Loading...
HomeMy WebLinkAbout6155 EL CAMINO REAL; ; FPC2016-0039; Permitof (City PERMIT REPORT Carlsbad Print Date: 03/02/2022 Permit No: FPC2016-0039 Job Address: 6155 EL CAMINO REAL, CARLSBAD, CA 92009-1602 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 12/19/2016 Valuation: $0.00 Lot #: Issued: 01/10/2017 Occupancy Group: Project #: Finaled Close Out: 02/22/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASATTEC DATA AREA NORTH SSA LAB EXPANSION -FIRE ALARM TI Applicant: FPContractor: iii ENTERPRISES THE STEINHILBER CORPORATION SALOMON GOMEZ 533 S VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x216 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov F-FC-2- 0V mfvfvp EH7Ep'ppwEo FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS VIASAT TEC DATA AREA NORTH SSA LAB EXPANSION 6155 EL CAMINO REAL CARLSBAD, CA 92009 FIRE ALARM SYSTEM MATERIAL DATA SHEETS BILL OF MATERIALS HEELOCK EXCEDER SERIES - STROBE, HORN STROBE NOTIFICATION APPLIANCE CSFM#: 7125-0785:0168 Save up to 48% in current draw* :- Up to 9 models now in 1 appliance,-' - Save up to 14% cost of installation" Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB 2g 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 to ceiling - 15/30/60/75/95/115/150/177 ub Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types COOPER Notification EXVEnND0%R_ Strobe, Horn Strobe, and Horn Notification Appliances Description: The Wheelock ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelocka ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederlM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Environmentally Friendly Low current Draw Compatibility and Requirements - Synchronize using the Wheelock' Sync Modules or panels with built-in Wheelock" Patented Sync Protocol - Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range "Compared to competitive models * Patented Compared to previous models NOTE All CAUTIONS and WARNINGS are identified by the symbol A) All warnings are printed in bold capital letters A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS, General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32"F to 120"F (O"C to 49"C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low LCurrent 'Strobe Ratings per UL Standard 1971 lli PA'Fewer Power Supplies UL Max Current* 24 VDC /24FWR 12VDC Model Regulated Voltage r§( RangeVDC 15/75 30 60 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 80330 O6) 0.085 0.103 1615 - 0.182 - 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC UL Max Current* at Anechoic 99 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 . 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0,242 0.282 0.125 ••• EAnechoic 95 dBA I •••• 24VDC 12VDC Model Regulated 15 15/75 i3 60 ('7 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 10.073 0.083 0.087 0.139 0.163 0.186 . 0230 0.272 0.122 0.153 H'C 80330 0073 IO"5 0.128 139 0.163 0.186 0.230 0.272 0.122 UL Max Current* at Anechoic 90 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 135 150 177 185 15 15/75 ange VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0,157 0.1841 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 Jo 184 ft226 0,267 0.120 Horn Ratings per UL Anechoic - - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies HSR 15/1575/30/75/95/110/135/185 X X UMB** HSW 15/1575/30/75195/1101135/185 X X UMB** HSRC 15/30/60/75/95/115/150/177 X X UMB** HSWC 15/30/60/75/95/115/150/177 X X UMB** STIR 15/1575130/751951110/135/185 X X UMB* STW 1511575130175195/1101135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** STWC 15/30/60/75/95/115/150/177 X X UMB** X X UMB** q HNR HNW - X X UMB** HNRC X X UMB** HNWC X X UMB** NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. S Architects and Engineers Specifications The notification appliances shall be Wheelock ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HNAudibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and SIC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wail Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/I1 Cooper Notification is Wheelock (MEDCJ SAFEPATH WAV #0 COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover©cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDCIFWR Candela (wall)*: 15,15/75,30,75,95,110, 135& 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Copyngflt 2015 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and download on January 21, 2015 to JJJ ENTERPRISES for designated user PETE CAMEJO. No other reproduction or transmission in any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact licensing@nfpa.org. 'p DOCUMENTATION 72-37 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record, Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 3/9/2017 Supplemental Pages Attached: I 1. PROPERTY INFORMATION Name of property: ViaSat Address: 6155 El Camino Real, Carlsbad, CA 92009 Description of property: Business Name of property representative: Address: Same Phone: - Fax: E-mail: 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: JJJ Enterprises Address: .11..5...Mar.ket street - Escondido - CA - 92029 Phone: (760) 747-3050 Fax:________________________ E-mail: Service organization:..... Same as above Address: Phone:..