HomeMy WebLinkAbout2330 FARADAY AVE; 200; FPC2017-0295; PermitPERMIT REPORT ('(PZ"ity of Carlsbad Print Date: 05/18/2021 Permit No: FPC2017-0295 Job Address: 2330 FARADAY AVE, #200, CARLSBAD, CA 92008-7216 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120612800 Valuation: $339,988.10 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 10/16/2017 Issued: 10/31/2017 Finaled Close Out: 02/23/2021 Inspector: Final Inspection: Project Title: Description: EPICOR -SPRINKLER TI 7-100 (28) OFFICE TO OFFICE Applicant: FPContractor: A & D FIRE SPRINKLER INC A & D FIRE SPRINKLERS INC DEVIN KRENZ 7130 CONVOY CT 7130 CONVOY CT SAN DIEGO, CA 92111-1019 SAN DIEGO, CA 92111-1019 (858) 277-3473 (858) 277-3473 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $668.00 Total Payments To Date: $668.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ffczo t.:1 o2-9' FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS INC. 7130 CONVOY COURT SAN DIEGO, CA 92111 858-277-3473 Job Name : EPICOR Building Location System Contract Data File : EPICOR AREA 1 .WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C A&D FIRE SPRINKLERS INC. Page EPICOR Date City Water Supply: Demand: Cl - Static Pressure : 96 Dl - Elevation : 3.898 C2 - Residual Pressure: 90.53 D2 - System Flow :152.76 C2 - Residual Flow : 1084.93 D2 - System Pressure : 46.358 Hose ( Demand) D3 - System Demand : 152.76 Safety Margin : 49.496 150 140 130 120 ---1- R11° 100 90 s 80 - ______ _________ _____________ u 70 R6° nil 50 E 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N l 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary A&D FIRE SPRINKLERS INC. Page 2 1 EPICOR Date Fitting Legend Abbrev. Name 1/2 % 1 11/4 1'/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD A&D FIRE SPRINKLERS INC. Page 3 EPICOR Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 9.0 5.6 16.14 na 22.5 0.1 225 7.0 2 11.0 17.36 na 3 11.0 21.33 na 4 15.92 33.81 na 7 15.92 35.31 na 8 15.17 35.78 na 9 15.17 35.84 na 10 15.17 35.89 na 11 14.33 36.88 na TOR 14.33 37.02 na BOR 0.0 46.36 na 5 9.0 5.6 16.48 na 22.73 0.1 225 7.0 6 11.0 17.73 na 12 9.0 5.6 17.32 na 23.31 0.1 225 7.0 13 9.0 5.6 17.68 na 23.55 0.1 225 7.0 54 15.92 34.77 na 44 14.5 35.77 na 43 14.5 35.84 na 42 14.5 35.88 na 41 14.5 35.91 na 40 14.5 35.93 na 39 14.5 35.93 na 38 14.5 35.93 na 37 15.67 35.43 na 36 15.67 35.48 na 35 15.17 35.7 na 34 15.17 35.7 na 33 15.17 35.72 na 32 15.17 35.72 na 31 15.17 35.73 na 30 15.17 35.74 na 29 15.17 35.75 na 70 9.0 5.6 29.23 na 30.28 0.1 225 7.0 71 15.75 29.33 na 72 15.75 34.67 na 27 15.75 35.46 na 73 9.0 5.6 29.46 na 30.4 0.1 225 7.0 55 15.75 35.13 na 45 14.5 35.77 na 46 14.5 35.82 na 47 14.5 35.85 na 48 14.5 35.85 na 49 15.08 35.63 na 50 15.08 35.89 na 51 15.17 35.87 na 52 15.17 35.87 na 53 15.17 35.88 na 56 15.58 35.38 na 57 15.58 35.68 na 58 16.25 35.1 na 59 16.25 35.27 na 60 15.33 35.51 na 61 15.33 35.78 na 62 16.5 35.03 na 63 16.5 35.15 na 64 16.42 35.09 na 65 16.42 35.18 na 66 16.08 35.25 na 67 16.08 35.32 na 68 15.83 35.36 na 69 15.83 35.41 na The maximum velocity is 21.13 and it occurs in the pipe between nodes 71 and 72 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS INC. Page 4 EPICOR Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 22.50 1.083 E 2.336 12.670 16.143 K Factor = 5.60 to 120.0 0.0 2.336 -0.866 2 22.5 0.1385 0.0 15.006 2.079 Vet = 7.84 2 23.31 1.083 E 2.336 5.360 17.356 to 120.0 0.0 2.336 0.0 3 45.81 0.5161 0.0 7.696 3.972 Vel = 15.95 3 46.28 1.418 2T 13.697 8.360 21.328 to 120.0 2E 6.849 20.546 -2.131 4 92.09 0.5055 0.0 28.906 14.613 Vel = 18.71 4 -56.91 2.067 5E 25.0 85.070 33.810 to 120.0 0.0 25.000 0.0 7 35.18 0.0136 0.0 110.070 1.497 Vel = 3.36 7 0.0 2.067 T 10.0 0.750 35.307 to 120.0 0.0 10.000 0.325 8 35.18 0.0136 0.0 10.750 0.146 Vet = 3.36 8 44.58 3.26 0.0 9.300 35.778 to 120.0 0.0 0.0 0.0 9 79.76 0.0068 0.0 9.300 0.063 Vel = 3.07 9 32.68 3.26 0.0 4.070 35.841 to 120.0 0.0 0.0 0.0 10 112.44 0.0125 0.0 4.070 0.051 Vel = 4.32 10 40.32 3.26 1 20.159 0.830 35.892 to 120.0 L 6.72 26.879 0.364 11 152.76 0.0224 0.0 27.709 0.620 Vel = 5.87 11 0.0 4.26 0.0 23.170 36.876 to 120.0 0.0 0.0 0.0 TOR 152.76 0.0061 0.0 23.170 0.141 Vel = 3.44 TOR 0.0 4.26 L 7.9 14.330 37.017 to 120.0 Fsp 0.0 7.900 9.206 * Fixed Loss = 3 BOR 152.76 0.0061 0.0 22.230 0.135 Vet = 3.44 0.0 152.76 46.358 KFactor= 22.44 5 22.73 1.083 E 2.336 12.670 16.479 K Factor 5.60 to 120.0 0.0 2.336 -0.866 6 22.73 0.1412 0.0 15.006 2.119 Vel = 7.92 6 23.55 1.083 E 2.336 4.500 17.732 to 120.0 0.0 2.336 0.0 3 46.28 0.5260 0.0 6.836 3.596 Vet = 16.12 0.0 46.28 21.328 K Factor 10.02 12 23.31 1.083 T 5.84 0.250 17.322 K Factor = 5.60 to 120.0 0.0 5.840 -0.866 2 23.31 0.1478 0.0 6.090 0.900 Vet = 8.12 0.0 23.31 17.356 K Factor = 5.60 13 23.55 1.083 T 5.84 0.250 17.680 K Factor = 5.60 to 120.0 0.0 5.840 -0.866 6 23.55 0.1507 0.0 6.090 0.918 Vet = 8.20 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC. Page 5 EPICOR Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 23.55 17.732 K Factor= 5.59 4 56.91 2.067 T 10.0 19.090 33.810 to 120.0 0.0 10.000 0.0 54 56.91 0.0331 0.0 29.090 0.963 Vel = 5.44 54 0.0 2.067 T 10.0 1.420 34.773 to 120.0 0.0 10.000 0.615 44 56.91 0.0331 0.0 11.420 0.378 Vel = 5.44 44 -12.33 2.635 0.0 11.060 35.766 to 120.0 0.0 0.0 0.0 43 44.58 0.0065 0.0 11.060 0.072 Vel = 2.62 43 -10.56 2.635 0.0 12.000 35.838 to 120.0 0.0 0.0 0.0 42 34.02 0.0039 0.0 12.000 0.047 Vel = 2.00 42 -8.63 2.635 0.0 12.000 35.885 to 120.0 0.0 0.0 0.0 41 25.39 0.0022 0.0 12.000 0.027 Vel = 1.49 41 -7.33 2.635 0.0 12.000 35.912 to 120.0 0.0 0.0 0.0 40 18.06 0.0012 0.0 12.000 0.015 Vel = 1.06 40 -6.57 2.635 0.0 12.000 35.927 to 120.0 0.0 0.0 0.0 39 11.49 0.0005 0.0 12.000 0.006 Vel = 0.68 39 -5.83 2.635 0.0 12.000 35.933 to 120.0 0.0 0.0 0.0 38 5.66 0.0002 0.0 12.000 0.002 Vel = 0.33 38 0.0 2.067 T 10.0 1.170 35.935 to 120.0 0.0 10.000 -0.507 37 5.66 0.0004 0.0 11.170 0.005 Vel= 0.54 37 0.0 2.067 T 10.0 82.950 35.433 to 120.0 E 5.0 15.000 0.0 36 5.66 0.0005 0.0 97.950 0.046 Vel = 0.54 36 0.0 2.067 T 10.0 0.500 35.479 to 120.0 0.0 10.000 0.217 35 5.66 0.0004 0.0 10.500 0.004 Vel = 0.54 35 0.0 2.635 0.0 12.000 35.700 to 120.0 0.0 0.0 0.0 34 5.66 0.0002 0.0 12.000 0.002 Vel = 0.33 34 5.83 2.635 2L 10.983 25.500 35.702 to 120.0 0.0 10.983 0.0 33 11.49 0.0005 0.0 36.483 0.019 Vel = 0.68 33 0.0 3.26 0.0 6.090 35.721 to 120.0 0.0 0.0 