Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 222; FPC2017-0221; PermitCARLSBAD, CA 92008-1208 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Print Date: 02/16/2022 Job Address: 2525 EL CAMINO REAL, #222, Permit Type: FIRE-Construction Commercial Parcel #: 1563020900 Valuation: $455,518.94 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2017-0221 Status: Closed - Finaled Applied: 08/08/2017 Issued: 08/29/2017 Finaled Close Out: 02/10/2021 Inspector: Final Inspection: PERMIT REPORT (ity of Carlsbad Project Title: Description: VICTORIA'S SECRET -SPRINKLER TI >100 HEADS (142) FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 341-7780 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE NFPA 13 or 13R System> 100 heads $634.00 Total Fees: $766.00 Total Payments To Date: $766.00 "Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov ft2c20r1- c HYDRAULIC CALCULATIONS for Job Information Project Name: VICTORIA'S SECRET Contract No. : 600024401 City: CARLSBAD, CA 92008 Project Location: 2525 EL CAMINO REAL, SUITE #222 Date: 7/28/2017 - Contractor Information - Name of Contractor: SIMPLEX GRINNELL Address: 3568 RUFFIN ROAD SOUTH City: SAN DIEGO, CA 92123 Phone Number: 858-633-9125 E-mail: maenglishQsimplexgrinnell.com Name of Designer: M. ENGLISH Authority Having Jurisdiction: City of Carlsbad Fire Prevention Bureau Design Remote Area Name 1 Remote Area Location Retail Area Occupancy Classification Ordinary Hazard 2 Density (gpm/ft2) 0.2 Area of Application (ft2) 1500 Coverage per Sprinkler (ft2) 130 Number of Calculated Sprinklers 20 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 250 Total Water Required (incl. Hose Streams) (gpm) k793.7 Required Pressure at Source (psi) 54.2 Type of System Wet Volume - Entire System (gal) 1069.1 gal Water Supply Information Date 4/5/2017 Location HYDRANT H60994 Source SRC Notes 0.20/1500 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Sprmnkler\FP Victorias Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 1 Job: VICTORIA'S SECRET Node Labels: Off Pipe Labels: Off Diagram for Design Area: I (Ootimized Hydraulic SimoIified File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victorias Secret TSAC 600024401\Sprinkler\FP Victorias Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job ': VICTORIA'S SECRET Hydraulic Analysis for: I Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb.s/ft2) Water Supply Parameters Supply 1: SRC Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 92 6050 42 Static Pressure I Residual I I Flow I Available I I I Total Demand I Required Pressure Node at Source (psi) I I Pressure I I (gpm) I I Pressure I I (gpm) I I (psi) (psi) (psi) I SRC 92 42 6050 91.4 793.7 54.2 Hoses Inside Hose Flow/ Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) 250 Other (custom defined) Hose Flow (gpm) ------------------------------------------------------------------------------------ Total Hose Flow (gpm) 250 Sprinklers Ovehead Sprinkler Flow (gpm) 543.7 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 ------------------------------------------------------------------------------------ Total Sprinkler Flow (gpm) 543.7 Other Required Margin of Safety (%) 10 BOR-1 - Pressure (psi)' 50.7 BOR-1 -Flow (gpm) 543.7' Demand w/o System Pump(s) N/A File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victorias Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 3 C) 0 CD —1 C)) > C) a-' Pressure, psi • ./ .I.. I! Cn IL CD . /1 • 1 / . - . I I I . . 0 CD 3 0. CL CD Job: VICTORIA'S SECRET Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 -Static 0 92 S2 Supply point #2 - Residual 6050 42 Di Elevation Pressure 0 6.1 D2 System Demand 543.7 54.2 D3 System Demand + Add.Out.Hose 793.7 54.2 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 91 739.2 36.7 . 793.7 Supply; Safety Pressure 82 695.8 27.6 793.7 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/z) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) Si Overhead 130 5.6 0.2 26 21.6 0.206 26.7 22.8 Sprinkler S1O Overhead 130 5.6 0.2 26 21.6 0.206 26.8 22.8 Sprinkler Overhead 130 5.6 0.2 26 21.6 0.208 27.1 23.4 Sprinkler S12 Overhead 130 5.6 0.2 26 21.6 0.212 27.6 24.2 Sprinkler S13 Overhead 130 5.6 0.2 26 21.6 0.211 27.4 24 Sprinkler 514 Overhead 130 5.6 0.2 26 21.6 0.211 27.4 23.9 Sprinkler S1S Overhead 130 5.6 0.2 26 21.6 0.211 27.5 24.1 Sprinkler S16 Overhead 130 5.6 0.2 26 21.6 0.21 27.3 23.8 Sprinkler S17 Overhead 130 5.6 0.2 26 21.6 0.211 27.5 24.1 Sprinkler S18 Overhead 130 5.6 0.2 26 21.6 0.214 27.9 24.8 Sprinkler S19 Overhead 130 5.6 0.2 26 21.6 0.213 27.7 24.5 Sprinkler S2 Overhead 130 5.6 0.2 26 21.6 0.204 26.5 22.4 Sprinkler File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 S20 Overhead 130 5.6 0.2 26 21.6 0.213 27.7 24.5 Sprinkler S3 Overhead 130 5.6 0.2 26 21.6 0.205 26.7 22.8 Sprinkler S4 Overhead 130 5.6 0.2 26 21.6 0.208 27 23.3 Sprinkler S5 Overhead 130 5.6 0.2 26 21.6 0.211 27.4 23.9 Sprinkler S6 Overhead 130 5.6 0.2 26 21.6 0.211 27.5 24 Sprinkler S7 Overhead 130 5.6 0.2 26 21.6 0.211 27.4 24 Sprinkler S8 Overhead 130 5.6 0.2 26 21.6 0.2 26 21.6 Sprinkler Overhead 130 5.6 0.2 26 21.6 0.205 26.6 22.6 Sprinkler File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job: VICTORIA'S SECRET Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pies. Req. Discharge gpm/p5i1/2 gpm ft2 psi psi ft gpm gpm/ft2 psi gpm S8 Overhead Sprinkler 5.6 26 130 21.6 21.6 8.25 HEAD Open 0 0.2 -4.9 26 S2 Overhead Sprinkler 5.6 26.5 130 22.4 21.6 11 HEAD Open 0.5 0.204 -6.1 26 S9 Overhead Sprinkler 5.6 26.6 130 22.6 21.6 11 HEAD Open 0.6 0.205 -6.1 26 S3 Overhead Sprinkler 5.6 26.7 130 22.8 21.6 11 HEAD Open 0.7 0.205 -6.1 26 Si Overhead Sprinkler 5.6 26.7 130 22.8 21.6 8.25 HEAD Open 0.7 0.206 -4.9 26 S1O Overhead Sprinkler 5.6 26.8 130 22.8 21.6 11 HEAD Open 0.8 0.206 -6.1 26 S4 Overhead Sprinkler 5.6 27 130 23.3 21.6 11 HEAD Open 1 0.208 -6.1. 