HomeMy WebLinkAbout6161 EL CAMINO REAL; ; FPC2018-0186; PermitPERMIT REPORT (âity of Carlsbad Print Date: 03/02/2022 Job Address: 6161 EL CAMINO REAL, CARLSBAD, CA 92009-1602 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2131002400 Track #: Valuation: $80,369.28 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: VIASAT BUILDING 2 -SPRINKLER TI (8 HEADS) CONVERT FITNESS AREA TO OFFICES Permit No: FPC2018-0186 Status: Closed - Finaled Applied: 06/20/2018 Issued: 07/10/2018 Finaled Close Out: 02/22/2021 Inspector: Final Inspection: Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 - FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov I TIAN FPc-2o- (47 FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 171117 ViaSat B2 6161 El Camino Real Carlsbad, CA 92009 EXISTING FEATURES Sizes: U 21/2" U 3" U 8" U 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U G - with groove end OS&Y gate valves U L - less shut-off valves U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U - with cu ft/min meter APPLICATION Designed for installation on potable water fire protection lines to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. ASSE® Listed 1048 (Horizontal and Vertical Flow-Up) AMA Compliant C510 (Horizontal & Vertical Flow-Up) UL® Classified (Horizontal) C-UL® Classified (Horizontal) CSA® Certified (Horizontal and Vertical Flow-Up) FM® Approved (Horizontal and Vertical Flow-Up) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow-Up, except 10" vertical) MATERIALS Main valve body Cast Iron ASTM A126 Class B Access covers Cast Iron ASTM A126 Class B Coatings FDAApproved Epoxy finish Internals Stainless Steel, 300 Series Cast Bronze ASTM B 584 Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers DelrinTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U Gate valve tamper switch (OSY-40) B A DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL B E E WITHOUT WITH OS&Y SIZE A WITHOUT C D OS&Y GATE OS&Y F GATE GATE GATE VALVES GATE VALVES VALVES VALVES OPEN VALVES in. I mm I in. I mm in. mm in. I mm in. I mm in. I mm in. mm in. I mm lbs. I kg 2 1/21 65 371/81 943 22 559 4 102 10 254 163/8 416 137/8 352 4 1102 101 I 95.8 3 I 80 1381/8 I 968 22 559 4 1102 10 I 254 18 7/81 479 155/8 397 4 1102 101 I 104.9 14101640.112228011.5 8 200 711/81 1807 48 1219 71/21191 16 I 406 373/41 959 291/4 743 71/21191 847 I 600.6 10 1 2501841 /81 2137 58 1473 9 1229 18 I 457 453/41 1162 353/8 899 9 229 104 FLOW CHARACTERISTICS MODEL 950DA 2 1/2" & 3" (STANDARD & METRIC) FLOW RATES (Ifs) 12.6 25.2 37.9 50.5 ME I ,.zIII 1110 XIII FLOW RATES (GPM) MODEL 950DA 8" & 10" (STANDARD & METRIC) FLOW RATES (Ifs) 63.1 126.2 189.3 - 8" (200MM - 252.4 104 69 35 a: Cl) CI) LU 4000 LU 0'- cc 0 0 1000 2000 3000 FLOW RATES (GPM) *Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12(305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 780 1169 1559 2339 10" 1 1229 1843 2458 3687 PROTECTIVE ENCLOSURE I- 12 MIN. 30 MAX. SUPPORT DIRECTION OF FLOW MAIN INLET cD OUTDOOR INSTALLATION VERTICAL INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048, and supplied with full port OS&Y gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM Al 26 Class B), the seat ring and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a WILKINS Model 950DA. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com AitaUi icr 40.34 FireLock® V34, K14.0 Models V3421, V3425 Standard Response Extended Coverage/Ordinary Hazard (ECOH) Pendent, Recessed Pendent and Upright V3421 V3421 V3425 Pendent Recessed Pendent Upright Approvals/Listings: IJ LISTED See Victaulic Publication 10.01 for more details. Product Description: Model V34 ECOH sprinklers are designed to protect ordinary hazard occupancies with a maximum coverage area of 400 square feet with unobstructed or non-combustible obstructed ceiling construction as permitted by NFPA 13. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 5) and finishes to meet many design requirements. Coverage Extended spray coverage is up to 400 square feet (37.2 sq. m) per NFPA 13. Technical Specifications: Models: V3421 and V3425 Style: ECOH - Pendent, Recessed Pendent (V3421) and Upright (V3425) Nominal Orifice Size: 3/4'/20 mm K Factor: 14.0 Imp./20.2 SI.1 Nominal Thread Size: 3/4' N P1/20 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7.8 psi/53.8kPa Temperature Rating: See chart Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I V34, K14.0 I Publication 40.34 40.34 3326 Rev F updated 10/2014 © 2014 Victaulic company. All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock® I V34, K14.0 I Publication 40.34 Accessories: Installation Wrench El Open End: V34 El Recessed: V34 Sprinkler Finishes: Plain Brass Chrome Plated El Proprietary Nickel Teflon coating3 LI White Painted LI Custom Painted3 LI VC-2504 For escutcheons, boxes and other accessories refer to separate sheet. NOTE: Weather resistant recessed escutcheons available on request. I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. 2 Teflon is registered trademakr of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. Material Specifications: Pendent Deflector: UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: 3.0 mm Load Screw: UNS C65100 Pip Cap: CW602N brass alloy Spring: Beryllium nickel Seal: Teflon tape Frame: Die cast brass 65-30 Lodgement Spring: UNS S30200 LO Exaggerated for clarity Exaggerated for clarity 40.34 3326 Rev F Updated 10/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 \4taulicr victaulic.com I Sprinklers I FireLock® I V34, K14.0 I Publication 40.34 Approvals/Listings: Model APPROVALS/LISTINGS V3421 V3421 V3425 Orifice Size (inches) 3% ~ 34 Orifice Size (mm) 20 20 20 Nominal K Factor Imperial 14.0 14.0 14.0 Nominal K Factor 5j6 20.2 20.2 20.2 Response Standard Standard Standard Deflector Type Pendent Recessed Pendent up to 34 Upright Adjustment Room Size Feet/meters Approved Temperature Ratings F°IC° 14 X 14 4.3 X 4.3 cULus A A A 16 X 16 4.9 X 4.9 cULus A A A 18 X 18 5.5 X 5.5 cULus A A A 20 X 20 6.1 X 6.1 cULus A A A Listings and approval as of printing. Not all temperature rating combinations are Approved or Listed, check Victaulic for specific combinations. 6 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. Approved Temperature Ratings: Temperature Rating A— 155 F/68 C, 175 F/79 C 200 F/93 C,286 F1141°C 40.34 3326 Rev F Updated 10/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 3 j4tauiic° victaulic.com I Sprinklers I FireLock® I V34, K14.0 I Publication 40.34 Dimensions: 65 mm 2,S/'/ 41mm Pendent Product Dimensions - V3421 r 2//6O mm Max. Hole 2/51 mm Mm. Hole ;' 5t Typical CedingTile Finished Surface 36 mm MAXIMUM RECESS - 75 mm MAXIMUM EXTENSION ½' Adjustment Recessed - V3421 (drawing not to scale) 64 2r/8 /ôO mm Max. Hole 2/51 mm 24mm 16 mm Mm Hole j Typical Ceiling Tile 115/16"/ Finished tsurface 30 mm 49 rnm MAXIMUM RECESS 75 mm MAXIMUM EXTENSION 3/4 Adjustment Recessed - V3421 (drawing not to scale) Upright Product Dimensions - V3425 Coverage Area/Density: Sprinkler Performance Flow And Pressure (Minimum) V3421,V3425 OrdinaryHazardGroupI OrdinaryHazardGroup2 Coverage 0.15 gpm/sq. ft. 0.20 gpm/sq. ft. Area 6.1 mm/min 8.1 mm/mm Ft. x Ft. Flow Rate EndSprinkler Flow Rate EndSprinkler m x m GPM/LPM Pressure GPM/LPM Pressure 14 X 14 39.0 7.8 51.0 13.3 4.3X4.3 147.6 53.8 193.0 91.7 16X16 39.0 7.8 51.0 13.3 4.9X4.9 147.6 53.8 193.0 91.7 18 X 18 49.0 12.3 65.0 21.6 5.5X5.5 185.5 84.8 246.0 148.9 20 X 20 60.0 18.4 80.0 32.7 6.1 X 6.1 227.1 126.9 302.8 225.5 40.34 3326 Rev F Updated 10/2014 © 2014 Victaulic company. All rights reserved. viCtaulic.com 4 --11. AitauIicr ME Mani MMONEEM auuuaauuuuuau iumuuumusmuii uuivaaii uusuiiuiuiiuu uu mom INOME MMENNONE 10' 3,0 m 8' 2,4m 6' 1,8 m 4, 1,2 m 2' 0,6 m o 39.0 GPM 147,6 1PM 49.0 GPM 185,5 1PM 51.O GPM 193,0 1PM 60.0 GPM - - - 227,1 1PM 65,0 GPM 246,0 1PM 80.0 GPM 302,8 1PM victaulic.com I Sprinklers I FireLock® I V34, K14.0 I Publication 40.34 Distribution Patterns: Model V3421 K14.0 ECOH Pendent and Recessed Pendent Distribution Patterns - Trajectory ivaui uuu ME iiiaiaiuuuuua iiIa*iiIU•••UU!1! uuu 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 0.6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m 4,9 m 5,5 m 6,1 m Model V3425 K14.0 ECOH Upright Distribution Patterns - Trajectory 10' 3,0m 8' 2,4m 6' L8rn 4' L2m 2' 0,6 m 0 39.0 GPM 147,6 1PM 49.0 GPM 185,5 1PM 51.OGPM - - - - 193,0 1PM 60.0 GPM - - - 227,1 1PM 65.0 GPM 246,0 1PM 80.0 GPM 302,8 1PM 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 0,6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 43 m 49m 5,5 m 6,1 m Miniumum Installation Spacing Response Feet/meters V3421 - Standard 12.0 3.7 V3435 - Standard 8.0 2.4 NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.34 3326 Rev F Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 JtauIic victaulic.com I Sprinklers I FireLock® I V34, K14.0 I Publication 40.34 Ratings: All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in adjacent table. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Fl C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary C 155 F/68 C 100 Ff38 C Red Intermediate E 175 Ff79 C 150 Ff65 C Yellow Intermediate F 200 Ff93 C 150 F/65 C Green Intermediate J 286 Ff141 C 225 F/107 C Blue Available Wrenches: V34 Open End V34 Recessed Pendent Yes Yes Recessed Pendent - Yes Recessed Pendent Yes - WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: ME 001-610-559-3300. Installation Note Reference should always be made to the 1-40Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.34 3326 Rev F Updated 10/2014 lOt 2014 Victaulic Company. All rights reserved. victaulic.com 6 \J'ctauIic FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response - V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I411I19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. \4taUIic 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.1 Nominal Thread Size: ½' NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Speô Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: fl Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: El Open End: V27 Recessed: V27-2 Sprinkler Finishes: LII Plain Brass LII Chrome plated White painted3 LII Black painted3 Custom painted3 El Proprietary Nickel Teflon2 coating3 LII VC-2504 155, 200, 286 SR Only: LII Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 'jt41tauiic victaulic.com I Sprinklers I FireLocke I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 175°F/79°C 175F/79°C 175°F/79°C 175F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 135F/57°C 135°F/57°C 135°F/57C 135°F/57°C 155°F/68C 155°F/68C 135°F/57°C 155F/68C 155°F/68°C 135F/57C FM 175°F/79C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 20OF/93°C 360F/182C 360F/182C 286°F/141°C 286°F/141°C 135F/57C 135F/57C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135F/57C 175°F/79C 175°F/79C 155F/68C 155°F/68C 155F/68C 155°F/68°C NYC/MEA 62-99-E 200F/93C 2OOF/93°C 175°F/79°C 175°F/79°C 175F/79°C 175°F/79°C 286°F/141°C 286°F/141°C 200F/93C 200F/93°C 200F/93C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141 C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135F/57°C 155°F/68C 155°F/68C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 2O0F/93°C 200°F/93°C 200F/93°C 175F/79C 286°F/141°C 286°F/141°C 28&F/141°C 286'F/141 'C 286'F/141 'C 200°F/93C 360°F/182°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79C None None 155°F/68°C None None 200F/93°C 175°F/79C 28&F/141°C 200°F/93°C 360'F/1 82'C 135F/57°C 135°F/57'C 135°F/57°C 135°F/57C 155°F/68°C 155°F/68°C 135°F/57°C 155F/68°C 155F/68C 135F/57°C VNIIPO 175°F/79°C 175F/79°C 155°F/68C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93C 200F/93C 175°F/79°C 286'F/141 *C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200F/93°C 360°F/182°C 360F/182C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135F/57°C 155F/68C 155°F/68C VdS 175°F/79°C None None 175F/79C None None 200F/93C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 135F/5TC 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200F/93C 286°F/141°C 286°F/141°C 360°F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 O 2014 Victaulic Company. All rights reserved. victaulic.com 3 '\jtauIic 1 Sfe/ 37 mm 2 60 1W! 2W! 41 mm 60 mm I victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/SO mm Max Hole 2751 mm Mm. Hole 17 mm Typical Ceiling Tile 30 mm 1 43 mm Finished Surface %x/ 3Onm MAXIMUM RECESS 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/SO mm Max. Hole Min. Hole 37 rnm 24 rnm 8mm Typical Ceiling Tile 24 nnnn Vinished Surface MAXIMUM RECESS - 2xA67 - 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 % 2014 Victaulic Company. All rights reserved. victaulic.com 4 jtauIic' Is' 3.om 8' 2.4m 4' 1,2m 2' 0.6m [8 11 56m 0 victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent uisirioution vaiterns - Irajectory 2' 4' 6' 8' 10' 12' 14' 0.6n, 1.2m tOm 2.4m 3.0r 3.7m 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory 2' 4' 6 8' 10' 12' 14' 16 0.6m 1.2m Is. 2Am 2Am 3.7,,, 4.3,,, 4.9, NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 5 'bJtauIic' 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock5 I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 F168 C 100 F/38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F8/107 C Blue Extra High 7 K 360 F/182 C 300 F/149 C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707V2708Pendent V2707, V2708 Recessed Pendent V2703, V2704 upright r - / AWARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: OWN 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in POE format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 JtauIic' Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's* Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPRQVEO [q4ONfA NFPA -J 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) 0.0. (IN) I.D. (IN) CRR** WEIGHT/FT WATER FILLED WEIGHT BUNDLE SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-114 1.660 1.442 : 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 776 209 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 11/4 1.660 1.380 1.00 227 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 100 3661bs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 T58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 'Only available in Casa Grande, AZ "corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO 6era14 MO KentWA (ace Grande. AZ Dallas, TX Masury, OH 63017 Dull Moose Tube's Eddythread 40 ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® U isa lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MlC preventative coating. EDDYTHREAD 40® SPECIFICATIONS c®us LISTED APPROVED C;]ONFSA NFPX NOMINAL PIPE O.D. I.D. WEIGHT SIZE (IN) (IN) (IN) CRR* LB/FT WATER FILLED BUNDLE WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3308 4.842 30 'Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masury, OIl 63017 5 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". EddyliteO is truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVED U;] NFSA NFPA' 6 ADVANTAGES OF BULL MOOSE TUBE® EDOYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. 'Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.1.6 431 2.617 4.230 37 *corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent,wA Casa Grande, AZ Dallas TX Masutt OH 63017 Dull Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® I) is specially engineered Certified to ASTM Al 35 and A795 Type F, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD Il® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs - and ease of handling. Furthermore, NIPS O.D. EDDY FLOWS EDDY FLOWS WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR* PER FT. WI. SIZE an opportunity for downsizing and further cost savings.1-1/2 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1.900 1.728 344 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 - -19 .Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED APPROVED no /4 ONFSA NFPX ---- For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grand AZ Dallas, TX Masutx OH 63017 7 Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® Li a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM'S requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR®® PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2.375 2.261 1.00 1.604 3.344 37 Pressfit is a Registered Trademark of Victaulic company of America Corrosion Resistance Ratio per latest UI Directory listing c®us LISTED <> APPROVED Ar— ONM NFPA -- 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ('® For Additional Information Contact (800) 325-4467 www.butImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent,wA Casa Grand AZ Dallas TX Masurij. OH 63011 c®us LISTED APPR8V NFPA •-- NPS(IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 0.0(i) 1.315 1.660 1.900 2.375 I.D.