Loading...
HomeMy WebLinkAbout3097 MADISON ST; ; FPR2021-0032; PermitPERMIT REPORT (City of Carlsbad Print Date: 03/16/2022 Job Address: 3097 MADISON ST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: 2033051003 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Permit No: FPR2021-0032 Status: Closed - Finaled Applied: 03/25/2021 Issued: 04/26/2021 Finaled Close Out: 03/10/2022 Inspector: Final Inspection: Project Title: Description: SIX ON MADISON - INSTALL NEW FIRE ALARM SYSTEM (ANALOG ADDRESSABLE, 78 DEVICES) Applicant: FPContractor: ADDAX ELECTRIC INC ADDAX ELECTRIC INC JASON GANDY P0 BOX 21436 1540 PIONEER WAY, # 100 EL CAJON, CA 92021-0000 EL CAJON, CA 92020-1638-SAN DIEGO (619) 749-8360 (619) 749-8360 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov _ADDAX E I E C I R I C I NI C. FIRE & INTEGRATION Submittal Package for: Six on Madison Condominiums 3097 Madison Street Carlsbad, CA 92008 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Remote Annunciator Power Supply Cellular Communicator Document Cabinet Smoke Detector Heat Detector Detector Base Manual Pull Station Single and Dual Input Module Relay Module Relay Low Frequency Horn Strobe and Horn/Strobe Ceiling Mount Horn/Strobe Wall Mount Weatherproof Horn/Strobe P.O. Box 21436 / El Cajon, CA. 92021 (o) 619-749-8360/(f) 619-749-8390 CSLB No: 295999 / SBE 1745359 /ALARM LIC: AC07310 I FDNY COA 6229 I 7165-1657: 0244 Features Auto-programming speeds installation time Supports V-Series intelligent modules and detectors Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Supports GSA-AEL releasing module for fire suppression Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour Alarm ON command manually activates alarm condition . y Kidde t> Small Building Fire Alarm Solutions [I 0 Technology that saves lives Intelligent Fire Alarm Systems VS1, VS4 Overview Kidde brand intelligent life safety systems offer the power of high- end intelligent processing in configurations that deliver uncompli- cated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily-configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The VS1 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The VS4 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. VS4 panels include four NACs that may be wired for either Class A or Class B operation. The RZI16-2 module adds even more capacity to VS installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them ideal retrofit solu- tions that can accommodate new intelligent detectors, as well as existing conventional devices. VS Series supports a wide range of high-end features, including: Intelligent modules, detectors, and bases GSA-REL Releasing Modules A-Series remote annunciators Integrated Carbon Monoxide gas sensing with V-PCOS de- tectors including distinct audible signaling Page lof8 DATA SHEET K850050135 Not to o. usd for 1 r s tilf -tit'r prposr Issue 1.4 Application Kidde VS Series life safety systems are powerful intelligent solutions for small to mid-sized buildings. Advanced intelligent technology delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Meanwhile, innovative pro- gramming allows the designer to customize the system to pre- cisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Address- able Technology boosts the reliability of Kidde fire alarm systems. When combined with VS Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All Kidde systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the VS Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. VS control panels also supports graphic annunciation with optional graphic annunciator interface modules. Each interface provides common control and 32 LEDs. Signals with a difference VS Series NACs are configurable to fully support the advanced signaling technology of Kidde Genesis and Enhanced Integrity no- tification appliances. These devices offer precision synchronization Programming and remote diagnostics Kidde VS Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, VS Series systems interface to a PC running com- patible VS-CU software. This option offers full system configura- tion in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of VS Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to down- load to the panel from the VS-CU, or upload and view system reports using the VS-CU. Available system reports include: Correlation groups, Device de- tails, Device maintenance, History, Internal status, System configu- ration, System status, Walk test, Dialer, and CO runtime. Page 2 of 8 of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits Kidde VS Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to VS technology without the expense or disruption of rewiring the entire building. VS control panels also support the ingenious R7116-2 zone module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intel- ligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Scalable lP and Cellular Communications Several popular third-party IP/Cellular communicators have been tested with the VS control panels and are compatibility listed to UL864. The IF/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/ Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the VS control panel compat- ibility documentation part number 3102354-EN for a full list of compatible communicators. A complete line of accessories VS Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (2) (3) (4) 0 T o 0 0 o o 0 o 0 04 08 o o 1oa.l Surface Mounting Holes (3) Backbox with 000r Attached Semi-flush mounting Holes )4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model 02 D3 D4 D5.06 D7 08 09 VS4 28.0 3.85 9.0 22.0 15.75 10.25 4.9 30.1 2.7 171.11 (9,8) (22.8) (55.8) (40.0) (26.0) (12.4) (76.4) (6.8) VS1 21.5 3.85 7.5 15.5 14.25 10.25 4.9 23.6 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (12.4) (59.9) (6.8) * Add 1-1/2 in. (3.81 cm) to Dl and D5 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. DATA SHEET K85005-0135 Not to be used for installation purpoac's. Issue 1.4 n vs1 Each VS1 panel ships with one device loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. j !pg - - 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (J 1) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries S System Layout VS4 Any combination of two single- orduajieviçelopro u/s Standard Loop: 250 points (one expansion slot) V-SLC2-2 Expander, Loop 1 of 2: 250 points Yp12sensoç q 1.25 dujesper loop (one expansion slot) V-SLC2-1 Expander Loop: 250 points (one expansion slot) V-SLC2-2 Expander, Loop 2 of 2: 250 points y~i~iog_per 169p -I- - - -- our lass B or two optional ClassA NAC ----- I - Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) RS-232 (SA-232)? rF Relays: Two Form C, one Form A Each VS4 panel has room for up to two device loop controller modules in any combination of single or dual 250-device loops. VS4 comes with one loop that supports up to 125 detectors and 125 modules. 5 6 7 1 81 10 13 I Page 3 of 8 DATA ser K85005-0135 Not to be use,21 for r'st I.to prpotm s Issue 1.4 Four Class B or two optional Class A NACs Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZ116-2 module Panel Layout Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. (2) Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (3) (Aux power 2) T33 • NO NC ® NO Q7NC 0 N Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. Alarm, trouble, and supervisory relay (TB3) The trouble relay is normally-open, held closed, and opens on any trouble event or when the panel is de-energized. The supervisory relay is normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications (4) Trcuble Sujervisory Alarm Smcke/Aux Alarm - Trouble Supervisory Type Form C I Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight sa-ially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style \') or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B wiring Class A wiring OLR OLR Wiring & Configuration Device loop The system provides one device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit VS4 VS1 specifications uevice loops one oiass tj or /\ one oiass ti or /A ioop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 pF, max impedance isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using an addressable notification appliance circuit (NAC) module and Genesis or Enhanced Integrity notification appliances. class wiring Class Awiring Loop Lane L-P Leap Loop co,d device device Loop cord Oov Line Notification appliance circuits (TB2) VS4 control panels come equipped with four notification appliance circuits. VS1 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications VS4 vS1 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 0 total, 0.35 iF max EOLR 15K0,1/2 W Synchronization Supported system-wide Class B Class A Channel 1 Channel 2 Channel 1 channel 2 + + Annunciator H TAnnupciator )CH1 IN C1 +) IN (-I )CHI CM -1 IN CH2 (+) IN +) IN CH2 I-I IN -) IN Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. 0 Page 4of8 DATA SHEET K850050135 Not to be used cgr installation purposes. Issue 1.4 Option Cards [1 Kidde VS Series panels are supported by a complete line of mod- ules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet pro- vides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The V-SLC2-1 is a single loop controller card that can be used with the VS1 as a replacement for the standard 64-point loop, or with the VS4 as a 250-point expansion module. The V-SLC2-2 is a 500-point dual loop controller card for the VS4 that provides two IDC circuits, each with 125 detector addresses and 125 module addresses. Specifications V-SLC2-1 V-SLc2-2 Device Addresses r VS4: one loop, 250 VS4: two loops, 500 device addresses . device addresses VS1: 64 addresses Wiring i Class B or Class A Operating Voltage 24 VDC Operating Current Standby: 55 mA Standby: 45 mA (fully loaded loop) Alarm: 80 mA Alarm: 70 mA Note. These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current I 0.5 A max. Max total loop 66 C) resistance Max total loop 0.5 pF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 kQ Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring To network The SA-ETH card provides a connection standard 10/100 Base T Ether- Network cabIe net network connection for connecting to an intranet, a local network, or the Internet. The card can be used to download On configuration programming from the VS-CU to the panel. The Ethernet card is installed on the plastic assembly and con- con- nects to the main circuit board Ethernet card via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5 of 8 RZ116-2 Remote Zone Interface Module The RZl16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. The RZ116-2 requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI1 6-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm current: 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA/ circuit Standby current for 3.9 k EOL (Canada) 5.7 mA' circuit Alarm current at nominal voltage 31.1 mA' circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 ko (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA' channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kQ Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), VS4, APS SIIEET K85005-0135 Not to be used 'or wsl Issue 1.4 (3) (2 I Zone ll Or 01 I 0i 0' 0. 01 LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs (4) SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the VS-CU. SADACT Phone line 1 The dialer phone lines connect Wi1ifl9 iFl To wail to connectors on the dialer's main hone line 2 phone jack circuit board. Phone me 1 con- Phone cables nects to connector J4 and phone (supplied) RJ31 jacks line 2 connects to connector J1. The SA-DACT queues mes- transmits them LDloa 1U1 sages and based on priority (alarm, 1:1 monitor). supervisory, trouble, and Activations are trans- miffed before restcrations. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-bACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBI( CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface The SA-232 card provides an RS-232 in- SA-232 wiring terface with VS panels. It can be used for GND (black wire) r TXD (white wire) connecting a printer to the control panel RXO (red wire) r to print system events. The card also can be used for connecting a computer to download a configuration program from VSto the fl fl the -CU control panel. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard E(A-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (VS1 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with VS1 control panels only. VS4 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16L-VS LED Display Expander (VS4 only) The D1 6L-VS LED Display Expanders provide LED annuncia- tion for up to 16 zones. It provides two LEDs for each zone. Two D1 6L-VS LED display expanders can be installed in each VS4 panel. 0 11 Page 6 of 8 DATA SHEET K85005-0135 Not to be used for instulLition purposes Issue 1.4 Notification appliance circuits VS1 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 64 device addresses (any combination of detectors and modules) Maximum I-taps: 63 (each device can be on its own branch) 2 Class B (Style 't), Class A (Style Z) optional 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 120 VAC, 60 Hz, 1.3Amax. 230 VAC, 50-60 Hz, 0.62 A max. 155 mA VS4 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), each loop supporting up to 250 device addresses (125 detectors and 125 modules max.). Addresses 1 t 125 are for detectors and addresses 126 to 250 are for modules Maximum T-taps/loop: 124 4 Class B (Style ) or 2 Class A (Style Z) 6.0 A FWR total at 120/230 VAC 60 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.97 A max. 172 mA Specifications Device loops Primary power Base panel current standby Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the VS1 and VS4 Series Compatibility List (P/N 3102354-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 lJF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet. If larger batteries are required, use a battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38X) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1B Ground fault impedance 0 to S kO Alarm contact Form C N.C. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.C. 24 VDC at 1 A (resistive toad) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing -. Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7of8 DATA SHEET K850050135 Not to b .j '01 1 p•tr*u'. jp' Issue 1.4 Ordering Information Part Description Kidde VS4 Fire Alarm Systems pr VS4-G Four loop system with one 250-point loop installed. 11 Ov, gray door. VS4-G-2 Four loop system with one 250-point loop installed. 230v, gray door. VS4-G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Technology that saves lives VS4-G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. VS4-GC Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. Contact us VS4-GD Four loop system, one 250-point loop installed. 110v, ray door, with dialer. Phone: 888.244.9979 (Option 4) VS4-GF Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. Email: kidde.fire@carrier.com VS4-G-FG Four loop system with one 250-point loop installed. 110v, gray door, Portuguese. Website: kidde-esfire.com VS4-G-SP Four loop system with one 250-point loop installed. ii 0v, gray door, Spanish. VS4-R Four loop system with one 250-point loop installed. ii 0v, red door. Kidde is a Carrier brand. VS4-R-2 Four loop system with one 250-point loop installed. 230v, red door. 8985 Town Center Pkwy, Bradenton, FL 34202 VS4-RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. SA-TR1M2 VS4 Flush mount trim, black. © 2020 Carrier VS1 Fire Alarm Systems All rights reserved. VS1-G One loop system with one 64-point loop installed. liov, gray door. VS1-G-2 One loop system with one 64-point loop installed. 230v, gray door. VS1-G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. VS1-G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. VS1 -GD One loop system, one 64-point loop installed. ilov, qy door, with dialer. VS1-GL One loop system, one 64-point loop installed. 110v, gray door, English Canada. VS1-GL-F One loop system, one 64-point loop installed. 110v, gray door, French Canada. VS1 -G-PG One loop system with one 64-point loop installed. 110v, gray door, Portuguese. VS1-G-57 One loop system with one 64-point loop installed. 11 Ov, gray door, Spanish. VS1 -R One loop system with one 64-point loop installed. liov, red door. VS1-R-2 One loop system with one 64-point loop installed. 230v, red door. VS1 -RD One loop system, one 64-point loop installed. 110v, red door, with dialer. SA-TRIM 1 VS1 Flush mount trim, black Option Cards V-SLC2-1 Expansion module, one 250-device loop. For VS4 only. V-SLC2-2 Expansion module, two 250-device loops, 500 devices total. For VS4 only. RZ116-2 Remote Zone Interface Module. 16 Class B lDCs, 2 Class B Output. Bracket included. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. VS1 systems only. D1 6L-VS LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display. For VS4 only. D8RY-VS Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For VS4 only. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5" - red. BC-1 Battery Cabinet. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 R Battery Cabinet - Red. 14.0" x 1825x 7.25". Holds two 12V24A batteries. GSA-REL Releasing Module BC-1 EQ Seismic hardening Kit for VS Series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools VS-CU VS Series configuration and diagnostics utility. 260097 R5232 cable, 4 conductor, D139 PC interface Page 8of8 DATA SHEET K850050135 Not to be usea for installation purpo.s, Issue 1.4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ . FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterfiow and sprinkler supervisory service. Models "EST" i01000G, iO1000G-2, iO1000GD, i01000R, iO1000R-2, i0I000RD, i064G, i064-GD, i064-R, i064-RD, i064G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VS1-G, VS1-GD, VS1-R, VS1-RD, VS1-G-2, VS1-R-2; VS2-G, V52-GD, VS2-R, V52-RD, VS2-G-2, V52-R-2, vs4-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FX1000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; RS232 Module D16L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XAL127; SLC Loop Driver io-SDC1, V-SLC2-1, FX-SLC1 Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *soopt *pT1S: System Printer *pT1p: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued July 01, 2020 Listing Expires June 30, 2021 Authorized By DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label APPROVAL: Listed as fire alarm control units for use with separately listed compatible iiitiating and indicating devices. *These control units meet the requiremert of UL 864. 