26 Sli Overhead Sprinkler 5.6 27.1 130 23.4 21.6 11 HEAD Open 1.1 0.208 -6.1 26 S16 Overhead Sprinkler 5.6 27.3 130 23.8 21.6 11 HEAD Open 1.3 0.21 -6.1 26 S5 Overhead Sprinkler 5.6 27.4 130 23.9 21.6 11 HEAD Open 1.4 0.211 -6.1 26 S14 Overhead Sprinkler 5.6 27.4 130 23.9 21.6 11 HEAD Open 1.4 0.211 -6.1 26 S7 Overhead Sprinkler 5.6 27.4 130 24 21.6 11 HEAD Open 1.4 0.211 -6.1 26 S13 Overhead Sprinkler 5.6 27.4 130 24 21.6 11 HEAD Open 1.4 0.211 -6.1 26 S6 Overhead Sprinkler 5.6 27.5 130 24 21.6 11 HEAD Open 1.5 0.211 -6.1 26 S15 Overhead Sprinkler 5.6 27.5 130 24.1 21.6 11 HEAD Open 1.5 0.211 -6.1 26 S17 Overhead Sprinkler 5.6 27.5 130 24.1 21.6 11 HEAD Open 1.5 0.211 -6.1 26 S12 Overhead Sprinkler 5.6 27.6 130 24.2 21.6 11 HEAD Open 1.6 0.212 -6.1 26 S20 Overhead Sprinkler 5.6 27.7 130 24.5 21.6 11 HEAD Open 1.7 0.213 -6.1 26 519 Overhead Sprinkler 5.6 27.7 130 24.5 21.6 11 HEAD Open 1.7 0.213 -6.1 26 S18 Overhead Sprinkler 5.6 27.9 130 24.8 21.6 11 HEAD Open 1.9 0.214 -6.1 26 521 Node 23.1 15.67 NODE -8.1 519 Node 23.2 15.67 NODE -8.1 538 Node 23.3 15.67 NODE -8.1 537 Node 23.3 15.67 NODE -8.1 518 Node 1 23.4 1 -8.1 15.67 NODE File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401 \Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 Job: VICTORIA'S SECRET Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/p5i½ gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 536 Node 23.6 15.67 NODE -8.1 517 Node 24 15.67 NODE -8.1 535 Node 24.2 15.67 NODE -8.1 530 Node 24.8 15.67 NODE -8.1 555 Node 24.8 15.67 NODE -8.1 529 Node 24.9 15.67 NODE -8.1 554 Node 24.9 15.67 NODE -8.1 548 Node 24.9 15.67 NODE -8.1 547 Node 25 15.67 NODE -8.1 528 Node 25.1 15.67 NODE -8.1 553 Node 25.2 15.67 NODE -8.1 546 Node 25.3 15.67 NODE -8.1 002 Node 25.3 15.67 NODE -8.1 006 Node 25.4 15.67 NODE -8.1 007 Node 25.7 15.67 NODE -8.1 515 Node 25.9 15.67 NODE -8.1 514 Node 25.9 15.67 NODE -8.1 513 Node 26 15.67 NODE -8.1 512 Node 26 15.67 NODE -8.1 511 Node 26.3 15.67 NODE -8.1 008 Node 26.4 15.67 NODE -8.1 013 Node 31.2 15.67 NODE -8.1 019 Node 44.5 -3 NODE 0 050 Node 44.6 2 NODE -2.2 031 Node 45.1 -3 NODE 0 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copynght © 2002-2012 Tyco Fire Protection Products Page 8 Job: VICTORIA'S SECRET Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psll/2 gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 047 Node 46.5 -3 NODE 0 048 Node 46.5 -3 NODE 0 049 Node 46.7 -3 NODE 0 039-0 Node 49.5 -11.67 NODE 3.8 039-I Node 50.2 -12.83 NODE 4.3 BOR-O Node 50.5 -13.56 NODE 4.6 BOR-I Node 50.7 -14 NODE 4.8 051-I Node 52 2 NODE -2.2 053 Node 54.1 -3 NODE 0 SRC Supply -543.7 54.2 -3 SUPPLY . 0 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Sprinkler\FP Victonas Secret TSACdwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 9 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/ps11/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I S8 8.25 5.6 26 1 2x(us.Tee-Br)=10 11.54 120 21.6 538 15.67 26 1.049 lx(us.90)=2 12 0.2108 -3.2 23.54 5 538 15.67 0 2 1.91 120 23.3 537 15.67 26 2.067 0 0.0078 0 1.91 0.0 537 15.67 26.6 2 8.92 120 23.3 536 15.67 52.6 2.067 0 0.0286 0 8.92 0.3 536 15.67 26.8 2 9.5 120 23.6 535 15.67 79.4 2.067 0 0.0613 0 9.5 0.6 535 15.67 27.1 2 lx(us.Tee-Br)=10 7.05 120 24.2 513 15.67 106.5 2.067 10 0.1055 0 17.05 1.8 513 15.67 189.2 4 2 120 26 512 15.67 295.7 4.26 0 0.0207 0 2 0.0 512 15.67 82.4 4 10 120 26 511 15.67 378.1 4.26 0 0.0326 0 10 0.3 511 15.67 82.3 4 2.12 120 26.3 008 15.67 460.4 4.26 0 0.0469 0 2.12 0.1 008 15.67 83.3 4 lx(us.Tee-Br)=26.33 22.38 120 26.4 013 15.67 543.7 4.26 2x(us.90)=26.33 52.67 0.0638 0 75.05 4.8 013 15.67 0 5 lx(us.Tee-Br)=25 100.54 120 31.2 019 -3 543.7 5.047 5x(us.90)=60 85 0.028 8.1 185.54 5.2 019 -3 0 6 1x(coupling)=1 54.57 120 44.5 031 -3 543.7 6.065 1 0.0114 0 55.57 0.6 031 -3 0 8 lx(coupling)=2.33 108.17 120 45.1 039-0 -11.67 543.7 8.329 7x(us.90)=146.87 149.2 0.0024 3.8 257.36 0.6 039-0 -11.67 0 8 1.17 0 49.5 AV-1 Check 039-1 -12.83 543.7 0 0 0.1282 0.5 1.17 0.1 039-I -12.83 0 8 1x(couplirig)=2.33 0.73 120 50.2 BOR-0 -13.56 543.7 8.329 2.33 0.0024 0.3 3.06 0 BOR-O -13.56 0 8 0.44 0 50.5 BR/-N BOR-I -14 543.7 0 0 0.0532 0.2 *** 0.44 0.0 BOR-I -14 0 8 lx(coupling)=2.33 106.1 120 50.7 047 -3 543.7 8.329 4x(us.90)=83.92 127.05 0.0024 -4.8 1x(us.Tee-Br)=40.8 233.15 0.6 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victorias Secret TSAC 600024401\Sprinkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 10 Job VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 047 -3 0 8 lx(coupling)=3.52 6.83 140 46.5 048 -3 543.7 8.55 3.52 0.0016 0 10.36 0.0 048 -3 0 8 lx(us.90)=25.42 51.67 150 46.5 049 -3 543.7 7.961 25.42 0.002 0 77.08 0.2 049 -3 0 8 lx(us.90)=31.7 5 140 46.7 050 2 543.7 8.55 31.7 0.0016 -2.2 36.7 0.1 050 2 0 8 6.42 0 44.6 Wilkins350AD 051-1 2 543.7 0 0 1.1515 0 A 6.42 7.4 051-I 2 0 8 lx(elbow.22.5)=7.93 5 140 52 053 -3 543.7 8.55 7.93 0.0016 2.2 12.93 0.0 053 -3 0 8 10 150 54.1 SRC -3 543.7 7.961 0 0.002 0 10 0.0 SRC 54.2 Path No: 2 S2 11 5.6 26.5 1 lx(us.Tee-Br)=5 5.92 120 22.4 519 15.67 26.5 1.049 lx(us.90)=2 7 0.2182 -2 12.92 2.8 519 15.67 26.7 2 8.92 120 23.2 518 15.67 53.2 2.067 0 0.0292 0 8.92 0.3 518 15.67 26.7 2 8.92 120 23.4 517 15.67 79.9 2.067 0 0.0621 0 -8.92 0.6 517 15.67 27 2 lx(us.Tee-Br)=10 7.64 120 24 515 15.67 106.9 2067 10 0.1064 0 17.64 1.9 515 15.67 0 4 1.75 120 25.9 514 15.67 106.9 4.26 0 0.0031 0 1.75 0 514 15.67 82.3 4 9.86 120 25.9 513 15.67 189.2 4.26 0 0.009 0 9.86 0.1 513 26 Path No: 3 S9 11 5.6 26.6 1 1x(us.Tee-Br)=5 5.42 120 22.6 