HomeMy WebLinkAbout2622 GATEWAY RD; 115; FPC2019-0009; PermitPERMIT REPORT Cd-risbad
4c7city of
Print Date: 03/02/2022 Permit No: FPC2019-0009
Job Address: 2622 GATEWAY RD, # 115, CARLSBAD, CA 92009 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2132621900 Track #: Applied: 01/16/2019
Valuation: $159,901.38 Lot #: Issued: 01/28/2019
Occupancy Group: Project #: Finaled Close Out: 05/25/2021
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check#: Final Inspection:
Project Title:
Description: KBS GOLF SHAFTS -SPRINKLER TI (33 HEADS)
Applicant: FPContractor:
SCHMIDT FIRE PROTECTION CO INC SCHMIDT FIRE PROTECTION CO INC
JASON ALVA 4760 MURPHY CANYON RD
4760 MURPHY CANYON RD SAN DIEGO, CA 92123-4321
SAN DIEGO, CA 92123-4321 (858) 279-6122
(858) 279-6122
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov
Bulletin 013 Rev. N
Reliable Models Fl Series
Standard Response
Sprinklers
PIA
Model F156 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
Model Fl 56 Recessed Sprinkler Types
Pendent/F1/F2/FP
Horizontal Sidewall
Model F142, F1XLH & F128 Sprinkler Types
Standard Upright
Standard Pendent
Model F142, F1XLH & F128 Recessed Sprinkler
Types
Pendent/F1/F2/FP
Approval Organizations
Underwriters Laboratories Inc. and certified for
Canada (cULus)
Factory Mutual Approvals (FM)
Loss Prevention Council (LPCB, UK)
VdS SchadenverhUtung GmbH
EC Certificate: 0786-CPD-40237 (RA1314)
0786-CPD-40253 (RA1 325)
0786-C PD-40254 (RA1 375)
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Product Description
The F156, F142, F1XLH & F128 Series Glass Bulb
Sprinkler combines the durability of a standard sprinkler
with the attractive low profile of a decorative sprinkler.
Whether installed on exposed piping or in an office ceil-
ing, it is functional and attractive.
Beautifully versatile is the description for the Reliable
Models F156, F142, F1XLH & F128 Series Recessed
glass bulb sprinkler. Recessing the F156, F142, F1XLH &
F128 Series enhances its already low profile decorative
appearance, and facilitates a rapid and perfect installa-
tion.
The recessed escutcheon of the Models F156, F142,
F1XLH & F128 are highly adjustable. The two piece con-
struction makes field installation a very easy and rapid
task. This also allows ceiling panels to later be removed
without shutting down the fire protection system, thus fa-
cilitating maintenance of above ceiling services.
Upright Pendent Conventional
Vertical Sidewall Horizontal Sidewall Recessed
Pendent/F1/F2
Recessed Recessed XLH Upright
Horizontal Sidewall Pendent/FP
ham
XLH Pendent XLH Recessed
Pendent F1/F2 Pendent FP
The F156, F142, F1XLH & F128 Series Automatic Sprin-
kler utilizes a 5.0 mm frangible glass bulb. The glass bulb
consists of an accurately controlled amount of special
fluid hermetically sealed inside a precisely manufactured
glass capsule. This glass bulb is specially constructed to
provide fast thermal response.
At normal temperatures, the glass bulb contains the
fluid in both the liquid phase and in the vapor phase. The
vapor phase can be seen as a small bubble. As heat is
applied, the liquid expands forcing the bubble smaller
and smaller as the liquid pressure increases. Continued
heating forces the liquid to push out against the bulb,
causing the glass to shatter, opening the waterway and
allowing the deflector to distribute the discharging water.
The F156, F142, F1XLH & F128 Series Sprinkler tem-
perature rating is identified by the color of the glass bulb
capsule as well as frame color where applicable.
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Pin tie
(XLH Only)
Deflector
Load Screw
Washer
Bulb
Frame
Cup
0 1JFGO4
Model F142, F1XLH Upright
Technical data:
Models Nominal K-Factor Response Thread Max.
Working
Mm.
