Loading...
HomeMy WebLinkAbout2310 CAMINO VIDA ROBLE; ; AS120021; PermitCity of Carlsbad Sprinkler Permit Permit No: AS120021 2310 CAMINO VIDA Job Address: Status: PENDING ROBLE Permit Type: SPRINK Applied 2/21/2012 Parcel No: 2130500800 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: NORTH COAST CHURCH T.I. Applicant: CPS FIRE PROTECTION, INC. 417 VERNON WY EL CAJON, CA 19-590-1101 Owner: R J VIDA ROBLE INVESTORS L L C 2333 STATE ST #200 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 262 0 262 0 AS12-0024 800-381-9312 Technical Services +1-401-781-8220 www.tyco-fire.com Series EC-11 & EC-14 - 112 and 140 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers General Description The TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (for example, NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 1(20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli- cation listing for use under concrete tees. The Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin- klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers passed standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity should be consid- ered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any author- ities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. FEBRUARY 2012 Sprinkler Identification Numbers (SINs) TY5137 - Upright, 11.2K 1Y5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and S2510. TY5237 is a redesignation for 05237, G1893, and S2511. 1Y6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. TFP22O CROSS PENDENT SECTION TFP22O Page 2 of 8 - Frame 2- Button 3-Sealing Assembly 4-Bulb 5-Compression Screw 6-Deflector * Temperature rating is indicated on deflector ** Pipe thread connections per ISO 7/1 can be provided on special request. WRENCH 3/4 ESCUTCHEON PLATE FLAT NPT** SEATING SURFACE 2-7/16 (61,9 mm) UPRIGHT & PENDENT I- 1/2"(12,7 mm) NOMINAL MAKE-IN UPRIGHT FIGURE 1 SERIES EC-1 I AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) - ASSEMBLY - Hazard Type Temperature Bulb Liquid Sprinkler Finish (See Note 5) Natural I Chrome I White* I Lead Brass Plated Polyester Coated Upright K=11.2 (TY5137) 135°F (57°C) Orange 1, 2, 3**, 4 155°F (68°C) Red 175°F (79°C) Yellow Light Pendent Refer to Table B for UL and C-UL K=11.2 (1Y5237) K=14. 0 (TY6237) 200°F (93°C) Green 1, 2, 4 1, 2, 4 286°F (141°C) Blue Recessed Pendent K11.2 (TY5237) K=14.0 (TY6237) With Style 30 Escutcheon 135°F (57°C) Orange 1.2,3,4 1, 2, 4 N/A Sensitivity Rating Refer to Table C for FM Sensitivity Rating 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Ordinary Refer to Table B for UL and C-UL Sensitivity Rating Refer to Table C for FM Sensitivity Rating Upright K11.2 (TY5137) K=14.0 (TY6137) Pendent K=11.2 (TY5237) K=14.0 (TY6237) 135°F (57°C) - Orange 1, 2, 3. 4 1, 2.3,4 155°F (68°C) --- Red 175°F (79°C) Yellow 1, 2, 4 200°F (93°C) Green 286°F(141°C) Blue Recessed Pendent K°r11.2 (TY5237) K14.0 (TY6237) With Style 40 135°F (57°C) Orange 1, 2, 4 N/A 155°F (68°C) Red 175°F (79°C) Yellow Escutcheon 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc. (UL) 5. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Cor- Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) rosion Resistant Sprinklers Approved by Factory Mutual Research Corporation (FM) * Frame and Deflector only. Listings and approvals apply to color Approved by the City of New York under MEA 177-03- E (Special Order) ** Pendent Only N/A: Not Available TABLE A - LABORATORY LISTINGS AND APPROVALS - TFP22O Page 3 of 8 Light Hazard Ordinary Hazard Area Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - OR OR OR OR SR 14 x 14 Style 30 Recessed - - - - - OR OR OR OR N/A Style 40 Recessed - - - - - OR OR OR OR N/A Upright or Pendent OR' OR' OR' OR° OR' SR SR SR SR SR 16 x 16 Style 30 Recessed OR' OR' OR' OR' OR' SR SR SR SR N/A Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A Upright or Pendent OR' OR° OR' OR' OR' SR SR SR SR SR 18 x 18 Style 30 