537 15.67 26.6 1.049 lx(us.90)=2 7 0.2203 -2 12.42 2.7 537 23.3 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victorias Secret TSAC 600024401\Sprinkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 11 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Path No: 4 S3 11 5.6 26.7 1 lx(us.Tee-Br)=5 5.17 120 22.8 518 15.67 26.7 1.049 lx(us.90)=2 7 0.2216 -2 12.17 2.7 518 23.4 Path No: 5 Si 8.25 5.6 26.7 1 lx(us.Tee-Br)=5 9.03 120 22.8 521 15.67 26.7 1.049 lx(us.90)=2 7 0.2221 -3.2 16.03 3.6 521 15.67 0 2 2.55 120 23.1 519 15.67 26.7 2.067 0 0.0082 0 2.55 0.0 519 23.2 Path No: 6 S10 11 5.6 26.8 1 1x(us.Tee-Br)=5 5.42 120 22.8 536 15.67 26.8 1.049 lx(us.90)=2 7 0.2224 -2 12.42 2.8 536 23.6 Path No: 7 S4 11 5.6 27 1 lx(us.Tee-Br)=5 5.17 120 23.3 517 15.67 27 1.049 lx(us.90)=2 7 0.2261 -2 12.17 2.8 517 24 Path No: 8 Sli 11 5.6 27.1 1 lx(us.Tee-Br)=5 5.42 120 23.4 535 15.67 27.1 1.049 lx(us.90)=2 7 0.2271 -2 12.42 2.8 535 24.2 Path No: 9 S16 11 5.6 27.3 1 ix(us.Tee-Br)=5 6.28 120 23.8 554 15.67 27.3 1.049 lx(us.90)=2 7 0.2314 -2 13.28 3.1 554 15.67 27.5 2 8.92 120 24.9 553 15.67 54.8 2.067 0 0.0309 0 8.92 0.3 553 15.67 27.5 2 lx(us.Tee-Br)=10 7.64 120 25.2 511 15.67 82.3 2.067 10 0.0655 0 17.64 1.2 511 26.3 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victorias Secret TSAC 600024401\Sprinkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 12 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 10 S5 11 5.6 27.4 1 lx(us.Tee-Br)=5 6.92 120 23.9 528 15.67 27.4 1.049 lx(us.90)=2 7 0.2321 -2 13.92 3.2 528 15.67 54.9 2 lx(us.Tee-Br)=10 1.28 120 25.1 514 15.67 82.3 2.067 10 0.0654 0 11.281 1 0.7 514 25.9 Path No: 11 S14 11 5.6 27.4 1 lx(us.Tee-Br)=5 5.92 120 23.9 548 15.67 27.4 1.049 lx(us.90)=2 7 0.2321 -2 12.92 3 548 15.67 0 2 9.5 120 24.9 547 15.67 27.4 2.067 0 0.0085 0 9.5 0.1 547 15.67 27.4 2 8.92 120 25 546 15.67 54.8 2.067 0 0.0309 0 8.92 0.3 546 15.67 27.6 2 lx(us.Tee-Br)=10 1.28 120 25.3 512 15.67 82.4 2.067 10 0.0656 0 11.28 0.7 512 26 Path No: 12 S7 11 5.6 27.4 1 lx(us.Tee-Br)=5 5.17 120 24 530 15.67 27.4 1.049 lx(us.90)=2 7 0.2327 -2 12.17 2.8 530 15.67 0 2 6.89 120 24.8 529 15.67 27.4 2.067 0 0.0086 0 6.89 0.1 529 15.67 27.5 2 8.92 120 24.9 528 15.67 54.9 2.067 0 0.0309 0 8.92 0.3 528 25.1 Path No: 13 S13 11 5.6 27.4 1 lx(us.Tee-Br)=5 5.92 120 24 547 15.67 27.4 1.049 lx(us.90)=2 7 0.2328 -2 12.92 3 547 25 Path No: 14 S6 11 5.6 27.5 1 lx(us.Tee-Br)=5 5.17 120 24 529 15.67 27.5 1.049 lx(us.90)=2 7 0.2332 -2 12.17 2.8 529 24.9 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 13 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 El.ev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 15 S15 11 5.6 27.5 1 lx(us.Tee-Br)=5 4.8 120 24.1 555 15.67 27.5 1.049 lx(us.90)=2 7 0.2336 -2 11.8 2.8 555 15.67 0 2 8.92 120 24.8 554 15.67 27.5 2.067 0 0.0086 0 8.921 0.1 554 24.9 Path No: 16 S17 11 5.6 27.5 1 lx(us.Tee-Br)=5 6.28 120 24.1 553 15.67 27.5 1.049 lx(us.90)=2 7 0.2336 -2 13.28 3.1 553 25.2 Path No: 17 S12 11 5.6 27.6 1 1x(us.Tee-Br)=5 5.92 120 24.2 546 15.67 27.6 1.049 lx(us.90)=2 7 0.235 -2 12.92 3 546 25.3 Path No: 18 S20 11 5.6 27,7 1 lx(us.Tee-Br)=5 5.17 120 24.5 002 15.67 27.7 1.049 lx(us.90)=2 7 0.237 -2 12.17 2.9 002 15.67 0 2 6.89 120 25.3 006 15.67 27.7 2.067 0 0.0087 0 6.89 0.1 006 15.67 27.7 2 8.92 120 25.4 007 15.67 55.4 2.067 0 0.0315 0 8.92 0.3 007 15.67 27.9 2 1x(us.Tee-Br)=10 1.28 120 25.7 008 15.67 83.3 2.067 10 0.067 0 11.281 1 0.8 008 26.4 Path No: 19 S19 11 5.6 27.7 1 lx(us.Tee-Br)=5 5.17 120 24.5 006 15.67 27.7 1.049 lx(us.90)=2 7 0.2375 -2 12.17 2.9 006 25.4 Path No: 20 S18 11 5.6 27.9 1 lx(us.Tee-Br)=5 5.17 120 24.8 007 15.67 27.9 1.049 lx(us.90)=2 7 0.2397 -2 12.17 2.9 007 25.7 File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER'tVictonas Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 14 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (P1) (ft) (gpm/p5i½) (gpm) (in) (ft) (ft) (psi) (psi) Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 12.24 ft/s occurs in the following pipe(s): (013-008) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401 \Sprinkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 15 p Job VICTORIA'S SECRET Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: SRC; Supply Name:SRC e 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 cc ci o ci 0 ci 0 ci 0 ci 0 ci ci ci ci Flow, gpm Pressure Loss Function Design Area: 1; BFP Ref.: 709 (WiIkins350ADA, Size = 8); Inlet Node: 051-I; Outlet Node: 050 0 ici ci ci 0 O ci 0 00 0 0 ci - ci ci r- cc o ci ci t 0 Flow, gpm File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victorias Secret TSAC 600024401 \Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 16 Job: VICTORIA'S SECRET Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 707 (BFV-N, Size = 8); Inlet Node: BOR-I; Outlet Node: BOR-O 5' 0' 05 05 05 05 05 05 05 05 N 0'. 05 05 05 05 05 05 05 05 Flow, gpm Pressure Loss Function Design Area: 1; Valve Ref.: 708 (AV-1 Check, Size = 8); Inlet Node: 039-I; Outlet Node: 039-0 2.085 0.585 0.085 0 0 0 0 O N 0 OS N 0 Flow, gpm File: C:\Users\maenglish\Box Sync\480 - San Diego\The Shoppes at Carlsbad - MASTER\Victonas Secret TSAC 600024401\Spnnkler\FP Victonas Secret TSAC.dwg Date 7/31/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 17 HYDRAULIC CALCULATIONS for Job Information Project Name: VICTORIA'S SECRET Contract No. : 600024401 City: CARLSBAD, CA 92008 Project Location: 2525 EL CAMINO REAL, SUITE #222 Date: 7/28/2017 Contractor Information Name of Contractor: SIMPLEX GRINNELL Address: 3568 RUFFIN ROAD SOUTH City: SAN DIEGO, CA 92123 Phone Number: 858-633-9125 E-mail: maenglishsimplexgrinneII.com Name of Designer: M. ENGLISH Authority Having Jurisdiction: City of Carlsbad Fire