Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 211; FPC2019-0022; PermitCARLSBAD, CA 92008-1208 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Print Date: 02/16/2022 Job Address: 2525 EL CAMINO REAL, #211, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $105,040.56 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2019-0022 Status: Closed - Finaled Applied: 02/06/2019 Issued: 02/21/2019 Finaled Close Out: 01/23/2020 Inspector: Final Inspection: PERMIT REPORT Lcity of Carlsbad Project Title: Description: BESHOCK RAMEN -21 HEAD SPRINKLER TI Applicant: FPContractor: ARROW AUTOMATIC FIRE SPRINKLER INC ARROW AUTOMATIC FIRE SPRINKLER INC HEATHER PAVLICK 9520 PATHWAY ST 9520 PATHWAY ST SANTEE, CA 92071-2518 SANTEE, CA 92071-4169 (619) 448-2518 (619) 448-2518 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Upright Pendent Vertical Sidewall Recessed Horizontal Sidewall Horizontal Sidewall % Concealed Pendent Riellablei Bulletin 014 Rev. K Model Fl FR Series Quick Response Standard Spray Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH *NSF Certified to NSF/ANSi Standard 61 Annex G UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1 FR56, F1 FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models El FR56, Fl FR56LL, Fl FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR56, Fl FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers El Conventional * Recessed Pendent/Fl/F2 .7 Recessed Pendent/FP lip XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 to appiy water to a tire mucn taster tnan standard sprinklers of the same tem- perature rating. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside aprecisely I IJ IUIdU1UIU Idb UdpUI. I uS JldbS XLH Recessed bulb is specially constructed to provide Pendent FP fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as theY liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 * Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be - exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. */ tie Deflector (XLH Only) Load Screw Washer Bulb Frame Cup O14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL1 K 5.6 Quick 1/2" NPT See See F1FR42 **F1FR42LL(l) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature 'Finish Table" F1FRXLH K2.8 Ratings" Table. F1FR28 Low Lead Sprinklers available only with Temperature Rating 200°F/93°c Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass **Low Lead Brass - or CDA Alloy 544 CDA Alloy 544 CDA_Alloy510 CDA Alloy 693 Tape 2. Model F1FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Sp 'SIN Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm))') 1/2" NPT (R112) 5.6 80 2.25" (57mm) 1,2,3,4 RA1414))(2X3X4) 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 RA1413 4 3/8" (10mm) 1/2" NPT(R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA1411 4 Conventional-Install in Upright or Pendent Position 15mm )') 1/2" NPT (R1/2) 5.6 1 80 1 57mm 3,4 RA1475 3 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (TefIon)* Plated - cULus listed Corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Sp (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2"(15mm)1 1/2' NPT(R1/2) 5.6 80 2.25" (57mm) [ 1,5 RA1415 7/16" (11mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) { 15 RA1410 cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. - Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler' Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2' (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) RA1413 3/8"(10mm) 1 1/2" NPT(R1/2) 2.8 40 2.25" (57mm) RA1411 Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler 1 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NFT(R½) 5.6 80 2.25" (57mm) RA1415 7/16(10mm) I 1/2" NFl (R1/2) j 4.2 60 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions — HUM—A I -I URScRddAW I Ma 'MU aWl MUm/rn aRm/CO Ma FACE OF Fm/SO 70 FACE OF COIJMC 0/ME/s7005 (_1 F/s,0RdMa - ATW.YJJAUMRECESS 172t4mm] L .i_____________________ AT MIS/MUM RECESS - J/RTR.sm,n1 VAT M&atVM RECESS -3/4770mm) AOJUSJMOU j I AT MIS/MUM RECESS - —1 I ¶ F' AT MUMMUM RECESS 7/8T22.2m") I/ar MM//MUM