (9,5) (644,5) (116,0) 6" 11.38 14.31 18.75 10.50 31.94 3.50 7.88 9.94 6.25 7.13 1.56 29.63 5.86 (DN150) (289,0) (363,5) (476,3) (266,7) (811,2) (88,9) (200,0) (252,4) (158,8) (181,0) (39,7) (752,5) (149,0) 8" 12.00 16.00 21.25 10.50 36.75 1.75 10.75 10.63 6.25 7.13 7.13 36.50 5.26 (DN200) (304,8) (406,4) (539,8) (266,7) (933,5) 1 (44,5) 1 (273,1) 1 (269,9) 1 (158,8) (181,0) (181,0) (927,1) (134,0) * MINIMUM CLEARANCE. H LEFT VIEW FRONT VIEW FIGURE 4 1-1/2 THRU 8 INCH (DN40 THRU DN200) DV-5 SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM NOMINAL INSTALLATION DIMENSIONS TFPI42O Page 10 of 14 System Air Pressure Requirements The supervisory air (nitrogen) pressure is to be 10 ± 2 psi (0,69 plus or minus 0,07 bar). The use of a higher supervi- sory pressure is subject to approval by the authority having jurisdiction, and it should be understood that the use of a higher supervisory pressure may in- crease water delivery time. The use of a lower supervisory pressure may pre- vent clearing the alarm of the Supervi- sory Low Pressure Alarm Switch (Item P3 - Fig. 3A), which is factory set to alarm at 5 ± 1 psi (0,34 ± 0,07 bar) on decreasing pressure. The supervisory air supply pressure of 10 ± 2 psi (0,69 ± 0,07 bar) can be provided by any of the following methods. Refer to the ap- plicable data sheet for laboratory ap- proval information. Model G16AC812 (self contained) Automatic Supervisory Air Supply described in Technical Data Sheet TFP162O. A maximum 200 psi (13,8 bar) plant air supply in combination with the Model AMD-1 Air Maintenance De- vice described in Technical Data Sheet TFP1221. A maximum 3000 psi (206,9 bar) ni- trogen cylinder in combination with the Model AMD-3 Nitrogen Mainte- nance Device described in Technical Data Sheet TFP1241. NOTE: The dew point of the air or ni- trogen supply for a system exposed to freezing conditions must be maintained below the lowest ambient temperature to which the system piping will be ex- posed. Introduction of moisture into the system piping can create ice build- up that could prevent proper operation of the system. The Supervisory Low Pressure Alarm Switch (Item P3 - Fig. 3A) is factory set at 5 ± 1 psi (0,34 ± 0,07 bar) on de- creasing pressure. The Pressure Relief Valve (Item P4- Fig. 3A) is factory set to fully open at 25 ± 2 psi (1,72 ± 0,14 bar) and it begins to crack open at a pres- sure of about 18 psi (1,24 bar). Friction Loss The nominal pressure loss versus flow data for the DV-5 Deluge Valve plus Riser Check Valve is provided in Graph A. Installation General Instructions Proper operation of the DV-5 Deluge Valve depends upon its trim being in- stalled in accordance with the instruc- tions given in this technical data sheet. Failure to follow the appropriate trim diagram may prevent the DV-5 Valve from functioning properly, as well as void listings, approvals, and the manu- facturer's warranties. 1-1/2 inch (DN40) risers utilize a 2 inch (DNSO) Riser Check Valve in combina- tion with the 1-1/2 inch (DN40) DV-5 Deluge Valve. The DV-5 Valve must be installed in a readily visible and accessible location. The DV-5 Valve associated trim must be maintained at a minimum tempera- ture of 40°F (4°C). Heat tracing of the DV-5 Valve or its associated trim is not permitted. Heat tracing can result in the formation of hardened mineral deposits that are ca- pable of preventing proper operation. The DV-5 Deluge Valve is to be in- stalled in accordance with the follow- ing criteria: Step 1. All nipples, fittings, and de- vices must be clean and free of scale and burrs before installation. Use pipe thread sealant sparingly on male pipe threads only. Step 2. The DV-5 Valve must be trimmed in accordance with Figure 3A or 3B. Step 3. Care must be taken to ensure that check valves, strainers, globe valves, etc. are installed with the flow arrows in the proper direction. Step 4. Drain tubing to the Drip Funnel must be installed with smooth bends that will not restrict flow. Step 5. The main drain and Drip Funnel drain may be interconnected provided a check valve is located at least 12 inches (300 mm) below the Drip Funnel. Step 6. Suitable provision must be made for disposal of drain water. Drain- age water must be directed such that it will not cause accidental damage to property or danger to persons. Step 7. Connect the Diaphragm Cham- ber Supply Control Valve to the inlet side of the system's Main Control Valve in order to facilitate setting of the DV-5 Valve (Ref. Figure 4). Step 8. Unused pressure alarm switch connections must be plugged. Step 9. A suitable automatic supervi- sory air (nitrogen) supply, as described in the Technical Data section, is to be installed in accordance with the appli- cable technical data sheet and set for 10 ± 2 psi (0,69 ± 0,14 bar). Step 10. A desiccant dryer, when re- quired for the supervisory air supply, is to be installed between a drip leg and the Model AMID-1 Air Maintenance De- vice or between the Model G16AC812 Automatic Supervisory Air Supply and the Preaction Trim. Step 11. The Supervisory Low Pres- sure Alarm Switch is to be wired to the supervisory alarm initiating circuit of an alarm panel. Step 12. Conduit and electrical con- nections are to be made in accordance with the requirements of the authority having jurisdiction and/or the National Electric Code. Step 13. Before a system hydrostatic test is performed in accordance with NFPA 13 system acceptance test re- quirements, the DV-5 Diaphragm Chamber is to be depressurized; the Automatic Drain Valve (Item 4, Fig. 3A) is to be temporarily replaced with a 1/2 inch NPT plug, the 3/32 inch