Loading...
HomeMy WebLinkAbout5830 EL CAMINO REAL; ; FPC2017-0093; Permit(City of PERMIT REPORT Carlsbad Print Date: 02/17/2022 Permit No: FPC2017-0093 Job Address: 5830 EL CAMINO REAL, CARLSBAD, CA 92008-8816 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090503100 Track #: Applied: 04/12/2017 Valuation: $599,048.80 Lot #: Issued: 05/10/2017 Occupancy Group: Project #: Finaled Close Out: 02/22/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: UPPER DECK -FIRE ALARM (NEW) FPContractor: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, # STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Submittal Package for: Upper Deck 5830 El Camino Real Carlsbad, CA 92008 River Fire and Security 8920 Activity Road, Suite J San Diego, CA 92126 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Remote Annunciator Power Supply Cellular Communicator Document Cabinet Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe FPC20I 7-0093 DPG 5830 EL CAMINO REAL 4/7/2017 0 Farenhyt Intelligent Fire Alarm Control Panel IFP-50 IFP-50 is an intelligent analog/addressable fire control panel (FACP). lFP-50 has a single line circuit (SLC) loop for connecting addressable detectors and modules and has two notification appliance circuits that can be programmed for notification outputs or auxiliary power. lFP-50 also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. IFP-50 supports a variety of other devices that can be added to the system such as RA-100 or RA-1000 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module, and SD or IDP devices. Features Built-in support for up to 50 SD devices or 50 IDP detectors and 50 IDP modules • Uses standard wire—no shielded or twisted pair required Built-in digital communicator for remote reporting of system activity and system programming Central station reporting by point or by zone Jumpstar auto-programming Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC • Distributed, intelligent power Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® Sensor sensitivity settings and day/night sensitivity setting and automatic drift compensation • Notification circuits can be configured as 1 Class A (Style Z), 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in annunciator with a backlit 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 24 VDC Two built-in Form C programmable relays rated at 2.5 amps at 24 VDC SLC device locator can be used to locate a single or multiple devices on a SLC loop System automatically performs detector sensitivity test 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Non volatile event history stores up to 1000 events 125 software zones and 125 output groups D SILENT KNIGHT by Honeywell Agency Listings US L MEA t~ S 429-92-E Vol. XVI IFP-50 2.5 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 7 amp hours). Programmable date setting for Daylight Saving Time Compatibility The lFP-50 SLC supports multiple device types of the same protocol: SD IDP You cannot mix SD and IDP devices on a FACP. However, any combination of addressable devices of the same protocol can be used on the IFP-50. Specifications Physical Dimensions: 12.75W x 15.2"H x 3.4"D (36.8 W x 62.9 H x 9.8 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red P/N 350328 Rev J © 2014 Honeywell International Inc. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Primary AC: 120 VRMS @50/60 Hz, 2.7A Total Accessory Load: 2.5A @ 27.4 VDC power-limited Standby Current: 200 mA Alarm Current: 365 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Notification Appliance Circuits Two circuits that can be programmed individually as: Notification Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Auxiliary Power Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Indicator Lights Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced Trouble (Yellow): Flashes when a trouble condition exists; solid when trouble silenced Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA13, NFPA15, NFPA16, NFPA7O, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listing; CSFM 170-0559: 144; MEA 429-92-E Vol XVI Approved Releasing Solenoid Manufacturer Part Number Rating Asco T8210A107 24 VDC, 2.5A Asco 8210G207 24 VDC, 2.5A Ordering Information IFP-50 Intelligent Fire Alarm Control Panel. SBUS Accessories RA-100 Remote Annunciator. Similar in operation and appearance to FACP annunciator. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. 5496 Intelligent Power Module. 6 amp power module that provides four additional power limited notification appliance circuits. 5824 Serial/Parallel Printer Interface Module. Provides one parallel and one RS-232 serial port for connecting a printer to IFP-50. 5880 LED I/O Module. Provides 40 LED outputs, eight normally open dry contacts inputs and one piezo output. 5865-3 & 5865-4 LED Fire Annunciators. Provides 30 programmable LED outputs and a piezo sounder. 