Prevention Bureau Design Remote Area Name 2 Remote Area Location Stock Room Occupancy Classification EH-2 Density (gpm/ft') 0.4 Area of Application (ft2) 850 Coverage per Sprinkler (ft2) 100 Number of Calculated Sprinklers 14 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 500 Total Water Required (incl. Hose Streams) (gpm) 1112.2 Required Pressure at Source (psi) 70.1 Type of System Wet Volume - Entire System (gal) 1033.1 gal Water Supply Information Date 4/5/2017 Location HYDRANT H60994 Source SRC Notes Misc Storage - EH2 (0.4/Entire Stock Room) File: C:\Users\maenglish\appdata\local\temp\FP Victorias Secret TSAC_11j899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 1 00 Job: VICTORIA'S SECRET Hydraulic Analysis for: 2 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lbs/ft2) Water Supply Parameters Supply 1: SRC Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 92 6050 42 Residual I I Available I Static Pressure I Flow I I Total Demand Required Pressure Node at Source (psi) Pressure I I (gpm) I I Pressure I I (gpm) I (psi) (psi) i (psi) SRC 92 42 6050 91.3 1112.2 70.1 Hoses Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) 500 Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 500 Sprinklers Ovehead Sprinkler Flow (gpm) 612.2 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 612.2 Other Required Margin of Safety (%) 10 BOR-1 - Pressure (psi) 66.5 BOR-1 -Flow (gpm) 612.2 Demand w/o System Pump(s) N/A File: C:\Users\maenglish\appdata\local\temp\FP Victonas Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 3 Job: VICTORIA'S SECRET Hydraulic Analysis for: 2 Flow, gpm File: C:\Users\maenglish\appdata\Iocal\temp\FP Victorias Secret TSAC_1 _1 _7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 4 Job VICTORIA'S SECRET Hydraulic Analysis for: 2 Graph Labels Label Description Values Flow (gpm) Pressure (psi) 51 Supply point #1 -Static 0 92 S2 Supply point #2 - Residual 6050 42 Dl Elevation Pressure 0 6.5 D2 System Demand 612.2 70.1 D3 System Demand + Add.Out.Hose 1112.2 70.1 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I I Pressure (psi) I Flow (gpm) I Pressure (psi) I @ Flow (gpm) I Supply 91 714.2 I 19.8 I 1112.2 Supply; Safety Pressure 82 672 10.8 1112.2 Open Heads Required ___________ Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/p5i1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) S201 Overhead 82 11.2 0.4 32.8 8.6 0.588 48.2 18.6 Sprinkler S202 Overhead 75 11.2 0.4 30 7.2 0.678 50.9 20.6 Sprinkler S203 Overhead 82 11.2 0.4 32.8 8.6 0.576 47.2 17.8 Sprinkler S204 Overhead 80 11.2 0.4 32 8.2 0.642 51.3 21 Sprinkler S205 Overhead 100 11.2 0.4 40 12.8 0.466 46.6 17.3 Sprinkler S206 Overhead 82 11.2 0.4 32.8 8.6 0.501 41.1 13.4 Sprinkler S207 Overhead 75 11.2 0.4 30 7.2 0.562 42.1 14.2 Sprinkler S208 Overhead 80 11.2 0.4 32 8.2 0.539 43.1 14.8 Sprinkler S209 Overhead 80 11.2 0.4 32 8.2 0.504 40.3 13 Sprinkler S210 Overhead 80 11.2 0.4 32 8.2 0.544 43.5 15.1 Sprinkler S211 Overhead 80 11.2 0.4 32 8.2 0.47 37.6 11.3 Sprinkler S212 Overhead 80 11.2 0.4 32 8.2 0.519 41.5 13.8 Sprinkler File: C:\Users\maenglish\appdata\local\temp\FP Victonas Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 S213 Overhead 75 11.2 0.4 30 7.2 0.514 38.6 11.9 Sprinkler S214 Overhead 100 11.2 0.4 40 12.8 0.4 40 12.8 Sprinkler File: C:\Users\maenglish\appdata\local\temp\FP Victortas Secret TSAC1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job : VICTORIA'S SECRET Hydraulic Calculations I Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/ps1½ fin ft2 psi psi It gpm gpm/ft2 psi gpm S214 Overhead Sprinkler 11.2 40 100 12.8 12.8 12 HEAD Open 0 0.4 -6.5 40 S205 Overhead Sprinkler 11.2 46.6 100 17.3 12.8 12 HEAD Open 6.6 0.466 -6.5 40 S211 Overhead Sprinkler 11.2 37.6 80 11.3 8.2 12 HEAD Open 5.6 0.47 -6.5 32 S206 Overhead Sprinkler 11.2 41.1 82 13.4 8.6 12 HEAD Open 8.3 0.501 -6.5 32.8 S209 Overhead Sprinkler 11.2 40.3 80 13 8.2 12 HEAD Open 8.3 0.504 -6.5 32 S213 Overhead Sprinkler 11.2 38.6 75 11.9 7.2 12 HEAD Open 8.6 0.514 -6.5 30 S212 Overhead Sprinkler 11.2 41.5 80 13.8 8.2 12 HEAD Open 9.5 0.519 -6.5 32 S208 Overhead Sprinkler 11.2 43.1 80 14.8 8.2 12 HEAD Open 11.1 0.539 -6.5 32 S210 Overhead Sprinkler 11.2 43.5 80 15.1 8.2 12 HEAD Open 11.5 0.544 -6.5 32 S207 Overhead Sprinkler 11.2 42.1 75 14.2 7.2 12 HEAD Open 12.1 0.562 -6.5 30 S203 Overhead Sprinkler 11.2 47.2 82 17.8 8.6 12 HEAD Open 14.4 0.576 -6.5 32.8 S201 Overhead Sprinkler 11.2 48.2 82 18.6 8.6 12 HEAD Open 15.4 0.588 -6.5 32.8 S204 Overhead Sprinkler 11.2 51.3 80 21 8.2 12 HEAD Open 19.3 0.642 -6.5 32 S202 Overhead Sprinkler 11.2 50.9 75 20.6 7.2 12 HEAD Open 20.9 0.678 -6.5 30 498 Node 17.9 14.5 NODE -7.6 497 Node 18 14.5 NODE -7.6 496 Node 18.3 14.5 NODE -7.6 495 Node 18.8 14.5 NODE -7.6 494 Node 20.2 14.5 NODE -7.6 481 Node 21.1 14.5 NODE -7.6 480 Node 21.2 14.5 NODE -7.6 479 Node 21.2 14.5 NODE -7.6 478 Node 21.7 14.5 NODE -7.6 477 Node 24.5 14.5 NODE -7.6 035 Node 27.5 14.5 NODE -7.6 File: C:\Users\maenglish\appdata\local\temp\FP Victonas Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 Job: VICTORIA'S SECRET Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psll/2 gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 034 Node 27.6 14.5 NODE -7.6 004 Node 27.9 14.5 NODE -7.6 033 Node 28 14.5 NODE -7.6 029 Node 28.1 14.5 NODE -7.6 032 Node 30.1 14.5 NODE -7.6 045 Node 35.5 14 NODE -7.4 052 Node 35.7 14 NODE -7.4 054 Node 38.2 14 NODE -7.4 239 Node 48.4 14 NODE -7.4 244 Node 59.6 -3 NODE 0 050 Node 60.6 2 NODE -2.2 031 Node 60.7 -3 NODE 0 047 Node 62.4 -3 NODE 0 048 Node 62.5 -3 NODE 0 049 Node 62.6 -3 NODE 0 039-0 Node 65.3 -11.67 NODE 3.8 039-I Node 65.9 -12.83 NODE 4.3 BOR-O Node 66.3 -13.56 NODE 4.6 BOR-I Node 66.5 -14 NODE 4.8 051-I Node 67.8 2 NODE -2.2 053 Node 70 -3 NODE 0 SRC Supply 70.1 -3 SUPPLY -612.2 . 