Loading...
HomeMy WebLinkAbout2628 GATEWAY RD; 120; FPC2019-0135; PermitPERMIT REPORT (_City of Carlsbad Print Date: 03/21/2022 Permit No: FPC2019-0135 Job Address: 2628 GATEWAY RD, # 120, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132621900 Track #: Applied: 06/12/2019 Valuation: $101,473.45 Lot #: Issued: 07/01/2019 Occupancy Group: Project #: Finaled Close Out: 05/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: BANTAMS ROOST -REVISED PLANS SPRINKLER TI (16 HEADS) FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 FIRE Plan Review Per Hour - Office Hours $136.00 Total Fees: $689.00 Total Payments To Date: $689.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Sully Fire Protection 1975 Spanish Oak Way Vista, California Cl6 701590 HYDRAULIC CALCULATIONS FOR Exterior Dining Area Bantam's Roost 2628 Gateway Road, Suite 120 Carlsbad, California 92009 FILE NAME: Bantam's Roost 2.sdf DATE: August 1, 2019 -Design Data- OCCUPANCY CLASSIFICATION: Light Hazard DENSITY: 0.10 gpm/ft2 AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS FLOWING: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE REQUIRED BOR: PRESSURE AVAILABLE AT BOR: SPRINKLER ORIFICE SIZE: Notes: All sprinklers LB = 225 ft2 maximum 4 sprinklers 131.8 gpm 231.8 gpm 131.8 gum @51.7 psi 61.8 psi Restaurant seating area meets the definition of a light hazard occupancy, per NFPA 13, §5.2, A.5.2.2 (14). Extended coverage horizontal sidewall sprinklers provided, meeting minimum flow and pressure requirements of 32.0 gum @ 32.7 psi for each flowing sprinkler, per manufacturer's data sheet for coverage area of 18' x 18', with sprinkler deflector 4" - 12" below ceiling. Available pressure and flow based on hydraulic calculation sign for existing system, designed for Ordinary Hazard Group 2, 0.20 gpm/ft2 , remote area 1,500 W. Sign shows flow and pressure required at base of riser is 423.78 gum @ 61.773 psi. This was used to establish supply data. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 8/1/2019 C:\HASS FILES\BANTAM'S ROOST 2.SDF JOB TITLE: Exterior Dining Area WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) BRE 62.0 61.3 423.0 61.8 231.8 51.7 Available pressure is 10.0 psi (16%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 231.8 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 131.8 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 11.5 K= 5.60 32.7 32.0 2 11.5 K= 5.60 35.0 33.1 21A 11.5 - - - - 44.9 - - - 3 11.5 K= 5.60 35.4 33.3 4 11.5 K= 5.60 35.2 33.2 2A 11.0 - - - - 45.0 - - - 3A 11.0 - - - - 45.0 4A 11.0 - - - - 45.0 - - - 16 11.0 - - - - 46.0 - - - 21 11.0 - - - - 46.0 - - - 22 11.0 - - - - 46.2 - - - B2 11.0 - - - - 46.1 - - - B1 11.0 - - - - 46.1 - - - TRE 11.0 - - - - 46.9 BRE 0.0 SOURCE 51.7 131.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/1/2019 C:\HASS FILES\BANTAM'S ROOST 2.SDF JOB TITLE: Exterior Dining Area PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -32.0 1.049 PL 22.00 PF 12.1 1 11.5 5.6 32.7 32.0 11.9 120 FTG 6ET PH 0.2 2A 11.0 0.0 45.0 0.0 0.311 TL 39.00 PV Pipe: 2 -33.1 1.049 PL 16.75 PF 9.8 2 11.5 5.6 35.0 33.1 12.3 120 FTG 4ET PE 0.0 21A 11.5 0.0 44.9 0.0 0.331 TL 29.75 PV Pipe: 3 -33.3 1.049 PL 12.83 PF 9.3 3 11.5 5.6 35.4 33.3 12.4 120 FTG 5ET PE 0.2 3A 11.0 0.0 45.0 