Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 218C; FPC2017-0352; PermitPERMIT REPORT C U,it arlsbad Print Date: 01/20/2022 Permit No: FPC2017-0352 Job Address: 2525 EL CAMINO REAL, # 218C, CARLSBAD, CA 92008-1208 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel 4*: 1563020900 Track 4*: Applied: 11/28/2017 Valuation: $68,279.60 Lot 4*: Issued: 12/15/2017 Occupancy Group: Project 4*: Finaled Close Out: 02/08/2021 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Inspector: Plan Check 4*: Final Inspection: Project Title: Description: LUCHA UBRE -FIRE ALARM TI Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP SIMPLEX GRINNELL LP DOUGLAS DANIELS 3568 RUFFIN RD S 3568 RUFFIN RD SAN DIEGO, CA 92123-2597 SAN DIEGO, CA 92123-2597 (858) 633-9100 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department - Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tq!;Ij SirnplexGrinnell SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Fire Detection and Alarm System Product Submittal Project: Lucha Libre The Shoppes at Carlsbad 2525 El Camino Real Suite 218C Carlsbad, CA t\ 0 FPC20I7-0352 218C 2525 EL CAMINO REAL LUCHA LIBRE - FIRE ALARM 1563020900 11/28/2017 FPC20I 7-0352 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or ddaniels(äsimplexqrinneIl.com 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco. tqca ell SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 2 4098-9755 Duct Detector 3420-0026:0241 2 2098-9806 Remote Test Station 7300-0026:0150 1 4090-9001 Supervised lAM 7300-0026:0223 3 4090-9010 Relay 1AM 7300-0026:0311 2 4906-9204 Strobe 7125-0026:0235 3 49SV-APPLC Speaker Strobe 7125-0026:0384 Business Information Warranty Information S S 11/28/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco. TM Duct Sensor Housing, Front and Bottom View 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station B®SimpIEx TrueAlarm Analog Sensing 5 UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control I1(Ii(*I Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNet or MAPNET H, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNetJMAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control . At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) S * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. lTTri Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. S4098-0030-10 11/2014 III lri1d IiTMe- Control Panel Selection. Peak activity per sensor is Typically duct sensor applications require less sensitive stored to assist in evaluating specific locations. The alarm settings (such as 2.5% per foot obscuration) due to the set point for each sensor is determined at the control ducts being a relative dirty environment. However, the panel, selectable as the individual application requires. standard seven levels of TrueAlarm sensor sensitivity are Sensor Status LED. Each sensor housing's red status available for each individual sensor, ranging from 0.2% to LED (located on the electrical interface board) pulses to 3.7% per foot of smoke obscuration. Sensitivity is s indicate communications with the panel. If the control elected and monitored at the fire alarm control panel. panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's • Individual smoke sensitivity selection status LED will be turned on steadily. During a system • Sensitivity monitoring that satisfies NFPA 72 alarm, the control panel will control the LEDs such that sensitivity testing requirements an LED indicating a trouble will return to pulsing to help • Peak value logging allows accurate analysis for identify any alarmed sensors. (Remote Status/Alarm sensitivity selection LEDs track the operation of the sensor housing LED.) Automatic, once per minute individual sensor calibration check verifies sensor integrity TrueAlarm photoelectric sensors use a stable, pulsed • Automatic environmental compensation infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language Relays of model 4098-9756 are under panel control for ON, OFF, or override II11i!i.] 1I1'ThI Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility -9755 either IDNet or MAPNET II communications (no relay 4100E, and 4120: Also 2120 CDT if configured for _out MAPNET-H Try Alarm operation Duct Sensor Housing with supervised multiple relay output Same as above except relay operation is not 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 compatible Nith 2120 CDT; end-of-line resistor harness; includes one 4098-9843 relay Relay 0UtpL t is for up to 15 total 4098-9843 Relays (additional ielays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator on single-gang stainless steel plate Use single gang box, Test Station with keyswitch and red LED status indicator, on 409 9755 3" H x 2" W x 2" D 