0 File: C:\Users\maenglish\appdata\local\temp\FP Victonas Secret TSAC_1_1j899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 8 Job VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/ps11/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No S214 12 11.2 40 1 lx(us.Tee-Br)=5 6.32 120 12.8 498 14.5 40 1.049 lx(us.90)=2 7 0.4681 -1.1 13.32 6.2 498 14.5 0 2 3.65 120 17.9 497 14.5 40 2.067 0 0.0172 0 3.65 0.1 497 14.5 38.6 2 6.35 120 18 496 14.5 78.6 2.067 0 0.0601 0 6.35 0.4 496 14.5 41.5 2 3.65 120 18.3 495 14.5 120.1 2.067 0 0.1319 0 3.65 0.5 495 14.5 37.6 2 6.35 120 18.8 494 14.5 157.7 2.067 0 0.2183 0 6.35 1.4 494 14.5 43.5 2 lx(us.Tee-Br)=10 2.4 120 20.2 477 14.5 201.2 2.067 10 0.3429 0 12.4 4.3 477 14.5 166.7 2 lx(us.Tee-Br)=10 0.5 120 24.5 052 14 367.9 2.067 10 1.0483 0.2 10.5 11 052 14 244.3 4 lx(us.Tee-Br)=26.33 4.96 120 35.7 054 14 612.2 4.26 26.33 0.0795 0 31.29 2.5 054 14 0 4 2x(us.Tee-Br)=40 47.57 120 38.2 239 14 612.2 4.026 lx(us.90)=10 50 0.1047 0 97.57 10.2 239 14 0 5 lx(us.Tee-Br)=25 37.67 120 48.4 244 -3 612.2 5.047 4x(us.90)=48 73 0.0348 7.4 110.67 3.9 244 -3 0 6 lx(coupling)=1 76.94 120 59.6 031 -3 612.2 6.065 1 0.0142 0 77.94 1.1 031 -3 0 8 lx(coupling)=2.33 108.17 120 60.7 039-0 -11.67 612.2 8.329 7x(us.90)=146.87 149.2 0.003 3.8 257.36 0.8 039-0 -11.67 0 8 1.17 0 65.3 AV-1 Check 039-1 -12.83 612.2 0 0 0.1455 0.5 *** 1.17 0.2 039-I -12.83 0 8 lx(coupling)=2.33 0.73 120 65.9 BOR-O -13.56 612.2 8.329 2.33 0.003 0.3 3.06 0 BOR-O -13.56 0 8 0.44 0 66.3 BFV-N BaR-1 -14 612.2 0 0 0.0664 0.2 0.44 0.0 BOR-I -14 0 8 lx(coupling)=2.33 106.1 120 66.5 047 -3 612.2 8.329 4x(us.90)=83.92 127.05 0.003 -4.8 lx(us.Tee-Br)=40.8 233.15 0.7 File: C:\Users\maenglish\appdata\local\temp\FP Victonas Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright tI 2002-2012 Tyco Fire Protection Products Page 9 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi½) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 047 -3 0 8 lx(coupling)=3.52 6.83 140 62.4 048 -3 612.2 8.55 3.52 0.002 0 10.36 0.0 048 -3 0 8 lx(us.90)=25.42 51.67 150 62.5 049 -3 612.2 7.961 25.42 0.0025 0 77.081 0.2 049 -3 0 8 lx(us.90)=31.7 5 140 62.6 050 2 612.2 8.55 31.7 0.002 -2.2 36.7 0.1 050 2 0 8 6.42 0 60.6 Wilkins350AD 051-1 2 612.2 0 0 1.1372 0 A 6.42 7.3 *** 051-I 2 0 8 lx(elbow.22.5)=7.93 5 140 67.8 053 -3 612.2 8.55 7.93 0.002 2.2 12.93 0.0 053 -3 0 8 10 150 70 SRC -3 612.2 7.961 0 0.0025 0 10 0.0 SRC 70.1 Path No: 2 S211 12 11.2 37.6 1 lx(us.Tee-Br)=5 9.75 120 11.3 495 14.5 37.6 1.049 3x(us.90)=6 11 0.417 -1.1 20.75 8.7 495 18.8 Path No: 3 S205 12 11.2 46.6 1 lx(us.Tee-Br)=5 9.7 120 17.3 004 14.5 46.6 1.049 2x(us.90)=4 9 0.6222 -1.1 18.7 11.6 004 14.5 0 2 9.28 120 27.9 029 14.5 46.6 2.067 0 0.0229 0 9.28 0.2 029 14.5 51.3 2 lx(us.Tee-Br)=10 12.4 120 28.1 032 14.5 98 2.067 10 0.0904 0 22.4 2 032 14.5 146.3 2 lx(us.Tee-Br)=10 0.5 120 30.1 045 14 244.3 2.067 10 0.4912 0.2 10.5 5.2 045 14 0 4 12.67 120 35.5 052 14 244.3 4.26 0 0.0145 0 12.671 0.2 052 35.7 File: C:\Users\maenglish\appdata\local\temp\FP Victorias Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 10 Job VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/p51½) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 S213 12 11.2 38.6 1 lx(us.Tee-Br)=5 5.42 120 11.9 497 14.5 38.6 1.049 3x(us.90)=6 11 0.4377 -1.1 16.42 7.2 497 18 Path No: 5 S209 12 11.2 40.3 1 lx(us.Tee-Br)=5 9.75 120 13 478 14.5 40.3 1.049 3x(us.90)=6 11 0.4753 -1.1 20.75 9.9 478 14.5 126.3 2 lx(us.Tee-Br)=10 1.25 120 21.7 477 14.5 166.7 2.067 10 0.2419 0 11.25 2.7 477 24.5 Path No: 6 S206 12 11.2 41.1 1 lx(us.Tee-Br)=5 6.7 120 13.4 481 14.5 41.1 1.049 3x(us.90)=6 11 0.4913 -1.1 17.7 8.7 481 14.5 0 2 5.65 120 21.1 480 14.5 41.1 2.067 0 0.0181 0 5.65 0.1 480 14.5 42.1 2 0.5 120 21.2 479 14.5 83.2 2.067 0 0.0668 0 0.5 0.0 479 14.5 43.1 2 3.85 120 21.2 478 14.5 126.3 2.067 0 0.1448 0 3.85 0.6 478 21.7 Path No; 7 S212 12 11.2 41.5 1 lx(us.Tee-Br)=5 4.32 120 13.8 496 14.5 41.5 1.049 lx(us.90)=2 7 0.5019 -1.1 11.32 5.7 496 18.3 Path No: 8 S208 12 11.2 43.1 1 lx(us.Tee-Br)=5 4.82 120 14.8 479 14.5 43.1 1.049 2x(us.90)=4 9 0.5384 -1.1 13.82 7.4 479 21.2 Path No: 9 S210 12 11.2 43.5 1 lx(us.Tee-Br)=5 4.32 120 15.1 494 14.5 43.5 1.049 lx(us.90)=2 7 0.5475 -1.1 11.32 6.2 494 20.2 File: C:\Users\maenglish\appdata\local\temp\FP Victorias Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 11 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi½) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 10 S207 12 11.2 42.1 1 lx(us.Tee-Br)=5 8.68 120 14.2 480 14.5 42.1 1.049 lx(us.90)=2 7 0.5155 -1.1 15.68 8.1 480 21.2 Path No: 11 S203 12 11.2 47.2 1 lx(us.Tee-Br)=5 6.78 120 17.8 033 14.5 47.2 1.049 3x(us.90)=6 11 0.6362 -1.1 17.78 11.3 033 - 14.5 99.1 2 lx(us.Tee-Br)=10 1.25 120 28 032 14.5- 146.3 2.067 10 0.1901 0 11.251 1 2.1 032 30.1 Path No: 12 S201 12 11.2 48.2 1 lx(us.Tee-Br)=5 4.08 120 18.6 035 14.5 48.2 1.049 3x(us.90)=6 11 0.6624 -1.1 - 15.08 10 035 14.5 0 2 5.65 120 27.5 034 14.5 48.2 2.067 0 0.0244 0 5.65 0.1 034 14.5 50.9 2 4.35 120 27.6 033 14.5 99.1 2.067 0 0.0924 0 4.35 0.4 033 28 Path No: 13 S204 12 11.2 51.3 1 lx(us.Tee-Br)=5 4.02 1201 21 029 14.5 51.3 1.049 lx(us.90)=2 7 0.7431 -1.1 11.02 8.2 029 28.1 Path No: 14 S202 12 11.2 50.9 1 lx(us.Tee-Br)=5 4.02 120 20.6 034 I 14.5 50.9 1.049 lx(us.90)=2 7 0.7306 -1.1 11.02 8 034 27.6 File: C:\Users\maenglish\appdata\local\temp\FP Victorias Secret TSAC_1_1_7899sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 12 Job: VICTORIA'S SECRET Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 35.17 ft/s occurs in the following pipe(s): (052-477) "' Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: C:\Users\maenglish\appdata\local\temp\FP Victonas Secret TSAC11_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 13 Job: VICTORIA'S SECRET Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: SRC; Supply Name:SRC 105 100 95 90 85 80 75 70 65 60 55 50 ( 45 40 35 30 25 20 IS 0 o o 0 0 0 0 0 0 0 0 0 0 S S S S S Flow, gpm Pressure Loss Function Design Area: 2; BFP Ref.: 709 (WiIkins350ADA, Size = 8); Inlet Node: 051-I; Outlet Node: 050 9.56 8.56 psi 612.2 gpmj 7.56 CL 6,56 U) 5.56 U) C) a. 4,56 3.56 2.56 .56 0.56 0 en en en vi 0 ci o 0 vi 0 0 0 0 en en vi en 0 ci 0 0 0 0 t 00 0 vi Vi '0 0 '0 Flow, gpm File: C:\Users\maenglish\appdata\IocaI\temp\FP Victorias Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 14 2.085 0.585 4 Job: VICTORIA'S SECRET Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 707 (BFV-N, Size = 8); Inlet Node: BOR-I; Outlet Node: BOR-O Flow, gpm Pressure Loss Function Design Area: 2; Valve Ref.: 708 (AV-1 Check, Size = 8); Inlet Node: 039-I; Outlet Node: 039-0 Flow, gpm File: C:\Users\maenglish\appdata\Iocal\temp\FP Victonas Secret TSAC_1_1_7899.sv$ Date 9/27/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 15 pc20L+ -02-24 tq a Worldwide Fire Protection Contacts www.tyco-fire.com Products Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb 1Y3551 - 5 mm bulb APRIL 2016 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353-01-E) as Quick Response. 1Y3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). 1Y3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (1Y3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/ps1112 (80,6 LPM/bar"2) TFPI8I TFPI81 Page 2 of 4 Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ............Chrome Plated Steel Guide Pins..................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb...............................Glass Cap .....................Bronze or Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Protection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. CM Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NPT FRAME SUPPOR CUP WITI ROLL FORIJ THREADS GUIDE PINS (2) DEFLECTOR Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. LECTOR ROPPED POSITION) EALING SEMBLY CAP BULB PRESSION CREW SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO H U RETAINER SUPPORT J WITH THREAD CUP UNTIL 0 0 _- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING SOLDER 77! COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY -\ V MANUFACTURER DEFLECTOR COVER PLATE PRESET GAP IN DROPPED RETAINER 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE DIAMETER DIMENSION A 3/16 to 11/16 (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFP181 Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. Nif.)ifq As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust-Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. TFP18I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT BEVEL AS ('UP / CEILING -\ SEAL COVER \ SHOWN PLATE RETAINER ASSEMBLY SUPPORT DUST I AIR LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N* (specify): 155°F (68°C1 200°F (93°C1 TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Use Suffix "I" for ISO 7-1 connection; for example, 51-792-1-155-I Separately Ordered Cover Plate! Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 58-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1 -215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation Fire Protection Products tqccs Ffre Protection Worldwide Contacts www.tyco-fire.com I Products Series ELO-231B - 112 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description TYCO Series ELO-231 B 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprinklers of the frangible bulb type. They are standard response, spray sprinklers that produce a hemi- spherical water distribution pattern below the deflector. The 11.2 K-factor, ELO-231B Sprinklers were subjected to full-scale, high-piled storage fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231B Sprinklers, making their use highly advantageous in high density applications, such as the pro- tection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy components used in Series ELO-231B sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- sentative of all possible corrosive atmospheres. Consequently, it is rec- ommended that the end-user be con- sulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 concentration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An upright intermediate level version of the Series ELO-231 B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231B Upright Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series ELO-231B Sprinklers can be obtained by utilizing the Series ELO-231B Pendent Sprinkler with the WS-2 Shield. If there is a pos- sibility of the pendent intermediate level version being exposed to mechanical damage, a G-2 Guard can be added. MUM The 11.2 K-factor, Series ELO-231B Upright and Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Installation of Series ELO-231B Pendent Sprinklers in recessed escutcheons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. NOVEMBER 2016 Sprinkler Identification Numbers (SINs) TY5151 - Upright 11.21K, 3/4" NPT TY5251 - Pendent 11.2K, 3/4" NPT TY5851 - Upright 11.21K, 1/2" NPT TY5151 is a redesignation for Central SIN C5151. TY5251 is a redesignation for Central, Gem, and Star SINs C5251, G1871, and S2531, respectively. TY5851 is a redesignation for Central SIN C5851. TFP342 L 7/16' (11,1 mm) NOMINAL MAKE-IN UPRIGHT TY5851 VRENCH FLATS 1/2(12,7mm) NOMINAL MAKE-IN UPRIGHT TY5151 TFP342 Page 2 of 4 1/2' (12,7 mm) NOMINAL MAKE-IN FHREAD RELIEF IPT PENDENT TY5251 Components: 1 - Frame