Working Temperature Finish Size Pressure Pressure Rating
F156 5.6 (80 Metric)
½" NPT See See F142
F1XLH 4.2 (60 Metric) Standard (R½) 175 PSI 1 7 PSI Temperature Finish Table" Ratings" Table
F128 2.8 (40 Metric)
Material Data:
Frame Deflector Load Screw Pintle Cup Washer Bulb
DZR Brass
CDA Alloy 260,
CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360
QM Brass or or or or coated with PTFE Adhesive Glass
CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
(1) Model F156 upright, pendent, and recessed pendent sprinklers (SIN RA1325 and RA1314) are cULus Listed for 250
psi (17 bar).
2.
Model F156, Upright, Pendent & Conventional Sprinklers
Model F142, F1XLH & F128 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
Nominal K-Factor
______________
Sprinkler
Height
Approval
Organization
Sprinkler Identification Number
(SIN)
USI Metric Upright I Pendent __________________________
Standard -Upright (SSU) and 'endent Deflectors Marked to Indicate Position
½' (15mm) (1) ½" N P T (R½) 5.6 80 2.25" (57mm) 1, 2, 3,4, 5 RA1314 3
7/16"(lomm) ½" NPT(R½) 4.2 60 2.25" (57mm) 1 RA132326 RA13136
3/8"(10mm) ½" NPT(R½) 2.8 40 2.25(57mm) 1 RA132126 RA13116
Conventional-Install in Upright or Pendent Position
15mm" I ½" N P T (R½) I 5.6 I 80 I 57mm 1 3. 4, 5 1 RA13755
Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56)
cULus Listed corrosion resistant (Polyester coated) sprinkler.
Polyester coated FM Approved sprinkler.
-----
Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375.
Electroless Nickel PTFE Plated - UL listed Corrosion Resistant
Upright Pendent Conventional
Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers 1
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
Nominal K-Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
½" (15mm) ½" NPT (R½) 5.6 80 2.25" (57mm) RA13142
/16 (10mm) ½" N P T (R½) 4.2 60 2.25" (57mm) RA13132
/" (10mm) ½" NPT(R½) 2.8 40 2.25" (57mm) RA1311 2
Refer to escutcheon data table for approvals & dimensions
Electroless Nickel FIFE Plated - cULus listed Corrosion Resistant
2/4 IDLE DIN [5T2NLNJ
75/76' 02
L-.AXVE=±=UH-UI-S-I
. 7/0' REOIIDFR
TURN CRLLAP 0061 ROOT A-, _ER OF FITTING
- I j
TO FACE OF CEILRIG DIMENSION
FT ESCUTChEON AT MAXIMUM RECESS 172S-]
A , MINIMUM RECESS J18TY.5-1
Zf TA j/4TI-1
ADJUSTMENT _j (lII4Jl k) AT MINIMUM RECESS -
'1 ADJUSTMENT RECESS 1/8 122 21,
AT -MUM RECESS 1- 1187286-1 AT —UA RECESS
2 77112'-
RECESSED PENDENT W/F1 OR F2 ESCUTCHEON
-SPRINKLER NOT FM APPROVED WITH F7 ESCUTCHEON
Model F156, F142, F1XLH & F128 F-i or -2
5/8' 014 [o67.....] - If ------------X 7/2' REDUCER
I I HOLE IN CEILING
I /
CEILING
FACE OF FITTING
2 5/TUT 814. [587......] - CUP
I TO FACE OF CEILING
DIMENSION
dA
T MAXIMUM RECESS - T-T/2'[38..NT.]
T MINIMUM RECESS = T[25.467#]
MAXIMUM RECESS - 9/767T4.3.]
FO[50.8IT,n]
ADJUSTMENT
3 7/4' DA.
AT MINIMUM RECESS - T'[2S4RTRTJ
[826'.'..] -
RECESSED PENDENT W/FP ESCUTCHEON 07470026
SPRINKLER NOT FM APPROVED WITH PP ESCUTCHEON
Model F156, F142, F1XLH & F128 FP
3.
Vertical Sidewall
Model F156 Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench or
Model W2 Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
U.S. Patent No. 6,374,920
Sprinkler Type Deflector to Ceiling Distance
(Min. - Max.)
