Loading...
HomeMy WebLinkAbout5541 FERMI CT; ; FA120013; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120013 Job Address: 5541 FERMI CT Permit Type: FALARM Parcel No: 2121305000 Lot #: 0 Reference No.: PC #: Status: PENDING Applied 3/14/2012 Approved: Issued: Inspector: Project Title: ADIDAS TAYLORMADE T.I. Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: FERMI COURT L P 1800 THIB000 RD #320 VISTA CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 257 0 257 0 WPISES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS TAYLORMADE ADIDAS GOLF 5545 FERMI COURT CARLSBAD, CA 92008 FIRE ALARM SYSTEM DATA SHEETS VISTA-100 Flexible Fire/Security Combination Control Panel' Integrated Systems can incorporate commercial wireless, addressable and conventional wiring' , r ADEMCD An ADEMCO Group Company VISTA-100 Control Panel The VISTA-100 is a Commercil Fire and Burglary Alarm Control interfacing with Access Control to provide complete protection of life and property. The Vista-1 00 now features Keypad programmable function testing for its V-Plex (addressable) commercial photoelectric detectors. The alarm control offers eight partitions in a UL Listed Commercial Fire and Burglary control panel supporting up to 87 zones/points using hardwired, compatible wireless devices and V-Plex (addressable) technologies. It also supports initiating and notification circuits, digital dialers, keypads, RE receivers and relays. In addition, the control supports scheduling capabilities. Defined operations can be automated by pressing a single keypad button to enable user defined macros. The VISTA-100 is available in 12V and 24V models. Key Features Eight zones standard expandable to 87 zones/points Eight partitions 150 user codes, 224 event log capacity + Two on-board notification (bell) circuits delivering 2.3A at 12V or 3.4A at 24V (optional) Supports in excess of 1,000 two-wire smoke detectors 4 Seven authority levels 4 Temporal Code Compliant 4 Supports UL268 Listed commercial wireless smoke detectors Supervised dialer-circuit Event logging storàge,p1int;i' ndretrieval 4 Automatic scheduling.featç.ies 4 Easily programmed and maintained through Compass WindowsTm based software 4 Programmable auxiliary Form C relay 4 Hardwired, wireless and V-Plex (addressable) technology 4 Uses existing wiring for retrofit appliations Mechanical: Cabinet dimensions: 4 18"H X 14.5"W X 4.3"D Environmental: Storage temp: + -10°C to 70°C Operating temp: 0°Cto50°C Humidity: 4 85% RH EMI: 4 Meets or exceeds the following requirements: 4 FCC Part 15, Class B Device . 4 FCC Part68 4 IEC EMC Directive Agency Listings Burglary: 4 UL609Grade A Local Mercantile Premises and Mercantile Safe and Vault UL611/1610 Grades A, AA, Central Station UL365 Grades A, AA Police Connect Fire: UL864/NFPA72 Local, Central Station and Remote Station *.Factory Mutual (Pending) 4 California State Fire Marshal MEA UL985 3RD1JP COMMERCIAL SYSTEMS DIVISION I .- FAM An ADEIVICO Group Compa t11 1111 Ordering Information Part No. Description VISTA-100 Commercial Fire and Partitioned Burglary Alarm Control VISTA- Commercial 100-24 Fire and Partitioned Burglary Alarm Control 24V Model COMPATIBLE DEVICES, See ADEMCO Group control accessories compatibility chart for complete list Auxiliary devices: 6139R - red alpha keypad/anninciator + 514ODLM - backup dialer module 5140LED - LED annunciator module 4204 - relay module, four form C contacts 4204CF - two supervised output circuits 4 5881 EH - RF receiver supporting 5800 wireless detectors 4 6220S - system printer used With 4100SM serial module Two-wire smoke detectors conventional: 4 2100 Series Photoelectric 4 2400 Series Photoelectric 1100 Series Ionization lour-wire smoke detectors onventional: 0,0 2112/24 Series Photoelectric 4 1412 Series Ionization Horn/Strobes: 4 System Sensor Notification Appliances Manual pull stations: 4 514OMPS Series +MPS-5 V-Plex (addressable) devices: 4208U Loop Expansion Mddule - eight zohes 44101 SN Single Relay/zone ridule 4 4209U Group Zohing Module