Loading...
HomeMy WebLinkAbout2501 GATEWAY RD; BLDG 12; FPC2018-0079; PermitPrint Date: 02/15/2022 Job Address: 2501 GATEWAY RD, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132501100 Track #: Valuation: $11,652,165.46 Lot #: Occupancy Group: Project #: DEV2016-0015 #of Dwelling Units: Plan #: Permit No: FPC2018-0079 Status: Closed - Finaled Applied: 03/07/2018 Issued: 06/13/2018 Finaled Close Out: 05/25/2021 (ity of Carlsbad - Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: VIASAT BRESSI RANCH CAMPUS Description: VIASAT: BLDG 12 -FIRE ALARM INSTALLATION OF NEW SYSTEM 90,054 SF OFFICE COLD SHELL W/ SUBTERR GARAGE Inspector: Final Inspection: FPContractor: WEST COAST FIRE AND INTEGRATION INC 3199 AIRPORT LOOP DR, #STE D COSTA MESA, CA 92626-3414 (714) 957-5750 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov West Coast Fire & Integration Fire Alarm • Access Control • Security • CCTV • Nurse Call • Voice/Data 01, VIASAT BUILDING 12 2501 Gateway Road Carlsbad, CA Job# 18-029-00 Fire Alarm System Product Data SALES • DESIGN • INSTALLATION • SERVICE 3199-D Airport Loop Drive Phone (714) 957-5750 Lic.# CIO-989173 Costa Mesa, CA. 92626 Fax (714) 957-5749 ACO# 7407 www.westcoastfireinc.com DN-7070:L A-10 NFS2-3030 NOTI Fl ER® Intelligent Addressable (a Fire Alarm System by Honeywell ntelligentaFire AlarmiControlI nr General 0 The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these appli- cations. The NFS2-3030 is part of the ONYX® Series of prod- ucts from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is config- ured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelli- gent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situa- tion, fire progression, and evacuation details. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments; wireless fire protection; and many additional options. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when a marine-listed ver- sion is used with marine-listed compatible equipment. See DN-60688. Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher). One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. Wireless fire protection using SWIFT Smart Wireless Inte- grated Fire Technology. See DN-60820. Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. - Detectors can be any mix of ion, photo, thermal, or multi- sensor; wireless detectors are available for use with the FWSG. - Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. Large 16 line, 640 character LCD backlit display or use display-less as a network node. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online/offline program option. NFS2-3030 (left) and NFS2-3030 with DVC audio option (right) With built-in Degraded Mode operation, the system is capa- ble of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. EIA-485 annunciators, including custom graphics. History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. Advanced history filters allow sorting by event, time, date, or address. Alarm Verification selection per point, with automatic counter. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM Positive Alarm Sequence (PAS) Presignal. Silence Inhibit and Auto Silence timer options. Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Up to 1000 powerful Boolean logic equations. Supports SCS Series smoke control system in both HVAC and FSCS modes. FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. EIA-232 printer port. EIA-485 annunciator port. a, S DN-70701 • 09/09/2014 - Page 1 of 8 SLC Intelligent Loop [EEi1.........1 — - — H FAPT-851 NBG-12LX -------- Upto32 LCD-160 LCD2-80 remote I FSL-751 I FSA-8000 displays I I etc. EIA-485 I I C FWSG XP6/10 110 Modules FMM-1 FRM-1 IDC Relay Contact ElA-485 Optional 2048-point UDACT Dual phone lines to Central Station EIA-232 3072 annunciator/control points ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics IM 88 CPU2-3030D display or CPU2-3030ND C 640-CHARACTER DIsPLAY FEATURES Backlit, 640-character display. Program keypad: full QWERTY keypad. Up to nine users, each with a password and selectable access levels. 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- rity; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLAsHScANO INTELLIGENT FEATURES Polls up to 318 devices on each loop in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Sensitivity levels: - Ion —0.5 to 2.50/6/foot obscuration. - Photo —0.5 to 2.35%/foot obscuration. - Laser (VIEW®) - 0.02 to 2.00/o/foot obscuration. - Acclimate PlusTM - 0.5 to 4.00/./foot obscuration. - IntelliQuad - 1.0 to 4.00/./foot obscuration. - lntelliQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. Programmable activation of sounder/relay bases during alarm or pre-alarm. Read Status displays the level of detector cleanliness. FSL-751 VIEW (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. Sample System Options S NFS2-3030 (f Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier PRN Series Printer NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. Page 2 of 8— DN-70701 • 09/09/2014 FAPT-851 ACCLIMATE PLUS TM Low-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FSA -8000 INTELLIGENT FAAST DETECTOR Connects directly to the SLC loop of compatible ONYX series panels Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. • Advanced algorithms reject common nuisance conditions FCO-851 INTELLIQUADTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE Interface to industry-standard linear scale 4-20 mA sensors. Five programmable thresholds. FM Approved, Class 6320 (Stationary Gas Sensors/ Detectors). SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series). Solid state message generation. Hard-wired voice control module options. Firefighter telephone option. 30- to 120-watt analog amplifiers (AA Series) Backup tone generator and amplifier option. FlashScan® Exclusive World-Leading Detector Protocol At the heart of the NFS2-3030 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. As well as giving quick identification of an active input device, this protocol can also activate many output devices in a frac- tion of the time required by competitive protocols. This high speed also allows the NFS2-3030 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection capability. These complex algorithms require many calcula- tions on each reading of each detector, and are made possible by the very high-speed microcomputer used by the NFS2- 3030. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Maintenance Warnings. When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm. Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing. A patented feature of ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit. The NFS2-3030, like all NOTIFIER intelligent panels, has the exclusive feature of program cre- S S DN-70701 • 09/09/2014 - Page 3 of 8 S ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS2-3030 simultaneously monitors other (already installed) points for alarm conditions. VERIFIRE® TOOLS VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows® based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-3030 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Product Line Information "Configuration Guidelines" on page 4 "Main System Components" on page 4 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 5 "Compatible Devices, ElA-232 Ports" on page 5 "Compatible Devices, ElA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 5 "Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On single-FACP systems (one NFS2-3030D), the display option is the CPU2-30300. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as follows. MAIN SYSTEM COMPONENTS C131.112-30301): NFS2-3030 Primary Display. CPU2-3030D ships with keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control key- pad. CPU2-3030 is a central processing unit and requires an AMPS-24(E) power supply. Non-English versions are avail- able: CPU2-3030D-FR, CPU2-3030D-HE, CPU2-3030D-KO, CPU2-3030D-PO, CPU2-3030D-SC, CPU2-3030D-SP, CPU2- 303013-TC, and CPU2-3030D-TH. For English Marine applica- tions order CPU2-3030D-M; for non-English Marine applica- tions order CPU2-3030D-M and the appropriate KP-KIT-XX. (See DN-60688.) CPU2-3030ND: CPU2-3030 without display. Non-English ver- sions are available: CPU2-3030ND-FR, CPU2-3030ND-HE, CPU2-3030ND-KO, CPU2-3030ND-PO, CPU2-3030ND-SC, CPU2-3030ND-SP, CPU2-3030ND-TC. LCM-320: Loop Control Module. Provides one SLC. NFS2- 3030 supports up to five LCM-320s and five LEM-320 expand- ers for a total of ten SLCs. See DN-6881. LEM-320: Loop Expander Module. Expands an LCM-320. See DN-6881. SAMPLE SYSTEM: Four-loop NFS2-3030 with display: CPU2-3030D, DP-DISP two BMP-1s, CHS-M3, two LCM- 320s, two LEM-320s, AMPS-24, SBB-A4, DR-A4, BP2-4, BB- 100, batteries. NETWORKING OPTIONS NCA-2: Network Control Annunciator, 640 characters. An alternate primary display for CPU2-3030 can be provided by the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary display enables non-English languages. On network systems (two or more networked fire panel nodes), one network display (either NCA-2, NCS, or ONYXWorks) is required for every sys- tem. On network systems, the NCA-2 connects (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DISP, ADP-413, or in an annunciator box, such as the ABS-21). In CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting. Non-English versions are available: NCA-2-FR, NCA-2-HE, NCA-2-KO, NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2-TC, NCA-2-TH. For marine applications, order NCA-2-M; for non-English marine applications order NCA-2-M and appropriate KP-KIT-XX. See DN-7047. NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 6861. HS-NCM-W/MF/SFIWMFIWSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See ON- 6971. ONYXWorks: UL-listed graphics PC workstation, ONYXWorks GUI software, and computer hardware. See DN-7048 for spe- cific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- GW-EM.) See DN-60499. NWS-3: NOTI.FIRE.NETTM Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See ON- 605 76. VESDA-HLI-GW: VESDAnet high-level interface gateway. See ON-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTIsFIREsNET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES AMPS-24(E): One required for each NFS2-3030. Addressable power supply and battery charger with two 24 VDC outputs. Addressable by any FlashScan® or CLIP mode FACR Charges 7 to 200 AH batteries. Occupies up to five addresses on an SLC, depending on configuration. Primary input power for panel. See ON-6883. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger. See ON-6927. BAT Series: Batteries. AMPS-24 uses two 12 volt, 7 to 200 AH batteries. See DN-6933. Page 4 of 8— D14-70701 • 09/09/2014 AUDIO OPTIONS NOTE: See "Enclosures, Chassis, and Dress Plates" on page 6 for mounting hardware. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60585. DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See DN- 7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAA2/DAX Series amplifiers. See DN-60633. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): SOW, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly. See DN-7045. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (AM-1) dress panel or CAB-RM/-RMR (AM-iSA) stand-alone cabinets. See DN-6 728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 Vrms. AA-100 is 100 watts, 70.7 Vrms. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -134 backbox (consumes one row). Includes audio input and ampli- fied output supervision, backup input, and automatic switcho- ver to backup tone. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running 5A4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN- 60257. COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. V54095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEvicEs, EIA -485 PORTS ACM-24AT: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT; expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-160: Liquid Crystal Display annunciator, 160-character backlit. Can store character sets for multiple languages. Sup- ports Canadian requirements. See DN-6940. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD2-80 (DN-60548). SCS Series: Smoke control station; eight (expandable to 16) circuits. See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (as in single-address mode applications) or in CHS- M3 position. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60688. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts on a CHS-4 series chassis within NFS2-3030. COMPATIBLE INTELLIGENT DEVICES FWSG Wireless SWIFT Gateway: Addressable gateway sup- ports wireless SLC devices. Not appropriate for ULC applica- tions. See DN-60820. FSA-8000: Intelligent FAAST Fire Alarm Aspiration Sensing Technology®. Intelligent aspirating smoke detector. For Cana- dian applications, order FSA-8000A. See DN-60792. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-2005: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6985. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-604 12. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSI-851: Low-profile FlashScan ionization detector. See DN- 6985. FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. DN-70701 • 09/09/2014 - Page 5 of 8 FSP-851 R: Low-profile intelligent photoelectric sensor, remote S test capable. For use with DNR(W). See DN-6935. FSP-8511: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FST-851: FlashScan thermal detector 135°F (57°C). See DN- 6936. FST-851R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate PlusTM low-profile multi-sen- sor detector. See DN-6937. FSL-751: FlashScan VIEW® laser photo detector. See DN- 6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 separately). Replaces FSD-751 PL/FSD- 751 RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224B1: Isolator base for low-profile detectors. See DN- 60054. B210LP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501: European-style, 4(10.16cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. S B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6 720. FDM-1: FlashScan dual monitor module. See DN-6 720. FZM-1: FlashScan two-wire detector monitor module. See DN- 6720. FMM-101: FlashScan miniature monitor module. See DN- 6720. FMM-4-20: FlashScan 4-20 mA protocol monitor module. See DN-60411. FCM-1: FlashScan control module. See DN-6724. FCM-1-REL: FlashScan releasing control module. See DN- 60390. FTM-1: Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See DN-6989. FRM-1: FlashScan relay module. See DN-6724. FDRM-1: FlashScan dual monitor/dual relay module. See ON- 60709. NBG-12LX: Manual pull station, addressable. See DN-6 726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects S intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See DN-6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-3030 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through °D"). Backbox and door ordered separately; requires BP24 battery plate. A trim ring option is available for semi-flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through '0". See DN- 60229. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Order CPU2-3030D-M; for non- English marine applications order CPU2-3030D and appropri- ate KP-KIT-XX. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see ON-60688. CHS-M3: Mounting chassis for CPU2-3030. One required for each CPU2-3030D/3030ND. CA-2: Chassis for FACP control panel when DVC-EM is used with firefighters telephone. Mounts in the top two rows of a CAB-4 series enclosure. DP-DISP: Dress panel for top row in cabinet with CPU2- 3030D installed. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. See DN-7046. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts on the left side of DAA2 chassis. See DN-7046. Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). See DN-7045. Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-04 (below). ADDR-134: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-C4: Three-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-D4: Four-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-04 backbox with the ADDR-04. See DN-7045, DN-6857. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2: Dress Panel used with the CA-2 chassis assembly. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two Page 6 of 8- DN-70701 • 09/09/2014 bays for two ACS annunciators, or for blank plates. See DN- 7045. ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- tors. BMP-1: Blank module for unused module positions. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. BP2-4: Battery plate, required. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers. CHS-4N: Chassis for mounting up to four APS-6Rs. CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. Mounts up to six modules in any CAB-4 series row. BB-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100 AH batteries and power supply, if needed. 30° (76.20 cm) wide x 25° (63.50 cm) high x 7.5' (19.05 cm) deep; depth includes door. BB-200: Backbox for batteries and power supplies. Holds up to four 100 AH batteries (200 AH capacity) and power supply. 30° (76.20 cm) wide x 36° (91.44 cm) high x 7.5° (19.05 cm) deep; depth includes door. ( CB- B Battery Box. The NFS-LBB is used to mount up to two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x 14" (356 mm) high x 7.75° (197 mm) deep. Door: 24.125° (613 mm) wide x 14.25" (362 mm) high; door adds 0.0625" (approx. 1.6 mm) to depth. BB-UZC: Backbox for housing the UZC-256 for applications where the UZC will not fit in panel enclosure. Black; for red, order BB-UZC-R. See DN-3404. SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-3030 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 All batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411IJDAC: Digital alarm communicator. See DN-6 746. IPDACT-2, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for Internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel classis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: V-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red; for black, order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order IPGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits ...........1 expandable to 10 Intelligent detectors..........................................159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones.............................over 2000 ACS annunciators per CPU2-3030 .......................32 address x 64 or 96 points NOTE: The CPU2-3030 can support up to 96 annunciator address points per ACM-24AT/-48A. SPECIFICATIONS Primary Input Power: - AMPS-24:110-120 VAC, 50/60 Hz, 4.5 A maximum. - AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A maximum. DC Output: - Main 24 VDC: Up to 5.0 A - Aux 24 VDC: Up to 5.0 A -5 VDC: Up to 0.15 A. rent draw (tandby/Marm) < CPU2-303ODboard34OA) U2 3030ND boa 2OA AMPS-240 power from secondary power source o) eAA I Manual 51907 for aco draw calculation sheet and details of input and outp ut values.) Battery charger range: 7 AH - 200 AH. Use separate cabinet for batteries over 26 AH. Float Rate: 27.6 V. SHIPPING WEIGHT CPU2-3030D: 5.95 lb (2.70 kg). CPU2-3030ND: 2.90 lb (1.32 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. MEA: 232-06-E. Fire Dept. of New York: COA#61 14. CSFM: 7165-0028:0224 (Commercial). FM Approved. FM6320 Approved. Class 6320 for Gas Detection. City of Chicago. City of Denver. Singapore Productivity and Standards Board (PSB). S S S DN-70701.09/09/2014 - Page 7 of 8 CCCF listed. S . Fire Services Department (Hong Kong). Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in "Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: US Coast Guard 161.002/55/0 (Standard 46 CFR and 161.002). Lloyd's Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-3030 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: • UL 864 (Fire). • UL 1076 (Burglary). • UL 2572 (Mass Notification Systems). (NFS2-3030 version 20 or higher) • LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). • AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). • REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). • PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). Not applicable for FM. S . EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). • (BC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). • CBC 2007 (Seismic). lntelliQuadTM, NOTI.FIRE.NErM, ONYXWorks, and SWIFT are all trademarks; and Acclimate® PIusTM, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc. ©2014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. llflIN & mwiiam All specifications are subject to change without notice. IUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8018— DN-70701 • 09/09/2014 DN-6881:A1 • A-35 LCM-320 and LEM-320 Loop Control and Expander Modules S y Honeywell Intelligent Fire Alarm Control Panels The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER's ONYX® Series of Fire Alarm Control Panels (FACP5) with Signaling Line Circuits (SLCs). The ONYX® Series NFS-6401NF52-640 supports one LEM-320; the NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s. The LEM-320 module is used to expand the NFS-640/NFS2-640 to a second loop, and to expand each LCM-320 used on the NFS-3030/NFS2-3030 - each NFS-3030/NFS2-3030 LCM-320 supports an expansion LEM-320. Features Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop (twisted-unshielded). Built-in degraded mode increases survivability. Very simple installation - plug-in style. Permits multiple loops in small enclosure. Specifications Loop Control Loop Expander Voltage: 24 VDC nominal, 27.6 VDC maximum. Module Module Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2) twisted-pair wire is 12,500 feet (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2) to 18 AWG (0.78 mm2): - Distance with 12 AWG: 12,500 ft (3,810 m). - Distance with 14 AWG: 8,000 ft (2,438 m}. - Distance with 16 AWG: 4,875 ft (1,486 m). - Distance with 18 AWG: 3,225 ft (983 m). —50 ohms maximum per length of Style 6 & 7 loops. —50 ohms maximum per branch for Style 4 loop. Maximum current: for LCM-320: 130 mA; for LEM-320: 100 mA; for single SLC loop: 400 mA maximum. NOTE: Maximum short circuit - loop will shutdown until short-cir- cuit condition is corrected. Maximum resistance: 50 ohms (supervised and power- limited). Temperature and humidity ranges: This system meets NFPA requirements for operation at 0— 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. Product Line Information LCM-320: Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s. LEM-320: Loop Expander Module. Expands each LCM used on the NFS-3030/NFS2-3030; expands NFS-640/NFS2-640 to two loops. Agency Listings and Approvals The listings and approvals below apply to the basic LCM-320 and LEM-320. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL: S635 ULC:5635/CS11B FM Approved CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 with NFS-3030/NFS2-3030). 7165-0028:214, 7170- 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- 0028:244 (LEM-320 with NFS2-640). FDNY: COA#6025 (LEM-320 with NFS2-640) FDNY: COA#6026 (LCM-320/LEM-320 with NFS2-3030) City of Denver Hong Kong DN-6881 Al • 06/05/2009 - Page 1 of 2 S S VOLTAGES Agency Listings and Approvals These listings and approvals apply to the AMPS-24/E power supply. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S635 ULC:C5118 City of Chicago City of Denver MEA: 345-02-E CSFM: 7165-0028:224 FM: Approved FDNY: #6026 Product Line Information AMPS-24: Addressable power supply/battery charger AMPS-24E: Same as AMPS-24: 220-24OVAC operation DN-6883:B AMPS-24/E Power Supply (Q NOTIFIER® for the NFS.3030, NFS2-3030 and NCA-2 by Honeywell CatalogSectioni General S NOTIFIER's AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs. It operates in either FlashScan® or CLIP (Classic Loop Interface Protocol) mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel (FACP). It can also be used as the primary power supply for the NCA-2 Network Control Annunciator. Features Addressable by NFS-3030/NFS2-3030 FACP. Selectable charging current charges 7 AH to 200 AH batter- ies. Isolated Signaling Line Circuit (SLC) interface. Trouble bus input for use with normally-open dry contacts or open-collector circuit. USB Type B connector for programming installation param- eters. Brownout detection. Battery/battery charger supervision. Secondary Power Auxiliary Outputs: 24V @ 0.5A and 5V @ 0.15A. AC loss detection and AC loss delay reporting. Mounts in a CAB-4 Series enclosure, EQ Cabinet Series enclosure, BB-25, BB-100, or BB-200 Battery Backbox. Specifications Primary (AC) power: AMPS24: 110-120 VAC 50/60 Hz input, 5 A maximum; AMPS24E: 220-240 VAC 50/60 Hz input, 2.5 A maximum. MAIN 24V Output - filtered power-limited power. Refer to table for configuration/current information. Charger Setting! Main 24V (TB 1 on *Total AUX 24V (T133 on Main Battery Size Main Control Unit) Control Unit with T132 on CPS- Max. Current 24) Max. Current 1A!7-26AH Bat- 5A 3A tenes 2AJ1260Al1 Bat- Bat- 5A 3A teries 5N55-200AH Configuration 1 5A BA Configuration 2 3A 1A Disabled 5A 5A * Maximum current for all AUX 24 volt outputs. Note that TB2 on CPS-24 is limited to 0.5A. AUX 24V - provides filtered power-limited power for addi- tional components. Refer to table above for configuration/ current information. Secondary power (battery) charging circuit: Current-limited, sealed lead-acid battery charger which will charge 7 to 200 AH batteries. Selectable charging current: 1.0 A, 2.0 A or 5.0 A. Secondary power auxiliary outputs. Wire sizes: 10 AWG (5.26 mm2) to 22 AWG (0.326 mm2). Battery fuse (F2): 15 A, fast-acting. Shipping Weight: 4.25 lb S DN-6883:B • 10/15/09 - Page 1 of 2 DN-60565:A DS-DB Digital Series Distribution Board S Voice Control Systems The DS-DB Digital Series Distribution Board and its associ- ated amplifiers provide bulk amplification capability to the Digi- tal Voice Command (DVC) system while retaining digital audio distribution capabilities. Up to four DS-AMP/E amplifiers can supply high-level risers spread throughout an installation. The DS-DB converts digital audio to analog and routes it to audio amplifiers and optional backups. The amplifiers send back high-level audio, which the DS-DB routes to its risers. Control and status information passes between the DS-DB and its components via EIA-485 bus. The DS-DB communi- cates with the rest of the digital audio system through the DAL (digital audio loop), and takes up two of the 32 DAL addresses. It may be mixed with other devices on the same DAL, such as the DAA2 and DAX series amplifiers. An optional Firefighters' telephone riser on the DS-DB sup- ports local and network FFT communications. Features Input capacity of four digital audio channels. Four DVC-AO-level audio outputs for connection to amplifi- ers in the same cabinet. Eight high-level audio inputs (four primary, four backup), each input capable of handling 125W of audio at 25VRMS or 100W at 70.7VRMS. Four Class Neight Class B high-level 125W audio outputs, each of which can output all 125 watts from any one of the four high level primary inputs or four high-level backup inputs. Two digital audio loop wire ports, which may be modified to single- or multi-mode fiber ports with fiber option modules. USB port for VeriFire Tools® communication. Local FFT riser, capable of acting as a connection on the digital FFT riser. DS BUS interface to communicate with local bulk amplifiers and power supplies. Up to 106 seconds of standard quality backup digital mes- sage storage (from Veri Fire Tools® message library, or cre- ated by the installer) for use in the event of communication loss with the DVC. Isolated alarm bus input, to be used for backup activation of alarm messages when normal communication with the DVC is lost. Audio output activation via network control-by-event equa- tions resident within the DVC. Uploads and downloads via the DVC. 24 VDC input for local power. Works with AMPS-24 power supply and battery charger. Installation The DS-DB arrives from the factory already installed on its chassis. The DS-DB mounts in a CAB-4 Series cabinet, as well as in an EQCAB Series backbox. One or two fiber option modules will plug directly onto a DS- DB for simple installation. A DS-BDA backup amplifier mounts directly onto a DS-DB. Specifications 24 VDC Input (TB24): 0.6A alarm or standby, non-resettable. Power-limited by source, supervised. Any device connected to TB24 must be installed in the same enclosure, or within the same room in conduit. Digital Audio Ports, wire media, A and B: EIA-485 protocol, power-limited. Maximum distance per segment is 1900 feet (579.12m) on Belden 5320UJ (18AWG, TP) FPL cable: 18AWG (0.821 mm2) twisted-pair, unshielded, power-limited. For approved cable types, see wiring documentation, PN 52916ADD, Approved Wire Cables for Digital Audio Loops. Digital Audio Ports, fiber media, fiber option modules: Dig- ital audio loop connectors support single- and multi-mode fiber with the use of fiber option modules. Refer to the fiber option datasheet for fiber specifications. Alarm Bus: Power-limited, supervised by source. Recom- mended wiring: 14-18 AWG twisted-pair. Requires 16VDC minimum @ 20mA across the terminals to activate. Nominal 24VDC. FFT Riser: Power-limited output, supervised. Class A or Class B operation. Class B 2-wire connections require a 3/9k ohm 1/ 2 watt resistor (PN R-3.9K). Max. wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 ft (3048 m) max. wiring distance at 14 AWG to last handset. DS-BUS: ElA-485 protocol, power-limited. DS-BUS points must be installed in the same enclosure or within the same room in conduit. End points require end-of-line resistors. DS-DB endpoint: set termination switch (SW8)to ON. DS-AMP endpoint: add 120 ohm resistor on empty T131 ter- minals. AMPS-24 endpoint: resistor is present, and power supply must be an endpoint. Use 14-18 AWG, twisted unshielded wire. Audio Out: Power-limited outputs (exception: an output pro- grammed for "Riser Mode to Control Modules", "Riser Mode to RSM-AIM Series Modules", or "Riser Mode to CIM/CSM Series Modules" is non-power-limited.)Up to 125 Watts output. S S DN-60565:A.O1/16/2012—Page 1 of 2 DS-FM: Fiber option module for multi-mode fiber. Converts a wire DAP (digital audio port) to a multi-mode fiber port. See DN-60633. DS-SFM: Fiber option module for single-mode fiber. Converts a wire DAP (digital audio port) to a single-mode fiber port. See DN-60633. DS-RFTvI: Fiber option module for multi-mode fiber. Used exclusively for compatibility with multi-mode fiber DVC or DAA. See DN-60633. Supervision determined by programming. 