Loading...
HomeMy WebLinkAbout6185 PASEO DEL NORTE; 110; FPC2021-0153; PermitPermit No: FPC2021-0153 CARLSBAD, CA 92011-1152 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Status: Closed - Finaled Applied: 08/17/2021 Issued: 09/07/2021 Finaled Close Out: 12/27/2021 Inspector: Final Inspection: PERMIT REPORT Cr'city of Carlsbad Print Date: 12/27/2021 Job Address: 6185 PASEO DEL NORTE, # 110, Permit Type: FIRE-Construction Commercial Parcel #: 2110401800 Valuation: $86,271.76 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: SIMONMED IMAGING -SPRINKLER TI (7 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ANTONIO ROSARIO 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843-SAN DIEGO (760) 295-3436 (619) 306-6926 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $553.00 FIRE Reinspection (per Inspection) $212.00 Total Fees: $765.00 Total Payments To Date: $765.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 I 760-602-85611 I www.carlsbadca.gov ML M Protection Contractor - License #989280 OPIER PROTECTION FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 21781 SimonMed Imaging Carlsbad 6185 Paseo Del Norte suite 110 Carlsbad, CA 92011 Page 1 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'JIKI 4 l:IIEu.yM SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 ZtWARNING: cancer and teprcdscftve Harrn wwwP65Warnngsca.gov () VdS Approved: Certificate G4080021 LPCB Approved: Certificate number 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending .cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SsJ I K] 4 lIE.q1uqM.. SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G1 0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 OF (68 "C) = B, 175 OF (79 "C) = D, 200 OF (93 °C) = E For example, sprinkler VK463 with a 155 OF (68 "C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 OF (57 °C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 OF (74 °C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availbie with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 OF (57 °C) UL (139 "F (59 "C) FM and LPCB) = A, 165 OF (74 "C) = C For example, cover 21876 with a 165 OF (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 "F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2' ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731 A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3 of 7 MIRAGE® STANDARD AND El Arm QR CONCEALED PENDENT SPRI NKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1SPRINKLER TEMPERATURE RATINGS ANDJIlFI:l* Sprinkler Sprinkler Maximum Nominal Ambient Temperature Rating of Cover Cover Plate Large Cover Square Cover Temperature Temperature Ceiling Assembly (Required) Base Part Plate Base Part Plate Base Part Bulb Color Classification Rating' Temperature Number' Number' Number' Ordinary 155 °F (68° C) 100 °F (38 °C) 135 °F (57 °C) cULus 13504 or 218761 13642 or 218755 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 13504 or 21876 13642 or 21875 5 15394 Yellow Intermediate 1 200 °F (93° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 2187511 15394 Green Cover Plate Finishes5: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings": ENT Footnotes l The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. EX) All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers I Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 MIRAGE® STANDARD AND NIKI QR CONCEALED PENDENT 4 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) SprnkerTempeature RaUg Cover Rate TemperatureRo Miragee Concealed Pendent Sprinklers VK462 and VK463 AW1* Cover Plate Foh KEY Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Inch mm U.S. meti1c2 cULus' I NYC I Vd57 LPCB (( 12 Base Part No.' Pressure Standard Response Applications 13503A VK462 1/2" -- 5.6 80.6 175 psi (12 bar) -- -- AY1, CZI AYI, BZI AY1, CZ15 AY3 -- 19785A VK462 1/2" -- 5.6 80.6 175 psi (12 bar) -- -- - -- -- -- AY2, CZ2 21356A VK462 - 15 5.6 80.6 175 psi (12 bar) -- -- - -- -- -- AY2, CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AV1, BX16 - - -- AY3 -- AS3, BT3 AV1, BX1, 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX16 - - -- -- -- AS3, BT3 13667A I VK463 1/2" 15 5.6 80.6 1 250 psi (17.2 bar)3 1 AV1,BX1 I AV1, BX1 I -- -- -- -- -- Cover Plate Assembly Temperature Ratings',9 Sprinkler Temperature S - 135 OF (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Ratings I - 165 OF (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155°F (68 °C) V - 135 OF (57 °C) cULus Listed cover 13504, 13642 (large Brass, Brushed Brass, Brushed Copper, Painted White, diameter), or 15394 (square cover plate) B - 175 OF (79 °C) and 200 OF x - 165 OF (74 °C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 °C) Y - 135 OF (57 °C) cover 13504 LPCB Approved as 139 OF 2 - Brass C - 200 °F (93 °C) (59 °C) 3 - Stainless Steel Z - 165 OF (74 °C) cover 13504 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. I Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8 CE Certified, Standard EN 12259-I, EC-certificate of conformity 0786-CPD-40249. The 135/139 OF cover has an orange label. The 165 OF (74 °C) cover has a white label. IS Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. 12 MED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F103005 18.10.11 Rev 18.2.P65 Page 5 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT \iIKJ 4 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA -UL (Also refer to Approval Chart 1) - cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Aøoroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN 12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 6 of 7 JII(I MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) SpKt,re'r'peutureRat Rate Cover Temperature Rt` Mirage Standard Response Concealed Pendent Sprinkler VK462 AW14 Covet Pate F °sh KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals' Part No.' I SIN I I Water Working I (Refer also to Design Criteria below.) Inch I mm I U.S. I metric2 I Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AW1, BX1, AY2, BZ2 Cover Plate Assembly Temperature Ratings1'4 Cover Plate Assembly Finishes' Y - 139°F (59 °C) cover 21875 or 21876 Sprinkler Temperature Ratings z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175°F (79 °C) and 200 °F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 7 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT N41KING4 I:IIE.iu.rM SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap Sprinkler Wrench removed ' - Part No. 14047WB** Use wrench 14047WB** - Step 1: Carefully slide the wrench sideways around the deflector and pins 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise Ito 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) ler arms Sprinkler wrench fla 2-3/4" (70 mm) or 3-5/16" (84 mm) NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation 1/2" (15 mm) NPT 2-9/16' Ma -1/16" (52 mm) Minimum Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 N II (ING® MICROFAST® QUICK 4 l.4IIEUqM RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 () LPCB Approved: Certificate 096e/06 WARNING: Cancer and Reproductive iarm- wwP65Warnings.ca.gov CE CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart I and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar) Approvals ONLY is 5 psi (0.35 bar). The minimum operating pressure for LPCB and CE Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 ¶ (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F 033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap— Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 19.02.21 Rev 19.1 Page 3 of 6 N 1 K] MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color U o or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. .t 7 Sprinkler wrench 13655W/B** for rec sprinklers essed pendent ** A 1/2" ratchet is required (not available from Viking) *4 Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 19.02.21 Rev 19.1 Page 4 of 6 N I AWM 8 MICROFAST® QUICK l:II[.u'JIv. RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) The Viking Microfast Quick Response Temperature KEY Pendent Sprinkler VK302 IA_ Escutcheon (if applicab!e) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K.Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric- Inches mm cULus4 VdS LPCB ((7 8 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, BIY D1Z, C1Y Dl -- 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 - -- -- -- -- D3 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 1 2-1/4 58 lAlZ,BlYI)2,C2XI -- -- -- 18021 VK302 I Pendent 1/2" 15mm 5.6 80.6 1 2-1/4 58 A1X,B1Y Al I A1X,131Y I DlX,C1Y7 Dl -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 °F (57 °C), 155 "F (68 "C), 175 °F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 °C), 286 "F (141 "C) Polyester", Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B -135°F (57 °C), 155°F (68 °C), 175 °F ter56 V - Standard surface-mounted escutcheon or recessed with the Viking Micromatica (79 °C), and 200 °F (93 °C) 2 - ENT' Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 °F (68 °C), 175 °F (79 °C), and 3-Chrome Z - Standard surface-mounted escutcheon 200 °F (93 °C) D -155°F (68 °C), 175°F (79 °C), 200°F (93 "C), 286 °F (141 "C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-50021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - _UL (Also refer to Approval Chart I above.) cULus Listing Requirements: The Viking Microfast Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 5 of 6 NIKI Fs1G MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfasta Quick Response Frsh Pendent Sprinkler VK302 A1X+- EscttcheonPa2J Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 1 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 ¶ (79 °C), 200 °F X - Standard surface-mounted escutcheon or the (93 °C), 286 ¶ (141 °C) Approved Finishes Viking Micromatic® Model E-1 Recessed B - 135 °F (57 CC), 155 °F (68 CC), 175 °F (79 CC), and 1 -Brass, Chrome, White Polyester', Escutcheon 200 ¶ (93 °C) and Black Polyester4 Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 ¶ (79 °C), 200 F (93 °C), 286 2 - ENT5 with the Viking Micromatic® Model E-1 or E-2 °F (141 °C) Recessed Escutcheon D - 155 °F (68 °C), 175 F (79 CC), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 6 of 6 '1 IKIF1G®MICROFASTO QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT A -•-- , 4 ,v. i... (4 5 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-1/8".... '17I (54 mm) I + 1-3/4" (45 mm) Max. Iu'ø- 2-1/8" —. - .—.—L (54mm) .. t (29 mm) 2" Mm. (5;m) Ma - + 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) BulL Moose Tube's° Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube* made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tub&sa Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. Eli SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE OLD'. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHTIFT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9,91 1,81 lbs/ft 2.518 61 1-1/2 11900 1.682 7.76 2,09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 334 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS - - -- -- - - NOMINAL PIPE OLD. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.049 1.00 1.68 lbs/It 2.055 70 1.380 1.00 2.27 lbs/ft 2.918 51 1.610 1.00 2.72 lbs/ft 3.602 44 2.067 1.00 3.66 lbs/ft 5.114 30 2.468 1.00 5.80 lbs/ft 7.875 30 3.068 1.00 7.58 lbs/ft 10.783 19 4.026 1.00 10.80 111s/9t 16.316 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembIy causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 (iarkson Road thesterflektMO GesaklM0 Kent WA CasaGIandeAZ Da1X MaS(40H &LNttCNY 63017 'I 1.315 1-114 1.660 1-1/2 1.900 2 2.375 21/2* 2.875 3* 3.500 4* 4.500 Oftaaabfe In cs Grande,AZ -Cowc6on Resistance Ratio per latest UL D4rectoty Listn 16 IITILWAE1Q3 Ijl E EIIaEazEJiE 1JJ E] Bull Moose Tube'sP Eddythread 4010 ADVANTAGES OF BULL MOOSE TUBE° EDDVTHREAD 400 is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of I. e Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings. couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM'S requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. EDOYTHREAD 400 SPECIFICATIONS -- - -- --- I NOMINAL PIPE 0.0. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* - LBJFT - - WEIGHT SIZE 1 1.295 1,083 1-114 1.650 1.418 1-112 1.900 1.654 2 2.315 2.123 FtesMantr Ratio per latftt UL Drectwy Ltinc 1.00 1.461 1.860 70 1.00 2.070 2154 51 1.00 2.547 3.468 44 1.00 3.308 4.842 30 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gast pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A For Additional Information Contact (800) 325-4467 wwwbuIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U l8l9ClaiksonROM chtfektMo Geraki,MO Kent,WA CasaGrandeAZ Dallas,IX Mas4uOH 63017 5 EI!H!YLITE® THE SUPERRR LIGHTWALL THREAIABLE Dull Moose Tube's°Edd4ite°is ADVANTAGES OF BULL MOOSE TUBE° EDDVLITE° I) a Iightwalt threadable pipe • Standard outside diameter, unlike some other lightwafl threadable pipe products. manufactured in NPS 1 through • Lighter in weight than Schedule 40. 2. Eddylite° is a truly unique • Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products.. product within the fire protection • Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. industry. • Can be used with standard couplings, fittings, and valves. Freight savings. This product has been engineered • Lower sprinkler system costs without compromising service life. to provide lower cost fire protection • Better hydraulics than Schedule 40. systems without compromising • Wall thickness and weight close to Schedule 30; compare to other lightwali threadable water tilled products with wall service life, adequate wall thickness, thickness less than Schedule 10! or standard outside diameter. Eddylite° is manufactured to meet CORROSION RESISTANCE RATIO (CRR) - the requirements of ASTM Al 35 NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE and A795 specifications. This pipe PIPE SIZE (IN) 0.0. (IN) DIAMETER (IN) THREADED UNTHREADED PER Ft FILLED SIZE product has been fully approved by Factory Mutual, and listed by 1 1.315 1.137 0.13 7.47 1.260 1.700 91 Underwriters Laboratories (for 1-1/4 1.660 1.482 0.08 4.79 1.611 2.364 61 U.S. and Canada) for use in tire 1-1/2 1.900 1.712 0.12 4,53 1.967 2.965 61 protection systems with a working 2 2.375 2.177 0.16 4.31 2.617 4.230 37 pressure of 300 psi or less.Res6tx"per Iatet UL Dkectay Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasbet pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED For Additional Information Contact (800) 325-4467 www.bullrnoosetube.com [] it, ONFM Or From Canada Call (800) 882-4666 sales@bullmoosetube.com NFPA. 1819 CLAM Road Chesterfield. MO Gerald, MO Kent, WA Casa Grande-AZ Dallas,IX Mas* OH ULLt CvE'*NY 63017 B 1.98 1.222 3.44 1844 2.78 2.330 1.66 2.809 1.00 3.361 1.00 4.968 2.019 6 1 2.860 61 3.982 37 5.299 30 7.144 19 11.290 19 ( ; _ 1DL 1L - -------- - - ADVANTAGES OF BULL MOOSE TUBED EDDY FLOW° Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet. dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD 110 MIC preventative coating. - NPS OLD. EDDY FLOW EDDY FLOWS WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER Ft Wt SIZE 1-114 1.660 1.530 1-112 1.900 1.728 2 2.375 2.203 2-112 2.815 2.705 3 3.500 3.334 4 4.500 4.310 Bull Moose Tube's° Eddy Flow* is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility, This product is FM approved, as well as UL Listed for U.S and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced deli-very costs and ease of handling. Furthermore, Eddy Flow's0 larger ID provides an opportunity for downsizing and further cost savings. Cortasoa Resistance Ratio per latest UL Direttoy Ustinq PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 www.bullmoosetube.com - Or From Canada Call: (800) 882-4666 sales@bulirnoosetube.com 1819 tlarkson Road - Chesterfietct MO Gerald, MO Kent WA Casa GiandeAZ Oaflas,TX wodn OH 63017 Ei ccjc3 c__ _ 11O Dull MooseTube's° Ultra Eddy° is ADVANTAGES OF BULL MOOSE TUBE° ULTRA EDDY° U a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule S tolerances for easy interchangeability with all approved or listed fittings. can be supplied roll grooved or plain end. With a larger II) than other products on the market today, Ultra Eddy* offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM'S requirement for dry systems. -- - NPS 010. ULTRA ULTRA EDDY WEIGHT WATER BUNDLE (IN) (IN) EDDY (ID) CRR* PER Ft FILLED Wt SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-114 1.660 1.546 1.40 1.107 1.920 61 1-112 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 31 'Pressfit is a Registeredlitademaik of vkraurk Compaq at America ' Coroaen Raae Ratio per latest UL Directory Litirj c®us LISTED <S> i; 4I4 NFP - B PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. (i 0 For Additional Information Contact (800) 325-4461 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Qvkwn Road - Chesterfield. MO (ieakf,M0 Kent WA CasaGrandAZ Da1X Mas01i 63017 [BTr--EI!OWaJIIE I E sYi B OFE NPS(IN) 1 1-114 1-112 2 2-112 3 4 clo.On) 1.315 1.660 1.900 2.375 ID. n) 1.201 1.546 1.786 2.261 ULTRA EDDY- EmpyWeitOft) 0.868 1.107 1.274 1.604 I VRUedYiqt(Ibtft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 ao4) 1.660 1.900 2.375 2.875 3.500 4.500 LD.n 1.530 1.728 2.203 2.705 3.334 4.310 Eip1yWeit OMt) 1.222 1.844 2.330 2,809 3.361 4.968 EDDY FLOW- Water-Filled Weight (1blft) 2.019 2.860 3.982 5.299 .144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 0D.(i). 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1. 1.097 1.442 1.682 2.157 2.635 .260 4.260 SCHEDULE SCHEDULE Emp1yWeightI&ft 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 Water-Filled We*A (M) 1.820 2.518 3.053 4.223 5.893 7.957 11.196 C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.315 1.660 1.900 2.375 ID. (in) 1.137 1.482 1.712 2,177 EDDYUTE° ErnptyVit(tb1ft 1.260 1.617 1.967 2.617 Water-Filled Weight (Ib/ft) 1.700 2.364 2.965 4.230 . C.R.R. 0.13 0.08 0.12 0.16 0.11 c) 1.295 1.650 1.900 2.375 LD.n 1.083 1.418 1.645 2.123 EDDYTHREAD EmptyVitOMt 1.461 2.070 2547 3.308 40° Water-filled Ai*n 1.860 2.754 3.468 4.842 C.R.R. 1.00 1.00 1.00 1.00 0D in 1.315 1.660 1.900 2.375 2.875 3.500 4.500 ffl(jn) 1.049 1.380 1.610 2.067 2.469 3.068 4,026 SCHEDULE Empty Weight (&ft) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 terFilIedWekjilOhft) 2.055 2,918 3.602 5.114 7.875 10.783 16.316 - - C.