HomeMy WebLinkAbout2622 GATEWAY RD; 115; FPC2019-0009; PermitPERMIT REPORT Cd-risbad 4c7city of Print Date: 03/02/2022 Permit No: FPC2019-0009 Job Address: 2622 GATEWAY RD, # 115, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132621900 Track #: Applied: 01/16/2019 Valuation: $159,901.38 Lot #: Issued: 01/28/2019 Occupancy Group: Project #: Finaled Close Out: 05/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: KBS GOLF SHAFTS -SPRINKLER TI (33 HEADS) Applicant: FPContractor: SCHMIDT FIRE PROTECTION CO INC SCHMIDT FIRE PROTECTION CO INC JASON ALVA 4760 MURPHY CANYON RD 4760 MURPHY CANYON RD SAN DIEGO, CA 92123-4321 SAN DIEGO, CA 92123-4321 (858) 279-6122 (858) 279-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Bulletin 013 Rev. N Reliable Models Fl Series Standard Response Sprinklers PIA Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl 56 Recessed Sprinkler Types Pendent/F1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1 325) 0786-C PD-40254 (RA1 375) UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Recessed XLH Upright Horizontal Sidewall Pendent/FP ham XLH Pendent XLH Recessed Pendent F1/F2 Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 1JFGO4 Model F142, F1XLH Upright Technical data: Models Nominal K-Factor Response Thread Max. Working Mm. Working Temperature Finish Size Pressure Pressure Rating F156 5.6 (80 Metric) ½" NPT See See F142 F1XLH 4.2 (60 Metric) Standard (R½) 175 PSI 1 7 PSI Temperature Finish Table" Ratings" Table F128 2.8 (40 Metric) Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or or coated with PTFE Adhesive Glass CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape (1) Model F156 upright, pendent, and recessed pendent sprinklers (SIN RA1325 and RA1314) are cULus Listed for 250 psi (17 bar). 2. Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor ______________ Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) USI Metric Upright I Pendent __________________________ Standard -Upright (SSU) and 'endent Deflectors Marked to Indicate Position ½' (15mm) (1) ½" N P T (R½) 5.6 80 2.25" (57mm) 1, 2, 3,4, 5 RA1314 3 7/16"(lomm) ½" NPT(R½) 4.2 60 2.25" (57mm) 1 RA132326 RA13136 3/8"(10mm) ½" NPT(R½) 2.8 40 2.25(57mm) 1 RA132126 RA13116 Conventional-Install in Upright or Pendent Position 15mm" I ½" N P T (R½) I 5.6 I 80 I 57mm 1 3. 4, 5 1 RA13755 Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. ----- Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. Electroless Nickel PTFE Plated - UL listed Corrosion Resistant Upright Pendent Conventional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers 1 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric ½" (15mm) ½" NPT (R½) 5.6 80 2.25" (57mm) RA13142 /16 (10mm) ½" N P T (R½) 4.2 60 2.25" (57mm) RA13132 /" (10mm) ½" NPT(R½) 2.8 40 2.25" (57mm) RA1311 2 Refer to escutcheon data table for approvals & dimensions Electroless Nickel FIFE Plated - cULus listed Corrosion Resistant 2/4 IDLE DIN [5T2NLNJ 75/76' 02 L-.AXVE=±=UH-UI-S-I . 7/0' REOIIDFR TURN CRLLAP 0061 ROOT A-, _ER OF FITTING - I j TO FACE OF CEILRIG DIMENSION FT ESCUTChEON AT MAXIMUM RECESS 172S-] A , MINIMUM RECESS J18TY.5-1 Zf TA j/4TI-1 ADJUSTMENT _j (lII4Jl k) AT MINIMUM RECESS - '1 ADJUSTMENT RECESS 1/8 122 21, AT -MUM RECESS 1- 1187286-1 AT —UA RECESS 2 77112'- RECESSED PENDENT W/F1 OR F2 ESCUTCHEON -SPRINKLER NOT FM APPROVED WITH F7 ESCUTCHEON Model F156, F142, F1XLH & F128 F-i or -2 5/8' 014 [o67.....] - If ------------X 7/2' REDUCER I I HOLE IN CEILING I / CEILING FACE OF FITTING 2 5/TUT 814. [587......] - CUP I TO FACE OF CEILING DIMENSION dA T MAXIMUM RECESS - T-T/2'[38..NT.] T MINIMUM RECESS = T[25.467#] MAXIMUM RECESS - 9/767T4.3.] FO[50.8IT,n] ADJUSTMENT 3 7/4' DA. AT MINIMUM RECESS - T'[2S4RTRTJ [826'.'