0.0 0.335 TL 27.83 PV Pipe: 4 -33.2 1.049 PL 13.99 PF 9.6 4 11.5 5.6 35.2 33.2 12.3 120 FTG SET PH 0.2 4A 11.0 0.0 45.0 0.0 0.333 TL 28.99 PV Pipe: 6 -32.0 1.740 PL 28.00 PF 1.0 2A 11.0 0.0 45.0 0.0 4.3 120 FTG T PE 0.0 16 11.0 0.0 46.0 0.0 0.026 TL 37.80 PV Pipe: 7 -33.3 1.740 PL 28.00 PF 1.1 3A 11.0 0.0 45.0 0.0 4.5 120 FTG T PH 0.0 Hi 11.0 0.0 46.1 0.0 0.028 TL 37.80 PV Pipe: 8 -33.2 1.740 PL 26.00 PF 1.0 4A 11.0 0.0 45.0 0.0 4.5 120 FTG T PH 0.0 B2 11.0 0.0 46.1 0.0 0.028 TL 35.80 PV Pipe: 9A -33.1 1.740 PL 25.00 PF 1.0 21A 11.5 0.0 44.9 0.0 4.5 120 FTG T PE 0.2 21 11.0 0.0 46.0 0.0 0.028 TL 34.80 PV Pipe: 10 -32.0 3.316 PL 10.00 PF 0.0 16 11.0 0.0 46.0 0.0 1.2 120 FTG ---- PE 0.0 21 11.0 0.0 46.0 0.0 0.001 TL 10.00 PV Pipe: bA -65.2 3.316 PL 5.00 PF 0.1 21 11.0 0.0 46.0 0.0 2.4 120 FTG T PH 0.0 22 11.0 0.0 46.2 0.0 0.004 TL 24.70 PV Pipe: 11 66.6 3.316 PL 1.00 PF 0.1 22 11.0 0.0 46.2 0.0 2.5 120 FTG T PE 0.0 BI 11.0 0.0 46.1 0.0 0.004 TL 20.70 PV Pipe: 12 33.2 3.316 PL 9.50 PF 0.0 Bi 11.0 0.0 46.1 0.0 1.2 120 FTG ---- PH 0.0 B2 11.0 0.0 46.1 0.0 0.001 TL 9.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/1/2019 C:\HASS FILES\BANTAM'S ROOST 2.SDF JOB TITLE: Exterior Dining Area PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 131.7 3.316 PL 33.00 PF 0.8 TRE 11.0 0.0 46.9 0.0 4.9 120 FTG 2E PE 0.0 22 11.0 0.0 46.2 0.0 0.016 TL 48.00 PV Pipe: 14 131.8 4.316 PL 15.00 PF 0.1 BRE 0.0 SRCE 51.7 (N/A) 2.9 120 FTG ---- PE -4.8 TRE 11.0 0.0 46.9 0.0 0.004 TL 15.00 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 50110279 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.032 gpm and a maximum imbalance at any node of 0.453 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.4 ft/sec at pipe 3. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node BRE under full flow conditions is 61.73 psi with a flow of 245.23 gpm. PIPE FITTINGS TABLE User Pipe Table Name: KEN CUSTOM.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/1/2019 C:\HASS FILES\BANTAM'S ROOST 2.SDF JOB TITLE: Exterior Dining Area PAGE: A MATERIAL: 40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli T LngEil ChkViv BfyViv GatViv AimChk DPVlv BlHdTe -------------------------------------------------------- R K TeeRun TeeRun 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 2.00 2.00 PAGE: Y MATERIAL: Mega-Flow HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 45 Check BtrFly GateVi 1.740 3.90 9.80 0.00 0.00 0.00 0.00 0.00 0.00 3.316 7.50 19.70 0.00 0.00 0.00 0.00 0.00 0.00 4.316 9.60 22.70 0.00 0.00 0.00 0.00 0.00 0.00 P R E S S U R E 80.0 70.0 G A u 60.0 A G E 50.0 40.0 30.0 20.0 10.0 P 0.0 p S I WATER SUPPLY ANALYSIS Static: 62.00 psi Resid: 61.27 psi Flow: 423.0 gpm -14.7 Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 8/1/2019 C:\HASS FILES\BANTAM'S ROOST 2.SDF JOB TITLE: Exterior Dining Area WATER SUPPLY CURVE 72+ 66+ *\\\Q\\\\\\\\* <-61.3 psi @ 423 gpm 60+ Flow Test Point 54+ X P 48+ R I E I S I S 42+ U R I E I 36+ P I S I 30+ 24+ 18+ 12+ LEGEND 'p I X = Required Water Supply I 51.74 psi 8 231.8 gpm 6+ I 0 = Available Water Supply 61.76 psi 8 231.8 gpm -------+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) 17 SERIES GL-QRIECLH!SW EXTENDED COVERAGE RECESSED HORIZONTAL SIDEWALL QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD A U TOMA TiC SPRiNKLERS GL5628 HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL5628 Extended Coverage Hori- zontal Sidewall Sprinkler is a low profile yet durable design which utilizes a 3m frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While these Quick Response Sprinklers provide an aesthetically pleasing appearance, they can be installed wherever standard extended coverage horizontal sprinklers are specified; but offer the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direc- tion of approving authorities having jurisdiction, in accordance with their listings and in accordance with NFPA 13. The heart of Globe's Series GL-QR sprinkler proven actuating as- sembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Bulb seat - copper • Spring - nickel alloy 'Seal - teflon Bulb - glass with alcohol based solution, 3mm size Escutcheon Assembly - steel SERIES GL-QRIECLH/SW EXTENDED COVERAGE HORIZONTAL SIDEWALL *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING A CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR I N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 1351th5F 7°CI68° ORANGE/RED r 100F 38C INTERMEDIATE V 175Fi2r r 7CIJ3'C YELLOW/GREEN 150T MAR 2019 GFS-220 (Formerly A-44) ADJ. RECESSED ESCUTCHEON PART NUMBERS FRICTION FIT THREADED WHITE CHROME WHITE CHROME 325426-W 325422 329308-W 329306 RJ 12' MX 2' MIN. DIA ORDERING INFORMATION SPECIFY ° Quantity o SIN Style o Orifice ° Thread Size 'Temperature • Finishes desired ° Quantity - Wrenches - P/N 325390 Quantity - Recessed Escutcheons Quantity - Recessed Wrenches - P/N 325391 Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) MAR 2019 QuicK RESPONSE EXTENDED COVERAGE LIGHT HAZARD AUTOMATIC SPRINKLERS GL5628 HORIZONTAL SIDEWALL ° RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS AND APPROVALS SIN NOMINAL NOMINAL THREAD SIZE LENGTH FINISHES cULus Factory Bronze GL5628 5.6 (80 metric) 1/2°NPT (15mm) 2 1/2" (6.4cm) Chrome White Polyester' Black Polyester' .2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 2AVAILABLE AS cULus LISTED AS CORROSION RESISTANT WHEN SPECIFIED ON ORDER. cULus LISTING DESIGN - USE REQUIREMENTS FOR LIGHT HAZARDS ONLY SIN STYLE TEMPERATURE MAX. AREA OF COVERAGE WIDTH x LENGTH Feet (Meters) MIN. PRESSURE PSI (bars) MIN. FLOW G.PM. (Umin.) DEFLECTOR TO CEILING DISTANCE inches (mm) MIN. DISTANCE BETWEEN SPRINKLERS Feet (Meters) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) GL5628 HORIZONTAL SIDEWALL X X X X 16(4.9) x 16(4.9) 21.6(l.49) 26(98) 4 (102) to 12(305) 32 (125) 8(2.4) x X X X ° 16(4.9) x 18(5.5) 26.8(l.85) 29(110) x - X - 16 (4.9) x 20 (6.1) 32.7 (2.25) 32 (125) X X I X X** 18(5.5) x 18 (5.5) 32.7(2.25) 32 (125) RECESSED- HORIZONTAL SIDEWALL X - X - X - X 16(4.9) x 16(4.9) 21.6 (1.49) 26(98) X X X X'" 16(4.9) x 18(5.5) 26.8 (1.85) 29(110) X - - - 16(4.9) x 20 (6.1) 32.7 (2.25) 32 (125) X X X X° 18 (5.5) x 18 (5.5) 32.7 (2.25) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH DESIGN CRITERIAARE STATED. **200F (93" C) LISTED AT 4" (102) TO 6" (152) CROSS SECTION DEFLECTOR DISTANCE FROM CEILING Ir RETAINER 118' MIN. 1"MIN. 118' MX. 13/4' MAX (314") ADJUSTMENT RECESSED HORIZONTAL SIDEWALL GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U.S.A. GFS-220 (Formerly A-44)