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 (> A For Additional Information Contact (800) 3254467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 salesbuIlmoosetube.com CIa,ison Road U 1819 thestet'IIeICL MO Geaki MO Kent WA Casa &andeAZ Da!1as1X vas OH - 63017 IF UNDER, III mill mu I I r—imly No 'I'll I 21 24 25 U - NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDYQ 0.868 91 11659 1,896 1.975 SCHEDULE 10 1410 91 2,695 3.079 3,208 1 EDDYLITE0 1.260 91 2,408 2,752 4867 EDDYTHREAD 400 1.461 70 2,148 2,454 2.557 SCHEDULE 40 1.680 70 2,470 2,822 2.940 ULTRA EDDY* 1.107 61 1,418 - 1.621 1,688 EDDY FL0W 1.222 61 1,565 1,789 1.864 SCHEDIJLE10 1.810 61 2.319 2,650 2,760 11(4 EDDYLffEo 1.617 61 2,071 2,367 2.466 EDDYTHREAD 400 2.070 51 2,217 2.534 2.639 SCHEDULE 40 2.270 51 2.431 2.778 2,894 ULTRA EDDY0 1.274 61 1,632 1,865 1,943 EDDY FLOW 1,844 61 2.362 2,700 2.812 SCHEDULE 10 2.090 61 2,677 3.060 3.187 -ill - EDDYLITE° 1.967 61 2.520 2,880 3,000 EDDYTHREAD 400 2.547 44 2,353 2,690 2.802 SCHEDULE 40 2.720 44 2.513 2,872 2,992 ULTRA EDDY* 1.604 37 1,246 1,424 1,484 EDDY FLOW* 2.330 37 1,810 2,069 2,155 SCHEDULE 10 2.640 37 2,051 2,344 2.442 2 EDDYLITE0 2.617 37 2.033 2,324 2,421 EDDYTHREAD 40,1 3.308 30 2,084 2.382 - 2,481 SCHEDULE 40 3.660 30 - 2.306 2,635 2,745 EDDY FLOW* 2.809 1,770 2,022 2.107 2-1(2 SCHEDULE 10 3.530 30 2.224 2.542 2.648 SCHEDULE 40 5.800 3,654 4,176 4,350 EDDY FLOW 3.361 1.341 1,533 1,596 3 SCHEDULE 10 4.340 19 1,732 1,979 2,062 -- SCHEDULE 40* 7.580 3,024 3.456 3,601 EDDY FLOW* 4.968 1.982 2,265 2.360 4 SCHEDULE 10 5.620 19 2,242 2,563 2,670 SCHEDULE 4Q* 10.800 4.309 4.925 5,130 6 SCHEDULE 10 9.289 10 1.951 2,229 2,322 8 SCHEDULE 10 16.940 7 2.490 2,846 2.965 10 'OAv&bl in Casa Gnmde,AL 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bulirnoosetube.com sales@buflmoosetube.com jB1 I'll!a 0 L1®5JE TLi!JE fEMQ-IN EIJ1[EaE SAWYFB—r -.EI 1T1S Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. U Max. Transverse and 4-way Brace Spacing t) According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Qi for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11(4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1112 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 112 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 4551 381 40 40 40 40 37 1 34 31 29 28 26 25 24 4 1 1544 12351 10121 8671 7261 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or CompressionlGrooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & p for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 7-5511 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 1 1/2 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED <9> krf4 I NFP C For Additional Information Contact (800) 325-4461 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bulimoosetube.com 1819 Ctarkson Road thesterfIetctM0 6erak1,MO Kent WA CasaGrandeAZ Da1X Ma0H UL 63017 11 Mechanical.T® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe, They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on F-IDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No, Submitted By Spec Sect .Para Location ------------------------------------Date Approved Date www.victaulic.com vcTAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 vIcTAULIC COMPANY. ALL RIGHTS RESERVED. REV H 'j6teuIicr 1102 1 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11,03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2>< 1/2 /50 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections, 9iia11l '' 3rGm 5'dlYv Q~11 '16 rri i .7r4i47 A. 121 9 m7v 14 AL -, M iki-l 1'~ _' ' '• i 2 , ½ (a) a 500 1.50 2,00 253 - 161 5.35 2,75 3.1 - 50 15 3450 38.1 51 64 41 136 70 1.5 '14 920½ 500 150 197 253 161 5.35 2,75 3.1 20 3455 38,1 50 64 - 41 136 70 1,5 - (a) 920½ 500 150 185 2.53 ' 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 (a) iu 920½ 500 1.75 205 2,75 3.00 161 535 3.00 3.5 32 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1112 (a) tIl 920N 500 1.75 203 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 920½ 3450 500 44.5 1.50 52 2,21 70 2,74 79 41 1.82 136 5.64 83 2.75 1.7 3.0 1.5 - 2½ ½ (a) §a 65 15 3450 38.1 56 70 46 143 70 1.4 46(a) §0 920½ 500 1.50 2.18 2.74 1.82 5,64 2,75 3.0 - 20 3450 381 55 70 46 143 70 1,4 920N - 500 150 ' 2.06 2.74 - 182 5.64 2.75 2.9 - 25 3450 38.1 52 70 46 143 70 14 114 t (a) P 92 0 1 500 1.75 ' 2.30 3.00 3.25 1.82 6.29 3,00 ' 3,5 3.2 32 3450 44.5 58 76 83 46 160 76 1,7 1.5 1½') (a) a 120" Soo ' 2.00 2.28 3.00 3.25 1.82 6.26 - 3.25 3.6 3.3 40 92014 3450 300 50.8 1,501 58 2.22 76 2.75 83 - 46 2.25 159 6.46 83 3.18 1.7 3.9 1.6 - 7 ,, ½ Ia) IS 2055 381 , 56 70 57 164 81 1.8 46(a) 920½ ' 300 1.50 2,19 2.75 2,25 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 164 81 1,8 - 1 (a) 920½ 300 150 2,07 2.75 - 225 ' 6,46 3.18 ' 3,8 25 , , 2065 38.1 , , 53 , 70 , 57 164 81 1.7 I 14(a) 920½ 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 , 3450 44.5 , 58 76 84 49 160 76 1.6 1.5 1½ (a) rl 920½ 500 2,00 2.28 3.00 3.31 1.92 6.29 ' 3.25 3.5 3.3 40 92½ 3450 500 , 50.8 1.50 58 2.52 76 3.05 84 - 49 2,23 160 6.15 83 2.75 1.6 ' 3.4 1,5 3 ½ (a) a 80 ' 15 3450 38.1 64 78 58 156 70 1,6 , 3/4 (a) a ' 92,,N 500 1,50 ' 2.49 3.05 2.28 6.15 2.75 3,4 20 3450 38.1 63 78 , - 58 , 156 70 1.6 - 1(a) 920½ 500 1.50 ' 2.38 - 3.06 - 2,28 6,15 2.75 3.3 - 25 ' 3450 38,1 61 , 78 , 53 156 70 1.6 1 '3 (à) tU 920½ 500 1,75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) ' 3450 44.5 65 83 , 90 58 156 76 1.8 1.8 1½ (à) tu 920½ 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4,1 3,8 40 (b) ' 350 50.8 , 71 89 , 90 58 , 156 83 1.9 1.8 , 2 (a) a 920½ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 920½ 3450 500 63.5 ' 2.50 70 3,00 89 90 3.75 58 244 172 6.72 99 3.88 2.3 2,1 3.8 3/z x 2 90 3453 63.5 76 - 95 62 17 '1 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. 6 Female threaded outlets are available to NIPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order, (b)For 76,1mm threaded outlet, specify 2½" BSPT clearly on order. Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.vlctaullc.com \l#tauIac' (/ICTAULIC IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. 612017 VICTAULIC COMPANY. ALL RIGHTS RESERVED, 11.02 2 REV ft CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-To Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 0s O 1861 i 0 (! 8 V '' 5 •a rc' 'r -A' 0'4ia.144ic-' - 4 V 3L 32a .u1" O TABLE CONTINUED FROM PAGE 2 4 ½ Ia) a 500 1.50 3.03 3,56 2,69 7,01 2.75 37 100 >1 F 920¼ 3450 38.1 77 90 - 68 178 70 1.8 t4(ai 90¼ 530 1.50 3.00 355 - 2.69 7.01 2.75 3.7 - -- 20 3450 38.1 76 90 68 178 70 18 W (a) a 500 1.50 2.88 3.56 2.69 701 2.75 3.6 - 25 9L01 3A53 38.1 73 90 - 68 178 70 1,8 GROOVED OUTLET 1¼(a)ta 920¼ 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3,6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1½()'a 500 2.00 3.28 4,00 4.00 249 7.01 3.25 4,2 3.9 V ________ 40(b) 920N 3450 50.8 83 102 102 68 178 83 2,0 1,9 4 *-Zi - 2(a) Ta . 500 2.50 3,25 4.00 4,00 2.69 7.01 3.88 5.0 4.6 t I1 3450 63.5 83 102 102 68 178 99 23 2.1 V . 2112(a)t 920 500 2,75 2.88 400 4.00 2.69 7.34 4,63 5.8 5.0 - T 65 3450 69,9 73 102 102 68 186 118 2.6 2.3 - - - - - 76 1 92 500 2.75 2.88 ' 4.00 2.69 7.54 ' 4,63 64 mm 0 3450 69.9 73 - 02 68 186 118 - 2.9 9 3bit 500 3.50 3,31 4.50 4.12 2.69 7.73 5,12 84 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET . . . 1 ¼ (a, ) -a 500 1.75 3,08 3.78 2.63 754 305 53 108.0 < 32 0N 3450 44.5 78 96 - 07 94 78 2.3 - 1 1/2 (a)a 500 2.00 3.28 ' 4.00 ' 2.63 7.64 3.25 5.0 Provides a direct branch connection at 40 920¼ 3453 503 83 102 - 57 194 83 23 - any location where a hole can be cut Tai 920¼ 500 2.50 3.25 ' 4.00 2.63 7,64 4.00 4.0 in the pipe 50 3450 63,5 83 102 ' 67 194 102 1.9 920 500 2.75 2.88 4.00 4.00 253 7.64 4.29 8.0 7,8 A pressure responsive gasket provides 3450 69.9 73 102 102 , 67 194 109 3.6 3.5 the seal 3(a) a23 500 3.50 3.31 4,50 4.50 2,63 763 4.88 6.8 6.5 80 ' 3450 88.9 84 114 114 67 194 124 3.1 3,0 Request Publication 1103 for 5 , 1½ (a) t 920 500 2.00 4.03 ' 4.75 4,75 3.15 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 '40 , 3450 50.8 102 121 121 80 246 94 , 3.4 34 2(a) t 90 500 2.50 4.00 4.75 4.75 3.16 9,70 4.38 82 8.0 Pressure rated up to 500psi/3450kPa 50 3453 63.5 102 121 121 80 , 246 111 3.7 3,5 on steel pipe; also available for use 21/2 (a) 7 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 6,h m 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 Sizes from 2 >< ½/SO x 15mm 3450 - 59,9 - 121 80 246 118 - 3.6 through 8 x 4/200 2< 100 mm 3(a) 7 920 500 3,50 3,81 5.00 4.63 3,15 9.70 5.31 8.4 8.8 80 3450 88.9 97 , 127 118 80 246 , 135 32 4.0 2 ' 500 2.50 3,75 4.50 3.17 8.00 3.88 8.0 133.0 x 50 9201\I 3450 63.5 95 114 - 81 203 99 3.6 - 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 2 3450 88.9 97 127 - 76 240 135 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another f Center of run to end of fitting. to achieve cross connections, A Female threaded outlets are available to NPT and BSPT specifications. See page 7 for Fre Protection approvals and pressure ratings, (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order, (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. Vds approved for fire protection services a 1-PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. wwwvlctaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. * 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Actsube. EV N 1102 3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 1102 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 0 . 