HomeMy WebLinkAbout5858 EDISON PL; ; FA150019; PermitFire Alarm Permit Permit No: FA150019 Job Address: 5858 EDISON PL Status: APPROVED Permit Type: FALARM Applied 3/26/2015 Parcel No: 2120923600 Approved: 3/30/2015 Lot #: 0 Reference No.: Issued: 3/30/2015 PC #: Inspector: Project Title: EDISON PLACE LLC ADDITIONS TO EXISTING FIRE ALARM SYSTEM: INSTALL NEW FIRE ALARM CONTROL PANEL INSTALL NEW FIRE ALARM KEYPAD ANNUNCIATOR AND MANUAL PULL STATION BY RECEPTION ENTRANCE INSTALL NEW SMIKE DETECTOR ABOVE FIRE ALARM CONTROL PANEL RELOCATE EXISTING HORN/STROBE BY RECEPTION INSTALL NEW SOLE PATH CELLULAR ALARM COMMUNICATOR SYSTEM TO BE MONITORED BY 24 HOURS U.L. APPROVED CENTRAL STATION Applicant: Owner: TYCO INTEGRATED SECURITY 5858 EDISON PLACE L L C 3830 CALLE FORTUNADA SAN DIEGO, CA 1301 LAS ALTURAS RD SANTA BARBARA CA 760458-0161 Fees ($) Add'I Fees ($) Total ($) Balance ($) 289 0 289 0 FA1 50019 HIGHLIGHTED SET UL Certificate of Compliance Cut Sheets and CSFM listings for: 5858 EDISON PLACE L.L.C. 5858 EDISON PLACE CARLSBAD, CA 92008 Integrated Secutity! 3870 Murphy Canyon Road, Suite 140 San Diego, CA 92123 (858) 633-9521 UL Applicant ID No: 100584-325 Service Center No 768 Expires: 31-MAR-2015 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company.Indfcated below Is included by Underwriters Laboratories Inc. (UL) In its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance With UL's requirements Is the:issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors.slgnais from the protected property unless the use of a UL listed or Classified Alarm Trarispprt Company is specified on the Certificate. Listed Service From: AURORA, Co AIaim Service Company: (360682-221) Serviie Cehter: (360682-221) TYCO INTEGRATED SECURITY Lt-C. TYCO INTEGRATED SECURITY LLC 14200 E EXPOSITION AVE 14200 E EXPOSITION AVE AURORA CO 80012-2540 AURORA CO 80012-2540 The Alarm Service Company Is Listed in the following Certificate Service. Categories: File - Vol No, CCN Listing Category . 13P34 -192 CPVX [Surglar Alarm Systems Central Station 8994 - 183 UUFX [Sighal and Fire Alarm Equipment and Servicesi (Protective Signaling Services) Central Station www.boschsecurity.com 0 IMSCH Invented for life Four initiating zones (expandable to eight); up to 20 two-wire smoke detectors per zone Programmable through keypads or remote programming software (RPS) through .a Conettix interface module Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A 1'JAC power supply Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module The FPD-7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD-7024 FACPs support four on-board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two-wire and four-wire detectors configurable as Class A, Style D or Class B, Style B loops. Each zone can support up to 20 two-wire detectors, or any number of four-wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the FPD-7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD-7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Notification Appliance Circuits (NACs) Two Class A, Style 7 or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for Wheelock, Gentex, or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light-emitting diodes (LEDs) and liquid-crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off-normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR-7033 LCD Keypads connected to the system. Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer * The system stores events in a 99-event history buffer. Notice Lij The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module. Central Station Reporting The FPD-7024 FACPs send reports to two telephone numbers (or, if a Conettix interface module is installed, IP addresses) to an appropriate Conettix receiver at the central station with full single, double, and backup reporting. The panel supports communication in BFSK, SIA, Contact ID, Modem lila2 and 4/2 or 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on-board zones and FPC-7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the detector sends a Clean Me signal on the two-wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The FPD-7024 enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Certifications and approvals Region Certification USA UL UOJZ: Control Units, System (ANSI/UL 864) - 4 FM FPD-7024 CSFM see our website .4 FCC ESVAL04B7024 -4 FDNY- 46173 CoA Installation/configuration1notes ( Compatible Products The following products are compatible (refer to the product datasheet for country-specific certifications/ approvals) with the FPD-7024 FACP: Category Product ID and Description - 4 Batteries and 0126 12 V, 7 Ah battery Power Supplies D1218 12 V, 18 Ah battery FPP-RNAC-8A-4C Remote NAC power supply Detectors j For two-wire detector compatibility, refer to FPD-7024 Smoke Detector Compatibility List Techno gram (P/N: F01U010790) Keypads and D7030X Eight-point LED annunciator (eight red) Annunciators D7030X-S2 Eight-point LED annunciator (two yellow, six red) D7030X-S8 Eight-point LED annunciator (eightyellow) D7032 Eight-point LED annunciator expander (eight red) FMR-7033 LCD fire system keypad FMR-7036 LCD annunciator Modules D1328 Smoke detector reversing relay module D184A Local energy kit D185 Reversing polarity module D275 EOL power supervision module FPC-7034 Four-point expander 07039 Multiplex expansion module Option Bus D7035 Octal relay module Devices - - 07035B Octal relay module in box DX401OV2 USB/serial interface module DX4020 Network interface module 8420 Ethernet communicator 8426 Ethernet communication module 8440 Conettix plug-in cellular 8441 Conettix plug-in cellular 8442 Conettix plug-in GPRS cellular B443 Conettix plug-in HSPA+ cellular 8450 Conettix plug-in communicator interface ITS-DX4020-G GPRS/GSM communicator NAC Devices I Refer to FPD-7024 Device Compatibility List Technogram(P/N:F01U010791) The following additional products are compatible with the FPD-7024 Addressable FACPs: Category i Product ID and Description Detector Heads 07050 Addressable Photoelectric Smoke Detector and Bases 1Head D7050TH Addressable Photoelectric Smoke and Heat Detector Head D7050-136 Detector Base Modules D7042 Multiplex eight-input remote module 3 I FPD-7024 Fire Alarm Control Panels 07042B Multiplex eight-input remote module in box D7044 Multiplex single-input module D7044M Mini multiplex single-input module D7048 Multiplex octal driver D7048B Multiplex octal driver in box D7052 Multiplex dual-input module D7053 Multiplex input-output module Pull Stations FMM-7045 Single-action manual station FMM-7045-D Double-action manual station FPD-7024 Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure 1 Lock set with two #1358 (D102) key's (P1 N: F01U083084) 1 Transformer (P/N: F01tJ033706) 6 2.21 kOend-of-line (EOL) resistors (P/N: F01U034504) 1 Hardware pack 1 Literature pack Notice For the FPD-7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. FPD'7024-LC Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Hardware pack 1 Literature pack FPD-7024-LT (Latin America only) Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure 1 Lock set with two #1358(0102) keys (PI N: F011J083084) 6 2.21 k0 end-of-line(EOL) resistors (P/N: f01U034504) 1 Hardware pack 1 Literature pack FPC-7024FK1 Quant. Component 1 FPD-7024 FACP 1 F220-136E 6-in. (15.24-cm) diameter, 4-wire base with EOL relay 1 F220-P photoelectric spot smoke detector 1 SS-P2R Two-wire Horn Strobe 1 FMM-100SATK manual station (red) 2 D162@24 2-ft (60.96-cm) dual modular phone cord 2 0166@24 RJ31X phone jack Technical rispecifications Electrical Ctirrëht (aIarm). 380 mA 1 ' Current (standby)° 200 mA Power (primary): 120 VAC, 1.2 A maximum, 60 Hz or 240 VAC, 0.75 A maximum, 50 Hz * For product-specific current values, see the product's Installation Instructions. Environmental Environment: Indoor, dry Relative Humidity: lip to 95%, non-condensing Temperature (operating): +32°F (0°C) to + 120°F (+49°C) Mechanical Properties Color: I Red Dimensions (HxWxD):1 20.8 in. x 1 in. x 4.3 in. (52.8 cm 38.1 cm x 10.9 cm) Material: Cold-rolled steel i Base: l8 gauge (1.2mm) I Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current: 44 mA maximum per loop Line resistance: 1500 Voltage: 24VDCnominal Outputs MAC: 24 VDC nominal, 4 A maximum On-board Relays: Three Form C contacts rated at 5 A. 28V0C - - Off-board Relays: i Up to two 07035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 07053 Multiplex Input-Output Modules are allowed per bus for a total of 40 4 I FPD-7024 Fire Alarm Control Panels Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. r.1vrIyrnt.IdI FPD-7024 FACP Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024 FPD-7024-LC FACP without Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024-LC FPD-7024-LT FACP without Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. Order number FPD-7024-LT Accessories FPC-7024-FK1 Basic Fire Panel Kit Four-zone FACP with one four-wire photoelectric smoke detector and base with EOL relay, one two-wire horn/strobe, one manual station, and two RJ31X phone jacks with dual modular phone cords. Order number FPC-7024-FK1 D102 Replacement Key Replacement key (#1358) for the D101 lock. Order number D102 Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: Chine: America Latina: Bosch Security Systems, Inc. Bosch Security Systems By. Robert Bosch (SEA) Pte Ltd. Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Penlnton Parkway P.O. Box 80002 Systems 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98 Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishon Street 21 North IBP . CEP 13060-900 Phone: 11800 289 OSBB Phone: .x 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil Fax: +1 585 223 9180 Fax: +3140 2577 330 Phone: 065 6571 2808 200335 China Phone: *55 09 2103 2860 secuxty.sales@us.hosch,com emea.secunitysystemsbosch.com Fax: +65 6571 2899 Phone OBO 2122181111 Fax: +55 192103 2862 www.boschsecurity.us www.honchsecurity.com apr.securitysyntemsbonch.com Fax: *86 2122182398 Iatam.boschsecorlty@bosch.com www.bxscl-secority.asia www.boschsecority.com.cn www.boschsecority.com © Bosch Security Systems 2014 I Data subject to change without notice 2692228235 1 en, V17, lB. Dec 2014 1.0 Overview 1.1 System Overview This guide applies to control panels I equipped with version V1.00 or later software. The FPD-7024 Fire Alarm Control Panel is a fully integrated hard-wire fire alarm system. It can support four input points (expandable to 255 using D7039 Multiplex Expansion Module and the FPC- 7034 Four-Point Expander) and 16 individual users (expandable to 100 with the D7039). The control panel has a built-in LCD keypad. Up to four additional keypads can be used to provide user interface with the system and programming access for the installer. The FPD-7024 also includes the following features: . Built-in dual-line communicator Menu driven keypad programming Freely programmable alphanumeric/alphabetical display 99 event history buffer 16 user codes UL Listed, CS FM, MEA Approved When the D7039 Multiplex Expansion Module is installed, these additional features are available: 247 additional addressable input points (255 total points) 499 Non-volatile event history buffer 100 user codes Refer to Figure 1 for the location of the major items on the FPD-7024 Control Board. S Figure 1: FPD-7024 Control Board S 0000 qL~ ~C.o Dr'. - _ aPower •Troubie AIorrn •Slrenced r. • .Supervisory •Gnd Fit I 3 7 1. Telco Terminal Strip Relay Terminal Strip Smoke Power Terminal Strip Zone Input Terminal Strip Option Bus Terminal Strip FPC-7034 Point Expander Connector Pins - U Q w. 0. 