RECESS - -o/874;.s.,,mj AT MAX/MUM 050055 - 7-7/872&fin,m AT MW/MUM RECESS - 7-5/8747.3mm F12- REDUCER 2 5/8' 0/A. [65.7mm] HOLE IN CEILING 2 5/76' W. CUP FACE OF F/fl/NO TO FACE OF CEILING DIMENSION AT MAX/MUM RECESS -7/2738mm] AT MINIMUM RECESS / 725.4mm] AT /57 AT MAX/RUM RECESS MINIMUM RECESS = / '[25.4mm] 12 _ 5/78774.3mm] l/eO/A. AO.IUSTMENT ____________ [826am] Model F1 FR56, F1FR561-1-, F1FR42, F1FR42LL, F1FRXLH & Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 F1FR28FF Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: NominalKFactor J Sprinkler Nominal Thread Size Sprinkler Approval Identification Orifice US Metric Height Organizations Numbers(SIN) L_1/2"(15mm) 112"NPT(R1/2) 5.6 j 2.25"(57mm) 1,2,3 RA148521131 _80 15mm 1/2"NPT(R1/2) 5.6 I_80 1_2.25"(57mm) 3(1) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. () Electroless Nickel FIFE (Teflon®)* Plted - cULus listed corrosion Resistant Vertical Sidewall *DuPont Registered Trademark 4. Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Nominal Orifice Thread Size __________________ Height and Type of Approval Sprinkler Identification I US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 1 2.63(67mm) 1 1,2 1 1 RA14350(2X3) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant FACE OF FITTING To FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1725.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4779mm] AT MINIMUM RECESS = 3/879.5mm] 2 7/4" HOLE 0/A. [57.2mm] I X 1/2" REDUCER F 71 El ESCUTCHEON AT MAXIMUM RECESS = 1-3/8734.9mm H 7' AT MINIMUM RECESS = 2-1/16752.4mm] .7 • F2 ESCUTCHEON I AT MAXIMUM RECESS = 1-5/8741.3mm] AT MINIMUM RECESS = 2-7/16752.4mm] I [3.2mm] Horizontal Sidewall (i) 4-12' '5/76' DIA [I0I.6mm-304.8mm] 49.2mml 227/32 DIA CEILING TO ' [72,2mm] DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. El ESCUTCHEON 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT RECESSED HSW W/F1 OR F'2 ESCUTCHEON (1) FM APPROVED FOR 4' - 6" [701.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Note: 1-or Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FR escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover ½' (15mm) 5,6 80 1/2" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414 112" (15mm) 5.6 80 1/2" NPT F1 FR 1550 F/68°C 135°F157°C 100°F/381C I Red 1,4)1) RA1414 1/2" (15mm) 5.6 80 1/2" NPT F1 FR 1750 F/790C 1650F/74°C 100°F/380C Yellow 1 RA1414 1/2" (15mm) 5.6 80 1/2" NPT F1 FR 200°F/930C 165°F/740C 150°F/650C Green 1 RA1414 (11 For VdS only = 155°F/68°C Norbuib and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size I Model Temp. Rating Max. Ambient Bulb Color A Approvals pp Sprinkler Identification US I Metric Sprinkler I Cover Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT IF1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1,5 RA1414 *DuPont Registered Trademark 5. x 1/2" REDUCING TEE OR ELBOW —E1EHT 2 5/16" 0/A _FTIIiI CUP I CEILING7 1/2" MAX. I I -- COVER ADJUSTMENT COVER PLATE — ASSEMBLY - 3 5/16" 0/A SPRINKLER —2 5/8" 0/A. HOLE IN CEILING I 1/2" MAX. FACE OF FITTING _.._.._...TO FACE OF CEILING '1 DIMENSION 15/16" I' x 1/2" REDUCING TEE OR ELBOW 2 5/16" 0/A - CUP - 5/16" MAX. _i COVER ADJUSTMENT COVER PLATE— ASSEMBLY SPRINKLER 3 5116" 0/A. - 2 5/8" 0/A. HOLE IN CEILING 1 1/2' MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" CONCEALED, 1/2" ADJUSTMENT Hgure 1 Installation Aid A protective cap is included for use during installation. Important: The Fl FR56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight 1/2" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½" orifice, ½" NPT (R1/2), Model F1FR56 & Fl FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (930C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark CONCEALED, 5/16" ADJUSTMENT o,,, Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2 /8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model Fl FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color °C OF Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F(66°C) Green High 141 286 1 225°F (107°C) Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) SIN