HomeMy WebLinkAbout2200 FARADAY AVE; ; FA080087; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA080087 Job Address: 2200 FARADAY AV Permit Type: FALARM Parcel No: 2121204100 Lot #: 0 Status: ISSUED Applied 12/24/2008 Approved: 12/24/2008 Reference No.: Issued: 12/24/2008 PC #: Inspector: Project Title: SIERRA WIRELESS FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: DL FARADAY L P C/O DRA ADVISORS LLC 220 E 42ND ST #27 NEW YORK NY Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 SIERRA WIRELESS 2200 FARADAY AVE CARLSBAD, CA 92008 Fire Alarm Submittal 12/16/08 Submitted By: MA _ 3830 Calle Fortunada San Diego, CA 92123 (858) 654-3200 Lic. # 707408 Contact: STACEY TESCIER SIERRA WIRELESS Fire Alarm Submittal Euuiprnent List EXISTING EQUIPMENT Description Model Manufacture Fire Alarm Panel 5700 Silent Knight Fire Alarm Annunciator 5860 Silent Knight Smoke Detector 5D505-APS Silent Knight Addressable Input Module SDSOO-AJIVI Silent Knight Manual Pull Station SDSOO-PS Silent Knight Horn/Strobe 15cd PII224MCW System Sensor Connection to existing Waterfiow Switches Connecetion to existing PIV'S & OS&Y Switches CSFM# 7170-0559:144 7170-0559:144 7272-0559:129 7300-0559:132 7150-0559:136 7135-1653:163 Wire I 8I2Cond. (Initiation) Wire 14I2Cond. (Indicating) NEW EQUIPMENT Description Model Manufacture Addressable Input Module SD500-AIM Silent Knight Addressable Relay Module SD5 00-ARM Silent Knight Connection to existing Duct Detectors Connecetion to existing FM200 AND INTERGEN PANELS Wire 18l2Cond. (Initiation) Wire 14/2Cond. (Indicating) CSFM# 7300-0559:132 7300-0559:132 lntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. lntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and mainLnance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 18004466444, or in Minnesota, call 763493-6435. Description 5700 perforns drift compensation and calibration cnecks on each of the sensors in tie system. The basic Intel!iKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial, arallel printer interface module (ioi tinting system reports), and 5496 it .elligent power module. 5700 also ft:tures a powerful built-in dual line fire communicator that allows for reportiii of all system activity to a remote monitoring location. Features Up to 50 tdJressable points Up to 12 zones and 125 output groups Uses stalard wire—no shielded or twisted r required Built-in dcital communicator. Centra t tion reporting by point or by zone Support,,. class B (Style 4) and Class A (Style r or 7) configuration for SLC DistribLnt intelligent power Drift con znsation 13 pre-n jrammed output cadences (incluc NlSI-3.41) and 4 progra 1; able outputs Notific.,-,, ., circuits configurable as 1 Class A ..:yIe Z) or 2 Class B (Style Y), or a . ry power for resettable, constant r door holder power Built-in - chronization for AMSECO, GenteA Fnraday, System Sensor® and \A uck® appliances Built-in r ,uiiciator with 80-character LCD dn / RS-485 bus provides communication to system accessories Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5A at 27.4 VDC Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC Programmable date setting for Daylight Saving Time Electrical Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power-limited Standby Current: 200 mA Alarm Current: 325 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet Larger capacity batteries can be housed in an RBB accessory cabinet. Mechanical Specifications Dimensions: 1275" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Model 5700 Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA13, NFPA15, NFPA16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559:144; MEA429-92-E Vol. XVI. DSILENT KNIGHT by Honeywell SLC Detectors SD505-APS Addressable photoelectric smoke detector. SD505-AIS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 1350F-150°F (0°C-37°C). SD505-6AB Six inch base for use with detector heads SD505-APS, SD505-AIS and SD505-AHS. SD505-4AB Four inch base for use with detector heads SD505-APS, SD505-AIS, and SD505-AHS. SD505-6SB Six-inch sounder base for use with existing sensor and base. Operates in single and multi-station modes and/or as a system sounder. Requires 2 additional wires for power. SD505-61 B Short circuit isolator base for SD505-AHS, SD505-APS, and SD505-AIS detectors. SD505-CRB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SD505-AD H Duct housing that detects smoke in HVAC ducts. SD 505-AD HR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and SD505-AIS sensors. Compatible with SD505-DTS remote test switch. SD500-PS/SD500-PSDA SD500-PS is a single action pull station and SD500-PSDA is a dual action pull station. SLC Modules Model SD500-AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarm status. SD500-MIM Mini dry contact Input module is a small version of the SD500-AIM. For use with pull stations and other normally open dry contact inputs. SDSOO-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SD500-SDM