Vent Fit- ting (16 - Fig. 3A) is to be temporarily replaced with a 1/4 inch NPT plug, and the Diaphragm Cover Bolts must be uniformly and securely tightened using a cross-draw sequence. After tighten- ing, double-check to make certain that all of the Diaphragm Cover Bolts are securely tightened. Valve Setting Procedure Steps 1 through 12 are to be performed when initially setting the DV-5 Deluge Valve after an operational test of the fire protection system, or, after system operation due to a fire. Step 1. Close the Main Control Valve. Step 2. Close the Diaphragm Cham- ber Supply Control Valve, the Dry Pilot Line Air Supply Control Valve, and the Supervisory Air Supply Control Valve. Step 3. Open the Main Drain Valve, System Drain Valve, and all auxiliary drains in the system. Close the System Drain Valve and auxiliary drain valves after water ceases to discharge. Leave the Main Drain Valve open. Step 4. Depress the plunger of the Au- tomatic Drain Valve to verify that it is open and that the DV-5 Valve is com- pletely drained. Continued on Page 12 TFPI42O Page 11 of 14 I . I,III .....i.ilu......II •I...III....... Id.......IIII moons I •uIIIu•••luuI••uu••uuIrA••vAU••IuuunHhuIfluPju•uuuIV4••uuuuuur1••I,, uiiii••••uuuuu••••uuui••r•iuuuuuiuuuuiuiuiiuuuuuviuu••uuuuu•v••i IIIII•U•IIIII•UUUUIIlAI•WlUUIIIIIIIIIIIIIII4UlIIUIUU••••IIII•1••• uiiiiuuuuuuuuuuuuuuwuu•ri•uuuiiuiuuiuiiiui•uiuupiu•uuuuuuuia•uu ' II I , v. uuuuu•••uuu•u rA•••••••u••uu•uuuurluu•••••auu ••uuuur •• ••U••••UUUiiI4uui••••V1UU••U•Ui•U I .1 I iuiui•••UU•I•JUU• uuuuuu•••uuuuiu••uu••iuuuiiuriuuuuuu•uiuuuu•uu••••uu••u••i' I I .....____..._ U•UUI •WA 22 41ANIM101 •••U ••••AUUUUU•UU •••••'MA WE .1 .. M ME ME ••.•4 A • — - ......O, 4••U ,____._____ .wu....nn.i ....a... .......w IuI•I••••VA logo•...I.....w 4•••U A...... wu ' • MOMS ••u1u1urZZ •••........ra M.M. MWAMMM - • uuu11.......1.i....... iiui••••uuu••uu•uuu• 00 • 1 ~~MWWWMMMMM iuiui•ui•ua•uu••uuu 1•uuI!luuuI•uu••Iu•V4•U•••l•••• ., - ' 11111••••rA••IW••••••••i• 1ui11••uruuuiri•uuuu•uuu• u.u.u.u...,........iMrA A6 11111 UUU1UliIII••U•••I•••••••U••••• MEAN u. 0 111111E - • OFAMENNOOKINEEN III iuinuruuu!ii•uuiuuuui•uriuuumnumuuPiu•uiruuuu••uu • ME MEMO NNEENEMEW'AMMMEME ""I'm MOMMMMMI milli on mommommoomm - • 'S : - _uuIuIUIIuuuii•UUUiIiIiUUUUUiiIiiiiiiiiiiIIiIiliF1I•iiiiiii•U•Ul • milli IS 1011 mommwmmmmmmm ollplimillommo MIMMIM00 IN, s; • flhuIIII•U••uuIEUUUPdU•I••••UUBI!iIIuI,III••Uluui•UU•••UUii•UUUU I. 10111111111 RUNS on %mom-;; IS IS no MMMMOMMEMENOMEN' 01"ME 0000 ommummommm 11101111 MEMS MOMM 0111MFA .0010.00 imommoli NONE MMMMOMEMEEMMMMM III' A51I ,, IISIS Q51115'IhIuII e approximate triction loss, based on the Mazen and'Hilliams formula and expressed in equivalent length ot pipe With C-120, is as follows: 15 feet of 1-1/2 Sch. 40 pipe for the 1-1/2 inch Valve Combination— calculated on a typical flow rate of 100 gpm. 28 feet of 2 inch Sch. 40 pipe for the 2 inch Valve Combination* calculated on a typical flow rate of 175 gpm. 37 feet of 3 inch Sch. 40 pipe for the 3 inch Valve Combination* calculated on a typical flow rate of 350 gpm. 48 feet of 4 inch Sch. 40 pipe for the 4 inch Valve Combination* calculated on a typical flow rate of 600 gpm. 73 feet of 6 inch Sch. 40 pipe for the 6 inch Valve Combination* calculated on a typical flow rate of 1500 gpm. 103 feet of 8 inch Sch. 30 Pipe for the 8 inch Valve Combination* calculated on a typical flow rate of 2500 gpm. GRAPH A DELUGE AND CHECK VALVE COMBINATION* NOMINAL PRESSURE LOSS VERSUS FLOW *DV-5 Deluge Valve combined with Model CV-1FR Riser Check Valve **1-112 Inch DV-5 Deluge Valve combined with 2 Inch Model CV-1FR Riser Check Valve TFPI 420 Page 12 of 14 Step 5. Clean the Strainer in the Dia- phragm Chamber Supply connection by removing the clean-out plug and strainer basket. The Strainer may be flushed out by momentarily opening the Diaphragm Chamber Supply Con- trol Valve. Step 6. Reset the actuation system. Manual Actuation - Push the operat- ing lever up; however, do not close the hinged cover at this time. Electric Actuation - Reset the electric detection system in accordance with the manufacturer's instructions to de- energize the Solenoid Valve. Step 7. Open the Diaphragm Chamber Supply Control Valve and allow time for full pressure to build up in the Dia- phragm Chamber. Step 8. Operate (open) the Manu- al Control Station to vent trapped air from the Diaphragm Chamber. If nec- essary, first open the hinged cover, and then fully pull down on the operating lever. Slowly close the operating lever by pushing it up after aerated water ceases to discharge from the Manual Control Station drain tubing. Close the hinged cover and insert a new break rod in the small hole through the top of the enclosing box. Step 9. Inspect the drain connections from the Manual Control Station and Solenoid Valve. Any leaks must be cor- rected before proceeding to the next step. Step 10. Verify the ability for the DV-5 Diaphragm to hold pressure as follows: With the diaphragm chamber pres- surized per Step 8, temporarily close the Diaphragm Chamber Sup- ply Control Valve, and then monitor the Diaphragm Chamber Pressure Gauge for a drop in pressure. If a drop in pressure is noted, the DV-5 Diaphragm is to be replaced and/or any leaks must be corrected before proceeding to the next step. If the Diaphragm Chamber Pressure Gauge does not indicate a drop in pressure, re-open the Diaphragm Chamber Supply Control Valve and proceed to the next step. Step 11. Replace operated automatic sprinklers on the system piping and then open the Supervisory Air Supply Control Valve and allow