9th Edition Standard. *102416 dc This listing is based upon technical data submtted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should no be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, instal ation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Annunciation Kidde (iii imrrim. Technology that saves lives R-Series Remote Annunciators RLCD, RLCD-C, RLED, RLED-C, RLED24, GCI 0 fI FnAhM - - 0sw Gwiti o c,.wr*E,id j Overview Kidde R-Series Annunciators are high-performance remote an- nunciators that provide status indication and common controls for compatible fire alarm control panels. This family of annunciators offers LCD or LED annunciation. Models are available with and without common controls. There are three R-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- ciator. The expander includes 24 pairs of LEDs that extend the capabilities of any of the annunciators. All annunciator models include status LEDs and an internal buzzer. Two models have an LCD text display, and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, four by twenty character per line, super-twist liquid crystal display. R-Series annunciators and expanders are mounted on a standard 4-inch square electrical box, using the included mounting ring. They can also be surface mounted in locking steel enclosures. Three different enclosures are available. A keyswitch and graphic annunciator interface is available for A-Series annunciator applications. The keyswitch enables or dis- ables common controls. The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic panel display. FDNY 7120-1657: COA 6020 0254 63424 Features LCD models feature large 4 x 20 character backlit LCD display LED models provide 16 pairs of LEDs for zone annunciation Available expander extends capability with 24 pairs of LEDs Up to two expanders may be wired to each annunciator Status LEDs and internal buzzer standard on all models Common controls available for LED and LCD display models Available keyswitch for disabling common controls Standard 4-inch square electrical box mounting Class B or Class A R5485 wiring standard One-, two-, and three-position enclosures available Graphic Annunciator interface, includes common control, indi- cators and 32 LEDS No programing required, set the address and unit receives all information from panel Pagel 0f4 DATA SHEET K850050128 Not to be used for installation purposes. Issue 1 S H H Hw H P— H R r• ci Fit— fl•— 1 ia F:l N c-am Li,iiuic,J ! (.J Keyswitch Specifications Maximum 5 Vdc voltage Maximum 200 mA current Mounting 2-1/2 in (64 mm) deep 1-gang box Termination Screw terminals Application R-Series annunciators communicate with the FACP on the RS-485 data riser. This can be configured for Class A or Class B commu- nication. Annunciators do not provide ground fault isolation. These annunciators are stand-alone units that can be powered by the FACP or by an approved power supply. RICO-C )llijI 4I)B*J / RICO Features by model RLCD RLCD-C RLEO24 RLED-C RLED24 Reset V I V - Ack/Silence I I V - Fire Alarm V V - Supervisory Ground Fault Trouble Controls Enabled V V V - Ack/Silence I I V - Reset I V - Signal Silence V I - Drill V I - Lamp Test LCD Display 16 * 24 ** Zone Active LEDs - - Zone Trouble LEDs - - 16 24 zones 13-16 may be selected as Supervisory on FX-64 and VS 1 zones 13-16 and 29-32 maybe selected as Supervisory on FX- 1000 and VS4 Annunciator Wiring Annunciator, Class A FACP Annunciator Annunciator RS-485 CHI In) IN 0 CHI (°) IN CHIc CHI IN OCHI l-)IN CHI - CHI 1°) OUT 0 CHI In) OUT CR20 CHI OUT CHI OUT CR2- CH2 IN OCH2ln)IN O CH2 I-IIN ØCH2 (-)IN LISTED 24 VDC CH2 (°) OUT 0 CH2 l'l OUT SUPPLY CH2 I-) OUT 0 CR2)-) OUT 24 VDC *Ø 24V IN 024v10)IN O24vI-II14 24 VDC - 0 Ø24v(-)IN 24V Ii-) OUT 0 24v Cc) OUT 24v I-) OUT 0 24v I-) OUT GROUND GROUND Annunciator, Class B FACP Annunciator Annunciator RS-485 CHI 101 IN CHI I'-) IN CHIn CHI I-lIlt CHI I-I IN CR1 - CHI 10) OUT 0 CR1 In) OUT CHI (-)OUT 0 CHI )-)OUT CH2 IN ),) 0 CH2 (n) IN CR21-) IN 0 CH2 I-) IN LISTED 24 VDC 0CH2 (0) OUT CH2 (n) OUT SUPPLY CH2 OUT )-) 0 CH2 I-) OUT 24 VDC * 24v 10-) IN 24v (') IN 24 VDC - 24V I-) IN 24v I-) IN 24V )r) OUT 0 24V 1*) OUT 24v I-) OUT 24Y )-) OUT GROUND GROUND Expander 1 11.1111 Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an LED-based graphic annunciator. The annunciator card supports 32 LEDs and 16 switches on the graphic panel display. It includes status LEDs and an internal buzzer. The graphic interface is supplied with snap track mounting. It is attached to a plastic mounting rail that requires two EIA panels. The annunciator communicates with the FACP on the RS-485 data riser. This can be configured for Class A or Class B commu- nication. The annunciator does not provide ground fault isolation. It is a stand-alone unit that can be powered by the FACP or by an approved power supply. Maximum 12 AWG Graphic Annunciator Interface Specifications wire size (2.5 mm sq) Alarm current 146 mA at 24 Vdc (with 36 LEDs ON) Contact Normally open Standby current 36 mA at 24 Vdc (with no LEDs ON) configuration Maximum current 10 mA per LED Page 2of4 DATA SHEET K850050128 Not to be used for installation purposes. Issue 1 Remote Keyswitch Annunciator LSRA-RI( L Annunciator Mounting I Annunciator Connections Annunciator Mounting slot DIP switch ANNUNCIATOR RS-485 RISER •••• Remote keyswitch terminals Expander cable terminals RS-485 riser terminals Power terminals Communication LEDs Expander Mounting slot Expander cable terminals DIP switch settings Switch Description and values Si to S5 The annunciator network address (in binary). Network The factory setting is for address 2. address Examples: 10000 = 1 01000 = 2 11000 = 3 00100 = 4 S6 Network OFF = 9600 baud (factory default setting) baud rate ON = 38,400 baud Expander cable terminals EXPANDER CABLE 0 0 No - S7 to S8 Not used MOUNTING RING I EXPANDER ELECTRICAL BOX fl Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white, painted finish. Each enclosure includes a security lock and two keys. The two- and three-position enclosures have wiring channels for cor- rect routing of interconnections. The enclosures attach to a standard electrical box, and provide a mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. R-ENC3 R-ENc2 9.5 in 24.1 cm 9.8 in 24.9 cm Dimensions (H x W x D) RA-ENC1 6.3 x 9.8 x 2.0 in (16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in (30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in (45.0 x 24.9 x 5.1 cm) Note: Allow approximately 2 inches (50 cm) clearance on both sides of the enclosure, to permit inserting and removing the key, and opening the door through 90 degrees. 6.0 in 15.2 cm ©LI R [0.9 in 2.3 cn 2.0 in 5.1 cm Page 3of4 DATA SHEET K850050128 Not to be used for installation purposes Issue 1 Specifications Kidde RLCD-c RLCD RILED-C RLED24 (.IflIrrIrflmflrn, Operating voltage 24 VDC, continuous. Standby current 99 mA 98 mA 28 mA 6 mA Technology that saves lives Alarm current 115 mA 113 mA 62 mA 34 mA Contact us... RS-485 communications .. Class A or Class B, 9600 baud - Email: kidde flre@fs utc corn Data wiring 18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot Web: kidde.corn/engineeredsysterns minimum). Maximum wire run is 4,000 ft. (1,219 m) Remote key switch circuit 5 VDC at 1 mA, power-limited, unsupervised 1016 Corporate Park Drive Mebane, NC 27302 Ground fault impedance 0 Kidde is a registered mark in the United States Power wiring 18 to 14 AWG (1.0 to 2.5 sq. mm) and other countries. Display area 4 lines of 20 characters each © 2018 Walter Kidde Portable Equipment. Dimensions (H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm) All rights reserved. Mounting North American 4-inch square electrical box or listed enclosure Agency Listing UL, ULC Operating environment Temperature: 32 to 120°F (0 to 49°C) Humidity: 0 to 93% RH, noncondensing at 90°F (32°C) Ordering Information Part Description Remote Annunciators K-RLCD LCD text annunciator without common controls. English. K-RLCD-R LCD text annunciator without common controls. English. Red. K-RLCDF LCD text annunciator without common controls. French. K-RLCD-C LCD text annunciator with common controls. English. K-RLCD-CR LCD text annunciator with common controls. English. Red. K-RLCD-CF LCD text annunciator with common controls. French. K-RLED-C 16-pair LED zone annunciator with common controls. English. K-RLED-CR 16-pair LED zone annunciator with common controls. English. Red, K-RLED-CF 16-pair LED zone annunciator with common controls. French. Remote Expanders K-RLED24 24-pair LED zone expander with expander cable and zone card insert. K-RLED24R 24-pair LED zone expander with expander cable and zone card insert. Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-MIR-SB Surface Mount Box - for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling common controls (Lock/Unlock). 27193-16 Electrical box, surface mount, white, single-gang, for RKEY. Page 4 of 4 DATA SHEET K85005-0128 Not to be used for installation purposes Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-1657:0254 Page 1 of 1 CATEGORY: 7120 --ANNUNCIATORS LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models RLCD, E- RLCD, RLCDF, RLCD-C, E- RLCD-C, RLCD-CF "LCD" Annunciators; RLED-C, E- RLED-C, RLED-CF "LED" Annunciators; RA-ENC1, RA-ENC2, RA-ENC3 Cabinets; RLED24 Remote Expander, LED24X Remote Annunciator Expander, Rkey Remote Key Switch; Gd, *GCINB and GCIX *Drivers Models RLCD, RLED, RLED24 may be followed by "R" which designates the color red. * GCI-24R, GCI-24Y, GCI-24G and GCl-24RY Remote LED Display Modules; "GCl-125/12R GCl-125/12Y, GCl-12S/12G, GCl-125/1213, GCI-125/12RY, GCl-125/12YY, GCl-125/12GY and GCl-CC Remote LED Display/Switch Modules; GCl-FP *Filler Plate Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annunciators and accessories for use with separately listed compatible fire alarm control units. "Rev 06-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division fKidde Technology that saves lives Remote Booster Power Supplies MIRBPS6A, MIRBPS10A Cara'..tg b Power Supplies and Accessories -E 183: S Overview The Booster Power Supply (MIRBPS) is a UL 864, 9th Edition list- ed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety, security, and access control applications. The MIRBPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the MIRBPS can support batteries totaling up to 6:5 ampere-hours in an external enclosure. The MIRBPS has four Class B (convert- ible to two Class A) NACs. These can be activated in one or two groups from the MIRBPS's unique dual input circuits. The MIRBPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The MIRBPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition )UOXX)Fire Alarm Systems UL636 (ANEr, UEHX7( Holdup Alarm Units and Systems UL609 (AOTX, AOTX7) Local Burglar Alarm Units and Systems UL294 (ALVY, UEHX7) Access control Systems UL365 (APAW, APAW7) Police Station connected Burglar Alarm Unts and systems UL1076 (APOU, APOU7) Proprietary Burglar Alarm System Units UL1610 (AMCX) central Station Alarm Unit ULC-5527 (UOXXC) Control Units, Fire Alarm (Canada) ULC-5303 (AOTX7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard Kidde keyed lockable steel cabinet with removable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Li Page 1 o 4 DATA SHEET K85005-0125 Not to be used for installation purposes. Issue 1 Dimensions D5 Q Top View 0 0 D2-. 14 D3 0 04— D4 —+0 S 5 Front View View 0 0 D6 0 CO All knockouts CL for 3/4 in conduit (1.9 cm) CD Dl Power-limited wiring area Application •The MIRBPS provides additional power and circuits for notification appliances and other 24 Vdc loads. It is listed for indoor dry loca- tions and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the MIRBPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the MIRBPS can still be activated upon command. A separate AC Fail contact is available on the MIRBPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the MIRBPS can be activated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The MIRBPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. MIRBPS NACs can be configured for a 3-3-3 temporal or continu- ous output. California temporal rate outputs are also available on certain models. This makes the MIRBPS ideal for applications re- quiring signaling rates that are not available from the main system. Dl 02 D3 D4 D5 D6 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) Engineering Specification Supply, where needed, Kidde MIRBPS Series Booster Power Sup- plies (MIRBPS) that are interconnected to and supervised by the main system. The MIRBPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The MIRBPS battery compliment shall be sized to match the requirements of the main system. The MIRBPS shall be capable of supervising and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications, and the capacity of 65 ampere-hours for access control applications. <<The MIRBPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The MIRBPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. MIRBPS NACs shall be convertible to a minimum of two Class A NACs. Each MIRBPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be provided with automatically restoring overcurrent protection. The MIRBPS shall be operable from the main system NAC and/or Kidde Signature Series control modules. MIRBPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, Califor- nia rate. Fault conditions on the MIRBPS shall not impede opera- tion of main system NAC. The MIRBPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Notes 1. Maintain 1/4-inch )6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. [21 Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. 131 Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. .In addition to the internally generated signal rates, the MIRBPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The MIRBPS enclosure has mounting brackets for up to three Signature modules to the right of the circuit board. Route AC supply through these knockouts only (Nonpower-limited and supervised) Page 2of4 DATA SHEET K850050125 Not to be used for installation purposes Issue 1 Notification appliance circuit EOL 47 K EOL 47 K -11+ 109 CC1(S) module 00 UL listed EOL 15 KW CC 1 (S) module 00 [3] NAC circuit I To next signaling NAC Circuit ____ _____________ J > device, booster, or EOL resistor ) C/) I CD 7C!D ) NAC output #1 Fire Alarm I , ) NAC output #2 CD ) NAC output #3 control Panel ) NAC output #4 I Booster Power Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAC end-of-line resistors are not required to be installed at the boosters terminals. This allows multiple boosters to be driven from a single NAC circuit without the need for special configurations. Configuring the Booster for AC Power Fail delay operation* TB1 Notification appliance circuit (NAC) NAC1/ + UL listed AUX1 NAC2/ + AUX2 - Notification appliance circuit (NAC) NAC3/ + UL listed EOL15kO NAc4i EOL 15 kO AUX3 - AUX4 - 200 mAAUX Continuous lN Sense 1 COM Eff OUT Eff IN RW Sense 2 COM 3 OUT Li1 NO f Trouble COM E NC TB2 0 Data in from previous device or Signature controller Multiple CC1 (S) modules using the MIRBPS's sense inputs TB1 Notification appliance circuit (NAC) NAC1/ + UL listed EOL 15 KW 200 mAAUX Continuous co IN Sense 1 COM Eff OUT Eff IN Sense 2 COM Eff OUT Fff NO Trouble COM NC TB2 0 EOL 47 kO CC1(S) module [1 ][3] 00 lii Disable the MIRBPS's ground fault jumper CT previous device next device Data in from j L-1 Data out to moul[4]II or Signature I 1 controller Data out to *The Booster supports AC Power fail delay of three hours via its trouble contact when next device dip swtch SW2-6 is on. All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS TB 1 24 V C / /// + - 12 V Security EOL urlcvice Security monitoring device de device To next device or end • Page 3of4 DATA SHEET K850050125 Not to be used for installation purposes Issue 1 [I Specifications 1(idde Model ______ 6.5 amp Booster 10 amp Booster AC Line Voltage 120VAC or 220-240VAC 50/60Hz 120VA0 or 220-240VAC 390 watts 580 watts Technology that saves lives Notification Appliance 3.0A max. per circuit @ 24Vdc I 3.OA max. per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACslnominal lOA max total all NACs Contact us... Trouble Relay 2 Amps @ 30Vdc Email kidde fire@fs utc,com Auxiliary Outputs -. Four configurable outputs replace NAGS 1, 23 or 4. as auxiliary Web: kidde.com/engineeredsystems - -- - -- - outputs and 200 mA dedicated auxtiary. (See note 2.) - - 1016 Corporate Park Drive Input Current (from an existing NAG) 3mA @ 12Vdc, 6mA @ 24Vdc Mebane, NC 27302 Booster Internal 70mA + 35 mA for each circuit set to AUX Kidde is a registered mark in the United States Supervisory Current and other countries. Booster Internal Alarm 270mA © 2018 Walter Kidde Portable Equipment. Current All rights reserved. Signature Mounting Space Accomodates three two-gang modules. 10 Amp Hours (2 of 12V1 OA) in cabinet up to 24 Amp hours with ex- Maximum Battery Size ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing © 32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model MIRBPS°CM provides selection for California rate, in place of temporal. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Number Description Shipping Wt. lb (kg) MlRBPS6A 6.5 Amp Booster Power Supply 13(5.9) MIRBPSGAC 6.5 Amp Booster Power Supply (ULC) 13(5.9) MIRBPS6A'230 6.5 Amp Booster Power Supply (220' 13(5.9) MIRBPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) MIRBPS10A 10 Amp Booster Power Supply 13(5.9) MIRBPS10AC 10 Amp Booster Power Supply (ULC) 13(5.9) MIRBPS10/V230 10 Amp Booster Power Supply (220V) 13(5.9) MIRBPS1 0CM 10 Amp Booster Power Supply with California rate 13(5) Related Equipment 12V6A5 7.2 Amp Hour Battery, two required 3.4 (1.6) 12V1 OA 10 Amp Hour Battery, two required - 9.5(4.3 3-TAMP Tamper switch Notes: BC-1 Battery Cabinet (up to 2 -40 Amp Hour Batteries) 58(26.4) 1. Requires installation of separate battery BC-2 - Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) cabinet. BC-1 EQ Seismic hardening Kit for BC-1 cabinets. Includes battery hard- MIRBPS supports batteries greater than ening order BC-1 enclosure separately. 24 Amp hours for access control applica- BPSEQ Seismic kit for MIRBPS6A or MIRBPS1 0 Booster Power Sup- tions only. For earthquake anchorage, including plies. See note 3. detailed mounting weights and center of 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) gravity detail, please refer to Seismic Ap- 1 2V24A 24 Amp Hour Battery, two required (see note 1) 20 (9.07) plication Guide 3101987-EN. Approval of 2V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) panel anchorage to site structure may re- quire local AHJ, structural, or civil engineer 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40 (18.14) review. 