4 Keypad D7039 MUX Expansion Module Connector Pins LCD Display 10 - NA Terminal Strip 11. Auxiliary Power Terminal Strip Bosch Security Systems, Inc. 1 1/09 1 F01U008458-02 7 Number of two-wire circuits Type of Circuit EOL Resistor - Supervisory Existing Required Existing for Alarm Maximum Short Circuit Existing Maximum Line Resistance Circuit Voltage Range Maximum Detectors per Point Total Detector Standby Existing Response Time* Dirty Detector Monitoring Four circuits, expandable to eight using an FPC-7034 Expander Class B, Style B and Class A, Style D as needed) 2.21 kO (P/N: 25899 or F01U034504), UL listed 8 to 20 mA 25 mA 45 mA 1500 20.4 to 28.2 VDC 20 detectors (two-wire) 3 mA maximum Either fast (500 ms) or programmable (from 1 to 89 seconds) Implements Bosch Security Systems, Inc. Chamber Check® and GE InterIogix, Inc. CleanMeTM protocol to monitor conventional loops for dirty detectors. 1.2 Components 1.2.1 On-board Conventional Points All on-board points and points implemented with the FPC-7034 work with two- or four-wire detectors. The system has an optional alarm verification feature. I Table 1: Two-Wire Circuits * Refer to Section 6.4 on page 81. All on-board points, and points activated with the FPC-7034 Four Point Expander, are continuously monitored for detectors signaling a dirty condition using the Bosch Security Systems, Inc. Chamber Check and GE Interlogix, Inc. CleanMe protocols. To prevent nuisance reports, a two-minute delay occurs before a dirty detector is annunciated. A six- minute delay occurs after the detector restores from the dirty condition before the control panel restores the condition. 1.2.2 Off-board Addressable Points (with D7039 Multiplex Expansion Module) The D7039 Multiplex Expansion Module adds: Two Class B, Style 4 or one Class A, Style 6 Signaling Line Circuits (SLCs) Each point is individually supervised for proper connection to the common bus (when over ten points are troubled, up to ten troubles are shown per bus and the balance of the troubles is indicated by a common bus failure message). Response time can be set to fast, or programmed from 1 to 89 seconds. Input points on the SLCs are implemented with a 07042 Eight Input Remote Module. 1.2.3 Enclosure Housing The standard enclosure is 18 ga., cold-rolled steel, and measures 20.75 in. x 15 in. x 4.25 in. (52.7 cm x 38.1 cm x 10.8 cm). A keyed lock is included, and the LEDs and LCD display are visible through the door. 1.2.4 Remote LCD Keypads Maximum number of keypads: Four FMR-7033 LCD Fire Keypads. Wiring Requirements: Refer to Section 2.2 Option Bus Wiring Requirements on page 19. 1.2.5 Remote LED Annunciators Maximum number of annunciators: Eight D7030 eight-zone LED Annunciators. Wiring Requirements: Refer to Section 2.2 Option Bus Wiring Requirements on page 19. 1.2.6 D7032 with the D7030X Use When a 07032 Eight-Zone LED Annunciator Expander is connected to the 07030X, eight additional LED zones appear. This allows the 07030X/07032 combination to show 16 LED zones. Up to eight 07030X/07032 combinations can be connected to the FPD-7024 Fire Alarm Control Panel. Refer to Table 2 on page 9 for zones shown by each 07030X/07032 combination. Each 07030X processes 16 zones of JV—JI information. If no 07032 is attached, only the lower eight zones are shown. The column labeled Shown on 07030X" In Table 2 on page 9 applies regardless if an attachment of a 07032 to any D7030X is made. Bosch Security Systems, Inc. 1 1/10 1 F01U008458-03 1.2.10 Backup Battery Calculation Use Table 4 to calculate the standby battery capacity required by NFPA when using the FPD-7024. Table 4: Standby Battery Capacity Calculations Device Quantity Standby Existing/Device Total Standby Alarm Existing/Devic e Total Alarm FPD-7024 Control panel FPC 7034 Four Point Expander 1 200 mA 200 mA 380 mA 380 mA 44 mA 156 mA 07035/13 Octal Relay' 8 Ma + 30 mA2 8 Ma + 30 mA2 D7048/13 Octal Driver Module 10 mA 10 mA FMR-7036 Annunciator Keypad 80 mA 100 mA D7030X Eight-Point LED Annunciator' 27 mA 132 mA 07030X-S2 Eight-Point LED Annunciator 35 mA 175 mA D7030X-S8 Eight-Point LED Annunciator 35 mA 175 mA D7032 Eight-Point LED Annunciator Expander 1 mA 90 mA FMR-7033 Keypad 1 80 mA 100 mA 07039 MUX Expansion Module - 150 mA 150 mA 07042/13 Addressable Eight Point Input 18 mA 18 mA 07050 MUX Photoelectric Smoke Detector 0.50 mA 0.56 mA D7050TH MUX Photoelectric Smoke Detector 0.50 mA 0.56 mA FMM-7045 Mux Pull Station 0.55 mA 0.55 mA D7044 Mux Single Input Fire 0.55 mA 0.55 mA D7044M Mux Mini Contact Module 0.55 mA - 0.55 mA 07052 Mux Dual Input Fire 0.55 mA 0.55 mA 07053 Mux I/O Module Fire 0.70 mA 0.70 mA Smoke Detectors Bells, Horns, and so on Other Sensors Other Grand Total Standby Existing Grand Total Alarm Existing 1The 24 VDC existing requirements for the 07030X, FMR-7033 and 07035 are shown at 75% of the 12 VDC level shown on the specification sheets for these models. The FPD-7024 regulates 24 VDC power from the battery to 12 VDC for these accessories. 2Add 30 mA for each relay activated Bosch Security Systems, Inc. 1 1/10 1 F01U008458-03 11 Specifications Table 32: Specifications. Temperature Storage and Operating Temperature: +32°F to +120°F (0°C to +49°C) Power Input Power: 220 V 50 Hz or 120 V, 60 Hz, 2.2 A Notification Appliance Circuit (NAC) Power: Each NAC has 24 VDC nominal, unfiltered power with up to 2.5 A capacity (but limited by overall 4.0 A capacity). Refer to FPD-7024 NAC Compatibility List (P/N: F01U010791) for compatible NAC devices. Auxiliary Power: 24 VDC nominal, unfiltered, 1.0 A Initiating Circuit (Smoke) Power: 24 VDC nominal, filtered, 1.0 A. Refer to FPD-7024 Fire Alarm Control Panels (P/N: F01U010790) for compatible smoke detection devices. Option Bus Power: 12 VDC nominal, 500 mA Optional Standby Batteries: Two 12 V (in series), 7 to 40 Ah Notification Appliance Two on-board notification circuits NAC 1 and NAC 2. These are 24 V outputs for Circuits (NACs) notification devices with up to 2.5 A capacity (but limited by overall 4.0 A capacity) on each circuit. Wire for standard Class B, Style Y or Class A, Style Z as needed. Configurable for patterns: steady, pulsing, California March, ANSI code 3, synchronized Wheelock, synchronized Gentex, and synchronized System Sensor. Relays Local Relays: The main control panel includes Three Form "C" relays. The relay contacts are rated at 5 A, 28 VDC. No over existing limiting is performed on the contacts of these relays. The default selection for the relays is to indicate general alarm and general system trouble and supervisory. By using point or zone mapping, they can be programmed to activate in a wide variety of conditions. When a local relay is programmed for trouble it is energized in the normal state. This causes the common and normally-open terminals to be shorted when not I in the trouble condition. D7035 Remote Relay Module: The D7035 is an octal relay module that provides eight Form C relay outputs. It connects to the FPD-7024 through the option bus. The outputs are fully programmable, exactly as the local relays are programmed. Each output operates independently of the other seven to provide complete flexibility. Communication with the D7035 is supervised. Contact Rating: 5 A @ 28 VDC Number of Modules: two units maximum Wiring Requirements: Refer to Section 2.2, Option Bus Wiring Requirements on page 19. 98 Bosch Security Systems, Inc. 1 1/10 1 F01U008458-03 U FPC07034 Four-Point Expander . £dds four Class B (Style B) or Class A (Style D) Initiating circuits to the FPD-7024 FACP For use with normally-open (NO) or normally-closed (NC) alarm contacts Compatible with two-wire or four-wire smoke detectors Up to 20 two-wire smoke detectors per circuit Easy installation due to plug-in design and screw terminal circuit connections No programming necessary The FPC-7034 Four-point Expander doubles the number of alarm initiating device circuits on the FPD-7024 Fire Alarm Control Panel (FACP). These circuits are identical to the circuits on the FACP. This plug-in module is automatically recognized by the control panels firmware when power is restored to the system. Certifications and Approvals Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615:227 I installation/Configuration Notes Compatible Products The following products are compatible with the FPC-7034 Four-point Expander: Category Product ID Product Description Control FPD-7024 Addressable or conventional FACP Panels Detectors Refer to FPD-7024 Smoke Detector Compatibility List Technogram (P/N: F01 U010790) for a list of smoke detectors compatible with the FPD-7024 FACP. Note When four-wire smoke detectors are used, power must be supplied to the detectors from either the control panel or an external power source. Mounting Considerations The FPC-7034 mounts on the FPD-7024 control board, just to the right of the keypad. Use the four nylon stand-offs supplied with the expander. Initiating Circuit Wiring Circuit connection for the expansion initiating circuits is identical to the on-board circuit configuration. Refer to the FPD-7024 Installation Guide (P/N: F01U008458) for wiring details. Install a supplied EOL resistor at the end of each wiring run. www.boschsecurity.com 2 1 FPC-7034 Four-Point Expander S iPartded - Quant. Component 1 Four-loop expander board 4 2.21 kO End-of-Line (EOL) Resistors (P/N: 25899) 4 Stand-offs (P/N: 265 10) 1 Literature pack * Technical Specifications - Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F to +122°F (0°C to +50°C) Mechanical Properties Dimensions 