..] - RECESSED PENDENT W/FP ESCUTCHEON 07470026 SPRINKLER NOT FM APPROVED WITH PP ESCUTCHEON Model F156, F142, F1XLH & F128 FP 3. Vertical Sidewall Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Nominal Orifice I Thread Size I Nominal K Factor Sprinkler I Height Approval Organizations I Sprinkler Identification US I Metric Numbers (SIN) 1/2" (15mm) ½" NPT (R½) 5.6 80 2.25" (57mm) 1, 2, 3 RA1385(I2I(3)(4) LPC Approval is pendent only, 57°C through 14 1°C ratings. cULus Listed corrosion resistant (Polyester coated) sprinkler. cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW (I) I 15/l6 oIA..c,.L.4 I 4"-I2 2 27/32 DIA. [101.6r,,m-304.8,,,m] CEILING TO II [722,,,,,,] DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON 3/4779mm] ADJUSTMENT F2 ESCUTCHEON 7/2772.7mm] ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (I) FM APPROVED FOR 4 - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = I "[25.4mg,] AT MINIMUM RECESS = 3/8[9.5,,,m] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19,,,] AT MINIMUM RECESS = 3/8[9.5nr] 1-2 1/4 HOLE DIA. [57.2,] IX 1/2 REDUCER Fl ESCUTCHEON AT MAXIMUM RECESS 1-3/8T34.9,,v,,] AT MINIMUM RECESS = 2-l/I6"[52,4m,,] V F2 ESCUTCHEON I AT MAXIMUM RECESS = I-5/8'4l.3r,,] AT MINIMUM RECESS = 2-1116 , T52.4-1 I Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with Fl or F2 escutcheons for "Light Hazard" only. Installation Wrench: Model 0 Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data:Horizontal Sidewall Nominal K Factor __________________ Sprinkler Height Approval Organizations Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 1 cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. Polyester coated FM approved sprinkler. > Electroless Nickel PTFE Plated - cULus listed Corrosion Resis:ant 4. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color Oc OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High" 141 286 225°F (107°C) Blue Extra High" 182 360 300°F (149°C) Mauve Ultra High (1)(2) 260 500 1 475°F (2460c) Black Not available for recessed Sprinklers. cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) SIN RA1325 & RA1314 cULus listed for 250 psi (17 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finish1 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated )6)(7))9) White Painted Special Application Finishes Sprinkler Escutcheon Electroless Nickel PTFE(3X10) Electroless Nickel PTFE Bright Brass2 Bright Brass Black Plated Black Plated Black Paint39 Black Paint Off White (3)(9) Off White Chrome Dull Chrome Dull Lead Wax Wax Over Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. 2 200°F (93°C) maximum. UL and ULC listed only 4 155°F to 200°F (68°C to 93°C) ratings only. 5>286°F (141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). cULus listed corrosion resistant" applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1 321 (Upright), RA1335 (HSV, RA1385(VS and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approved finish as "Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. FM Approved finish applies only to SIN number RA1335 & RA1385. LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. ('())cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313 ,R.A1321, RA1311, RA1385 and RA1335 ,1 Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & F128 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry Deluge or Preacflon. Care must exercised that the orifice size, temperature rang, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Junsdic- on Installation. Installation Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA I 13. They must also be installed with the Model D Sprinkler Wrench or Model W2 Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model Fl, F2, and F Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon Will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight ½" NPT (R½) sprinkler joint can be obtained with a torque of 8- 18 ft-lbs (11 -24 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impair- ment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Nominal K-Factor Temperature Rating Sprinkler Finish Thread Type: [½" NPT] [ISO 7-1R½] Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (1) SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only 5. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper Reliabld (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. (800) 848-6051 Sales Fax www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/17 P/N 9999970299