2098-9806 single-gang stainless steel plate; (turning switch to "TEST" 4098-9756 (76 mm x 51 mm x 51 mm) initiates alarm for system testing) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 40989 Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; connect '!' (1 m) of device being wiring is 18 AWG (0.82 mm2 ) color coded wire leads 15 controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kr), 1/2W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One Overall Duct Width (305 mm) Tube Required 4098-9854 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 4098-9855 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 4098-9856 3 in" (76 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 4098-9857 3 in" (76 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 4098-9858 3 in" (76 mm) longer than duct width S4098-0030-10 11/2014 S I .i:rirn nti riiu NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information. I 11-3/8(289 mm)_______________J I Exhaust tube access hole 1 I 4098-9714 Smoke sensor, mounted in special interface base (supplied) 6-3/4 . - (171 mm) Sampling tube access hole Metal plate with dual holes for 3/4 (19 mm) conduit plug supplied for unused hole 13D1]DDUU I 0 MUD i M 00 Yellow LED, relay control trouble indicator (4098-9756 only) 13 II Ill Red sensorl status LEDJ screws NOTE: Orientation shown is for reference sensor are only, refer to General Location Notes and End View illustration below for alternate mounting reference. S Duct wall (21 mm) I Test ports (2) provided for measuring airflow and for aerosol injection Exhausttube I (supplied) Sampling tube, ordered separately per duct width 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 1-3/16" (30 mm) 1-1/2" 13/16" (38, mm) (21 mm) Square duct reference outline Lternate location arrnroriate) 18" Round duct outline [iameter --- IYATTATg Li Duct _________________ housing __________________ O 8" Square duct outline (minimum width) DO NOT MOUNT ON BOTTOM OF DUCT /\ 3 Sampling tube, keyed for proper hole alignment with holes facing into airflow (template is provided for proper tube installation). (I-lousing is shown as position 2 per note 2 below.) General Location Notes: Testing performed under the auspices of the Fire Detection Institute (FDI) recommended when sampling tubes are not located vertically, that they be positioned horizontally in the upper half of the duct to account for possible stratification. Three duct side mounting options are available as shown below. Mount housing at 90° to airflow for all orientations. Arrows indicate allowed airflow directions. t , ® ® U S4098-0030-10 11/2014 Duct Sensor Location Reference Exhaust Damper Sensor OK Exhaust .4-r II Return Air Do not locate sensor here Return air damper Fresh air -+- Supply Air Do not locate Filter bank Sensor OK sensor here Additional Information. Refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems; NFPA 72, the National Fire Alarm and Signaling Code; and the NEIl'L4 Guide for Proper Use of Smoke Detectors in Duct Applications, and Installation Instructions 574-776. Duct Sensor Location Considerations: Proper duct smoke detection location must ensure adequate airflow within the duct housing. Duct air velocity rating is 300 to 4000 ft/min (91 to 1220 mlmin). Pressure differential between intake and exhaust tubes is required to be between 0.015 to 1.55 inches of water (0.381 to 39.37 mm). Ensure accessibility for test and service. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. Other locations and orientations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. C General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range • 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color and Material Black ABS base with clear polycarbonate cover Sampling and Exhaust Tube Material Black CPVC, custom extrusion; sampling tubes are pre-drilled Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 012098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current 15 mA @ 24 VDC; add 15 mA for each 4098-9843 relay Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kI), 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @28 VDC & 120 VAC; 250 jiA @ 5 VDC Location t. Distance 500 ft (152 m) maximum to relay coils; locate relays within 3 ft (1 m) of device is being controlled per NFPA 72 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). B S - I x Tyco Fire Protection Products• Westminster, MA 01441-0001 • USA S4098-0030-10 11/2014 viww.