________________________ Fax: __________________________ E-mail: Testing organization: same as above Address: - Phone: Fax:_ Effective date for test and inspection contract: Monitoring organization: Address: Phone: Account number: Phone line 1: Means of transmission: Entity to which alarms are retransmitted: E-mail: E-mail: - Phone line 2: - Phone:_._..,_. DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system Modification to existing system Permit number:160039 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: Notifier 4.2 Software and Firmware Firmware revision number: v3 4.3 Alarm Verification Number of devices subject to alarm verification: © 2012 National Fire Protection Association FIGURE 7.8.2(a) System Record of Completion. (SIG-FUN) Model number: NFS640 )ui This system does not incorporate alarm verification. Alarm verification set for _________ seconds NFPA 72 (p.1 of 3) 2013 Edition 15.1 Copyright 2015 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and download on January 21, 2015 to JJJ ENTERPRISES for designated user PETE CAMEJO. No other reproduction or transmission in any form permuted without written permission of NFPA. For inquires or to report unauthorized use, contact Iicensiflg@nfpa.org. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120vac Control panel amps: 3 Overcurrent protection: Type: breaker Amps: 20 Branch circuit disconnecting means location: Main electric Room Number: PM&. JI P C7 5.1.2 Secondary Power Type of secondary power: Batteries Location, if remote from the plant: N/A Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit U This system does not have power extender panels 3 Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line N/A B 0 Device Power - N/A Initiating Device N/A B 0 Notification Appliance 1 B 0 Other (specify): REMOTE ANNUNCIATORS Type Location N/A Main Lobby INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 0 Smoke Detectors 0 Addressable Duct Smoke Detectors 0 Conventional Alarm Heat Detectors 0 Gas Detectors 0 Waterflow Switches 0 Conventional Alarm Tamper Switches 0 Conventional © 2012 National Fire Protection Association NFPA 72 (p.2 Of 3) FIGURE 7.8.2(a) Continued 101 2013 Edition Copyright 2015 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and download on January 21, 2015 to JJJ ENTERPRISES for designated user PETE CAMEJO. No other reproduction or transmission in any turin permitted without written permission of NFPA. For inquires or to report unauthorized use, contact Iicensingnfpa.org, DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 0 Visible 2 Strobe Combination Audible and Visible .. .. 1 horn/strobe SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 0 HVAC Shutdown 0 Fire/Smoke Dampers 0 Door Unlocking Elevator Recall 0 Elevator Shunt Trip 0 Ceiling Fan Shutdown Relay 0 INTERCONNECTED SYSTEMS This system does not have interconnected systems. Li Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS or 12.1 System Installa n&K11 This system as sp ifie en installed according to all NFPA standards cited herein. Signed: Printed name: Steve Overholt Date: 3/9/2017 Organization:_JJJ Enterprises Title: Project manager Phone: (760) 747-3050 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Same as above Printed name: Date: Organization: Title: Phone: 12.3 Acceptance Test Date and time of acceptance test: .3VZ0I A Installing contractor representative: Testing contractor representative: Property representative: AFIJ representative: © 2012 National Fire Protection Association NFPA 72 (p.3 of 3) FIGURE 7.8.2(a) Continued 2013 Edition Copyright 2015 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and download on January 21, 2015 tO JJJ ENTERPRISES tordesignated user PETE CAMEJO, No other reproduction or transmission in any form permitted without written permission of NFPA, For inquires or to report unauthorized use, contact icenstng©ntpa.org. DOCUMENTATION 72-45 NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is supplement to the System Record of Completion. It includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record, Insert N/A in all unused lines. Form Completion Date: 3/9/2017 ,__.. Number of Supplemental Pages Attached: 0 PROPERTY INFORMATION Name of property: Viasat Address: 6155 El Camino Real, Carlsbad, CA 92008 NOTIFICATION APPLIANCE POWER EXTENDER PANELS Make and Model Location Area Served Power Source Notifier FCPS-24S6 1st Floor Elect.rm. 1st floor 120vac See Main System Record of Completion for additional information, certifications, and approvals. © 2012 National Fire Protection Association NFPA 72 FIGURE 7.8.2(d) Notification Appliance Power Panel Supplementary Record of Completion. (SIG-FUN) 2013 Edition