(iñ) 1.201 1.546 1.786 2.261 ULTRA EDDYO Empty Weight(lb/ft) 0.868 1.107 1.274 1.604 WaterFlfled Weight ljb/ft) 1.359 1.920 2.360 3.344 C.D.(in) 2.17 1.40 1.660 1.11 1.900 1.00 2.375 2.875 3.500 4.500 ID (in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty Weight(lb/ft) 1.222 1.844 2.330 2809 3 361 4.968 EDDY FLOW Water Filled Weight (lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 1.98 3.44 278 1.66 1.00 1.00 [ OD Cur) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1D.(jn) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Cnptyg/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 Water Filled Weight(Ib/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 [ C.R.R.1527 1.315 991 1.660 776 1.900 627 2.375 492 354 250 r LD.(mn) 1.137 1.482 1.712 2.177 EDDYLITE° EmptyWeight(mblft) 1.260 1.617 1.967 2.617 Water tiled Weight (mb/ft) 1.700 2.364 2.965 4.230 C.R.R. 0.13 0.08 0.12 0.16 - 0.0(m) - 1.295 1.650 1.900 2.375 r lD(in) 1.083 1.418 1.645 2.123 EDDYTHREAD 40e (mpt'jWeightOb/ft)_ 1.461 2.070 2.547 3.308 Water-Filled Weight (mb/ft) 1.860 2.754 3.468 4.842 C.R.R.- 100 100 100 100 00(m) 1.315 1.660 1.900 2375 2875 3500 4.500 I.D.(hi) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE EniptyWeight(mb/ft 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 WaterFilledWemght(lb/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R.100 100 100 100 100 100 100 i) A For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald. MO Kent WA Casa Grande, Dallas, X Masury, OH 63017 9 L ULTRA EDDY 0.868 91 SçHEDULE10 1.410 91 r EDDYLITE 1.260 91 EDDYIHREAD4O® 1.461 70 SCHEDULE 40 1.680 70 ULTRA EDDY 1.107 61 EDDY FLOW 1.222 61 SCHEDULE 10-' 1.810 61 1-1/4 EDDYLITE6 1.617 - - - - 61 EDDYiHREAD40 2.070 51 SCHEDULE40 2.270 51 ]ULTRA EDDY 1.274 61 EDDY FLOW" 1.844 61 SCHEDULE 10 2.090 61 1-1/2 , rEDDyLfl. * 1.967 61 EDDYTHREAD 40 2.547 44 SCHEDULE40 2.720 44 ULTRAEDDYt 1.604 37 EDDY FLOW 2.330 37 SCHEDULE1O 2.640 37 2 EDDYUTE 2.617 37 EDDYTHREAD40 3.308 30 SCHEDULE 40 3.660 30 1 EDDY FLOW . 2.809 2-1/2 Ir SCHEDULE 10 3.530 30 SCHEDULE 40* - EDDY FLOWS 5.800 3.361 L SCHEDULE 10 4.340 19 SCHEDULE 40* 1.EDDY FLOWO 7.580 4.968 4 [ SCHEDULE 10 5.620 19 SCHEDULE 4O SCHEDULE 10 10.800 9.289 10 8 j SCHEDULE 10 AZ. 16.940 7 - Only Available in Casa Grande, c®us LISTED APPROVE I;]ONFSA NFPA' ii,: 1,659 1,896 1,975 2,695 3,079 3,208 2,408 2,752 2,867 2,148 2,454 2,557 2,470 2,822 2.940 1,418 1,621 .: 1,688 1,565 1,789 1;864 2,319 2,650 2,760 2,071 - 2,367 2,466 2.217 2,534 2.639 2,431 2778 2,894 1,632 1,865 1,943 2,362 2,700 2,812 2,677 3,060 3,187 2.520 2,880 3.000 2,353 2,690 2,802 2,513 2,872 2,992 1,246 1,424 1,484 1,810 2,069 2,155 2,051 2,344 2,442 2,033 2,324 2,421 2,084 2,382 2,481 2,306 2,635 2,745 1,770 2,022 2,107 2,224 2,542 2.648 3,654 4.176 4,350 1,341 1,533 1,596 1,732 1,979 2,062 3,024 3,456 3,601 1,982 2,265 2,360 2,242 2,563 2,670 4,309 4,925 5,130 1,951 2,229 2,322 2,490 2,846 2,965 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings MaxZone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) ** According to HLF for the 2006 & 2009 IBC (ASCE 7-05 )& Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 401 37 1 34 1 32 1 0 1 9 128 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20 ft. 25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 H2221 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c) BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®ijs LISTED APPROV8I I;] - A-., NFPA' For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grand Daflas,TX Masury. OH 63017 11 MechanicaIT® STYLES 920 AND 920N STYLE 920 CROSS PATENTED STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a 'holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "I" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VIcTAULIC COMPANY. C 2017 VIcTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N Date \Lt2IUIjC 11.02_i DIMENSIONS pAN 0:--014~# GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psiI3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½'/50 x 15 Trim through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N ax. Work ressure@ Dimensions Approx. Weight Each Ms GM 0Q 177-1 2 ½ (a) a N 500 1.50 2.00 2.53 I 1,61 5.35 2.75 3.1 50 15 3450 38.1 51 64 1 ' I 41 136 70 1.5 - 1/4(a) a 920N I 1'-t- 500 1.50 1.97 --f--i- 2.53 f-I.-.--- 1.61 5.35 -1 2.75 3.1 20 3450 381 5064 - 411136 7O 11.5 1(a) a 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 j 64 - 41 136 70 1.4 - 1¼ (a) to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 .-3450 4i-i-- 44.5 52 70 76 41 136 76 ' 1.7 + 1.5 1½ (a) to 920N 500 1.75 2.03 -- 2.75 - 3 - .12 1 - .61 5 - .35 3.25 - 3 - .6 3 - .2 40 920N 3450 500 44.5 , 1.50 52 2.21 70 I 2.74 79 41 1.82 136 5.64 83 2.75 1.7 3.0 1.5 21/5 ½ (a( §a 65 15 3/4 (a) § a 3450 920N 500 381j 1.50 I 2.18 5670j 2.74 46 1.82 143 5.64 70 2.75 14 3.0 - 20 345 0 38.1 55 70 - 46 143 70 1.4 - 1(a) §0 920N ' 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 , - - - 3450 38.1 52 70 ± J.- 29 14 - 11/4 t (a) a 1 920N 3450 500 1.75 2.30 4455876l83 3.00 1 3.25 1.82 6.29 3.00 3.5 3.2 32 46 160 7611 15 1112 t (a) a 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 920N 3450 300 50.8L_~. 1.50 2.22 J ..i3 2.75 2.25 83 46 i4J 159 6.46 3.18 3.9 . 761 x 1/2 (a( 15 2065 38.1 56 70 - 57 164 81 1.8 - 1/4 (8) 920N 300 1.50 . 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 56 70 - 57 164 + 1(a) 920N 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 25 , 2065 381 53 70 j 57 164 81 11 3.00 1¼ (a) D 2 N 500 1.75 2.30 9 0 3.00 3.31 1.92 6.29 3.5 3.2 32 3450 j 44.5 58 j 76 84 49 160 76 1.6 1.5 _ 1 1h (a) a 920N 500 I 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 920N 3450 500 50.8 1.50 58 2.52 j 76 3.05 84 49 2.28 160 6.15 83 2.75 1.6 , 3.4 1.5 3 ½ (a) a 80X15 34503816478 58 156 70 1.6 3/4 (a) a 920N 500 1.50 2.49 3.05 I - 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 j, 58 156 70 1.6 - 1(a) 920N 500 1,50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 70 1.6 - 11/4 (a) to 920N 500 1.75 2.55 3.25 I 3.56 2.28 6.15 3.00 I 3.8 3.7 32(b) 3450 44.5 65 83 J 90 58 156 76 1.8 1.8 1140(a) t 920N ' 500 2.00 2.78 3.50 T 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 ,[ 58 156 83 1.9 1.8 2 (a) a 920N I 500 2.50 2.75 3,50 3.56 2.28 6.75 3.88 4.9 4.6 50 , 3450 500 63.5 2.50 70 3.00 89 90 3.75 58 172 2.44 1 6.72 99 3.88 2.3 2.1 3½ 2 3.8 2 N 0 90 3450 63.5 76 - 95 62 i 171 99 ' 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2017 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 .JtaUIiC REV_N DIMENSIONS IM lot 181 r GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½/50 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Pressure@ Dimensions Weight Each qSM AM ML JM TABLE CONTINUED FROM PAGE 2 4 1/2 (a) 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 f3450 38i 77 _20 68 178 70 18 I/- 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 7690 68 178 70i8 500 1(a) D 920 1.50 2.88 I 356 2.69 7.01 2.75 3.6 25 I 3450 38.1 73 - 90 68 j 178 70 1.8 - 11/4 (a) to 920N 500 1.75 .-+----j--)-4 3.08 3.78 1 4.00 t 2.69 ' 1 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 9L 102 68 2Z ]i 11/2 (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 4 102 102 1 68 178 83 2.0 1.9 2 (a) to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 4.6 5.0 50 63.5 83 102 1 102 68 2½ (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 ? 2.3 76.1 mm 920 1 2.75 2.88 - 4.00 2.69 t 7.34 1 4.63 - . 6.4 500 3450 69.9 1 73 1 102 68 186 118 2.9 3(a) t 920 500 3.50 3,31 4.50 4.12 2.69 t 7.73 5.12 8.4 6.4 80 I 3450 88.9 84 I 114 105 I 68 196 130 3.8 2.9 - 3.05 - 5.0 1080 x 11/4 (a)D 920N 500 1.75 3.08 3.78 2.63 I 7.64 32 3450 445 78 96 L. I 8 -. 1 ½ (a)a 920N 1 500 2.00 3.28 ' I 4.00 J 2.63 7.64 3.25 5.0 40 4 3450 50.8 83 - 102 67 194 83 2.3 3.25 2 (a) 920N 500 2.50 I 4.00 1 2.63 7,64 t 4.00 4 4.0 50 3450 500 63.5 2.75 83 2.88 102 1 - 67 2.63 194 102 1.9 - 76.1 mm 920 4.00 4.00 7.64 4.29 8.0 7.8 3450 69.9 73 102 1 102 67 194j10936 3(a) 920 500 3.50 3.31 4.50 1 4.50 2.63 7.63 4.88 6.8 6.5 80 920 j,,- 3450 88.9 2.00 84 4.03 114 + 114 4.75 4.75 67 3.16 194 9.70 124 3.69 3.1 7.4 3.0 ( 7.6 5 1½ (a) t I 500 125 40 3450 50.8 ( 102 121 121 80 ( 246 94 3.4 ) 3.4 ___ 2(a) t - 920 500 j 2.50 4.00 .