0.0 32 11.49 0.0002 0.0 6.090 0.001 Vel = 0.44 32 6.57 3.26 0.0 12.000 35.722 to 120.0 0.0 0.0 0.0 31 18.06 0.0004 0.0 12.000 0.005 Vel = 0.69 31 7.33 3.26 0.0 12.000 35.727 to 120.0 0.0 0.0 0.0 30 25.39 0.0008 0.0 12.000 0.010 Vel = 0.98 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC. Page 6 EPICOR Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 30 8.63 3.26 0.0 12.000 35.737 to 120.0 0.0 0.0 0.0 29 34.02 0.0014 0.0 12.000 0.017 Vel = 1.31 29 10.56 3.26 0.0 10.680 35.754 to 120.0 0.0 0.0 0.0 8 44.58 0.0022 0.0 10.680 0.024 Vel = 1.71 0.0 44.58 35.778 K Factor = 7.45 70 30.28 1.083 1 5.84 6.750 29.230 K Factor = 5.60 to 120.0 0.0 5.840 -2.923 71 30.28 0.2400 0.0 12.590 3.021 Vel = 10.55 71 30.39 1.083 T 5.84 0.320 29.328 to 120.0 0.0 5.840 0.0 72 60.67 0.8680 0.0 6.160 5.347 Vel = 21.13 72 -27.99 2.067 E 5.0 61.490 34.675 to 120.0 0.0 5.000 0.0 27 32.68 0.0119 0.0 66.490 0.789 Vel = 3.12 27 0.0 2.067 T 10.0 0.580 35.464 to 120.0 0.0 10.000 0.251 9 32.68 0.0119 0.0 10.580 0.126 Vel = 3.12 0.0 32.68 35.841 K Factor = 5.46 73 30.40 1.083 E 2.336 9.200 29.463 K Factor = 5.60 to 120.0 0.0 2.336 -2.923 71 30.4 0.2417 0.0 11.536 2.788 Vel = 10.59 0.0 30.40 29.328 K Factor= 5.61 72 28.00 2.067 T 10.0 41.050 34.675 to 120.0 0.0 10.000 0.0 55 28.0 0.0089 0.0 51.050 0.455 Vel = 2.68 55 0.0 2.067 T 10.0 1.250 35.130 to 120.0 0.0 10.000 0.541 45 28.0 0.0090 0.0 11.250 0.101 Vel = 2.68 45 12.33 2.635 0.0 8.980 35.772 to 120.0 0.0 0.0 0.0 46 40.33 0.0053 0.0 8.980 0.048 Vel = 2.37 46 -14.21 2.635 0.0 11.020 35.820 to 120.0 0.0 0.0 0.0 47 26.12 0.0024 0.0 11.020 0.026 Vel = 1.54 47 -12.92 2.635 0.0 12.000 35.846 to 120.0 0.0 0.0 0.0 48 13.2 0.0007 0.0 12.000 0.008 Vel = 0.78 48 0.0 2.067 T 10.0 0.580 35.854 to 120.0 0.0 10.000 -0.251 49 13.2 0.0023 0.0 10.580 0.024 Vel = 1.26 49 0.0 2.067 T 10.0 102.530 35.627 to 120.0 E 5.0 15.000 0.0 50 13.2 0.0022 0.0 117.530 0.261 Vel = 1.26 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC. Page 7 EPICOR Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 50 0.0 2.067 T 10.0 0.080 35.888 to 120.0 0.0 10.000 -0.039 51 13.2 0.0022 0.0 10.080 0.022 Vel = 1.26 51 0.0 3.26 0.0 12.440 35.871 to 120.0 0.0 0.0 0.0 52 13.2 0.0002 0.0 12.440 0.003 Vel = 0.51 52 12.92 3.26 0.0 10.600 35.874 to 120.0 0.0 0.0 0.0 53 26.12 0.0008 0.0 10.600 0.009 Vel = 1.00 53 14.21 3.26 0.0 4.900 35.883 to 120.0 0.0 0.0 0.0 10 40.33 0.0018 0.0 4.900 0.009 Vel = 1.55 0.0 40.33 35.892 KFactor 6.73 44 12.33 2.635 0.0 8.940 35.766 to 120.0 0.0 0.0 0.0 45 12.33 0.0007 0.0 8.940 0.006 Vel = 0.73 0.0 12.33 35.772 K Factor = 2.06 46 14.20 2.067 T 10.0 1.080 35.820 to 120.0 0.0 10.000 -0.468 56 14.2 0.0025 0.0 11.080 0.028 Vel = 1.36 56 0.0 2.067 T 10.0 102.530 35.380 to 120.0 E 5.0 15.000 0.0 57 14.2 0.0025 0.0 117.530 0.299 Vel = 1.36 57 0.0 2.067 T 10.0 0.420 35.679 to 120.0 0.0 10.000 0.178 53 14.2 0.0025 0.0 10.420 0.026 Vel = 1.36 0.0 14.20 35.883 K Factor = 2.37 43 10.56 2.067 T 10.0 1.750 35.838 to 120.0 0.0 10.000 -0.758 58 10.56 0.0014 0.0 11.750 0.017 Vel = 1.01 58 0.0 2.067 T 10.0 102.530 35.097 to 120.0 E 5.0 15.000 0.0 59 10.56 0.0015 0.0 117.530 0.173 Vel = 1.01 59 0.0 2.067 T 10.0 1.080 35.270 to 120.0 0.0 