Recessed OR' OR' OR' OR' OR' SR SR SR SR N/A Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A Upright or Pendent OR' OR' OR' SR* SR* SR SR SR SR SR 20 x 20 Style 30 Recessed OR° OR* OR' SR* SR' SR SR SR SR N/A Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A OR: Quick Response SR: Standard Response N/A: Not Applicable 'Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-li OR EC-14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) Light Hazard Ordinary Hazard Area Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A Style 40 Recessed - - - - - N/A N/A N/A N/A N/A Upright or Pendent OR' OR N/A N/A N/A SR SR SR SR SR 16x16 Style 30 Recessed OR OR' N/A N/A N/A N/A N/A N/A N/A N/A Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Upright or Pendent OR' OR' N/A N/A N/A SR SR SR SR SR 18x18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Upright or Pendent OR' OR N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K=14.0 TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-Il OR EC-14 SPRINKLERS (Refer to FM Loss Prevention Data Sheet 2-8N for Permitted K-Factor/Area Combinations) TFP22O Page 4 of 8 Technical Data Approvals Refer to Table A for approval information on the TYCO Series EC-11 and EC-14 Sprinklers, as well as the TYCO Style 30 and Style 40 Two-Piece Recessed Escutcheons. The approvals apply to the service conditions indicated in the Design Criteria section. The TYCO Style 60 Two-Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 GPM/psi112 (161,3 LPM/bar112) K = 14.0 GPM/psil/2 (201,6 LPM/bar'2) Temperature Ratings 135°F (57°C) to 286°F (141°C) Finish Sprinkler: Refer to Table A. Recessed or Flush Escutcheon: White Coated, Chrome Plated, and Brass-Plated Physical Characteristics Frame ....................Bronze Button ....................Bronze Sealing Assembly . . . Beryllium Nickel w/TEFLON Bulb.............Glass (3 mm dia.) Compression Screw .........Bronze Deflector ...................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria The TYCO Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Recessed Escutcheon is to be used for recessed installation, as applicable (Refer to Tables A, B, and C). UL and C-UL Listing Requirements The Series EC-11 and EC-14 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. The Series EC-11 and EC-14 Sprinklers are permitted to be used with unobstructed or non-combus- tible obstructed ceiling construction as defined and permitted by NFPA 13. For example: - Unobstructed, combustible or non-combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). - Obstructed, non-combustible, ceiling construction with a deflector location below struc- tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-11 and EC-14 Sprinklers, specifically tested and listed for non-combus- tible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under "Obstructions to Sprinkler Discharge Pattern Development". The minimum allowable spacing, to prevent cold soldering between Series EC-11 and EC-14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-11 and EC-14 Sprinklers are to be installed in accordance with all other require- ments of NFPA 13 for extended coverage upright and pendent sprin- klers, For example; obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to storage, etc. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees The Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers (TY5137. TY5237, TY6137 and TY6237) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: The stems of the concrete tee construction must spaced at less than 7.5 feet (2,3 m) on center but 2-7/8 DIA. - 1/2±1/8 (73,0 mm) 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER FITTING L. (3,2 mm) b!==--- MOUNTING SURFACE 721MOUNTING I PLATE CLOSURE 1-3/8' (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2-INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8 DIA. 5/8±1/4 (73,0 mm) - 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) (57,2 mm) ' FACE OF SPRINKLER 7.) 