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved All spec/lcations and other information shown were current as of document revision date and are subject to change without notice. C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4098-9755, 4098-9755TSP, *40989755up 4098-9756, *4098..9756TSP 4 8- 5 , 4 98-9685, 4098-9686, 4098-9687 and 4098-9618 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098 688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube ar d an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 -4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and L L label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. 5 NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S C S BSimpIEX UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I T11uI(4-1 IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007ES, 4008, 4010, 4010ES, and 4100ES fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.9 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings- MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet and MAPNET II Communicating Devices, Individual Addressable Modules (lAMs) SlT[t 1kD R[COff[t CO 4090.90 SUt[Atis[9®0 'liI Il kIlt 04-iti DATE CODE 9001 Supervised lAM approximately 3/4 size) U USED0 4ALINS DEv - 4090-9051 Supervised lAM (shown approximately 3/4 size) Dqrrintk Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET H or IDNet circuit. They provide location specific acdressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. S4090-0001-12 8/2016 RIM I 1 Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). [II! 11 nh!Th1iZ Iii For use with IDNet communications only, these lAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. S lAM Product Selection Model I Descri 4090-9051 1 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, r 4090-9807 For surface mounted box includes mounting screws; galvanized al ires 4090-9810 mounting bracket, 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes ftr trim plate, required for optional trim I plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kQ, 1/2W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 1 733-896 14.7 k, 1/2 W Use for current limited monitoring applications 4081-9005 1 733-984 1 1.8 kc, 1/2W Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections - 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wnng Diagrams 574-331 for 4090-9001; 579-572 for 4090-9051 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference 2500 ft (762 m) maximum from fire alarm control panel IDNet Communicationsper channel, MAPNET or 0ft3048) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 4090-9051 1-9/16" W x 1-3/4" H xl-1/4" D (40 mm x 44 mm x 32 mm) 1-9/16" W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-12 812016 C S Mounting Information C 4090-9001 IDNet supervised lAM 1 I II I I II t I II I I IlSI II II I Ii' II I Field wiring shown for reference 0 LED viewing port C Single gang electrical box 2-1/2' (64mm) I minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 4-1/4' (108 mm) @ nn fl[ © CD _ Light pipe for LED viewing r 1 (114 MM) SOONMEGT POWER DSOC•NNECT POWER E.EFORE SERVICIRO [EEFOF(: SERVCWG © © CD 2-1/2" __ (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2-1 3/16" __ (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-12 8/2016 4090-9051 Mounting Information Address setting is at rear of housing 4090-9051 Encapsulated Supervised lA Q Single gang electrical box 2-1/2 (6/-mm) minimum depth (supplied by cthers) Single gang blank cover plate and S mounting screws (supplied by others) S ®Si in plEx Tyco Fire Protection Products • Westminster, MA 01441-0001• USA S4090-0001-12 8/2016 CO 2016 Tyco Fire Protection Products. All rights reserved. All speqficatiorvc and other information shown were current as ofdocument revisiol dale and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexiQO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: (l 1-9001TSP, -900111P, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002T5P, and -9002TTP lAM Relay Module; 4090-9 06, -9106TSP, and-910611P Class "A" ZAM Initiating Module; 4090-9101, -9101 SP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Referto listee's data sheet for additional detailed product description and operational conside ations. RATING: 24VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applica fle codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: S *Rec 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) Communications IDNet communications 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4W'Hx4"Wx1%"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32* to 120* F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 5®Sim plEx S UL, ULC, CSFM Listed; FM Approved* I1uI*1 Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For IDNet communications from the following Simplex® control panels: Model Series 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 /t" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow S LED to be viewed after installation UL listed to Standard 864 Epscrintk 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Model Description 4090-9010 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 For semi-flush Trim plate, galvanized mounted box steel, with LED viewing 4090-9802 For surface window; includes mounted box mounting screws 4090-9813 Adapter plate to fit (119 mm) square electrical box S * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM S4090-0015 9/2014 18 Relay tAM Mounting Information S 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © Add supplied label to wARwjr. I MIM No Kra[ ON NOMMIUMMIN AVERflSSNT:I cover on-site if controlling IAvERnssn:mime 4-9/16" MMUMIN 120 01240 VAC 4-5/16" (116 mm) (109mm) © Light pipe for LED viewing © 4-9/16" (116 mm) 10 , -4-5/16(109mm) 4090-9801, Trim plate for 4090-9802, Trim plate for— semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly proh,bited. ®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4090-0015 9/2014 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) r module with unsupervised feedback, 4090-9008 dual relay IAf( lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applica le codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately Ii ted compatible fire alarm control units. S *Rev. 04.24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S 5SimpIEx TrueAlert Addressable Notification Appliances UL, ULC, CSFM Listed; FM Approved; [71 Multi-Candela Visible Only (VIO) MEA (NYC) Acceptance* L.ftJ Appliances (Strobes), Ceiling Mount S S Ii1I I(}-1 Individually addressed and controlled multi-candela VIO (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and ULCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:235 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simples Time Recorder Co. are the property of Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os "IM11-14M Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) I1 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. I lT71 RE IFTE. r Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) TrueAlert Addressable Diagnostics Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSlT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Product Selection Multi-Candela Ceiling Mount Addressable Strobe Model Housing Color I "FIRE" Lettering Dimensions Description 4906-9202 Red White ________ Red 4h"x2 5A6"x2 % D (121 mm x 75 mm x 67 mm) Multi-Candela Addressable Strobe; intensity selectable as: 15, 30, 75, or ________ 4906-9204 White 110 candela VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Ceiling Mount, Surface Mount Adapter Plate, zinc plated; required for 4 %"x 3 %' (124 mm x 79 mm) ceiling surface mount Wire Guards (see diagram on page 3) Model I Description I Dimensions 49059926* Ceiling Mount Red wire guard with mounting plate, compatible with I 6 %" x 4 %" x 2 %" semi-flush or surface mounted boxes I (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/O 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 2 S4906-0004-4 2/2015 S [11 S Ceiling Mount V/0 and Guard Installation Reference n Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or Single gang box (Wiremold V57445) -1--L.. equal) or single gang box, 2-1/2' (64 mm) deep 2-1/4" (57 mm) deep, supplied by others (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) Address setting DlPswitch is behind strobe assembly, select address and strobe 4905-9910 Adapter Plate, required for surface candela setting before inserting into housing () /' mount with handy box unless using the 4905-9926 / wire guard Ceiling mount strobe Bottom view . Magnetic -1 test location Optional 4905-9926 wire guard with mounting plate - Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is FACP, LED indicator/ : controlled by panel Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4007E5 with IDNAC Notification S4007-0002 4010ES with ESS Enhanced System Supply S4010-001 1 Specifications General Specifications (see page 2 for dimensions) Environmental 132° to 122" F (0° to 50" C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per I terminal for in/out wirinq Installation Instructions 579-808 Strobe Specifications Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per NAC Candela Setting 15 cd 30 cd I 75 cd 110 cd 23 VDC RMS Current Ratings, for connection to IDNAC Addressable SLCs 60 mA I 92 mA I 180 mA I 240 mA TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensity Appliance Voltage Minimum 4100ES or 41001-1 with TrueAlert Power Supply S4100-0031 TrueAlert Addressable SLC 15, 30, 75, and 110 cd .17 VDC 4009 TPS, Remote TrueAlert Power Supply S4100-0037 TrueAlert Addressable Controller (4009T) S4009-0003 Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 