td/fourzbnes \ 4 4190WH Remot Point Module- two zones 4 41935N Two Zone Serial Interface Module 4 42935N One Zone Serial Interface Module 4 42085NF Eight Zone/2 Class A/6 Class B Expander module 4 4297 Isolation/Extender Module V-Plex (addressable) Smoke Detectors: 4192 Series 4 5192 Series Passive infrared detectors: 998MX 4 4275EX 4 4287EX-SN V-Plex (addressable) Contacts: 4 4194WH 4 49395N 4 49445N 4 49595N Glass break detectors: +7500 49500 Optional 2IV power supply PS24 - 24V power supply - 3.4A Long range radio: 4 7720 - Long range radio Software: 4 Compass Downloader - Windows compatible Wireless devices: 4 5804BD - Bi-directional key 4 5808 - Wireless smoke detector 4 5808C - Wireless smoke detector without sounder 4 5809 - Wireless heat detector 4 5816 - Door/window transmitter 4 5804 - Wireless key 4 5827BD - Bi-directional keypad 4 5890-PIR 4 5849 - Glass break detector 4 5819 - Shock sensor 165 Eileen way, Syosset, New York 11791 • Copyright© 1997 Pittway Corporation A. D EMC D ADEMCO is an 1S09001 Registered Company FR cj i...i I= LNIS100/D Rev. 1/99 COMMERCIAL SYSTEMS DIVISION APPLICATIONS The VISTA-100 control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating and control devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, supermarkets, churches or synagogues, office buildings, schools, universities, strip malls, and factory or warehouse environments. INSTALLATION The VISTA-100 alarm system has been designed to mount both quickly and easily in an attack resistant cabinet, It meets all applicable requirements for UL commercial Fire and Burglary installations and is NFPA72 compliant. SPECIFICATIONS - Electrical: Primary power - 120VAC to ADEMCO No. 1451 Transformer Secondary rated 18VAC. 72VA Quiescent current draw: —350mA Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) Alarm power. - 12VDC, 1.7A max for each notification (bell) circuit output Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) Alarm power - 12VDC, 1.7A max for each notification (bell) circuit output Aux' standby pwr - 12VOC, 1A max Total power. - 2.3A at 12VDC. 3.4A at 24V0C from all sources Standby time: —24 hours with 1A standby load or 60 hours with 205mA max standby load using 34.4AH battery Fusing: - Battery input. aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Main Dialer Line seize: -_ - Double Pole - Ringer equivi: —0.78 Formats: - ADEMCO Low Speed. ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescou and Radionics 4297 2.25 ICY z-i <Y 5192 SwIss 55,5kb 05,5db, 4192 , vista-lw ME ADEMCO An ADEMCO Group Company ''5.. ADDITIONAL FEATURES Notification Appliance Circuits (Two) - Programmable —Temporal code compliant - Individually silenceable Programmable on-board auxiliary relay SIA false alarm reduction features: - Exit error Ionic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report + Supports hardwired, V-Plea (addressable) polling loop and wireless zones Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.O or N.C. sensors - Individually assignable to one or all eight partitions - Up to 16 two-wire smoke detectors on zones one and two (32 total) - - Four-wire smoke or heat detectors on zones one In eight - Up to 511 two-wire glass break detectors on zone eight Patented V-Pies (addressable) polling loop technology - Supports up to 120 two-wire multiplex zones/points - Can use existing wiring - Global polling technology for faster processing - Increased current draw capacity )128mA( - Individually assignable to partitions. notification circuit (bell) output or ass relay - 4,000 It capability without the use of shielded cable - Extender/isolation bus module - Two-wire smoke detector zone/group expansion module adds two or four zones - Eight zone - Class A and B extender module - Eight zone - Class B extender module - One zone supervised contact monitor module UL Listed wireless smoke detector expansion - Supports up to 87 wireless zones u'sing 5881 receiver - Supervised by control for check-in signals - Tamper protection for transmitters - Individually assignable up to eight'partitions - Supports UL864/NFPA listed/c nplaint wireless smoke detectors Scheduled uploading of events to central station - i 00 TAYLORMADE ADIDAS GOLF 5545 FERMI COURT CARLSBAD, CA 92008 FIRE ALARM SYSTEM BILL OF MATERIALS HONEYWELL 4I0ISN ADDRESSABLE RELAY MODULE CSFM# 7030-1645.