2.0 in. x 4.5 in. x 1.3 in. (5.1 cm 11.4 cm x3.3 cm) (HxWxD): Response Time: Choice of fast (500 ms) or programmable from 1 sec to 89 sec Power Requirements per initiating circuit: Alarm Current (short circuit): 40 mA maximum Alarm Current (threshold): >25 mA Detector Standby Current (total): 3 mA maximum Loop Supervision Current: 8.0 mA to 15.0 mA Trouble Current Threshold: <7 mA Voltage (supply): - 18.0 VDC to 25.5 VDC per FPC-7034 module: Current (standby): _60mAmaximum Current (alarm): 160 mA maximum - Ordering Information - - - FPC-7034 Four-Point Expander FPC-7034 Doubles the number of alarm initiating device -. circuits on the FPD-7024 FACP Americas, Europe, Middle East, Africa, A*iwPoclfic, Represented by Bosch Security Systems, Inc. Busch Security Systems B.V. Busch Security Systems Pte Ltd 130 Perinton Parkway P.O. Bun 80002 38C Jalan Pemimpin Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 577180 Phone: +1800 289 0096 Phone: 03140 2577 284 Phone: *65 6319 3450 Fax: +1585 223 9180 Fan: +31402577 330 Fax: +85 8319 3499 security.sales@us.bosch.com emeu.securitysystemsbosch.com upr.securitysystems@bosch.com www.boschsecurity.us www.buschsecurity.com wwnn.buschsecurity,curn C Bosch Security Systems Inc. 2008 I Data subject to change without notice T2792759179 I Cur: en-US, V2, 8 Dec 2008 S FMR-7036 Fire Annunciator Keypad Compatible with FPD-7024 Fire Alarm Control Panel Two-line, 16-character LCD display On-board LEDs indicate Silenced, Trouble, Alarm, and Supervisory Silence and Reset buttons Built-in keyswitch Attractive, low-profile enclosure UL Listed The FMR-7036 is a four-wire LCD annunciator keypad used with the FPD-7024 Fire Alarm Control Panel (FACP) to establish the location of a fire alarm. The two-line, 16-character display is capable of showing all messages normally displayed on the control panel. All alarm and status messages are included. Four on-board LEDs provide easy reading of the annunciators status from a distance. There are Silence and Reset buttons for controlling annunciator and control panel operation. A built-in keyswitch offers extra security by locking the annunciator to prevent unwanted sounder silencing or control panel resetting. [Certifications and Approvals - - Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615:227 [1tnTho 1 Compatible Products Category - Product ID Product Description Control Panels 'FPD-7024 Four-zone FACP, Mounting The FMR-7036 can be surface mounted on a standard three-gang box, or with the mounting backplate provided. Wiring Guidelines For the FPD-7024 FACP, the maximum allowed DC current draw from the option bus is 500 mA for keypads. The maximum length of wire (all branches added together) that can be connected to the option bus terminals is 4000 ft (1220 m). The maximum length between any one device and the control panel terminals depends on the current draw on the branch that the device is on. The current draw on a particular branch can be found by adding together the individual current draws of each device connected to the branch. Note Refer to the FPD-7024 Installation Guide (P/N: F01U008458) for complete wire length calculations. www.boschsecurity.com L2 I FMR-7036 Fire Annunciator Keypad Number of Keypads Up to four keypads can be used per system. Up to three keypads can be used on any single 1000 ft (305 m) run of 18 AWG (1.2 mm) wire. Parts Included Quant. Component 1 LCD annunciator keypad 1 Literature pack Technical Specifications Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F to 120°F (0°C to +49°C) Mechanical Properties Base Dimensions (HxW): 4.6 in. x 8.2 in. (11.7 cm 20.8 cm) Cover Dimensions (HxW): 4.3 in. x 8.1 in. (10.9 cm 20.6 cm) Power Requirements ,Current (Alarm): 100 mA' Current (Standby) • 80 mA nominal' -- Voltage (Operating): 12 VDC nominal Ordering Information FMR-7036 Fire Annunciator Keypad FMR-7036 Four-wire LCD annunciator keypad used with the FPD-7024 Fire Alarm Control Panel to establish the location of a fire alarm Accessories KEY-ANN Replacement Key KEY-ANN This is a spare or replacement key for the D7036 lock. Americas, Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: *18002890096 Fax: +1 585 223 9180 secunty.sales@us.bosch.com www.boschsecunity.us Europe, Middle East, Africa, Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: * 31402577 284 Fax: +3140 2577 330 emea.secaritysystems@bosch.com www.boschsecurity.com Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemlnnpin Singapore 577180 Phone: *65 63193450 Fax- +65 6319 3499 apr.securitysystems@bosch.com www.bqschsecurity.cam Represented by © Bosch Sonority Systems Inc. 2008 I Data subject to change without notice T2782761483 I Cur: en-US, V2, 8 Dec 2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. -. 7165-1615:0227 Page 1 of I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: 'BOSCH SECURITY SYSTEMSI30 Perinton Parkwy, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033,FMR-7036; Keypad 07035, D703513; Expanded Relay Module D185; Reverse Polarity Module D7039; MUX Expander D7042, D7042B, 07044, D7044M, D7052, D7053; Mulitplez Expander Module 07048, D704813; Octal Driver Module *B440 B441; Cellular Modules *13450; Interface Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 04-22-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PA RSEGIA N, Program Coordinator Fire Engineering Division NP SERIES - NPI8-12 'Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation. Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the 'ecombinationof gasses with inthe cell, the battery is almost naintenance free. rminàls Bolt fastened terminal E 4-12 • 02 1 .472 12.00 .453 11.50 1H .433 11.00 .:U T0 Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications Nominal Capacity (Ah) NPI8-12 20hrto 175vpc300C 17.2' lOhrto 1.75vpc20°C 16 51hrto 1 70vpc20°C 14.5 lhrto 1 60vpc20°C 10.3 Voltage 12 S. Energy Density MiL'2Or) 94 SpecificE 2ohr 38 Int. Resistance (h Oms) 11 MaxirnumdrLthIiulY 112 Short Circujt(c U rn/t(A) 500 Dimensions (mm) Length 180 Width 76 Height overaJl - 167 Weight (Kg) 6.2 Terminal E Layout 2 Terminal Torque Nm - o u t/ 2 e I' I Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge - 15°C to 50°C Discharge — 20°C to 60°C Storage - 20°C to 50°C (fully charged battery) FLOAT CHARGE CHARACTERISTICS 0.25CA- 2.275VP0 CONSTANT VOLTAGE CHARGING /5) ('.CA) M ATaO'C(68F) 4 cRAGIsGTlu(HouRS) TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS. DISCHARGE CURRENT 0.1 IC Arr. (F.V I.?VCELL CHARGING CURRENT 0.09C Ao' CHARGING VOLUME: '2S% OF DISCHARGED CAPACITY AH%I AMBIENT TEMPERATURE: 20C110 25C 4°F TO 77F) 42 - 100% 60% 50%OCPTI 000 000 000ISCO1 GE NUMBER OF CYCLES Distributed by SELF DISCHARGE CHARACTERISTICS 114)100 0 9 12 65 16 STORAGE TP.IC {MONThS) ,~REM F NP SERIES — NPI8-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME HA C-g. • sny COog. 0.2 I50 -17 I L Thsi 110,6.10 ______________ 0.3 125 IS I 0.15 00, Chargo C4-1 :. ii .IIL I1II1Pi!!! ii Pull I1lIIIII — slim 10011101 uiiiii•iiiii M60UTES HOURS FLOAT SERVICE LIFE NP RANGE (AH%) 1ES1INGCONVITNS FLOO71NO VOLIACEI 2.270V70 0.) 1,EWTTIECOAII.051Z26C l0SVTO lOT) LIFE T r Yuasa Battery Inc. Laureldale, PA 19605 2901 Montrose Ave fj www.yuasabatteries.com LI U Registered number 1548820 ' UASA Cat. No.1 rw7-12 January 08 I - TELULAR-." Meets UL 864 requirements for sole or Connects to your central station's PSIN dual path communications technology or IP receivers Supports virtually all alarm formats for • Increases your RMR while saving your universal panel compatibility customers money The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems i The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system, replacing all of the landlines your customers currently dedicate to their master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. Furthermore, each month they will pay you instead of the local telephone company for the communications path. For each landline they replace with a TG-7FS, their monthly communications bill decreases while your RMR increases. I Your customer currently has installed... You can replace it with... Customer Your RMR FIRST PATH SECOND PATH FIRST PATH SECOND PATH SAVES* INCREASES* rTTIIhT: rTTIti,i: TG-7FS Not Necessary liii (II. (5 min Supervision) Cellular rIyllhT:(Daily Supervision) TG-7FS Not _ (5 min Supervision) Necessary r1TIIimi: Other (5 TG-7FS min Supervision) Not Necessary Savings based on the estimated monthly cost of a business line compared to the estimated customer charge for monthly cellular monitoring. y being able to signal failures to the central station within five minutes of an outage, the TG-7FS cn be installed as the sole path for commercial fire installations. When installed with multiple cmmunications technologies, such as DACT, it is acceptable to supervise the cellular communication Oath just once daily. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode. UL Listings Commercial Fire Listings 864 - Control units and accessories for alarm systems Commerical Burglary Listings 365 - Police station connected burglar alarm units and systems 1610 - Central station burglar alarm units Residential Listings 985 - Household fire warning systems 1023 - Household burglar alarm systems Power Transmit power 1.0-2.0W (maximum allowable) Current consumption 60mA (stand-by) 250mA (transmission) Transformer supplied: 12VAC, 800mA UL listed plug-in Radio Transceiver Dual band cellular and PCS GSM 850MHz: Class 4 (2 watts) GSM 1900MHz: Class 1(1 watt) Antenna 9" dipole with 2dBi gain with 12 feet of cable and universal mounting bracket FCC part 15, 22, 24 & 68 compliant Telguard TG-7FS . Sole Path Cellular Alarm Communicator for Commercial Fire System Specifications Standard Features Full data reporting Automatic self-test (5 minute, daily, weekly or monthly) Power supply with battery harness Locking, red metal enclosure Two programmable supervisory trip outputs Alarm format support for S1A2, Contact ID, pulse (3xl, 42), modem lie, & 111a2, DMP Telephone line monitor built-in Physical Details 75"H x 11.5W x 3.5"D, Weight: 8 lbs. Operating environment: 0°C to +50°C; up to 95% humidity (non-condensing) Advanced Reliability Available relay output for tripping the alarm control panel when a trouble condition occurs Automatic Self-Tests with central station notification ensure the cellular system is operating 128 bit AES (Advanced Encryption Standard) alarm signals ensure authentication and security Accessories ACD-35/50/100 feet of low loss, high performance cable HGD-0 High gain, directional antenna LPD-0 Low profile, high gain antenna EXD-0 External, high gain antenna r A CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS TELGUARD COMMERCIAL FIRE Telguard Online Telcjuard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7 This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. Telguard Cellular Service Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Advanced Reliability Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. Automatic self-tests with central station notification ensure the cellular system is operating, Available relay output for tripping the alarm control panel when a trouble condition occurs. PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self-tests. Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7F5 is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7F5, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems For the most current product specifications and UL Listings visit www.Telguard.com. 4 AIR, CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS TELGUARD Power I Transmit power: 1.0W-2.0W (maximum allowable). ) al Power Consumption: A ,, P Cent,ai Stator, F,,e 60mA (Standby) 'I 25OmA (Transmission). Transformer: 12VAC, 800mA UL listed plug-in. Telguard technology allows full data reporting for unlimited Radio Transceiver point-to-point signal details and maximum transmitting power for superior in-building penetration. 3G cellular radio. GSM 850MHz: Class 4 (2 watts). GSM 1900MHz: Class 1(1 watt). UMTS WCDMA FDD 850/1900MHz. Antenna: 9" dipole with 2dBi gain, 12 ft of cable and universal mounting bracket. FCC part 15, 22, 24 and 68 compliant. Physical Details TG-7FS: 7.5" H x 11.5" W x 3.5" D. Shipping Weight: 8lbs. Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). Standard Features Full data reporting. Automatic self-test (60 mm. & daily). Power supply with battery harness. Locking, red metal enclosure. Two programmable supervisory trip outputs, Alarm format support for SlA2, Contact ID, pulse (3x1, 4x2), modem Ile, & lIla2, DMP. Telephone line monitor built-in, with Standard Line Security. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. ./".A ELECTRONIC SECURITY ASSOCIATION NFPN LISTED INTERNATIONAL Telguard, a Division of Telular Corporation • Cumberland Center IV. 3225 Cumberland Blvd • Suite 300 . Atlanta, GA 30339 • USA 800-229-2326, Option 5 . www.Telguard.com • Copyright ©2012 Telular Corporation • All Rights Reserved Telguard Model TG-7FS QUICK INSTALLATION GUIDE [SOLE PATH] Installation Summary There are seven steps in installing Telguard properly. IF YOU DO NOT PROCEED IN THE ORDER AND MANNER PRESCRIBED, YOU MAY NOT COMPLETE THE INSTALLATION IN THE TIME ALLOCATED. STEP 1: REGISTER FOR CELLULAR SERVICE Complete the Registration Form online at www.Telguard.com or fax the form to Telguard Customer Service prior to leaving for the job site. Telular requires this information to register and activate the unit. pu Ir\ -I2 L.L I ac000aa.O Z5 20 8 -sg. - LEDs 2-6 LED It .;--- At --u - DIlU 3 — — E 0, 0.131111 At - oaii In acQ. CL 000U DODD • DODD q 0 CD ZI Z2 22I HO_. :o Thc?u TO TO-iFS LED I LED? LED LED LED LED 1102 LED I I0 I • DOUQQQa DI a C, C DU 8. Hsi a STEP 2: LOCATE UNIT AND MEASURE SIGNAL STRENGTH (RSSI) First, you will be confirming that Telguard has adequate cellular signal strength. Press the LED/RSSI Mode Toggle button one time, LEDs will now indicate signal strength. Minimum recommended is 3 (3 on solid) with a multiple towers in range (LED I on solid). Press the LED/RSSI Mode Toggle button a second time to exit RSSl mode. STEP 3: CONFIGURE PANEL ALARMS FOR SOLE PATH CONNECTION Fire panels are typically provided with two Telco connections. Because the TG-7FS provides a single connection, the panel must be set up accordingly. The firs method of installation is to configure the panel to disable the Telco connection. If this is not an option due to panel limitations, it is possible to splice both TIP and RING connections from the panel into the single jack of the Telguard. The TG-7FS is capable of providing dial tone to both Telco connections. STEP 4: PROGRAM, ACTIVATE & TRANSMIT PANEL ALARMS OVER THE CELLULAR RADIO NETWORK Program the TG-7FS for Sole Path communication. You may do this by setting Memory Location 831 to a value of 3, using a butt-set. (See programming guide on reverse). LED 3 will be off when idle if successful. Next, connect the alarm panel's digital dialer output to Telguard and verify that alarm signals can be reliably sent through Telguard over cellular to the central station digital receiver. A minimum of two alarm signals must be transmitted. (NOTE: THE FIRST ALARM WILL ACTIVATE THE UNIT AT THE TELULAR COMMUNICATION CENTER, IT WILL NOT GO TO THE CENTRAL STATION, ALL SIGNALS AFTER THE FIRST ARE SENT TO THE CENTRAL STATION) STEP 5: CONNECT SUPERVISORY TRIP OUTPUTS Next, you will wire Telguard's supervisory trip outputs to the alarm panel and then test. STEP 6: CONNECT TRIP INPUT (OPTIONAL) Optionally, you can wire the external relay input to the trip input lead and ground, and test. STEP 7: COMPLETE THE INSTALLATION Your last step will be to attach earth ground, and permanently mount the unit. The LED/RSSI mode will reset to normal after 10 minutes. Setup & Programming the Operating Parameters in the Telguard TG-7FS When the Telguard is received from the factory and is powered up for the first time, it is immediately ready for activation, provided the default settings are what you want (note: registration form must be sent to Telular). The STC LED # 2 will flash to indicate any failure conditions. The Mode LED # 3 will be on and the SIC I and STC 2 relays will be tripped. If changes are required to the default settings, the Telguard can be programmed using a line-mans butt-set connected to T & R Test Points or a POTS phone connected to the panel RJ-45 jack (black connector where the alarm panel is normally connected). TO PROGRAM THE Tel-guard TG-7FS Put the line-mans butt-set in talk mode or pick up the POTS phone. Dial "#', you will hear 2 beeps. Press #, * this will put the Telguard into a Master Access programming mode, 2 beeps. Enter changes required. The syntax for programming a specific memory location is as follows: MEMORY LOCATION (3-digits), will respond with 2 beeps, then VALUE, will respond with 2 beeps. Then press * you will hear 2 beeps then hang up. This saves the change and exits the programming mode. Mem Loc. Field Default Value Setting 831 = Telco Primary/Cellular Backup Mode of operation 1 2 = cellular Primary/Telco Backup 3 = cell Only 01 = 4x2 pulse, 40pps 2300 hz 02 = 4x2 pulse, 20pps 2300 hz 03 = 4x2 pulse, lopps 1400 hz 04 = 3x1 pulse, 40pps, 2300 hz 833 cic Reporting Format 09 05 = 3x1 pulse, 20pps, 2300 hz 06 = 3x1 pulse, lopps, 1400 hz 07 = Radionics lie or 111a2 08 = Contact ID 09 = Auto Format Detect 11 = S1A2 (300 Baud) 12 = DMP Enter the SUM TOTAL of the events that you wish to trip the SIC relay by srci Trip Output 04 ADDING the corresponding values: 850 Reporting (LFC only) 00 = Not Used 04 = LFC 32 = DTF Normally Open 01 =AC Failure 08 = NSC 63 = ALL 02 = Low Battery 16 = RFC Enter the SUM TOTAL of the events that you wish to trip the SIC relay by STC2 Trip Output 59 ADDING the corresponding values: 851 Reporting (all except LFC) 00= Not Used 04= LFC 32=DTF Normally Closed 01 = AC Failure 08 NSC 63 = ALL 02 = Low Battery 16 = RFC 1=30 seconds 4=10 minutes 7=45 minutes 852 SIC Trip Delay for NSC 2 (60 sec) 2=60 seconds 5=20 minutes 8=60 minutes 3=3 minutes 6=30 minutes 9=24 hours 0 = terminate SIC history display mode 858 SIC History N/A I = start SIC history display mode 2 = clear SIC history 861 CFC Number of Events 0 (disabled) 0 = disabled 2 = 4 attempts I = 2 attempts 3 = 8 attempts 862 CFC Between Events 1(30 sec) 1 = 30 seconds 3 = 70 seconds 5 = 90 seconds 2 = 60 seconds 4 = 80 seconds 6 = 99 seconds 868 PPF Delay 0 (disabled) 0 = disabled, 1 = 10 seconds, 2=20 seconds, ... 15=150 seconds 872 AC Failure Delay 02 (2 hours) 0-24 hours 873 Trip Input Reporting 0 (no report) 0 = no report 1 = report trip 874 Trip Input Restoral Reporting 0 (no report) 0 = no report I = report restoral 875 Trip Input Swinger Function 0 (disabled) 0 = swinger function disabled I = swinger function enabled 899 Factory Default Unit NOTE: SPECIAL LED INDICATIONS DURING ACTIVATION If the Telguard fails to confirm activation it will be displayed on the LEDS: System Status LEDs Activation Indications LEDS 1-5 FLASHING FAILED ACTIVATION -SIGNAL TOO WEAK LED #1 & LED #4 FLASHING ACTIVATION ERROR - CALL TECH SUPPORT LED #1 ON ACTIVATION SUCCESSFUL LED #1 Off NOT ACTIVATED NEED TO CONNECT PANEL AND TRIP ZONE On either a FAILED ACTIVATION or ACTIVATION ERROR, the unit MUST BE RESET BY PRESSING THE RSSI BUTTON TWICE. The activation message MUST BE RESENT or the TELGUARD will not transmit signals through the cellular network. Repeat step 4 above. Appendix 4 - Detailed Specifications Dialer to Interface Electronics The patented integrated interface by Telular Corporation, allows digital dialers to dial into the cellular radio network. Line voltage: -30 Vdc into standard telephone device when on-hook. Dial tone: Precision 350 + 440Hz +1- 1%. 