cd 30 cd 75 cd 110 cd 17 VDC RMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above S4906-0004-4 2/2015 S S C TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). B®S i rn p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4906-0004-4 2/2015 www.simplexgrinnell.com 0 2015 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0235 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models "TrueAlert non-addressable" 4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable "4904-9168,4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models "TrueAlert addressable" 4906-9201, -9202, -920 -9204, nd -9208 synchronized multi-candela strobe lights are intended for indoor use. * o e s 4 06-9201, -9203 and -9208 are intended for wall mounted only. *Models 4906-9202 and -9204 are intended for ceilingl mounted only. Intended for use with either Model 4209-9401 NA Extender or with the TrueAlert power supply of Model 4100U fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data she] for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -9359, -9168, -9171: i5cci, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. "Rev 04-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division B.SiMPIEX UL, ULC Listed; FM Approved* TrueAlert Addressable Notification Appliances Ceiling Mount Addressable Speaker Visible If"(SN) Notification Appliances Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). SN notification appliances use a multi-tapped speaker for audio/tone notification and a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Ceiling mount speaker visible appliances are available in 400 - 4000 Hz models and high fidelity models capable of operating between 200— 10000 Hz. Separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWC-000 1. Ceiling Mount Addressable SpeakerNisible Notification Appliance IrE1 Ceiling Mount Addressable Speaker SN Appliances lrueAlert ES Addressable SN appliance dimensions with cover: 8 1/ " H x 7 ',4"W x 3" D ( 206 mm x 180 mm x 76 mm) -------------- . ., .... 4 SV- PPLC(-BA S eaker Visible a pliance only. Select cover separately. High Fidelity Appliances Model Description 49HFV-APPLC(-BA) High Fidelity appliance only. Select cover separately. High Candela Appliances Model Description 49SVH-APPLC(-BA) High Candela appliance only. Select cover separately. High Fidelity High Candela Appliances Model Description 49HFVH-APPLC(-BA) High Fidelity High Candela appliance. Select cover separately. 49HFVH-APLCA-BA High Fidelity High Candela appliance with amber colored lens. Select cover separately. 49HFVH-APLCB-BA High Fidelity High Candela appliance with blue colored lens. Select cover separately. SN Covers (Required when ordering APPLC models) Model Color lWording Model Color Wording 49S VC-CRALT ALERT 49SVC-C WALT ALERT 49SVC-CRBA -./FIRE 49SVC-CWBA LJ-/FlRE 49SVC-CRBC */FlRE ALARM 495VC-CWBC */FIRE ALARM 49SVCCRBF Red FEU/FIRE 49SVC-CWBF White FEU/FIRE 49SVC-CRFEU FEU 49SVC-CWFEU FEU 495VC-CRFIRE FIRE 49SVC-CWFIRE FIRE 49SVC-CRS Simplex logo only 49SVCCWS Simplex logo only 49S VC-CK Black I No logo or lettering * Note: (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in —BA are assembled in the USA * Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire S49SVC-0001-2 11/2016 S IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 4100ES Constant Supervision and Signal Cards 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 CeIing_Mount SN Specifications 'Aflfl I ILfl I fl L1 I •L'J.lJ'JI!.IlL•tIIIII I1JI Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Conne ti C 0 Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Installation Instructions 579-1203 (49SV, 49SVH and 49HFV models) 579-1206 (Amber/Blue 49HFVH model) Speaker General Specifications 25 or 70.7 Vrms Power Taps I1/,/2, 1, and 2W 400 to 4000 Hz (SN, SNH), 200 to 10000 Hz General Signaling = 125 to 12 kHz I Frequency Response (H/F, HFNH) Speaker Output Ratings 25 or 70.7 Vrms @ 10 ft (3 m) Wattage Tap Model 1/4 W Y2 W I W 2W SN H/F SN I H/F SN I H/F SN H/F Reverberant Chamber Test, per UL 1480 (dBA) 79 76 83 80 86° 84 89° 87° Anechoic Chamber Test, per ULC-5541 (dBA)* 79 78 83 1 82 86° 1 85° 89* 88° Select taps as indicated to satisfy the ULU tire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-5541 Anechoic Chamber Attenuation Angle Attenuation Angle Testing) -3 dB 70° -6 dB 80° Percentage of rated light output at room temperature Angle On-Axis Vertical, Below Axis Horizontal, Left/Right of Axis 0° 45° 900 45° 90° UL required output 100% 45% 25% 45% 25% Typical output 327% 134% 83% 129% 47% Operating Voltage Range 23 VDC to 30 VDC, Spe al Application Supervisory Requirements 1 unit load (= 0.8 mA Co trol panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 sync circuit, max 127 SN app ronized strobes maximum per powered iances per IDNAC channel Candela Setting Current consumption** 495V and 49HFV models 49SVH and 49HFVH models I5cd 30cd - 5cd II0cd I35cd I85cd N/A 295 mA 59 mA 82 mA 1 .5 mA 193 mA N/A N/A N/A /A 235 mA 255 mA - -_ BJQ . . .. . . A 1. 