5883 Relay Interface Board. Provides 10 general purpose Form C relays. Used with 5880. SD and IDP Devices See the specification sheets listed below for a complete listing of the SD and IDP devices. 350360 SD Devices data sheet 350361 Intelligent Device Protocol (IDP) Devices data sheet Miscellaneous Accessories 5650/5651 Silent Knight Software Suite. Provides programming, upload/download, and event reporting. Order 5650 for PC parallel port compatibility or 5651 for PC USB port compatibility 5670 Silent Knight Software Suite. Provides facility monitoring RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SP-TR Small panel trim ring. Use to flush mount the panel. 16.975" H x 14.630" W. I D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203)484-7118. For Technical support, please call 800-446-6444. www.farenhyt.com Assembled in the U.S.A. SILENT F arenhyt KNIGHT by Honeywell Remote Annunciator Agency Listings RA-1000 ! MEA 429-92-E Vol IX The RA-1000 is a remote annunciator used to operate and APPROVED program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of I the lFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on 4 a as alarms, supervisories, troubles, system silenced and AC power losses occur. U, I Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Installation Larger keypad buttons for system reset and silence The RA-1000 can be surface or flush RS-485 interface to panel mounted. Use the optional trim ring for surface Operation and appearance is identical to IFP-1000 built-in mounts. When flush mounting an electrical annunciator box is optional. If using an electrical box, use Install up to eight RA-1000s per FACP a 4S, single-gang, or double-gang box. Support for simultaneous use of multiple RA-1000s Compatibility On-board piezo sounder audibly indicates alarms, troubles, The RA-1000 is compatible with the following and supervisories FACPs: Five status LEDs for alarm, supervisory, trouble, silence and • IFP-1000ECS Emergency Communication AC power conditions System with Fire Alarm Control Panel Available in red or light gray • IFP-100ECS Emergency Communication Wiring lengths up to 6000 ft. from the FACP (depending on System and Fire Alarm Control Panel wire gauge and number of devices on SBUS) • IFP-1000 Intelligent Fire Panel • UL listed, complies with NFPA 72 • IFP-100 Intelligent Fire Panel CSFM approved • IFP-50 Intelligent Fire Panel MEA P/N 350071 Rev D Copyright © 2012 Honeywell International Inc. Flexput' is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight IFP-1 000 FACP RA-1000 RA-1000 RA-1000 1 n - a Quo a,a I'M Up to 8 RA-1000 per system 80-character backlit LCD display (4 lines with 20 characters each) Wiring lengths up to 6000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA72 UL Listed; CSFM 7170-0559:135; MEA 429-92-E Vol. IX; FM Approved Ordering Information RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1 000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring. For surface mounting. 5860TG Gray Trim Ring. For surface mounting. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0144 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURlTY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models *lFP50 and *5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: lFP-50, 5700 Control Units 7628 EOL Resistor 5860/5860R/RA-1000 Annunciator 5897 Power Supply 5496 *Notification Power Expander 5824 Serial/Parallel Interface 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SDSOO-LlM Line Isolation Module 5D505-61B Isolation Base RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0144 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Model 5495 Distributed Power Module In an emergency, you need maximum power. The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-446-6444. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices UL 864 & 1481 listed CSFM approved ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the Model 5495 Distributed Power Module 4.7k end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. D SILENT KNIGHT by Honeywell Model 5495 Distributed Power Module Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging Low AC power Auxiliary capacity: 33.0 AH Low battery condition power circuit: 1 Ambient temp.: 320 to 120° F Earth ground fault Notification 0° to 49° C Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on : Green condition on the host control signal circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 kQ EOL Output alternative to using the notification resistor required troubles (1-4): Yellow circuit trouble. on each Class B Approvals: Electrical Specification circuit 864 & 1481 UL: No. of inputs 2 NFPA: 72 AC input: 120 VAC at 2 amps Input CSFM Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A Model 5495 Blo10.1 ck Diagram Signal Circuit Output I