0 (1 , Im ill ?0 r" imr 'taer 'no, riro rain 6r4r1 '! '3 4 Y z O rr_ TABLE CONTINUED FROM PAGE 3 1397x½T 920N 500 2fl0 378 4.50 - 330823 3.25 73 40 3450 50.8 96 114 84 209 83 12 2+ 20¼ 500 2.53 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 84 209 99 4.1 W 6 , ¼ (a) 500 .75 4.43 5.13 5.13 3.79 9.15 3,25 5.1 4.8 150 32 (bi 920¼ 450 445 112 130 130 96 232 83 2,3 2.2 GROOVED OUTLET 1½ (a) j'a 00 2.00 4.40 5.13 5.13 2.79 9.15 3.25 5,4 5.1 40(h) 92014 5 3450 508 12 130 130 96 232 83 2.4 2.3 2(a) ta 500 2.50 438 5.13 5,13 3.79 935 3.88 6.0 5.6 50 92uI 3450 63.5 111 130 )30 96 232 99 2.7 2.5 4 Y 2/2 . 500 2.75 4.01 5.13 3.12 3.69 0.51 4,63 8.3 7.6 65 924 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 500 2.75 4.15 5.21 3.99 10.51 463 8.4 I T 76.1 mm 92 3450 699 105 132 94 267 '18 - 3.8 - 3(at 92' 500 3.50 4.31 5.50 5,13 3.69 10.51 5,31 9.9 ' 8.4 w 80 , 3450 88.9 110 , 140 130 94 267 135 , 4.5 3.8 4(a) to 500 4.50 3.81 5.75 5.38 3.69 10.51 6,25 10.1 10.1 100 920 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET "/2 I 4(a) iOO 2.0 441 3 - 3.63 94.3 3.25 7.8 - L9.0 x 40 920 3450 50.8 112 130 92 239 83 3.5 2 (a) ' 500 2,50 4.38 5.13 3.63 9.40 3.88 8.0 Provides a direct branch connection at 50 92014 3450 63.5 111 130 - 92 239 99 36 - any location where a hole can be cut 76 ' mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe , 3450 69.9 III 140 130 92 239 118 43 , 4.3 3 500 3.50 4.31 5.50 5,13 3.63 9.40 5.31 8.1 4,0 A pressure responsive gasket provides 80 920 , 3450 88.9 110 140 130 92 239 , 35 3.7 6.4 the seal (08Or 500 4.50 445 - 5.38 3.63 9.40 612 - 10.0 rn 2 3450 114.3 113 137 92 239 155 4.5 Request Publication 11.03 for 4 500 4.50 3.81 5.75 3,63 9.40 6,25 18.0 - Mechanical-T cross assemblies 100 920 3450 114.3 96.80 46 92 239 159 8.2 TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe Center of run to end of fitting. Sizes from 2 x ½/SO x 15 mm 4 Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services 0 LPCB approved for fire protection services IMPORTANT NOTES; 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.vlctaullc.com . \/.tauIiC' VICTAuLIC IS A REGISTERED TRADEMARKOF VICTAULIC COMPANY. © 2017 VICTAIJIJC COMPANY. ALL RIGHTS RESERVED. I1,02 4 REV,,FI STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET ~ to__~ Z -17 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-i' cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15mm through 8 x 4/200 x 100mm cARBON STEEL PIPE. HOLE CUT PRODUCTS 11.02 MechanicalT Bolted Branch Outlets .fri3 G r17a? 9.1W Cft ss TABLE CONTINUED FROM PAGE 4 W rr (fi !1xr4i, 05- '2f34w 55' 'IiIl 'is 1:4 b 31ar. 155 25 530 50 388 456 379 934 27 80 340 38 99 116, 96 237 70 36 1/ n 530 75 443 SJ3 379 934 325 84 32 3450 445 13 loT 96 237 83 3,8 1½(a) ,, 30 200 4,41 - 5 3 '3 379 - 934 3,25 34 4 20 53 502 U2 laO 130 96 237 83 3,8 2.4 2 () t WON 50 250 438 513 5.13 379 934 338 85 6,0 50 11,50 635 11 130 130 96 237 99 39 27 761 mm 920 500 275 401 513 521 36 1 (151 463 86 7.6 34w 699 110 130 132 92 267 1'8 39 32 31at0 920 oo 350 43' 253 313 363 10311 531 10,2 32 80 340 889 110 140 13' 92 267 '32 46 38 4 a) 920 500 450 - 3.81 75 538 3,63 10 6.25 105 8 09 920 3450 430 ' 43 27., 97 542 146 6,19 137 625 92 481 267 1242 159 450 48 1 1.6 38 1 16 8 x 2(a( 200 50 3450 699 138 IS7 '59 22 alE 114 53 53 2'/2 'a) 920 - ..0 275 507 69 69 48 142 450 16 1,6 65 3450 699 129 o7 17 316 I 2 5.3 53 761 mm 2 90 00 o75 305 625 48 1242 456 1 6 - 3450 E99 - 22 , 316 116 53 920 5 00 _.52 531 630 650 4 1242 53 126 1 3Itu 3450 889 '35 52 165 '22 316 F5 ° 53 4920 500 45 281 675 638 48' 1o42 625 53 12,5 3450 143 122 1711 162 12 31 59 69 57 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 'f Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. 8 Female threaded outlets are available to NFL and BSPT specifications, @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed, Specify "BSPT" clearly on order, (b)For 76,1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services e LPCB approved for fire protection services 0 Approved for use in China by Tianjin Aoprovals Company, IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com '%.,$4t2uIIc' VICTAULIO IS A REGISTERED TRADEMARK OF VICTAIJLIC COMPANY 52017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV Fl 11,025 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T11 fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C and KvValues Values for flow of water at +60F/+16°C are shown in the table below. Formulas for CvjKv Values: =Q2 It ap Where: p = Q2 Where: Q=Flow(GPM)Q=Flow(m3/hr) = FA a = Pressure Drop (psi) C= Flow Coefficient v AP = Pressure Drop (Bar) = x ,j K= Flow Coefficient Exaggerated for clarity FquNaluni Length of 110 Cafbon Stiel Pipe 0.840 - 2 11 15 21.3 94 IK 1.050 - IrS 20 26.7 13.7 1 1,315 . 8 - 21 25 33.7 LB 1.660 3 SC 48 32 42,7 42.9 41.1 1½ 1.900 - - 53 53 40 98.3 ' , - 45.4 45.4 2 ' 2,375 9 10½ 5 112 104 50 60.3 96 89.1 2½ 2,875 . 20 119 150 65 73.0 102 128.5 3.000 76.1 mm 16 161 76.1 138.1 - ' 3 3.500 14 15½ 249 - 237 80 88.9 2134 203,1 4.500 20 421 401 00 114,3 360.8 343,6 Hazen-Williams coefficient of friction Is 120, Pipe with a wall thickness of 0,165in14.2mm. 1 FireLock Innovative Groove System fIGS) outlet www.vlctaulic.com ./t,auIic VICTAIJLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 3/ICTAuLIC COMPANY. ALL RIGHTS RESERVED. 11,02 6 REVS.N CARBON STEEL PIPE. HOLE CUT PRODUCTS 11.02 ViechanicalT0 Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication, Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. so I11- - rp 21/2 -6 2.875 - 6.625 At '0 40 400 400 400 290 232 362 65-150 73.0-1683 2755 2755 2755 1999 1599 2496 21/2 -4 2.875 - 4.500 All OF 300 300 300 290 232 362 65-100 73,0-114.3 2065 2065 2065 1999 1599 2496 21/2 -4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 73.0-114,3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 - 232 362 50 68.3 2065 2065 1724 1999 1599 2496 6 6.625 34 30,40 300 300 300 290 232 362 150 68.3 2065 2065 - 2065 1999 599 2496 8 8.625 21/2 10,40 400 - - - 145 - 260 219.1 2755 1000 8 8,625 34 10 300 - 250 - 145 - 200 219.1 2065 1724 1000 8 8.625 3,4 70,40 300 - 300 - 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe, 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation, VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 87100 - 200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5/125mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 2W/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with (1 safety codes. - For more information, refer to publication 24.01. www.vlctaulic.com ,- VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ictaul.c REV PI 11,027 MechanicaIT' STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Held Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victauliccom. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details, NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions, Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11,02 14BO REV N UPDATED 12/2017 -1* A10—t—Quixf vcruuc IS A REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1102 L FireLock STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK or VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G \4taulicr 10,52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock OutIetT STYLE 922 DIMENSIONS 0 46.5 27.9 9 it i wj ~ 13A 1.28 1.83 1.10 3.87 2.56 1.1 - 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1/ 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 x ½ 1 3A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 13A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 417 58.4 31.0 103.6 65.0 0.59 2 x ½ 1 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/4 1/o 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3/16 1.88 ' 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 x ½ 1/o 1.91 2.44 1.71 5.40 ' 2,56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3,4 1 3A6 1.89 2.44 1,71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 2.13 2.79 ' 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 1 1.91 2.44 1.71 5.50 ' 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 1397 65.0 0.73 /4 1 3Ao 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 1397 65.0 0.73 1 1 3A6 ' 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70,9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com ictaulid vicTAuLic IS REGISTERED TRADEMARK OF vlcTAuuc COMPANY. © 2009 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. 