-0147 HONEYWELL 41935N INTERFACE MODULE CSFM# 7300-1645:0127 1-, 21 L 4101 SN An ADEMCO Group Company Addressable Relay Module FEATURES The ADEMCO 4101 SN V-Plex Single Output Relay Module is an accessory for use with ADEMCO control panels that support serial number addressable polling loop output devices. The 4101 S features the following: + Form C relay contacts rated at 2A, 28VACNDC with contact supervision. The position of the relay is supervised, but not the actual external contact wiring. Note: Some panels may not support this feature. + One class B/style B EOLHsupervised aux input zone. Operating power and communication with control panels via the addressable V-Plex polling loop. Electronics mounted in a small plastic case with tamper-protected cover. Suitable for residential and commercial burglary and fire installations. SPECIFICATIONS Physical: Width: 2-1/8- (53mm) Height: 3-1/4 (84mm) Depth: H (25mm) Electrical: Polling loop input voltage range: 8-14VDC addressable polling loop current draw: 7mA (continuous) Relay contact rating: 2A © 28VAC/VDC, both resistive and inductive loads Aux Zone: + 10k EOLR (internal when white jumper intact: external when white jumper cut) + 300 ohm max zone resistance (excluding EOLR) + Responds to open or short circuit fault having 250mSec or longer duration 0 Class B (style B when used with panels providing earth ground fault detection) AGENCY LISTINGS UL985 Household Fire UL1023 Household Burglary, UL609 Commercial Burglary UL864 Commercial Fire + CSFM (pending) 0 FM (pending) + MEA (pending) MOUNTING INSTRUCTIONS Remove the case cover by first removing the screw. Fasten the case back to the wall with three #6 screws (not supplied) through the case back. (See Figure 1. on back page) The wall surface must be flat and substantially vibration-free. WIRING INSTRUCTIONS 1. Run the wiring through the access slots in the case back and connect at the appropriate terminal block screw(s). ADED C3FRDLJF COMMERCIAL SYSTEMS DIVISION CL 'CD An ADEMCO Group Company EERIE ASSIGNMENT LO I.) POLLING LOOP I') (I ).) WILING OP ).) I• JX ZONE ,> MOUNTING RELAY lEO. I CASE BACK ' IT RELAYNC. IT RELATE TEFRVINAL BLOCK TB> (SUITABLE FOR 14.22 AWG WIRE) POLLING LOOP OTHER TERMINALS ON VPtEX OULES CONTROl. POLLING LOOP ALWAYS OBSERVE POLARITY. ALWAYS CONNECT IN PARALLEL SEE PM4EUS I.I. TEXT FOR WIRE GAUGE AND WiRE LENGTH REOSIREMENTS. Figure 1 Ordering Information Part No. Description 4101SN V-Plex Single Output Relay Module 2. Make wiring connections as shown (in Figure 1 on back page). When you leave the white jumper intact, the 10k [OUR for the aux zone is internal only. N.O. devices may be used, and these devices must be mounted no farther than 3 feet from the module. In commercial installations, wiring must be mechanically protected with conduit or equivalent. When you cut the white jumper, you must connect the 10k EOLR for the aux zone to the end of the zone wire run. Either N.C. or N.C. devices may be used, and these devices may be located where desired. When the aux zone is programmed for burglary response type, you may use the discrete 10k resistor (supplied). When this zone is programmed for fire response type, you must use the model number WA 610-13 resistor (supplied). 3. Place the cover over the PCB and insert the screw to hold it in place. PANEL PROGRAMMING INSTRUCTIONS The 4101SN Module's serial number must be enrolled in the control panel so that the panel can communicate with it. Each 4101 SN (if there is more than one connected to the addressable polling loop) is enrolled one at ame. The following steps outline the general procedure mu imw ui's is done. Refer to the control panel's Installation Instructions for additional information. Enter the panel's Programming mode. Enter Zone Programming mode. 