10.000 0.468 29 10.56 0.0014 0.0 11.080 0.016 Vel = 1.01 0.0 10.56 35.754 K Factor 1.77 47 12.92 2.067 T 10.0 0.830 35.846 to 120.0 0.0 10.000 -0.359 60 12.92 0.0021 0.0 10.830 0.023 Vel = 1.24 60 0.0 2.067 T 10.0 102.970 35.510 to 120.0 3E 15.0 25.000 0.0 61 12.92 0.0021 0.0 127.970 0.273 Vel = 1.24 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC. Page 8 EPICOR Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 61 0.0 2.067 T 10.0 0.170 35.783 to 120.0 0.0 10.000 0.069 52 12.92 0.0022 0.0 10.170 0.022 Vel = 1.24 0.0 12.92 35.874 K Factor= 2.16 42 8.63 2.067 T 10.0 2.000 35.885 to 120.0 0.0 10.000 -0.866 62 8.63 0.0010 0.0 12.000 0.012 Vel = 0.83 62 0.0 2.067 T 10.0 102.540 35.031 to 120.0 E 5.0 15.000 0.0 63 8.63 0.0010 0.0 117.540 0.118 Vel = 0.83 63 0.0 2.067 T 10.0 1.330 35.149 to 120.0 0.0 10.000 0.576 30 8.63 0.0011 0.0 11.330 0.012 Vel = 0.83 0.0 8.63 35.737 K Factor= 1.44 41 7.33 2.067 T 10.0 1.920 35.912 to 120.0 0.0 10.000 -0.832 64 7.33 0.0008 0.0 11.920 0.010 Vel = 0.70 64 0.0 2.067 T 10.0 102.530 35.090 to 120.0 E 5.0 15.000 0.0 65 7.33 0.0007 0.0 117.530 0.087 Vel = 0.70 65 0.0 2.067 T 10.0 1.250 35.177 to 120.0 0.0 10.000 0.541 31 7.33 0.0008 0.0 11.250 0.009 Vel = 0.70 0.0 7.33 35.727 K Factor = 1.23 40 6.57 2.067 T 10.0 1.580 35.927 to 120.0 0.0 10.000 -0.684 66 6.57 0.0006 0.0 11.580 0.007 Vel = 0.63 66 0.0 2.067 T 10.0 102.540 35.250 to 120.0 E 5.0 15.000 0.0 67 6.57 0.0006 0.0 117.540 0.071 Vel = 0.63 67 0.0 2.067 T 10.0 0.920 35.321 to 120.0 0.0 10.000 0.394 32 6.57 0.0006 0.0 10.920 0.007 Vel = 0.63 0.0 6.57 35.722 K Factor= 1.10 39 5.84 2.067 1 10.0 1.330 35.933 to 120.0 0.0 10.000 -0.576 68 5.84 0.0005 0.0 11.330 0.006 Vel = 0.56 68 0.0 2.067 1 10.0 82.950 35.363 to 120.0 E 5.0 15.000 0.0 69 5.84 0.0005 0.0 97.950 0.048 Vel = 0.56 69 0.0 2.067 T 10.0 0.670 35.411 to 120.0 0.0 10.000 0.286 34 5.84 0.0005 0.0 10.670 0.005 Vel = 0.56 0.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC. Page 9 EPICOR Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 5.84 35.702 K Factor= 0.98 Computer Programs by Hydratec Inc. Revision: 50.52.1 uca Worldwide i Fire Protection Contacts www.tyco-fire.com tq Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi"2 (80,6 LPM/bar"2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector. can be provided on special request. 1/20 7/16(11,1 mm) NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON ESCUTCHEON PLATE 6 - Deflector" DEFLECTOR* SEATING SURFACE 7/16' 1 \ (11,1 mm) NOMINAL 2' MAKE-IN / (50,8 mm) 20 _ 1-3/8" (50,8 mm) (34,9 mm) I 1/2" NPT** DEFLECTOR * 2-7/8' (73,0 mm) DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. ^WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF - (57,2 mm) SPRINKLER FITTING ___________ FLUSH 3/8±5/16 (9,5±7,9 mm) 5/8 (15,9 mm) MOUNTING/K \ 1/8" J I SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4 (19,1 mm) FIGURE 4 SERIES TY.FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4 1/2(12,7mm) (7,9±6,4 mm) FLUSH / MOUNTING / 1/8' J SURFACE/ \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TVFRB PLATE 7/8 (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I SPRINKLER TEMPERATURE FINISH -J- RATINGS SIN 