Signal I I I Signal I I Input I Distributed Signal 2 Signal Circuit Output I Signal 2 Power I I - Input i Module 5495 I Signal 3 Signal 4 Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian circle Suite 100, Maple Grove, Mn 55369-4927. copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Reced 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 090 From Tyco Security Products 3G technology from DSC! Features That Make a Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IP receiver Automatically switches to 2G (EDGE/GFRS) if 3G service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via automated telephone activation system ('JRU), web-user or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/1I/111/lV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed The 3G401 OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-IP/11/111/IV/5). The 3G401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The 3G401 OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 and 2013 Editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G401 OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the FSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. In instances where the control panel does not support Contact ID or SIA (300 baud), the 3G401 OCF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard® System I-IP/11/1II/IV/5). DBC From Tyco Security Products Activating & Initializing the Unit Activating and initializing the 3G401 OCF can be done using the automated telephone activation system (VRU), mobile interface or web-user interface provided by 024 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The 3G401 OCF is UL listed under File S4019, Listing guide UO)O(, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the 3G401 OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G401 OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G401 OCF-USA ..........Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the 3G401 OCF requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013) rate plans to support the supervision requirements. Specifications Dimensions ................. 11-1/2" x 10" x3' (290 mm x 254 mm x 75 mm) Input Voltage................ 120 VAC Current Draw .............. 200 mA (standby) 400 mA (transmitting) Operating Environment 320 to 120° F (00 to 49° C) Weight......................... 12.8 lbs (5.8 kg) Optional Acessories Model Description GS-1 5ANT 15 ft extension antenna (internal use) GS-25ANT 25 ft extension antenna (internal/external use) GS-50ANT 50 ft extension antenna (internal/external use) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0161 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model 3G4010CF RF Communicator (GSM-GPRSI3G) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120V, 50/60 Hz, 0.3A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 06-03-15 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information fig In qatzo, IS0 9001 REGISTERED NFPA ., COMPANY MEMBER Made In U.S.A. V J4 Space Age Electronics, Inc. 2009 ED0549 L110559 Rev.D 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB Connector Key Ring Hooks Business Card Holder -, Prope,tyInto,n,tion MIni,esn, Required Documentation(SIG-FUN) Certifications end Approvals 161 System Instatlation Contractor . t.sl.d,,,!dcta.IINtm.5,,th(sSra,. 165 Athcr,ty Having Jurisdiction Equipment Information 'ae.,....ra. ..#. r8Cflk..Ue..d seam, 5*01554 500486.1725 00.50 .....50, LTIOSO4 002 1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) No Excuses, Just Solutions! This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 4854740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCXID 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFXIA and IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal lDP-Photo, IDP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACP5). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the lDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System SensoO PN RA100Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed D SILENT KNIGHT by Honeywell 11 A MEA - UL 225-02-E Vol. V 11313-Photo (Base not Included) Installation The lDP-Photo and IDP-Photo-T plug into a compatible IDP-series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors Compatibility The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following IDP-series detector bases: B21OLP 6" Mounting Base B501 4" Mounting Base B224B1 6" Isolator Base B224RB 6" Relay Base B200SR 6" Sounder Base The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following FACPs: • IFP-2000 I RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel lFP-1000 / ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel lFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350280 Rev G Copyright © 2015 Honeywell International Inc. Wiring IDP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical Height: 2.0" (5.0 cm) IDP-Photo Photoelectric Smoke Detector Diameter: 4.1" (10.4 cm) installed in B501 base IDP-Photo-T Photoelectric Smoke Detector with Thermal (135°F) Electrical IDP-PhotoR Photoelectric smoke detector, remote Operating Voltage: 15-32 VDC test capable, for use with DNR (W) duct SLC Standby and Alarm Current: 300 pA smoke detector Accessories Environmental Operating Temperature RA100Z Remote LED Annunciator. IDP-Photo: 320 - 120°F (0°C - 49°C) XR213 Detector Removal Tool. A removal and IDP-Photo-T: 321 - 100°F (0°C - 38°C) replacement tool for IDP plug-in detectors. Includes the 155-127-000. Humidity: 10% - 93% non-condensing M02-04-01 Detector Test Magnet. Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F M02-09-00 Test Magnet with Telescoping Handle. (57°C) XP-4 Extension Pole for XR2B. Extends from Velocity: 0 - 4000 fpm (0 - 20 mlsec) (suitable for 5-15 ft. installation in ducts) 155-127-000 Detector Removal Head. IDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) BCK-200B Black Detector Kit. For IDP-series nominal detectors. * Unless otherwise noted, specifications apply to lOP-Photo and IDP-Photo-T. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications KNIGHT are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT 5ECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-PHOTO, lDPPHOTOR*, lDP-PHOTO-T, lDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, 5K-PHOTO-I and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models lDP-PHOTO and lDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt Addressable Single Action and Dual Action Pull Stations lDP-Pull-SA & IDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[131) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. D SILENT KNIGHT by Honeywell Agency Listings MEA !! 67-02-E Vol. IX For IDP Pull DA IDP-Pull-SA IDP-Pull-DA Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with the following FACPs: IFP-2000/RPS-2000 Intelligent Fire Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350286 Rev E © 2010 Honeywell International Inc Class B Class A 1 Compatible FACP ccsj Class A Wiring: '=' 6 " 0 1 L cD 3 o Class B Wiring: Wiring IDP-Pull-SA & IDP-Pull-DA Pull Stations Specifications* Environmental Physical Operating Temperature 321 - 120°F (0°C - 49°C) Height: 5.5(14 cm) Humidity: 10% - 93% non-condensing Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Ordering Information IDP-Pull-SA Single Action Pull Station Housing Material: LEXAN polycarbonate resin IDP-Pull-DA Dual Action Pull Station Bi-Colored LED: Blinking Green: Normal Accessories Steady Red: Alarm BG-TR Optional trim ring. Switch: Single pole, single throw (SPST) normally open (N/O) SB-I/O Surface backbox, indoor/outdoor. switch which closes upon activation of the pull station * Unless otherwise noted, specifications apply to lDP-Pull-SA and Electrical IDP-Pull-DA. Operating Voltage: 15-32 VDC Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0157 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURlTY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model IDP-PULL-SA manual pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt IDP-Minimon The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications UL Listed Installation The IDP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. D SILENT KNIGHT 10 by Honeywell Agency Listings MEA 457.99.E Vol. V I, IDP-Minimon Compatibility The IDP-Minimon is compatible with the following FACPs: IFP-2000 I RPS-2000 Intelligent Fire Panel IFP-1000 I ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350279 Rev F Copyright © 20131-loneyweH International Inc Other Devices Wiring the 11312-Minimon Specifications Physical Height: 1.3" (3.3 cm) Width: 2.8" (7 cm) Depth: 0.5" (1.3 cm) Shipping Weight: 1.2 oz (37 g) Electrical Operating Voltage: 15 - 32 VDC Standby Current: 375 pA; 600 pA max (communicating, IDC shorted) End-of-Line Resistance: 47K 2 Initiating Device Circuit Wiring Resistance: 1,5002 max SLC Loop Resistance: 402 max. Wire Length: 6" mm. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information lDP-Minimon Miniature Monitoring Module D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION CIE OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT 5ECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, 5K-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, lDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, SK-Control, 5K-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SKRELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0026:0219 *Rev. 10-25-11 mt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNAUNG LISTED S5512 FM approved except 7125-1653:0504 04011 for ALERT models 1155-1653:0503 3057383 The System Sensor L.Series otters