25VRMS or 70VRMS, S depending on amplifier setting. Class A or Class B operation. Class B requires 20k end-of-line resistors (included, PN ELR- 20K). Class A required 10k end-of-line resistors (included, PN R-10K) on the return. 12-18 AWG twisted-pair (shielded rec- ommended). Primary and Backup 1 thru 4: Four DVC-AO-level audio out- puts for connection to amplifiers. Non-power-limited inputs. Supervision programmable. Amplifiers must be installed in the same enclousre or within the same room in conduit. Recom- mended wiring: 14-18 AWG, twisted-pair, unshielded. OUT: Four DVC-AO-level audio outputs for connection to amplifiers. Power-limited. Supervision programmable. Amplifi- ers must be installed in the same enclosure or within the same room in conduit. 14-18 AWG, twisted-pair, unshielded. Standards and Codes The DS-DB Digital Series Distribution Board complies with the following standards: NFPA 72 2007 National Fire Alarm Code Underwriter Laboratories Standard UL 864 Underwriter Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems Part 15 Class A conducted and radiated emissions as required by the FCC. Listings and Approvals These listings and approvals apply to the DS-DB Digital Distri- bution Board. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult S factory for latest listing status. UL Listed: S635 ULC Listed: S635 CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). Product Line Information DS-DB: Digital Series Distribution Board. DS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMs), 100W (70VRMS). Ships with chassis. See DN- 60663. DS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMS). 70VRMS configuration requires step-up transformer. Ships with chassis. See DN- 60663. DS-BDA: Backup amplifier, provides an economical means of backup for DS-AMP amplifiers in a one-to-one primary/backup configuration. Can also provide a second audio channel for a DS-AMP when programmed as a primary amplfier. 25VRMS or 70VRMS. 70VRMS configuration requires step-up transformer. See DN-60663. DS-XF70V: Step-up transformer, required for 70VRMS config- uration of DS-AMP/E and DS-BDA. Ordered separately. See DN-60663. NOTIFIER® and yen-Fire® are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I S Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I I ________________ I All specifications are subject to change without notice. SUILITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60565:A • 01/16/2012 DN-60663:A DS-AMP Digital Series Amplifier for use with the DS-D13 Distribution Board General As part of a DS-DB Digital Series system, the DS-AMP Digital Series amplifier provides bulk amplification to a Digital Voice Command (IYVC) system. Up to four DS-AMP amplifiers can be connected to one DS-DB to supply high-level audio. Backup audio circuits are available by adding DS-BDA or dedi- cated DS-AMPs. Features 125 watts of audio power at 2SVRMS. 100 watts of audio power at 70VRMS. This option requires step-up transformer DS-XF70V, ordered separately. Compatible with a DS-BDA that is being used as a backup or second audio channel. (A DS-BDA used as a backup or second channel for a DS-AMP configured for 70VRMS requires step-up transformer DS-XF70V, ordered sepa- rately.) EIA-485 communication with DS-DB. Installation The DS-AMP arrives from the factory already installed on its chassis. It mounts in one row of any EQ or CAB-4 Series cabi- net. The CAB-4 row can be covered using a DP-1B dress panel, ordered separately. A step-up transformer (ordered sep- arately) easily mounts on the front of the DS-AMP for 70VRMS configurations. Specifications AC Power, T134: 120 VAC 50/60Hz input; 4.1 A maximum when used for 25V (125W). 3.55 A maximum when used for 70V(100W). Eversion: 220-240 VAC 50/60 Hz input; 2.4 A maximum when used for 25V (125W). 2.1 A maximum when used for 70V (bOW). Recommended wiring: 12-14 AWG (1.6 mm O.D.) with 600 VAC insulation. Battery Connections: Supplied cable connections to batter- ies. For battery sharing, use 12 AWG either in the same cabinet or in conduit for no more than 20 feet (6.09 meters). High Level output (TB3): Non-power-limited, supervision pro- vided by DS-DB. Recommended wiring: 14-18 AWG, twisted- pair, unshielded. Audio In (TB2): Power-limited, supervision provided by DS- DB. Recommended wiring: 14-18 AWG, twisted-pair, unshielded. NOTIFIER® by Honeywell Standards and Codes The DS-AMP amplifiers comply with the following standards: NFPA 72 2007 National Fire Alarm Code. Underwriter Laboratories Standard UL 864. Underwriter Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems. Part 15 Class A conducted and radiated emissions as required by the FCC. Listings and Approvals These listings and approvals apply to the DS-AMP amplfiers. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: 5635. ULC Listed: 5635. CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). Product Line Information OS-AMP AMPLIFIERS Shipped mounted to the chassis. DS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMS). DS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMS). 70VRMS configuration requires step-up transformer. DS-BDA AMPLIFIER Backup amplifier, provides an economical means of backup up DS-AMP amplifiers in a one-to-one primary/backup configura- tion. Can also provide a second audio channel for a DS-AMP when programmed as a primary ampifier. DS-BDA: 25VRMS or 70VRMS. 70VRMS configuration requires step-up transformer. STEP-UP TRANSFORMER DS-XF70V: Transformer required for 70VRMS configuration of DS-AMP/E and DS-BDA. Ordered separately. Q S DN-60663:A.O1/16/2012—Pagel of 2 DN-7045:1 • C-7 DVC Series NOTIFIER® Digital Voice Command DVC-EM by Honeywell VoiceT7 t-(I General S The DVC is the heart of an integrated, full-featured Audio Command Center. The DVC Digital Voice Command combines the capabilities of a powerful digital audio processor, an event- driven audio message generator, and a router. Designed for use with Digital Audio Loop (DAL) devices such as DAA2, DAX and DAA series digital amplifiers as well as the DS-DB, each DVC supports a dedicated audio network with up to eight channels of audio, five channels of firefighter telephone com- munications, and control and supervision for up to 32 DAL devices. The DVC has two wire digital audio ports to connect to wire DAL segments. Either or both ports may be converted to multi-mode fiber or single-mode fiber using fiber option modules. Larger audio systems incorporating hundreds of amplifiers can be created by networking adoitional DVC units via NOTI•FIRE•NET'. The DVC may be networked with ONYX® Series panels via NOTI•FIRE•NET with an NCA-2, or with an NFS2-3030 (running in network monitor mode). A DVC can be connected directly with a single NFS2-640 or NFS2-3030 Fire Alarm Con- trol Panel (FACP) to create a standalone integrated audio solu- tion as well. Refer to the DVC manual for details. When used as an Audio Command Center with Emergency Paging capability, the optional DVC-KD Keypad Display is required. NOTE: Unless otherwise noted, the term "DVC" refers to the DVC- EM. Features Programmable from NUP port using VeriFire Tools. Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created mes- sages and tones. Supports twisted-pair wire media. Sup- ports single- and multi-mode fiber-optic media when used with fiber option modules. 4-channel analog audio supported with optional DVC-AO Up to 1000 audio sequences. Message prioritization. Equations support flexible programming for distribution of messages. Electrically isolated digital audio ports for direct connection with up to 32 Digital Audio Loop (DAL) devices. Style 4 or 7 configurations supported. Optional DS-RFM, DS-FM, and DS-SFM fiber modules may be used to convert one or both Digital Audio Ports for oper- ation with single-mode or multi-mode fiber. DCC (Display and Control Center) capabilities when used with optional DVC-KD. Firefighters' Telephone Communications to local FFT riser on DVC, 32 local DAL device FFT risers, and FFT communication to additional command stations via NOTI• FIRE. NET. Local paging microphone option. Remote microphone options. Optional Digital Voice Command Remote Paging Unit (DVC-RPU), or DVC-RPU mode. DVC Shown using CA-2 mounting option, SBB-C4, and ADDR-C4 door. Broad All-Call functionality when used with DVC-KD (DVC- Keyboard Display): All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas. Auxiliary input for 12 Vp-p analog low-level audio sources. Includes user audio level adjustment feature. Auxiliary input accepts external audio sources such as tele- phone paging or background music. High impedance input accepts 600 ohm, line level, 1.0 VRMS, or 1.41 Vp-p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported. Associated NCA-2, or NFS2-3030 (programmed for net- work monitor mode) supports NOTI•FIRE•NET applica- tions. Multiple audio command centers supported via NOTI • FIRE • NET. Distribution of one channel of standard-level paging audio on NOTI•FIRE•NET. Three standalone, non-network mode options: - NFS2-3030 (NUP to NUP) digital and analog. - NFS2-640 (NUP to NUP) analog audio only. - NFS2-640 with NCA-2 (NUP to NUP to NUP) digital and analog. Push-to-talk relay, or logic argument. Isolated alarm bus input, to be used for backup activation of alarm messages in the event network communication is lost. Installation Options The DVC provides flexible configurations based on one-row or two-row chassis options that mount into size "B", "C", or "D" CAB-4 Series cabinets. I DN-7045:I • 12/20/2013—Page 1 of 4 S I The CA-2 supports a DVC, paging microphone, optional FFT telephone, and mounting location for an NCA-2 or NFS2- 3030D CPU. The ADDR audio door series can be used when a CA-2 is mounted in the top two rows. The CA-1 supports a DVC and an optional microphone in a single row. For firefight- ers' telephone applications with a CA-1, the CFFT-i can be mounted in the row below the CA-1. NOTE: For NFS2-640/DVC applications using DAL devices, an NCA-2 is required to annunciate DAL device events. Refer to the DVC System Audio Product Application Guide (part number M-AG-DVC) for more details on DVC applica- tions). Specifications 24 VDC power (TB1): 24 VDC, 1.0 A, non-resettable, power-limited by the source. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Digital audio ports, wire media, A and B (TB2, T133): Maximum distance per segment is 1900 feet (579.12 m) on Belden 5320UJ (18 AWG, TP) FPL cable: 18 AWG (0.821 mm2) twisted-pair, foil-shielded, power-limited. Consult wir- ing documentation provided in document P/N 5291 6ADD:C Addendum to DVC and DAA Manuals. Digital audio ports, single- and multi-mode fiber-optic media: (See notes below) - DS-FM and DS-SFM fiber option module (no direct DAA connection): 6.5dB maximum attenuation for multi-mode with 50/125 micrometer cable @ 1310 nm. 10dB maximum attenuation for multi-mode with 62.5/ 125 micrometer cable @ 1310 nm. 30dB maximum attenuation for single-mode with 9/125 micrometer cable @ 1310 nm. - DS-SFM (single-mode fiber DAA connection): 17dB maximum attenuation for single-mode with 9/125 micrometer cable at 1310 nm going from the DS-SFM to the fiber DAA. 4dB maximum attenuation for single-mode with 9/125 micrometer cable going from the fiber DAA to the DS- SFM. 12dB minimum attenuation going from the DS-SFM to the fiber DAA. - DS-RFM (multi-mode fiber DAA connection): Attenuation going from the fiber DAA to the DS-RFM: 2dB maximum attenuation for multi-mode with 50/125 micrometer cable @ 850 nm for the DS-RFM. 4dB maximum attenuation for multi-mode with 62/5/125 micrometer cable @ 850 nm for the DS-RFM. Attenuation going from the fiber DS-RFM to the fiber DAA: 12dB minimum attenuation, 16dB for both cable types. Notes: If the length of the fiber run results in an attenuation of less than 12dB, a suitable attenuator must be used. ST® Style connection required at DAA end of any fiber connection. LC style connectors are required for the DS- FM, DS-RFM, and DS-SFM. Auxiliary input A (AUX A, TB4): Signal strength from low- level analog audio input: maximum 1.0 VRMS, or 1.41 Vp-p. Optional supervision is selectable through programming. Recommended wiring: 18 AWG (0.821 mm2) twisted-pair; max. 14 AWG (2.08 mm2). Auxiliary input must be in the same room as the DVC. Auxiliary input B (AUX B, T814): Signal strength from low-level analog audio input: 12 Vp-p nominal, 15 Vp-p maxi- mum. Optional supervision is selected through program- ming. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Remote microphone interface (TB9): Recommended wir- ing: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Power- limited. Maximum distance between remote microphone and DVC: 1000 feet (300 m). Push-to-talk interface (T1310): Dry contact. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted- pair. Alarm bus (TB12): Power-limited by source. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted- pair. FFT riser (TB13): Power-limited output. Class A (Style Z) or Class B (Style Y) operation. Style V two-wire connections require a 3.9K ohm, 1/2 watt resistor (P/N K-3.9K). Maxi- mum wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 feet (3048 m) maximum wiring distance at 12 AWG (3.31 mm2) to last handset. Optional DVC-AO analog audio output circuits (TB5, TB6, TB7, and T88): Supervised, power-limited outputs. Signal strength: +12 Vp-p nominal, +15 Vp-p maximum. Rec- ommended wiring: 18 AWG (0.821 mm2) twisted-pair; max. 14 AWG (2.08 mm2). Maximum impedance: 66 ohms. Standards and Codes The Digital Voice Command DVC and DVC-EM comply with the following standards: NFPA 72 2002 National Fire Alarm Code. Underwriters Laboratories Standards UL 864, 9th edition, and UL 2572. Underwriters Laboratories of Canada (ULC) ULC-5527-99 Standard of Control Units for Fire Alarm Systems. Listings and Approvals The listings and approvals below apply to the DVC and DVC- EM Digital Voice Command. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. FM Approved. CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#61 14 (NFS2-3030): COA#6085, COA#6121 (NFS2-640). City of Chicago approved: High Rise, Class 1, Class 2 (NFS2-3030, NFS2-640, NCA-2). City of Denver approved (NFS2-3030). PSB Corporation approved (Singapore) (NFS2-3030). Product Line Information DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. Supports twisted-pair wire media. Options: DS Fiber modules, DVC-RPU. DVC-RPU: Digital Voice Command Remote Paging Unit. Includes the keypad/display. Supports twisted-pair wire media; use DS fiber modules for fiber media. See DN-60726. DVC-KD: Keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. Page 2 of 4— DN-7045:I • 12/20/2013 DVC-AO: Optional DVC Analog Output board provides four analog output circuits for use with AA or XPIQ Series amplifi- ers. Four-channel operation supported. CA-11: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC and a DVC-KD (optional); and the right side houses a CMIC-i microphone and its well (optional). CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. CFFT-1: The CFFT-1 Chassis for Firefighters' Telephone mounts in the row directly under a DVC that is mounted in a CA-1 single row chassis. The CFFT-1 includes one FFT hand- set. The DP-CFFT Dress Plate (separately ordered, required) has one open position for mounting an ACS annunciator or a BMP-i Blank Module Plate. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes a microphone. DPA-213 dress plate is required (below); the VP-2B Vent Plate is also required for top row configurations. ADDR Series doors with two-tier visibility are available for use with the CA-2 configura- tion: ADDR-B4, ADDR-C4, ADDR-D4 (below). DPA-2113: Dress plate required for CA-2 chassis assembly. VP-2B: Vent plate required for cabinet configurations where the DPA-213 is used for the top two row position. TELH-11: Firefighters' Telephone Handset for use with the DVC when mounted in the CA-2 chassis. Order separately. ADDR-1134: Two-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "OR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-6857. ADDR-C4: Three-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "OR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-6857. ADDR-04: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-04 backbox with the ADDR-04. See DN-6857. DPA-1: Dress panel, can be used with the CA-i chassis when configured with a DVC, DVC-KD, and CMIC-1. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-i is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. ACT4: Audio-coupling transformer. Used to electronically iso- late DVC-AO analog risers. ACT-25, ACT-70: Audio-coupling transformers for 25V and 70V high-level audio. Used to isolate and convert high-level audio to low-level, supporting applications with large numbers of analog amplifiers. DAX-3525(E)/DAX-3570(E): 35W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 2 Class B or i Class A output, shipped mounted on chassis. Options: BDA- 25/70 backup amplifier, OS Fiber modules. DAX-5025(E)/DAX-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with power supply and 2 Class B or i Class A output, shipped mounted on chassis. Options: BDA-25170 backup amplifier, DS Fiber modules. DAA2-5025(E)1DAA2-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-i port, FFT port, Aux audio port. Supports optional BDA for backup ampli- fier or 2-channel operation, and DS Fiber modules. DAA2-7525(E): 75W, 25VRMS. Digital audio amplifiers with power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-i port, FFT port, Aux audio port. Supports optional BDA for backup amplifier or 2-channel oper- ation, and DS Fiber modules. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC while retaining digital audio dis- tribuition capabilities. Can be configured with up to four OS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-BDA: Digital Series Backup Digital Amplifier, 25 or 70VRMS, can be configured to act as a one-to-one backup for OS-AMP/E amplifiers. Can also be programmed to provide a second audio channel for a DS-AMP. See DN-60663. BDA-25, BDA-70: Backup Digital Amplifier, 25 or 70.7VRMS, can be configured to act as a one-to-one backup for DAX and DAA2 series amplifiers. For DAA2 Series only, supports alter- native second channel operation. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For DAA-50 series amplifiers, see DN-7046. For DAA-7525 Series, see ON-60257. - DAA-5025: SOW, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted-pair wire media. (For multi- mode fiber-optic media order DAA-5025F For single- mode fiber-optic media order DAA -5025SF) - DAA-5070: SOW, 70.7Vrms Digital Audio Amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted-pair wire media. (For multi-mode fiber-optic media order DM-5070F For single-mode fiber-optic media order DAA-50705F) - DAA-7525: 75W, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board. Shipped mounted to its chassis (no battery charger on DAA-7525 power supply board). Supports twisted-pair wire media. (For multi-mode fiber-optic media order DAA-7525F For sin- gle-mode fiber-optic media order DAA-7525SF) SEISKIT-CAB: Seismic kit for CAB-4 series cabinets. Includes battery bracket for two 26AH Power Sonic batteries and TELH- 1 telephone handset strap. See document 53829. SEISKIT-DAA: Seismic kit for DAA, DAA2 and DAX series amplifiers, required when using CHS-BHi chassis. Includes battery bracket for two 12AH Power Sonic batteries. See docu- ment 53851. C S DN-7045:I • 12/20/2013 - Page 3 W4 DN-60686:A1 (VD.ACT.;) Universal Digital Alarm Communicator Transmitter General The Universal Digital Alarm Communicator Transmitter (UDACT- 2) is designed for use on Notifier Fire Alarm GDntrol Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTI.FIRE.NETTM. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, ard AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Maximum of 14 point trouble messages transmitted per hour. Dual phone lines with line voltage detect. Compact in size: 6.75" x 4.25" (17.145 x 10.795 cm). USB port for upload/download programming. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1 B/R). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. —12 0r24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. NOTIFIER® by Honeywell Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. Real-time clock. Extensive transient protection. ElA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. S S -- DN-60666:Al .4/2/12— Page 1 of 2 C Communication Formats Ademco Contact ID 4+2 Standard SIA NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format - only Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterflow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications (Standby current OmA. urreni whHecomrnunlcatIng:75mA Maximum current while communicating and with open collector output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S635 FM Approved CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (NFS2-3030) FDNY: COA#6085, COA#6098 Ordering Information UpCT-2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mounting hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-BRB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94" H x 4.63" W x 2.50" D (cm: 25.248 H x 11.760W x 6.350 D). UBS-1 B: Metal enclosure with solid door, Black. UBS-1 BR: Metal enclosure with solid door, Red. R-1 OE: SPOT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A © 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit Use for remote mounting only. UL Listed Receivers The chart below shows UL listed receivers compatible with the UDACT-2. A check in the protocol column indicates the receiver supports that protocol. Receiver 4+2 Standard 180012300 Ademco Contact ID SIA Ademco 685 (1) Ademco MX8000 (2) Silent Knight 9500 (3) Silent Knight 9800 (4) FBI CP220FB (5) Osborne Hoffman 2000E (6) Radionics 6600 (7) SurGard MLR2 (8) p.' SurGard System III (9) v SurGard MLR-2000 (10) With 685-8 Line Card with Rev 4.4d software With 124060V206B and 124063 Line Card Rev B With version V2.4 Receiver & 126047 Line Card Rev G With 124077V2.00 Receiver &126047 Line Card Rev M With software V3.9 With V.7301 Receiver SIW With 01.01.03 Receiver S/W & Line Card 01.01.03 With software V1.86 With sotware V1.72 With D5P4016 and V1.6 Line Card NOTl.FlRE.NET' is a trademark and Notifier® is a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 933033M= _ U We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60686:AI • 4/2/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. i0028: Page 1 of 4 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Model NFS-3030, NFS-3030E,2-) NFS2-3030E fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), automatic, manual, waterflow and sprinkler supervisory services. Suitable for use as a releasing service, Emergency Voice/Alarm Communication System and Process/Energy Management Equipment. Refer to listee's data sheet for detailed product description and operational considerations. System components: AA-30/-100/-120; Amplifiers ACM-8R1-16AT/-24AT1-32N-48A; Annunciator Control Modules ACPS-610; Addressable/Charger Power Supply ACPS-2406; Addressable Charger/Power Supply ACT-1/-2/-4/-25/-70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4RI-D4/-D4R; Doors AEM-1 6AT/-24AT/-32A/-48A; Annunciator Expander Modules AFM-1 6N-16ATI-32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch AMG-1/-E; Audio Message Generator AMPS-24, CPS-24; Addressable Main Power Supply APS-6R, APS2-6R; Auxiliary Power Supply ARM-4; Auxiliary Relay Module BDA-25V1-70V; Backup Digital Audio Amplifiers BGRA-SCS, BGRB-SCS, CEF-SCS, RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station BB-17/-25/-100/-200; Battery Box BMP-1; Blank Module BP-4; Battery Panel BP2-4; Dress Panel CA-1/-2; Chassis CAB-3/4 Series, EQ Series; Enclosures *CABRP CAB-RPR; Cabinets CHG-120; Battery Charger CHS-4U-4MB/-4N/-6/-M3/-PS/-BI11; Chassis CMIC-1, CMICRP*; Microphone Assembly CPU2-3030D/CPU2-3030ND; CPU Board *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct * operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S Listing No. 7165-0028:0224 Page 2 of 4 . CRE-4; Control Relay Expander CRM-4RK; Control Relay Module CRT-2; Display Terminal DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers, Fiber Mode DAA-5070F/DAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF Series; Digital Audio Amplifiers DAA-PS; Power Supply DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DCM-4RK; Dual Channel Module DP-1 B; Blank Panel DP-DISP; Display Dress Panel DR-A4, DR-A4B, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA413, DR-AA4BR, DR-AA4R; Door Assembly DR-133F; Door Assembly DR-134, DR-13413, DR-13413R, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DPDW-IB, DPSW-IB, XPDP; Dress Panels VP-213, DPA-1/-1A4/-2; Dress Panels DPI-232; Direct Panel Interface DVC-AO; Digital Voice Command • DVC-EM; Extended Memory DVC-EMF/DVC-EMSF; Digital Voice Command/Ext Memory DVC-KD; Keypad Board *DvCRPU; Remote Paging Unit EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1-REL; Releasing Control Module FCPS-24S6/58; Field Charger/Power Supply FFT-7/-75; Fire Fighter's Telephones FIRSTVISION-LCD; Interactive Firefighters' Display FIRSTVISION-ENC; FirstVision Backbox Enclosure and Door FMM-4-20; Analog Input Module FHS; Fireman's Handset FCM-1; Addressable control module FDM-1; Dual monitor module FDRM1*; Dual Relay/Monitor Module FMM-1; Monitor module FMM-101; Miniature monitor module *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 3 of 4 FRM-1; Addressable relay module FTM-1; Firephone Control Module FPJ; Fireman's Phone Jack FZM-1; Two-wire detector monitor module HS-NCM-W/-MF/SF/-WMF/-WSF/-MFSF; High Speed Network Control Modules ICE-4; Indicating Control Expander ICM-4RK; Indicating Circuit Module IPDACT-2/-2UD/l PENC; I P Digital Alarm Communicator ISO-X; Isolator Module IZE-A; Initiating Zone Expander IZM-8RK; Initiating Zone Module LCD-80, -160; Liquid Crystal Display Module LCD2-80; Liquid Crystal Display ptrIe) LDM-32/-E32/-R32; Lamp Driver Module EM-320; Loop Expander ModuIe) MP-IB; Blank Panel MPS-2413; Power Supply Module NBG-12; Series Addressable Manual Pull Station NBG-I2LX; Manual pull station, addressable. See DN-6726 NCA/NCA-2; Network Control Annunciator NCM-W/-F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station, Wire/Fiber NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station, Wire/Fiber ONYXWorks-EW/-NW/NF/-HNW/-HNMF/-HNSF/-TS/-EW-T5/-NF-T5/-HW-TS/HNMFT/ -HNSFT/- HNWT; Graphics PC workstation for NOTI-FIRE-NET Wire/Fiber/with Touch-screen monitors N-ELR; End of Line Resistors NFS-LBB/-LBBR; Battery Box PRN-6; Printer R-120/-2.2K/-27K/-470/-47K; End of Line Resistors RA-400/-400Z; Remote Annunciators RKS-S; Remote Security Keyswitch RM-1/-ISA; Remote Microphone RPJ-1; Remote Paging Jack RPT-W/-F/-485W/-485WF; Repeater SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-M4R; Backbox Assembly SBB-B4, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly SCS-8; Smoke Control Station SCS-BL; Smoke Control Lamp Driver Station SCE-8; Smoke Control Expander SCE-8L; Smoke Control Expander Lamp STS-1; Security Tamper Switch *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S Listing No. 7165-0028:0224 Page 4 of 4 . TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-2561BB--UZC; Universal Zone Coder/Backbox VCE-4; Voice Control Expander VCM-4RK; Voice Control Module VS4095/5; Keltron Remote Printer XP5-C/-M; Transponder XPC-8; Transponder Control Module XPIQ; Transponder Quad Intelligent Audio Module XPM-8/-8L; Transponder Monitor Modules XPP-1; Transponder Processor XPR-8; Transponder Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units suitable for high rise applications for use with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined with Listing No. 7170-0028:223 *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division t COMMERCIAL FIRE PRODUCT FEATURES j Certified for use on the AT&T LIE network for long, sunset- free installation. I Meets UL 864 requirements for sole, primary or backup path communications. I Minimizes false alarms by providing dual paths for self-tests. P Falls back to 3G/4G if an LIE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new sixty minute supervision mode. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. 