10 digits dial out capability. Mode: Loop start only. 25mA +1- 10% off-hook. Protected by U.S. Patents: 4,658,096; 4,775,997; 4,922,517; 4,737,975; 4,868,519; 5,134,644. Power Maximum AC current draw: 125mA (battery charged) 350mA (battery charging) Battery Supply: Maximum full charge DC voltage = 13.8V +1- 0.2V. Battery charging system: Constant current, Electronic short circuit protection Maximum charging current of 240mA Transformer Supplied: 12 VAC 10VA, UL, plug-in; acceptable transformers: GlobTek part number: WA1E800JOO-N-GTGTAB Tri-Mag part number: WTD-1208-C Digital Cellular Radio The Telguard TG-7 radio supports GSM/GPRS cellular protocol. It is equipped with an integrated radio transceiver conforming to all the requirements of the GSM Phase 2+ tests specified in GSM 51.10. The TG-7 transceiver is FCC compliant, meeting all of the requirements of Part 22, Part 24 and SAR testing. It is also compliant to the PTCRB NAPRD03 requirements. Frequency bands supported: GSM 850/900/1800/1900MHz, Antenna Port: TNC connector (female), 50-ohm Receiver Sensitivity: -107dBm Transmit Power: EGSM 850MHz: Class 4 (2 watts) GSM 1900MHz: Class 1 (1 watt) FCC ID: N7NWISM0228 Supplied Antenna: Dipole Physical Size: 11.4" x 7.75" x 3.3" (TG7GA003 12.5" x 12.5" x4.25") Shipping weight: 51bs (TG7GA003 14 Ibs) Operating Environment: 0 C to +49 C; 0 - 95% humidity (non-condensing). Telco Interface Ringer equivalence: 0.3B REN 56042303 28 © 2011 Telular Corporation Basic Hardware: Model TG-7 Model TG-7 (p/n 1G760003) meets the requirements for Household Burglary, Household Fire, and Commercial p/n TG7G0003 Fire installations. It has a metal enclosure, key lock, and dipole antenna with 12 feet of antenna cable. TG-7 is UL Listed for the following: UL Household Burglary UL Household Fire UL Household Burg/Fire Combination UL Fire Remote Station Model TG-7FS The TG-7F (p/n TG7GFS03) is similar to the standard TG-7 but with a red metal enclosure instead of beige. TG-7F p/n TG7GFS03 has all of the listings of the standard TG-7, as well as: UL Commercial Fire Model TG-7A Model TG-7A (p/n TG7GA003) meets the requirements for Household Burglary, Household Fire, and Commercial p/n TG7GA003 Fire installations. In addition to all the UL listings of TG7GFS03, TG-7A model can be used in the following applications. UL Bank, Safe and Vault ACD-12 12 feet of antenna cable and mounting bracket ACD-35 35 feet of low loss higherformance antenna cable and mounting bracket ACD-50 50 feet of low loss high performance antenna cable and mounting bracket ACD-100 100 feet of low loss high performance antenna cable and mounting bracket HGD-0 High Gain Directional Antenna 56042303 29 © 2011 Telular Corporation Installation Addendum for TG4FS Units Being Installed as Sole Path Communicators Introduction The recently release 2010 edition of NFPA 72 now allows the TG-7FS to be utilized as the sole path for fire communications. This product is UL listed for this specific purpose and meets both the communications integrity and power requirements for UL864. By following Telular's installation guidelines, the installer can provide the best conditions for a stable, sole path connection. Ensuring a Highly Reliable Cellular Connection In order to ensure that the 141 cellular path to be used for System Status 2 D'J LEDs 3 t NMUST BE LIT signaling has the highest 4' 0 5)I reliability possible, it is PowerLEo necessary to confirm two additional conditions, TG-7FS beyond what is outlined in the TG-7 Installation Guide. Checking For Multiple Cell Towers The Telguard TG-7 series supports the detection of multiple cell towers, which provides an indication that cellular service will still be available, should the primary tower lose service for whatever reason. When the Telguard unit's LED display is put into RSSI mode (by pressing the display mode button), the top LED (LED 1) will be lit if the Telguard unit detects multiple active cell towers within range. Ensure Optimal Signal Strength Installation instructions for the Telguard TG-7 series indicate that a signal strength of -90dBm is sufficient. While this is suitable for "normal' use, i.e. daily, weekly or monthly supervision, an additional level of signal integrity will minimize the false alarms supervision failures caused by interference and atmospheric fading. Because of this, a signal strength. of -80dBm, as indicated by at least 3 illuminated LEDs (LEDs 3, 4 and 5), is the recommended minimum for units installed as sole path communicators. strength by installing an external antenna. Telular provides a variety of antenna options as accessories; consult your local distributor for more information. Configuring a Sole Path at the Panel Fire panels are typically provided with two telco connections, in order to provide multiple reporting paths. With the TG-7FS configured as a sole path communicator, one of these telco connections is no longer necessary for UL 864 compliance. However, the panel will continue to supervise that line unless changes are made at installation time. There are two methods for removing supervision alarms at the panel caused by disconnecting the second telco connection. Either method can be used. Disabling the Second Telco Connection Most fire panels have a configuration mechanism to disable the second telco connection. Once the second telco connection is disabled, the panel will no longer supervise the connection. This is the preferred method of removing supervision alarms at the panel caused by removal of the second telco connection. Connecting the Telco Connections Together The Telguard communicator is capable of providing dial tone to both telco connections, if the telco connections are connected together, such that "TIP" is connected to "TIP", and "RING" is connected to "RING". The two connections will receive dial tone in much the same way that multiple extensions in a household are connected together. If this method is used, the installer must take care to ensure that dual path reporting is not enabled on the panel, or else simultaneous alarm reports from the two telco connections may interfere with each other. TIN HTI HRI U. RINGI TIP2 I.- HT2 0 g HR2 0 RING2 To provide optimal signal conditions to the Telguard communicator, it may be necessary to boost the signal 56043601 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL * FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300'-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: TELULAR C0RP2727 Paces Ferry Rd., Ste. 1-800, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models T137G0004, TG7GFS04, and T137GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household apploication and Mode TG7GFS04 is for commercial application. Refer to listees, printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. U Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not / an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other - Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Layout E) Fastontab!187 A Faston tab 250 D .115 - O4 INCH = MM ° INCH = MM .250 6.35 I .310 7.00 .185 4.7 .250 6.35 ! ! .020 020 050 .1...004 'NP SERIES — NP7-12 'Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years of experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension ,system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gdduring noçmal use Low Maintenance Operation Due to the prfectly sealed 6onstruction and the recombination of gasses within the cell, the battery is almost maintenance free. i I Teminals / Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspehsion system allows operation in any orientation, with noloss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications Nominal Capacity (Ah) NP7-12 20hrto1 75vpc300C 7 - I 0hr to 1 .75vpc 20°C 6.4 5hr to 1 70vpc 20°C 59 1hrto1 .60'vc2(PC 4.2 Voltage 12 \ Energy iI Wi L2Ohr) 91 Specific bn i OA/h:,kg 20h0 32 \ IntReri t tiii:t 25 Maxi)uni°t iit 40/75 Short Ci rcuit current 210 Dimensions (mm) Length - 151 Width 65 Heigtove(a 97.5 Weight (Kg) 2.65 Terminal ND Layouf 4 Terminal Torque Nm - TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS: DISCHARGE CURRENT. O.17CAmp. 5P,V t.7V10ELL CHARGING CUISRENT:0,OSCMIN CHARGING VOLUME: 125% OF DISCHARGEO CAPACITY CAHIll AMBIENT TEMPERATURE. 270 TO 25'C (6FF TO TF) ROE NUMBER .1 - -- UASA iirr Vi RflPrtI Inn Distributed by 2901 Montrose Ave Laureldale, PA 1-9605 www.yuasabatteries.com Registered number 1548820 Cat. No] NP7-12 Januaiy 08 I NP SERIES — NP7-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME 9,9 ISO 17 954 0625 12S- 15 13 NP DISCHARGE CHARACTERISTICS CURVES AT 25C (779F) FOR 126 FOR 66 NM6 C Gi9.n c4pMIy 441181.4 OIl each b4Iley nM IMATTERY BATTERY 53.0 6.5 NP AT2SC(7TF) - - - - - - 12.0 f!:: :i .10 20 MINUTES DISCHARGE TIME HOURS FLOAT SERVICE LIFE NP RANGE (,"') TESTING CONDITIONS: FLOATING VOLTAGE:2.27SVPC M46NTTEwPERATUR0. 200 (687 TO 7FF) 00 so- Go- 40- CH WE (YEARS) Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge - 15°C to 50°C Discharge - 20°C to 60°C Storage - 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS 5%) 100 75- _ 201C 1 38.0 OFC(SOF CRFF) 25 3 6 9 12 IS 16 STORAGE TIME (MONThS) FLOAT CHARGE CHARACTERISTICS PH t -11 02SCA. 2275MPG CONSTANT VOLTAGE CHARGING 1%) locA) ATSOC(OVV) 145 525 1.10 05 GE060 - 16.5 100 n 7.00 CHARGECHARGEVOLTAGE 42 05 5.11 00 8.50 AFrERI00%DrO4ARGE 13,9 0,10 - AP15145514UISQIA401i 5 0,00 I 12.0 2D 5,50 ' IS 9 4 6 6 0 II 14 16 II 30 CHARGING TIME IHOIRSI SY $ 5 STEM ENsoR Photoelectric Smoke Detectors System Sensor's j3" series smoke detectors repres significant advancement in conventional detecti The ifamilyis founded on three principles: ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Installation ease. The P line redefines installation ease with its plug-in design.This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors, To complete the installation, i3 heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. i detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms.Two-wire 3 detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the 11 protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent per-foot-obscu ration. Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings & <~> 0 MEA MSFM LISTED APPROVED approved approved 5911 3011446 7272-1200.210 290-011 2093 (j)' Smoke Detector S Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 21/VT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall Include a mounting base for mounting to 31/2-Inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-8, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verifythe circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.51/ Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage - Standby Current 2-wire:50pA maximum averagè;4-wire:50pA maximum average, . Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-120°F (0°C-49°C); 2WT-B and 41/VT-B: 32°F-100°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed FreezeTrouble 21/VT-B and 4Wr-B only: 41°F (5°C) Sensitivity 2.50/a/ft. nominal Input Terminals 14-22 AWG Mounting LED Modes - LED Mode Green LED 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power Up Sequence for LED Indication Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 21/VT-B Yes 2-wire 130 mA max limited by control panel 4W-B No - . 4-wIre 20 mA @ 12V, 23mA @ 24V 4W1B - Yes 4-wire 20mA@ 12V,23mA@24V' Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter 3825 Ohio Avenue. St. Charles, IL 60174 rpc o SENSOR Phone: 800-SENSOR2 'Fax: 630-377-6495 cuffeflttInfon, including the teav!onhIs data sheet A05.0318.006. 