--t_--t-t------t-.-1--i- 4.75 4.75 3.16 9.70 -. 4.38 8.2 8.0 50 -3450 63.5 102 121 JL 2½ (a) t 2.75 3.63 4.75 1 - 3.16 9.70 4.63 8.3 7.9 920 500 65 3450 69.9 92 1 1 I1 1i 9 246 118 3.8 3.6 761 mm c 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 6 95 121L80 j246 118j 3 3(a) t 920 500 ) 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 920N 3450 500 3450 ) 88.9 2.50 63.5 97 - 3.75 ,,__j 127 118 4.50 114 - -f --'t -±- 80 3.17 81 246 8.00 203 135 3.8 8.0 3.6 4.0 -. 1330 2 50 -- 3.88 I 99 3.50 1 3.81 9.46 5.31 8.0 500 s.00r TT 80 920 3450 88.9 97 127 - 76 I 240 135 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VicTAULiC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. A-Ctauha REV_N 11.02_3 GROOVED OUTLET CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Jl, FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½I50 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Dimensions Weight Each It I TABLE CONTINUED FROM PAGE 3 7 1'/2 t X N 500 2.00 3.78 4.50 - 3.30 8.23 3.25 7.0 - 40 3450 50.8 96 114 84 209 83 3.2 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 500 63.5 4 1.75 95 4.43 114 5.13 - 5.13 84 4 209 3.79 9.15 99 3.25 4.1 5.1 - 4.8 6 1¼ (a) 150 >< 32(b) 3450 44.5 112 130 130 96 232 83 1 2.3 2.2 1½ (a) 1' 920N 500 2.00 4.40 5.13 5.13 -+- 3.79 I 9.15 -t_. 3.25 I 5.4 5.1 40(b) 345058 112 130_13O 96i232 83 1 .... 23 2(a) 920N 500 2.50 4.38 5.13 5.13 3.79 1 9.15 3.88 I 6.0 5.6 50 3450 63.5 111 130 130 96 4 232 99 , 2.7 2.5 2½ 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 { 130 130 94 267 118 J, 3.8 3.4 761 mm r 920 500 2.75 4.15 I - 1 5.21 3.69 I 10.51 4.63 8.4 3450 69.9 105 132 94 267 118 ,j - 3.8 3(a) ' 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) t 920 500 4.50 3.81 5.75 j 5.38 3.69 10.51 6.25 10,1 10.1 100 34501143 920N 500 2.00 97 4.41 5.13 1461,137 I - 94267 3.63 9.40 1594 3.25 7.8 1590 1½ (a) 40 3450 50.8 112 130 .1. 9 _L2 .83 I ! -, 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 , 63.5 111 130 - 92 239 99 3.6 - 761 mm 3450 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 69.9 in 140 130 92 239 118 !. 920 500 3.50 4.31 5.50 5.13 3.63 1 9.40 5.31 8.1 14.0 80 34SO 88.9 110 140 130 92 239 135 3.7 6.4 1080 mm 920 500 4.50 4.45 T 5.38 3.63 9.40 6.12 10.0 3450 114,3 113 - 1 137 92 239 155 -4.5 920 500 4.50 3.81 5.75 3.63 1' 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victauliC.com \JtaUlic VIcTAuLIc IS A REGISTERED TRADEMARK OF vICTAuLIc COMPANY. © 2017 VICTAULIC COMPANY, ALL RIGHTS RESERVED. 11.02,_4 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2 /50 x 15mm through 8 x 4/200 x 100 mm OPO 1 "Ii _ TABLE CONTINUED 4 _FROM _PAGE 1 920 500 150 388 4.56 3.79 9.34 2.75 8.0 165.1 >< 25 3450 38.1 -4 99 I 116 - 96 237 70 3.6 -+-3 - 11/4 0 - 500 1.75 -- 4.43 5.13 3.79 - 9.34 3.25 8.4 32 3450 44.5 I 113 I 130 - 96 237 83 3.8 - 1½ (a) 'D 920N 500 2.00 4.41 5.13 5.13 3.79 - 9,34 3.25 3.4 5.4 40 .9.8 112 .1 9. . .1. 96 237 83 I 2. 2(a) 1' 920N 500 2.50 4.38 5.13 5,13 . 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 J! 130 i.9 761 mm 920 500 2.75 4.01 5.13 5.21 i 3.63 10.51 4.63 1 8.6 7.6 I69.9 110 130 132 92 . .L I J! 3.9 - 3(a)tø 920 500 3.50 4.31 5.50 5.13 . 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 .. 267 135 4.6 j 3.8 4(a) '' 100 920 500 t 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 920 ,3450 1 500 2.75 5.44 6.19 6.25 4.81 't 12.42 4.50 11.6 .L!.. 11.6 8 2(a) t 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 21/2 (a) t 920 500 - 275 1 -1 - 507 619 -. 619 481 -+- 1 1242 450- .- -1 1.6 I 11.6 65 9 I J I J . 5.3 761 mm a 920 500 3450,1 2.75 699 5.25 6.25 159j122316 4.81 12.42 4.56 ll. ii.5.3 11.6 3(a) to 920 500 3.50 5.31 1 6.50 6.50 4.81 12.42 5,31 i 12.6 11.6 80 3450 88.9 135 1 165 t 165 122 316 -- 135 5.7 -r-- 5.3 -. 4 (a) to 920 500 i 4.50 4.81 1 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 1 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China byTianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com vlClAuLlc IS A REGISTERED TRADEMARK OF vICTAuLIc COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVN ictsulie 11.02_5 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalT® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+160C are shown in the table below. Formulas for Values: C N1:2iG::1_ (1 AP =Q2 Where: p = Where: Q= Flow (GPM) Q= Flow (m3/hr) f \ P = Pressure Drop (psi) v P = Pressure Drop (Bar) U L.J J Q = x C= Flow Coefficient Q = K. x K2 = Flow Coefficient Exaggerated for clarity 120 I1uIIl14 Equivalent Length of 1 . I ILI M, amm '11, e1:LsI.1l4i C,/K, Value~s.:.j ½ 0.840 - 2 - 11 15 21.3 . 9.4 1.050 I 16 20 26.7 - 1 13.7 I j 1.315 3 8 1 - t 21 25 33.7 1.8 1¼ 1.660 5½ 6 50 i 48 32 42.7 42.9 1 41.1 1½ 1 1.900 11 53 53 40 98.3 j 45.4 1 2 2.375 101/2 112 104 50 . 0.3L 4 96 89.1 2 1/2 2.875 20 12'!2 119 150 65 73.0 102 128.5 76.1 mm 1 3.000 16 161 76.1 - 1381 - 3 3.500 14 15 ½ 249 237 80 88.9 213.4 203.1 4 4.500 20 22 421 401 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. 1 FireLock Innovative Groove System (IGS) outlet www.victaulic.com .,4'tauiicr vIcTAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 vICTAUUc COMPANY. ALL RIGHTS RESERVED. 11.026 REV_N CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 1i'1P $1I1Z jJ5I 21/2 - 6 2.875 - 6.625 All 40 400 400 400 290 232 1 1 362 65-150 73.0- 168.3 2.875 - 4.500 All Dr 2755 t -.-- 300 1 2755 300 2755 300 1 1999 290 1599 - 232 2496 -_-- 362 21/2-4 65-100 73.0-114.3 2.875 - 4.500 2065 300 300 2065_42065 1999 300 290 1599 232 2496 362 21/2-4 65-100 730-1143 6.625 All -- 34 SF - 10 2065 300 - 2065 i 300 2065 250 1999 290 1599 2496 232 362 6 150 83 6.625 34 30 40 2065 300 2065 1724 300 300 1999 290 1599 232 2496 362 6 150 168.3 2065 ---.----.,-_ 2065 2065 ---- 1999 ....... 1599 2496 8 8.625 21/2 10,40 400 145 200 2191 8.625 34 ..L 10 P.L---------- 300 - 250 _. - 1000 1 145 - 8 200 .. 8 25 .6 2.........................+.22_.~ 300 300 H99.°.. 145 .8 4 30,40 200 219.1 2065 I 2065 1000 - NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-I and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/345OkPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5'/125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 2½'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VIcTAuLIC COMPANY. © 2017 vIcTAuuc COMPANY. ALL RIGHTS RESERVED. REV_N 11.027 MechanicaIT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV UPDATED 12/2017 X/ictauliiie vicrAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L Fire Lock® STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade 'E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Pa ra Location Date Approved Date www.victaulic.com viclAuLic IS REGISTERED TRADEMARK OF vicruic COMPANY. 0 2000 vlClAuLlc COMPANY. ALL RIGHTS RESERVED. REV_G \4tauIcr 10.521 DIMENSIONS IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 Weight ¼ ½ 1 _ /16 __ 1.30 1.83 1.10 3.87 2.56 1.0 32 x 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 '/4 1 3/1 128 1.83 1.10 3.87 2561 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 , 1 1 1.52 2.18 1.10 3.87 " 2.56 1.2 25 30.2 1 3A6 , 38.6 1.42 55.4 1.95 27.9 1.22 98.3 4.08 65.0 1 2,56 . 0.54 1.2 1½ 1/2 40 15 30.2 35.1 1 49.5 31.0 103.6 65.0 0.54 3/4 11/161.40 3/4 1.95 1.22 4.08 2.' 1.2 20 30.2 35.6 49.5 31.0 103.6 55.0 0.54 1 13A6 1.64 2.30 1.22 4.08 2.55 1.3 25 30.2 1/ T 41.7 1.66 58.4 + 31.0 103.6 65.0 . I 059 2 ½ x 2,19 1.46 4.60 2.56 1.3 50 15 302 j,, 42.2 55.6 37.1 116.8 652 0.59 ,, '/4 13A6 1,54 2,19 1.46 4.60 2.56 1.4 20 30:2 41.7 ,j 55.6 37.1 116,8 65.0 064 , , 1 1/6 1.88 2.54 1,46 4.60 2.56 1.5 25 302 13A6 47.8 1.91 64.5 1 2.44 371 .L11 1,71 1 5,40 65.0 2.56 0.68 - 1,6 21/2 1/2 65 x 15 30.2 48.5 62.0 43.4 137.2 65.0 1 T 0.73 3/4 13A6 1.89 2.44 1.71 T 5,40 2.56 1.6 20 30.2 48.0 622 43.4 j137.2 55.0 0.73 , 1 1/i6 1 2.13 2.79 1.71 j 5.40 2.56 1.6 25 30.2 1 /6 1 54.1 1.91 70.9 2.44 43.4 1.71 137.2 5.50 65.0 2.56 0.73 1.6 ½ 6.1 mm X 15 30.2 48.5 62.0 43.4 139.7 I 65,0 I 0.73 - - 1•'- '--- + 3 4 1 1.89 2.44 1.71 . 