1 NATURAL BRASS I 370 I 5.6K UPRIGHT (1/2 NPT) TY313 3 PURE WHITE (RAL9010)°° 155 155-F (68-C) POLYESTER 371 5.6K PENDENT (1/2 NPT) TY323 4 SIGNAL WHITE (RAL9003) 175 175-F (79-C) POLYESTER * Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - ** Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 4 135 135-F (57-C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqco Worldwide Contacts www.tyco-fire.com Series RFII - 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1!2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFll Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM!p5i1/2 (80,6 LPM/barl/2) Adjustment 1!2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPI8I TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins — then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NPT FRAME SUPPOR CUP WITI ROLL FORry THREAD GUIDE PINS (2) Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200° F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFll Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and DEFLECTOR i SPRINKLER/SUPPORT CUP ASSEMBLY LECTOR ROPPED POSITION) EALING SEMBLY CAP BULB PRESSION CREW THREAD INTO Jj RETAINER SUPPORT fi WITH THREAD CUP UNTIL 0 0 %— DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING 1••I SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY I I I I -\ MANUFACTURER DEFLECTOR COVER PLATE PRESET GAP IN DROPPED RETAINER 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE DIAMETER DIMENSION A 3/16to11/16 (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPIBI Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER - DIMENSION C Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. L'L.J1(.I As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate/ Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. .-! P TFPI8I Page 4 of 4 Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 166'F (68-C) 200°F (93°C TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. tq a Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TYL - 56 and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-L, 5.6 and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response -standard cover- age, solder type spray sprinklers de- signed for use in light, ordinary, and extra hazard, commercial occupan- cies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc. The recessed version of the Series TY-L Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjust- ment or up to 1/2 in. (12,7 mm) of to- tal adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitabil- ity of these coatings for any given cor- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 rosive environment. The effects of am- bient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-L Pendent Sprinkler can be obtained by utilizing the Series TY-L Pendent Sprinkler in combination with the Model S Shield. NOTICE The TYCO Series TY-L, 5.6 and 8.0 K- factor, Upright and Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the ap- plicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3111......Upright 5.61K, 1/2" NPT TY3211 . . . . Pendent 5.61K, 1/2" NPT TY4111 .....Upright 8.01K, 3/4" NPT TY4211.....Pendent 8.01K, 3/4" NPT TY4811 .....Upright 8.01K, 1/2" NPT TY4911 . . . . Pendent 8.01K, 1/2" NPT TY3111 is a re-designation for S1800 and G3111. 