7/06*1676 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Sysfem Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models 2W-13, 2W1-B, 4W-B and 4WT-B,photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-13 and 4W1-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listees printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 I 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Multi-Voltage Conventional Relays System Sensor's multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-1 OT/20T and R-1 4T/24T Removable front cover on steel enclosure for R-1 OE/R-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure's cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware Agency Listings @ @ 11 MEA approved LISTED The RIOT, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-1 OT is a single FORM-C (SPDT) relay with a red activation LED, and the R-1 4T is a four-gang 1 FORM-C (SPDT) relay with four red activation LEDs. The R-20T is single 2 FORM-C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM-C (DPDT) relay with four red activation LEDs. The R-1 OEIR-20E and R-1 4EIR-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure.The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a rd LED as a visible indication of relay coil energization. PR-3 is identical to PR-2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single-pole single-throw, normally-open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. EOLR-1 R-141 R-14E & R-24E Enclosure R-1 0T R-1 OE & R-20E Enclosure Multi-Voltage Conventional Relay Specifications Specifications: R-10T/R-14T/R-20T/R-24T Specifications: PR-1 Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Voltage 18-35 VDC, 18-35 VAC, 120 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, Operating Current 15 mA DC max. @24 VDC, 24VAC, 120 VAC 230 VAC (R-1 0T/R-14T) Operating Temperature -40°F to 158°F (-40°C to 70°C) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, Humidity Range 10— 93% RH 230 VAC (R-20T/R-24T) Operating Temperature -40°F to 158°F (-40°C to 70°C) Wire Length 8minimum Humidity Range 10% - 93% non-condensing Dimensions 0.87H x 2.01W x 1.42D Dimensions R-1 OT/R-201: 2.51. x 3.35W x 1.2H Contact Ratings 24 VDC: 7 A with LIR = 5 mS 120 VAC: 7 A ma (0.35 PF) R-1 4T/R-241: 101..x3.35Wx 1.2H 250 VAC: 10 A resistive Contact Ratings 24 VDC: 7Awith LJR=5 mS 30 VDC: lOAresistive 120 VAC: 10 Specifications:______________________________________ 120 VAC: 1/6 HP 230 VAC: 7 A Operating Voltage 10 to 40 VDC Specifications: R-10E/R-14E/R-20E/R-24E Operating Current 30 mA DC max. Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Temperature -40°F to 158°F (-40°C to 70°C) Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, Humidity Range 10- 93% RH 230 VAC (R-10E/R-14E) Wire Length 8'minimum 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, Dimensions 0.91 1-1 xl .65W x 1.22D 230 VAC (R20E/824E) Contact Ratings 120 VAC: 10 A max. (resistive load) Operating Temperature -40°F to 158°F (-40°C to 70°C) 120 VAC: 7 A max. (0.35 PF) Humidity Range 10% - 93% non-condensing 250 VAC: 10 A max. (resistive load) Dimensions R-1 OE/R-20E: 5.11. x 3.75W x 2.5H 30 VDC: 10 A max. (resistive load) R-14E/R-24E: 111x5.3Wx2.51-1 Specifications: EOLR-1 Contact Ratings 24 VDC: 7 A with LJR = 5 mS Operating Voltage 9 to 40 VDC 120 VAC: 10 A Operating Current 20 mA DC max. 120 VAC: 1/6 HP Operating Temperature -22°F to 140°F (-30°C to 60°C) 23O VAC: 7A Humidity Range 10- 93% RH Wire Length 8-minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30VDC: 3 A max. (resistive load) a t PR-1 PR-2 "STEM 3825 Ohio Avenue St. Charles, IL 60174 O2O07SYStflSflSO Productspd0 0 for SENSOR Phone: 800-SENSOR2. Fax: 630-377-6495 current product inforrnation, Including the latest version ofthis data sheet. A05-0372005 .3/07. #1782 CALIFORNIA DEPARTMENT OF FORESTRY& FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0103 Page 1 of I CATEGORY: 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models listed below: M500M, M5OIM;Monitor Modules M500R, M500S, M500MB; Control Modules M500C, M500CH, M502M; Control Modules M500X; Fault Isolator Module *M500DMRI; Input/Output Relay Module A2143-00; End-of-line Resistor SMB500; Surface Mount Box RMK400; Recessed Mounting Kit MB500; Module Panel C13500; Barrier Module EOLR-1; End-of-Line Supervision Relay Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Model SMB500 surface mount box may be used as an enclosure for the Model M500M monitor module, Models M500C or M500CH control module or Module M500X fault isolator module. Model A2143-00 end-of-line resistor is intended for use in the initiating circuit of the M500M and the indicating circuit of the M500C. Model RMK400 mounting kit is intended for use with separately listed compatible smoke detectors. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:104 Rev. 10-31-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I- Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PA RSEGIA N, Program Coordinator Fire Engineering Division BG-12 Series Manual Fire Alarm Pull Stations General The Fire-Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of mod- els including single- and dual-action versions. The BG-12 Series provides Fire-Lite Alarm Control Panels (FACP5), as well as other manufacturers' controls, with a man- ual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series simple to install, maintain, and operate. Features Aesthetically pleasing, highly visible design and color. Attractive contoured shape and light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (sing le- or dual-action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. The word "ACTIVATED" appears on top of the handle in bright yellow, further indicating operation of the station. Operation handle features white arrows showing basic opera- tion direction for non-English-speaking persons. Braille text included on finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patented hex-lock needs only a quarter-turn to lock! unlock. Station can be opened for inspection and maintenance with- out initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head captive 8/32 screws for easy connection to Initiating Device Circuit (IDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm2). Terminal numbers are molded into the backplate, eliminating the need for labels. Switch contacts are normally open. Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by 1/2° (1.27 cm). Optional trim ring (BG12TR). Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP). Designed to replace the Fire-Lite legacy BG-10 Series. Models packaged in attractive, clear plastic (PVC), clam- shell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. DF-52004:A1 • F-050 LuTetALarn1S by ey-we Construction Cover, backplate and operation handle are all molded of durable polycarbonate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlert® •Advance horn/strobe series. Operation The BG-12 manual pull stations provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the sta- tion, provided for non-English-speaking people. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. DF-52004:AI • 04/22/08 - Page 1 of 2 Specifications PHYSICAL SPECIFICATIONS: pull station SB-1/0 SB-10 Height 5.5 inches 5.601 inches 5.5 inches (13.97 cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches (10.47 cm) (10.72 cm) (10.47 cm) Depth 1.39 inches 1.439 inches 1.375 inches (3.53 cm) (3.66 cm) (3.49 cm) 52004d1m.tbl ELECTRICAL SPECIFICATIONS: Switch contact ratings: gold-plated; rating 0.25 A © 30 VAC or VDC. ENGINEERING/ARCHITECTURAL SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. NOTE: *The words "FIRE/FUEGO" on the BG-I2LSP shall appear on the front of the station in white letters, approximately 3/4' (1.905 cm) high. Agency Listings and Approvals The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. C(UL)US:S711 FM Approved CSFM: 7150-0075:184 MEA: 67-02-E Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Product Line Information BG-12S: Single-action pull station with pigtail connections, hex lock. BG-12SL: Same as BG-12 with key lock. BG-12: Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock BG-12L: Same as BG-12 with key lock BG-12LSP: Same as BG-12L with English/Spanish (FIRE! FUEGO) labeling. BG-12LOB: Same as BG-12L with "outdoor use" listing. Includes outdoor listed backbox, and sealing gasket. BG-12L0: Same as BG-12L with 'outdoor use" listing. Does not include backbox. BG-12LA: Same as BG-1 2L with auxiliary contacts. BG-12LPS: Dual-action pull station with pre-signal option. BG-112LPSP: Same as BG-12LPS with English/Spanish (FIRE! FUEGO) labeling. SB-b: Surface-mount backbox, metal. SB-I/O: Surface-mount backbox, plastic. (Included with BG- 12LOB.) BG12TR: Optional trim ring for semi-flush mounting. 17003: Keys, set of two. (Included with key-lock pull stations.) 17007: Hex lock, 9/64". (Included with hex-lock pull stations.) NOTE: For addressable BG-I2LX models, see data sheet DF- 520 13. Fire-Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. 93=033= We cannot cover all specific applications or anticipate all requirements. ENGINEERING &MIINQFACThRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52004:A1 • 04/22/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian. Reynolds2Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-I2LW, BG-I2WP, BG-I2LWP, BG-12L, BG-I2LX, BG-I2LA, BG-I2PS, BG-I2LSP, BG-I2SP, BG-I2LR, BG-I2LRA, BG-I2LAO, BGI2LAOB, BG-12-LO, BG-I2LOB, BG-I2LPS, BG-I2LPSP, BG-I2SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-I0 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-I 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 ) S *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not •j an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Models Available Standard Application Models 2100S 21001S 2112/24S 2112/241S Auxiliary Form C Relay Models 2100TR 2112/24R 2112/24TR Temporal Pattern Sounder Models 2100AT 2112/24A1 2112/24ATR 2112/24AITR Product Overview Full product line of photoelectric, System Sensor's 100 Series smoke detectors may come in a small package low-profile smoke detectors but they pack some big benefits. A large, supervised terminal block (patent pending) featuring captured SEMS screws simplifies installation. SmartCheckTm diagnostics let you visually check sensitivity range SmartCheckTM self-diagnostics allow you to check the detector's sensitivity Isolated thermal models range by simply looking at the unit. Every ten seconds diagnostic circuitry monitors chamber sensitivity, checking to see if the detector is within its UL Extensive two-wire compatibility specification range. If it is, the LED flashes every ten seconds. If not, the LED listings stops flashing - a clear sign the detector needs cleaning or servicing. So, to "Twist-off" cleaning on standard see if a 100 series is within specification range, just look at it. This meets models only NFPA 72 requirements for