Upright 4" (102mm) - 12" (305mm)
Pendent 4" (102mm) - 12" (305mm)
Installation Data:
Nominal
Orifice
I
Thread Size I
Nominal K Factor Sprinkler
I Height
Approval
Organizations
I Sprinkler
Identification US
I
Metric Numbers (SIN)
1/2" (15mm) ½" NPT (R½) 5.6 80 2.25" (57mm) 1, 2, 3 RA1385(I2I(3)(4)
LPC Approval is pendent only, 57°C through 14 1°C ratings.
cULus Listed corrosion resistant (Polyester coated) sprinkler.
cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead.
Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant
Model F156 Horizontal Sidewall Sprinkler
Deflector: HSW
(I) I
15/l6 oIA..c,.L.4 I 4"-I2
2 27/32 DIA. [101.6r,,m-304.8,,,m]
CEILING TO
II
[722,,,,,,] DEFLECTOR
TURN COLLAR UNTIL
TIGHT AGAINST SPRINKLER
WRENCH BOSS. Fl ESCUTCHEON
3/4779mm] ADJUSTMENT
F2 ESCUTCHEON
7/2772.7mm] ADJUSTMENT
RECESSED HSW W/F1 OR F2 ESCUTCHEON
(I) FM APPROVED FOR 4 - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR.
FACE OF FITTING
TO FACE OF CEILING DIMENSION
Fl ESCUTCHEON
AT MAXIMUM RECESS = I "[25.4mg,]
AT MINIMUM RECESS = 3/8[9.5,,,m]
F2 ESCUTCHEON
AT MAXIMUM RECESS = 3/4"[19,,,]
AT MINIMUM RECESS = 3/8[9.5nr]
1-2 1/4 HOLE DIA.
[57.2,]
IX 1/2 REDUCER
Fl ESCUTCHEON
AT MAXIMUM RECESS 1-3/8T34.9,,v,,]
AT MINIMUM RECESS = 2-l/I6"[52,4m,,] V F2 ESCUTCHEON
I AT MAXIMUM RECESS = I-5/8'4l.3r,,]
AT MINIMUM RECESS = 2-1116 , T52.4-1
I
Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2.
FM and cULus permits use with Fl or F2 escutcheons for
"Light Hazard" only.
Installation Wrench: Model 0 Sprinkler Wrench or Model W2 Sprinkler Wrench
Installation Data:Horizontal Sidewall
Nominal K Factor
__________________
Sprinkler
Height Approval Organizations Sprinkler
Nominal Orifice Thread Size Identification
US Metric Light Hazard Ordinary Numbers (SIN) Hazard
½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1
1 cULus Listed corrosion resistant (Polyester coated) sprinkler.
(2) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead.
Polyester coated FM approved sprinkler.
> Electroless Nickel PTFE Plated - cULus listed Corrosion Resis:ant
4.
Maintenance
The Model F156, F142, F1XLH & Model F156, F142, F1X-
LH & F128 Recessed Sprinklers should be inspected and
the sprinkler system maintained in accordance with NFPA
25. Do not clean sprinklers with soap and water, ammonia
or any other cleaning fluid. Replace any sprinkler which has
been painted (other than factory applied) or damaged in
any way. A stock of spare sprinklers should be maintained
to allow quick replacement of damaged or operated sprin-
klers. Prior to installation, sprinklers should be maintained
in the original cartons and packaging until used to minimize
the potential for damage to sprinklers that would cause im-
proper operation or non-operation.
Temperature Ratings
Classification
Sprinkler
Temperature Max. Ambient
Temp.
Bulb
Color Oc OF
Ordinary 57 135 100°F (38°C) Orange
Ordinary 68 155 100°F (38°C) Red
Intermediate 79 175 150°F (66°C) Yellow
Intermediate 93 200 150°F (66°C) Green
High" 141 286 225°F (107°C) Blue
Extra High" 182 360 300°F (149°C) Mauve
Ultra High (1)(2) 260 500 1 475°F (2460c) Black
Not available for recessed Sprinklers.
cULus listed for SIN RA1325 and RA1314 only.
Maximum Working Pressure
175 psi (12 bar)
SIN RA1325 & RA1314 cULus listed for 250 psi (17 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Finish1
Standard Finishes
Sprinkler Escutcheon
Bronze Brass
Chrome Chrome
Polyester Coated )6)(7))9) White Painted
Special Application Finishes
Sprinkler Escutcheon
Electroless Nickel PTFE(3X10) Electroless Nickel PTFE
Bright Brass2 Bright Brass
Black Plated Black Plated
Black Paint39 Black Paint
Off White (3)(9) Off White
Chrome Dull Chrome Dull
Lead
Wax
Wax Over
Other colors and finishes are available on special order. Consult factory for
details. Custom color painted sprinklers may not retain their UL Corrosion
resistance listing.