12V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) Page 4 of 4 DATA SHEET K85005-0125 Not to be used for installation purposes Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1483:0174 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MlRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models MlRBPS6A, MIRBPS10A, MIRBPS6A/230, and MIRBPS10A/230 remote booster power supplies. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1657:0229 *Rev. 6-9-11 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division A 1 CELLULAR ALARM TG=7FS COMN'lUNICATOR FOR 3G/4G NETWORKS TELGUARD ô COMMERCIAL FIRE PRODUCT FEATURES :- Meets UL 864 requirements for sole, primary or backup path communications. :• Provides RMR protection by leveraging technology that operates on 3G/4G networks. :- Supports listen-in, two-way voice verification over cellular. :- Minimizes false alarms by providing dual paths for self-tests. Falls back to 2G (GSM) if a 3G/4G network isn't available. { The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each Iandline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7F5 can be installed as the sole path for commercial fire installations. For existing installations, all Iandlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. Telguard Online Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7 This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. Telguard Cellular Service Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Advanced Reliability Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms Automatic self-tests with central station notification ensure the cellular system is operating. Available relay output for tripping the alarm control panel when a trouble condition occurs. A- 44 CELLULAR ALARM vjmv TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS TELGUARD Power ice 6OmA (Standby)..,'n , I 2 56 (Tansrr$$ *J4 Transformer: ,12VA'8On.:'t. UL listed plug in Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for Radio Transceiver . superior in-building penetration. 3G cellular radio. GSM85OMHz Class 4(2athY Telguard products are easy to install economical and UL Listed *5 GSM 1900MHz: Class 1 (1,f.W.) UMTS WCDMA FDM~b Accessories Antenna 9 dipolewith2dBiga ACD 12 ACD 35 ACD 50 ACD 100 12ftofcableandertüig 12/35/50/100 feet of low loss, high performance cable. bracket. . ,,. • HGD-0: High gain directional antenna. FCC part 15, 22, 24 and 68 compliant. EXD-0: External antenna. Physical Details TG-7FS: 7.5" H x 11.5" Shipping Weight: 8lbs Operating Environ'ine.nd 0°C to +50°C; upto 95%fiumidity (non-condensing): :, UL Listings Standard Features Commercial Fire Commercial Burglary Residential - - - ' 864 • Control units & 365 • Police Station 985 • Household fire Full data reporting. , accessories for fire connected burglar warning systems Automatic sif test &iy) alarm systems alarm units and -. systems Power supply 1610 Central station burglar Locking red metal enclos(ire alarm units Two programmab,4je suj'ls Line security servcies trip outputs................. , For the most current product specifications and UL Listings visit www.Telguard.com. Alarm format support forSlA2v Contact ID, pulse (3x1, 4x2) modem lle,&llla2 TRONIC ,DM ' Telephone line it built in LJ E ASSOCIATIO A RITY N with Standard Line Secui9ty:''. "' NFPA LISTED INTERNATIONAL Telguard, a Division of Telular Corporation • Cumberland center iv • 3225 Cumberland Blvd • Suite 300 . Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright c'2012 Telular Corporation . All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA001, TG7LM01, TG7LA002, TG7LAF01, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division installation & Inspection Notes L Lock w/ 3/4" barrel Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! S Fire Document Box The FDB is the perfect fit to meet the demanding code requirements today. NFPA 72 10.18.2.1.2.8 states that a cabinet must be "prominently labeled 'FIRE ALARM DOCUMENTS'." An internal galvanized sleeve holds the documents safely and securely. The sleeve is easily removable to allow storage of a 1.5" 3 ring binder or other media. The galvanized sleeve also contains 2 hooks for key rings or thumb drives, a place for several business cards, a cutout for a 1.4 Oz. can of test gas and a slot where a standard CD "jewel" case can be stored. Access to the documents is via a high security lock with a 3/4" Standard Features: barrel. 1] Overall Dimensions are: Key Ring 12" Wide x 13.1" High x 2.25" Deep Hooks 3/4" barrel lock to secure door Piano Hinged Door w/Notes Sticker Removable document holder can Detector hold 1" of 8.5" xll" paperwork Smoke Powder Coat Red Finish 16 Gauge CRS construction Embossed: Key Ring Hooks Business Card Holder CD Case Slot 1.4 Oz. can of detector smoke Custom screening with your logo =__ AW-W 1~ ISO 901 LIJ REGISTERED NFPA Made In\U.S.A. COMPANY Space Age Electronics, Inc. 2008 ED0447 LT1 0505 Rev.A Oct. 2010 1/2 Business Card Holder CD Jewel Case NOTES: System Access: System Level Code EROS) 1110507 RaY. A FOR floor ShARI, ..#. Ssor,)o. E%,.,00,, I,.. 58C-- SlAt,) M50174) 1114851125 Notes Sticker inside FDB Door fl JJPSPACE AGE ELECTRONICS, INC. Specifications: The Fire Document Box (FDB) shall be constructed of 16 gauge cold rolled steel (CRS); it shall be painted with a durable red powder coat paint. The front door shall be lettered with the words "FIRE ALARM DOCUMENTS" in White indelible letters 1" in height. The door of the FDB shall be locked with a keyed lock, 3/4" barrel. The cabinet shall contain a 16 gauge galvanized CRS sleeve. This sleeve shall allow for the storage of 1" of paper, test and inspection records, manuals and other important documents. The sleeve shall also facilitate the hanging of key rings and thumb drives (for data storage) along with business cards and space for a CD "jewel" case. The unit shall also contain a 1 .4oz can of smoke detector test gas. Adheared inside the door shall be a "Notes" label for the recording of valuable information such as AHJ approvals, various system codes and the location of hard to find devices. If so desired, the internal sleeve (held in by 2 wing nuts) may be removed and the space used to insert a 1.5" 3 ring binder. Ordering Information: Part # Description SSU00672 FDB Fire Document Box SSU00673 FDB Custom Logo/lock (ask for Form FDI 0498 to order custom box) CKI Replacement 1.4 Oz Test Gas This document is subject to change without notice, see doc # ED0479 for legal disclaimer E00447 LT10505 Rev.A 2/2 Space Age Electronics, Inc. www.lsae.com . 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ls~'qv LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, lFX/A and IFX/D enclosures. Models A,--E-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use witl listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. S 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division '- P Intelligent Initiating Devices Kidde Technology that saves lives Intelligent Smoke Detector KI-OSD Overview The Kidde Intelligent Optica Series KI-OSD smoke detector brings advanced optical (photoelectric) sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs. Like all Kidde Intelligent Optica Series detectors, the KI-OSD is an intelligent device that gathers analog information from multiple optical sensors, converting this data into digital signals. Utilizing dual optical wavelengths combined with multiple detection angles, the KI-OSD differentiates particles that are not representative of actual smoke. Particle data is input into digital filters which feed a series of ratios removing signal patterns that are typical of nuisance sources, thus reducing unwanted alarms. To make an alarm decision, the detector's on-board microprocessor measures and analyzes all optical sensor readings and compares this information to preprogrammed settings. - ow ,wow - 1 'Kiddc / 0 a 1212-16b(: 0511 Standard Features Patented multi-criteria optical smoke sensing technology Wide 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) smoke obscuration Uses Existing Wiring Integrated nuisance rejection reducing unwanted alarms from general cooking particulates Listed to UL 268 7th edition Automatic Device Mapping Up To 250 Total Kidde Intelligent Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Environmental compensation Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status LED Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Page 1 of 4 DATA SHEET K85001-1001 Not to be used for installation purposes Issue I Application The Kl-OSD detects particles from a wide range of combustion sources and will trigger an alarm when smoke density in the chamber reaches preprogrammed level. Thanks to its high- performance patented reflective response technology, the smoke sensor responds quickly and reliably to a wide range of fire types, including both fast and slow burning fires fueled by combustibles typically found in modern multi-use buildings. Compatibility The Kl-OSD detector is compatible only with control panels using a Kidde Intelligent Loop controller. Installation Kidde Intelligent Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch Self-locking tab square electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1 1-gang boxes with 60.3 mm -. LED Indicator fixing centers. See mounting base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Kidde Intelligent Series detector constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning, etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitivity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity measurements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are accessible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The KI-5B4, KI-RB4, and KI-lB4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the Kl-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The Kl-ABST mounts to a 4 inch square box only. (", ~Zr_, KI-ABST/ABDTIABLT KU-SB KI-IB Kl-RB KI-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED GSA-LED - The remote LED connects to the KI-SB or KI-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Suppliec with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Kidde Intelligent Series sounder bases are designed for use where localized or group alarm signaling is required. KI-ABST bases provide sounder capability to Kidde Intelligent Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire- plus-CO mode. Kt-ABDT bases provide sounder capability to Kidde Intelligent Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. S Kl-ABLT bases provide 520 Hz low frequency sounder capability to Kidde Intelligent Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. The KI- ABLT is suitable for applications requiring low frequency audible tones. Page 2 of 4 DATA SHEET K85001-1001 Not to be used for installation purposes Issue 1 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. • ABS7 ABDI ABLT sounder bases Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. _.-,_______'\__I________•----..-'.... Standard Detector Base, Kl-SB, Kl-5B4 KI-ABST KI-ABLT: This is the basic mounting Kl-ABDT Kl-ABLT: Jumper cuts Output Mode Default = Fire base for KIDDE Intelligent Series _________ Remote LED Volume Setting Cut/remove jumper Default = High for Fire plus CO detectors. The GSA-LED I Max resistance Cut/remove Remote LED is supported by J per 1+ must not exceed jumper low dB KI-ABST: Tone Setting this Base. aura- oura- oarav Default = Temporal sia sin- oar a aisar Cut/remove jumper Term Description I for Steady I 1 Not Used I 0 2 DATA IN/OUT (+) I . I 3 Not Used I 4 DATAIN(-) I 4 Remote LED (-) I DATAlNl- l DATAOUTlI I 5 Remote LED (+) I I 6 Not Used 7 DATA OUT I DATA IN I--I DATA OUT -cl From power Supply - 24 Vdc in 24 Vdc out From SLC or To Next Device or previous base + - + To next base or EOL relay Previous Device Isolator Detector Base, KI-IB, Kl-1113 Data in - From Kidde Controller or to next Kidde device4 - Data out + previous device This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED. - at 10 msec intervalsbeginni on one side of the Class A S circuit nearest the loop controller, the isolators DAT close to provide the ..+ .-..-.I...c.-... .5.-.., The isolator operates as follows: - a short on the line causes all isolators to open within 23 rr Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. This detector does not sense fires in areas where smoke cannot reach the detector. Smoke from fires in walls, OUT roofs, or on the opposite side of closed doors may not reach the detector. In Canada, install according to CAN/ULC-5524 Standard for the Installation of Fire Alarm Systems, CSA C22.1 Canadian Electrical Code, and the local authority having jurisdiction. the line with power. From Kidde Controller or Previous Device - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. OUT (+) To Next Device Term Description 1 Not Used 2 DATA IN/OUT (a) 3 DATA IN(-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used Relay Detector Base, KI-RB, Kl-RB4 This base includes a relay. Normally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) © 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The Kl-RB can be operated as a control relay if programmed to do so at the control panel. The relay base does not support the GSA-LED Remote LED. Ns,rnoty- Normally- DATA INC-I \-rr LA our I-I DATA IN Iv) DATA OUT 1*) From Kidde Controller To Neat Device or Previous Device Term Description I Normally Open CONTACT RATING 2 DATA IN/OUT (+) 1.0 Amp @30 VOC 3 Common (Pilot Duly) 4 5 6 7 DATA IN (-) Not Used Normally-Closed DATA OUT I-) Page 3 of 4 DATA SHEET K85001-1001 Not to be used for installation purposes Issue 1 I 22 1 ' Li . lNwdioHOa 0 © 2020 Carrier All rights reserved. Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 45 IJA Smoke Sensitivity Range UL/ULC: 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) obscuration Vibration evel 10 to 35 Hz, with an amplitude 010.01 in. Air velocity 0 to 4,000 ft/mm (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testifire 2000 Operating environment 32 to 120°F (0 to 49°C), 0 to 93 RH, noncondensing Construction High Impact Engineering Polymer, White Storage temperature -4 to 140°F (-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529, UL 268-7, UL 268A, CSFM, FM Specifications 4 J• Pr Kidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 Dimensions S z am Page 4 of 4 Ordering Information Catalog DscriptiOn Ship Wt. Number lbs (kg) Kl-OSD Intelligent Optical Smoke Detector 0.4(0.16) Accessories Kl-SB Detector Mounting Base - Standard Kl-SB4 4-inch Detector Mounting Base c/w Trim SKirt Kl-RB Detector Mounting Base w/Relay Kl-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt C.2 (.09) Kl-IB Detector Mounting Base w/Fault Isolator Kl-I134 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt GSA-LED Remote Alarm LED KI-ABST Audible (Sounder) Base for Fire Detectors 0.3(0.15) Kl-ABLT Low Frequency Audible (Sounder) Base for CO and/or Fire Detectors 0.3 (0.15) Kl-ABDT Audible (Sounder) Base for CO and/or Fire Detectors 0.3 (0.15) GSA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) GSA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) GSA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleanino Tool DATA SHEET K85001 -1001 Not to be used for installation purposes Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IJJ LISTING SERVICE LISTING No. 7272-1657:0511 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models SIGA-OSD and *KIOSD Intelligent Optical Smoke Detectors. Analog Addressable Photoelectric Smoke Dectector. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models beginning with SIGA are marked Edwards. *Models beginning with KI are marked Kidde. APPROVAL: Listed as intelligent optical smoke detectors. *Model KI-OSD is for use with listee's models VS1, VS2, and V54(7165-1657:0244); VM-1 (7165-1657:0309) fire alarm control units. *Model SIGA-OSD is for use with listee's models EST4 (7165-1657:0508); EST3 . (7165-1657:0186); i064, iOl000 (7165-1657:0244); EST3X (7165-1657:0306); Quickstart fire alarm control units. Refer to listee's installation, operation, and maintenance manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Revision 03-23-20 VVWV This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division 040 Pr K*Idde Technology that saves lives cDDE Oi ' Intelligent Initiating Devices [_Compatible with VS&VM control systems Intelligent Heat Detectors KI-HRD, KI-HFD S853 KI-HFD shown 0 Overview The KI Series smoke detectors bring advanced sensing technol- ogy to a practical design that increases efficiency, saves installa- tion time, cuts costs, and extends property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while the latest thermister technology makes these detectors ideal wherever dependable heat detection is required. The KI-HRD is an intelligent fixed temperature/rate-of-rise fire detector. It monitors the temperature of the surrounding air and analyzes the data from the sensor to determine whether to initiate an alarm. The rate-of-rise heat function quickly detects a fast, flaming fire. The fixed-temperature heat function detects fire when the air temperature near the detector exceeds the alarm point. The KI-HFD is an intelligent fixed-temperature heat detector that contains a fixed-temperature heat sensor rated at 135 °F (57.2 °C). It does not have a rate-of-rise function. The heat sensor moni- tors the temperature of the air in its surroundings and the detector analyzes the data to determine when the air temperature near the detector exceeds the device's alarm point. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next generation heat sensing technology 135 °F (57 00) fixed temperature alarm point (HRD and HFD) 15°F (8.3 °C) per minute rate-of-rise alarm point (HRD) Uses existing wiring Automatic device mapping Sensor Markings Provide Easy Testing Identification Up to 250 total devices per loop Non-volatile memory Electronic addressing Bicolor (green/red) status LED Cover marking for easy identification during testing Standard, relay, fault isolator, and audible mounting bases 50 foot (15.2 meter) spacing Page 1 of 4 DATA SHEET k85001-0647 Not to be used for installation purposes Issue 1.1 S Application Compatibility The KI-HRD detector is compatible with Kidde VS and VM series panels. Installation KI Series detector bases mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square elec- Self-locking tab trical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 I mm fixing centers. See mounting LED Indicator base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each KI Series detector constantly runs self-checks to provide important maintenance in- formation. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory. Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Accessories Detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The KI-SB4, KI-RB4, and KI-1B4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the GSA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The KI-ABST mounts to a 4 inch square box only. KI-ABST/T/LF KI-SB KI-IB KI-RB GSA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED GSA-LED - The remote LED connects to the KI-SB or KI-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. GSA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - KI Series sounder bases are designed for use where localized or group alarm signaling is required. KI-ABST bases provide sounder capability to KI Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. Kl-ABDT bases provide sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. Kl-ABLT bases provide 520 Hz low frequency sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-13T4 Temporal Pattern Generator. The KI-ABLT is suitable for ap- plications requiring low frequency audible tones. Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safe- guards with the local fire protection specialist. This detector does not sense fires in areas where heat cannot reach the detector. Heat from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector. This heat detector by itself does not provide life safety protec- tion Use this detector with ionization and/or photoelectric smoke detectors. This detector does not detect oxygen levels, smoke, toxic gases, or flames. Use this device as part of a broad-based life safety program which includes a variety of information sources pertaining to heat and smoke levels, extinguishment systems, visual and audible devices, and other safety mea- sures. Independent studies indicate that heat detectors should only be used when property protection alone is involved. Never rely on heat detectors as the sole means of fire protection. .The KI-HRD combination fixed temperature/rate-of-rise heat de- tector provides a 15 °F (9 °C) per minute rate-of-rise heat sensor for the detection of fast-developing fires, as well as a 1 35°F (57°C) fixed temperature sensor for slow building-fires. The KI-HFD fixed temperature detector provides a 135°F (57°C) fixed temperature sensor for slow building-fires. Page 2 of 4 DATA SHEET K85001-0647 Not to be used for installation purposes. Issue 1.1 Typical Wiring The detector mounting bases accept #18 AWG (0 75mm2), #16 (1.0mm2), #14 AWG (1 .5mm2), and #12 AWG (2.5mm2) wire sizes. Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, KI-SB, KI-SB4 This is the basic mounting base for Kidde KI Series detectors. The GSA-LED Remote LED is supported by this Base. Term Description 1 Not Used 2 DATA IN/OUT (+) 3 Not Used 4 DATA IN)-) 4 Remote LED (-) 5 Remote LED )+) 6 Not Used L7 DATA OUT)-) Remote LED I Maxresistance per wire I I must not exceed r4f- Ohms DATA IN I-) • DATA OUT I-) DATA IN Iv) DATA OUT (v) From Signature Controller To Next Device or Previous Device Isolator Detector Base, KI-IB, KI-1B4 This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED. The isolator operates as follo - a short on the line causes all lators to open within 23 mse - at 10 msec intervals, beginning on one side of the Class A DA] circuit nearest the loop controller, the isolators close to provide the DA1,- next isolator down the From Signature Controller or Previous Device line with power - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Relay Detector Base, KI-RB, KI-RB4 Normally- Normally- This base includes a relay. Nor- mally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The KI-RB DAI can be operated as a control relay if programmed to do so at DATA IN tot DATA out tot to Next Device the control panel. The relay base Signature Cactiute, orPrevious Device does the GSA-LED Term Description not support 1 Normally Open Remote LED. CONTACT RATING I 2 DATA IN/OUT 1.0 Amp 30 VDC I common (Pilot Duty) I 4 6 I 7 DATA IN Not Used Normally-Closed DATA OUT).) Audible Sounder Bases, Fire Mode ABDT ABS7 ABLT sounder bases KI-ABDT. 0 0 KI-ABLT: KI-ABST, KI-ABLT Jumper cuts: Output Mode Default Fire Volume Setting Cut/remove jumper for Default High Fire plus CO Cut/remove jumper for KI-ABST: low dB Tone Setting 00r0- G- DATA. Default = Temporal 55. -OUT IN isxuT cut/remove jumper for Steady ________________ KI-ABDT: Not used 24Vdcin From power supply - 24 Vale out or previous base + + To next base or EOL relay Data in - Data out From KI Device Controller to fleet KI Series device or previous device - + OUT (+) To Next Device OUT (-) Tsrm Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN)-) 4 Not Used S Not Used S DATA OUT 7 Not Used S fl Page 3of4 DATA SHEET K85001 -0647 Not to be used for installation purposes Issue 1.1 17-1 Dimensions Kidde Technology that saves lives 1H Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Gamer brand. 8985 Town Center Pkwy, Bradenton, FL 34202 S © 2020 Carrier Specifications All rights reserved. KI- HRD Kl-HFD Operating voltage 15.20 to 19.95 VDC Normal operating current 51 pA Alarm current 68 pA Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Rate-of-rise rating 15°F/mm (8°C/mm) I NA Fixed temperature rating 135°F (57.2°C). Actual alarm point 129 to 141°F (53.9 to 60.6°C). Maximum spacing 50 ft. (15.2 m) centers Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testifire 2000 1 Testifire 2000 S Operating environment 32 to 100°F (0 to 38°C), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White Storage temperature -4 to 140°F (-20 to 60°C) Agency Listings CAN/ULC-S530, UL 521 1 CAN/ULC-S530-M91, UL 521 Ordering Information Catalog Ship Wt. Description Number lbs (kg) Kl-HRD Intelligent fixed temperature/Rate-of-rise heat detector 0.4(0.16) Kl-HFD Intelligent fixed temperature heat detector Compatible Bases Kl-SB Detector Mounting Base - Standard - KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt Kl-RB Detector Mounting Base w/Relay 0 2 09 KI-RB4 - 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt KkB Detector Mounting Base w/Fault Isolator - - KHB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt Kl-ABST Audible (Sounder) Base for Fire Detectors Kl-ABLT Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) KI-ABDT Audible (Sounder) Base for CO and Fire Detectors GSA-LED Remote Alarm LED (not for EN54 applications) GSA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) GSA-TS Trim Skirt (optional for non 4-inch bases) Page 4 of 4 DATA SHEET k85001-0647 0 Not to be used for installation purposes Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1657:0333 Page 1 of 2 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models SIGA-HFD, SIGA-HRD, *SIGAH2D *SIGlHFD *SIGI-HRD, *KIHFD *KIHRD and *KIRHD Analog Addressable Heat Detectors. Model SIGA-HFD is a 135°F fixed temperature heat detector. Model SIGA-HRD is a combination 15°F rate of rise/135°F fixed temperature heat detector. Models SIGA-HFD, SIGA-HRD, *SIGA-H2D, *sIGlHFD *SIGIHRD *KIHFD *KIHRD and *KIR HDAnalog Addressable Heat Detectors. Model SIGA-HFD is a 135°F fixed temperature heat detector. Model SIGA-HRD is a combination 15°F rate of rise/135°F fixed temperature heat detector. *Models SIGI-HFD and SIGI-HRD are similar to Models SIGA-HFD and SIGA-HRD except for isolation circuitry. *Models Kl-HFD and Kl-HRD are identical to Models SIGA-HFD and SIGA-HRD except for trade name. *Mode KIR-HD is similar to Model SIGA-HFD except for control panel compatibility. Model SIGA-H2D is similar to Model SIGA-HFD except has a programmable threshold. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-HFD, SIGA-HRD, SIGA-H2D, SIGI-HFD and SIGI-HRD are urder the Edwards brand. *Models KI-HFD, KI-HRD and KIR-HD are under the Kidde brand. APPROVAL: Listed as an analog addressable heat detectors. *Models KI-HFD and Kl-HRD are for use with listee's Models VS1, VS2 and VS4 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657:0309) fire alarm control units. *Models SIGA-HFD, SIGA-HRD, SIGA-H2D, SIGI-HFD, SIGI-HRD, are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); i064, i05OO and iOl000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions andior other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7270-1657:0333 Page 2 of 2 *Model KlR-HD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control unit. Models SIGA-HFD, SlGA-HRD, SIGA-H2D are for use with listee's bases; Models SlGA-SB, -SB4, -RB, -RB4, -IB, -1134 (CSFM No. 7300-1657:0120); SlGA-AB4G (CSFM No. 7300-1657:0222); SlGA-AB4GT (CSFM No. 7300-1657:0307) and SlGA-AB4G-LF (CSFM No. 7300-1657:0322). *Models SlGl-HFD and SlGl-HRD are for use with listee's bases; Models SlGl-AB4G (CSFM No. 7300-1657:0222); SlGl-AB4GT (CSFM No. 7300-1657:0307) and SlGl-AB4G-LF (CSFM No. 7300-1657:0322). *Models Kl-HFD, Kl-HRD and KlR-HD are for use with listee's bases; Models Kl-ABST (CSFM No. 7300-1657:0222), Kl-ABDT (CSFM No. 7300-1657:0307) and Kl-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. is *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division (1) SLC IN from previous device. SLC OUT to next device. + (2) To GSA-LED. Maximum resistance per wire is 100. 3) Table 1: Base terminals Number Description Number Description 1 Not used 4 Remote LED - 2 SLC IN/OUT + 5 Remote LED + 3 Not used 6 Not used 4 SLCIN - 7 SLC OUT - iKidde (aarni.mrr KI-SB Detector Base Installation Sheet To wire the Kl-SB: Wire the detector base as shown in Figure 1. Break the wire run at each terminal. Do not loop the signaling line circuit field wires around the terminals. Insulate the shield with electrical tape. Figure 1: Wiring the Kl-SIB Description The Kl-SB is the standard base for Signature Series detectors. It connects the detector to the signaling line circuit (S _C:), and provides wiring terminals for connection to a GSA-LED. Installation Caution: Risk of equipment damage. To prevent damage to the base, do not overtighten the base mounting screws or wire terminal screws. Refer to "Specifications" on page 2 for torque values. Refer to Technical Bulletin P/N 3102483-EN for location and spacing requirements. To install the Kl-SB: Mount the Kl-SB on a compatible electrical box using the screws provided with the elettrical box. Wire the base as shown in the 'Wiring" section. Write the address assigned to the detector on the label provided and apply the label to the inside rim of the base Use a GSA-TS trim skirt to finish the installation as needed. Wiring Caution: Risk of system failure. Electrical supervision requires that the wire run be broken at each terminal. Do not loop the field wires around the terminals. Notes Shielded wire is required only in environments with very high electrical noise. Shields, if used, must be continuous and insulated from ground. For Class B wiring, there is no shield connectior to ground at te last device. KISB 7 11111 93016 05455 5 © 2017 United Technologies Corporation 1/2 P/N 3102481-EN REV 001 • ISS 10AUG17 Specifications Wire size Screw torque Base mounting Terminal Housing Compatible detectors Accessories Compatible electrical boxes Operating environment Temperature Relative humidity Technical bulletin 12 to 18AWG (1.0to 4.0 mm2) Sizes 16 and 18 AWG are preferred 18 Ibf-in (2.0 Nm) max. 12 lbf-in (1.4 Nm) max. High-impact engineering polymer, white Signature Series detectors GSA-TS Four-Inch Box Trim Skirt/Ring North American single-gang box Octagon box 3-1/2 in. (89 mm) by 1-1/2 in (38 mm) deep Octagon box 4 in. (102 mm) by 1-1/2 in. (38 mm) deep European single-gang box 75 mm with 60.3 mm fixing centers BESA box with 60.3 mm fixing centers 32 to 120°F (0 to 49°C) 0 to 93% noncondensing P/N 3102483-EN Regulatory information North American CAN/ULC-S529-09, UL 268, and UL 521 standards Contact information For contact information, see www.kiddelifesafety.com. 2/2 P/N 3102481-EN REV 001 ISS 10AUG17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL M,41~x FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7300-1657:0120 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Detector Bases. Base models are as follow: Models 5963B, 5964 B/BR, 624113-002, 624913-001, 6251, 625113-001A, -001, -002, -003, -004, 6251 B-1 00, -200, -R1 00, -R200 and 6251-2 Models 6251 B-aOl, -002, -003 and -004 are suitable for releasing device service. Models P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047. Models SIGA-113, -I134, -RB, -RB4, -SB, -5B4 and -AB4. *Models Kl-IB, -I134, -RB, -R134, -SB and -5B4. The -RB series are suitable for releasing device service. *Model SlGl-SB and SIG[-SB4. Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. *KI are under the Kidde Brand. SIGA* and SlGl* are under the Edwards Brand APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 *Rev 05-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should no: be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, instal at on instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division GSA-M278 n5L X7150-1483, MEA S2318 or K*Idde D Intelligent Initiating [_CompatithV1&VMcontrolsystems • Technology that saves lives Manual Pull Stations GSA-M270, GSA-M270P, GSA-M278 Overview The GSA-M270 and GSA-M278 series Manual Pull Stations are part of Kidde's Signature Series system. The GSA-M270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder-coat paint complemented by aluminum colored stripes and markings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a posi- tive alarm, ensuring protection plus fool-proof operation. Presignal models (GSA-M270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. Kidde's double action single stage GSA-M278 station is a contem- porary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked 'LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance GSA-M270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models GSA-M270 models are available for one or two stage alarm systems. The single stage double action GSA-M278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the GSA-M270 discourages tampering. Intelligent device with integral microprocessor All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. ADA Compliant Meets ADA requirements for manual pull stations. Electronic Addressing with Non-volatile memory Permanently stores programmable address, serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120 °F (49 00) Page lof4 DATA SHEET K850010279 Not to be used for installation purposes. Issue 1.1 Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or "Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonatfty Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop controller when the station's pull lever is operated. The alarm con- dition is latched at the station. Compatibility Signature Series manual stations are compatible only with Kidde's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The GSA-M270 series are opened with a tool; the GSA-M278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. is Wiring Notes L\ Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAP VIEW — of 278 tj (=) o 0 1B2 I 87 Red LED Green LED . . . (Alarm/Active) 0 TB) 432 - 5 DATA IN C") > I I DATA OUT (c) 1 DATA IN(-) > BDATAOUT( - ) From Signature Controler to Next Device or Previous Device A Figure 4. Single Stage Systems 0 REAR VIEW of 270P270P8 5 . 0 Red LED ___________ Green LED tNx'rna)) (Alsrrnf Active) - ___________ TB) _______ ___ o 0 DATA IN (C)> DATA OUT DATA IN(-) > IDATAOUt(-) J From Signature Controller I to Next Device or Previous Device A Figure 5. Two Stage Systems S Page 2 of 4 DATA SHEET k85001-0279 Not to be used for installation purposes Issue 1.1 Key-Latch Compatible Electrical Box Cover Release Rat Back Plate Toggle Switch oOfl'. s Rod W%) OPEN Figure 1. GSA-M278 installation - - - Cover Release Figure 2. GSA-M270 installation Compatible Electrical Box Cover 4 Release Screw >i Back LI f Plate Toggle F'. Switch 0 Glass Rod ZA Release Lever IS Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 2½ inch (64 mm) deep 1-gang boxes. Two stage presignal (270P) models require 11/2 inch (38 mm) deep 4-inch square boxes with i-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-0-13; in Canada, use Iberville Model Cl 52-0-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Figure 3. GSA-M270P installation Page 3 of 4 DATA SHEET K85001-0279 Not to be used for installation purposes Issue 1 .1 Specifications fII,s,. M.—h— fQAMO7fl IAPJI07fl0 1ARA070 ::~ Description Single Action Single Action -Two DoubleAction - One Stage Stage (Presignal) - One Stage Addressing Uses 1 Module I Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250lJA Standby = 396lJA Standby = 250jjA Activated = 400lJA Activated = 680pA Activated = 400A Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Càde Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes w hen in alarm Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM, FM J ''K idde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Gamer brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. Ordering Information Ship Catalog Wt. lbs Number Description (kg) GSA-M270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed GSA-M270P Two Stage (Presignal) Fire Alarm Station, English Markings 1 (0.5) - ULIULC Listed GSA-M278 Double Action (One Stage) Fire Alarm Station, English Markings - ULIULC Listed Accessories 270-GLR 20 Glass Rods - for GSA-M270 series (USA ONLY) 276-GLR 20 Glass Rods - for GSA-M278 series Page 4of4 DATA SHEET K85001-0279 Not to be used for installation purposes Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE _____ LISTING No. 7150-1483:0139 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GSA-M270 and GSA-M270P and GSA-M278 non-coded, intelligent manual pull stations. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Edwards, Edwards Systems Technology (EST), model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. These manual pull boxes meet* the requirements of UL Standard 38, 1999 Edition and . California amendments. NOTE: FORMERLY: 7150-1388:194 XLF: 7150-1657:0129 Corrected 03-17-15 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division KTD ' Intelligent Input-Output K*Idde 1 7 7 't I 9 0 N I C Technology that saves lives Input Modules 41*11~ GSA-CT1, GSA-CT1 HT, GSA-CT2, GSA-MCT2 MEA I 73083: GSA-CTI/2 GSA-MCT2 S3424 Overview Standard Features The GSA-Oil Single Input Module, GSA-Oil Hi High Temperature Single Input Module and GSA-0T2/GSA-M0T2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (l DC). The actual function of these modules is determined by the "personality code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configuration. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes The signal and decides whether or not to input an alarm. The GSA-CT1, GSA-CT1 HT and GSA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The GSA-Oil Hi module operates at an expanded temperature range of 32 OF to 158°F (0 °O to 70 00) for those applications requiring more extreme environmental temperature variation. The GSA-MCT2 is part of the UIO family of plug-'n Signature Series modules. It functions identically to the GSA-0T2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assembies may be mounted in Kidde enclosures. Multiple applications Including Alarm, Alarm with delayed latching (retard) for waterfiow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the module through the loop controller. GSA-CTI HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UlO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop controller, a PC, or the Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET K85001-0241 Not to be used for installation purposes Issue 1.1 Compatible electrical box Wall plate, white (1-gang) Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the Signature Program/Service Tool. Kidde recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is determined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the GSA-CT1. Two personality codes can be assigned to the GSA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on GSA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Personality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. DATA SHEET K85001-0241 Not to be used for installation purposes Issue 1.1 Signature Series Overview The Signature Series intelligent analog-addressable system .from Kidde Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user- friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits - Self- diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation .GSA-CTI, GSA-CT1HT and GSA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm') wire size. Status LED viewing ports J 1 GSA-MCT2: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the GSA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see .wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 Typical N.O. Initiating Device LLStyle Red I (Alarm/ DATA IN (+) 1 DATA IN(-) From Signots or Previous Device INPUT 2 S S S UL/ULC Listed 471<51 EOL Green LED (Normal) DATA OUT DATA OUT l-)} • To Next Device UI/ULC used 47KW EOL ULIULC Listed 47" EOL - - - uloyotssnies nnothsnbtotd m14NoCntflsnsq4inetO, , \I Gr— LED 04-1 L__If :: ((J INst ,nettion ipst settings 1toqtitsd to, 420. GSA-MCT2 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16(1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per CircLit For Design Reference: Wire Size I Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) 4,000 ft(1 219 m) I GSA-Cu, GSA-CT1 HT Typical N.O. Initiating Device fi I INPUT 1 1 .CX UL/ULC Listed Style B (Class B) 471<0 EOL UL/ULC Listed 47KDEOL Green LED (Normal) Red LED (Alarm/Active) FBi DATA IN DATA IN(-) fl From Signature Controller or Previous Device GSA- CT2 rypitel so 545o74,g I I NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2 ) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @ 350 pA The GSA-U106R and the GSA-U102R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of Kidde's Signature Series intelligent processing and control platform. They are compatible with VM, and VS Series control panels. L] Page 3of4 DATA SHEET K850010241 Not to be used for installation purposes. Issue 1.1 Specifications Catalog Number GSA-CTIHT I GSA-CT1 GSA-CT2 GSA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Standby = 396pA; Activated = 400pA Activated = 680tJA Operating Voltage 15.2 to 19.95 Vdc (19 Vdcnorrunal) Construction High Impact Engineering Polymer -- Mounting North American 21/2 inch (64 mm) deep one-gang box- U102RI6R/6 es and 11/2 inch (38 mm) deep 4 inch square boxes Motherboard with one-gang covers and GSA-MP mounting plates Operating Environment 32°F to 158°F (0°C to 70°C) o 0 0 to 9 Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Both LEDs - Glow steady when in alarm Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM OPKidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.tire@carrier.com Website: kidde-esfire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. Ordering Information Catalog Ship Wt. Number Description lbs (kg) GSA-CT1 Single Input Module - UL/ULC Listed 0.4 (0.15) GSA-CT1HT Single Input Module High Teperature Operation UL/ULC Listed 0.4 (0.15) GSA-CT2 Dual Input Module - ULJULC Listed 0.4(0.15) GSA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box- Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) GSA-UI02R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions GSA-UI06R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions GSA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC A Multifunction Fire Cabinet - Red, supports Signature Module 7.0(3.1) - Mounting Plates GSA-MB4 Transponder Mounting Bracket (allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) 0 Page 4of4 DATA SHEET K85001-0241 Not to be used for installation purposes Issue 1.1 1~ A160 Pr K1*dde Technology that saves lives Control Relay Modules GSA-CR, GSA-MCR, GSA-CRR, GSA-MCRR Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The GSA-CR/MCR Control Relay Module provides a Form C" dry relay contact to control external appliances such as door closers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board microprocessor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the GSA-CR/MCR relay activates the normally open or normally-closed contact. The GSA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of GSA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the GSA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (GSA-CR and GSA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (GSA-MCR and GSA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that claracterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. KDDF 'ata D Intelligent Input/Output orripatible VS&VM control systems .. MEA 73001483 GSA CR 0115 GSA-MCR S3424 Standard Features Provides one no/nc contact (GSA-CR/MCR) Form "C" dry relay contact can be used to control external appliances such as door closers, fans, dampers etc. Allows group operation of sounder bases The GSA-CRR/MCRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a si.igle module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop controller, a PC, or the SR3A-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Page lof6 DATA SHEET K850010239 Not to be used for installation purposes. Issue 1.1 Installation Application GSA-CR and GSA-CRR: modules mount to North American 21/2 .inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) Status LED viewing ports II • ' II GSA-MCR and GSA-MCRR: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive I screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. _ UIO Motherboard -------------- - I I Plug-in (U10) Module --E-- The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (GSA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Vac (or 0.25A © 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configuration is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (GSA-CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility These modules are part of Kidde's Signature Series intelligent processing and control platform. They are compatible with VM, and VS Series control panels. Warnings & Cautions This module will not operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other pertinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Kidde recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Page 2 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes Issue 1.1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), #14 AWG (1 .50mm2) and #12 AWG 2.5mm- wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease ct installat:cn. See Signature Loo3 Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed I f DATA IN (+) 1 DATA IN(-) From Signature FAI GSA-CR Control Relay Normally Open Common Normally Closed 1234 Data In + Data Out Green LED (Normal) Red LED (Active) Green LED (Normal) Notes A OUT (+) A ext Device \ Refeto Signatve Loop Conoller Installation Sheet for wiring specificatiois. NFF`A 72 requires tiat the GSA-CR/GS-MCR be instaied in the same room as the cevice it is ccntrolliig. This requirement may not apply in all markets. Check wiTh your local AHJ for details. The GSA-1J106R ard the GSA-UI02R do not come with TB1 4. 4\ The 3SA-U106 does not come with TB3 through 1B13. L\ Supervised and power-limited. If the source is ronpower-lim!ted, maintain a space of 1/4 inch from power-limited wiring or use FFL, FPLP, FPLR, cr an equivalent in accordance With the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mu. 418 (0.75mm9 No connecono required for MCR. Other mocules mod require cornecons. No connections required for MCR. Otier modules may require connections. GSA-MCR Control Relay S Page 3 of 6 DATA SHEET k85001-0239 Not to be used fcr tnstallat on purposes Issue 1.1 GSA-MCRR Schematic Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. AB4G AB4G AB4G Audible Bose Audible Base Audible Base Listed 24 VDC Nominal Powei Suppl Signature Controller sounder base GSA-MCRR GSA-CAR Schematic wer 4cm, 01.1 RlO,1v RecesseS - - WPcn ACllv3tcd 4 32 LaxxeI_ I- 0 _ 0 Audible 0 z 0 - Oases + eS eS -41 Ce us us 000 '6254A-003 I EOL Relay required for supenislan 0 . For normal operation CT' For General Fire Alarm Operation Notes Al Refer to the Signature controller installation sheet for wiring. One Pair of Wires (24 Vdc power). One Pair of Wires (Signature Data). 4\ Single Wire (24 Vdc power). The GSA-U106R and the GSA-U102R do not come with TB1 4. The GSA-0106 does not come with TB8 through T81 3. Supervised and power-limited. ZL If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG (2.5mm2 ) wire; Minimum #18 AWG (0.75mm2 ). 10 End-of-Line Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be "T-tapped." Signature — Data Data Out Circuit I + UIIUIC Listed 24Vdcpower ppl - ar suy —ar- 1234 1234 II A, A J/ jju'MCRR series motherboard oatoOut1 I II t-1I 4 Signature 4 - -EM No connections required for 1(( 'MCRR. Other modules may Circuit Dat !iIT 187 01 Data require connections U Green LED (Normal) Red LED (Active) _/' .. TOGS reg connections required for Green LED (Normal a. .. R. Other modules may Red LED lActiuel 1 2 3 4 ire connections. Optional MCRR or MCR for disabling/disconnecting No connections required for MCRR. Other an audible base modules may require connections. - Page 4 of 6 DATA SHEET K85001-0239 Not to be used for installdtion purposes Issue 1.1 Specifications Catalog Number - GSA-CR GSA-MCR GSA-CRR GSA-MCRR Description Control Relay Polarity Reversal Relay Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current f Standby = 75 pA Activated = 75 pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C, 2 Amps @24 Vdc (pilot duty), 0.5 Amps © 120 Vac and 0.25 Amps @220 Vac (220 Vac is non-UL). Not rated for capacitive loads. Mounting North American 21/2 inch Plugs into U102R, UlO6R or North American 21/2 inch 1 Plugs into U102R, U106R or (64 mm) deep i-gang boxes U106 Motherboards (64 mm) deep i-gang boxes U106 Motherboards QII.A QIIU I7dII&#IlkOC) 111111) UQQP 4 inch square boxes with 4 inch square boxes with 1-gang covers and GSkMP 1-gang covers and GSA-MP mounting plates mounting plates Construction & Finish High Impact Engineering Polymer Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controlle- Agency Listings -r UL, ULC, CSFM, MEA Ordering Information Catalog Number Description Weight - lbs Ship (kg) GSA-CR Control Relay Module (Standard Mount) 0.4 (0.15) GSA-MCR Control Relay Module (UIO Mount) 0.18(0.08) GSA-CRR Polarity Reversal Relay Module (Standard Mount) 0.4 (0.15) GSA-MCRR Polarity Reversal Relay Module (UlO Mount) 0.18(0.08) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1(0.6) 27193-16 Surface Mount Box - White, 1-gang 1(0.6) GSA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) GSA-U106R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) GSA-UIOS Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) GSA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1) GSA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-garg box) 0.4(0.15) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 5 of 6 DATA SHEET K85001-0239 Not to be used for installation purpose s Issue 1.1 [1 Signature Series Overview The Signature Series intelligent analog-addressable system from Kidde is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits - Self- diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self- checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. The information stored in device memory includes: Device serial number, address, and type Time and date of last alarm Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping —The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configuration and are indicated during device mapping. Standalone Operation - A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone (degrade) mode. If Signature loop controller CPU communications fail for more than four seconds, all devices on that circuit go into standalone mode. The circuit acts like a conventional alarm receiving circuit. Each Signature device on the circuit continues to collect and analyze information from its slave devices. When connected to a panel utilizing standalone op- eration, modules with their "personality" set as alarm devices (IDC) will alarm should their slave alarm-initiating device activate. [I OVKidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-estire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. Page 6 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1483:0115 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GSA-CC1, GSA-CC2, GSA-Cu, GSA-CT2, GSA-CR, GSA-CRR, GSA-UM, GSA-MM1, GSA-WTM, GSA-IM, GSA-MCC2, GSA-MCT2, GSA-MCR, GSA-MCRR, GSA-MAB, GSA-MCC1, GSA-MDM remote transponders; Models GSA-U106, GSA-U106R and GSA-UI02R motherboards. Models GSA-CC1S and GSA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD enclosures. Models GSA-MP1, GSA-MP2 and GSA-MP2L mounting plates. Model GSA-CR2 Control Relay Module. *CSACRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote transponders for use with separately listed compatible fire alarm control units. 10 XLF: 7300-1657:0121 *Rev. 03-29-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division AIR AND PAM SERIES You /in Control MULTI-VOLTAGE RELAY MODULES The PAM Series Relays are encapsulated multi-voltage devices with 'flying" leads that offer versatile, reliable perfor- mance in a convenient package. Several of the versions contain a red LED which indicates when the relay coil is energized. The PAM Series Relays are packaged with a self-tapping screw and a piece of double sided tape for easy installation almost anywhere. The relays are also packaged with wire-nuts to aid installation. PAM Relays are ideal for applications where remote relays are required for control or status feedback. They are suit- able for use with HVAC,Temperature Control, Fire Alarm, Security, Energy Management, Lighting Control Systems and Building Automation Systems. PRODUCT DESCRIPTION PAM-I The PAM-I Relay provides 10.0 A form "C" contacts. The relay may be energized by one of three input voltages: 24VDC, 24VAC, or I 2OVAC. The input voltages are polarity-sensitive and diode-protected. PAM-I Relays contain a red LED which indicates when the relay coil is energized. PAM-2 The PAM-2 Relay provides 7.0 A form "C" contacts. The relay may be energized by one of two input voltages: I 2VDC or 24VDC. The input voltages are polarity-sensitive and diode-protected. PAM-2 Relays contain a red LED which indicates when the relay coil is energized. PAM-4 The PAM-4 Relay provides 10.0 A form "C" contacts. The relay may be energized across a wide voltage range from 9VDC to 40VDC, making it ideal for I 2VDC and 24VDC EOL circuits. The I 5mA operating current is constant across the operating range. The input voltages are polarity-sensitive and diode-protected. PAM-SD The PAM-SD Relay provides 7.0 A form "C" contacts. The relay may be energized by an input voltage between 20VDC to 32VDC, making it ideal for 24VDC NAC circuits. The input voltages are polarity-sensitive and diode- protected. The PAM-SD provides an additional set of wires for redundant input voltage (circuit supervision pass through). cLus CSFM LISTED MEA ACCEPTED LISTED Air Products and Controls Inc. 1749 E. Highwood A Pontiac, Ml 48340 HALMA (248) 332-3900 Phone (888)332-2241 Toll free GROUP (248) 332-8807 Fax COMPANY www.ap-c.com I111(iPN1J RELAY ENERGIZED LED YE NC 10.0A CONTACTS ORG NO) lk WIRING PAM-1 RELAY ENERGIZED LED øV-) +24VDC @o.o15A GRY j1EL NC) 7.0 A +1 2VDC @ 0.01 5A RED ORG NO CONTACTS PAM-2 TO OrYELNC 10.0 A 4OVDC CONTACTS 9VDC ((+1 RED C 0.015A () EILK NOJ PAM-4 PRODUCT SPECIFICATIONS BLU C TO 32VDC (-) YEL NC 7.0 A 2OVDC (-) RG NO) CONTACTS (+1 0.0t5A () RE PAM-SD MUUtLNUMb: rAm-i rm- rAM-4 rAM-SI) COIL VOLTAGE: 24VAC/24VDC/120VPC 12VDC/24VDC I 9 to 4OVDC 20 to 32VDC POLARIZED; Yes Yes Yes Yes ENERGIZED LED INDICATOR Yes Yes No No CURRENT REQUIREMENT: 12VDC 24VDC @24VAC @120VAC 15mA 15mA 15mA 15mA 15mA 15mA 50mA 30mA CONTACT CONFIGURATION: (1) SPDT dry form C" (1) SPDT dry form 'C" (1) SPDT dry form "C" (1) SPDT dry form "C" CONTACT RATINGS: (Contact rating/ power factor) c5VDC l24VDC @120VAC 2501.JA /.35 PF 250pA / .35 PF 250pA 250pA / .35 PF 7A /.35 PF 7A /.35 PF 7A 7A / .35 PF 10A 7A/.35PF 10A 7A/.35PF WIRE LEADS; 6 "flying" leads 12/ 18AWG Wire-nuts provided 6 flying" leads 12"/18AWG Wire-nuts provided 5 flying" leads 12"!18AWG Wire-nuts provided 7 "flying" leads 12"/18AWG Wire-nuts provided AMBIENT TEMPERATURE: (@ 100% RH, condensing) 32°F to 120°F (0°C to 49°C) 32°F to 120°F (0°C to 49°C) 32°F to 120°F (0°C to 49°C) 32°F to 120°F (0°C to 49°C) CONSTRUCTION; 100% potted (sealed) with "flying" leads MOUNTING: Pre-drilled mounting screw hole and self tapping screw provided. Double sided tape provided. DIMENSIONS; H W D 1.50' (38mm) 1.50" (38mm) 1.50' (38mm) 1.50" (38mm) 1.20" (25mm) 1.00" (25mm) 1.00" (25mm) 1.00" (25mm) 0.90" (20mm) 0.90" (23mm) 0.90" (23mm) 0.80" (20mm) LISTINGS AND APPROVALS; UL*: MEA: UOXX/7.53403 UOXX/7.53403 UOXXI7.53403 UOXX/7.53403 73-92-E Vol. 21 73-92-E Vol. 21 73-92-E Vol. 21 73-92-E Vol. 21 7nnnl nnA•f ni 7nrL1 nnAlnl I 'nn n(SA'l ni 7'flfl1 flClA -1 °UOXX=Control Unit Accessories, System; /7=also Certified for Canada NOTICE: The information contained in this document is intended only as a summary and is subject to change without notice. The products described have specific instructionaltinstaltation documentation, which covers various