HomeMy WebLinkAbout2310 CAMINO VIDA ROBLE; ; FA120009; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120009 2310 CAMINO VIDA Job Address: ROBLE Permit Type: FALARM Parcel No: 2130500800 Lot #: 0 Status: APPROVED Applied 2/8/2012 Approved: 2/23/2012 Reference No.: Issued: 2/23/2012 PC #: Inspector: Project Title: NORTH COAST CHURCH FIRE ALARM SYSTEM Applicant: Owner: JJJ ENTERPRISES R J VIDA ROBLE INVESTORS L L C 533 S VINEWOOD ST 2333 STATE ST #200 ESCONDIDO CA CARLSBAD CA 760-747-3050 Fees ($) Add'l Fees ($) Total ($) Balance ($) 488 0 488 0 LE COP' NFIRP141 EHVERPRnEa FIRE ALARM - SECURITY LOW VOLTAGE SYSTEMS North Coast Church 2310 Camino Vida Roble Carlsbad, CA Fire Alarm System Material Data Submittal I 7e ii ui i'p c iIc. '' - 'Ii( s'r poI i 'lcrn,tot j1 i' eri -r,j tlr, cr cu555-.5( us, sir Pr "'laI ,,, "'cr Issj usle rsp I'll. 111jil, toll II, csrd issi1j csssj, or for repohh,I, o fLfl( rcn,es ci',, • I Ig!, , n 11 Io, 01 sir If,, Ics ci, 0 RL( IMNg) * At'RQ\ L1E COPY North Coast Church 2310 Camino Vida Roble Carlsbad, CA Fire Alarm System Bill of Materials NOTIFIER NFV-25/50 EMERGENCY VOICE EVACUATION CONTROL PANEL CSFM# 6911-0028.0229 WHEELOCK E90-MCC-FR CEILING MOUNT SPEAKER/STROBE COMBINATION CSFM# 7125-0785:0152 WHEELOCK STRC CEILING STROBES CSFM# 7125-0785:0168 WHEELOCK RSSWP-2475W-FR WEATHERPROOF STROBES CSFM# 7300-0785:0154 DN-7004:A1 •C-10 (a NOTIFIER® Voice Evacuation Control Panel by Honeywell General N FV-25/50 FireVoice-25/50 The FireVoice-25/50 (NFV-25/50) is a state-of-the-art, single- or dual-circuit (25 watts each) Emergency Voice Evacuation Control Panel (EVAC). The NFV-25/50 records five field-pro- grammable messages (up to 60 seconds total message dura- tion) with an integral commercial-grade emergency communications microphone or from an external audio source. Significant technological enhancements set the NFV-25/50 apart from other EVAC panels - these include full supervision in both active (alarm or music) and standby conditions, super- vision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power sup-. ply charges up to 18 AH batteries, which can be housed in the NFV-25/50 cabinet. The NFV-25/50 is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACP5). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts (providing dual 25- watt speaker circuits) or as a secondary amplifier in jurisdic- tions requiring backup. A 70.7 VRMS converter is also avail- able for independently converting amplifiers to meet retrofit needs. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, non- fire, multi-language, etc.) make the NFV-25/50 the most versa- tile voice evacuation system available. Suitable Applications include schools, auditoriums, dormito- ries, theatres, restaurants, places of worship, lodging, office buildings, and factories. Standard Features Listed to UL Standard 864, 9th edition. Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style V (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). Modular design for maximum system flexibility pnd ease of service. . . Five Command Input Circuits (CMD) are available fdràti- vation by an FACP. Two command input circuits can be independently field-prcY~ grammed for activation by a Notification Appliance Circuit (NAC) or contact closure. Three command input circuits activate on contact closure. Manual deactivation of speaker zones. Command inputs allow: - One 60-second message. - Two 30-second messages. - Three 20-second messages. - Four 15-second messages. - Five 12-second messages. Microphone time-out feature. Nineteen different system and diagnostic LEDs. Two Form-C trouble relays (System & AC Power Loss). Optional equipment: second amplifier; local playback speaker; and remote microphone. Integral