'G Assign a unique zone number and a non-zero zone response type to the 4101 SN. This zone willbe used to annunciate aux zone faults, communication problems, and cover tamper faults for this 4101 SN. o Select Input Type = "06" (for serial number polling loop device), V-Plex Relay = "Yes" and Loop#= "1" for this zone. Select the Learn S/N = "Yes" option. Remove the enclosure cover (or short the aux zone) to cause the 4101 SN to send its serial number to the panel. The panel will acknowledge receipt Qf,the,,serial number and will require the cover to be replaced (or the aux zone to be çestpred)to confirm that the serial number was enrolled correctly. The cover tamper feature must be used in commercial installations when the 4101 SN is not mounted inside the panel's enclosure, and must be enabled at the control panel (program field '24=0 on most controls).3. Enter Relay Programming mode. '0 Assign a unique 2-digit relay number 'XX" and then assign relay start/stop activation options to the 4101 SN. Select Relay Type = "0" (for V-Plex relay) and then enter the zone number selected in Zone Programming as the VPlex Zone Number. The panel willl annunciate relay activation problems as well as communication problems and cover tamper faults for this 4101 SN on system zone 6XX where 'XX" is the selected relay number. Generally, the panel's default response for all such system zones is 24-hour trouble (type 19). If desired, this may be changed using the panel's Zone Programming mode. Repeat the above procedurefor each 4101 SN in the system. 165 Eileen Way, Syosset, New York 11791 • Copyright © 1997 Pittway Corporation ADEMCO is an IS09001 Registered Company C) Li I L/4101 SN/D 1/99 COMMERCIAL SYSTEMS DIVISION UI COLA (USE ONLY IP WHITE JUMPER ISCOT) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7030-1645:0147 Page 1 of 1 CATEGORY: 7030 -- EXTINGUISHING SYSTEMS LISTEE: HONEYWELL SECURITY2 Corportate Center Dr, Suite 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@honeywell.com DESIGN: Model 4101SN-XX multiplex single zone expander and relay module. The suffix -XX indicating enclosure color. This module is an accessory for use with ADEMCO 's listed fire alarm control panels. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-14 VDC (Polling Loop) 28 VACNDC (Relay Contact) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as control unit accessory for use with, listee's separately listed compatible fire alarm control unit. NOTE: Formerly 7300-0078:198 10-28-2010 JC r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: MIKE TANAKA, Program Coordinator Fire Engineering Division HOME ABOUT US PRODUCTS SOLUTIONS fi SERVICES SUPPORT & RESOURCES Control Expansion Wireless Alarm Life Panels Keypads Modules & Products Communications & Sensors Sat ety Accessories Total ConnectTM ZBRIDGE Honeywell Security & Communicatior Expansion Accessories Sounders/Strobes 41 S3SN ' Quick Links Product Literature Intrusion Integrated Security Video Surveillance Access Control Cabling & Custom Electronics NIJ 4ACS 4 Security NEWS & EVENTS CONTACT US Structured Cabling Demo Kits Wiring Products Kits F~ Product Search Search by product name AutoCAD Drawings 41B3SNDWC Micro-miniature two-zone VPloxTM adapter Makes any hardwired contact device VPIexTM ready Built-in serial number for addressing One supervised zone and one unsupervised zone UL listed fire and burglary applications Product Literature ) Back to Top - For product-specific literature, see list below. For related marketing materials, click here. Expansion & Accessories for Residential & Commercial Control - UL UO)(X Listing Sheet V-Plex Addressable Technology V-Plex Family - Scalable Solutions Download Terms & Conditions I Privacy Statement I Site Map © Copyright Honeywell International Inc 2004-2012 91 You 3 ACE •3 ur0 4 SOF. 4 Product Online Matrix Learning /.; •, Honeywell DESIGN PROMOTE: CONTACT US STAR ONLINE System System Vertical System