sensitivity testing. For sensitivity readout, use MOD Sounder units feature built-in 400 accessory and voltmeter. temporal tone Heat Detection. Integrated thermal models provide restorable, 135-degree Auxiliary Form C Relay units fixed-temperature heat detection. Isolated thermal models feature a fixed-tern- control elevator recall,. door closure perature heat sensor that is isolated from the smoke sensor, providing a self-resetting, local audible smoke alarm. In these models only the isolated heat sensor will signal an alarm to the panel. The isolated thermal products are designed for applications where local annunciation, not total facility evacuation is desired. Sounder Models. A built-in piezoelectric horn (patent pending) in the 100 series sounder models produces the NFPA 72-required, 85dBA temporal UL tone pattern when the individual detector alarms or when the supply voltage polarity is reversed. LISTED continued System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor- Far East 3825 Ohio Avenue Ph: 905.812.0767 Ph: 011.86.29.524.6253 Ph: 011,852.21919003 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 011.86.29.524.6259 Fx: 011.852.27366580 Ph: 800-SENSOR2 S Fx: 630/377-6495 System Sensor in Europe System Sensor in Singapore System Sensor- Australia Ph: 011.44.1403.276500 Ph: 011.65.273.2230 Ph: 011.613.54.281.142 Fx: 011.44.1403.276501 Fx: 311.65.273.2610 Fx: 011.613.54.281.172 1999 System Sensor The company reserves the right to change product specifications without notice. A05-227-09° 1/99(25K) 4400 Standard. Application Specifications S Operating Voltage Fixed Temperature . 12/24 VDC (nominal), 8.5 mm. to 35 max. Heat Sensor Standby Current 135°F electronic thermistor • 50 pA maximum average Diameter . — Humidity Range . 5.5 in. (140mm) 10% to 93% RH. noncondensing . S Height .. .. . 1.9 in. (48mm) with bracket Weight 5.3 oz. (150 grams) Model . Wiring I Temperature Range .., . .Alarhi Current . .. . . 21 DOS: No 2-wire 32° to 120°F (0° to 50°C) lOOrnAmax. limited by panel 210015 . . .Thermal Yes 2-wire 32° to 100°F (0° to 38°C) .. lOOmA max. limited by panel 2112/24S . No . 4-wire 32° to 120°F (0° to 50°C) 17m-Atypical, 23mA max.. at 12V; 19mA typical, 25mA max. at 24V 2112/24T5 Yes 4-wire. 32 to 100T (0 to 38 C) 17mA typical 23mA max at 12V 1 9m typical,.25mA max at 24V Auxiliary Form C Relay Specifications Auxiliary Cdntact . Humidity Range ........... . . . Height Form C . . . . . . 10% to 93% RH.:noncondensing . .. 1.7 inches (43mm) with bracket . Auxiliary. Relay Contirt Ratings Diameter Shipping Weight 1A@30 .VDC; . . . 5.5 inches (140mm) :: . . 6.8 ounces (192 rms) . . 5. 5 5 . 5 . .s , 5 . 5. 1 •.. . Fixed Temperature. Model . Thermal Wiring Temperature Range Operating Vojtàe• Heat Sensor . Alarm Current Standby. Current 2100TR* Yes 2-wire. 32 to 100 F 2/24 VDC (nominal) 135 F lOOmA max 50 IJA average (Do to 38'C) 8 5 min. to 35 max electronic thermistor limited by panel 100 pA maximum 2112/24R* No 4-wire 32°:to 120°F . 12/24 VDC (nominal) — 28mAtypical . 50 pA average (0° to 50°C) 10 mm. to 35 max. . . 35mA max. at 12V 5 5 . 36mA typical . . 45mA max. at 24V 2112/241R* . Yes 4-wire 32° to 100°F 12/24 VDC (nominal) 135°F 28mA typical 50 pA average (0° to 38°C) 10 mm. to 35 max. electrOnic thermistor 35mA max. at 12V 36mA typical 45mA max. at 24V Temporal Pattern Sounder Specifications Standby Current Fixed Temperature Heat Sensor Height 50 pA avg.. 100 pA max. 135F electronic thermistor 2.05 in. (52mm) with bracket Temperature Range Diameter Shipping Weight 32°-100°1` (0°-38'C) 5.5 in. (140mm) . 7.4 oz. (210 grams) Humidity Range 10%-93% RH. noncondensing 5 5 Auxiliary . Built-In Temp 3 Auxiliary Model. Thermal Wiring Operating Voltage Alarm Current Consumption Contact Ratings Sounder Contact 2100AT* Yes 2-wire 12/24 VDC 13mA mm., lOOmA max. — 85dBA No 8.5 mm. to 35 max. 2112/24A1 Yes 4-wire 12/24 VDC 49mA typical, 60mA max. at 12V — 85dBA No 10 mm. to 35 max. 57mA typical, 65mA max. at 24V - 2112/24ATR* Yes 4-wire 12/24 VDC 49mA typical, 60mA max. at 12V 1A@30 VDC 85dBA Form C 10 mm. to 35 max. 57mA typical, 65mA max. at 24V 2112/24AlTR* Isolated 4-wire 12/24 VDC 49mA typical, 60mA max. at 12V 1A@30 VDC 85dBA Form C 10 mm. to 35 max. 57mA typical, 65mA max. at 24V CSFM, MSFM listed System Sensor Sales and Service CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE. STATE FIRE MARSHAL . . . . . . . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM .. . . . LISTING SERVICE. . LISTING No. . 7272-1209:187 Page 1 of 1 CATEGORY Photoelectric Smoke Detector LISTEE: . . System Sensor, 3825 Ohio Ave., St. Charles IL, 60174 . .:. Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245 . .: ••. .. .• . DESIGN Models 2100S 2IOOTS 2112/24S and 2112/24T5 photoelectric type smoke detectors Models 2100S and 2I00TS are 2-wire smoke detectors. Models 2112/248 and .•.. 2112/2418 are 4-wire smoke detectors. Models 2IOOTS and 2112/24T5 employ a supplemental thermistor type heat sensor Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING 85-32 VDC INSTALLATION: . . In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling Mount. . . . . . . . U MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-3000 ft/mm. *Rev. 06-16-2003 TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not in endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy k-e V Pm gram Manager 1-~rvn To: DIANA From: GE ItTERLOGIX INC. 2-26-04 9:41am p2 of: 3 MEL NOW and into the Future Cailtornia State. Fir.. M*rshai APprovid tu Patented FEATURES UL 268 Listed a Alarm confirmation Powerlalarm Indicator LED Low current Consumption Functional test Tamper resistant hinged cover Integral heat sensor (optional) Auxiliary alarm contacts (optlànai) RFI and line transient protection I ELECTRICAL SPECIFICATIONS SMOKE DETECTORS—All Models Standby Voltage* 115-33 VDC or VFWR Standby Current 40 A 0 12 V. 100 pA @ 24 V Alarm Voltage * 8.5-33 VDC or VFWR Alarm Current 15 mA 0 12 V. 30 mA @ 24 V Contact Rating (resistive) Models 445C, 445Cr - I Ampere @ 30 VDC or 120 VAC Models 445CR. 445CRT - 2 Amperes @ 30 VDC or 120 VAC POWER SUPERVISION UNITS 'MODEL 204A MODEL 204C Operating Voltage 5 .. 5.1-19.8 VOC: 14-33 VDC Operating Current' 40 mA @ 12 V'lO mA @ 24 V Contact Rating (resistive) • I Ampere @ 30 VDC or 120 VAC VDC —Filtered DC, 10% Ripple Maximum VFWR—Untiftered Full Wave Rectified 4415C1ERIES, PHOTOELECTRONIC SMOKE DETECTORS DESCRIPTION The 445C Series are four-wirephotoelactronic smoke detectors that operate on the light scattering concept A pulsed infrared light emitting diode is used as the light source and a high speed photodlode as the sensing element Each unit has one Form A (SPST-NO) alarm relay contact for connection to an alarm initiating ciicuit. An additional alarm relay contact set (Form C SPOT) for auxiliary functions and/oran Integral heat sensor (1350F, 50 ft.) are available asdptions. See Electrical Specifications. APPLICATION . •:. •. The 4450 Series smoke detectors are suited for commercial industrial Institutional and residential tire alarm systems The detector is intended for four-wireconnection to UL Listed 12 and 24 volt DC tire alarm control units. All models are easily converted to non-latching operation. Those equipped with auxiliary alarm contacts are. also suitable for releasing service. INSTALLATION The 4450 Series smoke detectors mount to standard single- gang electrical boxes, 4" octagonal electrical boxes, or on WIREMOLD No. 5739 fixture boxes, All field wiring connections are made to a terminal block on the printed circuit board. This area is accessed by depressing the cover release tab and opening the hinged cover, System wiring easily fits thrOugh the opening in the back of the smoke detector. A field "knock out" area is provided for use when power limited surface wiring is used. APPROVALS The smoke detector is for use in commercial lire protective signaling systems (NFPA 71, 72A, 728, 72C, or 72D) and in household tire warning systems (NFPA 74). Listed by Underwriters Laboratories, Inc.; California State Fire Marshal approved (Listing #7257.447:104); Factory Mutual approved (J.l.OK789.AY); State of Maryland approved (Permit #1885); City of Cleveland approved (Docket S-5.88); New York City, Board of Standards and Appeals approved (Calendar No. 122.73.SA). MODEL DESCRIPTION 445C smoke detector 445C1 smoke detector with 135°F, 50 ft. heat sensor 445CR smoke detector with extra Form C alarm contact set 445CAT smoke detector with extra Form C alarm contact set and 1350l 50 ft. heat sensor 204A power supervision unit for 12 VDC systems 204C I power supervision unit for 24 VDC systems Area .Wpe, 10 VDC-30VDC FOur Wire .. To: DIANA PHOTOELECTRoNIC SMOKE DETECTORS FEels: GE INTERMIX INC. 2-26-04 9:41am P. 3 of 3 I WIRING CONNECTIONS Screw terminal modeft 445C models 445CR enlargement for dutiI and 445CT and 445CR7 - alarm first contacts power alarm contacts power deiscior. . '\ f . . . . -• . detector .. - . . .11 LAE I 4 3 2 LISTED . S CONTROL . . . UNIT red . -- oc •+ POWER . s- . SUPERVISION -power - • . - - . . . . black UNIT circuit - _____________ ________________ . •—.-4 . brown brown Warm I . .. - • initiating.. •, :. -• . . . . circuit I - END OF LINE DEVICE Emergency operation IStyle D (Class A) Return Initialing circuit wiring to appropriate control unit terminals and connect the end of line devices per the control unit instructions CAUTION DO NOT use looped wire under screw terminals These terminals are designed to prevent looping of unbroken wire around or under a terminal screw in a manner that would permit the looped wire to remain unbroken during installation- This would preclude supervision if the wire were to dislodge from the terminal. . PRODUCT DATA SENSITIVITY 3.1 ± 0.500/b/Ft. OPERATING TEMPERATURE RANGE 32°F to 120°F 0°C to 50°C OPERATING HUMIDITY RANGE 0 to 95% RH.. DETECTOR SIZE diameter 6.1 In. 15,5 cm height 2.0 in. 5.0 cm weight 1 8.8 oz. 0.25 kg PACKAGING 20 detectors are paOked In a carton SMOKE DETECTOR SPACING On smooth ceilings (as defined In NFPA 72E), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, arid other conditions or response requirements. -, 5L ELECTRO SIGNAL LAO, INC. 75 Terry Drive. Hingham. MA 0204 Sales 1-800-225-8632 Literature 1-800-648-7423 NOWand into the Future Inside Massachusetts 617.740.3800 Bulletin 2283-SS4 March 1989 Annwaran.