1052 2 REV 6 PS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 FireLock' OutIetT STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. dactauhice REV G 10.52 3 FireLock STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 /taulic vicTAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10,52 I' fi i msii1 ii iiiiI1U I iT - in 1 'I'III1)1f1 PiAi1Ii1 i iaj ui IiT1tIIl I1T,,p Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP ®L Ductile iron castings conform to ASTM A536 c us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 500 150 200 480 460 250 300 440 -- 350 420 400 400 450 380 00 --- 360 550 340 600 320 650 300 c®us FIVI ? Fig. 35E 3-90° Elbow LISTED Size in Part Number e A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 - 0.2 3/4 35E 3006 131 70 140 0,3 1 35E 3010 - 1.50 40 80 0,5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Size in Part Number A in - B in Packing Weight lb Inner I Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0,3 lx 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 J4x 1/2 35RE3012004 1.53 35 70 0.5 1.34 1-1/4x3/4 35RE3012006 1.45 - - 1.63 35 70 0,6 1-1/4 x 1 35RE3012010 1.58 - 1.67 30 60 0.7 1-1!2x1/2 35RE3014004 1.52 1,75 30 60 0.6 1-1/?x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 18 36 TO 1.88 2x 1/2 35RE3020004 1.60 1.97 18 36 1,0 - 2x3/4 35RE3020006 1,97 18 36 1.0 1.60 2 x 1 35RE3020010 1.73 2.02 16 32 1,2 2x1-1/4 , 35RE3020012 35RE3020014 1.90 2.02 2.10 2.16 12 10 24 20 1,3 1.5 2x1-1/2 2-1/2x1-1/2 35RE3024014 2.16 6 12 2.2 2,51 2-1/2x2 35RE3024020 1 2.39 2,60 6 12 2 - Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 - 3/4 , 1 35F 3004 35F 3006 35F 3010 0.88 150 300 160 80 - 0.2 - TT 0.5 0.7 to 1.6 2.7 0.98 80 1.13 40 1-1/2 - 2 2-1/2 35F 3012 35F3014 35F 3020 35F3024 - 1.29 25 - 50 40 - 1.44 20 10 4 1.69 1,95 20 8 Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master - 1/2 3/4 1 35T3004 3513006 1.13 80 30 - 25 160 60 50 - 20 20 12 8 0.3 0.5 - - 0.7 1.1 1,5- 2.4 4,3 1.31 3513010 - 35T3012 35T3014 1,50 1.75 1-1/4 1-1/2 2 2-1/2 10 10 6 1.94 3513020 3513024 2.25 2.70 4 111. SMITH-COOPER INTERNJ\TIONAL 0 TOLL FREE I-900-766-0076 • FAX (323) 890-4456 0 i8TAvsmkhvooper vom Size in Part Number A in B in C in - Packing I Weight lb Inner IMasterl 314x 1/2 35R13006004 1,20 1,20 122 60 120 0,4 1x1/2 35RT3010004 1.26 126 1.36 30 60 0.6 lxl/2x1 35RT3010004010 150 1.36 1.50 30 60 0.6 - 1 x3/4 - 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 1.50 1.45 1.50 2 50 0,7 1-1/4x 1/2 - 35R13012004 1.34 1.34 1.53 ' 1.75 . 20 40 0.8 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x314x1-1/4 35R13012006012 1,75 1.62 1.75 20 40 10 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 126 1.53 25 50 07 1.34 1-1/4x1 x 3/4 35R13012010006 1.45 1.38 1.63 20 40 0,8 1-1/4x lxi 35RT3012010010 1.50 1.69 20 40 0.9 1.58 1-1/4 x1x1-1/4 35R13012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1,66 16 32 1.0 1 Al , 1-1/2x1/2x1-1/4 35R13014004012 1.81 1.56 1.88 24 12 ' 48 1.1 1-1/2x1/2x1-112 35RT3014004014 1.94 1.66 1.94 24 1.2 - 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 20 ' 32 1.1 1-1/2x3/4x1-1/4 35R13014006012 1.94 1.66 1.88 40 1.1 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1,94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1,80 12 24 1.2 1-1/2x1x1/2 - 358T3014010004 1.44 1.25 1.69 20 40 0.8' 1-1/2x1x3/4 35RT3014010006 1.50 1.44 , 1.75 16 32 0.9 1-1/2xlxl 1-1/2xlx1-1/4 ' 35fRT3014010010 1.65 1.50 1.80 16 32 1.0 1.82 1.88 12 24 , 24 1.2 35RT3014010012 1.67 1,94 1-1/2x1x1-1/2 35AT3014010014 1,80 1,94 12 24 1.3 1-1/2x 1-1/4 35R13014012 1.82 1.88 _12 1.4, - 1.82 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.45 1.66 1.75 16 16 32 32 , 0.9 1.0 1-1/2x1-114x3/4 35RT3014012006 1.52 1-1/2x1-1/4x1 35AT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35RT3020004 1.49 1.88 10 20 1.5 1.49 2x3/4 35R13020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1,73 2.02 8 16 1.7 1,73 2x1x2 35813020010020 2.25 2.02 2.25 8 16 1.9 , 2x1-1/4 1.90 2.10 8 16 , 16 1.9 35813020012 1.90 2x1-1/4x2 358T3020012020 2.25 2,10 2,25 8 16 - 2.0 2x1-1/2 2.16 8 2.1 35RT3020014 2.02 2.02 2x1-1/2x1/2 35813020014004 1.49 1.41 1,52 1.88 1,97 2.02 10 10 8 20 20 16 - 1.3 1.4 1.5 2x1-1/2x3/4 358T3020014006 1.60 2x1-1/2x1 35813020014010 1.73 1.65 2x1-1/2x1-1/4 1.82 2.10 8 16 1.7 35R13020014012 1.90 2x1-1/2x 1-1/2 35RT3020014014 2.02 1.94 2.16 1 8 16 1.8 I C®uS APPROM Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x1 1 x 1-1/4 lx1-1/2 1-1/4x1x1-1/2 1-1/4x1-1/2 1-1/4x2 1-112 x 1-114 x 2 1-112x2 35613006010 35B13010012 35613010014 35813012010014 1.45 1.67 1.80 1.45 1.67 1.80 ' 1.80 1.88 2.10 210 2.16 1.37 1.58 1.65 1.82 1.82 190 202 2.02 30 20 15 - 15 15 10 10 8 60 40 30 30 30 20 20 16 0.6 0.9 1.0 1.2 1.3 1.6 18 18 - 1.88 356T3012014 1.88 35BT3012G 358T3014012020 35B13014020 7f10 216 2.16 SMITH-COOPER tNTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smirhcooprcorn 112 Fig. 3503 - Straight Coupling with Ribs C@US < Ae>PPROVED LISTED Size in Part Number _______ in Packing Weight lb Inner Master 1/2 - 35CP3004 1,38 200 400 0.1 3/4 35CP3006 163 100 200 0.2 1 35CP3010 - 1.75 60 -- 120 0,4 1-1/4 35CP3012 2.00 35 70 0.5 - 1/2 35CP3014 219 25 50 0.7 2 35CP3020 2.62 15 30 1.2 21/2 35CP3024 300 9 18 22 Sue in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1 x3/4 1-1/4 x 1 1-1/2x1 1-1/2 x 1-1/4 2 x 1 2x 1-1/4 35H83010004 35H83010006 35HB3012010 35HB3014010 35HB3014012 35H83020010 35HB3020012 1.06 1,06 119 180 180 90 360 - 360 180 150 150 80 80 80 0.2 -Fl- 0.2 0.4 0.3 1.25 125 1.38 75 75 40 0.6 0.6 0.6 - 1.38 40 2x1-1/2 35H83020014 - 1,38 40 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 353P3004 35S__ 006 35SP3010 0.94 1.12 600 350 200 1200 700 400 0.07 0.1 0.1 1 1.25 1-1/4 1-1/2 35SP3012 35SP3014 1 35SP3020 1.37 1.44 100 80 200 0.3 0,4 160 90 2 1,50 45 0.6 LL!I ,ou'r,00400 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner I Master 1 x 1/2 35RC3010004 1.69 80 160 03 - 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 , 35RC3012006 2.06 40 - 80 -- 0.6 x (no 2 1 t hex) 35RC3020010 20 40 2.81 1.0 Fig. 35HB3 - Hex Bushing uIi Fig. 35U 3- Union with Brass Seat Size in Part Number ___ - A in Picking Weight lb Ihfler Master ____ 35U3010 35U3012 35U 3014 35(T3-6 25 2.19 20 40 1.0 1-1/4 1-1/2 2 2.50 15 10 6 30 - 20 12 1.2 - 1.7 2.62 3.12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890446 0 wwwsmihcoopr.om R al U A01 KIN 6k- lil <e> APPROVED Fig. 35X.7 - Cross LISTED [SIZO in Part N umber U A in Packing - Weight lb Inner Master 1 35X3010 150 20 40 0.9 1-1/4 35X 3012 175 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.6 2 35X 3020 2.25 6 12 2.8 Fig. 35RX3 - Reducing Cross rSize in Part Number A in B in Packing Weight lb Inner I Master 1-1/4x1 35RX3012010 1.67 1,58 15 30 1.2 1-1!2x1 358X3014010 1.80 165 12 24 14 2x1 35RX3020010 2.02 173 8 16 20 Fig. 35C 3- Cap Size in Part Number- a in - A Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 3503006 200 400 0.1 0.97 1 3503010 1.16 110 220 0.2 1-1/4 3503012 70 140 0-.4- 1.28 1-112 350 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp Size in Numb a e - in Packing - Weight lb Inner Master 3/8 35803003 0.75 100 200 0.3 1/2 358C3004 0.75 80 160 0.5 SMITH-COOPER 1TERNAT1ONAL® 9 TOLL FREE 1-800766.0076 • FAX (323) 8904456 0 wwwsmirhvooper,com 114 LNSTALT1ON STEPS .iNTO WOOD & STEE!FINST-A-LL-ATI ON STEPS -1NTO WOOD & STEEL I. Insert the appropriate nut driver into a 3/8" or 112* portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position, Push the face of the nut driver tight to the member, Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 4, The SAMMYS is now ready to receive 1/4' 3/8", 1/2" or metric all thread rod, boll stock. (The 1/2" requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for maximumpullout in purlin steel. jjM,'J7EjM-7 Insert the appropriate nut driver into a 3/8" or 1/2"portable drill Insert the SAMMYS into the #14S W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation, When the nut driver spins freely on the SAMMYS, stop the drill and remove, The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for maximum pullout in purlin steel. [INSTALLATION STEPS INTO CONCRETE:1 Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre -drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver, Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock, (#I4SW red nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode doing so will destroy the pullout factor of the screw. [INSTALLATION STEPS - J Ii1i1L INTO CONCRETE: Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammerl rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 318" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation, Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener, I f IWM fillIIUtiMIullilkilY. ..ki1 PECK NVT ORSVER $Y5TUL The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver cornea into contact with the material you are installing into continue drilling until