the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SyncsCircuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncsCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MD[3 listed to U[ 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit, The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6,9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDSS6SOO UL Current Draw Data U1U Max. Strobe 1l Draw !IW1:li"Fi 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts DC Input 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd llscd lsOcd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.lKTemporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.11K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86800 L-Series Dimensions 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes SCRL Strobe, Red PC2RL 2-Wire, Horn Strobe, Red SCWL Strobe, White PC2WL 2-Wire, Horn Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White "STEM 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Sensor. Product op c c It u subject to change -thou: notice. hint syste"ce"so'com .°$ SEIISO!? Phone' 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest cersion of this data sheet. AVDS8 6801 • 03/17 SYSTEM $ SENSOR® Field-Selectable Emergency Communications Devices System Sensor L-Series emergency communications devices and accessories combine application versatility with all the time- and money-saving benefits of the L-Series line. Emergency Communications Features: Plain or ALERT-printed white housings Clear or Amber lens strobes and speaker strobes Color lens attachments for use with clear lens wall or ceiling strobes Meets DoD specification requirements L-Series Features: Plug-in design for simplified installation and troubleshooting Mounting plate shorting spring easily tests wiring continuity Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings of: —Wall: 15, 30, 75, 95, 110, 135, 185 - Ceiling: 15, 30, 75, 95, 115, 150, 177 Rated from 32°F to 120°F (indoor devices) Optional tamper-resistant Torx head screw Compatible with System Sensor synchronization protocol Agency Listings SIGNALING & A1111.11EII 91 LISTED Horn sLobes: FM approved except for Strobes: 7125-1653:0504 05512, S4011 ALERT models and colored lenses. Horns/Horn Strobes: 7135-1653:0505 Speaker Strobes: Horn Strobes: 3057363, 3057072 Speaker Aliases: 7320-1653:0505 S4048 Speaker Strobes: 3057493 System Sensor L-Series, the broadest and most versatile line of notification devices available, includes a wide range of devices to meet emergency communications application requirements. ALERT-printed on white housings amber lens strobes and speaker strobes provide visual signaling for emergency communications in compliance with ANSI! UL 1638— Standard for General Signaling Visible Appliances. Other Plain or ALERT-printed models provide clear lenses for use with color lens strobe attachments (amber, blue, green, and red) that easily attach to strobe and speaker strobe devices without a candela derating. In addition, L-Series emergency communications devices include plain (non-printed) strobes, horn strobes, and speaker strobes. These devices, along with ALERT-printed devices and L-Series accessories, can meet a wide range of requirements for indoor applications, including emergency communications, general signaling, severe weather, and emergency response. All L-Series emergency communications and general signaling devices are compatible with the entire L-Series line and include all the same time- and money-saving innovations. For example, plug in design simplifies installation and reduces costly ground faults, universal mounting plates with onboard shorting springs test wiring continuity to speed installation and protect devices from damage, and field-selectable settings provide versatility and enable installers to quickly set each device to meet application requirements. L-Series Specifications General System Sensor L-Series strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact devices shall mount to a single-gang 2 x 4 x 17/8-inch back box. L-Series speaker strobes shall mount to a 4 x 4 x 21/a-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes, horn strobes, and speaker strobes shall have field-selectable candela settings, including 15, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The clear strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. Colored lens strobes shall be listed to ANSI/UL 1638 and shall be approved for Private Mode Emergency. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing all Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. The horn and horn strobe models shall operate on a coded or non-coded power supply. Speaker Strobe Combination The speaker strobe shall be a System Sensor L-Series Model listed to UL 1480 and UL 1971 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronzation modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Color Lens Strobe Attachment The System Sensor L-Series color lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with (plain non-fire-printed) System Sensor strobe devices. They shall mount to any wall or ceiling strobe and be rated from minus 35 degrees to 151 degrees Fahrenheit. The effective light loss for wall units shall be as follows Amber = 0%, Blue = -40%, Green = -65%, Red = -85% Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions Wall-Mount Strobe and Horn Strobe (including lens) 5.6"L x 4.7" W x 1.91"D (143 mm Lx 119 mm W x 49 mm D) SPS Speaker Strobe (including lens) 6.5" Lx 5.0" W x 2.3" D (165 mm L x 127 mm W x 58 mm D) Dimensions Ceiling-Mount Strobe (including lens) Electrical/Operating Specifications 68" diameter x 2,80 Nominal Voltage (strobes and horn strobes) Regulated 12 VDC or regulated 24 DC/FINR Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Operating Voltage Range B to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Operating Voltage Range with MDL3 8.5 to 17.5 (12V nominal) or 16.5 to 33V (24V nominal) Strobe Flash Rate 1 flash per second Speaker Frequency Range 400 to 4,000 Hz Speaker Power 1/4,1/2, 1, 2 watts bpeaker UL Reverberant (dBA @ loft.) 2W 1 W 1/W 1/4W Wall-Mount SPS Series 88 85 82 79 Ceiling-Mount SPC Series 88 85 82 79 AvD587lo2 UL Current Draw Data UL Max Strobe Current Draw (rnA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 110 N/A 148 179 115 N/A 158 191 135 N/A 172 209 150 N/A 189 228 177 N/A 226 264 185 N/A 222 257 Wall Candela Settings: 15, 30, 75, 95, 110, 135, 185 Ceiling Candela Settings: 15, 30, 75, 95, 115, 150, 177 UL Max. Current Draw (rnA RMA), 2-Wire Horn Strobe BVDC 16VDC DC Input 15 30 15 30 75 95 110 115 135 150 175 185 Temporal High 98 158 54 74 121 142 162 187 196 217 254 245 Temporal Low 93 154 44 65 111 133 157 185 184 211 249 235 Non-Temporal High 106 166 73 94 139 160 182 187 211 230 273 262 Non-Temportal Low 93 156 51 71 119 139 162 170 190 216 258 239 3.lKTemporal High 93 156 53 73 119 140 164 184 190 229 257 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 185 212 252 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 202 208 229 271 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 187 192 217 259 242 FWR Input 16VFWR 15 30 75 95 110 115 135 150 175 185 Temporal High 83 107 156 177 198 223 234 254 286 287 Temporal Low 68 91 145 165 185 199 223 229 262 271 Non-Temporal High 108 135 181 207 230 223 264 254 286 315 Non-Temportal Low 79 104 157 175 197 199 235 229 262 281 3.lKTemporal High 81 105 155 177 196 225 234 255 289 284 3.1K Temporal Low 68 90 145 166 186 196 222 229 260 276 3.1K Non-Temporal High 101 131 176 204 230 225 264 255 289 326 3.1K Non-Temporal Low 77 102 156 177 199 196 234 229 260 291 Wall Candela Settings: 15, 30, 75, 95, 110, 135, 185 Ceiling Candela Settings: 15, 30, 75, 95, 115, 150, 177 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. AvOS87lo2 L-Series Ordering Information Alert Devices SWL-CLR-ALERT Strobe, White, Wall, Clear Lens, Alert SWL-ALERT Strobe, White, Wall, Amber Lens, Alert SCWL-CLR-ALERT Strobe, White, Ceiling, Clear Lens, Alert SPSWL-ALERT Speaker Strobe, White, Wall, Amber Lens, Alert SPSWL-CLR-ALERT Speaker Strobe, White, Wall, Clear Lens, Alert SPSCWL-CLR-ALERT Speaker Strobe, White, Ceiling, Clear Lens, Alert Plain Wall Strobes SRL-P Strobe, Red, Wall, Plain SWL-P Strobe, White, Wall, Plain Plain Wall Horn Strobes P2RL-P Horn Strobe, Red, Wall, Plain P2WL-P Horn Strobe, White, Wall, Plain Plain Wall Speaker Strobes SPSRL-P Speaker Strobe, Red, Wall, Plain SPSWL-P Speaker Strobe, White, Wall, Plain Plain Ceiling Speaker Strobes SPSCWL-P Speaker Strobe, White, Ceiling, Plain Notes: All -P models have a plain housing (no "FIRE" marking on cover) Colored Lenses LENS-A2 Wall-Mount Lens Attachment, Amber LENS-B2 Wall-Mount Lens Attachment, Blue LENS-G2 Wall-Mount Lens Attachment, Green LENS-R2 Wall-Mount Lens Attachment, Red LENS-AC2 Ceiling-Mount Lens Attachment, Amber LENS-BC2 Ceiling-Mount Lens Attachment, Blue LENS-GC2 Ceiling-Mount Lens Attachment, Green LENS-RC2 Ceiling-Mount Lens Attachment, Red Bezel Kits* BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn/Strobe Ceiling Red Bezel Kit BZWC Horn/Strobe Ceiling White Bezel Kit BZSPR Speaker Wall Red Bezel Kit BZSPW Speaker Wall White Bezel Kit BZSPRC Speaker Ceiling Red Bezel Kit BZSPWC Speaker Ceiling White Bezel Kit *Each bezel pack ships in a package of 5. For bezel option add -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain) -SP (FUEGO), -PG (FOGO) for desired printing. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2O17 System Sensor. EAI.cOR Phone. 800-SENSOR2 • Fax: 630-377-6495 Product sped'catio'sucjectto change aithout notice. 'dsitsyste-"so'so'com to, current product information, including the latest version at this data sheet. www.systemsensor.com AvDS87102 • 03/17