-,.a mnii rlaftlla eiihlai-t Sn rh2nna withn,t SPECIFICATIONS . The smoke detectors shall be model 4450 ( ) and shall operate on the photoelectronic light-scattering principle. The detectors shall be Listed by Underwriters Laboratories, Inc. The smoke detector shall contain an infrared LED light source and a light sensing photodiode. These components shall be positioned such that when smoke particles enter the sensing area, light from the LED reflects onto the photo- diode. When the amount of light reflected onto the photo- diode reaches the sensitivity setting, the smoke sampling rate shall increase to twice (2x) normal. The alarm signal shall be confirmed by requiring three (3) successive smoke sensings above the sensitivity, setting. Detector alarm shall occur only alter confirmation and Will cause the normally flashing power indicator LED to light continuously and the alarm relay to operate. The detectors shalt be capable of latching or non-latching alarm functions. The detectors shall be non-polar and shall provide an easily operated full-functional field test. The detectors shall be equipped with an integral 135°F (57°C) (50 loot Rated) heat sensor (optional on models 445C1 and 445CRT). The detectors shall be a single part with a hinged cover and Include a concealed tamper-resistant latch. The detector shall include insect screens. All wiring terminations shall be to clamp-type screw terminals protected by a terminal block cover. The smoke detector shall mount to a standard single-gang electrical box, a 41 octagonal electrical box, or WIFIEMOLD No. 5739 fixture box. . . . . . . Distributed by: . ENTEX 4" Electro-Mechanical SERIES Horn/Strobe Available in Weatherproof Applications 4' low frequency electro-mechanical horn and horn/strobe series that meets and exceeds code requirements for supervised fire alarm systems for the hearing impaired. The GMH/GMS Series are quality elec- tro-mechanical signaling appliances that offer you both dependable evacuation sig- nals and visual alarms by means of simple screw terminal wiring connections. The GMH/GMS Series are designed to be used for both new construction and retrofit projects. With the Gentex trim Standard Features Low Frequency Penetrating Sound Output Low Operating Current Screw Terminals, Separate In/Out Field Wiring (12 Gauge) Separate Horn and Strobe Functions (Jumper Wires) Xenon Strobe Maintains Constant Flash Rate (1 Hz) Regardless of Input Voltage AvilihIA MoriRis ring the GMH/GMS can be mounted to a double gang work box in retrofit or new construction. The GMH/GMS are suited for areas having high ambient noise levels where higher audible output is required. The Z- Series synchronized strobes require the use of the ZMS4 module. The GMH/GMS appliances are UL 464 and UL 1971 listed for use with fire protec- tive signaling systems and are warranted for 2 years from the date of purchase. No Mechanical Contacts Textured Plastic High Impact Red Faceplate Supplied with Beauty Plugs to Accommodate Mounting Option Variety of Standard Mounting Options To Synchronize Use the Z Model with the Gentex ZMS4 Control Module Outdoor Use Listed (GMH and WGMS) GMH-24 GMS-24 Approvals MEMBER U.S.A. TNS symbol on the producTs nameplate means II IS Lleted by UNDEthWRJTESS LABORATORIES. INC. Americans with Disabilities Act (ADA 4.28.3) BFP (City of Chicago) BS&NMEA #285-91-E Vol. VII CSFM #7135-569:119 NFPA72 UL464& UL 197111638 15/75, 30/75 and 110 Candela Strobe Options Meet or Exceed the Requirements of ADA 4.28.3 UL 464/UL 1971 Listed for Fire Protective Service/Signal for Hearing Impaired Light STROBE RATED CURRENT @24 VOC In UL Rever- Effective In Anechoic berant Room Model Nominal Intensity in Horn Room dBA @ 10 Ft. Number Voltage Candela Current Nominal Start-Up Peak dBA @10 Ft. Per UL 464 GMH24 24 VDC - 38mA - - - 95 85 GMS24-15 24 VDC 15 38mA 78mA 114mA 84mA 95 85 GMS24-15175-W 24 VDC 15 (UL 1971) 38mA 93mA 130mA liOniA 95 85 75 (UL 1638) GMS24-15/75-C 24 VDC 15 (UL 1971) 38mA 115mA 140mA 120mA 95 85 75 (UL 1638) GMS24-15175-Z 24 VDC 15 (UL 1971) 38mA 130mA 490mA 680mA 95 85 75 (UL 1638) GMS24-30 24 VDC 30 38mA 93mA 130mA ilOmA 95 85 GMS24-30/75 24 VDC 30 (UL 1971) 38mA 142mA 120mA 160rnA 95 85 75 (UL _1638) GMS24-60 24 VDC 60 38mA 11 5m 140mA 120mA 95 85 GMS24-110 24 VDC 110 38mA 220mA 148mA 240mA 95 85 WGMS4-75 24 VDC 75 (UL 1638) 38mA 105mA 130mA ilOmA 95 85 Note: All 24 VDC models operate from 21-30 VDC -20 +10% Operating temperature Indoor: 32° to 120°F 0° to 49°C Outdoor: -31° to 150°F -35° to 66°C WHEN PLACING AN ORDER: add the following to the end of the model number: Wall mount "C" = Ceiling mount (15/75,30/75 and 75 models only) "P° = Plain (no lettering) 77 = Synchronized strobe (15/75 wall models only) J GENTEX SERIES Wiring Diagrams GMH HORN AND GMS SERIES POWERED IN PARALLEL II IP!'tL J H. H. S. S. I Fl. H. S. S. I ls,rv&sI _ 1 00 ____ Isoerk IL 1II 1EOLR GMS SERIES WITH HORN AND STROBE POWERED INDEPENDENTLY. NOTE: CUT JUMPERS 1 AND 2, SEE FIG. 3. a um SUPERVISED It Iu uIIIlI uIII 0 i ••i EOLR NOTE: POWER IS SUPPLIED TO DEVICES WHEN CONTROL PANEL IS LATCHED. Dimensions 0.938 4.531 - \ 7 Mounting: 4" square boxes wlbrackets 1 1/2 deep minimum 4" square metal/non-metallic switch/outlet boxes 1 1/2" deep minimum Gangable 2 gang switch/masonry outlet boxes 1 1/2 deep minimum (with trim plate) WGBB Gentex weatherproof back box NOTE: Supplied with beauty plugs to accommodate a variety of installations. GENTEX CORPORATION Fire Protection Products: www.gentex.com 10985 Chicago Dr., Box 310, Zeeland, Ml 49464 616/392-7195 1-800/436-8391 FAX: 616/392-4219 Gentex corporation reserves the right to make changes to the product data sheets at their dscretion. Architect & Engineering Specifications The audible or audible/visual signal shall be Gentex model GMH or GMS or approved equal, and shall be listed by Underwriters Laboratories per UL 464, and when combined with the strobe option the strobe shall also be listed per UL 1971. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance shall produce a peak sound output of 105dBA or greater as measured in an anechoic chamber. The visual signal shall have a flash rate of 1Hz regardless of input voltage. The notification appliance shall be provided with screw terminals for in and out field wiring and the strobe shall be capable of operating independently after the audible has been silenced. The notification appliance shall be capable of mounting to a 4" square back box and a 2 gang switch box with the Gentex trim ring. 12 units per carton 19 pounds per carton GMH 20 pounds per carton GMS QP Printed on Recycled Paper GX061394-12 CI4JJFOF%IA DEP/RrIVErW OF FCS1RV & FIRE PRO1EC1101Y OFFICE CF TI-E STATE FIRE M4F514AL HRE ENGINEERING - JLIJING MATERIALS LISTING PROGRAM LISTING SERVICE US11NGI\b. 7135-0569:119 Page 1 of 1 CATEGORY- tucthle Devices LJSIL±: Cntex Corporation, 10985 Chicago D., Zeeland M 49464 Contact: Lisa Lantz (616) 392-7195 DESIGN Model GM-I-24 hail and Models G1V&24-15, GV&24-15'75, *Gv&24..30, GEV&24- 30/75, GV&24-60', \MW&24-75 and GIVS-24-110 horn stidjes. tilts rray be fdlai.aJ by suffix -P (Jain), -Wcr -C (v.ell or ceiling), -Wcr-R (vAlte or red), arxi/cr-Z (ynchulzed strobe). Refer to listee's data sheet for acklticrnl pockil description and operational ccrthatia. RA11NG: Electrical: 24Vt)C candela: -15:15cd;-1a/75:15cd and 75cda(Yajeaxis -3CY 30d; -30/75: 30 cd and 75 Cd at (Y a-ge axis -60: 60od; -75: 75 Cd; -110: 110 cd Flash rate 60 flashes per minute INSTALLATION and in a manner acceptable to ttu authority haNAngjLrisdiction. MARKING: Listee's rerre, model w-rber, electrical/candela ratings and LL label. JPPRC7tLSL: Listed as horn and horn strobes for use nAth separately listed ccrrpaft1e fire alarm control units. tilts vAth strobe Iiq-it are suitable for the hearing in-ired applications except for Model WEV&4-75. lVbdel VGV6475 is intended for ganeral signaling use and not suitable for the hearing in-paired application. Mxbls GV1424 hcm and \AGV&4-75 haii strobe maybe use for alcbcr vAi€n installed wth Mxkl 3014 or 3015 v.eethapDof back box. JJI other triits are for ir±xr use only. If this appliance is reqi red to produce a distinctive three-pulse Temporal Pattern Fire P.larm Evacuation Si" (for total ecieticn) in accordance vAth NFPA 72, 1993 Edition, the appliance rrwt be used vAth a fire alarm control unit fret can gererate the terrporal pattern signal . Refer to rmrufactuer=s Installation Nitirial for details. *Rev. 06-27-97 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 7 06- recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation .. criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Cate Issued MAY 17, 2001 Listing Expires June 30, 2002 'l Authorized By: BEN HO, Supervising Deputy Program Manager U 2.20 DON'T SEE IT? CALL 1-888-423-8947 SEC1ION2 Fl RE ALARM CABLE J PART NUMBER I AWG CONDUCTOR I SHIELDED! OVERALL I 1 UNSHIELDED DIAMETER C CONDUCTOR COLOR JACKET COLOR VOLTAGE RATING WEIGHT (Ibs)I1Jnit MARKINGS TEMP PUT UPS .1 I BLACK, WHITE, WHITE 300v I 18.0 I AOl 494469 I 600c 500 RED GREEN LBS 12IC22AWG REEL BROWN, BLUE, TYPE FPLP/ ORANGE, YELLOW, Cmp VIOLET, GRAY, PINK, IAN rBLACK,RED RED 16.0 AOl 493490 75°C k,1000 LBS 2/CI8AWG BOX TYPE FPLP/ CMP YL (UL) 8.0 AOl 493490 500 LBS 2/C18AWG BOX TYPE FPLPI CMP (UL) LIGHT BLUE, 16.0 A0T493493 YELLOW LBS TYPE FPLPI CMP (UL) 60°CH BOX 8.0 ADT LBS 2/C18AWG TYPE FPLP/ CMP (UL) ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 2.21 (_ ' p SECTION2 FIRE ALARM CABLE I !ART NUMBER - AWG SHIELDED! OVERALL UNSHIELDED DIAMETER Ic0t4T0R I COLOR I CONDUCTOR I JACKET COLOR VOLTAGE RATING I WEIGHT (Ibs)/Unit I MARKINGS TEMP PUT I [ UPS I BLACK. RED, RED 300v 16.0 ADT 494449" 70°C 500 LIGHT BLUE, LBS 4/C18AWG REEL YELLOW TYPE FPLP/ CMP (UL) BLACK, RED, 26.0 CMP/FPLP 16/4C BROWN, BLUE LBS (UL) nul \ZV 16AWG WHITE 36.0 ADT 493496 BLACK' RED. LBS 1PR16AWG 19AWG IPR19AWG LIGHT BLUE/ TYPE FPLP/ YELLOW CMP (UL) RED ADT 493498 1000 1 PR. ' 16AWG REEL 1 PRI9AWG TYPE FPLP/ CMP(UL) 18.0 ADT 493498 500 LBS 1 PR 16AWG REEL 1PR19AWG,,-. TYPE FPLP/ $i) CMP(UL) DON'T SEE IT? CALL 1-888-423-8947 ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 2.22 !•J I 2.23 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1295:0100 Page 1. of I CATEGORY: 7161-- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: DESIGN: Comtran Cable, LLC.330A Turner Street, South Attleboro, MA 02703-7714 Contact: Bruce Lamoureux (508) 399-7004 Ext: 245 Fax (508) 399-7360 Email: Bruce.Lamoureux©comtrancorp.com Types FPL, FPLR and FPLF. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes, NEC Article 760 and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. 6-16-10 MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PA RSEGIA N, Program Coordinator Fire Engineering Division III