1/8" FITTING (3,2mm) - // t ..., // RL - MOUNTING / f \ MOUNTING SURFACE / \ PLATE CLOSURE 1-3/8" (34,9 mm): 7/8" (22,2 mm) FIGURE 3 SERIES EC-1 I AND EC- 14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4-INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FACE OF SPRINKLER FITTING: 3/8" (9,5 mm) ABOVE TO 1/8" (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4" (6,4 mm) ABOVE TO 1/2" (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT 2-7/8" DIA. - (73.0 mm) 2-1/4" DIA. (57,2 mm) H FH INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE - ON REDUCING SPRINKLER FITTING MOUNTING SURFACE (3,2 mm) CLOSURE 2-5/16" (58,7 mm) 3/4" NPT MOUNTING 1-13/16" (46,0 mm) PLATE FIGURE 4 SERIES EC- il AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 3/4-INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP22O Page 5 of 8 more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length exceeds 32 feet (9,8 m), non- combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Extended Coverage Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occu- pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to-ceiling distance. These criteria may differ from UL and/ or NFPA criteria; therefore, the designer must review and become familiar with Factory Mutual requirements before proceeding with design. TFP22O Page 6 of 8 Installation The TYCO Series EC-11 and EC-14 Sprinklers must be installed in accor- dance with the following instructions: NOTICE Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A 3/4 inch NPT sprinkler joint should be obtained with a minimum-to-maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mounting surface. Pendent sprin- klers must be installed in the pendent position, and upright sprinklers must be installed in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other escutcheon, as applicable) over the sprinkler pipe threads and with pipe Care and Maintenance The TYCO Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with the following instructions: NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Modified sprinklers must be replaced. Also sprinklers must be replaced that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like; are leaking or exhibiting visible signs of corrosion; were exposed to corrosive products of combustion but have not operated, if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush; or FITTING SIDE' TOWARDS SPRINKLER FITTING \ WRENCH :;'~! ( RECESS ENDA') FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - I 400 WRENCH HEX FIGURE 6 W- TYPE 22 RECESSED SPRINKLER WRENCH thread sealant applied to the pipe • have a cracked Bulb or have lost threads, hand tighten the sprinkler into liquid from the Bulb. Refer to the the sprinkler fitting. Installation section in this data sheet. Step 3. Wrench tighten upright or pendent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. When installing the pendent sprinkler with Style 30, 40, or 60 Escutcheon, wrench tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. The wrench recess of the applicable sprin- kler wrench (Ref. Figure 5 and 6) is to be applied to the sprinkler wrench flats (Ref. Figure 1). Frequent visual inspections are recom- mended to he initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it. may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (for example, NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP22O Page 7 of 8 Description Area Light Hazard 0.10 GPM/ft2 Group I Ordinary Hazard 0.15 GPM/ft2 Group II Ordinary Hazard 0.20 GPM/ft2 GPM PSI GPM PSI GPM PSI 14x14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 TY5137 (K=11.2) Upright 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14x14 - - 30 7.2 39 12.1 1Y5237 16 x 16 30 7.2 39 12.1 51 20.7 (K=11.2) Pendent 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14x14 N/A N/A - - - - TY6137 16x16 N/A 39 7.8 51 13.3 (K=14.0) Upright 18x18 N/A N/A 49 12.3 65 21.6 20x20 N/A