10175-3 dIG'ItU NOSE fPjce Igu d &T LT e '5KC - efp a elg a d nits. eg ards Gation Gente I du pita poes s a 0S con ec I I beten t OWE 11ar1m el t e eI a i of od c-ts a d he cen tal st tiorj, eUZIechnlcal Sport provId single 0 of contact for bo h ce ar se I _1111 q e..stLQn.. a eaIajas 'to atl sjrt. with ce tThl tIo te 111111 111 relay o tUt for iIn aIa4 I Pan 1jeA t...ouI5I co.nçf on qc-cujs. TELGUARD e tUtforwarP eb nerfac lo s sec n dea er ce ra stat o quic I n ef cie acces eguar ased ser ices 4 7. hi ce 001 as er 0 zation a d jjovides tota ac.co nt na' e tof s ed eg ard lu ar larjt C0TJUfliCa_tps. TG=7FS LTE-A P/NTG7LAF01 CELLULAR ALARM• COMMUNICATOR FOR LTE NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telguard.com. TG=7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD Telguard, a Division of Telular corporation• 3225 Cumberland Blvd SE - Suite 300 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com copyright ©2017 Telular corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-14020109) Page 1 of 1 CATEGORY: 7300 -FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LAA01, *TG7LA001, FG7LAöI1 and *TGKITLAI digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models **TG7(fiAO1 *TG7LA001 are household application. Model *TG7LAF01 and *TGKITLA1 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 01-04-2017 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should rot be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 91 TG-7FS LTE-V CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUAR D P/N: TG7LVFO1 COMMERCIAL FIRE PRODUCT FEATURES I- Certified for use on Verizon's LIE network for long, sunset-free installation. I- Meets UL 864 requirements for sole, primary or backup path communications. I Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LIE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LIE-V can serve as the sole communications path for the fire alarm system. It replaces all of the lancllines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each lanclline replaced with a TG-7FS LIE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7F5 LIE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. -- TG-7Fs CELLULAR ALARM() COMMUNICATOR LTE-V FOR LTE NETWORKS TE LG UAR D ower 6O7mA (Standby) 25OmA (Transmission). I oval 12VAC. 800mA UL listed plug-in. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. For the most current p oduct specifications and UL Listings visit wvrvi.lelguar d.com. SIGNALING SECURITY ® c! L'EJ MIC NFPA 'Ill' E ecuive S. a..g LISTED INTERNATIONAL Cold UL Listings Commercial Fire 864 control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • central station burglar alarm units; Line security servcies Residential 985 Household fire warning systems 1023 • Household burglar alarm systems verlzpj, NETWORK CERTIFIED( Telguard, a Division of Telular corporation • 3225 Cumberland Blvd SE • Suite 300 Atlanta, GA 30339 • USA 800-229-2326, Option 5 wwwTelcjuard.com • copyright c2017 Telular corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING NoT 0-1402:01iö) Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LVO01 *TG7LVA01 ftG7lVF1'and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. AW *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information RD ACE-1 1 SYSTEM RECORD DOCUMENTS Theö)is the perfect item to help-you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 722013 7.2.1). 01 Space Age Made.S.A. REGISTER ED NFPA COMPANY // 800.486.1723 Toll Free isa!om'I 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 E00584 LT 10641 Rev.A 1/2 No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system informatn. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a sta'Pdard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector - ................. ... --.-'-,,.- P,opo,ty Inf,,modon Mini,.,,,, R.q,,h.d DoALn,.ntntlon (SIG-FUN) R.k,.ANFAL722OAS72.,) Certillcntionn and App,ov.I. mA 16.1 Syntan. Installation Contractor. a. ,dthSI NFn.,,th,SM,..,. 4S,.saIjI!n,.&a&. aAIIAASW! C- 16.5 AALthoflty Having J,,H,di,50n: ==_ C C C4fl C SAL.d ID CCC DI C,HDIAL .CCCC. CCISD DC 1.02 EqDAIpm.nt intonnanon IDA(CALCC.CC. ..P 8çDCaQDEALbADC.Im SDOCCDCRCd SCDICCAOICD CCADSIDC LT10644 Re,.I Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. S www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Ordering Information: Part # Description SSU00689 System Record Documents Cabinet RED SSU00690 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! E00584 LT1 0641 Rev.A 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. C7.290553öTT') Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCXJA 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFXIA and IFXID enclosures. ModelsCE-1) ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 30, 20181 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division C TheBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScan® systems, 1 —99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or S DN-6726:D • H-240 ©NOTIFIER® by Honeywell Addressable Manual Pull Station General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, 0r4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.159) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. > ® amum SLC standby current: 375.p > (Maximum SLC alarm current: 5 jjA . • Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location DN-6726:D.4/1312012—Page 1 of 2 4° (10. 16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information (NBG-12LX: Diction addressable pull tation. Includes key, (locking feature. (Listed for Canadian and non-Canadian appil- (ations.)) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. WINEEIIIIIIIII A MNOMIM All specifications are subject to change without notice. SUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-67260 .4/13/2012 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1' LISTING SERVICE LISTING No. (7150-00280199) Page 1 of 1 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO OB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG-121_ BG-1iN G-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-I2LPSP, NBG-125 - NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-I2LWP, NBG-I2LAO, NBG-12L0, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, • SB-I/O, orWP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . JV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6724:B3 FCM.1(A) &CFRM.1(A) NOTIFIERS6 r-- i e s 9 Control and Relay Modules by Honeywell Intelligent / Addressable Devices General S FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. It one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). __ 711,1E,tPWRO flAt* 5LC(lt2 '•"H _I:'fiTiL i2J 12 FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) S DN-6724:B3 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. S External supply voltage (between Terminals T10 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SM8500 Electrical Box; CB500 Barrier CSi_ijisitor FRMi1A) Normal operating voltage: 15 to 32 VDC. (Average operatrng current 230 pA direct poll 255 pA grou poll EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. S Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM..1 (A) Current Maximum Load Application Rating Voltage Desctiption 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (L/R=5ms) 1 A 30 VDC Inductive Coded (UR=2ms) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. (IFAM4(A):ntelhgen dd rbie Re lay ModuieJ A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 93=1=1 U S We cannot cover all specific applications or anticipate all requirements. E10111111111119 A MANOM11111 All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-672433 • 2/17/2011 Made in the U.S. A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 0-002809 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, M-1) FRM-1 control modules, and *FDRM.1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S S CF_M07-I(A), FMM-1 01(A), FZM.i(A) & FDM.1 (A) Monitor Modules with FlashScan® General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75 (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. (1M-1(A) Mpnitor Module) Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class DN-6720:C • H-220 NOTIFIER® by Honeywell FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:C • 10/06/2010 - Page 1 of 4 FMM.101(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01— 99 on CLIP loops. j415 o 1 ADDRESS 0 1 0~ , 1 uq~" ____ 8 76 8 76 i LOOP 1 TENS ONES I—. 0 LU c: lo I: CO LU The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM.101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 493C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75' (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM.1(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/norma Vshort) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 491C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. S S S Page 2 of 4— ON-6720:C • 10/06/2010 FDMI (A) Dual Monitor Module S The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM- 1(A) provides two Style B (Class B) lOG circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125' (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the S FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4' (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMBSOO sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 S . FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: - 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1) - 161.002/42/1 (NFS-640: FMM- 11-101) Lloyd's Register: —03/60011/El (FMM-1I-101, FZM-1) - 94/60004/E2 (AFP-200: except FDM- 1) - 02/60007 (NFS-640: FDM- 1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A' suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-1 01 (A): Monitor module, miniature. M-1 (A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:C • 10/06/2010 - Page 3 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-0028:019 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module,(M-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, RM-1'control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028-.224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division IFDRM.1 (4)) FlashScan®(Dual Relay/Monitor) (Module) General The FDRM-1(A) multi output-input module is designed for use with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). The addressable module is intended for use in intelligent, two- wire loops. It includes two individual relay control modules and two Class B monitor modules. Each relay output is intended for Form C switching applications which do not require wiring supervision for the load circuit. Each monitor input provides an interface between a fire alarm control panel and one or more normally open contact-type devices. Each relay output has its own green LED. Each monitored input has its own bi-color LED, which can be controlled by the control panel. Features Powered by SLC loop directly, no external power required. Mounts in standard junction boxes (4.0/10.16 cm square, 2.125"/5.398 cm deep). Integral LEDs flash green during normal operation (a pro- grammable option) and latch on steady red to indicate alarm. Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels (FACP5). Addressable-analog communication. Sleek, low-profile design. Two-wire SLC connection. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Addresses can be viewed and changed without electronic programmers. Specifications Operating Temperature: 32°F to 120°F (0°C to 490C). Relative Humidity: 10% - 93% non-condensing. Size: 4.675" H x 4.275' W x 1.4' D. (Mounts to a 4" square by 2-1/8' deep box.) Shipping Weight: 6.3 oz. (178.6 grams). ELECTRICAL SPECIFICATIONS Normal Operating Voltage: 15 to 32 VDC. 4axIrnurn Current Draw: 24 mA 4 LEDs on).,) DN-60709:A NOTIFIER® by Honeywell FORM-1(A) Relay Contact Ratings: CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 2A 25 VAC PF = 0.35 Non-coded 3 A 30 VDC Resistive Non-coded 2 A 30 VDC Resistive Coded 0.46 A 30 VDC (hR = 20ms) Non-coded 0.7 A 70.7 VAC PF = 0.35 Non-coded 0.9 A 125 VDC Resistive Non-coded 0.5 A 125 VAC PF = 0.75 Non-coded 0.3 A 125 VAC PF = 0.35 Non-coded Installation and Programming See installation instructions shipped with the module, and the SLC Wiring Manual for complete details. To ensure proper operation, these modules shall be connected to listed compat- ible system control panels only. Mount on a standard junction box (4.0/10.16 cm square) which is at least 2.125/5.398 cm deep. Terminal screws are provided for "in and out" wiring. Installation instructions are provided with each module. Surface-mount box is available as an option. Addressing: - Module base address=Relay Output #1 - Module base address +1 =Monitor Input #1 - Module base address +2=Relay Output #2 - Module base address +3=Monitor Input #2 Each module can use up to four (4) addresses. The base address selected with the rotary address switches will be assigned to relay output #1 from 00 to 156. The module will automatically assign the next three addresses as appropriate to monitored input #1, relay output #2, and monitored input #2. DN-60709:A • 01 /06/2012 -Page 1 of 2 S DIP switch settings can disable relay output #2 or monitored input #2 and free up those addresses. (NOTE: This will affect addressing; see installation manual for details.) NOTE: The inputs and outputs on FDRM-1(A) provide Style B (Class B) circuits ONLY. Style D (Class A) circuits are NOT sup- ported in any application. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S635 CSFM: 7300-0028:0219 Product Line Information NOTE: 'A" suffix indicates ULC Listed model. iayi1onitor MdiTi FDRM-1A: Same as above but with ULC Listing. SM13500: Surface-mount electrical box. DNR(A)/DNRW: Duct detector housing. EA-CB: Control module barrier. 11 NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. . I I We cannot cover all specific applications or anticipate all requirements. BtI1111F3IN All specifications are subject to change without notice. I I IUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60709:A • 01/06/2012 DN-6935:D • H-202 FSP-851 (A) Series Intelligent Plug-In Photoelectric ~*_ I NOTIFIER V Smoke Detectors with FlashScan® by Honeywell Intelligent/Addressable Devic6s- General Notifier FSP-851(A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tors address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detectors unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851T(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851 (A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACP5). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 3600 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1' (5.3 cm) high; base determines diameter. 1P'(lSScm) diarnete 5O1(A4 (10.4 cmdiae - 19200S(A): 6.875(17.46cm) diameter. ii(A) in B2IOLP(A) Base - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2° (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). ULJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. tandby Current (max 300pA @ 24Vbc (one comrn (cation every five seconds with LED enabled).)—_ __-.