nut driver spins free Installation is then complete Warranty requires the use of the appropriate nut driver for installations 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1.1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1.1/2" 8008957 CST 20 318" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST2O.SS 3/8" Vertical 2-1/2" 850 1.1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-112" 4" 1475 1-1/2" 8009925 0S125-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-112"-4' 1500 1-1/2' 8021957 SWG 20 3/8" Horizontal 2-1/2"- 3""" 1050 1-1/2" 8073925 SWO 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-esl/CST 20 /8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17° Angle off Vertinal 1050 1-1/2" 4" 1475 1-1/2" 8038957 OSTR 1 3/8" Vertical 1500 .035" 4" 1475 .105" 8037957 QSTR 1-1/2 3/8" Vertical 4" 1600 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK5O 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWOR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 060" 8137957 SH-D$TR 1 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK5Q 3/8" Vertical 2-112" 850 70" Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 4' 1475 05 8153922 XP 35 3/8" Vertical 4" 1500 .060" 8294922 SXP 20 3/8" Vertical or up to 45" 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89" 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP3S 3/8" Horizontal 3-1/2" 1250 .060" SAW"YS FOR CONCRETE- PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC 5 35 PCF (lbs/ft3) 8150922 XP 20 3/8" Vertical 185 .027' 250 035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027" 45" 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060' 90" 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMI, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC A 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMI & 6 trade axe RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8W Horizontal 500 .060" Max 4 trade size EMT & 6 trade oze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 114" or 3/8' Onto Vertical Rod UL L/sted 4816. Cable Hanger, Cat, No. C-Z2000 Plenum Rated, 11TTII Steel Tt*1i1wIou Complies w/ NEC Standards Gauge No, 22 go, 2000, lose, 1698, 14 go, 1200, 1/8" 3/161' 1/4" Nominal Decimal Equivalent .030" .036' .048" .060' .075" .105" .125" .188" .250' 8W0 25-380 Man/mum pipe size in campsite wood mint allowed by UL /s 3-1/2" UI. compliance with NEC Standards, SWG 25-380 Maximum pipe size in wood limber or/net allowed by UL is 4 SWG 20 Maximum pipe see in composite wood joist attoweit by UI. is 2-11z' UI. and FM tents were performed in compliance with NFPA 13 Standards. 'SWG 20 Maximum pete size in wood Umber or bat allowed be Ut. is3 Fastening requirement: 5 times weight of water-flied schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-puin applications in May 1997 using (.037) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Prese was completed using (.030") or 22 gauge steel metal deck. Sammys Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for Installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring, Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported, Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/B" smaller than root diameter of fastener. Consult the table below: GST 20 .182" 118" GST 25-380 .280" 7/32" SWG 20 .182" 118" SWG 25-380 .280" 7/32" To increase efficiency of the Installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPAINEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at w,itwbuildex.com AUG tSflO AS cCaST NC CAASA a,otnoAs.Acn.oua.an SC, Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information I Listinas/AoDrovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor i T l IndeDendent code evaluation IBC®/ IRC® 2015 IBC®/ IRC® 2012 IBC®/ IRC® 2009 lBC®/ IRC® 2006 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hliti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dbt in. 1/4 Nominal embedment h nom in. 1-5/8 2-1/2 Effective embedment h41 in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T Inst ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 T155 is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size _d fanch - , h e hnom h dbt-_. Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2,3,4,5 Nominal Nominal Tension - pN Shear - On anchor embed. = 2,500 psi f', = 3,000 psi f' = 4,000 psi f' = 6,000 psi f' = 2,500 psi f' = 3,000 psi f, = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' .1,3,4,5 Nominal Nominal Tension - 4N Shear - On anchor embed. f' = 2,500 psi f' = 3,000 psi f' = 4,000 psi IC 6,000 psi f = 2,500 psi f = 3,000 psi I',, = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A5 as follows: for sand-lightweight, A5 = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - aN = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNO = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWlK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile3 Shear' Seismic shear' diameter thread diameter 4N <Wsa 4V in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension 4PN. = 4'A 5f,,,5 as noted in ACI 318-14 Chapter 17, 4 Shear determined by static tests with 4'V,5 < 0.64'A,05 f,,, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with cV Si 5 4' 0.60 A 5 f as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800.363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete1'2 Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 uncracked concrete f. I RN lay 1RV fRy 1HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h nom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a j 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 8 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 1 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 - 4-1/2 (114) 0.89 0.81 cc 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 10 (254) 0.89 CL 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete',' Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' .L toward edge from edge factor in shear' cracked concrete f I RN 11V 1RV fRy 1HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4.1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 ca 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 a 5-1/2 (140) 0.98 0.83 0.72 0.93 0) 5) 6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 a 10 (254) 0.90 11 (279) 0.94 12 (305) 0.98 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, fA' assumes an influence of a nearby edge. If no edge exists, then fAv = IAN 4 Concrete thickness reduction factor in shear, f, assumes an influence of a nearby edge. If no edge exists, then 'A/ 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Shear - Tension - cpN Shear - On anchor thread embed. f',= 3,000 psi f.= 4,000 psi f'0 = 3,000 psi f= 4,000 psi f'0= 3,000 psi f'= 4,000 psi f= 3,000 psi 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck""',,, 6,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - 4N Shear - pV Tension - (pN Shear - On f',=3,000 psi = 4,000 psi = 3,000 psi = 4,000 psif = 3,000 psif', 4,000 psi P = 3,000 psi = 4,000 psi anchor thread embed. diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) 2-1/2 605 700 610 610 635 735 610 610 UNC (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 / 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,Oi = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Min 3/4' 7, Min, 3,000 p*lsand-lightwelght or normal-weight concrete,~'_ Upper flute (Valley) v Minimum (typical) 20 gouge steel deck Lower Flute edge typical flute (ridge) Mm. 12" (typical) Min, 1.1/4' - 1 Anchors may be placed In the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-Inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. N 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSAA23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with GSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile3 Shear4 Shear4 diameter diameter N V V in. (UNC) Sar lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N = cp f,,, R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V, < A 0 q 0.6 f,,, R as noted in GSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with <A,0,11 q 0.6 f, R as noted in GSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I an español 1.800.879.5000 1 Hilti (Canada) Corp. 1-800-383-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. do in. 1/4 (mm) (6.4) Effective embedment2 hat in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 h in. 1-5/8 2-1/2 nom (mm) (41) (64) Minimum concrete thickness h. in. 3-1/4 4-1/8 min (mm) (83) (105) Critical edge distance C, in. in. 2.00 2.78 (51) (71) Minimum spacing at critical edge distance Smincac in. 1.5 (mm) (38) Minimum edge distance C.In in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. (251) I 2-7/8 (mm) I (73) Minimum specified ultimate strength uta psi 125,000 (N/mm2) (862) Effective tensile stress area A so, in 0.045 (mm) (29.0) Steel embed. material resistance factor for reinforcement k - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 lb 3,370 Factored steel resistance in tension N, D.6.1.2 (kN) (15.0) Factored