Two-wire detector Input module. Allows for the connection of conventional 2-wire detectors on the SLC loop. Requires two additional wires for power. SD500-LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500-LEDs can be used per system. S-BUS Accessories 5860!R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R Is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/I0 Module Features 40 LED outputs, 8 normally open dry contact inputs and one plezo output 5865-3 and 5865-4 im Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 58654 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"Wx10"Hx6"D (406 mm W x 254 mm H x 152 mm D) SD505-DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with 5D505-ADHR. 13 SILENT This document is not intended to be used for Installation purposes. We try to 1[NrTr' 1-iT keep our product information up-to-date and accurate. We cannot cover all 1 specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight MADE IN AMERICA FORM# 350392 Rev. D, 04/06 Copyright © 2006 Silent Knight 5860 Color 5680R: Red 5680: Gray Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Approvals NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. IX; FM Approved SI LENT KNIGHT by Hbney*efl 5860 Remote Annunciator Bring the power to control an lntelliKnight fire alarm control panel to every area within your facility. "- Now you can operate and program your lntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighters key Larger keypad buttons for system reset and silence Install up to eight 5860s per FACP Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1"W x 7.4" H x 1.5" 0 (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to §Q fee.t FromfACP SBUS Up to Eight 58608 Per System Compatible lntelliknight FAcP Compatibility lntelliKnight 5820XL FACP lntelliKnight 5808 FACP lntelliKnight 5700 FACP Ordering Information 5680R Remote Annunciator Four line LCD annunciator with 20 characters per line. Red. 5680 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring For surface mounting. 5860TG Gray Trim Ring For surface mounting. D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369-4927. Phone: (800) 328-0103, Fax: (763)493-6475. MADE IN AMERICA FORM# 350224 Rev C, 05/06 Copyright © 2006 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LTSTING SERVICE USTING No. 7170-0559:144 Page 1 of I CATEGORY: Control Unit (High-Rise) USTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models *IFP 50 and *5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: RATING: INSTALLATION: IFP-50, 5700 7628 5860/5860R/RA-1 000 5897 5496 5824 5865-3/5965-4 5880 5883 SD500-LIM SD505-61 B RA-1 00 3158 5220 120 VAC Primary, 24 VDC Secondary Control Units EOL Resistor Annunciator Power Supply *Notification Power Expander Serial/Parallel Interface LED Annunciator LED 10 Module Relay Interface Board Line Isolation Module Isolation Base Remote Annunciator Reverse Polarity Module Direct Connect Module In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE- 360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912- 1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911- 1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details.- These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition.This control unit meets the requirements of UL-864, 8th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or p recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division SD500-AIM & SD-500-MIM Addressable Input Modules InteIIiKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or 'n Minnesota, call 763-493-6435. Description Up to 2500 ft wiring distance from either input module to contact b The SD500 AIM and SD500-MIM are I addressable input modules for use with Use up to 14 gauge wire the Intelliknight fire alarm control UL listed panels (FACPs). The SD500-AIM addressable input module mounts to a Electrical Specifications 4"-square box The SD500-MIM mini Standby Current 0.55 mA r2 input module fits inside a single gang Alarm Current: 23 mA max for one -'---------------- box. Both input modules are designed device; 46 mA max for two devices; SD500-AIM to be used with pull stations, water flow 0.55 mA for each additional device switches, and other applications requiring dry contact alarm initiation Line Resistance: 500 max devices. Mechanical Specifications These modules are supervised, single SD500-AIM Physical Description input contact monitors. Using an EOL Dimensions: resistor, they monitor for alarm contact 4.9 W x 4.9" H x 1" ID closures and for open circuit wiring (12.4W x 12.4 H x 2.5 D cm) SD500-MIM fault conditions. If a fault occurs in the Weight: 3.6 oz (120.1 g) wiring, the module alerts the FACP. Color: Ivory cover plate Each addressable input module is Approvals programmed with a unique signal line SD500-MIM Physical Description NFPA 71 & NFPA 72 circuit (SLC) loop address. Dimensions: UL 864 1.5' W x 