technical, approval, code, limitation and liability information. Copies of this documentation along with any gen- eral product warning and limitation documents, which also contain important information, are provided with the product and are also available from Air Products and Controls Inc. The information contained in all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to an', implementation. For further information or assistance concerning the products, contact Air Products and Controls Inc. Air Products and Ccntrols Inc. reserves the righ: to cI- ange any and all documentation without notice. ©Air Products and Controls Inc. 2006 DS-RL-1 E060404 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America lnc.25 Corporate Dr., Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MR101/C/R *MR.i oi-SSE/C, *MR.10SSE/C/R MR-104/C, *MR104/C/R *M R-i 04-SSE/C, *MR104SSE/C/R MR-201/C, MR-201 /C/*R, *MR201 -SSE/C, *M R-201 -SSE/C/R, MR-204/C, MR204/C/*R, *MR204.SSE/C *MR204SSE/C/R PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RIC-11, RIC-2, RIC-3, RIC-4, MRRlC301/*C, *MRRlC301/C/R MRRlC305*/C, * MR-RIC-305/C/R, MRRlC401*/C, *MRRlC..401/C/R MRRlC405*/C and *MRRlC405/C/R relay modules. *Models MR-ITM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division 18 fKidde K I .,e Cal,),o I I> Strobes, Horns, Bells, Chimes Technology that saves lives Low Frequency Audible Signals Genesis G4LF Series S218 Overview G4LF Series notification appliances provide the benefits of Gen- esis life safety signals with output suitable for applications requiring low frequency audible tones. These high-performance appliances generate a crisp 520 Hz tone in the standard 3-3 temporal pat- tern. An optional setting configures the appliance for continuous audible output - a critical feature for notification appliance circuits that are coded with a CDR-3 coder module. G4LF appliances also feature field-configurable high and low dB output settings. When connected to compatible control equipment, G4LF Series audible output remains synchronized with all Genesis audible sig- nals on the same Notification Appliance Circuit, inciuding standard 3.2 kHz Genesis audible signals. Available G4LF models include audible-only appliances, as well as combination audible-visible signals. Combination appliances feature Genesis FullLight" strobe technology, which produces a smooth light distribution pattern without the spikes and voids that characterize bulky specular reflectors. This ensures the entire coverage area receives consistent illumination exceeding UL-1 971 light distribution requirements. It also results in a slim, low profile device that blends with any decor. Candela output is field configu- rable. When connected to a compatible synchronization source, Genesis appliances synchronize (strobes to UL 1971) to within 10 millisec- onds indefinitely without the need for external modules or other equipment. See the Specifications section for a list of synchroniza- tion sources. Standard Features Unique low-profile design... - Compact UL listed audible and audible-visible appliances - Ultra-slim: protrudes an inch from the mounting surface - Attractive appearance: no visible mounting screws Choice of colors and markings... - White or red housings - With or without FIRE markings Easy to install... - Room side wiring accepts #18 - #12 AWG (0.75 to 2.5 mm2) - Fits standard 4-inch square electrical boxes or standard Gensis EG413 or EG4RB surface-mount boxes Easy to configure without removing the device... - High or low dB output - Temporal or continuous audible tone - Temporal or continuous visible output - 15, 30, 75, or 110 candela intensity High performance output... - Exclusive FullLight" strobe output distribution pattern - Meets tough synchronization standards for strobes and audible signals S Page lof4 DATA SHEET K850010639 Not to be used for installation purposes, Issue 1 n 1 Q74 Ill ~jZN 1 4 %1j~7p EG4B or EG4RB Surface Mount Box Application Genesis G4LF Series appliances are UL 464-listed for low-fre- quency audible requirements. Models are also available in combi- nation with a UL 1971-listed strobe light for indoor wall-mounted public-mode notification applications. Many codes and regulations now call for low-frequency audible appliances (520 Hz) in newly constructed sleeping rooms and also require strobe lights under some of these circumstances. Consult with your Authority Having Jurisdiction for details. Combination audible-visible appliances are installed in accordance with guidelines established for visible (strobe) devices. When used with a compatible synchronization source, all Genesis xenon-based strobes - audible units, and combination appli- ances - maintain fully synchronization indefinitely. This exceeds the UL synchronization requirements of 10 milliseconds over a two-hour period. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Kidde recommends that these devices always be installed in ac- cordance with the latest recognized edition of national and local codes. Refer to the appropriate codes and standards for mounting height information. For sleeping rooms, most codes and standards require 75 dBA fast at the pillow. For non-sleeping rooms, the suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maxi- mum sound level having a duration of at least 60 seconds, which- ever is greater. This is measured 5 feet (1.5 m) above the floor. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Visible Signal Application For sleeping rooms covered by NFPA, a strobe light is typically re- quired within 16 feet of the pillow. If the strobe light is wall-mount- ed and at or farther than 24 inches (610 mm) from the ceiling, it should be 110 cd or greater. If the strobe light is ceiling-mounted or wall-mounted closer than 24 inches (610 mm) to the ceiling, it must be 177 cd or greater. Installation Genesis G4LF Series appliances mount to a standard 4 inch (102 mm) square electrical box using the provided mounting spacer or directly to a Genesis G4 surface mount box. All Genesis appliances have two tabs at the top of the signal. Unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Typical Wiring Room-side field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Audible appliances, strobes, and combination audible-visual appliances are interconnected with a single pair of wires as shown. From NAC output To next,device or EOL From NAC output m IJI I!! Audible Signal Application Genesis low-frequency audible output features a code-compliant 520 Hz signal. Audible signals may be configured for either coded .or non-coded signal circuits. They can also be set for low dB out- put with a jumper cut that reduces audible output by about 5 dB. Audible-only models may be ceiling-mounted or wall-mounted. Note: Polarity is shown in the active condition. Page 2of4 DATA SHEET K850010639 Not to be used for installation purposes. Issue I JP3 Audible dB Output: JP3 - - - cut for low. JP2 Audible I pattern: cut for steady. JP1 Strobe pattern: Cut :2 for temporal (private i mode only). Candela switch and indicator Genesis G41LF Series strobe lights may be set for 15, 30, 75, or 110 candela output. The output setting is changec by simply opening the device and sliding the switch to the desired setting. The appliance does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Nominal Sound Level Output UL(dBA) UL464:Sound Signal and voltage Low High level Output at Temporal 16 VDC 72.4 76.0 iC ft. (3.05 m) measured in a 24 VDC 72.3 75.7 reverberant room. 33 VDC I 73.3 I 75.4 Continuous 16 VDC I 75.7 I 79.8 24 VDC 76.1 78.6 33 VDC 75.4 78.8 Field Configuration Genesis G4LF Series audible appliances are factory set to oper- ate in a Temporal 3 (three-pulse) pattern. Units may be configured for use with coded systems by cutting jumper JP2 on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required to maintain G4LF strobe light synchronization when connected to a coded system. Audible signals and combination audible-visible appliances are factory set for high dB output. Low dB output may be selected by cutting jumper JP3 on the circuit board. This reduces the output by about 5 dB. Genesis G4LF Series strobe lights are shipped from the fac- tory ready for use as UL 1971 compliant signals foc public mode operation. These signals may be configured for temporal flash by cutting jumper JP1 on the circuit board. This battery-saving feature may be used for private mode signaling only. Light Output Per cent of UL rating versus angle Candela H Spec. -%OtCandelaeSpec. So .50 Jç,\ S.. \\\ J : t ,'1't/t ///• \o , 't,' a 70 45 Mlnsnr UL recured candela light output Current Draw Audible-Visible Appliances Operating horn-strobe current in RMS (mA) with audible set to standard (high) output Strobe 15 30 I 75 110 output (Cd) I Temporal 16 VDC 219 266 381 437 16 VFWR 308 362 510 579 24 VDC 151 176 243 278 24 VFWR 228 258 349 395 33 VDC 112 132 177 1 199 33 VFWR 186 208 1 267 1 291 Continuous 16 VDC 221 258 371 433 16 VFWR 305 358 514 576 24 VDC 147 171 239 274 24 VFWR 211 247 335 377 33 VDC 110 179 175 196 33 VFWR 178 199 257 282 VDC = Volts direct current, regulated and filtered VFWR = Volts full wave rectified Operating Curreni RMS (mA) Audible appliance only Signal and voltage ' Low Hiah Temporal 1 16 VDC 86 166 24 VDC 43 112 33 VDC 36 87 16 VFWR 97 215 24 VFWR 78 159 33 VFWR 76 140 Continuous 16 VDC 36 160 24 VDC 45 109 33 VDC 36 86 16 VFWR 92 212 24 VFWR 80 168 1 33 VFWR 77 141 VDC = Volts direct current, regulated and filtered VFWR = Volts full wave rectified Page 3 of 4 DATA SHEET K85001-0639 Not to be Leed for installation purposes Issue 1 fr&Kldde re~~~ Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4o14 Specifications Genesis G4LF Audible and Visible Signals Operating voltage 24 VDC or 24 VF\NR [1] Housing Red or white textured UV stabilized, color impregnated engineered plastic. Dimensions Height: 6.5" (165 mm). Width: 5" (127 mm). Depth to wall: 1" (25 mm). Mounting Flush: North-American 4" square box, 2 1/8(54 mm) deep. Requires (indoor wall mount supplied spacer. only) Surface: model E348 (white) or EG4RB (red) surface mount box. Synchronization FACPs: VM and VS Series life safety systems, FX Series fire alarm control Sources panels. Moduels: GSA-CC1S, GSA-MCC1S, SIGA-CC2A, GSA-MCC2A, EG1M-RM. Power supplies: MIRBPS6A, MIRBPS1OA, APS6A, APS10A. Wire Size 12 to 18 AWG (0.75 to 2.50 mm2). Operating 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity, environment noncondensing. Audible Signal Audible pulse rate Temporal rate with compatible synchronization source: indefinitely within 10 milliseconds. Temporal audible ½ sec ON, Y2 sec OFF, ½ sec ON, Y2 sec OFF, ½ sec ON, 11/2 sec OFF, pattern then repeat cycle. Visible Signal Strobe Output Rating UL 1971: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe Operating 16 - 33 Vdc Regulated, 16-33 V Full wave rectified (UL Voltage Voltage Designations "Regulated 24" and '24 fwr") Strobe Flash Rate One flash per second. One flash per second (fps) within 10 milliseconds over a 2 hour time Strobe Flash period on a common circuit. Synchronization source required to comply Synchronization with UL 1971 synchronization standard. Temporal setting (private mode only): synchronized to temporal output on the same circuit. Strobe Lens Material Polycarbonate [1] This device was tested to the Regulated 24 DC/F\NR operating voltage limits of 16 V and 33 V Do not apply 80% and 110% of these values for system operation. Ordering Information I Audible Visible Ship Wt. Model Housing Marking Signal Signal lbs (kg) Fire Alarm Appliances (520 Hz screen printed on housing) G4LFWN-HVM White None Selectable Low 15, 30, 75, Frequency or 110 cd. (520 Hz) with selectable High/LowdB Audible output. only. FIRE 1.5 lbs. (0.68 kg) G4LFWF-HVM White FIRE G4LFRN-HVM Red None G4LFRF-HVM Red FIRE G4LFWN-H White None G4LFWF-H ] White FIRE G4LFRN-H Red I None G4LFRF-H Red Accessories GSA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) GSA-MCC1S Synchronization Output Module (Plug-in UlO) 0.18 (0.08) SlGA-CC2A Dual Input Signal Module with Class A Operation (2-gang) 0.5 (0.23) GSA-MCC2A Dual Input Signal Module with Class A Operation (Plug-in UIO) 0.18 (0.08) EC413 Surface mount box, white 0.7 (0.32) EG4RB Surface mount box, red 0.7 (0.32) DATA SHEET K85001-0639 Not to be used for installation purposes Issue I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1657:0320 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models G4LFWN-H, G4LFWF-H, G4LFRN-H and G4LFRF-H low frequency electronic horn for sleeping areas. The suffix R refers to red and W refers to white housing the suffix F refers to the word FIRE silkscreened on housing; N indicates no marking on housing. Intended for indoor use and mounted on a wall. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as a horn when used with separately listed electrically compatible fire alarm control units. For indoor use only on ceiling or wall. These units can generate a low frecuency alarm signal for sleeping areas in accordance with NFPA 72. Refer to Iiste&s Installation Instructions Manual for details. 03-11-l4gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 3), 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division . orKidde ii Strobes, Horns, Sells, Chimes Technology that saves lives Genesis LED EGG Series Ceiling Mount Notification Devices Overview Genesis LED EGO Series horns and LED strobes feature a sleek low profile design and energy-efficient technology that makes them less expensive to install and operate by reducing overhead High performance LEDs require fewer power supplies, backup power, and batteries. These new appliances are designed with, energy-efficiency, and life safety in mind. Genesis LED EGO Series uses high efficiency optics, combined with patented electronics, to deliver a highly controlled and efficiently focused light distribution pattern in exchange for lower current requirements. Strobes feature field-selectable 15, 30,75, or 115 Cd light output. Compared with Xenon-type strobes, Genesis LED EGO Sees appliances need fewer power supplies and often smaller wire gauge, which lightens conduft requirements. They are also backwards compatible with legacy strobes, so there's no need to replace all your existing devices to upgrade to new LED technology. In fact, EGO strobes can be mixed on the same circuit and used in the same field of view as Xenon-based strobes. This makes Genesis LED EGO Series ideal for new installations and retrofits alike. Field-configurable sound output levels provide the flexibility modern life safety projects demand, while the Genesis LED control protocol keeps multiple strobes on compatible NAO circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where EGO Series appliances shine. The universal room side wiring plate allows for pre-installation and electrical wiring as well as checking continuity with the included diagnostics check bar. EGO Series devices can then be easily snapped into place with the confidence of knowing the wiring is correct. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Page 1 of 6 .T ki S..... S.... ...... t. IL. I •••••S• _____ w :•:•:•:•:•:• Standard Features 7125-16570510 71,c_l 657nc1 c High Performance LED Strobe Technology ......-- - - Ultra low device current consumption allows: FM - More devices per circuit - Ability to use lower gauge wire APPROVED - Longer wire runs - Fewer booster power supplies - High efficiency optics - Selectable 15, 30, 75, or 115 cd light output - LED devices may be mixed with legacy Xenon strobes Efficient Audible Output - Selectable high or low dB horn output - Selectable temporal or steady horn output - Improved audio frequency range for better wall penetration Low-profile Design - Ultra-slim.., protrudes about 1.5" from the mounting surface - Attractive appearance... no visible mounting screws Multiple Marking Options - Order Red or White with or without FIRE markings - Change markings at any time with replaceable quick-swap covers Easy to Install - Pre-install and pre-wire with convenient universal room side wiring plate - Check electrical continuity on room side wiring plate with included diagnostics check bar - Diagnostics port streamlines device circuit testing - Fits 1-gang, 2-gang, 4-inch octagon, and 4-inch square electrical boxes - Optional red and white trim plates available - Slide switches for field configuration - 12 to 18 AWG in-out screw terminals for quick wiring DATA SFIEET K850011021 Not to be useO tor ,nstall.ttiop purposus Issue 1.2 Genesis LED EGO Series horns, strobes, and horn-strobes mount to any standard one-gang, two-gang, 4-inch octagon, and 4-inch square electrical box. Matching optional EGOT trim rings are available to cover oversized openings. Optional color matched double-gang surface boxes are also available. Genesis LED EGO series are listed to be both wall mounted or ceiling mounted. Application Strobes Genesis EGO Series strobes are UL 1971 -listed for use indoors as ceiling-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87 dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act. Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. See the specifications table for a list of compatible sources. Horns Genesis horn output reaches as high as 92 dBA and features an improved audio frequency range compared with other Genesis horns. This results in excellent sound penetration through walls and a clear warning of danger. Horn only models may be configured for either coded or non-coded notification appliance circuits. They can also be set for high or low dBA output. This setting reduces horn output by about 6 dBA. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dBA above the average ambient sound level, or 5 dBA above the maximum sound level having a duration of at least 60 seconds, whichever is greater. These values are measured at five feet (1.5 m) above the floor. The average ambient sound level is A-weighted, fast response sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dBA reduction of the received sound pressure level. The actual effect depends on the acoustic environment in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation Genesis EGO horns and strobes mount to the required GP10 room side wiring plate. The GP10 mounting plate is included with the device for convenient pre-installing and pre-wiring. The device can be removed easily from the room side wiring plate by pushing up with a screwdriver. The cover can also be removed from the device easily with a screwdriver to access the light and sound output settings and a diagnostics test port for voltage testing. Removing cover Removing Device Page 2 of 6 (3 I Electrical Box Trim Plate (optional) Wiring plate (required, included with device) Machine screw (2, supplied with wiring plate) EGG signaling appliance Wiring Horn/strobe circuit in (signal polarity shown in the active condition) + Horn/strobe - circuit out Shorting Clip DATA SHEET K85001-1021 Not to be used for installation purposes. Issue 1.2 Dimensions EGC Notification Appliances 1.82" (4.62 cm) 6.8' (17.27 cm) 0.3" (0.76 cm) Diagnostics [I Constant, low dB Constant, high dB T3 temporal, low dB T3 temporal, high dB 115 candela 75 candela 30 candela (8)15 candela 10.6" Test points indicated . above are used to validate the Notification Appliance Circuit and verify device function. Horn-Strobes Strobe setting Sound setting 16to33VDC 16to33VFWR 15, 30, C-Low, T-Low 50 mA 60 mA 75,115 C-Hih,T-Hih 60 mA 75 mA Field Configuration Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. By sliding the tone selector switch, horn only models may be configured for constant horn output that can be coded at precise intervals by KIDDE control panels and control modules. Note: Temporal 3 coding is the required output for fire notification devices per NEPA 72. Any device coding other than temporal 3 is at the discretion and approval of the local authority having jurisdiction (AHJ). Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by sliding the tone selector switch. This reduces the output by about 6 dBA. Genesis LED clear strobes and horn-strobes may be set for 15, 30, 75, or 115 candela output. The output setting is changed by simply removing the cover and sliding the candela switch to the desired setting. The device does not have to be removed from the wall to change the output setting. The setting remains visible through a small window on the device after the cover is closed. EGCT Trim Plate (optional) Light and Sound Output Settings Operating current Horns Strobes Sound 16t033 16 to 33 Strobe setting VDC VFWR setting C-Low, T-Low 20 mA 25 mA 15,30, 75,115 -High, T-High 30 mA 40 mA 16t033 16t033 VDC VFWR 35 mA 45 mA DATA SHEET K85001-1021 Page 3 of 6 Not to be used for installation purposes Issue 1.2 Sound Output Light Distribu:ion Horn & Horn-Strobe Horizontal Left 0 Horizontal Right Reverberant Anechoic 15 10 5 10 15 30 Sound setting 25 25(111464) (CAN/ULC - 5925) 35 35 \ f / /t-•-.-.0 C-Low, 1-Low 80 dBA 86 dBA 40 45 45 G--High, T-High 86 dBA 92 dBA 50\\<\ o 55 60 6/5 7 70 75 75 65 Sound pattern - Horn Models (ULC) 8c :: , L Axis 85 Angle(°) Output (dBA) 90 i.j::- >' - 1 90 :zta1 Val 125 and 50 91.7 80 4 115 and 55 93.3 85 75 70 v 70 6 60 /fli 60 55 55 Sound pattern - Horn-Strobe Models (ULC) 5 0 - ,i- / f \\ \ /so 45 \/'45 Axis Angle (°) Output (dBA) 0 5/ /' 7--t- \ '_>5 40 Horizontal 145 and 35 93.0 0 1 2530 2) 15 I 20 I55 and ,i I2U. 10 5 10 Vertical Bottom 135 and 35 92.0 Vertical 155 and 25 85.4 Vi-as-red U_Mnumum Specifications Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or TC3 temporal Light output 15, 30, 75, or 115 candea Strobe flash rate 1 fps (flash per second) approx. Synchronization 20 C) max. between any two devices. To determiie allovel wire resistance, refer to these specifications, and the specifications for the sync-iron--el:: signal source. Synchronization Sources Kidde CC Series Signal Modules, Booster and Auxiliary Power Supplies, Intelligent and Conventional Control Panels Wire size 12 to 18 AWG (0.75 to 2.50 mm2) Mounting Wall or Ceiling mount Dimensions (0 x D) 6.8 x 1.82 in. (17.27 x 4.62 cm) Strobe-to-box center offset -1.70 inches (-4.32 cm) Compatible electrical boxes [1] 1-gang, 2-gang, 4-inch octagon, 4-inch square Trim plates EGCTR, EGCTW 10.6 x 0.3 in. (26.92 x 0.76 cm) Operating environment Temperature Relative humidity 32 to 122°F (0 to 50°C) 0 to 93% noncondensing Storage Temperature -40 to 158 F (-40 to 70 C lii Electrical boxes must beat least 1-1/2 in. (3.81 cm) deep. Page 4of6 DATA SHEET K850011021 No: to be used for installation purposes, Issue 1.2 Ordering Information Q EGCARF-CVR Red FIRE EGCARF Red FIRE EGCAWA-CVR White ALERT EGCAWF-CVR White FIRE Horns EGCAWF White FIRE Horn Covers - EGCAWN-CVR White None EGCVRF Red FIRE EGCVRF-CVR Red FIRE EGCVRN Red None EGCVWA-CVR White ALERT EGCV\NF White FIRE EGCVWF-cVR White FIRE Strobes -- Strobe EGCVWN White None Covers EGCVWN-CVR White None EGCAVRF Red FIRE EGCAVRF-CVR Red FIRE EGCAVRN Red None EGCAVWA CVR White ALERT EGCAWVF White FIRE " EGCA\ANF-CVR White FIRE Horn-strobes Horn-strobe EGCAW/N White None Covers EGCAVWN-CVR White None Accessories Room Side Wring GP10 * EGCTR Trim plate, EGG Series, EGCTW Trim plate, EGC Series, included with device) red white 27193-21 Two-gang surface 27193-26 Two-gang surface mount box, red mount box, white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers Genesis series Genesis Series EGC = ceiling mount appliances EGC = Ceiling mount appliances = [ I r Housing Color Housing Color R Red R=Red W = White W = White Cover E G CAV RF Housing Marking EG CAV R F- CVR Designation F = FIRE T Housing Marking T N=None N = None Functions Functions F = FIRE A = Horn only A = Horn only A = ALERT V = Strobe only V = Strobe only AV = Horn-Strobe AV = Horn-Strobe Page 5 of 6 DATA SHEET K85001-1021 Not to be used for installation purposes. Issue 1.2 C J~'Kidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. S S Page 6 of 6 DATA SHEET k85001-1021 Not to be urd for installat on aurposes Issue 1.2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0510 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Edwards Models GCV, GCVWF, GCVWF-SP, GCVRF-SP, GCVWF-FR, GCVRF-FR, GCVRF, GCVWN, GCVRN, *GCV* *GCV*F *GCV*FFR *GCv*F.Sp and *GCF*N indoor wall/ceiling mounted strobes. Edwards Models GCVWA and *GCV*A indoor wall mounted strobes. Kidde Models EGCV, EGCVWF, EGCVRF, EGCVRN, EGCVWN, *EGCV* *EGCV*F and *EGCV*N indoor wall/ceiling mounted strobes. *For models with an Asterisk *: The * can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color option other than red or white. The basic differences between each model are as follows: - GCV base model for strobe . - Suffix WF white enclosure with FIRE marking - Suffix RF red enclosure with FIRE marking - Suffix WN white enclosure with no marking - Suffix RN red enclosure with no marking - Suffix FR marking is FEU - Suffix SP marking is FUEGO - Suffix WA white enclosure with ALERT marking - Prefix E designates brand as KIDDE instead of EDWARDS Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 Vdc/fwr Candela 15cd, 30cd, 75cd, 115cd selectable INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. *Revision 05-12-20 V\MN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires August 29, 2020 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7125-1657:0510 Page 2 of 2 Models beginning with E are marked Kidde. APPROVAL: Listed as a strobe for the hearing impaired when used wit separately listed electrically compatible fire alarm control units. The lights are only considered synchronized when used in conjunction with Listed Model G1M-RM (CSFM listing No. 7300-1657:0201) or Model SIGA-CC1S (CSFM listing No. 7300-1657:0121). Refer to listee's Installation Instruction Manual for details. *Revisicn 05-12-20 Wf'N This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims- This listing is not an endorsement or recommendation of the item listed. This listing should nct be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, insta lation instructions and/or other Date Issued: July 01, 2019 Listing Expires August 29, 2020 0 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0202 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models "EST" G1-HV15, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -HOV75, -HOV110, GlF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, Gi R-HDV1575, G1F-HDV1575, and G1RF-HDV1575 horn/strobes with or without suffixes -Rand -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33Vdc/Vfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, 01 R-HDV1 575, G1F-HDV1575, G1RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 01 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, 01 R-HDV1575, 01 F-HDV1 575, G1 RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GCHDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL SFIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0515 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Edwards Models GCA, GCARF, GCARF-FR, GCARF-SP, GCARN, GCAWF GCAWF-FR, GCAWF-SP, GCAWN, *GCA*, *GCA*F *GCA*FSP *GCA*FFR and *GCA*N Synchronizable Wall/Ceiling Mounted Horns for indoor use. KIDDE Models EGCA, EGCARF, EGCAWF, *EGCA*, and *EGCA*F Syncronizable Wall/Ceiling Mounted Horns for indoor use. Edwards Models GCAV, GCAVRF, GCAVRF-FR, GCAVRF-SP, GCAVRN, GCAVWF, GCAVWF-FR, GCAVWF-SP, GCAVWN *GCAV* *GCAV*F, *GCA\/*FSP GCAV*FFR, and *GCAV*N Wall/Ceiling Mounted Horn/Strobes for indoor use. KIDDE Models EGCAV, EGCAVRF, EGCAVRN. EGCAVWF, EGCAVWN, *EGCAV* *EGCAV*F, and *EGCAV*N Wall/Ceiling Mounted Hom/Strobes for indoor use. Edwards Models GCTR, *G,ST* and GCTW Trim Plates. KIDDE Models EGCTR, *EGCT* and EGCTW Trim Plates. Model GP maybe followed by a numeric value to designate the quantity per package Room Side Wring Plate. *For models with an Asterisk *: The * can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color option other than red or wh te. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 Vdc/fwr Candela 15 cd. 30cd, 75, 115 cd selectable 82 dB at 10 feet INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicale codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *Revision 05-12-20 V\MN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data bul does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7125-1657:0515 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. Models beginning with E are marked for Kidde. APPROVAL: Listed as horn or horn/strobe when used with a separately listed compatible fire alarm control unit. Units are suitable for indoor dry locations only. These units can generate a distinctive 3-Pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72. Listed as a strobe or horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. The lights are only considered synchronized when used in conjunction with Listed Model G1M-RM (CSFM listing No. 7300-1657:0201) or Model SlGA-CC1S (CSFM listing No. 7300-1657:0121). Refer to listees Installation Instruction Manual for details. *Revision 05-12-20 VtMN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Is Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division 4'vK *Idde Pr KIDD Catalo.j P Strobes, Horns, Bells, Chimes n Technology that saves lives Wall Mount Signaling Appliances Genesis LED EG4 Series • - ....••S. ••s.... . - -. - . ...•••I•.••.•.... . . -. •.•.•. . - -. . . ...•.S. ••••••• .•.•.I• •.•.*.•. • •••._a_• S • • . Overview Genesis LED EG4 Series horns and LED strobes feature a sleek low profile design and energy-efficient technology that makes them less expensive to install and operate by reducing overhead. High performance LEDs require fewer power supplies, backup power, and batteries. These new appliances are designed with, energy-efficiency, and life safety in mind. Genesis LED EG4 Series uses high efficiency optics, combined with patented electronics, to deliver a highly controlled and efficiently focused light distribution pattern in exchange for lower current requirements. Strobes feature field-selectable 15, 30, 75, or 110 cd light output. Compared with Xenon-type strobes, Genesis LED EG4 Series appliances need fewer power supplies and often smaller wire gauge, which lightens conduit requirements. They are also backwards compatible with legacy strobes, so there's no need to replace all your existing devices to upgrade to new LED technology. In fact, EG4 strobes can be mixed on the same circuit and used in the same field of view as Xenon-based strobes. This makes Genesis LED EG4 Series ideal for new installations and retrofits alike. Field-configurable sound output levels provide the flexibility modern life safety projects demand, while the Genesis LED control protocol keeps multiple strobes on compatible NAC circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where EG4 Series appliances shine. The universal room side wiring plate allows for pre-installation and electrical wiring as well as checking continuity with the included diagnostics check bar. EG4 Series devices can then be easily snapped into place with the confidence of knowing the wiring is correct. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Standard Features High Performance LED Strobe Technology - Ultra low device current consumption allows: - More devices per circuit - Ability to use lower gauge wire - Longer wire runs - Fewer booster power supplies - High efficiency optics - Selectable 15, 30, 75, or 110 cd light output - LED devices may be mixed with legacy Xenon strobes Efficient Audible Output - Selectable high or low dB horn output - Selectable temporal or steady horn output - Improved audio frequency range for better wall penetration Low-profile Design - Ultra-si m... protrudes about 1.5" from the mounting surface - Attractive appearance... no visible mounting screws Multiple Marking Options - Order in red or white with or without FIRE markings - Change markings at any time with replaceable quick-swap covers Easy to Install - Pre-install and pre-wire with convenient universal room side wiring plate - Check electrical continuity on room side wiring plate with included diagnostics check bar - Diagnostics port streamlines device circuit testing - Fits 1-gang, 2-gang, 3.5-inch octagon, and 4-inch square electrical boxes - Optional red and white trim plates available - Slide switches for field configuration - 12 to 18 AWG in-out screw terminals for quick wiring Page lof6 DATA SHEET K85001.0668 Not to be used for installation purposes. Issue 1.3 One-gang Electrical Box Mounting Plate Machine Screw To Signaling Ap lia rw il1P!, AO 0 Shorting Fi Ie Optional Trim Plate Using a trim plate is optional. Two-gang Electrical Box 3.5-inch Octagon Electrical Box [1 Application Strobes Genesis EG4 Series strobes are UL 1971 -listed for use indoors as wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87 dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act. Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. See the specifications table for a list of compatible sources. Horns Genesis horn output reaches as high as 92 dBA and features an improved audio frequency range compared with other Genesis horns. This results in excellent sound penetration through walls and a clear warning of danger. Horn only models may be configured for either coded or non-coded notification appliance circuits. They can also be set for high or low dBA output. This setting reduces horn output by about 6 dBA. Horn-only models may be ceiling-mounted or wall-mounted. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dBA above the average ambient sound level, or 5 dBA above the maximum sound level having a duration of at least 60 seconds, whichever is greater. These values are measured at five feet (1.5 m) above the floor. The average ambient sound level is A-weighted, fast response sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dBA reduction of the received sound pressure level. The actual effect depends on the acoustic environment in the space. A 3 dBA difference represents a bares' noticeable change in volume. Installation Genesis EG4 horns and strobes mount to the required GP10 room side wiring plate. The GP1 0 mounting plate is included with the device for convenient pre-installing and pre-wiring. The device can be removed easily from the room side wiring plate by pushing up with a screwdriver. The cover can also be removed from the device easily with a screwdriver to access the light and sound output settings and a diagnostics test port for voltage testing. Removing cover Removing Device Page 2 of 7 Genesis LED EG4 Series horns, strobes, and horn-strobes mount to any standard one-gang, two-gang, 3.5-inch octagon, and 4-inch square electrical box. Matching optional EG4T trim rings are available to cover oversized openings. Optional color matched double-gang surface boxes are also available. Double Gang Electrical Box Trim Plate (optional) Wiring + Horn/strobe - circuit out Shorting clip DATA SHEET K85001-0668 Not to be used to1 installation purposes issue 1.3 Horn/strobe circuit in (signal polarity shown in the active condition) 03" (0.76 cm) 7.5" .05 cm) Diagnostics Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Page 3 of 7 Dimensions Field Configuration EG4 Notification Appliances Temporal horn and horn-strobe models are factory set to sound in 1.62" a three-pulse temporal pattern. By sliding the tone selector switch, (4.11 cm) 4.95" horn only models may be configured for constant horn output that -i (12.57 cm) can be coded at precise intervals by KIDDE control panels and l A control modules. Wel ::::::*00000o 0: g:::: Note: Temporal 3 coding is the required output for fire notification :::: : :: devices per NFPA 72. Any device coding other than temporal : :::: 3 is at the discretion and approval of the local authority having : :: jurisdiction (AHJ). 00 0000 ::::: Horns and horn-strobes are factory set for high dB output. Low 5.78" .000.0 0 : 00 0000 (14.68 cm) dB output may be selected by sliding the tone selector switch. :0 :: 00 9202 This reduces the output by about 6 dBA. i — —1 Genesis LED clear strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output. The output setting is changed by simply removing the cover and sliding the candela switch to the desired setting. The device does not have to be removed from the wall to change the output setting. The setting remains visible through a small window on the left-hand side of the device after the cover is closed. EG4T Trim Plate (optional) Light and Sound Output Settings (1) Constant, low dB (5) 110 candela (2) Constant, high dB (6) 75 candela (3) 13 temporal, low dB (7) 30 candela (4) T3 temporal, high dB (8)15 candela Operating current Horns Sound 16t033 16t033 setting VDC VFWR C-Low, 18 mA 22 mA T-Low Strobes Strobe 16to33 16t033 setting VDC VFWR 15, 30, 75,110 28 mA 36 mA C-High, 28 mA 38 mA T-Hicih Horn-Strobes Strobe setting Sound setting 16 to 33 VDC 16 to 33 VFWR 15, 30, C-Low, 1-Low 40 mA 48 mA 75,110 C-High, T-High 50 mA 60 mA DATA SHEET K85001-0668 Not to be used for installation purposes Issue 1.3 Light Distribution Horizontal Left 15 10 0 Horizontal Right 25 20 2025 30 -.-t160 30 35 --..-- 35 .14O 45 40 ' 40 45 50 55 50 55 60 j. 60 : 65 ''i--°65 S - ' 70. # 60-- 75_ -- It ,• I - 70 - 75 80 '/ 60- / -. :.. - i 80 - 85 85 . •- / 5 20 - ' 90. -.- . ,_- " --,-,-. 90 85 ----- '- -so - -It 75 . 7 7 65 60 r-,I.._ •_.__.l.