El 2 - Seal Assembly 3 - Cap 4 - Bulb 5 - Compression Screw 6 - Deflector* CROSS SECTION * Temperature rating is indicated on deflector. FIGURE 1 SERIES ELO-231B 11.2K UPRIGHT 3/4" NPT (TY5151), UPRIGHT 1/2" NPT (TY5851), AND PENDENT 3/4" NPT (TY5251) SPRINKLERS, STANDARD RESPONSE Technical Data Approvals UL and C-UL Listed FM Approved NYC Approved (Refer to Table A for complete approval information, including corrosion-resis- tant status. The approvals apply to the service conditions indicated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=11.2 gpm/psi" (161,4 Ipm/bar½) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame ............................Bronze Cap ..............................Bronze Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb (5 mm dia.) .....................Glass Compression Screw .................Bronze Deflector ..........................Bronze Design Criteria UL and C-UL Listing Requirements TYCO Series ELO-231B 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers are to be installed in accordance with NFPA 13 standard sprinkler position and area/ density flow calculation requirements for light, ordinary, or extra hazard occu- pancies, as well as high-piled storage occupancies (solid-piled, palletized, rack storage, bin box, and shelf storage including but not limited to Class l-lV and Group A plastics) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. FM Approval Requirements The 11.2 K-factor, Model ELO-231B (TY5151, 1Y5251 & TY5851) Sprinklers are to be installed in accordance with the applicable control mode density/ area guidelines provided by FM Global. (FM Approval guidelines may differ from UL and C-UL Listing criteria.) "FITTING SIDE TOWARDS SPRINKLER FITTING WRENCH RECESS / (END "A") FIGURE 2 W-TYPE 3 SPRINKLER WRENCH Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. TFP342 Page 3 of 4 SPRINKLER FINISH SPRINKLER TEMPERATURE BULB NATURAL CHROME I PLATED LEAD WAX WAX-OVER-LEAD TYPE RATING LIQUID BRASS COATED COATED COATED 155°F (68°C) Red UPRIGHT (TY5151&TY5851) 1, 2, 3, 4 200°F (93°C) Green 286°F (141°C) Blue 3 3* 155°F (68°C) Red PENDENT 1, 2, 3, 4 200°F (93°C) Green 286°F (141°C) Blue 3 Notes: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories. Inc. for use in Canada (C-UL) Approved by FM Global (FM Approvals) Approved by the City of New York (NYC) under MEA 291-04-E Listed/Approved for a maximum ceiling temperature of 150°F (66°C). TABLE A 11.2K SERIES ELO-231B UPRIGHT AND PENDENT SPRINKLERS, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS Installation TYCO Series ELO-231B 11.2K Stan- dard Response, Standard Coverage Upright and Pendent Sprinklers must be installed in accordance with this section. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 10 to 20 lbs.-ft. (13,4 to 26,8 Nm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to- maximum torque of 7 to 14 lbs-ft. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with con- sequent leakage or impairment of the sprinkler. Notes: Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approxi- mately 1/16 inch (1,6 mm) for the 155°F (68°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. Do not attempt to make up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series ELO-231B Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Note: Pendent sprinklers are to be installed in the pendent position; upright sprinklers are to be installed in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 3 Sprinkler Wrench (Ref. Figure 2), except that an 8 or 10 inch adjustable wrench is to be used for wax-coated sprinklers. With reference to Figure 1, the W-Type 3 Sprinkler Wrench or the adjustable wrench, as applicable, is to be applied to the wrench flats. When installing wax-coated sprinklers with the adjustable wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench-tightening the sprinkler, the jaws of the wrench are to be adjusted to just contact the sprin- kler wrench flats. After wrench-tight- ening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be inspected and the wax coating retouched (repaired) whenever the coating has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gently applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. Notes: Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau- tions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color-coded). Only the correct color-coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previ- ously described, touch the rod to the area requiring additional wax with the rod angled downward, and then touch the wax stick to the rod approximately 1/2 inch away from the area requiring retouching. The wax will melt and run down onto the sprinkler. TFP342 Page 4 of 4 P/N* 50-XXX-X-XXX SIN SPRINKLER TEMPERATURE FINISH RATING 501 11.2K UPRIGHT (1/2" NPT) TY5851 NATURAL 1 BRASS 155 155°F (68°C) 510 11.2K UPRIGHT (3/4" NPT) TY5151 6 WAX COATED 200 200°F(93°C) 512 11.2K PENDENT (3/4" NPT) TY52 7 LEAD COATED 286 286°F(141°C) 8 WAX-OVER-LEAD COATED r9 CHROME PLATED TABLE B SERIES EL0231 11.2K UPRIGHT AND PENDENT SPRINKLERS, STANDARD RESPONSE PART NUMBER SELECTION Care and Maintenance TYCO Series ELO-231B 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Sprinkler Assemblies with NPT Thread Connection Specify: Series ELO-231B 11.2K Stan- dard Response (specify Pendent or Upright) Sprinkler, SIN (specify), (specify temperature rating), with (specify) finish, P/N (specify from Table B) Sprinkler Wrench Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Wax Sticks (for retouching wrench-damaged wax coating) Specify: (specify Color) color-coded Wax Stick for retouching (specify tem- perature rating) temperature rated Series ELO-231B Sprinklers, P/N (specify): Red for 155°F .................56-065-1-155 Blue for 200°F and 286°F 56-065-1-286 Notes: Each wax stick is suitable for retouching up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 1500F). GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of the DuPont Corporation. Fire Protection Products tqccs Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 EVOTM The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2' NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/p5i1'2 (80,6 LPM/bar112) FEBRUARY 2014 1 : Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFP172 Page 20f4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector. can be provided on special request. 