steel resistance in shear Vsar lb 750 D.7.1 .2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic Vsar (kN) (1.5) Factored steel resistance in shear Vsar lb 725 D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete knuner - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k, 11 - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc .4 tVcN - 1.0 D.6.2.6 Anchor category - - 3 1 1 D.5.3 (C) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete Npr,ncr lb 665 1,645 D.6.3.2 (kN) (3.0) (73) Factored pullout resistance in 20 MPa cracked concrete6 Nprc, lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete Npr lb 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. For all design cases, 4u6 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,) or uncracked concrete must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, q) = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete' 2,3,4,5 Nominal ___________ Tension - N, Shear - Vr I ', = 20 MPa I = 25 MPa I Ic = 30 MPa f = 40 MPa f = 20 MPa I = 25 MPa I , = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900ps1) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1/4 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concretel4345 Nominal ___________ Tension - N Shear - V f'c = 20 MPa f = 25 MPa f' = 30 MPa I = 40 MPa f' = 20 MPa f'c = 25 MPa f = 30 MPa I = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1/4 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, Aa = 0.68; for all-lightweight, Xa = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. C F33.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hitti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWlK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,45,1,7 N Installation in lower flute Installation in upper flute Nominal Tension - Nr Shear - Vr Tension - Nr Shear - V Nominal internal Nominal anchor thread embed. I = 20 MPa f'c = 30 MPa I',, = 20 MPa I = 30 MPa f = 20 MPa f = 30 MPa I', = 20 MPa I , = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,1,6,7,8 14 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N Shear - Vr Tension - N Shear - V, anchor thread embed. f = 20 MPa I = 30 MPa f, = 20 MPa IC = 30 MPa I 0 = 20 MPa f = 30 MPa f = 20 MPa f' = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h 0,,, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by aKWIS = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 ) .,1 ecetcn./ ).J KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete DaneIs1'2 Hanger rod size Mm. effective embedment h in. Allowable load' Ultimate load Tension lb Shear lb 4.1 Tension lb Shear lb 4,5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in hollow core concrete 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 1 3/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* WtJ100 3/8 13/16 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 1114 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13M 1¼ 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4' and 11/411 Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4! (Fig. 66). Features - All iteel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange whore clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8 rod will support 1/2 thru 4" pipe, 1/2 rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California OSHPD Approved c®us U3Th0 Seismic Restraints System OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951137.5599 • FAX: 991 .131.0330 CUSTOMER SERVICE • 870.786.5286 www.folco.com Fig. 25 - Surge Restrainer C@113 LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used In conjunction with TOLCOO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is Intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4,1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 82878' 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPO Approved c YL as um Seismic Restraints System Size Range - Secures 3/8' thru 7/8' hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating t9 OSHPD proigg% pleage refer to the TOLCO Seismic Restraint Systems Guidelines Finish .- Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs, Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY . 1315 SAMPSON AVE. CORONA, CA 92879• PH: 951737.599 • FAX: 9511370330 CUSTOMER SERVICE • 800.7865266 wwwwlco.com Fig. 200 Fig. 200S Ii peigieis Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) OVOLIM Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig, 0317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut c@ us USTEO Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes, Knurled swivel nut design permits hanger adjustment after installation. Features: (1/21 (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily 44 \ \ installed around pipe. For hanger with non-captured nut order Fig. 200$. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in /.- hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and 21 to 202 Factory Mutual Engineering Approved (FM) 0/4' (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pro-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size / Designed to meet or exceed requirements of . I FM DS 2-0. \ J - Fig. 200C Fig. 200F ii a . m 6i1ii ut U. te$ 200_1i2 1 12" (15) /8"-16 31/8" (794) 2/8" (66.7) 11 1 (5.0) 200-I4 3/4" (20) I8"-16 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (2 5) /8"-16 3/s" (85.7) 2/8" (66.7) 12 (5.5 200_1114 11/4 (32) 1 3/8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200_11/2 11/2" (40) 1 3/8"-16 37/8" (98.4) 2f" (73.0) 14 (6.4) 200-2 (50) /811-16 41/2" (114.3) (76.3) 15 (6.9) 200-21/2 21/2' (65) 3/8"-16 5/8' (1429) 41/8" (1047) 27 (123) 200-3 3" (75) /8"-16 57/8" (149,1) 4" (101.6) 29 (13.3) 20031/2 31/2" (90) 3/o"-16 7/8" (1 873) 51/4' (1333) 34 (156) 200-4 4" (100) /8"-16 7 /8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"_13 91/8" (231.8) 6114" (158.7) 66 (30.2) 200-6 6" (150) 1/2 c13 101/8" (257.2) 6/4" (171,4) 73 (33.4) 200-8 8" (200) 1/2"13 131/8' 1 (333.4) 1 8/4' (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown In parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200'21/z to 200-8 -. N __&ip:eIngrLs1u Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range; Fig. 200 - /2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily Installed around pipe. 21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed, Approvals; Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) Fig, 200-1 to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. / f' Maximum Temperature; 650°F (343°C) Finish: Pre-Galvanized, Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. GIi la (Isuib 0 ta uas 200M8-1/2 1/2" (15) M8 31/8" (79.4) 2/" (66.7) ii (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2/" (66.7) 11 (510) 200M8-3/4 3/4° (20) M8 31/8" (79.4) 21/2" (63.5) ii (5.0) 200M10-3/4 3/4" (20) M10 31/8' (79.4) 21/2" (63.5) 11 (5,0) 200M8-1 1" (25) M8 3/e" (85.7) 2518" (66.7) 12 (5.5) 200Mb-1 1" (25) M10 33/8" (85.7) 2I8' (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2Ig" (73.0) 13 (5.9) 200M10-11/4 F/4" (32) M10 33/4" (94.0) 218" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 37/8' (98.4) 2f8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) MW 3I8" (98.4) 2I8" (73.0) 14 (6.4) 200M8-2 2° (50) M8 41/2" (114.3) 3" (76.3) 15 (6.9) 200M10-2 2° (50) MiD 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) MiD 55/8' (142.9) 41/8" (104,7) 27 (12.3) 200M-3 3" (75) MiD 57/8" (149,1) 4" (101$) 29 (13.3) 200M-31/2 31/2' (90) MiD 7/" (187.3) 51/4' (1333) 34 (15$) 200M4 (100) MiD 7/8" (187.3) (127,0) 35 (16.0) 200M-5 5' (125) M12 91/8" (231.8) 61/4'! (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8' (257.2) 6/4" (171.4) 73 (33.4) 200M-8 1 81, (200) 1 M12 131/8" (333.4) 814" (222.2) 136 (62.3) At dimensions In charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. nru COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pro-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"..16 or 1/2°..13 adjusting threaded ring nut, Approvals: Underwriters Laboratories listed in the USA (UL) and Canada" (cUL). Conforms to Federal Specification WW-H-171E & A-A-i 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pro-Galvanized Order By; Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Gi1W 1i (W1ü (IÜ1Ü1i (tiiUiJJ 11L1IAJ LL% 200H-2-3/8 2' (50) /8'-16 4I16" (1159) 3/32" (813) 48 (21.8) 200H-2-1/2 2" (50) 1/2"_13 423/32" (119.8) 3/8' (85.7) 45 (20.4) 200H-2112-318 21/2' (65) /8"-16 5I16' (134,9) 323/32' (94.4) 59 (26.7) 200H-21/2-1/2 21/2' (65) 1/21 13 515/32" (138,9) 37/8" (98,3) 56 (25.4) 200H-3-3/8 3" (75) /a"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 112'_13 5/e' (148,1) 331/32' (100,8) 60 (27.2) 200H-4-3/8 4' (100) /811-16 6/8" (174.6) 4I16" (112,7) 76 (34.5) 200H-4-112 4" (100) 1/2'_13 71/32' 1 (178$) 419/32" (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 1, For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are In inches. Dimensions shown In parentheses are in millimeters unless otherwise specified. COOPER B-Line Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. FJGsILIFJ rmli Iwan L1 F P P I Description Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G F 0' 0o SK *YITIM COMP*t *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX+ 1800 344-3775 I -- © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc. 4 FGG/BM/CZ, Blaze-Master , FlowGuard Gold"and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE l&E11E[S 7635 RONSON ROAD o SAN DIEGO, CA 92111 o TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: sales@sandiegoseat.com • VISIT US AT: wwwsandiegoseaLcom PTFE Thread Sealant Tapes Made In the USA Our thread sealant tape breaks clean without shredding r warping, identifying it as a product that can be trusted o perform reliably when the job is completed and the ressure is on. -' Standard Grade standard grade PTFE Thread Sealant Tape is for those L Our applications that do not require the sealing properties of a premium grade thread sealant. This is intended to be used for general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, clean, economical sealing of male pipe threads of all sizes and reduces the risk of system contamination common with liquid and paste sealants. ugh-Density Thread Sealant Tape It is effective and efficient so you can use less tape. Tears cleanly.. .seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. 