2.5 H x 0.7 D CSFM 7300-0559:132 Features (3.8 W x 6.4 H x 1.8 D cm) MEA429-92-E Vol. IX Single contact monitor Weight: 1.6 oz (45.4 g) FM Approved for use with the 5820XL Support for Class A (Style 6 & Style Environmental 7) or Class B (Style 4) wiring Operating Temperature: Attractive ivory cover plate with the 32°F - 120°F (0°C - 49°C) SD500-AIM Small and lightweight size allows for flexible mounting options with the Humidity: 100/ °'°' non-condensing ° 0 SD500-MIM SILENT DIP switch programmable for fast KNIGHT 130 installation by Honeywell SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatibility Ordering Information IntelliKnight 5820 FACP SD500-AIM Input Module IntelliKnight 5808 FACP Addressable input module with ivory IntelliKnight 5700 FACP cover plate. SD500-MIM Mini Input Module Addressable mini Input module. SILENT This document is not intended to be used for Installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Al specifications are FORM# 350231 Rev.c, 05/06 subject to change without notice. For more information, contact Silent Knight byHoneywéll. 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2006 Silent Knight Phone: (800) 328-0103, Fax: (763)493-6475. Model SD500-ARM Addressable Relay Module Place relay applications anywhere on the lntelliKnight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps © 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model 0500ARM features Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A @ 30 VDC or.6A@ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Two sets of Form C contacts. Contacts are rated at 2A © 30 VDC or.6A@ 120 VAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible through cover plate. UL listed, complies with NFPA 72. CSFM approved MEAApproved, 429-92-E, Vol. 9 FM approved Oil F- V/I j Model SD500-ARM Specificaftons Contact Rating: Form C 2A @30 VDC .6A©I2OVAC Standby Current: .55 mA Alarm Current: .55 mA SILENT ]KNIGHT Ambient 32°F to 120°F Temperature (0°C to 49°C) Mounting 4-square electrical box Model SD5004ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW CAUTION REMOVE POWER PRIOR TO SERVICING ,SThENT1 : / 4 4-7/8" 1" Model SD500-ARM Addressable Way Module Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 553694927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350218, Rev. 11/01 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright 0 2001 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ____ OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:132 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD500-FRCM, SD500-FRCM-4 Monitor Modules and Model 8D505-ARM Relay Module. Models SD500-ARM, SD500-AIM, SD500-MIM Addressable Input Modules Models SD500-FRCM and SD500-FRCM-4 monitor modules provide inputs for a control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models SD505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC SD505-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0410:145 *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division - ___ .Telephone Number: FILE coi'' toe - eS . 1j-DSOo7 FIRE ALARM RECORD OF COMPLETION FORM DatS,/i./'3 Customer#,j Job#t '/1 C) 7 Primary System#. Secondary Sys'em#: N= Customer Name: Is / liZ 4 Address (City/State/Zip): 0 O ,t 4 'S1, 74c /~ b Representative of Protected Property (Name/Phor /. I Authority.Having Jurisdiction: .4 .t Location of As-Built Drawings: 4 Location of Operation and Maintenance Manuals: .1104 Location of Inspection & Testing Reports: Location of Control PaneW115 Primary Telephone NumbeI7. 4 oj 9 i / Secondary Telephone Numbe/760) '2 /2 Does ADT have a contract for testing and inspection in accordance with NFPA standard(s)? 0 Ye)o If no, who?:/VD U, J. c Inspection Start Date: Inspection Frequency: 0 Annually 0 Semiannually Quarterly 0 Bimonthly J Monthly 0 Weekly System Software Operating system (executive) software revision level(s): Site-specific software revision date: Revision completed by: (Name) (Company) (Date) Type(s) of System or Service 72, Chapter 8— ADT Central Monitoring Center Means of transmitting signals from the premises to the central station: (Check all that apply) . 4—Digital Alarm Communicator 0 McCulloh 0 Multiplex 0 One-way Radio 0 Two-way Radio 0 Other: Means of transmission of alarms to the public fire service communications center: System locations: D NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8- Remote Station Telephone numbers of the organization receiving alarms:/P 0- ct 0 NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: 0 NFPA 72, Chapter 9 - Auxiliary Check type1of connection: 0 Local Energy 0 Shunt 0 Parallel Telephone Telephone numbers of the organization receiving alarm(e',T t,4' - /7 '' '-.t /- cP 0 cP 9' / c1 If alarms are retransmitted to a public fire service communications center or other, indicate name and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted:41/ '7'( Record of System Installation (Complete this section after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior p.5 stjtlg I operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by .f'c. on , includes the devices shown in sections 4 & 5, and has been in service since This system has been installed in accordance with the standards as shown below: 1NFPA 72, Chapters 069 c'Q (9i 6o 1411, (Circle all that apply) 1- 1tJ NFPA 70, National Electrical Code, Article 760 El—Manufacturer's Instructions 0 AHJ or OtherSouroe! r L7~ c L Date: Reprinted with permission from NFPA 7282002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection '11111111111 liii 1111111111 111111111111111111111111111111111111111111111111111111111 Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. 0 1 1 0 0 0 5 0 3 0 0 1 0 5 0 8 F5030-01 . AHJ (p.1 of 3) or- FIRE ALARM RECORD OF COMPLETION, continued 3. Record of System Operation ( Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached 4/L.) .J°C C.i7J,/i./ All operational features and functions of this system were tested by date And found to be operating properly in accordance with the requirements of: 40" NFPA 72, Chapters 6I(7(8( 9 >I{ (Circle all that apply) NFPA 70, National Electrical Code, Article 760 (r El Manufacturer's Instructions E] AHJ or Other Source: SignedT Date: 3JJQ Organization 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Tab e 6.6.1): Quantity Style Class ) 5. Alarm-Initiating Devices and Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity .L Style S'/ c! Class Manual Manual stations Non-coded Coded Transmitters Addressable Combination manual fire alarm and guard's tour coded stations Automatic Coverage: (Check all that apply) Li Complete 0 Partial 0 Selective Li Non-required - - Enter quantities and check if the devices are addressable. Smoke detectors lop/ Photo Li Addressable Duct detectors Ion Photo Li Addressable Heat detectors FT RR FT/RR RC 0 Addressable Sprinkler waterflow indicators: Non-coded Coded Transmitters 0 Addressable The alarm verification feature is fl Disabled 0 Enabled , changed from seconds to seconds. Other (list):(%) ,'/yT ' t& '' //=4? /2, 6. Supervisory Signal-Initiating bëvicesaiid Circuits - Guards Tour: 0 (a) Coded stations • 0 (b) Non-coded stations Li (c) Compulsory guard's tour system comprised of - transmitter stations and intermediate stations. Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. (Check if provided.) SDrinkler System: Li (a) Valve supervisory switches Li (b) Building temperature points 0 (c) Site water temperature points Li (d) Site water supply level points 0 Other supervisory function(s) (specify): Electric fire um: Li (e) Fire pump power Fire pump running Phase reversal Electric-driven fire DumD: Li (h) Selector in auto position' Li (i) Engine or control panel trouble Li (j) Fire pump running Electric-driven generator: (k) Selector in auto position (I) Control panel trouble (m) Transfer switches Li (n) Engine running Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the I 11111111111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 liii 11111 11111 11111 liii HI NFPA on the referenced subject, which is represented only by the standard in its entirety. 0 1 1 0 0 0 5 0 3 0 0 1 0 5 0 8 F5030-01 (p. 2 of 3) AHJ 009 FIRE ALARM' RECORD OF COMPLETION, continued 7. Annunciator(s) %ç Quantity: / Type: Location(s):_i 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice alarm/alarm channels:: Single: Multiple: Quantity of speakers: Quantity of speakers zones: Quantity of telephones or telephone jacks attached to the system: Types and quantities of notification appliances installed: Bells With Visible: (d) Chimes With Visible: Speakers With Visible: (e) Other: With Visible: Horns I With Visible: (f) Visible appliances without audible: 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: /2. 0 1,/' Current rating Over-current protection: Type: c, //Lm._, /'ci.. Current rating Location: Secondary (standby): Storage battery: )( I2__ Amp-hour rating: Calculated capacity to drive system, in hours: (24) 2 ' (60) Engine-driven generator dedicated to fire alarm system: Location of fuel storage: * Emergency system used as backup to primary power supply: Emergency system described in NFPA 70, Article 700 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): ,4,'2' h&'1.' System deviations from the referenced NFPA standard(s) are: N Customer Comments: Customer's Name: Customer's Signature: Print Name Date Installer's Print Name Date Upon completion of the system(s) satisfactory test(s) witnessed (if required by the Authority Having Jurisdiction): AHJ Representativ' fo AHJ Representative Signature: Print Name Date Title: Telephone : Number. Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced 11111011111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 liii liii subject, which is represented only by the standard in its entirety. 0 1 1 0 0 0 5 0 3 0 0 1 0 5 0 8 F5030-01 AHJ (p.3of3)