Loading...
HomeMy WebLinkAbout5928 FARNSWORTH; ; AS150270; PermitCity of Carlsbad Sprinkler Permit Permit No: AS150270 5928 FARNSWORTH Job Address: CT Permit Type: SPRINK Parcel No: 2120701000 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 9/10/2015 Approved: 9/24/2015 Issued: 9/24/2015 Inspector: Project Title: BLDG C OFFICE Tenant Improvement to existing 1st and 2nd floor office space Applicant: ACTION FIRE SYSTEMS CO INC 9185 HARNESS ST SPRING VALLEY CA 619-462-9210 Owner: CARLSBAD TECHNOLOGY INC 0/0 ANDY CHENG 5922 FARNSWORTH CT CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 283 0 283 0 AS150270 Page 1 of 4 N I KJ NG* 8 MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector: Brass UNS-C23000 or Copper UNS-C19500 The Viking Corporation's Web site at Bulb: Glass, nominal 3 mm diameter http://www.vikinggroupinc.com. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent PTFE Tape Screw Brass UNS-C36000 edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- S30400 For Polyester Coated SrinkIers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 Rev 15.1 (Corrected K-factor on P/N 06661 B, Page 3) Page 2 of 4 'J IKII1GI MICROFAST® QUICK lsl:lI['i ,7w RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER•Iiil;ATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambieni Bulb Color :Cl assificátion . Temperature Rating' CeilingTemperaturé2 Ordinary 135 F (57 C) 100 °F (38 °C) Orange Ordinary 155 ¶ (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 C) 225 °F (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PIFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap- Wrench Flat Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_052114 Rev 15.1 Page 3 of 4 NlKjw4ja - MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikinqcorp.com ApprovaiCharti (UL) TsmP6rawre KEY McrofastQuick Response Eutcheon EAX (5 appli..abj Uprignt Sjirinkler VK300 MaxirTlum 175 PSI (12 bar) WJVP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals' SIN Number1 NPT I BSP U.S. Tnrl Inches mm cULus VdS LPCB (E 12978 VK300 1/2' 15 mm 5.6 1 80.6 2-3/16 56 Al, B2 -- -- L.11f Availabilityt77 Local Viking 1iIt 06661B VK300 1/2" 1 15 mm 1 5.6 1 80.6 11 2-3/16 56 1 Al, B2 -- I -- -- Approved Temperature Ratings Approved Finishes A - 135 °F (57 °C), 155 °F (68 °C) 175 °F (79 °C), 200 °F (93 °C), and 1 - Brass, Chrome, White Polyester56, and Black Polyester5'6 286 °F (141°C) 2 - ENT6 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. DESIGN CRITERIA UL (Also refer to Approval Chart 1 above) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 15.1 Page 4 of 4 NlKjw4 MICROFAST@ QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2r (FM) Thmp KEY Microfast Quick Response Upright Sprinkler VK300 (5 eppcbe) Maximum 175 PSI (12ba) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric Inches mm 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 NOTICE flProduct IJTaLocal Viking t•JilT 06661B VK300 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes 1 -Brass, Chrome, White Polyester', and Black °C), °C), °C), °C), A- 135°F (57 155°F (68 175°F (79 200°F (93 and 286°F (141°C) Polyester' B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA FM (Also refer to Approval Chart 2 above FM Anoroval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 15.1 (Corrected K-factor on P/N 06661 B, Page 3) Page 1 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT "4J II(IF t1Gi® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com 1. DESCRIPTION Viking Mirages Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pie-assembled with a threaded adapter for installation with a low-pro- file cover assembly that provides up to 1/2 (12.7 mm) of vertical adjustment. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as cor- rosion resistant as indicated in the Approval Charts. The ENT finish is only available fnr +ha onrr,L'Inr eeamkIii th rrn,nr l,,+n it, nn+ nl,,+mr4 fl/I U l IIIIflII Ci0OI I lilly, 11ICU 10 I Lii 1J1LiLLi14. I - I Viking Technical Data may be found on The Viking Corporation's Web site at http:IIwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C 19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze U N S-051 000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Rev 15.1 (Added CCCF Approval) Page 2 of 6 MIRAGE® STANDARD AND 4J IF(1I1Gi i:II[.u'ytIf. QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 °F (57 °C) UL (139°F (59 °C) FM and LPCB) = A, 165 °F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135°F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031°°° (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) —Requires a %" ratchet (not available from Viking). —Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 Rev 15.1 Page 3 