Loading...
HomeMy WebLinkAbout1896 RUTHERFORD RD; ; FPC2016-0002; Permit(city of Carlsbad Print Date: 03/21/2022 Permit No: FPC2016-0002 Job Address: 1896 RUTHERFORD RD, CARLSBAD, CA 92008-7326 Status: Closed - Finaled Permit-Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 11/08/2016 Valuation: $0.00 Lot #: Issued: 11/21/2016 Occupancy Group: Project #: Finaled Close Out: 03/14/2017 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: INSTALLATION OF NEW CELL COMMUNICATOR TO MONITOR EXISTING FACP Applicant: M AND B ELECTRIC INC 14460 KENTFIELD PL POWAY, CA 92064-3361-SAN DIEGO (858) 668-2803 FEE AMOUNT Fire Inspection Fee Manual $156.00 Fire Protection Sys Manual $175.00 Total Fees: $331.00 Total Payments To Date: $331.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 760-602-8561 f I www.carlsbadca.gov I From Tyco Security Products FPC20I6-0002 1896 Rutherford RD 3G technology from DSC! Features That Make a Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IP receiver Automatically switches to 2G (EDGEIGPRS) if 30 service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via automated telephone activation system (VRU), web-user or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard System l-IP/II/III/IV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed The 3G4010CF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-lP/lVlll/IV/5). The 3G401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The 3G4010CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 and 2013 Editions. It can be used in Fire Monitoring applications as a single communications technology,, n which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or, 1 hour (NFPA72 2013) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G401OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G4O1OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. In instances where the control panel does not support Contact ID or SIA (300 baud), the 3G401OCF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard® System I -I Pill/Ill/i V/5). From Tyco Security Products Activating & Initializing the Unit Activating and initializing the 3G4010CF can be done using the automated telephone activation system (VRU), mobile interface or web-user interlace provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The 3G4010CF is UL listed under File 54019, Usting guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the 3G401OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G40100F will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G401OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G401OCF has been approved by the California State Are Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G4O1OCF-USA .......... Universal Wireless Commercial Are IJarrn Communicator (U.S. ModeVSlM Card Included) Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the 3G401OCF requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2 x 10' x3' (290 mm x 254 mm x 75 mm) InputVoltage.............................................................120 VAC Current Draw ............................................... 200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (00 to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description GS-1 5ANT 15 ft extension antenna (internal use) GS-25ANT 25 ft extension antenna (internal/external use) GS-50ANT 50 ft extension antenna (internal/external use) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0161 Page 1 of 1 CATEGORY: p7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model 3G4010CF RF Communicator (GSM-GPRS/3G) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 V, 50/60 Hz, 0.3 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 06-03-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 ListingExpires :June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Remote Diagnostics Panel Format Detection SMS Command and Control Phone number call direction Easy enrollment with C24 Communications via VRU, web or mobile interface NOTE: The 3G4010CF is designed to work with the Contact ID communication format as described in SIA DC-05 Standard or the SIA communication format as described in SIA DC-03 Standard. Before completing the field installation of the alarm mon- itoring system, please ensure communication with the supervising station is successful by sending several events and con- firming that they have been received. Technical Specifications Ratings Power Supply Ratings Input Voltage: 120 V/60HzJ0.3A Standby Voltage: 12V17AH Standby Time: 24h (NSC) plus 5 minutes alarm Low Battery Trouble Indication Threshold: 11.5 VDC Battery Deep Discharge Protection (cut-off): 9.5VDC Battery Type: sealed, rechargeable type, rated 12V/7Ah (for 24hr standby time) Battery charging voltage: 13.75 Vdc Battery charge current 700mA (maximum) NOTE: Battery must be replaced every 3-5 years. Operating frequency - 2G (GSM/GPRSIEDGE): 850/1900MHz Operating frequency - 3G (UMTSIHSPA): 850/1900MHz Antenna gain: 2.0dBi Environmental Specifications Operating temperature: 0°C49°C (32°F-i 20°F) Humidity. 