-------- jnt(rnax )5j iD Installation FSP-851 (A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5° (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring °T-taps" or branches are permitted for Style 4 (Class °B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation S DN-69350 • 12/08/2011 - Page 1 of 2 S sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1 115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-F. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122. BSMl: 01313066760036. CCCF: Certif. # 2004081801000017 (FSP-851 T) Certif. #2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. Fl 1OBP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21 OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851(A) only; box of 10. -* Product Line Information NOTE: "A" suffix indicates ULC Listed model. 851 :Low-profileuitefflgent photoelectric ser mounted to one of the bases listed below.) FSP-851 A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. 851R:Low-iöfile intelligent photoelectric sensor,,, remote test capable. For use with DN RND19J FSP-851 RA: Same as FSP-851 A but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. -> unibis B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 BP: Bulk pack of B501; package contains 10. B2005(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. -Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. (5)2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 93=1=1 111111INE111111111 a 111IMMM1111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:D • 12/08/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7272-0028:0206 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-7511 FAP -851a -751 FSP851R* and FSP-851T photoelectric type smoke detectors. Mod FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S ST.85i(A) Series Intelligent Thermal (Heat) Detectors with FlashScan® DN-6936:13 • 11-211 ©NOTIFIER® by Honeywell General Notifier FST-851 (A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851 (A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 1351'F/571C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851 R/A) in a low-profile package. FST-851 H(A) provides fixed high-temperature detection at 1900171880C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST- 851(A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. CF ST-8511A) in B2IOLP(A) Base 94-5V plastic flammability rating. Remote LED output connection to optional RA100Z(A) remote LED annunciator. Optional sounder, relay, and isolator bases. Optional flanced surface mounting kit. Features • Sleek, low-profile, stylish design. • • State-of-the-art thermistor technology for fast response. • Rate-of-rise model (FST-851R1A), 15°F (8.3°C) per minute. • Factory preset fixed temperature at 135°F (570C); high-tem- perature model fixed at 190°F (880C). • Addressable by device. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Two-wire SLC connection. • Visible LEDs "blink' every time the unit is addressed. • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device-type identifica- tion. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). • • Low standby current. Backward-compatible. • Built-in tamper-resistant feature. • Designed for direct-surface or electrical-box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. S . SEMS screws for wiring of the separate base. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. Specifications Size: 2.1' (5.3 cm) high; base determines diameter. B210LP(A):6°(15cm)amete? E- - B501 (A): 4.1° (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851(A) Series, FST- 851 R(A): —20°C to 38°C (-4°F to 100°F); FST-851 H(A): —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (570C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (880C). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 pA @ 24 VDC (one com) (unicationevery5 seconds with LED enabled)) EDcurrent(maL):5mA@24VDC("ON' Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, zoning, wiring, and special applications. DN-6936:B. 12/07/2011 —Pagel of 2 Installation The FST Series plug-in intelligent thermal detectors use a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. A spe- cial tool allows maintenance personnel to plug in and remove detectors without using a ladder Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747. ULC Listed: S6978. MEA Listed: 383-02-E. FM Approved. CSFM: 7270-0028:0196. BSMI: C1313066760025. CCCF: Certif. #2004081801000018. U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-3200, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Intelligent relay base. Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC induc- tive. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Maximum: 25 devices between isolator bases; see Note 2 under Installation. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B21OLP(A) and B501 (A) bases only. SMB600: Surface mounting kit, flanged. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. Includes 155-127-010. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. S Product Line Information NOTE: "A" suffix indicates ULC Listed model. ----- rFST-851 egnt thermal detector. Must be mounted to one) of the bases hsted beioj FST-851A: Same as FST-851 but with ULC Listing. FST-851 A: Intelligent thermal detector with rate-of-rise fea- ture. FST-851 RA: Same as FST-851 R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851 HA: Same as FST-851 H but with ULC Listing. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. .. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Addressable Intelligent, programmable sounder base capable of producing sound output in high or low volume Notifierr and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - - This document is not intended to be used for installation purposes. I SO 9001 We try tc keep our product information up-to-date and accurate. bd • We cannot cover all specific applications or anticipate all requirements. ENCIREMINS &MRF?ZIUIIJM All soecifications are subject to change without notice. SUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 012— DN-6936:B • 12/07/2011 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 77028:0196) Page 1 of 1 CATEGORY: 7270 - HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kire honeywell.com DESIGN: Model I ') -8)1R, -851H (fixed temperature) and FST-751 R (fixed temperature with Ra - - ise) nic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-751, -751R, -851, and -851R = 135°F fixed temperature Model FST-851H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501, *1321OLP (CSFM Listing No. 7300-1653:0109), or B71OLP base (CSFM Listing No. 7300-0028:173) and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *11222016 dc , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Intell igent Bases NOTI Fl ER® S and Low-Frequency Sounder Bases a by Honeywell rIntelligent/Addressable General - -i Intelligent FlashScan® and CLIP mounting bases and kits provide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selec- tion (see Junction Box Selection Guide). Across this product line, detectors plug in easily to the base with SEMS screws; and models employ various 12 to 24 AWG wire ranges. Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to con- tinue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are avail- able in temporal and non-temporal pattern versions depend- ing on whether the signal is to be used for evacuation purposes. Low frequency sounder bases are UL listed for low frequency operation and comply with NFPA 72 requirements for sleeping spaces. This datasheet discusses the following bases: 13501(A), 13200S(A), B200S-LF, 13200SR(A), 13200SR-LF, 1321OLP(A), B2241B1(A), B224RB(A), 13200SCOA, mounting kits, and accessories. Flangeless Mounting Base B501(A) Flanged Mounting Base tB21OLP() I Relay Base S B224RB(A) B200S(A), B200SR(A), B200SCOA Specifications Diameter: Low-Frequency Sounder Base B200S-LF, B200SR-LF r L B501: 4.1(104mm). B224Bl, B224RB, B21OLP: 6.1(155mm). 13200S, B2005-LF, 13200SR, B200SR-LF, B200SCOA: 6.875 (17.46 cm). Wire gauge: 13224131, B224RB: 14 to 24 AWG. B21OLP, 13501, 13200S, 13200S-LF, B200SR, B200SR-LF, B200SCOA: 12 to 24 AWG Temperature range: 13224B1, B224RB, 13200S, B200S-LF, 13200SR, B200SR- LF, B200SCOA: 32°F to 120°F (0°C to 49°C). B21OLP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 1200F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR B200S, B200S-LF, B200SR, B200SR-LF, B200SCOA: External supply voltage: 16 to 33 VDC (VFWR) Standby current: B200S: 500 pA maximum. B200S-LF, 550 pA maximum. B200SR: 500 pA maximum. B200SR-LF: 1 mA maximum. Alarm current: B200S: 35 mA maximum at high-volume setting; 15 mA maximum at low-volume setting. B200S-LF, High-volume setting: -70 mA maximum © 33.0 VDC. -90 mA maximum © 24.0 VDC. -140 mA maximum @16.0 VDC. 13200S-LF, Low-volume setting: -15 mA maximum © 33.0 VDC. -20 mA maximum © 24.0 VDC. -25 mA maximum © 16.0 VDC. B200SR: 35 mA maximum. B200SR-LF: -65 mA maximum @ 33.0 VDC. S DNJ-60054:I • 2/3/2015 -Page 1 of 4 -90 mA maximum @ 24.0 VDC. S - 125 mA maximum @16.0 VDC. B200SCOA: 40mA Max. (DC), 70mA Max. (FWR) SLC operating voltage: 15 to 32 VDC. S SLC standby current: See applicable sensor specification. Sound output: B200S/B200S-LF, highvolume*: Greater than 85 dBA minimum. B200S/B200S-LF, lowvolume*: Greater than 75 dBA mini- mum. B200SR*/B200SRLF*: Greater than 85 dBA minimum. B200SCOA, highvolume**: Greater than 87 dBA mini- mum. B200SCOA, Iowvolume**: Greater than 85 dBA minimum Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) "Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) FOR 8224R8, B22481: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB only): 20 msec maximum. Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (ULICSA): 0.9 A @ 125 VAC, 0.9A @ 110 VDC, and 3.0A @ 30 VDC. Product Line Information INTELLIGENT BASES B501: Flangeless mounting base. 13501A: Flangeless mounting base, ULC Listed. B501 BP: Bulk pack of B501 (10). B21OLP: Flanged mounting base. B21OLPA: Flanged mounting base, ULCisted B21OLPBP:Bulk pack of B21OLP(10)) B200S: Intelligent addressable sounder base capable of pro- ducing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware. B200SA: ULC-listed version of B200S. B200SCOA: ULC-listed version of B200S with CO detector markings in English/French (required in Canada for ULC applications with FCO-851A). B2005-LF: Low Frequency version of the B200S; produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleep- ing space requirement. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: ULC-listed version of B200SR. B200SR-LF: Low Frequency version of the B200SR; pro- duces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Page 2 of 4— DN-60054:I • 2/3/2015 B224RB: Relay base. B224RBA: Relay base, ULC Listed. B224B1: Isolator base. 6224B1A: Isolator base, ULC Listed. MOUNTING KITS AND ACCESSORIES SMB600: Surface mounting kit, flanged. F1 10: Retrofit flange for converting high-profile bases to low- profile. F11OBP: Bulk pack of Fl 10 (10). F210: Accessory flange ring for B21OLP(A) base (new design). 6-inch diameter. F21OBP: Bulk pack of F210 (10). RA100Z: Remote LED annunciator. RA100ZA: Remote LED annunciator, ULC Listed. M02-04-00: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool for current heads (T55-127-010 included). XR2: Detector Remove Tool for use with low profile detector heads, and FSL-751. XP-4: Extension pole for XR2/B (5 to 15 ft/1.524 to 4.572 m). T55-127-010: Detector removal head. BCK-200B: Black detector kit, package of 10 (for use with photo and ion detectors). WCK-200B: White detector kit, package of 10 (for use with photo and ion detectors). Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S911, S1115. ULC Listed: S911, S1115. FM Approved. MEA: 22-95-E, 205-94-E Vol. 2; 257-06-E CSFM: 7300-1653:0126, 7135-1653:0213, 7300- 1653:0109 Junction Box Selection Guide Base Models Single Gang 3.5" Oct. 4.0" Oct 4.0" Sq. 4.0" Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S, B200S-LF, B200SR, B200SR-LF, Yes Yes Yes Yes Yes No No No No B200SCOA B501 No Yes No No Yes Yes Yes Yes No LB 21q) Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. S S DN-60054:I • 2/3/2015 - Page 3 of 4 S S FlashScan®, NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. UU .1 • We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IVALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-60054:1 • 2/3/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7300-1653:0109J Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.kireyev@honeywell.com DESIGN: Models 401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, 1340413T, 1340 1B501,B 1B,14506587-002,B501BH,B5 B110LP,B110RLP, B11ORLP75O, B1I2LP, 131 141-P, B114LPBT, B1I P and21OLP,d ector bases. Refer to listee's data sheet for detailed product description and op na considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 S 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division dn-60429:al S InnovairFiex Intelligent Non-Relay Photoelectric Duct Smoke Detector General The Notifier lnnovairFlexJintelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelec- tric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme envi- ronments. ifise units sense smoke in the most challenging conditions;) çoperating in airflow speeds of 100 to 4,000 feet per minute, tem- peratures of -4 degrees F to 158 degrees F and ahumidity, (range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sen- sor cover. The Notifier InnovairFIex housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier InnovairFIex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. Features Photoelectric,_integrated low-flow technology • (?P3? /s)) Versatile mounting options: square or rectangular configura- tion Broad ranges for operating temperature (-4F to 158F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Cover tamper signal Increased wiring space with a newly added 3/4" conduit knockout Available space within housing to accommodate mounting of a relay module Easily accessible code wheels on FSP-851 sensor head (sold separately) Clear cover for convenient visual inspection Remote testing capability Requires com line power only Accommodates the installation of an addressable relay mod- ule, sold separately, (FRM-1) for applications requiring a form-C relay NOTIFIER® by Honeywell Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA-4 (DNRW) only Operating Temperature Range: -4 degrees F to 158 degrees F (-20 degrees C to 70 degrees C) Storage Temperature Range: -22 degrees F to 158 degrees F (-30 degrees C to 70 degrees C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) ,Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20 32 m/s5 Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detec- tors, all duct smoke detectors accessories are UL listed. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA400Z OmA 12 mA Max RTS451/ OmA 12mA Max RTS451 KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL Listed: 268A S dn-60429:al • 02/09/09 - Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 1) LISTING No. ç242165300) Page 1 of 1 CATEGORY: 3242 - DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kire ev@honeywell.com DESIGN: Models D ,is1R 0 HS and DNRECL* analog photoelectric duct smoke detector housings. T nits 1st of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-23-10 fn, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Product Line Information . Intelligent non-relay photoelectric low flow smoke detector housing. Requires FSP-851 photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires FSP-851 photoelectric smoke detector (sold separately). FSP-851: Addressable low-profile photoelectric smoke detector DCOIL: Remote test coil required with RTS451/RTS451 KEY DST1: Metal sampling tube duct width up to 1 ft (0.3m) DST1 .5: Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m) DST3: Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m) DST5: Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m) DST10: Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7m) DH4000E-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21 -00: End cap for metal sampling tubes RA400Z: Remote annunciator alarm LED RTS451: Remote test station RTS451 KEY: Remote test station with key lock Important Notes The use of either RTS451 or RTS451 KEY requires the instal- lation of an accessory coil, DCOIL, sold seperately. Please S refer to the DNR or DNRW installation manual for more infor- mation. The RTS451 I RTS451 KEY test coil circuit requires an exter- nal 24VDC power supply which must be UL listed. ONYX® and NOTIFIER® are registered trademarks and NOTI.FIRE.NEF is a trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. S M!%rM_ZTZT3r114 M. We cannot cover all specific applications or anticipate all requirements. 111111INERIN & cu,wc All specifications are subject to change without notice. SUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-60429:al • 02/09/09 Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical beam detection issues such as false alarm incidents and alignment difficulties. Unique Detection Technology The OSID system measures the level of smoke entering beams of light projected over an area of protection. A single OSID Imager can detect up to seven Emitters to provide a wide coverage area. Two innovations in smoke detection technology have been developed for the revolutionary OSID smoke detector: Dual Wavelength Particle Detection The beam projected from each Emitter contains a unique sequence of ultraviolet (UV) and infrared (IR) pulses that are synchronised with the Imager and enable the rejection of any unwanted light sources. By using two wavelengths of light to detect particles, the system is able to distinguish between particle sizes. The shorter UV wavelength interacts strongly with both small and large particles while the longer IR wavelength is affected only by larger particles. Dual wavelength path loss measurements therefore enable the detector to provide repeatable smoke obscuration measurements, while rejecting the presence of dust particles or solid intruding objects. Optical Imaging with a CMOS Imaging Chip An optical imaging array in the OSID Imager provides the detector with a wide viewing angle to locate and track multiple Emitters. Consequently, the system can tolerate a much less precise installation and can compensate for the drift caused by natural shifts in building structures. Optical filtering, high-speed image acquisition and intelligent software algorithms also enable the OSID system to provide new levels of stability and sensitivity with greater immunity to high level lighting variability. Operation Status information (Fire Alarm, Trouble and Power) is communicated through the Imager via Status LEDs, dedicated Trouble and Alarm relays, and the Remote Indicator interface. Specific Trouble (Fault) conditions are identified through coded flashes of the Trouble LED. An internal heating option is also provided on the Imager to prevent condensation on the optical surface, and a reset input enables an external signal to reset the device. Simple Installation and Maintenance The OSID system consists of up to seven Emitters, for the 45° and 90° Imager units, located along the perimeter of the protected area, and an Imager mounted opposite. Each component can be mounted directly to the surface or can be secured with the supplied mounting brackets. Battery powered Emitters with up to five years battery life are also available to reduce installation time and cost. Features Maximum detection range of 150 m (492 ft) for the OSI-lO Status LEDs for Fire, Trouble and Power High false alarm immunity Dust and intrusive solid object rejection Easy alignment with large adjustment and viewing angles No need for precise alignment Tolerant of alignment drift Automatic commisioning in under ten minutes Simple DIP switch configuration Dual wavelength LED-based smoke detection Simple and easy maintenance requirements Conventional alarm interface for straightforward fire system integration Three selectable alarm thresholds Listings/Approvals UL ULC 0 FM AFNOR CE Mark VdS ActivFire BOSEC Major Agency Approvals pending Specifications Supply Voltage 20 to 30 VDC (24 VDC nominal) Imager Current Consumption Nominal (at 24 VDC): 8mA(1 Emitter) lOmA (7 Emitters) Peak (at 24 VDC) during training mode: 31 mA Emitter Current Consumption Wired Version (at 24 VDC): 350pA Std Power, 800pA High Power Battery Version (1.9 - 3.2 VDC): Built-in 5 Year Replaceable Battery Field Wiring Cable Guage 0.2- 4mm2 (26-12AWG) Alarm Threshold Levels: Low - Highest sensitivity I earliest alarm: 20% (0.97 dB) Medium - Medium sensitivity: 35% (1.87 dB) High - Lowest sensitivity / maximum immunity to nuisance smoke conditions: 50% (3.01 dB) Adjustment Angle ±60° (horizontal) ±150 (vertical) Maximum Misalignment Angle ±2° Dimensions (WHD) Emitter! Imager: 208 mm 136 mm 96 mm (8.19 in. x 5.35 in. x 3.78 in.) Operating Conditions* Temperature: -10 ec to 55°C (14 F to 131 0F)° Humidity: 10 to 95% RH (non-condensing) Please consult your Xtralis office for operation outside these parameters. IP Rating IP 44 for Electronics IP 66 for Optics Enclosure Status LEDs Fire Alarm (Red) Trouble I Power (Bi-color Yellow I Green) Event log 10,000 events Approvals Compliance Please refer to the Product Guide for details regarding compliant design, installation and commissioning. Product UL listed for use from 0°C to 39C (32°F to 103°F) On the Imager, a termination card provides all field wiring terminals, and DIP switches enable the user to configure the detector for particular applications. Alignment of the Emitter is simply achieved using a laser alignment tool to rotate the optical spheres until the laser beam projected from the alignment tool is close to the Imager. The Imager is aligned in a similar way so that its Field of View (FOV) encompasses all Emitters. A Trouble or Fault will be indicated if an Emitter is missing or outside the Imager field of view. The OSID system is highly tolerant to dust and dirt and requires little maintenance in practice. Preventative maintenance is limited to occasionally cleaning the optical faces of the detector components. Configuration Options OSID systems may be configured to suit a range of detection spaces by selecting the number of Emitters and type of Imager. Each type of Imager differs by the lens used in the unit, which determines the field of view and range of the system. Field of View 1 Detection Range Max. Imager - - r - '' , ' "- - - Number standard Power High Power of Horizontal Verbal Min . - . - Max Min Max Emitters 10° I r 4° I 30m(98ft) I 150m(492ft) I -- -- I i 45° I 38° I 19° 15 m (49 It) I 60 m (197 ft) 30 m (98 It) 120 m (393 It) I 90° 80° 48° 6 m (20 ft) *034 m (111 It) 12 m (39 II) 0*68 m (223 if) Maximum Distances measured for the Center Field of View of the Imager. For more details on distances for the Imager, see the OSID Product Guide. Emitter I Imager Dimensions riD IIi Ordering Codes 051-10 Imager -7° coverage 051-45 Imager - 380 coverage 051-90 Imager - 80° coverage OSE-SP-01 Emitter - Alkaline Battery OSE.SPW Emitter - Standard Power, (Mred OSID.EHE Emitter environmental housing 1P66 OSID.EHI Imager environmental housing 1P66 OSE.ACF Anti-condensation film for Emitters OSEH-ACF Anti-condensation film for OSlO- EHE and OSID-EHI environmental housings www.xtralis.com UK and Europe +4.4 1442 242 330 D-A-CH +49 431 23284 1 The Americas +1 781 740 2223 Middle East +96265885622 Asia +8621 5240 0077 Australia and New Zealand +61 3 9936 7000 The contents of this document are provided on an as is basis. No represents on or warranty (either express or implied) is made as to the completeness, accuracy or reliability of the contents of this document The manufacturer reserves the right to change designs or specifications without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any implied warranties of merchantability and fitness for a particular purpose era expressly excluded. Xtralis. Xtralis logo, The Sooner You Know, VESDA. ICAM, EGO. OSlD, Heilel, ADPRO, IntrosionTraca, and toilerTrace are trademarks and/ or registered trademarks of Xtralis and/or its subsidiaries in the United States and/or other countries. Other brand names mentioned heroin are for identitcadon purposes only and may be trademarks at their respective holder(s). Your use of this document dens net constitute or create a licence or any other right to use the name and/or trademark and/or label This document is subject to copyright owned by Xtralis. You agree not to copy, communicate 10 the public, adapt, distribute, transfer, sell, modify or publish any contents of this document without the express p/en written consent of Xtralis. 000, NO. 15211_21 Pert No. 29573 ,k1J .Ymacc& ! ) OSE-HPW Emitter - High Power, Wred OSID-INST OSID Installation Kit OSP-001 FTDI Cable 1.5m OSP-002 Laser Alignment tool OSID-WG \Mre Guard OSE.RBA Spare alkaline battery pack for Emitter units OSE-RBL Replacement Lithium Ion Kit CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. t7260-1728:01) Page 1 of 1 CATEGORY: 7260 - SMOKE DETECTION SYSTEM-BEAM TYPE LISTEE: XTRALIS, INC.175 Bodwell Street, Avon, MA 02322 Contact: Mark Schofield (781) 616-1124 Fax (781) 681-3149 Email: mschofield@xtralis.com DESIGN: ModelsbSI-10 OSI-45, 051-90 projected beam type smoke-automatic fire alarm. Units are comprised of an imager and emitter device. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20 - 30 vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as air sampling type smoke-automatic fire detectors. Refer to listee's Installation Instruction Manual for details. S 08-11-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification cf any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division - ','•'• 'S''r'x\ \ ;. SYSTEM $ SENSOR® Indoor Selectable. Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings on ceiling units: 15, 30,75,95, 115, 150, and 177 Automatic selection of 12- or 24-volt operation at 15 and 30 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) Speakers otter high fidelity and high volume sound output 520 Hz capable with compatible FACP Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products Tamper-resistant construction Updated modern aesthetics Agency Listings SIGNALING APPROVED LISTED S4046 FM approved except 7320-1653:0505 or ALERT models 3057493 System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L.Series makes installation easy Attach a universal mounting plate to a 4 x 4 x 2118 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mountinglplate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications 0 General [-Series speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model _________ listed to U[1480 and U[ 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync'Circuit model MD[3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box Electrical/Operating Specifications 6.9 in, 176 mm 5.37 in, 136 mm Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC or regulated 24 VDC/FWR 1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8t0 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power 1/4,½,1,2watts Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 and 30 cd. 520Hz capable with compatible FACP. 0 ~IWUUL IIl11I irT71.1 8 to 175 Volts Candela DC (ito Volts DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Setting Speaker Sound Output UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4W 1/2W 79 82 79 82 1W 85 85 2W 88 88 Ceiling-Mount Setting 1/4W Speaker Strobe Sound Output UL Reverberant (dBA @10 ft) 77 UL Anechoic (dBA @10 ft) 77 1/2W 80 80 1W 2W 83 86 83 86 L-Series Dimensions 1.00 6.80 dia Ceiling Speaker 6.80 dia Ceiling Speaker Strobe Surface Mounting S Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box L-Series Ordering Information White Red Description SPCWL SPCRL Speaker only *(SPSCWL) (SPSCRL) (Speaker Strobe) SPSCWL-P - Plain, Speaker Strobe SPSCWL-SP - Fuego, Speaker Strobe SPSCWL-CLR-ALERT - Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceilina Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring SYSTEM Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor for current product information, including the latest version of this data sheet. 5ALcOR Phone: 800-SENSOR2 • Fax: 630-377-6495 oductspecrhCauonssubtecttochangemthoutflOOceta5faystemseflSOrcom www.systemsensor.com AVDS86601 • 03/17 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 70-1653:0505J Page 1 of 2 CATEGORY: 7320 - SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: System Sensor Indoor Models: SPRL and SPWL Wall Speakers; SPCRL and SPCWL Ceiling Speakers; FFL—SRtjC _WL) SPSRL-P, SPSRL-SP, SPSWL-P, SPSWL-ALERT and SPSWL-CLR-ALERT Wall Speaker Stobes; SPSCRL, SPSCWL, SPSCWL-PPSCWSP and SPSCWL-CLR-ALERT Ceiling Speaker Strobes. Wall Bezel Parts: BZSPR-P, BZSPR-AL, BZSPR-EV, BZSPR-AG, BZSPR-PG, BZSPR-F and BZSPR-SP, BZSPW-P, BZSPW-AL, BZSPW-EV, BZSPW-AG, BZSPW-PG, BZSPW-F and BZSPW-SP, Ceiling Bezel Parts: S BZSPRC-P, BZSPRC-AL, BZSPRC-EV, BZSPRC-AG, BZSPRC-PG, BZSPRC-F and BZSPRC-SP, BZSPWC-P, BZSPWC-AL, BZSPWC-EV, BZSPWC-AG, BZSPWC-PG, BZSPWC-F and BZSPWC-SP, WallTrim Rings for Speaker Strobes: TR2 and TR2W CeilingTrim Rings for Speaker Strobes: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBSPRL and SBBSPWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires Qune3O, 2O1 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15,30,75,95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Aciencv Listinas SIGNAUNG (9 0 LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT r,rodels 7135-1653:0503 3057383 The System Sensor 1.