RA1435 - cULus permits use with Fl F2 or FP escutcheons for light hazard" only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate0 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (41(51(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover platet Electroless Nickel PTFE(Teflon0)*(7) Electroless Nickel PTFE (Teflona)* Bright Brass Bright Bras S(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Pain t(2)(6) Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull 111 Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(vSW), RA1425 (upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. () FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. 61LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. (7) cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark 7' Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices ' Paper Reliabl (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG, Printed in U.S.A. 04/14 P/N 9999970300 (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) Horizontal Sidewall / HB (See Fig. 7) ~ cl~ Recessed Fl Horizontal Sidewall (See Fig. 9) (See Fig. 5) Horizontal Sidewall (See Fig. 8) (See Fig. 1) (See Fig. 3) Bulletin 157 November 2018 liable Model F301156 Dry K5.6 (80 metric) Quick-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon Pendent with Model HB extended escutcheon Pendent with Model FP recessed escutcheon Pendent with Model Fl recessed escutcheon Concealed Pendent with Model CCP cover plate Horizontal Sidewall with Standard escutcheon Horizontal Sidewall with Model HB extended es- cutcheon Horizontal Sidewall with Model EP recessed es- cutcheon (FM Standard Response) Horizontal Sidewall with Model Fl recessed es- cutcheon (FM Standard Response) Available with 1" NPT, 1S07-1R1, 3/4 NPT, or 1S07- 1R3/4 inlet fitting. 3/4" NPT inlet fittings permit replacement of older 3/4" inlet dry sprinklers without changing to a larger sprin- kler fitting. Sprinklers, escutcheons, and cover plates are avail- able in a wide variety of standard and special appli- cation finishes. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. FM Approved for 175 psi (12 bar). Product Description Model F30R56 Dry sprinklers are quick-response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent or Dry Horizontal Sidewall configurations, Model F30R56 Dry sprinklers all use a 3 mm glass bulb operating element. See the Temperature Rat- ings table in this Bulletin for available temperature ratings. Model F30R56 Dry sprinklers are intended for installation on wet-pipe, dry-pipe, or preaction sprinkler systems in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F30R56 Dry sprinklers are available with a vari- ety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F30R56 Dry Pendent sprinklers are also available with the Model COP conical concealed cover plate as illustrated in Fig. 4. Avail- able sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model Fl escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F30R56 Dry sprinklers; the use of any other recessed escutcheon or cover plate with Model F30R56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Inlet fittings are available with 1" NPT, ISO 7-1R1, 3/4" NPT, See the Available Configurations, Listings, and Approvals or 1S07-1 R3/4 threads. Sprinklers with 3/4" NPT and 1S07- table in this Bulletin for further information on Model F30R56 1 R3/4 inlet fittings are intended primarily for replacement of Dry sprinklers. existing 3/4" or 1S07-1 R3/4 inlet dry sprinklers, but may also be used in new installations. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Length Listings and Inlet Identification Model Cover Plate (See Figs. 1-9) Approvals0 Threads Number (SIN) Standard 2" to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon cULus, NYC 3/4" NPT or Fl Recessed Escutcheon 3-1/2" to 36" 1S07-1R3/4 (90 to goq mm) FP Recessed Escutcheon F30R56 Dry CCP Cover Plate Pendent Standard 2" to 48" R5714 Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT Fl Recessed cULus, FM, NYC or Escutcheon 3-1/2" to 48" 1S07-1R1 (90 to 1200 mm) FP Recessed Escutcheon CCP_ Cover _Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus121, NYC(2) 3/4" NPT 3-1/2" to 48" or 1507-1R3/4 Fl Recessed Escutcheon (90 to 1200 mm) FP Recessed F30R56 Dry Horizontal Escutcheon . _________________ R5734 Sidewall Standard 2" to 48" Escutcheon (50 to 1200 mm) cULus121, FM 31, NYC(2) HB Extended 3-1/2" to 48" Escutcheon (90 to 1200 mm) 1" NPT or 1507-1R1 Fl Recessed Escutcheon 3-1/2" to 48" cULus(2), FP Recessed (90 to 1200 mm) FM13141, NYC(2) Escutcheon 1 For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. 2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (1) FM Approved for Light Hazard only. Model F30R56 Dry Horizontal Sidewall with Model Fl or Model FP recessed escutcheon are FM Approved as Standard Response. Installation Instructions Model F30R56 Dry sprinklers must only be installed in the following fittings: The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with 2. Patents Model F30R56 Dry series sprinklers may be covered by one or more of the following patents: US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) Certified by FM Approvals (FM) Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/p51112 (80 L/min/bar112) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F30R56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM See note below 175 psi (12 bar) F30R56 Dry Horizontal Sidewall cULus, NYC 4" to 6" 250 psi (17.2 bar) 4" to 12" __________________________ 175 psi (12 bar) FM See note below 175 psi (12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification necessary. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceil- ing Temperature Listings and Approvals111 Ordinary Orange 135°F (57°C) 135°F (57°C) 155°F (68°C) 100°F (38°c) cULus, FM, NYC Red Intermediate Yellow 175°F (79°C) 165°F (74°C) 150°F (66°C) cULus, NYC Intermediate Green 200°F (93°c) 165°F (74°c) 150°F (66°C) cULus, FM, NYC High Blue 286°F (141°C) None 225°F (107°C) cULus, FM(21, NYC 165°F (74°c) 150°F (66°C) cULus, NYC (11 For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. i21 High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes Component Sprinkler Escutcheon111 Cover Plate Standard Finishes Bronze Brass(') White Paint White Polyester(2) White Polyester Chrome Chrome Chrome Special Application Finishes Electroless Nickel PTFE2 Electroless Nickel PTFE Black Polyester Customer Color Polyester Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester (2) Custom Color Polyester iii Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model Fl escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized steel with no further finish. 121 cULus Listed as a Corrosion Resistant Sprinkler. (3) Brass finish available for standard, Model El, and Model FP escutcheons only. 3. I Model F301156 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) "A" Dim 2" to 48" (51 mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 2" to 36" (51mm to 914mmt in 1/4" (6mm increments for 3/4" connections System Fitting Inlet Fitting 2-1/8" "A" Dimension [54mm] Dia. 1-1/4" Hole in Ceiling [32 mm] Escutcheon Adjustment Sprinkler Can Escutcheon 15/32" 'Ceilingi [12mm] Nominal Escutcheon Position 1/4' [6 mm] Escutcheon Adjustment 1/4" [6 mm] Nominal Protrusion - 1-5/8" [41 mm] [76 mm] 153FG01—G DIA. Fig. 1 Note: The sprinkler can protrudes /4" when escutcheon is in nominal position. Escutcheon adjustment provides -¼" (-6mm) to +1114" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model 02 4. Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) "A" Dim 31,'2" to 48" (89mm to 1219mm) in 1/4' (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections F-:-----9 __ t ___ I fIF -System tee —Inlet fitting "A" Dimension 2-1/2" [64 mm] Dia. Hole in Ceiling 1/2" [13mm] Escutcheon Adjustment 'Ceiling T / 1-1/4" / f [32mm] Nomina( Position _/ I of Escutcheon 1/2" [13mm] ] Escutcheon Adjustment Escutcheon Spr-inkter Can 157FG02B 3-1/2" [89 mm] Escutcheon Dia. Fig. 2 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+ 12.7mm) "A" dimension adjustment range. Sprinkler Guard: Model 02 5. Model F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) "A" Dim 31/2' to 48(89mm to 1219mm) in 1/4(6mm) increments for 1" connections or 3'/2" to 36(89mm to 914mm1 in 1/4" (6mm1 increments for 3/4' connections -hull-- --..