1Y3211 is a re-designation for S1801 and G3112. TY4111 is a re-designation for S1810 and G3101. TY4211 is a re-designation for S1811 and G3102. 1Y4811 is a re-designation for S1805. TY4911 is a re-designation for S1806. MAY 2014 TFPIIO TFPIIO Page 2 of 6 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE 1 - Frame 3 - Ejection 2 - Sealing Spring Button 4 - Fusible Element 5 - Strut 6 - Hook 7 - Deflector* WRENCI AREA ,22 (50,8 mm) L STYLE RECESSI ESCUTCHI 2-7/8" (73,0 mm) DIA. 1/2" NPT** t WRENCH FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 1 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY3III) AND PENDENT (TY3211) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Ejection 5 - Strut is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Sealing Spring 6 - Hook Deflector. special request. PLATE SEATING Button 4 - Fusible 7 - Deflector* SURFACE Element 0- _______ - 'Alk .. WRENC AREA 1/2 (12,7 mm) (6;! mm) trf1- NOMINAL MAKE-IN STYLE (50,8 mm) L ESCUTCF WRENCH 2-7/8" (73,0 mm) DIA. FLANGES 3/4 NPT** UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 2 STANDARD RESPONSE SERIES TY-L UPRIGHT (TV4III) AND PENDENT (TY4211) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT TFPIIO Page 3 of 6 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector, special request. PLATE SEATING SURFACE 1 2-5/8 1 - Frame 3 - Ejection 5 - Strut 2 - Sealing Spring 6 - Hook Button 4 - Fusible 7 - Deflector* Element I 2-5/8 (66,7 mm), 7/16" (11,1 mm) I NOMINAL I I MAKE-IN I 1/2" NPT** I WRENCH FLANGES WREN( AREA (66,7 mm) STYLE I 1(50,8mm) RECES ESCUTCI L 2-7/8 (73,0 mm) DIA. UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 3 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY4811) AND PENDENT (TY4911) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, and LPCB Approved. (Refer to Table A for com- plete approval information including corrosion resistant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/barl/2) K=8.0 GPM/psi1l2 (115,2 LPM/barl/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ........................Brass Sealing Button ................Bronze w/TEFLON Ejection Spring..........Stainless Steel Fusible Element ........Solder, Copper, Stainless Steel Strut .........................Monel Hook..................Bronze/Monel Deflector.....................Bronze Operation A copper tube sealed by two stainless steel balls holds a fusible alloy. When the rated temperature is reached, the alloy melts, the balls are forced to- ward each other releasing the tension mechanism, allowing the sprinkler to operate. Design Criteria The TYCO Series TY-L, 5.6 and 8.0 K- factor, Upright and Pendent Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approv- al agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 20 or 30 Re- cessed Escutcheon, as applicable, are to be used for recessed pendent installations. Installation The TYCO Series TY-L, 5.6 and 8.0 K- factor, Upright and Pendent Sprinklers must be installed in accordance with this section: A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-L Pendent and Upright Sprinkler Installation The Series TY-L Pendent and Upright Sprinklers must be installed in accor- dance with this section. Step 1. Pendent sprinklers are to be installed in the pendent position, and Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 7), ex- cept that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area, or as applicable, the adjustable Crescent wrench is to be applied to the wrenching flanges. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loos- en the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be inspect- ed and the wax coating retouched (repaired) whenever the coating has TFPIIO Page 4 of 6 Frame Sprinkler Finish K Type Temp. Rating Color Natural Chrome Lead Wax Wax Over Code Brass Plated Coated Coated Lead Coated Pendent (TY3211) 165°F (74°C) Unpainted 1, 2, 3 212°F (100°C) White and 1, 2, 3, 5 5.6 ., Upright (TY3111) 280°F (138°C) Blue 1,2 4 N/A NPT Recessed Pendent 165°F (74°C) Unpainted 1, 2, 3, 5 N/A 212°F (100°C) White 1, 2, 3, 5 (TY3211 w/Style 20) 165°F (74°C) Unpainted 1,2,3 212°F (100°C) White Pendent (TY4211) 1, 2, 3 280°F (138°C) Blue 1,2 4 N/A 8.0 165°F (74°C) Unpainted 3/4" 1,2,3 212°F (100°C) White NPT Upright (TY4I11) 1, 2, 3, 5 280°F(138°C) Blue 1,2 4 N/A Recessed Pendent 165° F (74°C) Unpainted 1,2,5 N/A 212°F (100°C) White (TY4211 w/Style 30) Pendent (TY4911) 165°F (74°C) Unpainted 1, 2, 3 212°F (100°C) White and 1, 2, 3, 5 8.0 ., Upright (TY4811) 280°F (138°C) Blue 1, 2 N/A NPT Recessed Pendent 165°F (74°C) Unpainted 1,2 N/A 212°F (100°C) White (1Y4911 w/Style 20) NOTES: UL Listed C-UL Listed FM Approved FM Approved for maximum 150°F (68°C) ambient temperatures LPCB Approved (LPCB Ref. No. 094a/03) N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 in. diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the in- staller from being burned. If attempts to retouch the wax coat- ing with complete coverage are un- successful, additional wax can be or- dered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previ- ously described, touch the rod to the area requiring additional wax with the rod angled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Series TY-L Recessed Pendent Sprinklers Installation The Series TY-L Recessed Pendent Sprinklers must be installed in accor- dance with this section. Step A. After installing the Style 20 or 30 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 10 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 1, 2, or 3, the W-Type 10 Recessed Sprinkler Wrench is to be applied to the sprinkler wrenching flanges. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 or 30 Clo- sure over the Series TY-L Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. TFPIIO Page 5 of 6 A- 7/16±1/8" 2-7/8 DIA. 1/2 (12,7 mm) (11,1±3,2 mm) (73,0 mm) 1/4° (6,4 mm) FACE OF 2-1/4° DIA. MOUNTING SPRINKLER fl (57,2 mm) 1 PLATE FITTING 1/8° (3,2 mm) MOUNTING / SURFACE / 1-3/4" (44,5 mm) 1-1/2" (38,1 mm) CLOSURE TY-L FIGURE 4 SERIES TY-L (TY3211) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 7/16±1/8" 2-7/8" DIA. 1/2(12,7mm) - (11,1±3,2 mm) (73,0 mm) 1/4° (6,4 mm) FACE OF i 2-1/4" DIA. MOUNTING SPRINKLER [ (57,2 mm) 1 _- PLATE FITTING 1/8' (3,2 mm) MOUNTING CLOSURE TYL FIGURE 5 SERIES TY-L (TY4211) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 7/16±1/8" _____ 2-7/8" DIA. .j 1/2(12,7mm) - (11,1±3,2 mm) (73,0 mm) I 1/4"(6,4 mm) I FACE OF 2-1/4 DIA. MOUNTING SPRINKLER (57,2 mm) PLATE I I FITTING 1/8" / (3,2 mm) _/__ MOUNTING 1-3/4" SURFACE (44,5 mm) 1-1/2" (38,1 mm) CLOSURE FIGURE 6 SERIES TY-L (TY4911) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 8.0 K-FACTOR, 1/2 INCH NPT WRENCH RECESS I FIGURE 8 W-TYPE 10 RECESSED SPRINKLER WRENCH Care and Maintenance The TYCO Series TY-L, 5.6 and 8.0 K- factor, Upright and Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over-heated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers -be- fore, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been 111 5.6K UPRIGHT (1/2"NPT) TY3111 112 5.6K PENDENT (1/2"NPT) TY3211 101 8.0K UPRIGHT (3/4'NPT) TY4111 102 8.0K PENDENT (3/4'NPT) TY4211 106 8.0K UPRIGHT (1/2"NPT) TY4811 [107 8.0K PENDENT (1/2"NPT) 1Y4911 I SPRINKLER TEMPERATURE L FINISH RATING 165 165°F (74°C) 212 212-F (100-C) 1 NATURAL BRASS 6 WAX COATED 165°FT0280°FONLY 280 280°F (138°C) 7 LEAD COATED 8 WAX OVER LEAD 165°F TO 212°F ONLY 9 I CHROME PLATED TFPIIO Page 6 of 6 P/N 53 - XXX - X - XXX TABLE B SERIES TV-L PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION completed, to verify the integrity of the corrosion resistant coating. Thereaf- ter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive condi- tions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any oth- er authorities having jurisdiction. The installing contractor or sprinkler man- ufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified In- spection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-L (specify SIN), (specify K-factor), (specify Upright, Pendent, or Recessed Pendent) Sprinkler, Standard Response, Stan- dard Coverage, (specify) temperature rating, (specify) finish or coating, P/N (specify from Table B) Recessed Escutcheon Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify): 1/2" (15 mm) Style 20 Brass Plated.......P/N 56-705-2-010 1/2" (15 mm) Style 20 Signal White (RAL9003) P/N 56-705-4-010 1/2" (15 mm) Style 20 Chrome Plated .....P/N 56-705-9-010 3/4" (20 mm) Style 30 Brass Plated.......P/N 56-705-2-011 3/4" (20 mm) Style 30 Signal White (RAL9003) P/N 56-705-4-011 3/4" (20 mm) Style 30 Chrome Plated .....P/N 56-705-9-011 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify: W-Type 10 Sprinkler Wrench, P/N 56-000-1-948 Wax Sticks (for retouching wrench damaged wax coating) Specify: Series TY-L Sprinklers, (specify color), color coded Wax Stick for retouching, (specify) temperature rated, P/N (specify): Red for 165°F (74°C) . . P/N 56-065-1-155 Blue for 212°F (100°C) and 280°F (138°C) P/N 56-065-1-286 NOTES: Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 280°F (138°C) sprin- klers is the same as for 212°F (100°C) sprinklers, and, therefore, the 280°F (138°C) sprinkler is limited to the same maximum ceiling temperature as the 212°F (100°C) sprinkler (i.e., 150°F (65°C)). GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation Fire Protection Products