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 J 65.0 0.73 ' 1 1/6 2.13 2,79 1.71 5.50 '1 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 11 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 'NJ taulicr REVG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com - - VICTAULIC IS A REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. tau1.c REV_G 10.52.3 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings EsipecificAtions branded ductile iron threaded fittings are UL Listed and FM Approved at 500 pi Rated to 300 WSP Ductile iron castings conform to ASTM A536 c®Lus LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B 16.14 <S> Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical prop ar ties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20t0100 500 500 480 150 200 250 460 300 440 350 -420 400 400 450 380 500 360 550 340 600 320 650 -- 300 C(9US APPROVED Fig. 35E 3_900 Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 1 - 35E 3006 35E 3010 1.31 70 140 80 0.3 0.5 1.50 40 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 - 20 1.8 - 2-1/2 35E3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in - Packing Weight lb Inner Master 3/4 x1/2 35RE3006004 1.20 1.22 - 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1 1/4 x1/2 35RE3012004 134 153 35 70 05 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 -1-1/4 x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1!2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F3 _450 Elbow I_I Size in Part Number A in Packing Weight lb Inner Master I 1/2 35F 3004 0.88 150 300 0.2 F 3/4 35F 3006 0.98 1.13 80 40 160 80 0.3 0.5 1 35F3010 iTi7ii 35F3012 1.29 25 50 0.7 I 1-1/2 35F3014 1.44 1 20 1 40 1.0 2 - 35F3020 1.69 10 20 1.6 1_2-1/2 35F3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-114 3513012 - 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2-1/2 2 _35T3020 2.25 6 - 1-4 12 2.4 35T 3024 2.70 8 4.3 1! 111 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1x1/2 35RT3010004 1.26 1.26 1.36 30 - _'60 0.6 1x1/2x1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35R13010006 1.38 . 1.38 1.45 25 50 0.6 1 x 3/4 x3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 - 35RT3010006010 150 145 150 25 50 07 - 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35R13012006 1.45 1.45 1.62 15 30 0.9 1-1/4x 3/4 x1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35R13012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35RT3012010004 1.34 1.26 1.53 25 50 01 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35R13014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35R13014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1!2x3/4x1-1/4 35RT3014006012 794 1.66 1.88 20 40 1.1 1-1/2x 3/4 x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 165 7.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35R13014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35R13014010012 1.82 167 1.88 12 24 1.2 1-1/2x1x1-1/2 35R13014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35RT3014012 1.82 182 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35R13014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35R13014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 115 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 2 x 11 35RT3014012014 35R13020004 1.94 1.88 1.94 14 28 1.4 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1,6 2x1 35R13020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35R13020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35R13020014 2.02 2.02 2.16 8 16 21 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 1 2.02 1 1.94 2.16 8 16 1.8 I@", <~> APPROVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x 1 1x11/4 35B13006010 1.45 1.45 1.37 30 60 0.6 356T3010012 167 167 158 20 40 09 1 x 1-1/2 35613010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x1x1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35B13012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35BT3012020 2.10 2.10 1.90 10 20 -1.6 - 1-112 x 1-1/4 x ? 1-1/2x2 35613014012020 2.16 2.10 2.02 10 20 1.8 35BT3014020 2.16 2.16 2.02 8 16 1.8 Iii SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35CP3004 1.38 200 400 0.1 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 - 35 25 70 50 - 0.5 0.7 1-1/2 35CP3014 2.19 2 35CP3020 2.62 - 15 - 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 111 Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35R03010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 - - 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 2x 1 (not hex) 35RC3020010 1 2.81 20 40 1.0 Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35HB3010004 1.06 180 360 0.2 1x3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35H63014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 - 80 0.6 2 x 1-1/4 35F-1B3020012 1.38 40 80 0.6 2x1-1/2 35HB3020014 1.38 - 40 80 0 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35SP3004 0.94 600 1200 0.07 35SP3006 - 1.12 350 700 0.1 - 1 35SP3010 1.25 200 400 0.1 1-114 35SP3012 1.37 100 200 0.3 1-1/2 - 35SP3014 - - 1.44 80 160 0.4 2 1 35SP3020 1.50 45 90 0.6 C- T Fig. 3503 - Straight Coupling with Ribs C@us<~> APPROVED LISTED Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 - Hex Bushing Fig. 35U3 - Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 - 35U 3012 2.50 15 30 1.2 1-1/2 3014 -35U 2.62 10 20 1.7 2 35U 3020 1 3.12 6 1 12 1 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com c®uS <> APPROVED LISTED Size ii Part Number U A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 2 35X3014 1.94 8 16 1.8 2.8 35X 3020 2.25 6 12 A A Fig. 3513- Cross 1j Size in Part Number A in Packing Weight lb I Inner Master 1/2 3503004 0.87 300 600 0.1 3/4 3503006 0.97 200 400 0.1 I 1 1-1/4 35C 3010 3503012 1.16 110 220 0.2 1.28 70 140 GA I 1-1/2 35C3014 1.33 50 100 7T-5- 2 35C3020 - 1.45 25 50 0.8i 2-1/2 3503024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp Fig. 35RX3 - Reducing Cross I Size I in I I Part A i in I B I i in I Packing I I Weight lb I I Inner I Master I 1-1/4x1 35RX3012010 1.67 I 1.58 I 15 30 1.2 I I1-1/2x_1 35RX3014010 _1.80 11.651 12 24 _1.4 I 2 x 1 - 35RX3020010 I_2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight I lb I Inner I Master 3/8 35B03003 0.75 1 100 200 0.3 I 1/2 35B03004 0.75 80 -160 0.5 SMITH-COOPER INTERNATIONALA • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 INSTALLATION STEPS -iiit1 INTO WOOD & STEEL: FSTALLATION STEPS -@iiIj!INTO WOOD & STEEL I. Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. Insert the SAMMYS" into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2' or metric all thread rod, bolt stock. (The 1/2"requires the #I4SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque 1020 foot lbs. for maximumpullout in purlin steel. hIE_A i 4! Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or boll stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque 1020 foot lbs. for maximum pullout in purlin steel. ~f 22, LZ Is INSTALLATION STEPS - %9OU-M INTO CONCRETE: Using an SOS 250 carbide tip bit ore HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#l4SWred nut driver used with 1/2'screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS .91ItINTO CONCRETE: Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member toe depth of 2" with a hammerl rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. EFIA1I1iIlEIkilliilI1lFU SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes Into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMYS FOR STEEL I Ii! p ed Made with TekO self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U.S.A. ....Mich a o demnsntlon at ViR www.iAvbulldex.com 114" 8024957 DSTRIOO 1/4720x1"TEKS3 1510 (20 ga.)