the system to automatically re-establish its nominal air pressure of 10 psi (0,69 bar). Ob- serve the Automatic Drain Valve for leaks. If there are leaks, determine/cor- rect the cause of the leakage problem within the Riser Check Valve. NOTE: In order to prevent the pos- sibility of a subsequent operation of an over-heated solder type automat- ic sprinkler, any solder type automat- ic sprinklers that were possibly ex- posed to a temperature greater than their maximum rated ambient must be replaced. Step 12. Slowly open the Main Con- trol Valve. Close the Main Drain Valve as soon as water discharges from the drain connection. Observe the Auto- matic Drain Valve for leaks. If there are leaks, determine/correct the cause of the leakage problem. If there are no leaks, the DV-5 Valve is ready to be placed in service and the Main Control Valve must then be fully opened. NOTES: When the Main Control Valve is opened, the pressure on the Dia- phragm Chamber may increase. This increase in pressure is normal. If the pressure is greater than 250 psi (17,2 bar), the pressure is to be relieved by partially and temporarily opening the Manual Control Station; however, do not allow the pressure as indicated on the Diaphragm Chamber Pressure Gauge to drop below the supply pres- sure shown on the Water Supply Pres- sure Gauge since this action may result in tripping of the DV-5 Valve. After setting a fire protection system, notify the proper authorities and advise those responsible for monitoring pro- prietary and/or central station alarms. Care and Maintenance The following procedures and inspec- tions must be performed in accor- dance with this section, in addition to any specific requirements of the NFPA, and any impairment must be immedi- ately corrected. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must first be obtained from the proper au- thorities and all personnel who may be affected by this action must be notified. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. NOTICE Some of the procedures outlined in this section will result in operation of the associated alarms. Consequently, notification must first be given to the owner and the fire department, central station, or other signal station to which the alarms are connected. Annual Operation Test Procedure Proper operation of the DV-5 Valve (i.e., opening of the DV-5 Valve as during a fire condition) must be verified at least once a year as follows: Step 1. If water must be prevented from flowing beyond the riser, perform the following steps. Close the Main Control Valve. Open the Main Drain Valve. Open the Main Control Valve one turn beyond the position at which water just begins to flow from the Main Drain Valve. Close the Main Drain Valve. Step 2. Test the Deluge Valve Releas- ing Panel in accordance with the man- ufacturer's instructions to energize the Solenoid Valve. NOTE: Be prepared to quickly perform Steps 3, 4, and 5 if water must be pre- vented from flowing beyond the riser. Step 3. Verify that the DV-5 Valve has tripped, as indicated by the flow of wa- ter into the system. Step 4. Close the system's Main Con- trol Valve. Step 5. Close the Diaphragm Cham- ber Supply Control Valve, the Dry Pilot Line Air Supply Control Valve, and the Supervisory Air Supply Control Valve. Step 6. Reset the DV-5 Deluge Valve in accordance with the Valve Setting Procedure. Quarterly Waterf low Alarm Test Procedure Testing of the system waterflow alarms must be performed quarterly. To test the waterflow alarm, open the Alarm Test Valve, which will allow a flow of water to the Pressure Alarm Switch and/or Water Motor Alarm. Upon sat- isfactory completion of the test, close the Alarm Test Valve. TFPI 420 Page 13 of 14 Quarterly Supervisory Low Pressure Alarm Test Procedure Proper operation of the Supervisory Low Pressure Alarm Switch must be performed quarterly as follows: Step 1. Crack open the System Main Drain Valve for the Riser Check Valve (Item P7, Figure 3A) to slowly relieve su- pervisory air pressure from the system. Verify that the Supervisory Low Pres- sure Alarm Switch is operational and that the low pressure set point is ap- proximately 5 psi (0,34 bar). Step 2. Close the System Main Drain Valve (Item P7, Figure 3A) and allow the system supervisory pressure of 10 ± 2 psi (0,69 ± 0,14 bar) to be automatical- ly re-established. The Supervisory Low Pressure Alarm Switch should return to its "normal" condition. Pressure Relief Valve Maintenance Over-pressurization of the system pip- ing with air will result in the opening of the Pressure Relief Valve (Item P4, Fig. 3A). If the Relief Valve continues to bleed air after the system pressure has been reduced to its normal su- pervisory pressure range of 10 ± 2 psi (0,69 ± 0,14 bar), most likely debris has become lodged in the seating area. To help clean the seating area, slowly pull up on the ring at the top of the Relief Valve to allow a full flow of air through the Relief Valve, and then release the ring to allow the Relief Valve to snap closed. Repeat the cleaning procedure as necessary. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure The DV-5 Deluge Valve with Single In- terlock Preaction Electric Actuation trim can be ordered pre-trimmed or non-assembled as separate items. For non-assembled the following items must be ordered separately: DV-5 Deluge Valve CF-11 FR Riser Check Valve Couplings Single Interlock Preaction Electric Actuation Trim, Semi-Preassem bled Supervisory Air Supply Dry Pilot Air Supply Accessories NOTE: 1-1/2 inch (DN40) risers utilize a 2 inch (DN50) Model CV-1FR Riser Check Valve connected to the 1-1/2 inch (DN40) DV-5 Deluge Valve by a 2 x 1-1/2 inch Figure 716 Reducing Coupling. Replacement Trim Parts Specify: (description) for use with DV-5 Deluge Valve, P/N (see Figure 3A) Deluge Valve (Select One) P/Ns are for American Standard Groove x Groove Connections, and Threaded Ports. For other configu- rations refer to Technical Data Sheet TFP1305. Specify: (size) DV-5 Groove x Groove Deluge Valve, P/N (specify): 1-1/2 Inch .................P/N 52-477-1-919 2 Inch ....................P/N 52-477-1-910 3 Inch ....................P/N 52-477-1-912 4 Inch ....................P/N 52-477-1-913 6 Inch ....................P/N 52-477-1-915 8 Inch ....................PIN 52-477-1-916 Riser Check Valve (Select One) P/Ns are for American Standard Grooved Connections. For other con- figurations refer to Technical Data Sheet TFP950 for the Groove x Groove Model CV-1FR Riser Check Valve. Specify: (size), Model CV-1FR Groove x Groove Riser Check Valve, P/N (specify): 2 Inch ...................P/N 59-590-1-020 3 Inch ...................P/N 59-590-1-030 4 Inch ...................P/N 59-590-1-040 6 Inch ...................PIN 59-590-1-060 8 Inch ...................P/N 59-590-1-080 NOTE: For 1-1/2 inch (DN40) risers, use the 2 inch (DN50) Riser Check Valve. Coupling (Select One) P/Ns are for American Standard Grooved Connections. For other con- figurations and finishes refer to Tech- nical Data Sheet TFP1830 or TFP1880. A coupling to attach the Riser Check Valve to the outlet of the Deluge Valve must be separately ordered. Specify: (Size), (Figure #), painted, (description), P/N (specify). For 1-1/2 inch risers, or- der an additional Reducing Coupling for the outlet of the 2 inch Riser Check Valve. 2 x 1-1/2 Inch Figure 716 Painted Reducing Coupling. . . . PIN 7162015ES 2 Inch Figure 772 Painted Rigid Coupling ........PIN 77220ASC 3 Inch Figure 772 Painted Rigid coupling ........P/N 77230ASC 4 Inch Figure 772 Painted Rigid Coupling ........P/N 77240ASC 6 Inch Figure 772 Painted Rigid Coupling ........P/N 77260ASC 8 Inch Figure 772 Painted Rigid Coupling ........P/N 77280ASC Preaction Trim (Select One) Specify: (Size and finish - galvanized is standard) Semi-Preassembled Su- pervised Single Interlock Preaction System With Electric Actuation Trim for DV-5 Deluge Valves, P/N (specify): 1-1/2 & 2 Inch Galvanized . . . . P/N 52-478-2-119 1-1/2 & 2 Inch Black.........P/N 52-478-1-119 3 Inch Galvanized ..........P/N 52-478-2-116 3 Inch Black ...............P/N 52-478-1-116 4, 6 & 8 Inch Galvanized .....P/N 52-478-2-113 4, 6 & 8 Inch Black ..........P/N 52-478-1-113 Supervisory Air Supply (Select One) A device capable of maintaining a nom- inal system air or nitrogen pressure of nominal 10 psi (0,69 bar) must be sepa- rately ordered. Specify: (Model and de- scription), P/N (specify): Model AMD-1 Air Maintenance Device (TFP1221) ..........P/N 52-324-2-002 Model AMD-3 Nitrogen Maintenance Device (1FP1241) ..........PIN 52-328-2-001 Model G16AC812 Automatic Supervisory Air Supply (TFP1620) .......PIN 52-150-1-001 Solenoid Valve (Select One) A Solenoid Valve compatible with the anticipated maximum water supply pressure must be ordered separately. Refer to Technical Data Sheet TFP2180 for other voltage ratings and NEMA classifications. Specify: 24 VDC, NEMA 2, 4, and 4X, (specify 175 or 250 psi) Solenoid Valve, P/N (specify): 175 psi ...................P/N 52-287-1-024 250 psi ...................P/N 52-287-1-124 Pre-Trimmed DV-5 Assembly with Butterfly Valve Specify: (size), G x G End Connection, Pre-Trimmed DV-5 Assembly with But- terfly Valve, P/N (specify): 1-1/2 Inch G x G ...........P/N 52-916-0-11AP 2 Inch G x G ..............P/N 52-926-0-11AP 3 Inch G x G ..............P/N 52-936-0-1AP 4 Inch G x G ..............P/N 52-946-0-1AP 6 Inch G x G ..............P/N 52-966-0-1AP 8 Inch G x G ..............P/N 52-986-0-1AP Pre-Trimmed DV-5 Assembly without Butterfly Valve Specify: (specify size), (specify) End Connection, Pre-trimmed DV-5 As- sembly without Butterfly Valve, P/N (specify): 3 Inch F x G ..............P/N 52-936-2-1AP 4 Inch F x G ..............P/N 52-946-2-1AP 6 Inch F x G ..............P/N 52-966-2-1AP 8 Inch F x G ..............P/N 52-986-2-1AP Accessories (As Needed) Specify: (description), P/N (specify): 600 psi Water Pressure Gauge...................P/N 92-343-1-004 Model WMA-1 Water Motor Alarm (TFP921)...........P/N 52-630-1-001P TFPI 420 Page 14 of 14 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright© 2014 Tyco Fire Products, LP. All rights reserved. tqco Fire Protection Products tqca Worldwide i Fire Protection Contacts I www.tyco-fire.com Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/ps1112 (80,6 LPM/barl'2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 WF Fl 2-7/8 (73,0 mm) DIA. -. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2° 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15or20 RECESSED ESCUTCHEON CROSS SECTION 1 7/16 (11,1 mm) I NOMINAL MAKE-IN 2 (50,8 mm) 1/2 NPT** UPRIGHT \J (50,8 mm) f 1 3/8 (34,9 mm) DEFLECTOR * PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE / CH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER / FITTING 5/8 (15,9 mm) LJ1 FLUSH 3/8±5/16 (9,5±7,9 mm) 17 MOUNTING / 1/81,J SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" (7,9±6,4 mm) FLUSH \ I 1/2(12,7mm) 7\__(3,2 mm) __ -,,>, MOUNTING /8" J SURFACE \J/ \ CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I I SPRINKLER TEMPERATURE FINISH J- RATINGS SIN 1 NATURAL BRASS I 370 I 5.6K UPRIGHT (1/2- NPT) TY313 3 PURE WHITE (RAL9010)** POLYESTER 371 5.6K PENDENT (1/2" NPT) TY323 POLYESTER SIGNAL WHITE (RAL9003) Use suffix °I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - ** Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200° (93°C) F 286 286°F (141°C) Limited Warranty For warranty terms and Conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (Specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (Specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products A TO chmidt Fire Protection Co., Inc. 