N/A 60 18.4 80 32.7 14x14 - - - - - - TY6237 16x16 37 7.0 39 7.8 51 13.3 (K=14.0) Pendent 18x18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 itt. = 0.3048 m 1tt.2 =0.093 m2 1 psi = 0.06895 bar 1 GPM/ft2 = 40.74 mm/mm 1 GPM = 3.785 LPM TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-li AND EC-14 SPRINKLERS TFP22O Page 8 of 8 P/N 51 - XXX- X- XXX Sprinkler 1 Finish 1 Temperature Rating 1 Natural Brass 135 135°F (57°C) 4 White Polyester 155 155°F (68°C) 7 Lead Coated 175 175°F (79°C) 9 Chrome-Plated 200 200°F (93°C) 286 286°F (141°C) TABLE PART NUMBERS FOR SERIES EC- 11 AND EC-14 SPRINKLERS SIN 893 11.2K Pendent TY5237 894 11.21K Upright TY5137 895 14.0K Pendent TY6237 896 14.01K Upright TY6137 Limited Warranty Products manufactured by Tyco Fire Protection Products (TFPP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFPP. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFPP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFPP to be defective shall be either repaired or replaced, at TFPP's sole option. TFPP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFPP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFPP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFPP was informed about the possi- bility of such damages, and in no event shall TFPP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a partic- ular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, description, and P/N. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections Specify (SIN), (K-Factor), (temperature rating), (Pendent or Upright) Extended Coverage Sprinkler with (finish), P/N. Refer to Table E Recessed Escutcheon, Two-Piece Specify Style (30 or 40) Two-Piece Recessed Escutcheon with (material or finish), P/N. Refer to Technical Data Sheet TFP770. Flush Escutcheon, Two-Piece Specify Style 60 Two-Piece Flush Escutcheon with (finish), P/N (specify). Refer to Technical Data Sheet TFP778. Sprinkler Wrenches Specify W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Specify W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001. Copyright © 2007, 2012 Tyco Fire Protection Products. All rights reserved. two TEFLON is trademark of The DuPont Corporation. AS12-vool( tqcc lProducts /Fire & Building Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-B - 2.8, 5.6, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the 'INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail: to operate in a fire situation or cause it to operate prematurely. cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII5I - Upright 2.8K, 1/2"NPT 1Y1251 - Pendent 2.8K, 1/2"NPT TY3151 - Upright 5.6K, 1/2"NPT 1Y3251 - Pendent 5.6K, 1/2"NPT 1Y4151 - Upright 8.0K, 3/4"NPT TY4251 - Pendent 8.0K, 3/4'NPT TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.0K, 1/2"NPT Page 1 of 8 DECEMBER, 2007 TFPI5I Page 2 of 8 TFPI5I ESCUTCHEON 7/16' (11,1 mm) PLATE SEATING 1/2' ** NOMINAL SSU' SURFACE MAKE-IN DEFLECTOR NPT 5 2-1/4" (57,2 mm) (55,6m /16 WRENCH 3 2-3/16 6 (39,7 mm) FLATS _ 2 1-9 55p* 7 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3-Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 PLATE SEATING 1/2" ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR 6* (11,11 mm) 1 2-3/16" (55,6 mm) 7/16" NOMINAL MAKE-IN 11 2-3/16" WRENC (55,6 mm) (38,1 mm) FLATS SSP DEFLECTOR* H 2-7/8" (73,0 mm) DIA. 1/2" NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY3 151) AND PENDENT (TV3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" 6mm) (57,2 mm) 1- (39, 1/2" ** NPT TFPI5I Page 3 of 8 ESCUTCHEON 1/2' (12,7 mm) STYLE 40 PLATE SEATING ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR 1/2" * 2-5/16" (12,7 mm) NOMINAL (39,7 mm) HI 1-9/16 (58,7 mm) MAKE-IN 2-1 WRENC (57,2 mm) 3 FLATS SSP DEFLECTOR* 2-7/8 (73,0 mm) DIA. 3/4 NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TV-B UPRIGHT (TV4151) AND PENDENT (TV4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 7/16" (11,1 mm) NOMINAL SSU* MAKE-IN DEFLECTOR * 6 2-3/16 5 4 WRENCH 2 - - - _55,6m FLATS 3 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Page 4 of 8 TFPI5I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER LEAD COATED I WAX COATED I WAX OVER LEAD COATED 2.8 1/2" NPT PENDENT (TY1251) and UPRIGHT (TY115I) 135°F/57°C Orange 1,2,3 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286F/141°C Blue 360F/182C Mauve 1,2 5.6 1/2" NPT PENDENT (TY3251) and UPRIGHT (TY3151) 135°F/57°C Orange 12,3,45,6,7 1,2,3,5 1,2,3,5 1,2,3,5 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286F/141C Blue 1**,2**, 3** 5** 1, 2**, 3** 5** 360F/182°C Mauve N/A RECESSED PENDENT (TY3251) Figure 4 135°F/57°C Orange 1,2,3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286F/141C Blue 1,2 8.0 NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135F/57°C Orange 1,2, 3,4,5,6,7 1,2,5 1,2,3,5 1,2,5 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286F/141C Blue 1**,2**, 3** 5** 1*,, 2'', 5** 360F/182C Mauve N/A RECESSED PENDENT (TY4251)* Figure 5 135F/57°C Orange 1,2,3,4,5 N/A 155F/68°C Red 175°F/79C Yellow 200F/93°C Green 286F/141C Blue 1,2 8.0 1/2" NPT PENDENT (TY4951) and UPRIGHT (TY4851) 135°F/57°C Orange 1,2,3,4, 5,6 N/A 155F/68°C Red 175°F/79C Yellow 200°F/93C Green 286°F/141°C Blue 360°F/182°C Mauve NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01 -E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150°F/66°C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A, LABORATORY LISTINGS AND APPROVALS 4— TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER BRASS PLATED I POLYESTER COATED COATED LEAD COATED 28 PENDENT (TY1251) 1/2' and 175 PSI (12,1 BAR) N/A NPT UPRIGHT (TYII5I) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 1/2" UPRIGHT (TY3151) OR NPT 175 PSI (12,1 BAR) RECESSED PENDENT (TY3251) (SEE NOTE 1) N/A 8.0 PENDENT (TY4251) 3/4" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 8.0 PENDENT (TY4951) 1/2" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barll2) K = 5.6 GPM/ps1112 (80,6 LPM/bar112) K = 8.0 GPM/p5i112 (115,2 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 0140 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Page 6 of 8 TFPI5I 2-7/8 DIA. p.' 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) - (15,9±6,4 mm) - 2-1/4" DIA. I 1/4(6,4 mm) SPRINKLER PLATE FACE OF 57,2 mm) MOUNTING //i;:- 1/8" FITTING - __ - (3,2 mm) MOUNTING / SURFACE/ SERIES 1-1/4(31,8mm) CLOSURE TYB 3/4(19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER I PLATE FITTING 1/8" _ ______ _____ 3,2 mm) / MOUNTING SURFACE/ CLOSURE SERIES 1-5/16" (33,3 mm) TYB 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360°F/182°C temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the TFPI5I Page 7 of 8 sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TY-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire orinadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in ac- cordance with local requirements and/or national codes. Page 8 of 8 TFPI5I P/N 57-XXX-X-XXX MODEL/SIN - 530 2.8K UPRIGHT (1/2"NPT) TY1151 531 2.8K PENDENT (1/2"NPT) TY1251 570 5.6K UPRIGHT (1/2"NPT) TY3151 571 1 5.6K PENDENT (1/2"NPT) TY3251 590 8.0K UPRIGHT (3/4"NPT) 1Y4151 591 8.OK PENDENT (3/4"NPT) TY4251 560 8.0K UPRIGHT (1/2"NPT) 1Y4851 561 8.OK PENDENT (1/2"NPT) 1Y4951 SPRINKLER TEMPERATUF RATING 135 135°F/57°C 155 155F/68C 175 1750F/79*C 200 200*F/93*C 286 286°F/141°C 360 360°F/182°C 286*F/141*C MAX. 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010) * 9 CHROME PLATED 7 LEAD COATED 6 WAX COATED 6 WAX OVER LEAD 286°F/141°C MAX. * Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TV-B PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects inmate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foreaoina warranty is made in lieu press or Impliea. inciuning warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table C). Recessed Escutcheon: Specify: Style (specify 10 or 40 ) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446