-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. n L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts, Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V(12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 3.4' high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV0S86800 S UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts Candela DC 15 87 30 153 75 N/A 95 N/A 115 N/A 150 N/A 177 N/A UL Max. Current Draw (mA RMS), 2-Wire Horn 16-33 Volts DC 41 63 111 134 158 189 226 Strobe FWR 60 86 142 164 191 228 264 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 S AVDSw800 C L-Series Dimensions 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Hon Strobe, Red PC2WL 2-Wire, Horn Strobe, White Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White SYSTEM SENSOR ©2017 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject tochaegewithout notice. Visit syutentuensor.com Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product inforroahon, inctuding the latest version of this data sheet AVDS86801 .03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 51653:O504D Page 1 of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCR Ed Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: S LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W Ceilinglrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct a" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 is RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7320-1653:0505 Page 2 of 2 S RATING: 25 or 70.7 VAC, 1/4, 1/2, 1 2 Watt outputs. Regulated 12 VDC and 24 VDC/FWR is for 2-wire strobe portion. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as speakers and speaker-strobes when used with separately listed compatible fire alarm control units. Suitable for indoor use, dry and damp environments. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. S 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not VG an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division O SYSTEM Z.4, SENSOR® / Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. The System Sensor L.Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy Attach a universal mounting plate to a 4 x 4 x 2118 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. 0 Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings on wall units: 15, 30, 75, 95, 110,135,185 Automatic selection of 12- or 24-volt operation at 15 and 30 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) Seakers offer high fidelity and high volume sound output Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products Tamper-resistant construction Updated modern aesthetics Agency Listings SIGNAUNG S LISTED APPROVED 54048 FM approved except 7320-1653:0505 for ALERT models 3057493 L-Series Speaker and Speaker Strobe Specifications &Yr_'ritPcbjx?1/FTtr~TPPri-rr Rvprifir!:-fi~Tq 0 General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall- mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be a System Sensor L-Series model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model _________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch: and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 41 1/16 x 41 1/f 6 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 tc 93% non-condensing Dimensions, Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm .97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm (including lens and speaker) With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm Electrical/Operating Specifications Nominal Voltage (speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC or regulated 24 DC/FiNR12 Operating Voltage Range (includes fire 8t0 17.5 V (12 V nominal) or 16 to 33V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power 1/4,½,1,2wafts Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 and 30 Cd S 6 1.63 2.30 1.39 1.63 63 L-Series Dimensions S 5.00 .97 6 S UL Current Draw Data UL Max Strobe Current Draw (mA RMS) 8 to 17.5 Volts Candela DC 16 to 33 Volts DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A Sound Output Speaker Strobe 222 257 ¼W ½W 1W 2W UL Reverberant (dBA@loft) 77 80 83 86 ULAnechoic(dBA@loft) 77 80 83 86 Sound Output Speaker ¼W ½W 1W 2W UL Reverberant (dBA@loft) 79 82 85 88 ULAnechoic(dBA@loft) 79 82 85 88 Wall-Mount Speaker Wall-Mount Speaker Strobe 0 Surface Mounting Wall-Mount Speaker Strobe with SBBSPL Surface Mount Back Box L-Series Ordering Information IWall 1luMount White Red Description SPWL SPRL Speaker only (SPSWL) (SPSRL (Speaker Strobe) SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT - Speaker Strobe, Amber Lens SPSWL-CLR-ALERT - Speaker Strobe Clear Lens - SPSRL-SP Speaker Strobe, Fuego Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Rina Notes: All -P models have a plain housing (no "FIRE" marking on the cover) SYSTEM 3825 Ohio Avenue,. St. Charles, IL 60174 02017 System Sensor Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specificotc's subject to change nthout notice. Visit syuternoenso.com for current prod= info nation, including the latest version of this data sheet. wwsystemsensor.com AVDS86701 • 03/17 S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 0-1653:050 Page 1 of 2 CATEGORY: 7320 - SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor Models: SPRL and SPWL Wall Speakers; SPCRL and SPCWL Ceiling Speakers; (.P9RSv\1E) SPSRL-P, SPSRL-SP, SPSWL-P, SPSWL-ALERT and SPSWL-CLR-ALERT Wall Speaker Stobes; [SPSCRcSCWE' SPSCWL-P, SPSCWL-SP and SPSCWL-CLR-ALERT Ceiling Speaker Strobes. Wall Bezel Parts: BZSPR-P, BZSPR-AL, BZSPR-EV, BZSPR-AG, BZSPR-PG, BZSPR-F and BZSPR-SP, BZSPW-P, BZSPW-AL, BZSPW-EV, BZSPW-AG, BZSPW-PG, BZSPW-F and BZSPW-SP, Ceiling Bezel Parts: . BZSPRC-P, BZSPRC-AL, BZSPRC-EV, BZSPRC-AG, BZSPRC-PG, BZSPRC-F and BZSPRC-SP, BZSPWC-P, BZSPWC-AL, BZSPWC-EV, BZSPWC-AG, BZSPWC-PG, BZSPWC-F and BZSPWC-SP, WallTrim Rings for Speaker Strobes: TR2 and TR2W CeilingTnm Rings for Speaker Strobes: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBSPRL and SBBSPWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listees data sheet for detailed product description and operational considerations. 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: March 01, 2017 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7320-1653:0505 Page 2 of 2 RATING: 25 or 70.7 VAC, 1/4, 1/2, 1, 2 Watt outputs. S Regulated 12 VDC and 24 VDC/FWR is for 2-wire strobe portion. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as speakers and speaker-strobes when used with separately listed compatible fire alarm control units. Suitable for indoor use, dry and damp environments. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. S CS 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: March 01, 2017 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Outdoor, Selectable- Output Speaker Strobes and Dual-Voltage Evacuation Speakers SpectrAlert' Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features Plug-in design Electrical compatibility with legacy SpectrAlert products Shorting spring on mounting plate tests continuity before installation Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (14, ½, 1 and 2 watts) Ceiling- and wall-mount application Universal mounting plate for wall- and ceiling-mount units Weatherproof per NEMA 4X, 1P56 Compatible with System Sensor synchronization protocol Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units Agency Listings SISNAUN 0 G ® a MEA LISTED 75S0 7320-1650-201 10-08-f r L' from T, tern Sensor The SpectrAlert Advance series offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151°F. In addition, these speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. The entire SpectrAlert Advance line, including speakers, provides a plug-in design that reduces ground faults by enabling installers to pre-wire mounting plates and dress the wires before plugging in the speakers.To enable faster installation times, a shorting spring on the mounting plate provides instant feedback to ensure that wiring is properly connected. Furthermore, rotary switches simplify the selection of voltage and power settings. Both wall and ceiling speaker strobes include field-selectable candela settings that enable installers to quickly set each device to meet application requirements. The speakers'weatherproof plastic back boxes (shipped with product) and metal back boxes (available separately) are designed to accommodate in-and-out wiring for daisy chaining outdoor devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion.The screw-hole knock-outs located on the back of the back box eliminate the need to drill holes for screw-in mounting. Both weatherproof back boxes come with 1/4-inch top and bottom conduit entries and 3/4-inch knock-outs at the back. Included with each back box is a screw-in NPT plug with an 0-ring gasket for a water tight seal. Advance Outdoor Speaker and Speaker Strobe Specifications ieerinq SDecifications 0 General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync.Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4000 Hz and shall have an operating temperature from —40°F to 150.8°F. Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing 54048.The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall .ave a frequency range of 400 to 4000 Hz Speaker shall have power taps that are selected by rotary switch.The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts.The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75, 30, 75, 110, 115, 135, 150,177 or 185 candela when operating on 24 volts-The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°C to 66°C) Dimensions, Wall-Mount SPS Speaker Strobe 6.0"L x 5.0W x 4.7 D (including lens and speaker) SP Speaker 6.0"L x 5.0W x 2.9 D Dimensions, Ceiling-Mount SPS Speaker Strobe 6.8 Dia. x 4.7 D (including lens and speaker) SP Speaker 6.8 Dia. x 2.9- D Dimensions, Wall-Mount Weatherproof Back Box 6.5 Lx 5.5 H x 2.9"D Dimensions, Ceiling-Mount Weatherproof Back Box Electrical/operating Specifications 72' Dia. x 2.9'D Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers) 50VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24V nominal) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4000 Hz Power - '/4,½,1,2watts A05-0425-005 S Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output JI Listed Candela Candela rating at -40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 7.19- 7.14 Ceiling-Mount Outdoor Speaker Strobe Wall-Mount Outdoor Speaker Strobe I—M UL Max. Strobe Current Draw ImP 8t0 17.5 Volts (1to3Volts Candela DC FWR DC FWR (Standard) (f) ~23,, (i8D 0) (Candela Rang (577_) (i) 13 (RA) çN A) (1578 (15~3 (High)__ (Candela Rangj F15 0 WA, () I) (T7 (N A, () Cl 85) (\TA) Sound Output UL Reverberant (dBA@lOft.) 2W 1W ½W ¼W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 S Dimensions 7.19 Ceiling-Mount Outdoor Speaker 0 Wall-Mount Outdoor Speaker A05-0425-005 Surface Mounting of as Ceiling-Mount Speaker Strobe with Plastic Weatherproof Back Box Ceiling-Mount Speaker with Plastic Weatherproof Back Box Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box as as Ceiling-Mount Speaker Strobe with Metal Weatherproof Back Box Ceiling-Mount Speaker with Metal Weatherproof Back Box lit 41 I!L1J Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Ordering Information for SpectrAIert Advance Outdoor Speakers and Speaker Strobes I!F1lFir1T1i1 White Red (SPWR) SPRK (OtdoorSker box)) SPSWKt SPSRKt Outdoor Speaker Strobe, Selectable Candela (15, 15/75,30,75,95, 110, 115) (includes plastic weatherproof back box) - SPSRI-IK Outdoor Speaker Strobe, Selectable Candela (135,150,177185) (Includes plastic weatherproof back box) Ceiling Mount_ White Red Description SPCWK - Outdoor Speaker (includes plastic outdoor back box) SPSCWK - Outdoor Speaker Strobe, Selectable Candela (15, 15/75,30,75,95, 110, 115) (includes plastic weatherproof back box) SPSCWHK - Accessories Outdoor Speaker Strobe, Selectable Candela, High cd (135, 150, 177, 185) (includes plastic weatherproof back box) White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box MWBBCW - Ceiling, Metal Weatherproof Back Box Notes: Add "-R"to model number for weatherproof replacement device (no back box included), e.g., SPWK-R. Especially for use with weatherproof outdoor flush mounting plates, WTP-SP and WTP-SPW tAdd "-P"to model number for plain housing (no"FIRE" marking on cover), e.g., SPSWK-P. S}'STEII,7 SENSOR Phone: 02 09 System Set—. 3825 Ohio Avenue. St. Charles, IL 60174 800-SENSOR2 . Fax: 630-377-6495 current productinfwnation, including the latestvef~m of this dam sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I'JJ LISTING SERVICE LISTING No. (70-1653:0201) Page 1 of 1 CATEGORY: 7320 - SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models SPR1SSPRV, and SPWV SpectrAlert Speakers - Rectangular enclosure. Models SPCW, SPCR, SPCWV, and SPCRV SpectrAlert Speakers with round enclosure. Models SPSR, SPSRH, SPSW, SPSW-ALERT, SPSW-CLR-ALERT, *SPSWK..CLR..ALERT SPSWH, SPSRV, and SPSWV SpectrAlert Speaker/Strobe with rectangular enclosure. Models SPSCR, SPSCRH, SPSCW, *SPSCWKCLRALERT SPSCWH, SPSCRV, SPSCRVH, SPSCWV, and SPSCWVH SpectrAlert Speaker/Strobe with round enclosure. Model SPSCW-CLR-ALERT Speaker/Strobe. Model SPSW-ALERT has amber lens and is intended for non-fire use. All models identified are intended for indoor use mounted on the wall or ceiling. Models with a ' in the suffix are suitable for indoor or outdoor use with an operating temperature rating of -40°C to +66°C (-40°F to +151 °F) and have a NEMA 4X enclosure rating when used with models PWBB, PWBBW (wall) or the model PWBBCW (ceiling) plastic weatherproof back boxes or with Model MWBBW (Wall), MWBB (Wall) or MWBBCW (Ceiling) metal weatherproof back boxes. Models with a "- P' in the suffix have plain housings with no . lettering on the enclosure. Models not containing "- P", in the suffix have English lettering reading "FIRE" on the housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Nominal Voltage: 25 Vrms or 70 Vrms Power Settings: 1/4, 1/2, 1, 2 Watts Frequency Range: 400 - 4000 Hz INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as speaker/strobes when used with separately listed compatible fire alarm control units. Suitable for wall or ceiling mount. These speaker/strobes do not generate a distinctive three-pulse temporal code pattern (for total evacuation) as required per NFPA 72, 2010 edition. If required, the appliances must be used with a fire alarm control unit that can generate the temporal pattern signal. *Corrected 02-06-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VOC setting: 8-17.5VDC Regulated 24 VDC/fwr sethng: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: February 16, 2017 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division !18