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT "i4J II(II,416 ®TECHNICAL DATA SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum A'riibient I Temperature Rating of Cover Bulb Color Classifiëation Temperature Rating' Ceiling lempératüre2 Assembly (Required) Ordinary 155 OF (68° C) 100 OF (38 °C) 139 °F(59 FF and LPCB Red Intermediate 175 OF (79 °C) 150 OF (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 OF (65 °C) 165 OF (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings': ENT Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Approval Chart I (UL) Mirage'ConcealedPendentSprinklers VK462 and VK463 L±-* CoverPa Fn KEY NPT Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Inch mm J.S. metric2 cULus5 NYC VdS7 LPCB Base Part No.1 Pressure Standard Response Applications -- I -- AY1, CZ1 I AY1, BZ1 AY1, CZ18 AV1, CW1 13503A I VK462 ] 1/2" I 15 5.6 80.6 175 psi (12 bar) I Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 - - -- -- 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 - - -- -- 13667A VK463 1/2" 15 5.6 80.6 1 250 psi (17.2 bar)3 AV1, BX1 AV1, BW16 -- -- -- -- Cover Plate Assembly Temperature Ratings' Sprinkler Temperature Ratings V - 135 OF(570) cULus Listed cover 135041, 136421 (large dram- eter), or 153941 (square cover Finishes" Cover Plate Assembly Finishes A 155 OF (68 °C) W - 165°F (74 °C) cover 135041 or 136421 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, B -175°F (79 °C) and 200°F (93 °C) x - 165°F (74 °C) cover 135041, or 136421 (large diameter) Antique Brass, Brushed Brass, Brushed Copper, C -200°F (93 °C) Y - 135°F (57 °C) cover 135041 LPCB Approved as 139°F (59 °C) Painted White, Painted Ivory, or Painted Black Z - 165 OF (74 °C) cover 135041 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional ap- provals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 9 The 135/139°F cover has an orange label. The 165°F (74 °C) cover has a white label. °Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approv- als apply for any paint manufacturer. Contact Viking for additional information. cULus Listed as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F103005 Rev 15.1 Page 4 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT N I I(I I16i® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Anoroval Requirements: • The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. CUSTO4 CL- Iclervificution of Custom Point Color: All custom color painted co/e( plates wilt have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint dot) of the paint on the label, Figure 1: Identification of Custom Paint Color for Concealed Covers Form No. F_103005 Rev 15.1 00 NOT PAINT 3-5/16" (84.1 Figure 2: Square Cover Assembly 15394 S r. Page 5 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT "J I KI NC* SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Mirage Standard Response Concealed Pendent Sprinkler VK462 er Plat~ FiNsh KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals' Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric2 Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1 Cover Plate Assembly Temperature Ratings4 Cover Plate Assembly Finishes5 Sprinkler Temperature Ratings W - 139 °F (59 °C) cover 135041, 136421 (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F (68 °C) or 153941 (square cover plate) Brass, Antique Brass, Brushed Brass, B -175°F (79 °C) and 200°F (93 °C) X - 165°F (74 °C) cover 135041, 136421 (large diameter), or Brushed Copper, Painted White, Painted 153941 (square cover plate) Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 Rev 15.1 0 I' Page 6 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT N4 I F(IFIGi SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com diameter opening 2-1/4' (57.2 mm) is required in the ceiling. 7\1 - Sprinkler and Adapter Assembly (Protective Cap is removed For installation--use Wrench 14031)K*) Sprinkler Frame Arms Sprinkler Wrench Flat Step 1: Carefully slide the wrench sideways around the deflector and pins. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench Flats. DO NOT apply more than 25 Ft. tbs. of torque. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond Finger tight. Sprinkler Wrench (Part No. 4047 is shown) A 1/2' ratchet s required (not ,ilab(e From Viking) NEVER install the sprinkler by applying the installation wrench across the Frame arms. DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. Figure 3: Sprinkler Installation and Correct Use of Wrenches NPT (15 mm _ 2- 2-9/16' 116 Minimum 77.777771 + II 1r1 2-3/4' (70 mm) or 3-5/16' (84,1 mm) Note: Upon sprinkler activation, the deflector descends to approximately 13/16' (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 Rev 15.1 (Added CCCF Approval)