93%RH Maximum (non-condensing) Mechanical Specifications Endosure Type metal, red, hardwired transformer and high voltage connection box included Endosure Dimensions: 290mm x 254mm x 75mm (11.5"x 1 0° x 3") Weight 5.8Kg (12.8 Ibs) (including standby battery) Simulated Telco Loop specifications (TIP/RING) On-Hook Voltage: 12Vdc Off-Hook Voltage (Maximum): 22Vdc Loop Current: 25mA Loop Resistance: 600 Ohms Standard Battery Capacity The calculation for battery capacity is based on 200mA standby current for 24 hours plus a five minute alarm at 400mA or 600mA (if the 4 PGM outputs are also activated) The requirements are as follows: 200mA x 24h = 4800mAh capadty for standby 400mA x5/60h 33.33mAh capacity for alarm condition Total = 4833.33 mAh needed for 24h and five minutes alarm transmission. The supplied battery is W. 4 2co?O)I SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time ofsystem acceptance and approvaL It shall be permitted to modify thisform as needed to provide a more complete and/or clear record Insert NM in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: Supplemental Pages Attached: I. PROPERTY INFORMATION Name of property; Address: M Description of property- .- Name of property representative: (Vtttt 5 ' Address: S c 6 i- F Phone: (,(4 4) Fax: E-mail: llc.1t A ' ptp INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Address: I 4'4O Phone: Fax: E-mail: Service organ zatiorn L Address: ç i01s4 /A %i t ( Phone: 11 —( I -5Qu Fax: E-mail: a kirv'-i IQq I Testing .organization: Address: Phone: Fax: Effective date for test and inspection contract 1 1 c Ic Monitoring organization: rt Address:. %tP MY,o JO Phone: fl I Fax: E-maiF Accountnumber , Phone line 1: Phoneline2: I Means of transmission I)SL. 45o1 Entity to to which alarms are retransmitte& f)L.4e.L ((..d. Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system Modificafionto existing system Pemitnumber NFPA 72 edition: - 4.1 Control Unit Manufacturer: Model number: )I 0f 4.2 Software and Firmware Firmware revision number: 43 Alarm Verification N This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright § 2012 National Fire Protection Assodation. This form may be copied for- indhtdu5l use other than for resale. It may not be copied for comroprrial sate or rsVibuton. (p.1 of 2) SYSTEM RECORD OF COMPLETION (continued) S. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: U ( - Control panel amps: 6 t4) Overcunent protection: Type: c + ()t€st Amps: 1 Branch circuit disconnecting means location: QML Number: 5.1.2 Secondary Power Type of secondary power. Location, if remote from .the plant: Calculated capacity of secondary power to chive the system: In standby mode (hours):. 5.2 Control Unit This system does not have power extender panels [j Power extender panels are listed on supplementary sheet A In alarm mode (minutes): b. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Linc Device Power Initiating Device Notification Appliance Other (specify): - REMOTE ANN Location INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations t Smoke Detectors Duct Smoke Detectors - WA fti/t HeatDetectors ___NA _______ Gas Detectors M /\ - N A Waterfiow Switches _________ Tamper Switches __ copyilqhte 2012 Naijonal Fire Proteclion Assodation. This form maybe onpied forindtedual use other than for resale. It may not be copied for commerdal sale or distribution. (p. 2 of 2) AHJ representative: SYSTEM RECORD OF COMPLETION (con tlnued) 0 Mt%TIItATIfltJ SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip INTERCONNECTED SYSTEMS This system does not have interconnected systems. 0 Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 121 System Installation Contractor This system as speied herein has been installed according to all NFPA standards cited herein. Signed: Printed name: ()4 Date: Organization: Title: z) L._ Phone: 122 System 0 eratlonal Test This system as'fled herein has tested according to all NFPA standards cited herein. Signed: Printed name: ('A4 Date: Organization: tIvu- 0 Title: Phone: 12.3 Acceptance Test Date and time of acceptance test: I I 3D? (•\ Installing contractor representative: Testing contractor representative: Property representative: iot'? L1)s4ç Copyright @2012 National Pim protection Association. This form may be copied for iridhadual use other than for resale. It may not be copied for commercial sale or distilbulion. - (p.30f3)