- .036"-20 ga 3/16" 25 125 [ 1/4" 8025957 DST100 1/4-14 x 1"TEKS 3 446 (20ga) 036"-209a 3/16" 25 125 114" 8026957 DST 150 1/4-14x1-1/2TEKS3 970 (16 ga.) .036"-20 ga 3/16" 25 125 [ 1/4 8027957 DST 200 1/414x2TEKS3 446 (20ga) 03620983/16 25 125 1/4" 8030957 TEK 500 12-24 x 1-112" TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 3 '518 8038957 DSTRI 1/420 xl TEKS 3 1510 (20 ga) 1500 1475 03620 ga 3116.25 125 3 .c 3/8"8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 15001475.060"-16 ga. 1/2" 25 125 #14 Black 3' 3/88039957 DSTR5I6 5/16l8x11/4 TEKS3 2200 (LO 1500 1475 036 20ga 3/16 25 125 Pa 310 Nut Driver 3/8" 8040957 DST 10 1/4-14x?TEKS3 446 (20 .036"-20 ga 3/16" 25 125 3/8" - 8077925 DST 1SS 1/4.14 xl" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8041957 DST 15 1/4.14 x 1-1/2" TEKS 3 446 (20 .036-20 ga 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8042957 DST 20 1/4-14 x 2"TEKS 3 446 (20 ga.) 970 (1698.) .036"-20 ga 3/16" 25 125 [ 3/8" 8043957 DST 25 1/4-14 x 2-1/2" TEKS 3 446 (20 .036-20 ga 3/16" 25 125 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 446 (20 .036"-20 ga 3/16" 25 125 3 3/8 8045957 DST516 5/1618 x11/4TEKS3 1500 (3/16) 1500 1475 JT51/8 3/16 25 12] 3" 3/8" 8046957 TEK50 12-24x1-1/2"TEKS5 3125 (3/16") 1500 1475 .250"-1/4" 1/2" 25 125 - ---------- 446(2Oga) I [ l/T 8031925 DST 2.0 1/4-14x2"TEKS3 io(16ga:) ,186"-3/16 1 1/2"8033925 DSTRI.0 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 I i/2 8034925 0S1R516 5/1618x11/4 TEKS3 2220(20ga) 036__20ga 3/16 25 125 I 1/2" 8035925 DST 5.16 5/16-18x1-1/4"TEKS3 1500 (3/16") .125"-1/8" 3/16" 25 125 #14SWRed 1/2" 8036925 115K 5-6 12-24xI-1/2"TEKS5 3l25 (3/16") -, • 188"-3/16" 1/2" 25 125 - NutDriver '-- --- ----- .--------- -----------------------------•- ---• -•.-.-.•----.---.----- -- - .. - Part #8114910 includes retaining nut SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. fMOE $ USA Made with Teks® self-drilling fasteners - no pre-drilling required. 110 • Installs into steel range from 20 gauge - 1/2' thicknesses. - d \ • A standard screwgun with a depth sensitive nosepiece should be used to r eqUt e d install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. video Made in the U.S.A. WwwwitwhulldeX.COfl1J 1/4" 8047957 SWD 100 1/4-14 xl" TEKS 3 1477 (16 ga.) .060'-16 ga 3/16" 25 125 .iL.. SWDR 100' 11420x1"TEKS3 10C 9 L - Q36"-29 9a_ 3/16" 25 125 3/8' 8050957 SWD 10 114-14 x 1'TEKS 3 1477 (16 ga.) .060'-16 ga 3/16' 25 125 3/88080925_SW610SS 11414x1TEKS3 1477 (16 ga.) .06V-116 ga 3/16 25 125 3/8" 8051957 SWD 15 114-14 x 1-1/2" TEKS 3 1471 (16 ga.) .060-16 ga 3/16' 25 125 - 3/8' 8052957 SWD2O l/4-14x2' TIE 'KS 3 1477 (169a.) .060.l6 ga 3/16' 25 125 3/8' 8053957 SWD 516 5116-18 x 1-1/4" TEKS 3 2480 (20 ga.) .036"-20 ga 3/16' 25 125 JQL 3/8 80557_WpR1 1/420x1 TEKS3 1900 (20 ga.) 1500 1475 .036%20 ga 3/16 25 125 #14 SW Red 4€' 3/8' 8054957 SWDR 1-1/V 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .188'-3/16' 1/2" 25 125 Nut Driver 3/8 8056957 SWDR5165/16 18x11/4 TEKS3 2480 (20 ga) t5q0 1475 .036%2 ga 3/16 25 125 Part#8114910 - 3/8" 8057957 SWT15 12-24x1-1/2'TEKS5 2375(3/16") .188-3116' 1/2" 25 125 Includes retaining nut I IIPihi SWIV EL HEA D' FOR S TEE L Swivel 1IDiva Application Product Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-pudin; allows threaded rod to hang plumb. "Allows 17° deflection from vertical. "Made in the U.S.A. Approva is Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thick Thick Qty City Nut Driver .1 4' 3/8" 8137957 SH-DSTR 1 3220(3/16') 1500 1475 .035" 3/16' 25 125 Part#8ll39lOL . 2368(1/2' steel Vertical) 3/8" 8268957 SII- TEK 50 12-24 x 1-3/4" 1306(45° off Vertical) 1500 (Vertical) ' 3/16• 1/2" 25 125 TEKS 5 2281 (3/16' HSS) 850(45° off Vertical) 2-1/2' 1585(3/16' HSS 45 off Vertical) 2368(1/2' steel Vertical) 1/2" 8270957 Sl1-TEK5.O 12-24x1-3/4" 1306 (45 off Vertical) 3/16' 1/2' 25 125 #14 SM Orange 1585 (3/16 1455 45 off Vertical) Nut Driver - - Pan /I 8273910 "Does not comply with ROHS requfremen!s/lncludes retaining nut S A huM V X- P R E S 5 Installs into Metal Deck, Purlin, or Tubular Steel "The Sammy X-Press expands to provide direct vertical attachment in: - tight gauge steel deck or purlin (22 ga. - 1/8"). Installs in seconds with Sammy X-PressIt" Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor baffler fabric. Less jobsite material needed. No retaining nut required. 'Provides design flexibility. Made in the U.S.A. kVIatch a veo clwww.i1wbuildex.comJ 1/4" 8181922 XP 200 Sammy X-Press 200 J. <> 3/8" 8150922 XP 20 Sammy X-Press 20 3/8" 8153922 XP 35 Sammy X-Press 35 185 (Luminaire) 1146 (229a) .027" .125 25 250 (Luminaire) 056' 850 (2W Pipe) .027" 1146 (22 ga) 185 (Luminaire) 250 (Luminaire) .02'r .056" 1475 (4' Pipe) .104' .125" 25 283 (Conduit & Cable) .029" 1500(4" Pipe) .060" 1783 16 185 (Luminaire) .029" 940 (2" Pipe) .029" 125" 25 250 (Luminaire) .056" 1475 (4' Pipe) .104" 416 (Conduit & Cable) .059" 125 Metal Deck 125 Metal Deck 125 Pudin r Pre-Pour Structural Concrute@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy1146(229a) 850(2%Pipe) 25 125 L X-Press 20 Pont-Pour Range II LWC:5 35 PCF (lbs/it') Metal Deck (Post-Pour) Pre-Pour Structural Concrete @3000 pal Post-Pour Range It LWCS 35 PCF (thai ft') The SidewinderX-Press expands to provide horizontal attachment in: - 16 ga - 3/16" steel - purtin, tubular steel. "Installs in seconds with Sammy X-Press le Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof I ESWXP) deck, tubular steel, or vapor baffler fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. "Made in the U.S.A. a monsraton at wwwltwbuikiex.com jitr 545.3551 aWXl'i5 X-Press35 no (Lumnare) MT s is llumn L ... .. for jefll0 of ant iuO pitch es 4T 2AY1SI The Swivel X-Press allows you to hang plumb in extreme roof pitches: - 89° in z-puilin 45° in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press le Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Mich a Wdwdamonxtixlnal 0=0www.1fwbu11dex.coMj 750(2" Pipe) - ' 3/8" 8294922 SXP 20 Swvel 170 Vertical (Luminaire) 1061 (22 ga Vert) 80 @45" (Luminaire) .029" 635 (2" Pipe) .029" .125" 25 125 Metal Deck X-Press20 283 Vertical (Conduit & Cable) 233 @45° (Conduit & Cable) 1250 (3-1/2' Pipe) 3/8" 8295922 SXP 35 SvAvel 1675 (16 ga Vert) 250 Vertical (Luminaire) 059" .029° .125" 25 125 Puilin X-Press35 635 (2" Pipe) 1558 Off Vert) 500 Vertical (Conduit& Cable) 333 @89° (Conduit & Cable) 1/2' 8272957 SXP 2.0 Swivel 0 1061 (22 ga Vert) .027' .125" 25 125 Metal Deck Swivel 1675 (16 ga Veil) 1/2' 8271957 SXP X-Press 3.5 1558(89° Off Vert) AT .125" 25 125 Purtin The Sammy X-Press expands to direct vertical attachment in: metal deck (22-16 gauge) z-pudin (18-16 gauge) provide Made in the U.S.A. 0*0 Watch a dam ftWn at Part Number Model Description Qty [ 8194910 UXPFF Universal X-PressR Tool - 8152910 XPDB 25/64 Drill Bit 1 Ixol Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/84" Drill Bit. APPROVALS 3007957 3S1 10 3/8° Vertical CPVC 1-1/2" 300 1-1/2" 9020957 SWG 10 3/8' Horizontal CPVC 1-1/2" 300 1-1/2" 3008957 3S120 3/2" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 3068925 3ST20-SS 3/8" Vertical 2-1/2" 850 1-1/2" 3010957 GST3O 3/6" Vertical 4" 1500 1-1/2' 4 1475 1-1/2" 3009925 3ST 25-380 3/6"" Vertical 4" 1500 1-112" 3022925 SWG 25-380 3/2" Horizontal 3-1/2" - 4"" 1500 1-1/2" 3021957 SWG 20 3/€" Horizontal 2-1/2" - 3'** 1050 1-1/2" 3073925 SWG 20-SS 3/€" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 450 Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 450 Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8° 17° Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" I 8038957 DSTR 1 3/8' Vertical 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/€" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 3045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 3046957 IEK5O 3/2" Vertical 4" 1500 .250" 4° 1475 .188" 3055957 SWDRI 3/2" Horizontal 4" 1500 .037" 4" 1475 .060" 3056957 SWDR 516 3/2" Horizontal 4 1500 037 4 1475 060 3054957 SWDR 1-1/2 3/2"" Horizontal 4" 1500 .037" 4" 1475 .060" 3137957 SHDSTRI 3/8" 17 Angle off Vertical 4 1500 035 4 1475 105 8268957 SH-TEK5O 3/8" Vertical 2-1/2" 850 70" Angle off Vertical 4 1500 3150922 XP 20 3/8" Vertical 2-1/2" 850 .027' 2 940 .029 3153922 XP35 3/8" Vertical 4" 1500 .060" 3294922 SXP 20 3/2"" Vertical or up 10450 2" 750 .027" 2" 635 .029" 3295922 SXP 35 30 Vertical orupto89" 3-1/2" 1250 .060" 2" 635 .029" 3293957 SWXP3S IF Horizontal 3-1/2" 1250 .060" I SAMMYS FOR CONCRETE - PIPE HANGER 8059957 05120 3/8" Vertical 4" 1475 3000 3061957 SWC2O 3/8° Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 9150922 XP 20 3/8' Vertical 2-1/2" 850 Post-Pour Range II LWC 5 35 PCF (lbs/ft3) 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027" 45" 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060" 90° 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" i : UIL Steel Listed Application 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8' Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 