--- -- -h#li- 'Iii 11111 I '''I' L._lfl r-}-1-i i •'- L_IL__I_J System Tee '- Inlet Fitting 'A' Dimension Hole in Ceiling 1/4" [6 mm] Escutcheon Adjustment I I Sprinkler I VCup Escutcheon Ceiling 3/4" [19 mm] Nom. Nominal—" Escutcheon Position 1/4" [6 mm]] 37/32" Escutcheon Adjustment I [82 mm] Dia. - 153FG02-F Fig. 3 Note: Do not install the Model F30R56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. on I -Ii#iI 1111IQJ 11111 I rL__ i11J L.Jfl j'L. System Tee Inlet Fitting A Dimension Hole in Ceiling Model F301156 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) "A" Dim 31/2" to 48" (89mm to 1219mm) in 1/4' (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4' (6mmt incrAm'ints for I4" ronnpotioos Sprinkler Cup 3/16" [5 mm] Cover Plate Adjustment ) Ceiling ±1' Nominal Cover Plate Position 3/16" [5 mm] Cover Plate Adjustment 153FG03-F Fig. 4 Note: Do not install the Model F30R56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above, V Model CCP 1/2 Cover Plate Assembly !JPtI! Ii - i:I mm] h]. - 7' I Model F301156 Dry Pendent Sprinkler with Model Fl Recessed Escutcheon (SIN R5714) "A" Dim 31/2" to 48" (89mm to 1219mm) in 1/4(6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4' (6mm) increments for 3/4" connections. F=-r--F=\ II') •.....1 :1: System Tee Inlet Fitting 2-1/4° [57 mm] Dia. Hole in Ceiling A Dimension Collar 1/4 [6 mm] Escutcheon Adjustment I Nominal Escutcheon J Position 1/4 [6 mm] Escutcheon Adjustment 1/8 LCeiling mm] _ Es cutcheon I 227/32 [72 mm] Dia. 157F305B Fig. 5 91 Model F301156 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) "A" Dim 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 2" to 36" (51 mm 10914mm) in 1/4" (6mm) increments for 3/4" connections Ceiling j 4" [102 mm] Mm. 12" [305 mm] Max. Sprinkler Can - 15/32" [12mm] 2-3/32" I - System Fitting Inlet Fitting - [53 mm] 5/8'] [16 mm] 3" [76 mm] 2-1/8" [54 mm] Dia. - L 1/4" [6mm] Nomin al Protrusion Hole in Wall I 1/4"]6mm] Escutcheon Adjustment 1-1/4'[32 mm] ____________ Nominal Escutcheon Position u Escutcheon Adjustment 157FG06B __________ "A" Dimension Fig. 6 Note: The sprinkler can protrudes ¼" when escutcheon is in nominal position. Escutcheon adjustment provides 1/4" (-6mm) to +1114" (+32mm) "A" dimension adjustment range. Model 17301156 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) "A" Dim 372' to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 9 14mm) in 1/4(6mm) increments for 3/4" connections Ceiling Ca I 4,7 [102mm] Mm. Escutcheon 12" [305mm] Max. i— Sprinkler Can I I System Tee 23/32" I Inlet Fitting m]H 5/8" [16mm] - L f 3-1/2" [89mm] Esc - H utcheon Dia. 2 1/2" Dia [64mm] - 1-1/4" 1-1/4" [32mm] Nominal Protrusion Hole in Wall [32mm] 1/2" [13mm] Escutcheon Adjustment 157F007B 1/2" [13mm] Nominal Position Escutcheon of Escutcheon Adjustment - "A" Dimension Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/2" (-1 27mm) to +1/2" (+ 12.7mm) "A" dimension adjustment range. 10. I Model F301156 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) I "A" Dim 3/2 to 48" (89mm to 1219mm) in 1/4 (6mm) increments for 1" connections or 3½" to 36" (89mm to 914mm) in 1/4"(6mm) increments for 3/4" connections System Tee Az. ' Escutcheon Sprinkler Cup Inlet Fitting 2-1/2' J- (64 mm) Dia. Hole in Wall L Ceiling Nom. 1-1/4" [32 mm] 4" [102 mm] Mm. cULus, NYC: 6' [152 mm[ Max. FM: 12" [305 mm) Max. H 5/8" [16 mm] 3-7/32" [82 mm] Dia. 157FG08B 1/4" [6 mm] Escutcheon Adjustment "A" Dimension - 1/4" [6 mm] Escutcheon Adjustment Nominal Escutcheon Position M. Note: Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. ill Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model Fl Recessed Escutcheon (SIN R5734) "A" Dim 31/2' to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections Escutcheon Collar -. System Tee \- Inlet Fitting -- , I, Nom. 1-3/4' I 1/8" [44 mm] I [3 mm] 4"[10, mm] Mm. = cULus, NYC: 6' [152 mm] Max. Cq FM: 12" [305 mm] Max. 5/8(16mm) 2-27/32" [72 mm] Dia. 2-1/4" [57 mm] Dia. Hole in Wall 1/4' [6 mm] Escutcheon Adjustment I Nominal Position 157FG09B 1/4' [6 mm] of Escutcheon Escutcheon Adjustment "A" Dimension Fig. 9 12. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM (DRY PENDENT SPRINKLER NTH STANDARD ESCUTCHEON SHOWN) AMBIENT TEMpop1TEEXPOSED TO DISCHARGE END OF EXPOSED BARREL AMBIENT TEMPERATURE 40Y/4 I 50'F/I0'C I DOSED MINIMUM BARREL IM OF FITTING 10 TOP OF CEIUNG)SSS IN. (MU) IN. (MM) IN. (MM) 40F(4) 0 0 0 30(-1C) 0 0 0 20r (-70) 4 (100) 0 0 bc (—lrc) 8 (200) 1(25) 0 OF (-I8C) 12 (300) 3 (75) 0 -lOF (-23C) 14 (350) 4 (100) 1 I (25) -20F (-2WC) 14 (350) 6 (150) 3 (75) -307 (-Mv) lB (400) 8 (200) 4 (lao) -40Y (-400) lB (450) 8 (200) 4 (100) -soc (-460) 20 (500) 10 (250) 6 (150) -BOc (-SIC) 20 (500) 10 (250) 6 (150) WET IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER CONSIDER WRAPPING THE EXPOSED BARREl. WITH INSULATiON, FOAM INSULATING N MINIMUM (HEA ) TAPE OR EQUIVALENT. EXPOSED SEA1. AROUND THE SPRINKLER 10 AVOID LENGTH NE CLEARANCE SPACE BARREL LEAKAGE OF AIR INTO TilE PROTECTED AREA AND CONSEQUENT FORMATION OF / CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERA1TON. SEE BELOW FOR / A CLEARANCE DIMDI ON HOLE RE METHODS FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES USIED, USE THE NEXT COOLER TEMPERATURE. WALTi THE MINIMUM EXPOSED BARREl. LENGTH 15 NOT THE SAME AS THE A DIMENSON. THE MINIMUM EXPOSED BARREl. LENGTH IS BASED ON A PROPERLY SEALED PENETRATION RIN A MAXIMUM RIND VELOCITY PH THE EXPOSED SPRINKLER OF CIDUNO ..J' 30 MPH (48 KM/Il). LONGER EXPOSED BARREl. LENGThS RIU. HELP A....D . .........NO OF THE WET PIPING WHERE HIDIO1 ESCUTCHEON RIND VELOCITY IS EXPECTED. — THE MINIMUM EXPOSED BARREl.. LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE (PROTECTED AREA) DISCHARGE DID OF SPRINKLER WALL FOR DRY HORIZONTAL SIDEWALL SPRINKLERS. RECOMMENDED EXPOSED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO DRY HORIZONTAL SIDEWALL SPRINKLERS RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (DRY SPRINKLER WET PIPE WiTh STANDARD ESCUTCHEON SHOWN) WErPIPE iLl.' (HE AREA) (HEATED AREA) _JJ.' I MINIMUM EXPOSED I I —L I I MINIMUM BARREL I 1 I EXPOSED I BA. LENGTH (SEE Asovo OCOCiTTE FLASHING RASOO, 04003910 INSIDE FACE [SEAL (SEE ABOVE) I I HOLIE -1-.•••••••••CLEARANCE INIDJLA1Th FREE, Ull F OR COOLER STRUCTURE OR EXTERIOR FRAMING DRY SPRINKLER DRY SPRINKLER I (PROTECTED AREA) DISCHARGE DID OF (PROTECTED AREA) DISCHARGE DID OF I IN COLD AREA IN COLD AREA I -- I57FG100 Fig. 10 13. *CAUTION* RELIABLE DRY PENDENT AND DRY HORIZONTAL SIDEWALL SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damag the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet-pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal Obstruction Obstruction Female ____ Female ___ Pipe Pipe Thread-' Thread_-' I CPVC itting - CPVC Fitting with Internal Obstruction No Internal Obstruction Shorter Longer Inlet Inlet Male Male Pipe Pipe Thread/H Thread/' HH DrySprinkler DrySprinkler ShortInlet("PL") StandardInlet BESURETOORDERTHECORRECTSPRINKLERSFORYOUR APPLICATION O1GFGOSC Fig. 11 14. ,ij 15. ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS 023000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 0161910 1531g16 15 71 g16 PPEAAANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL MATERIAL SPECIFICATIONS Fig. 12 16. the side outlet plugged (wet-pipe systems only) Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet-pipe systems only) (gasket sealed outlets shall not be used) Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 11 and upon verification that the CPVC adapter or tee does not interfere with the sprin- klers inlet (wet-pipe systems only) (gasket sealed outlets shall not be used) Model F30R56 Dry sprinklers must not be installed into el- bows, welded outlets, or gasket sealed outlets. Installation of the Model F30R56 Dry sprinkler is not recommend in cop- per pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry-pipe system installations, the Model F30R56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 