• 55 50 45 - °- : 25 35 30 10 Vertical Bottom 0 5 Measured - - - UL Minumum Sound Output 40 Horn & Horn-Strobe Sound setting C-Low, T-Low C-High, T-High Reverberant Anechoic (UL464) (CANIULC - S525) 80dBA 86dBA 85dBA 92dBA Sound pattern (ULC) Axis Angle Change in output 135° and 45° -3dBA Horizontal 150° and 30° -6dBA 135° and 40° -3dBA Vertical 150° and 30° -6dBA Specifications .Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or TC3 temporal Light output 15, 30, 75, or 110 candela Strobe flash rate 1 fps (flash per second) approx. Synchronization 20 0 max. between any two devices. To determine allowed wire resistance, refer to these specifications, and the specifications for the synchronized signal source. Kidde CC Series Signal Modules, Booster and Auxiliary Power Supplies, Synchronization Sources Intelligent and Conventional Control Panels Wire size 12 to 18AWG (0,75 to 2.50 mm2) Dimensions (VVxHxD) 4.95 x 5.78 x 1.62 in (12.57 x 14.68 x 4.11 cm) Strobe-to-box center offset -1.70 inches (-4.32 cm) Compatible electrical boxes [1] 1-gang, 2-gang, 3.5-inch octagon, 4-inch square Trim plates EG4TR, EG4TW (5.6 x 7.5 x 0.3 in (14.22 x 1905 x 0.76 cm)) Operating environment Temperature 32 to 122°F (0 to 50°C) Relative humidity 0 to 93% noncondensing Storage Temperature -40 to 158 F (-40 to 70 C) [1] Electrical boxes must be at least 1-1/2 in. (3.81 cm) deep Page 4 of 7 DATA SHEET K85001-0668 Not to be used for installation purposes Issue 1.3 Ordering Information FOR REFERENCE ONLY 1!Replacement Appliance Covers Color Marking FIRE EG4ARF-CVR Red FIRE None !ilp:i EG4ARN-CVR Red None FIRE ii.iiA(ii EG4AWkCVR White ALERT None EG4AWF-CVR Horn Covers EG4AWN-CVR White White FIRE None FIRE None EO4VRF-CVR Red FIRE FIRE EG4VRN-CVR Red None None EG4ViNA-CVR White ALERT EG4W'/F-CVR White FIRE FIRE Strobe Covers EG4VWN-CVR White None None FIRE EG4AVRF-CVR Red FIRE None - EG4AVRN CVR Red None EG4AVWA-CVR White ALERT Wnrntrnh EG4AWF-CVR White FIRE EO4ARF Red EG4ARN Red EG4AWF White Horns EG4AWN White EG4VRF Red EG4VRN Red EG4WIF White Strobes EG4V\NN White _EG4AVRF Red EG4AVRN Red EG4A'vWF White Horn-strobes EG4AVvVN White Covers EG4AVWN-CVR White None I Accessories Room Side Wiring Trim plate, I EG4TW Trim plate, 04 Series, GP1O Plate (required, EG4TR 04 Series, red j white included with device) 13 27193-21 Two-gang surface 27193-26 Two-gang surface mount box, red mount box, white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers -Genesis Series Genesis Series EG4 = Wall mount appliances EG4 = Wall mount appliances Housing Color R Red Housing Color = W = White I = White Cover R = Red F Housing Marking L EG4AVRFCVR Designation N = None 1 Functions F = FIRE Lj F Cover Marking N = None Functions F = FIRE A = Horn only V = Strobe only A = Horn only A = ALERT AV = Horn-Strobe v = Strobe only AV = Horn-Strobe . Page 5of7 DATA SHEET K85001-0668 Not to be used for installation purposes Issue 1.3 0 or Kidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is Gamer brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. Page 6 of 6 DATA SHEET K85001-0668 Not to be used for installation purposes Issue 1.3 C CLIENUffC Edwards FILE NAF'93200 K85001 -0668 - Genesis LED EG4 Series 'aII Mount ART I DIRECTOR: (!)POWER PHOTOS: H OK NEED: N New Retouch ART/ICONS: m OK NEED: m New Edit COPY: H OK NEED: 9 New N Edit DATE: 05/5/20 NOTES: AE: I ART ACD: PROOFREADER: I WRITER ACID: >> ALWAYS SPELL CHECK << 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL $9- FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models G4ARF, G4ARF-FR, G4ARF-SP, G4ARN, G4AWF, G4AWF-FR, G4AWF-SP, G4AWN, G4A, G4A+F, G4A+F-FR, G4A+F-SP, G4A+N and G4A+ Wall or Ceiling Mounted Horns for indoor use. Models EG4ARF, EG4ARN, EG4AWF, EG4A, EG4AWN, EG4A+, EG4+F and EG4+N Wall or Ceiling Mounted Horns for indoor use. Models G4AVRF, G4AVRF-FR, G4AVRF-SP, G4AVRN, G4AVWF, G4AVWF-FR, G4AVWF-SP, G4AVWN, G4AV, G4AV+, G4AV+F, G4AV+F-FR, G4AV+F-SP and G4AV+N Wall Mounted Horn/Strobes for indoor use. Models EG4AVRF, EG4AVRN, EG4AVWF, EG4AV, EG4AVWN, EG4AV+, EG4AV+F and EG4AV+N Wall Mounted Horn/Strobes for indoor use. Models G4TR, G4TW and G4T+ Trim Plates. Models EG4TR, EG4TW and EG4T+ Trim Plates. Model GP Mounting Plate. *Models G4WSB, G4RSB, G4xxxSB, EG4WSB, EG4RSB, and EG4xxxSB Surface Backboxes. For models with an asterisk "+", the + can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color options other than red or white. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 Vdc/fwr Candela 15 cd, 30 cd, 75 cd, 110 cd selectable 82 dB at 10 feet INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and *Revision 1-12-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1tV* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other is Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No 7125-1657:0504 Page 2 of 2 ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. Models beginning with E are marked Kidde. APPROVAL: Listed as horns when used with a separately listed compatible fire alarm control unit. Units are suitable for indoor dry locations only. These units can generate a distinctive 3-Pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72. Listed as a horn or horn/strobe for the hearing impaired when used with separately listed electrically compatible fire aarm control units. The lights are only considered synchronized when used in conjunction with Listed Model G1M-RM (CSFM listing No. 7300-1657:0201) or Model SIGA-CC1S (CSFM listing No. 7300-1657:0121). Refer to listee's Installation Instruction Manual for details. *Revision 1-12-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should nct be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division . or KIdde P Strobes, Horns, Bells, Chimes Technology that saves lives Temporal Horns and Horn-strobes INT Series Patented 0 & 7125-1483: IVIEA 0133 S218 Overview Integrity temporal horns and temporal horn-strobes are specially designed for use with compatible life safety communication and control equipment to alert occupants of a life safety event. The horn emits a piercing low frequency sound that is easily heard above moderate ambient noise levels. The flash from its strobe can be noticed from almost any position in the room, corridor, or large open space. Integrity's rugged plastic housing is made from durable and fire retardant, high impact plastic with a slightly textured surface. Its ingenious mounting plate firmly holds the device in place with a single screw. A separate trim plate is not required. Terminals ac- cept up to #12 AWG (2.5mm2) wire for polarized connections. Strobes are shipped with standard wall mount style "FIRE" lens markings. Where ceiling orientation, other languages, or different lens markings are required, LKW and LKC series Lens Marking Kits are also available. These optional lens markings simply snap on to the strobe. Integrity horns and horn-strobes are designed for 16 to 33 Vdc operation and must be connected to signal circuits that output a constant (not pulsed) voltage. A diode is used to allow full signal circuit supervision. Standard Features UL 1971-listed synchronizing strobe Integrity strobes synchronize to the latest UL 1971 require- ments when used with a synchronization source. Adjustable Audible Output Select temporal or continuous tones, and High setting for 98 dBA output or Low setting for 94 dBA sound output. Genesis-compatible All Genesis and Integrity strobes on the same circuit meet UL 1971 synchronization requirements when used with an external control module. Approved for public and private mode applications UL 1971-listed as signaling devices for the hearing impaired and UL 1638-listed as protective visual signaling appliances. Durable red or white Noryl front plate Ideal for outdoor, industrial or harsh environments. Field changeable field markings Lens language or standard "FIRE" marking is easily changed with optional LKW and LKC series lens kits. Easy Installation Flush mount to standard North American 4" square or two- gang box. Integrity's universal mounting plate allows it to be wired and then left hanging free for easy inspection and testing before it is fastened to the electrical box. Page 1 086 DATA SHEET K85001-0341 Not to be Used for installation purposes Issue 1.1 Application S NOTE: The installation of visible and audible signals are subject to national and local standards, codes, and ordinances. Consult your Authority Having Jurisdiction for device installation requirements, application standards, and minimum performance specifications. Horns During installation, the horn is configured for steady or temporal tone signal and either low (94 dBA) or high (98 dBA) output. When temporal output is selected all horns on a common two-wire circuit are self-synchronized (see specifications). External control modules are not required for audible synchronization. Suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15dB above the average ambi- ent sound level, or 5dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5(1 .5m) above the floor. The average ambient sound level is the RMS, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Angle - Degree, 105 9585 75 dBA 758595105 —Temporal Horn (dBA) Typical Sound Output Distribution dBA measured at 10 ft in anechoic chamber INT Series Temporal Horn ('HIGH' output) Strobes Strobes are UL 1971-listed for use indoors as wall-mounted public- mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. As part of the Enhanced Integrity line of products, INT Series strobes exceed UL synchronization requirements (within 10 mil- liseconds other over a two-hour period) when used with a syn- chronization source. Synchronization is important in order to avoid epileptic sensitivity. Integrity strobes are fully compatible with Genesis Series signals. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. Kidde recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Installation and Mounting All models fit to a standard flush mounted, North-American two- Mounting Plate gang electrical box, 23/4 inch (69 mm) minimum. Optional flush trims are not required. For sur- face mount, use Kidde's custom indoor and outdoor surface boxes painted in color-matched red or white epoxy. Kidde recommends that fire alarm horn/strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. North American 2-gang electric box, 2%' (69mm) minimum (Alternative: 4" square box 2-1/8" (54mm) deep) CYO ~ screws (by others) Surface Box - 5-5/8" (143mm) sq. x 3-9/16" (91 mm) deep Mounting Screw (provided) Housing 5-1/2' (140mm) x 5-1/2' (140mm) x 5/8" (16mm) Page 2of6 DATA SHEET K850010341 Not to be used for installation purposes. Issue 1.1 S Typical Wiring The strobe must be connected to signal circuits which output a constant (not pulsed) voltage. The horn can be connected to continuous voltage circuits. HORN and STROBE FIRST DEVICE _________ I Horn/Strobe I ON SAME CIRCUIT Horn/Strobe __ To UL/1JLC Listed ___ Fire Alarm Control I Panel Signal Circuit I LT.N~ ' A ' Devico esistor HORN and STROBE ON SEPARATE CIRCUIT I FIRST DEVICE _____________ To UL/ULC Listed + I To Next Device Fire Alarm Corbel :i1 Horn/Strobe L Horn/Strobe I or SQL Resistor Panel Signal Circuit To IIL/ULC Listed + Fire Alarm Corbel - I Panel Signal Circuit rf ___________ __ To Next Strobe Device I or EOL Resistor Strobe Operating Current (RMS) UL Rating 15 c 15/75cd 30 c 75 c 110 c 16 Vdc 109 1 150 130 263 1 329 16Vfwr 150 1 210 189 333 1 420 Typical 15 c 15/75 Cd 30 c 75 c 110 Cd Current 24 Vdc 69 1 90 1 89 1 159 1 180 24Vfwr 108 1 128 1 134 1 255 1 260 Vdc: Volts direct current, regulated and filtered Vfwr: Volts full wave rectified Current Draw Notes and Comments Current values are shown in mA. UL Nameplate Rating can vane from Typical Current due to measurement meth- ods and instruments used. Kidde recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the 16 Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the 16 Vfr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current dBA Output Horn-strobes UL464 Average - anechoic Peak - anechoic Temporal Steady Temporal Steady Temporal Steady High dBOutput 79.0 85.0 97,0 97.0 102.0 102.0 Low dB Output 75.0 79.0 93.0 93.0 98.0 98.0 determines the heating affect and therefore, the trip and hold threshold for those Horns UL464 Average - anechoic Peak - anechoic Temporal Steady Temporal Steady Temporal Steady High dBOutput 82.0 85.0 98.0 98.0 104.0 104.0 Low dB Output 75.0 82.0 94.0 94.0 99.0 99.0 dBA Output Notes and Comments All values shown are dBA measured at 10 feet (3.01 m). UL1480 values measured in reverberation room. Average values are measured in anechoic chamber. Page 3 of 6 DATA SHEET K85001-0341 Not to be used for irstallatior, purposes. Issue 1.1 Light Output Patterns - u s iIffIrWs1sV!s 1lII Specifications Vertical -90" 90 90 Horizontal 90, Rated Strobe Output - candela (cd) INT-T INT-5AT I INT-7AT INT-3AT INT-8AT UL 1638 N/A (horn only) 15 cd (indoor only) 75 cd 30 cd 110 cd UL 1971 15 cd 15 cd wall I 30 cd wall 110 cd wa (wall mount only) 15 Cd ceiling I 15 cd ceiling 60 cd ceilinW ULCS526 15 cd 75 cd 30 cd 120 cd Standalone Synchronization Characteristics Strobe flash at 1 per second within 200 milliseconds on common circuit Horn pulses at temporal rate (note 2) within 200 milliseconds on common circuit Operating Volts Strobe: 16-33 Vdc or Vfwr Continuous Horn: 16-33 Vdc or Vfwr Continuous Anechoic: High Setting - 104 dBA (peak)/98 dBA (avg); Low Setting - 99 dBA (peak)/94 dBA (avg) Horn Output (note 1) Reverberent: High Setting - 85 dBA (continuous)/82 dBA (temporal); Low Setting - 82 dBA (continuous)/75 dBA (temporal) Horn Current High Output: 40 mA © 24 Vdc; 55mA © 24 Vrms FWR Low Output: 20 mA © 24 Vdc; 28 mA © 24 Vrms FWR Strobe Flash Synchronization Synchronized at one flash per second. External control module necessary to meet UL 1971 synchronization requirements of 10 milliseconds over a two-hour period. Synchronization Sources EG1M-RM, GSA-CC1S, 3SA-MCC1S, MIRBPS6A, MIRBPS1OA, APS6A, APS1OA Strobe Marking Supplied with LK\N-1 "FIRE" red letters, vertical both sides(Wall Mount) - see LKW and LKC series for ceiling style and optional markings. Flash Tube Enclosure Clear LEXAN with white marking sleeve Housing Textured, color impregnated engineered plastics - exceeds 94V-0 UL flammability rating Wire Connections Terminals - separate, polarized inputs for Horn & Strobe, #12 AWO (2.5mm2) maximum INDOOR Operating Environment 32-120" F (0-49" C) ambient temperature. 93% relative humidity @40" C OUTDOOR Operating Environment (must use 98% relative humidity © 40° C; -31-150" F (-35-66" C) ambient temperature weatherproof box) (INT-7A: rated at 17.7 cd © -35" C per UL/© -40" C per ULC) (lNT-8A: rated at 70.7 cd © -35° C per UL/@ -40° C per ULC) Mounting - INDOOR Flush: North-American 2-gang box, 3" high x 4" wide x 2%" (69 mm) minimum Surface: INT-SB Back box Bi-directional: INT-BDF Mounting Frame Mounting - OUTDOOR Surface: lNT-WB Weatherproof Box Agency Listings UL 1971, UL 1638, UL 464, ULCSS26, ULCSS2S, MEA, CSFM, FM (All models comply with ADA Code of Federal Regulation Cnapter 28 Part 36 Final Rule) Note 1 - Measured at 10 ft 13m1 @24 Vdc. Subtract 3 dBA for models with strobes. Note 2 - Temporal audible pattern is defined as: ½ sec ON, 1/ sec OFF, ½ sec ON, ½ sec OFF, 1/2 sec ON, 11/2 sec OFF, then repeat cycle. Integrity audible will rot be affected by Genesis signal silence operation when on the same two wire circuit with Genesis horn strobes. Page 4of6 DATA SHEET K85001-0341 Not to be used for installation purposes Issue 1.1 Lens Marking Kits (see note 1) LKN-1 "FIRE", Wall Orientation (supplied) LKVV-1 R "FIRE", Wall Orientation, RED LKN-2 "FEU", Wall Orientation - LKW-3 "FIRE/FEU", Wall Orientation LKN-4 "SMOKE", Wall Orientation LKW-5 0.1 05 "HALON", Wall Orientation LKW-6 "002", Wall Orientation LK\N-7 "EMERGENCY", Wall Orientation LKW-8 "ALARM", Wall Orientation LKW-9 "FUEGO", Wall Orientation LKW-10 "ALERT", Wall Orientation Add Suffix "W" to catalog no. for WHITE. (e.g. INT-7ATVtf Change "W" to "C" for CEILING mount. (e.g. LKC- 1) Ordering Information S Catalog Description Ship Wt., Number lb. (kg) Temporal Horns lNTT* Temporal Horn, Red 1.7 (0.8) Temporal Horn-Strobes INT7AT* Temporal Horn-Strobe, 15/75cd, Red lNT5AT* Temporal Horn-Strobe, 15cd, Red 2.0(0.9) lNT3AT* Temporal Horn-Strobe, 30cd, Red INT8AT* Temporal Horn-Strobe, llOcd, Red Synchronization Sources MEG1M-RM Genesis Signal Master Remote Mount 0.2 (0.1) (1-gang) GSA-CC1 S Synchronization Output Module 0.5 (0.23) (Standard Mount) - ULJULC Listed GSA-MCC1 S Synchronization Output Module (UIO 0.18 (0.08) Mount) - UL Listed MIRBPS6A 6.5 Amp Booster Power Supply 13(5.9) MIRBPS10A 10 Amp Booster Power Supply 13(5.9) Mounting Accessories lNTSB* Surface Box, Red, Indoor lNTWB* Weatherproof Box, Red, Surface 1.5(0.7) lNTBDF* Bi-directional Frame, Red 4(11.8) * Add -W for White housings. Page 5 of 6 DATA SHEET K85001-0341 Not to be USCO for r'tilIrtior purposs Issue 1.1 fl or Kidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. Page 6of6 DATA SP4EE1 K85001-0341 h tc e used fos intalI.a or urpoe. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0189 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models EST' 757-3A, *4A 757-5A, 757-6A, 757-7A and 757-8A, followed by suffix -MT, -MTW, -T or -TW horn strobe. Models "EST" 757H-15PS, 757H-15PSW, 757H-75P5 and 757H-75PSW horn strobes. Models 'Mirtone lNT-3A, INT-5A, INT-6A, INT-7A, INT-8A, followed by suffix -MT, -MTW, -T or -TW horn/strobes. These devices are combinations of and audible signal appliance and a visual signaling appliance Model 202-3A, -5A, -6A, -7A or -8A (See CSFM Listing 7125-1657:184 for details). Models with the letter "M" in the suffix are master units. Master units provide synchronization when used with slave units (models without "M" in the suffix). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Horn: 20-24 VDC Strobe (wall mount): -3A: 30 cd, -5A, -15:15 cd, -6A: 60 cd, -75: 75cd, *4A: 75 cd -7A:15/75 cd, -8A: 110 cd Strobe (ceiling mount): -3A: 15cd, -6A: 30 cd, -8A: 60 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. All units are intended for wall mount except for Models with suffix -3A, -6A and -8A are also suitable for ceiling mount. For ceiling mount strobes, the candela ratings are reduced as shown under rating. MARKING: Listee's name, model number, electrical/candela ratings and UL label. APPROVAL: Listed as audible/visual devices for use with separately listed compatible fire alarm control units. Suitable for the hearing impaired applications. Model Series 757H, 757-5A, and lNT-5A are for indoor use only. All other models are suitable for outdoor use. These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. NOTE: Formerly 7125-1591:189 and 7125-1388:214 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division