027 Max 4 trade size EMT RMC and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 3293957 SWXP 35 3/8" Horizontal 500 060 Max 4 trade size EMT & 6 trade sze RMC IMC and rigid PVC conduit 3149957 CZ2000 1/4" or 3/3" Onto Vertical Rod UL Listed 4S16- Cable Hanger, Cat. No. -Z2000 Plenum Rated, Complies w/ NEC Standards Sheet Steel 1Gauges Gauge No. 229a. 209a. 18ga. 16ga. 14ga. 12ga. 1181" 3116" 114" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250' "SWO 25-380 Munimum pipe size in composite wood joist stowed by Ut. is 3-112" UL compliance with NEC Standards SWG 25-380 Mtdmurn pipe size in wood Umber or joist allowed by Ut. is 4" Ut. and FM texts were performed in compliance with NFPA13 Standards. \NG 20 M conum pipe Size ti flOOt V/ldJt521I2" Fastening requirement 5 times weight of water-tilled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037') or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at w.itwbuildex.com Sammys for Seismic Please visit w.itwbuildex.com for our current Seismic product offerring. Vibratory Environments, For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: fModel RootI]R1T Hole Size GST 20 .182" 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA!NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings / FM Approvals UL and FM reports are available at www.itwbuildex.com PWEHMiGER UOUflOAICOIWUrTNCCA8LIK*PDtInI ALsQL1tDA3mcHoRLtftm,AmE -'I Technical Drawings Technical drawings are available and can be downloaded at w.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products GOMM _ Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.2 Material specifications KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listings/Approvals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor ILA( DBS FM APPROM Indenendent code evaluation IBC®/ IRC® 2015 IBC®/ InC® 2012 IBC®/ IRC®2009 IBC®/ IRC®2006 a1 Huh, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter db, in. 1/4 Nominal embedment h00, in. 1-5/8 2-1/2 Effective embedment het in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque ___ T. nt ______________ ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 T, is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size da 1 - J - fanch - he hnom h0 dbt Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2'3'4'5 Nominal Nominal Tension - cpN,, Shear - qV anchor embed. f',=2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f' 2,500 psi f',=3,000 psi 1',, 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2'3'4'5 Nominal Nominal Tension - Nn Shear - anchor embed. f', = 2,500 psi f', = 3,000 psi f', = 4,000 psi f', = 6,000 psi f' = 2,500 psi f', = 3,000 psi f' = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, Ac = 0.68; for all-lightweight, X. = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a,,,,,, = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - a,,4,, = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile3 Shear4 Seismic shear' diameter thread diameter qN,, in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1 /4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension 4N pAf,, as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with <0.64A,, f as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with 5 0.60 A v f,,,, as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espafol 1.800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 1. toward edge from edge factor in shear4 uncracked concrete 'AN 'RN 'AV fRI I NV 1HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a f 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a -- 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 g 5 (127) _______ 0.93 _______ _______ 0.80 0.70 _______ _______ _______ _______ _______ 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 75 7 (178) 0.92 0.78 1.00 8(203) 0.98 0.82 9 (229) 1.00 0.86 10(254) 0.89 CO 11(279) 0.93 12(305) 0.97 - 14(356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete1'2 Edgedistanceinshear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 cracked concrete 1AN 1RN 1AV 1RV 'NV 'HV_______ Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnw (mm) (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2(38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2(51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3(76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4(83) 0.96 1 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2(89) 0.99 1 0.80 0.71 0.64 0.76 0.92 n/a 4(102) 1.00 0.85__ 0.74 0.66 0.93 0.98 n/a 4-1/8(105) 0.86 0.75 0.66 0.97 1.00 0.81 CO 4-1/2_(114) 0.89 0.77 0.68 1.00 0.85 5(127) 0.93 0.80 0.70 0.89 Cn co 5-1/2(140) 0.98 0.83 - 0.72 0.93 6(152) 1.00 0.86 0.74 0.98 7 (178) _______ _______ _______ _______ 0.92 0.78 _______ _______ _______ _______ _______ 1.00 CD 8 (203) 0.98 0.82 9(229) 1.00 0.86 10 (254) _______ _______ _______ _______ _______ 0.90 _______ ___ _______ 11 (279) 0.94 12 (305) 0.98 1 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, IAV assumes an influence of a nearby edge. If no edge exists, then fv = fs 4 Concrete thickness reduction factor in shear, INN' assumes an influence of a nearby edge. If no edge exists, then I NV = 1.0. EJ If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 33.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck1'2'3'4'5'6'7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Shear - qV Tension - qN Shear - On anchor thread embed. f',= 3,000 psif'= 4,000 psiJ'= 3,000 psif'= 4,000 ps f',= 3,000 psif',' 4,000 psif' 3,000 psif', 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal intern Nominal Tension - (pN Shear - Tension - 4N Shear -On anchor thread embed. f' 3,000 psi f= 4,000 psi f',= 3,000 psi f',= 4,000 psi f',= 3,000 psi f',= 4,000 psi f'= 3,000 psi f'= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 / 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h0,,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,s = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanoI 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 1; 1 Mechanical Ancho ring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Mm. 3/4" Minimum 20 gauge steel deck (typical) Mm. 1-1/4" IVifi I. IC LyJII.OI) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACl 355.2 for mechanical anchors and ACl 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I N carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile' Shear4 Shear' diameter diameter Nsa, V r V req in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N r = A N 'Ps f1 R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with Vsar < A554 4 0.6 f A as noted in GSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with v r <A4 4) 0.6 f R as noted in GSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800.879-5000 1 Hilti (Canada) corp. 1-800-363.4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 Ii Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.314 Anchor O.D. d8 in. 1/4 (mm) (6.4) Effective embedment' h f in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 h in. 1-5/8 2-1/2 nom (mm) (41) (64) Minimum concrete thickness 4-1/8 h in. 3-1/4 (mm) (83) (105) Critical edge distance in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance Smincac in. 1.5 (mm) (38) Minimum edge distance Cmin in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 I (mm) (51) (73) Minimum specified ultimate strength f.a psi 125,000 (N/mm2) (862) in2 0.045 Effective tensile stress area A SeN (mm2) (29.0) Steel embed. material resistance factor for reinforcement 42 - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 lb 3, 370 Factored steel resistance in tension N D.6.1.2 (kN) (15.0) lb 750 Factored steel resistance in shear V D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic Vsareq (kN) (1.5) lb 725 Factored steel resistance in shear Vsar D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V sar,eq (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete Fc - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete kc.cr - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 tpcN - 1.0 D.6.2.6 Anchor category - - 1 D.