1. . . k..t . A A i. L . A.&A A &AA k Note: Speakers are tor connection to compatible fire alarm audio circuits. Anechoic speaker out ut ratings are typically more representative of actual installed sound output. S S 2 S49SVC-0001-2 11/2016 S S Ceiling Mount S/V Installation Reference Appliance with cover (front) Magnet test location indicated by area that I e is not textured 043 ;K iç , ; 0000p, '00 a 00%00000 00000 0 C -000000000 00 '0 00000000000 00 00000000000 A liance test points, e00Ooco000000°o00000 0000000000000000,00 audio circuit power taps Coe 0 0 and address dip switch 000 0 0 000 ODQ,c 000 0 00 Set audio circuit power taps and \\ ' '° / / 4)000 device address before fixing \ \,0cceoc0/ cover in place. \ Mount to 4" X 4" X 2-1/8" Appliance (rear) electrical box using 8-32 screws Note: Ceiling mount only Wiring terminals for speaker Candela flag setting 1 = : - and strobe connections Set flag to FACP to control : - jj accept 2 #12-18 AWG wires candela rating from an FACP providing IDNAC notification. - - - - To set candela manually, set ,' 110 75 the flag to the desired 30 candela rating. I Use slotted screwdriver FACP , here to remove cover. S S 3 S49SVC-0001-2 11/2016 S S S TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and SinLsiing Code are ress1ered trademarks of the National Fire Protection Association (NFPA). 1 p1 EX Tyco Fire Protection Products• Westminster, MA 0 144 1-0001 USA S49SVC-0001-2 11/2016 www. simplex-fire. corn © 2016 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument rm'ision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: I 49SV-APPLC, HFV-APPLC,49SV-APPLC-BA,49HFV-APPLC-B ,49SVH-APPLC-BA, - C-BA,49SVH-APPLC,49HFVH-APPLC,49SV-CWF 49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mountedSpeaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,49SV-APPLW-BA,49HFV-APPLW BA,495V-WRF and 49HFV-WRF True Alert ES, Addressable wall mounted Speaker/Strobes. Models: I 49S0-APPLC, 49HF-APPLC, 4950-APPLC-BA, 49H F-APPLC-B4,4950-CW and 49HF-CW True Alert ES, ceiling mounted Speakers. Models: 4950-APPLW, 49HF-APPLW, 49S0-APPLW-BA, 49HF-APPLW-BA,49S0-WRF and 49HF-WRF True Alert ES, wall mounted Speakers. Models: 49SVC-CK,49SVC-CRALT,49SVC-CRFl RE,49SVC-CRS,49SVC-CRBC,49SVC-CWBC, 49SVC-CWFI RE,49SVC-CRFEU,49SVC-CRBF,49SVC-CWALT,49SVC-CWBA,49SVC-CRB A,49SVC-CWS,49SVC-CWBF and 49SVC-CWFEU True Alert ES, Speaker/Strobe Ceiling Mount Dress Covers. Models: 49SVC-WRALT,49SVC-WRBA,49SVC-WRBC,49SVC-WRBF,49SVC-WRFEU,49SVC-WRFI RE,49SVC-WRS,49SVC-WtNALT,49SVC-\AMIBA,49SVC4MNBC,49SVC-WWBF,49SVC-W WFEU,49SVC-WNFIRE and 49SVC-WNS True Alert ES, Speaker/Strobe wall Mount Dress Covers. Models: 4950C-CWFI RE,49SOC-CRFIRE,49S0C-CRS,49S0C-CWS,4950C-CK,4950C-CR, 49S0C-CW,49S0C-CWALT and 49S0C-CRALT True Alert ES, Speaker Ceiling Mount Dress Covers. 12-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0026:0384 Page 2 of 2 Models: 49SOC-WRFEU,49SOC-WRBF,40SOCWRBC,49SOC-WRBA,49S0C-\MNS,49SOC-WNFI RE,49S0C-WRBLAN K,49SOC-WRFlRE,49SOC-WRS,49SOC-WNBA,49SOC-VVW6C,49S OC-WNBF,49S0C-\MNFEU,49S0C-WWBLANK,49S0C-WWALT and 49S0C-WRALT True Alert ES, Speaker Wall Mount Dress Cover. Models: 49MP-SVWR,49MP-SVWN,49MP-SOWR and 49MP-SO\MN True Alert ES,Back Plates. Models: 495V-LENS-AMBER,495V-LENS-BLUE,495V-LENS-RED and 495V-LENS-GREEN True Alert ES, Colored Lens Kit. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signalling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. 12-08-15 gt This listing is based upon technical data submitted by the the test results and/or other data but does not make an independent applicant. CSFM Fire Engineering staff has reviewed verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division me rqgq SimplexGrinnell SirnplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2019 This license is current and active. All information below should be reviewed. C1 - ELECTRICAL . C16 -FIRE PROTECTION CONTRACTOR El Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2017 Expire Date: 10/01/2018 Workers' Compensation History Personnel listed on this license (current or disassociated) are listed on other licenses. S 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco. T111 0 tqca ell SimplexGrinnell LP 3568 Ruffin Road Sari Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the is submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 11/20/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco.Th4