611 Rea.Kv Yellow Gas Un F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. IrfXMIJ FnIll *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. L i 3198 LIONSHEAD AVE I CARLSBAD, CA 92010 I TEL +1 760 599-1168 I +1800344-1822 1_I FAX+ 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com mu © 2012 Fire Protection Products, Inc. FPPI®, LubeFtO are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMaster®, FlowGuard Go/d and Corzan5 are registered trademarks of Noveon IP Holdings Corp. klA NIADE IN U.S.A. CTh r ~~e a diffi 11 - 0. 1 TgL , IN1T$jF Description ThreadFit CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary 1 ThreaFiF lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over - other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features Installation Specifications Heavy Duty Cutting Oil ThreadFit® can be used in Excellent Tool Life automatic and hand held Appearance: Clear amber liquid. Chlorine Free applicators. Fill oil reservoir Packaging: All types of ferrous metal or pipe according to equipment 1 gl, (6/case) Improved Surface Finish manufacturers specifications. 5 gl. Pail Low Odor Mixing of different types 55-gi drum 275-gi tote Low Smoke of threading oils is not recommended. DO NOT ALTER CAUTION: Skin contact: J1] THE CONSISTENCY OF THIS wash thoroughly with soap and water. Eye contact: flush PRODUCT. Use as is directly eyes with water for at least SYSTEM MPAB • from the container. Change 15 minutes and seek medical *FBCTI System Spears Compatible oil regularly for optimum attention, Ingestion: consult Compatible indicates indicates that performance. Contains petroleum a physician immediately, Inhalation: move affected this product has been ThreadFitO CLEAR oil. Avoid breathing mists or person(s) to fresh air and seek tested by Lubrizol has been tested Advanced Materials by Spearstm vapors. Avoid eye contact and medical attention. See MSDS and is monitored on Manufacturing to prolonged or repeated contact for first aid instructions. an on going basis be compatible with with skin. Wear safety glasses Spill or Leak: Soak up with to assure chemical Flameguar& pipe and or goggles. Use good personal an oil absorbent compound, compatibility with fittings. hygeine. Dispose of used oil in Follow all state, local, Federal FlowGuard Gold , regulations for disposal. BIazeMaster, and accordance with all local, State Don't pollute. Conserve our Corzane pipe and and Federal ordinances and resources-Please recycle this fittings. regulations. Consult Material container. Safety Data Sheets for additional See Material Safety Data safety and handling Information. Sheet for additional safety and DO NOT MIX WITH OTHER disposal information at I - 3198 LIONSFIEAD AVE THREAD CUTTING OILS OR www.fppi.com CARLSBAD, CA 92010 ' TEL - 1 760 5991168 J CONTAMINANTS. This product Is registered + 1 800 344-1822 with CHEMTREC, a 24-hour FAX +1 800 344-3775 emergency hot/me. They may L_ ...-. ....k...J .s .t fififi AfiA fififin I VIM rc i.) K.(j n I OVV 'Iq-.(jV. I © 2013 Fire Protection Products, Inc. FPPI, ThreaFit are registered trademarks of Fire Protect/an Products, Inc. UAUtN U4.A. ES-LF3001 A Job Name Contractor Job Location Approval Engineer Contractors P.O. No. Approval Representative Series I IiIiLFi1 Dielectric I. Sizes ½" - 2" Series LF3001A dielectric unions feature a female iron pipe thread to solder connection. These unions are designed to be installed between pipe made from dissimilar metals to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current, The LF3001A features Lead Free* construction to comply with Lead Free* installation requirements. Features Female iron pipe thread to solder connection Designed and manufactured to the highest quality standards Factory certified to withstand a minimum of 600 volts on a dry line with no flashover 'Rated to 180°F (82°C) at 250psi (17.2 bar) with standard gasket A and 300 F (149 C) at 50psi (3.4 bar) with optional gasket B Specifications A dielectric union shall be installed where indicated on the plans. The union shall feature a female iron pipe thread to sol- der connection. The dielectric union shall be constructed using Lead Free* materials, Lead Free* dielectric unions shall comply with state codes and standards, where applicable, requiring reduced lead content. The dielectric union shall be a Watts Series LF3001 A. Materials - Dimensions - Weights Standards Tested and Certified by NSF International Pressure - Temperature Maximum Pressure: 250psi (17.2 bar) with standard gasket A; 50p51 (3.4 bar) with optional gasket B Maximum Temperature: 180°F (82°C) with standard gasket A; 300 F (149 C) with optional gasket B The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thor- oughly read all installation instructions and product safety infor- mation before beginning the installation of this product. iiP4 in, TAIl. PIECE ADAPTER t Thiia:mii. NUT t INSULATOR ______________ GASKEr' - A in. mm B in. mm IfttI oz. pm. ½ Lead Free Brass Steel Steel Polysuffone Buna N 1½ 32 17/c 48 6 170 3/~ Lead Free Brass Steel Steel Polysuone Buna-N 1% 41 2½ 54 6.7 190 1 Lead Free Brass Steel steel Polysulfone Buna-N 21A 48 21/2 64 9.3 264 1¼ Lead Free Brass Steel Steel Polysuffone Buna-N V/4 57 3 76 14.1 400 1½ Lead Free Brass Steel Malleable Iron Polysutione Buna-N 2% 70 3 76 21.8 618 2 Lead Free Brass Steel I Malleable Iron Polysulfone Buna-N 31/2 89 3 76 42.6 1208 t Steel and malleable Iron components are zinc plated Optional Gasket B (GB)' EPDM Gasket for use In steam or hot water applications up to 300F (149°G) at 50 psi (3.4 bar).. *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design construction specifications or materials without prior notice and without Incurring any obligation to make such changes and modifications on Watts products previously or subsequently nold, USA: T; (978) 68946066 • F: (978) 975-8350 • Wntts.com Canada; T: (888) 208-8927 • F: (888) 479-2887 • Watts.ca Latin AmerIca: T; (62) 55-4122-0138 • Watts,m ES-LF3001A 2027 © 2020 Watts I' HAILIANG is one of the world's premiere manufacturers of copper, copper alloy and brass products including rod, fittings and tubular product. In the twenty years since its establishment Hailiang has led the industry with product development, technological advancement, market expansion and branding initiatives. N Our US based division, Hailiang I America Corporation provides national support for sales, customer service, manufacturing and regional \ distribution locations. For more information on Hailiang product please contact Hailiang America Corporation at 877-515-4522. HAILIANG AMERICA C0IPOUT[CI 16E Margaret Street • Reading, PA 19605 877.515.4522 ° fax 877.585.4522 sales@haillangusa .com Website: www.hailiangusa.corn 119 1/8"-4" 1O 1/8" - 3" JIk 1/4" -2" 1/4" -2" aaADnftow HL15-1O1 fr mEb ngEpow HL15-114 \ 1' HL15-105 1 HL15-115 Q4kJ 1/8" - 2" LU 1/8" - 6" HL15-140 HL15-154 XL14k 1/8"-8" 1/8"-o" wh hlin9 it Roll toPiX (I!X1 @flli Th HL15-165 11J 1/8" - 8" M26M 1/811-5" HL15-170 I I HL15-172 I 1/8" -8" 1/8" -3" HL15-235 HL15-242 - - •:- X7 HL15-254 r -. HLi5-272( 1I1)zs 1/4". 4" ILt 7 1/8". 3" agy I HL15-290 L.. tingReducer -c HL15-295 HL15-460 1i1t 1/8" - 6" XFk 1/4" -6" 11Z® 1/8"- 4" QL1c4:k 1/8". 8" HL15-460 C~ LL WON, H Li 5-65 7 ~ r~,~rt ii- :111.14*] HL15-947 1/4"- 8" UU&3 1/2"- 2" 1/2". 3fl XJLJ1 1/8" - 2" II:, IjLIy4II1tI it MWOMIIIIIII I` Brass PEX Fittings Green PEX Fittings No Lead, Low Zinc Plastic PEX Fittings Copper Tube Refrigeration Coils Plumbing Tube oACR Tube Line Sets jiirI s ISO Certified ASTM oA5ME °NSF61 1/8" - 8" Nominal Sizes Available Strategic Stocking Locations Nationwide cew NC Hailiang America Corp. is not responsible for typographica 011011A.0111,5M or printing errors that maybe contained in this sheet