Submittals & Overview Cornponenis Solutions --Applications Listings X. PRIS Set Interface Modue for Addressable Detection Description and Purpose Iinrijce Modue is a device that creates an eddessabie zone input for a :3:\ nntiune ctetection pevice It otters a connection to a naudrossable eus. and a m!oeiesee zone input When the crone input is open, the module sends status data to :!zer5üi mnei inuicafing the open position. When the zone input is shorted, the sterus ontO to the control panel, indicating the shorted condition When 1 c :e•.rn Is nnnnal. the nrodjse sends data to the control panel, indicating the ,)jM,ad cc c ci5tc15 are marina from the sensor at the local The coQtrQLQg5i 1 3 lo lho nroctitnririq tctio1. 5cc a! !'tsetac'c Mcr:1cie can ha irsed in Intrusion Detection, Fire Alarm. Ar n 'or c Systems B ri oincj C ontror, and in Eliey ,_i!9n12ge1flEfl1 applicatiorrr.r Reasons to Choose this Sensor i;,e S,n rc : irerface Module provides some important advantages The module ( _S 1 .rOu'OS .!3tOl' eiinn a"'lor cy its special designBy providing an addressable zone / \ / 'put usne This rocuie d anratically reduces the overall cost ot Inc entrre system. Inca ire :tbinrtriit OvOCLiSO the rroouie's ClaM cable need not he .1'. or mc :o tOil zmctr 0! panel The cable is an addressable bus that allows .nrci:i0,t' cc •:.r . yv,'r/S tretore cahlrrro and .mnnr. trip to Inc conilrul panel for IV, :0, :: 10 ri cvotscted 3:1ii!lsl ti5in5CntS, helping too nodule to ovei come voltage Figure 1: Routing the Oko 1:2ev m,rin:'cns:c ci msccnnectrons V-Plex Bus to the Serial I....: ecshe ho sac np ,cerrect, and mrnmzes the need for additional power supplies Interface Module. ' Of us cm ci ment eq1uianienm Connections and Considerations I c a3.2' he'oW rrIais to tne drawing rI Figure 'I It you are rising thrs docurrtent on line, click fire rrtortel numoer in :1 cl i :.1nv ft. ccc 122cr nfcnii it an row MadI No. Description Mounting Options Actaoter: Serial Interlace Inside of monitored Muirlo device. V °:VQE V-Ple.X71.1 Data Gus mrS 1.1 AWG Fire Use Genesis 1118 for riled. Non a ierded Nun-Fire Apoiicationis Notes Allows any conventional device with relay output to become an addressable device Connects to addressable devices, zone input devices and relay modules. This part number is an example. See your building and electrical codes for actual jacketing requirements. Design Considerations Incur' ilcO srcrci ones: the detection dnrvie-a or sensor inside of the protected area -1 r.r,r 'to' r,j:,rnsd 00010 from the control panel locaI;on, or froin the nearest V-Pies device to the module It more an U........0 srcurc rne,led, coirrnuo ruLirp Inc V c "Ilex DLi5 on to atlrvr device iocatrons Let us Help Web Site iy imcnnec'cvei! 00cr !rcoi utiori 55 odes 0 ti I rnic.l 3uaperr Phone: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION WkS OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0127 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corportate Center Dr, Suite 100, Melville, NY 11747 Contact: lssa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawadhoneywell.com DESIGN: Models 4193SN Serial Number Interface Module (SIM) and *4190SN 2-Zone Expansion Module. The modules are accessories for uswith Ademco fire alarm control panels supporting polling loop devices. They are intended to be connected to the control unit's polling circuitry and provide point identification for devices which are provided only with a set of dry contacts. Model 4193SN and *4190SN must be installed within the control panel cabinet or inside a UL listed enclosure. For fire alarm, the supervised zone must be used. Refer to listees data sheet for detailed product description and operational considerations. RATING: 12VDC,3mA INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use only,with Ademco's separately listed fire alarm control units. NOTE: Formerly 7300-0078:178 10-28-2010 JC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: MIKE TANAKA, Program Coordinator Fire Engineering Division