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123 (858) 279-6122 • FAX (858) 279-3583 VIASAT BUILDING-12 2501 Gateway Road Carlsbad, CA 92111 Preaction Sprinklers Detection and Control SUBMITTAL PACKAGE Design by: Gordon E. Swope SET (NICET Level-IV #078621) (619) 871-9753 sfpgordoncgmaiI.com Date February 27, 2018 (E)POTTER PFC-441ORC The Symbol of Protection RELEASING CONTROL PANEL Dimensions: 18 ¼" x 14 '/2" x 4 /4" UL and ULC Listed, FM Approved, NYMEA Accepted, CSFM Approved, CE Marked, and RoHS Compliant. General Description The Potter Model PFC-4410RC is aflexible multi-hazard releasing control panel that is well suited for a number of applications. The PFC-4410RC is listed for use with pre-action and deluge sprinkler suppression systems and agent based fire suppression systems. The panel utilizes a microprocessor-based system that has 24 Standard Programs, which covers a majority of installations. The simple to follow Menu Structure programs the entire system in a matter of minutes. In addition to the Standard Programs, the panel allows custom programming to accommodate any installation. Multi-Hazard Operation Four Class B Initiating Circuits Two Class B Supervisory Circuits ** Four Class B Output Circuits Programmable Cross Zoning Supervised Microprocessor 32 Character Alpha-Numeric LCD Display Custom Banner Message and Zone Description text Custom Zone Description Text On Board Menu Driven Programming Controls Releasing Circuits Protected From False Activation Continuous or Timed Discharge 40 Event History Buffer Wallctest with Automatic Time-out Alarm, Trouble Supervisory, and Waterfiow relays Optional Class A Initiating Zone and output module 34 character LED supplemental display 24 Standard Programs in Panel Memory Password Protection for all Programming 24 Hour Clock Suitable for agent or water-based extinguishing Programmable pre-discharge timers* One Class B Abort circuit* (Defaults to additional supervisory zone in water based mode.) Four Abort modes* * Available in Chemical mode only ** One zone programmable as abort in chemical mode. The panel is Ninth Edition UL listed, UILC listed, Factory Mutual, California State Fire Marshal (CSFM), New York Materials Equipment Acceptance (MEA) Approved, CE Marked, and RoHS Compliant. The PFC-4410RC is housed in a durable steel cabinet with removable door and key lock. The panel is available in either a red or white finish and an optional flush mount trim ring is available. The cabinet contains knockouts on the side, back and top of the cabinet to ease installation. In addition, the cabinet will house up to 18 amp-hour batteries that will provide in excess of 90 hours of standby power. Ordering Information Model Number Description Stock Number PFC-4410RC 4 Zone Releasing Control (White Cabinet) 3006144 PFC-4410RC 4 Zone Releasing Control (Red Cabinet) 3006142 PFC-4410RC-PCA Replacement Motherboard 3006230 PFC-TW Bezel for Semi-Flush Mounting (White) 5090157 PFC-TR Bezel for Semi-Flush Mounting (Red) 5090155 BT-80 Battery, 12V 8AH for 24 hour standby (2 Req'd) 5130084 BT-120 Battery, 12V 12AH for 24 hour standby (2 Req'd) 5130090 BT-180 Battery, 12V, 18AH for 90 hour standby (2 Req'd) 5130086 CA2Z 2 Zone Class A Initiating Circuit Module 3006013 CAM Class A Indicating Circuit Module 3005300 ARM-44 Relay Module for PFC-4410RC 3006221 ARM-2 Auxiliary Relay Module 3004725 RA-4410RC Remote Annunciator 3006400 BB-RA-44R Surface Mount Back Box for RA-4410RC (Red) 3006401 PotterElectric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-9561211• Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG 95401250 - REV C PAGE I OF 2 3/14 (E)POTTER The Symbol of Protection Architects/Engineers Specifications The control panel for the extinguishing agent releasing system shall be a microprocessor based control capable of protecting multiple hazards in one control panel. It shall be Underwriters Laboratories Inc. listed under Standard 864 Ninth Edition and Underwriters Laboratories of Canada for Local Control Units for Releasing Service. The control shall also be approved by Factory Mutual Research Corporation and be compliant with the requirements of NFPA-72 (Local: A, M, SS service types; DAC and NC signaling type) and NFPA12, NFPA12A, NFPA-13, NFPA-15, NFPA-16, NFPA-17, NFPA-17A, NFPA-750, and NFPA-2001. The control shall be housed in an 18 gauge steel cabinet that has a hinged, removable door with a key lock. The finish shall be baked enamel and available in red or off-white with contrasting trim and logo. An optional matching bezel should be available for semi-flush mounting. The cabinet shall have adequate space to house 18 AH standby batteries capable of operating the system for at least 90 hours. The control shall include a fully supervised integral power supply/battery charger capable of providing 200mA to the auxiliary power circuit. It shall also be capable of providing 2.5 Amps to all releasing and notification appliance circuits combined. All initiating, output and auxiliary power circuits shall be power limited. The control shall have a 32 character (16 characters, 2 lines) backlit LCD display and a 34 LED supplemental display. All diagnostic