1/2' 7/16 (11,1 mm) NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON ESCUTCHEON PLATE 6 - Deflector DEFLECTOR * SEATING SURFACE I 7/16 I (11,1 mm) I NOMINAL 2 50,8 mm) \ MAKE-IN _____ 2' I _____ 1-3/8" (50,8 mm) I (34,9 mm) I I 1/2 NPT** DEFLECTOR * 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (7Y323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE / ENCH RECESS (USE ONLY - END A) FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. -. 2-7/8 DIA. (73,0 mm) - 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER (3,2 mm) FITTING 5/8' (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) ,,; MOUNTING 1/8" J ____ SURFACE ______ CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 3/4 (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON -. 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. -. FITTING (57,2 mm) 5/16±1/4 \ 1/2' (12,7 mm) (7,9±6,4 mm) FLUSH MOUNTING (3; mm) /8 J ___ I SURFACE \\H/ \ CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I SPRINKLER I TEMPERATURE I FINISH -i- RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2NPT) TY313 3 PURE WHITE (RAL9010)°° POLYESTER 371 5.6K PENDENT (1/2 NP TY323 4 SIGNAL WHITE (RAL9003) 175 175-F (79-q POLYESTER Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F (57°C) 155 155°F (68°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products AB Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. I FEATURES i' SPECFV'AT JON SUBMITTAL SHFET APPLICATION Designed for installation on potable water connections in fire sprinkler systems to protect against both backsiphonage and L backpressure of polluted water into the potable water supply. - Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. STANDARDS COMPLIANCE (Sizes 2 112"-10" Horiz. & Vert.) (12" Horizontal Only) Sizes: U 2 1/2" U 3" U 4" U 6" U 8" U 10" U 12" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI B16.1 Class 125 OPTIONS (suffixes can be combined) LI - with OS & Y gate valves (standard) U L - less shut-off valves (flanged body connections) U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U CFM - with cu ft/min meter U G - with groove end gate valves U FG - with flanged inlet gate connection and grooved outlet gate connection U P1 - with Post Indicator Gate Valve (3-10") ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model XI) U OS & Y Gate valve tamper switch (OSY-40) U Test Cock Lock (Model TCL24) ASSE® Listed 1048 (Sizes 2 1/2" thru 12") CSA® Certified 1364.5 (Sizes 2 1/2" thru 8") AWWA Compliant C510 (Sizes 2 1/2" thru 12") UL® Classified (Sizes 2 1/2" thru 12") C-UL® Classified (Sizes 2 1/2" thru 12") FM® Approved (Sizes 2 1/2" thru 10") NYC MEA 147-99-M Vol 4 (2-1/2" - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 10") MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDAApproved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM, NSF Listed Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYL, NSF Listed Springs Stainless Steel, 300 Series MODEL 350DAG SHOWN ABOVE DIMENSIONS & WEIGHTS (do not include pkg.) MODEL DIMENSION ___________ ___________ _(approximate) WEIGHT 350DA SIZE in. mm A in. mm B LESS GATE VALVES in. mm C in. mm D in. mm E OS&Y OPEN in. I mm E OS&Y CLOSED in. mm F in. mm WITHOUT GATES VALVES lbs. I kg WITH OS&Y GATE VALVES lbs. kg 21/2 65 31 787 157/8 403 33/4 95 9 229 163/8 416 137/8 352 31/2 89 68 30.9 178 80.8 3 80 1 32 813 157/8 403 M 95 9 229 187/8 479 155/8 397 31/2 89 68 309 198 90 4 WO 375/8 956 2 495 41/2 114 9 229 223/4 578 4 464 6 152 106 48 296 134.4 6 150 443/4 1137 231/2 597 51 O 102 267 301/8 765 233M 1 603 7 1 178 180 81.7 480 29 8 200 603/4 1543 373/4 959 10 254 12 305 373/4 959 291/4 743 82 216 374 170 850 3859 10 250 633/4 1619 373/4 959 10 254 12 305 453/4 1162 353/8 899 81/2 216 404 183 1 1222 554.8 12 300 661/4 1683 38 965 10 254 12 305 531/8 1349 405/8 1032 8718 226 463 210 1 16231 736.2 Page 1 of 2 WILKINS a Zurn Company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com 0'- 0 0.0 0 500 1000 1500 2000 2500 3000 3500 FLOW RATES (GPM) 4000 VERTICAL INSTALLATION FLOW CHARACTERISTICS MODEL 350DA 2 1/2",3" & 4" (STANDARD & METRIC) FLOW RATES (us) 0.0 12.6 25.2 37.9 15 (4) 0 1 LU 10 U) U)e:. U) W Ix 0. 200 400 600 FLOW RATES (GPM) MODEL 350DA 6" & 8" (STANDARD & METRIC) FLOW RATES (us) 31.5 63.1 94.6 126.2 0 500 1000 FLOW RATES (GPM)1500 MODEL 350DA 10" & 12" (STANDARD & METRIC) FLOW RATES (us) 0.0 31.5 63.1 94.6 126.2 157.7 189.3 TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless other- wise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 1 5288 50.5 103 co Co 0 69 -J of co 34 Q) LU 0 0 800 157.7 j 103 III 69 . —1 E0 -I :- 2500 283.9 103 69 —I (K CL —I E134 III i0 0 4500 OUTDOOR INSTALLATION - -- 2000 220.8 252.4 SPECIFICATIONS The Double Check Detector Backflow Prevention Assembly shall be ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NoryP' (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a WILKINS Model 350DA. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com Page 2 of 2