9 in this Bulletin. Do not install Model F30R56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal obstruc- tion (see Fig. 11); this will damage the sprinkler, the fitting, or both. Model F30R56 Dry sprinklers are available with a short "PL" inlet fitting for installation on CPVC fittings of wet- pipe sprinkler systems only. Model F30R56 Dry sprinklers connected to wet-pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 10 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service, Sprinklers with 3/4" NPT and 1507-1R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3 and F3R wrenches are designed to be in- serted into the groves in the sprinkler's wrench boss as shown in Fig. 12. The Model XL02 wrench is de- signed to fit into the cup and engage the wrench boss as shown in Fig. 13. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or removing the wrench from the sprinkler, care should be taken to prevent damage to the sprin- kler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22 - 30 lb- ft (30-40 N-m) for 1" NPT and 1S07-1R1 sprinklers, and 14- 20 lb-ft (19-27 N-m) for 3/4" NPT and 1S07- 1R3/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F30R56 Dry sprinkler may be installed using a pipe wrench. The pipe wrench shall only be permitted to inter- face with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 16). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 - 40 N-m) for 1" NPT and 1507-1 Ri sprinklers, and 14-20 lb-ft (19-27 N-m) for 3/4" NPT and IS07-1R3/4 sprinklers. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model Fl escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in .a counter-clockwise direc.- tion. To install the Model COP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. Remove the orange protective clip when placing the sprinkler system in service. 17, Installation Data Sprinkler Suggested Hole Diameter Required Centerline of Sprinkler Installation Model Escutcheon or Cover Plate in Wall or Ceiling Tube/Inlet to Finished Ceiling Wrench Vertical Dimension* Standard Escutcheon 2-1/8" (54 mm) F3 or F3R HR Extended Escutcheon 2-1/2" (64 mm) F3QR56 Dry Pendent Not Applicable Fl Recessed Escutcheon 2-1/4" (57 mm) FP Recessed Escutcheon XL02 2-1/2" (64 mm) COP Cover Plate Standard Escutcheon 2-1/8" (54 mm) 4-5/8" to 12-5/8" (118 mm to 321 mm) F3 or F38 HB Extended Escutcheon 2-1/2" (64 mm) F3QR56 Dry Fl Recessed Escutcheon 2-1/4" (57 mm) cULus, NYC FP Recessed Escutcheon 2-1/2" (64 mm) Horizontal 4-5/8" to 6-5/8" to 168 (1118 mm mm) Sidewall Fl Recessed Escutcheon 2-1/4" (57 mm) FM XL02 FP Recessed Escutcheon 2-1/2" (64 mm) 4-5/8" to 12-5/8" (118 mm to 321 mm) * Based on 5/8" (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F30R56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids: Remove dust by us- ing a soft brush or gently vacuuming. Replace any sprin- kler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or op- erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: Sprinkler: [Model F30R56 Dry Pendent SIN R5714] [Model F30R56 Dry Horizontal Sidewall SIN R5734] Escutcheon/Cover Plate: [None][Standard escutch- eon][Model HB extended escutcheon][Model Fl re- cessed escutcheon][Model FP recessed escutcheon] [Model CCP cover plate - pendent only] Inlet Threads: [1" NPT]{IS07-1R1][3/4" NPT][IS07- 1R314] Inlet Fitting: [Long - Standard Inlet Fitting][Short "PL" - Wet Pipe Systems only] Sprinkler Temperature Rating: See Temperature Rat- ings table Sprinkler Finish: See Finishes Table Escutcheon/Cover Plate Finish: See Finishes Table Length: "A" Dimension (face of tee to face of ceiling or wall) in ¼" (6 mm) increments - See Fig. 1 through Fig. 9 Note: The "A" dimension is based on a nominally gauged pipe thread "make-up" of .600" (15mm) per ANSI B2.1 [approxi- mately 7 1/2 threads]. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years,. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled Reliabi ® (800) 431-1588 Sales Offices Paper (914) 829-2042 Corporate Offices e (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/18 P/N 9999970175