2 200°F (93°C) maximum.
UL and ULC listed only
4 155°F to 200°F (68°C to 93°C) ratings only.
5>286°F (141°C) sprinklers may be coated for ambient conditions not exceeding
150°F (66°C).
cULus listed corrosion resistant" applies to SIN Number RA1325 (Upright)
RA1323 (upright), RA1 321 (Upright), RA1335 (HSV, RA1385(VS and
RA1314 (Pendent) in standard black or white. Corrosion resistance in other
polyester colors is available upon request.
FM Approved finish as "Polyester Coated" applies to SIN number RA1314,
RA1335 & RA1325 in standard black or white.
FM Approved finish applies only to SIN number RA1335 & RA1385.
LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375.
('())cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323,
RA1313 ,R.A1321, RA1311, RA1385 and RA1335
,1
Application
Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH &
F128 Recessed sprinklers are used in fixed fire protection systems:
Wet, Dry Deluge or Preacflon. Care must exercised that the orifice
size, temperature rang, deflector style and sprinkler type are in ac-
cordance with the latest published standards of the National Fire
Protection Association or the approving Authority Having Junsdic-
on Installation.
Installation
Model F156, F142, F1XLH & F128 Series sprinklers are standard
response sprinklers intended for installation as specified in NFPA
I 13. They must also be installed with the Model D Sprinkler Wrench
or Model W2 Sprinkler Wrench specifically designed by Reliable
for use with these sprinklers.
The Model F156, F142, F1XLH & F128 Recessed Sprinklers
are to be installed with a maximum recess of 3/4 inch (19mm). The
Model Fl, F2, and F Escutcheon illustrated are the only recessed
escutcheon to be used with the Model F156, F142, F1XLH & F128
Recessed Sprinklers. The use of any other recessed escutcheon
Will void all approvals and negate all warranties. When installing
Model F156, F142, F1XLH & F128 Recessed Sprinklers use the
Model GFR2 Sprinkler Wrench. Any other type of wrench may
damage these sprinklers.
Note: A leak tight ½" NPT (R½) sprinkler joint can be obtained with
a torque of 8- 18 ft-lbs (11 -24 N-m). Do not tighten sprinklers over
maximum recommended torque. It may cause leakage or impair-
ment of the sprinklers.
Glass bulb sprinklers have orange covers to protect the bulb dur-
ing the installation process. REMOVE THIS PROTECTION ONLY
AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED
AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN
INSTALLED. RASCO wrenches are designed to install sprinklers
when covers are in place.
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Nominal K-Factor
Temperature Rating
Sprinkler Finish
Thread Type: [½" NPT] [ISO 7-1R½]
Escutcheon Finish (where applicable)
Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers
are ordered, the sprinklers and escutcheons are packaged separately.
Escutcheon Data (1)
(1) SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light
hazard only
5.
Reliable...For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Automatic sprinklers
Flush automatic sprinklers
Recessed automatic sprinklers
Concealed automatic sprinklers
Adjustable automatic sprinklers
Dry automatic sprinklers
Intermediate level sprinklers
Open sprinklers
Spray nozzles
Alarm valves
Retarding chambers
Dry pipe valves
Accelerators for dry pipe valves
Mechanical sprinkler alarms
Electrical sprinkler alarm switches
Water flow detectors
Deluge valves
Detector check valves
Check valves
Electrical system
Sprinkler emergency cabinets
Sprinkler wrenches
Sprinkler escutcheons and guards
Inspectors test connections
Sight drains
Ball drips and drum drips
Control valve seals
Air maintenance devices
Air compressors
Pressure gauges
Identification signs
Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years.
Manufactured by
Reliable Automatic Sprinkler Co., Inc. Recycled
(800) 431-1588 Sales Offices Paper Reliabld (914) 829-2042 Corporate Offices Revision lines indicate updated or new data.
(800) 848-6051 Sales Fax
www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/17 P/N 9999970299