and alarm event information shall be viewable in text form on this display. A field programmable custom banner message with the current date and time shall be displayed when no current alarm or diagnostic information exists. All operational features of the control panel shall be field programmable using menu driven selections on the alpha-numeric display and on board controls. No special programmer will be required and jumpers or switches to configure operational features shall not be permitted. Alarm and trouble indications shall resound when required. The control panel shall be equipped with 24 programs built into the panel memory, 15 for water based extinguishing and 9 for agent extinguishing. In addition, the panel shall have the ability to add custom programs. All programming functions shall be password protected. The control shall have four fully supervised Class B (Style B) initiating circuits capable of supporting the operation of 25 compatible 2-wire smoke detectors on each circuit. The individual circuits shall be selectable through the programming sequence to operate in one of the following modes: Conventional, PFC-44 1ORC RELEASING CONTROL PANEL Waterfiow, Linear Heat Detection (up to 700 ohms per zone), Manual Release, Low Air Alarm, Supervisory, Tamper, Low Air or High Air. Optional Class A modules, CA2Z, may be added for Class A operation. The panel shall have a Low Air Zone that creates a supervisory condition and can be mapped to a release output. The control shall have two fully supervised Class B (Style B) supervisory circuits. These circuits shall be selectable through the programming sequence to operate in one of the following modes: Supervisory, Tamper, Low Air or High Air. The control shall have one fully supervised class B (style B) Abort circuit with 4 different operating modes, ULI, WI, and NYC, and 30 second. The control shall have four fully supervised Class B (Style Y) output circuits. These circuits shall be selectable through the programming sequence to operate as one of the following: Alarm Notification Appliance, Supervisory Notification Appliance, Trouble Notification Appliance or Releasing. The optional CAM module may be added to convert the outputs to Class A. The panel shall have an RS-485 output and auxiliary power outputs for connection and supervision of up to 4 remote annunciators or an ARM-44 Relay Module and 3 annunciators. The releasing circuits shall be supervised for short circuit conditions and shall be programmable for cross zoning operation when required. The discharge timer for these releasing circuits shall be programmable for times of 7, 8, 9, 10, 20 minutes or continuous. All initiating and output circuits shall be capable of being individually disabled or enabled. In addition, when in the agent extinguishing mode there shall be a pre-discharge timer adjustable from 0-60 seconds from an alarm zone or 0-30 seconds from a manual release zone. The control shall have a test mode that will automatically disable all releasing circuits. The test mode shall operate in such a manner as to automatically reset the initiating circuit and indicating circuits after detecting each alarm condition initiated by the test. All testing shall be recorded in the 40 event history buffer. The test mode will automatically terminate after twenty minutes of inactivity. The control shall have four integral relay contacts rated 3 Amps at 30 VDC for connection to external auxiliary equipment. One relay shall operate when an alarm condition occurs, another when a trouble signal occurs, the third when a supervisory condition occurs, and the fourth during a waterfiow condition. UL and ULC Listed, FM Approved, NYMEA Accepted, CSFM Approved, CE Marked and RoHS Compliant PRINTED IN USA MFG #5401250 - REV C PAGE 2 OF 2 3/14 (E)POTTER CLASS A INITIATING The Symbol of Protection DEVICE MODULE UL Listed: Option for use with the PFC-4410RC Series Transient Protected Built In 5.1k End Of Line Resistor PC Board Assembly: Mounts to PFC-4410RC Panel stand-offs Stock No. 3006013 The Model CA2Z Class A Module is designed to be used with the PFC- The module is to be mounted in the upper right hand corner of the panel. 4410RC Fire Control Releasing Panel to convert from two (Class B) Connection to the panel is made via the 8 pin header mounted on the initiating device circuits to two (Class A) circuits. back side of the CA2Z. Mounting /SUP + SLIP - ZONE I ZONE2 ZONE ZONE4 ~G (D S S S @ (!§) S~ 0 00 0 CA2Z CA2Z MODULE MODULE NO.2 NO.1 (IF USED) I -I J2 I-I J2 Typical Wiring PFC-4410RC ;ONE 3 PC BOARD 1 2 3 4 I 2 3 4__ CA2Z H CA2Z DWG# 3527.1 Potter Electric Signal Company •2081 Craig Road, St. Louis, MO, 63146-4161Phone: 800-325-3936/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. 95401025 - REV F PAGE 1 OF I 8/06 f SYSTEM 4 SENSOR® 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors \ are inappropriate. 15"rc Features Multiple configurations for installations: - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang —3.5"and 40ctag0na1 - 4" square with square to round plaster ring Reversible mounting bracket Agency Listings LISTED APPROVED S2101 3016008 0S630 7270-16530167 Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 1 4-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603,5621, and 5623: 100°F(38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 60z. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage I Contact 6-125VAC / 3A Ratings 6-28VDC / 1A 125VDC / 0.3A 250VDC/0.1A InputTerminals 14-22 AWG 0 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5601P Single None 135°F (57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYSTEM 3825 SENSOR"- Ohio Avenue • St. Charles, IL 60174 ©20135ysten1 Sensor , Phone. 