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete6 Nprunc, lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) lb 340 815 Factored pullout resistance in 20 MPa cracked concrete6 Np,,, D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete6 Npreq 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with GSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by GSA A23.3-14 Annex D section D.2. For all design cases, tcN = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k00r) or uncracked concrete (kccnc) must be used. For use with the load combinations of GSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with GSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qj = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure 1+1 in uncracked concrete' 2,3,4,5 Nominal Tension - N __________ __________ Shear - V f' = 20 MPa f'c = 25 MPa f' = 30 MPa f'c = 40 MPa f' = 20 MPa f' = 25 MPa I = 30 MPa f' = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure W in cracked concrete' 2'3'4'5 Nominal Tension - N Shear - V __________ 10 = 20 MPa f = 25 MPa 1', = 30 MPa f'c = 40 MPa f', = 20 MPa f', = 25 MPa f', = 30 MPa f' = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) Iq 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, k = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800.879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,1,6,7 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - IN Shear - V Tension - N Shear - V, anchor thread embed. I' = 20 MPa f, = 30 MPa f = 20 MPa Pc = 30 MPa f' = 20 MPa f', = 30 MPa f = 20 MPa f = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2.3,4,5,6,7,8 H Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N, Shear - V Tension - Nr Shear - Vr anchor thread embed. f = 20 MPa f = 30 MPa f, = 20 MPa f = 30 MPa f', = 20 MPa f' = 30 MPa IC = 20 MPa f = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x hnom (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,CeC = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor - a. = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 - 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en españoli -800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete Danels1'2 Hanger rod size Min. effective embedment h in. Allowable load3 Ultimate load Tension lb Shear lb 4,5 Tension lb Shear lb 4,1 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in hollow core concrete 3.3.7 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 13/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espahol 1.800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 314" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8 1, 1/21 and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California OSHPD Approved c YL us usito Seismic Restraints System Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1A6 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1/ie 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 .1 CUSTOMER SERVICE • 800.786.5266 wwwoIco.com Fig. 25 - Surge Restrainer c®US LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 - COOPER B-Line Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved c@ us USTED Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100- All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions . Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. CORONA, CA 92879 P11: 951.137.5599 FAX: 951.731.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com B 4 - A •. / Fig. 200_1/2. 200-I4 Fig. 200-1 to 200-2 Fig. 200-2/2 to 200-8 Fig. 200 Fig. 200S Ix !If ii -ii •• ;• Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) ØOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut C®us LISTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel .1 -. materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Q 200-1/2 1/2" (15) I8"-16 31I8" (79.4) 2I8" (66.7) 11 (5.0) 200-/4 3/4' (20) /8"-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200_11/4 11/4" (32) /8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-1/2 11/2" (40) I8"-16 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 (50) I8"-16 41/21 (114.3) (76.3) 15 (6.9) 200-21I2 21/2" (65) /8"-16 5/8 (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 57/8' (149.1) 4" (101.6) 29 (13.3) 200-3I2 31/2" (90) /8"-16 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 1 3/8"-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5' (125) 1/2"..13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"13 101/8" (257.2) 6I4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"13 131/8" 1 (333.4) 8I4" (222.2) 136 (62.3) All dimensions In charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200_21/2 to 200-8 1'- -peiJfiairgeis VOLCO c®Us USTED Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe - Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe.j_- (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig 200-1 to 200-2 Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel I J materials will be supplied with (2) hex nuts / in place of a knurl nut. / ) Order By: Figure number and pipe size I' ç J Designed to meet or exceed requirements of FM OS 2-0. Mal la I) : ) .t1 •.• i1i) (flj 200M8-1/2 1/2" (15) M8 31/8 ' (79.4) 2/8" (66.7) 11 (5.0) 200M10-1/2 1/2" (15) M10 31/8 ' (79.4) 2/8" (66.7) ii (5.0) 200M8-3/4 3/4" (20) M8 31/8' (79.4) 21/2 ' (63.5) ii (5.0) 200M10-3/4 3/4" (20) M10 31/8 ' (79.4) 21/2 ' (63.5) ii (5.0) 200M8-1 1" (25) M8 3I8" (85.7) 2/8' (66.7) 12 (5.5) 200M1-1 1" (25) M10 3I8" (85.7) 2/8' (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8' (73.0) 13 (59) 200M10-11/4 1/4" (32) M10 33/4" (94.0) 2I8' (73.0) 13 (5.9) 200M8-11/2 11/2" (40) MB 3I8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3I8" (98.4) 2I8' (73.0) 14 (6.4) 200M8-2 2" (50) M8 4I2" (114.3) 3' (76.3) 15 (6.9) 200M10-2 2" (50) M10 4I2" (114.3) 3' (76.3) 15 (6.9) 200M-21/2 21/2' (65) M10 5I8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8' (149.1) 4' (101.6) 29 (13.3) 200M-3112 31/2" (90) MiO 7I8" (187.3) 51/4' (133.3) 34 (15.6) 200M-4 4" (100) M10 7 /8' (187.3) 5' (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 1 8" (200) M12 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. .•..' COOPER B-Line 11511 IML Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8'-16 or 1/2"_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 11111 11111 JB •. 200H-2-3/a 2' (50) /8"-16 4/16" (115.9) 3/32" (81.7) 48 (21.8) 200H-2-1/2 2° (50) 1/2"..13 423/32° (119.8) 3/8" (85.7) 45 (20.4) 200H-21/2-3/8 21/2" (65) /8"-16 5/1" (134.9) 323/32° (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200II-3-I8 3° (75) /8"-16 53/4" (146.0) 327/32 (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"13 5/8" (148.1) 331/32' (100.8) 60 (27.2) 200II-4-/8 4" (100) I8°-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4" 1 (100) 1 1/2"13 71/32° (178.6) 419/32' (1116.7) 1 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified r . . .. ....- ' . COOPER B-Line PROBES as kel Lu b!a n St ]TTONL F P P I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ' System Compatible Program* Certified to NSF/ANS/Std 61 -G FBCV.. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. L i] 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX+ 1800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. Nu © 2012 Fire Protection Products, Inc. FPPI°, LubeFit5 are registered trademarks of Fire Protection Products, Inc.bA FGG/BM/CZ, Blaze-Master", FlowGuard Golcl° and Corzan5 are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. LjxW 9J F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. I 3198 LIONSHEAD AVE I CARLSBAD, CA 92010 I TEL + 1760 599-1168 . + 1 800 344-1822 1 FAX +1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling 8f the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com © 2012 Fire Protection Products, Inc. FPPI®, LubeFit5 are registered trademarks of Fire Protection Products, Inc. FBC', B1azeMaste,', FlowGuard Gold'5 and Co,zan'5 are registered trademarks of Noveon IP Holdings Corp. Spears® Compatible indicates that ThreadFft® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. 4 jh!ad!GL!!rladeuftl!il! Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Nu © 2013 Fire Protection Products, Inc. FPPI®. ThreadFUO are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBC/:9A SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CALS8AD, CA 92010 TEL + 1760 599-1168 +1800344-1822 -. FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300.