800-SENSOR2 • Fax: 630-377-64 95 - for current product information, including the latest version at this data sheet. www.systemsensor.com SPDS30001 • 7/13 Series MT and MT Strobe Multitone Electronic Appliances 19 SERIES MT STROBE MT4-115-WH SERIES MT-12/24 Description: The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panel incorporating the Wheelock Patented Sync Protocol. The MT Strobes are designed forADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and UL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy. Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, 12VDC or 24VDC. Strobe versions are specific for either 12VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave- rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances. FM MEA " APPROVED E5946 151-92-E 7135-0785:118 (MT4) 7125-0785:155 (MT) 7125-0758:156 (MTWP) Features: Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information Designed to meet or exceed ADAINFPA/UFC/ANSI Standards and Accessibility Guidelines Complies with OSHA 29, Part 1910.165 Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable candela settings at 15/30/75/110cd or with single candela 1575cd strobes. Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR No additional trimplate required for flush mounting For Weatherproof MTWP See Data Sheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFUllY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" (16-33v for 24VDC units and 8-17.5v for 12VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. All candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-1 2/24, MTWP and MT4 models and listed for outdoor use at -31 "F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. MT Audible is UL Standard 464 Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ONI0.25 sec. OFF/Repeat CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HI/LO 1000/800 Hz (0.25 sec. ON/Alternate) Table 1: dBA and Current Ratings for Multitone Audible Portion RMS Current (amps) dBA@ lOft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 120 VAC HI Output STD Output HI Output STD Output HI STD HI Output STD Output HI Output STD Output HI Output STD Output © 24 VDC UL max" @ 24 VDC UL max" 24 VDC UL max* @ 24 VDC UL max" --- UL max" -- UL max" Hom 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.050 0.042 92 87 90 77 85 82 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 0.041 0.039 86 80 85 69 82 75 March Time 0.067 0.104 0.033 0.038 0.109 0.142 0.023 Hom 0.034 0.050 0.040 89 84 89 74 85 79 Code-3 Hom 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 82 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 79 75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 85 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 0.041 89 84 89 75 85 82 HI/LO 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 0.042 0.039 86 81 86 71 82 79 Table 2: Strobe Current Ratings RMS Current (amps) Model MT-121575 MT-241575 MTWP-2475 MT-24MCW Candela 1575cd 1575cd 180cd 15cd 30cd 75cd llocd ©24VDC 0.152 0.060 - 0.094 0.041 0.063 .0.109 0.140 UL max* 1 0.255 0.090 0.138 0.060 0.092 0.165 0.220 Note: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (1 6-33v for 24v units). For WobethéUL mácUrféit isuUãlIy at - the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams (for all models) MT SIGNAL AUDIBLE SIGNAL AND STROBE AUDIBLE SIGNAL AND STROBE OPERATE OPERATE INDEPENDENTLY IN UNISON. RED AND BLACK SHUNT-WiRES FROM + ARE SUPPLIED. PRECEDING + + TONEXI PRECEONG + APPLIANCE POLE PRECEDING + TO NEXT COOPERWHEELOC APPLIANCEOR OIIOIOLEOR ____________________________ - flUOIBLEOR FROM DSM. - EOLR EACP APPLIANCE RED FROM PRECEDING POWER SUPPUES OR EOLR OP PU EU RE FACP TO N __P H _________ STNOOROR COOPEUWOERIORE OR FACP - APPLIANCE OR MCP - BURR SIGNAL IJ-tJl +- 0 STROBE AUDIBLE STROBE AUDIBLE Specifications and Ordering Information Model Number Order Code Input Voltage Rated Candela Mounting Options*** Agency Approvals UL MEA CSFM FM BFP MT-12/24-R 5023 12/24 - D,E,F,L,M,O,P,R X X X X X MT-12/24-W 5024 12/24 - D,E,F,L,M,O,P,R X X X X X MT241575WFR# 8422 24 15(75onAXIS) D,E,F,L,M,O,P,R X X X X - MT-24MCW-FR 3301 24 15/30/75/110 D,E,F,L,M,O,P,R X - X - - MT-24MCW-FW 3303 24 15/30/75/110 D,E,F,L,M,O,P,R X - X - - MT24MCWAR*** 3304 24 15/30/75/110 D,E,F,L,M,O,P,R X - X - - MT121575WFR# 8421 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X - MT-121575W-NW 9747 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X - MTWP2475WFR** 8420 24 180 @ 77°F (25°C) M X X X X - MTWP2475WNW** 9744 24 180 @ 77°F (25°C) M X X X X - MT4-115-R 6223 120 VAC - D,E,J,K,N,O,R X X X - X MT4-115-S 6142 120 VAC - D,E,J,K,N,O,R X X X - X MT4-115-WH-VFR## 6224 120 VAC 15 D,E,J,K,N,O,R X X X - X MT4-12/24-R 5308 12/24 - D,E,J,K,N,O,R X X X X - MT4-12/24-S 7997 12/24 - D,E,J,K,N,O,R X X X X - NOTE: **MTWP2475W is Weatherproof and rated for 180 cd © 77°F (25°C). See Data Sheet S9004 or Installation Instruction P84150. ***For additional information on mounting please refer to Data Sheet S7000. #1575 strobes are UL Listed for 15cd with 75cd on AXIS. Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. *** "A" Stands for Agent Lettering. WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-12124, P84155 MTw/Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often arid in cordanWithlocaIstateand federaVco"des regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). S2000 MT 06/11 Notification Architects and Engineers Specifications - - The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall be able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels.- STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30/75/110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-12/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. NEAM I'fl,1.I.l WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY (E)POTTER The Symbol of Protection These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (10 1mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. BELLS PBA-AC & MBA-DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8' (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -400 to 150°F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells -4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-l. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC - St. Louis, MO, Phone: 866-572-3005/Cnada 888-882-1833• www.pottersignal.com PRINTED IN USA MFG. 95400776 - REV Y- 1 PAGE 1 OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2' conduit entrance 53/4" - (146) L I1 33/8" 15/8" (86) 4 1/4" ((08) SWISS 776-2 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 WHITE (IN) WHITE (OUT) FROM CONTROL PA, A I4EL OR PRECEDING BELL BLACK (011fl BLACK (IN) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWGO 776-I DWG# 716.3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local Al-U. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong), Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). K. WWI Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 2 OF 2 01/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0170 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Model PFC-4410RC and PFC-4410ARC fire alarm control units. Automatic, manual, noncoded, local, remote station, central station, releasing device, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. Minimum system components: PFC-4410RC Control Unit PFC-441OARC Control Unit with LED annunciator Suitable for use with the following modules: RA-4410RC, CA2Z, CAM, ARM-1, ARM-2, *ARM44 and SG-32. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with separately listed voice evacuation systems. Refer to listee's Installation Instruction Manual for details. These control units do not generate a Temporal Pattern Signal. If the distinctive three-pulse Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Model PFC-4410RC control unit meets the requirements of UL Standard 864, 9th edition. Model PFC-4410ARC control unit meets the requirements of UL Standard 864, 8th edition. NOTE: Combined with 7170-0328:171 *Rev 06-18-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued:- July 01, 2017 - ------ Listing Expires —June30,.2018 ... Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1653:0167 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models 5601, 5601P, 5602, 5621, and 5622 combination fixed-temperature and rate-of-rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models 5601, 5601 P, 5603, 5621 & 5623 have a fixed temperature of 135°F. Models 5602, 5604, 5622, & 5624 have a fixed temperature of 194°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details and UL directory for dimensions. NOTE: Formerly 7270-1209:227 06-20-05 This listing the test is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued -July 01--2047-- - - Listing-Expires-.. .- June 3O1018 - Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0155 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models MT Multitone Sync *horn/strobes Models may be followed by 12 or 24 for voltage, followed by strobe/candela rating, followed by W for wall mount. Units may be followed by suffixes to designate lens lettering and plate color. The series can provide one of eight tone outputs. Model MT-24MCW, may be followed by a letter indicating enclosure color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 voltage: 8-17.5 VDC 24 voltage: 16-33 VDC Flash rate: 60 flashes/mm Candela: Models 1575: 15cd (75cd on axis) Models 75-.75cd Models MCW: lscd, 30cd, 75cd or 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For wall mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as *horn/strobes suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only. For synchronized strobes, Models SM-12/24, or DSM-12/24 Sync Module (CSFM Listing No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. These units can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Rev. 05-25-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued:......- July, O1,2O4-7-- Listing-ExpiFes- ...... June-3O-2Oi8 -. Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ..... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 'V4 LISTING SERVICE LISTING No. 7135-0328:0119 Page 1 of 1 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models 513624-153075, 513624-75110, PBA246, PBA248, PBA2410, PBA1206, PBA1208, PBA12010, *PBD..126 *pBD..128 *pBD.1210 *PBD..246 *pBD.248 * PBD-2410 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 6', 8" and 10". Models MBA-6, -8 and -10 bells, suitable for outdoor use when used with Model BBX-1 backbox. Refer to listee's data sheet for detailed product description and operational considerations. RATING: PBA-246, -248, -2410: 24 VAC PBA-1206, -1208, -12010: 120 VAC MBA-6, -8, -10: 12 or 24 VDC *pBD.126 -128, -1210: 12VDC, .12A *PBD.246 -248, -2410: 24VDC, .06A INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Revision 01-31-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued --JuAy.O12Oi7- - .--- Listing-Expires- - -June-30,20118 - Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division