digital message generator with standard, factory prerecorded emergency evacuation message. Custom messages are field recordable, using the integral microphone or the audio input jack. Digital message may be field-selected to- 3, 4, 6, 8, or infi- nite repeat. Built-in alert tone generators with steady, slow whoop, high/ low, or chime tone capability. Field-selectable lead-in/trailing tone selection. Alert tone selection may be field-programmed to conform with ANSI S3.41 Audible Emergency Evacuation Signal (Temporal Pattern), per NFPA Speaker zone control via CMD inputs or <eypad. Dual-optically-isolated, trigger input circuits are indepen- dently field-programmable for activation by polarity reversal (host FACP NAC) or dry-contact closure. Zone 1 switch-programmable for All-Call operation. Integral diagnostic LEDs inc ude: Power, System Trouble, Microphone Trouble, Message Generator Trouble, Tone Generator Trouble, Amplifier Fault, and cthers. Independent Form-C trouble relay allows FACP to monitor voice system while in active (alarm) state. Integral piezo provides local audible indication for troubles. Fully supervised in Standby and Active states, including integral microphone, amplifier output, message generator, speaker wiring, and tone generators. Independent amplifier supervision: current limit, audio level, short circuit protection. All outputs are power-limited. Auxiliary power output provices local power for addressable control modules when used to activate the NFV-25/50. Compatible with all NOTIFER FACPs, as well as other manufacturers' panels. Background music capability (requires AHJ approval). When using the background music option, total output power per amplifier is reduced to 20 wafts. DN-7004:A1 • 1/13/10 -- Page 1 of 4 Optional Modules ACC-AAM25: 25. watt, 25 VRMS audio amplifier module. Field-programmable for system expansion to 50 watts (provid- ing dual 25-watt speaker circuits) or as a backup to the primary 25-watt amplifier where required. Single Class A or Class B speaker circuit. Plug-in-style terminal blocks for ease of ser- vice and maintenance. Fully supervised and power-limited. Diagnostic LEDs include: yellow "trouble" LED (cable fault, 70 VRMS fault, amp fault) and green "amp functional" LED. FC-XRM70: Converts 25 VRMS audio outputs to 70.7 VRMS for retrofit applications. Plugs directly on ACC-AAM25 mod- ule(s), allowing independent conversion to 70.7 VRMS. FC-LPS: Local digital message playback for user review of field-recorded custom messages. BAT Series: Two batteries required. See FACP manual for specific current requirements. See data sheet for overview of batteries. NFV-TR: Optional trim ring for semi-flush mounting. VEC-RM: Optional remote microphone, includes backbox. Only one VEC-RMper system. Specifications Command input circuits (CMD1 and CMD2): Trigger input voltage: 10.5 —29 VDC. NOTE: When programmed for reverse-polarity activation. Trouble contact rating: 2.0 A at 30 VDC (resistive), 0.6 A'@ 125 VAC (resistive). Auxiliary power output: Specific application power: 24 V, 35 mA. Primary (AC) power: 1.6 A maximum @ 120 VAC, 50/60 Hz. Secondary power (battery) charging circuit: Supports lead- acid batteries only. Float-charge voltage: 27.6 V. Maximum charge current: 800 mA. Maximum battery charging capacity: 18 AH. Cabinet Specifications Door: 26.174' (66.482 cm) high x 15.780" (40.081 cm) wide x 1.125" (2.858 cm) deep. Backbox: 26.0" (66.040 cm) high x 15.5" (39.370 cm) wide x 4.75" (12.065 cm) deep, depth includes door. Controls and Indicators LED INDICATORS Power On (green). System Trouble (yellow). Message Generator Trouble (yellow). Tone Generator Trouble (yellow). Microphone Trouble (yellow). Record/Playback (green). Zone 1 (green = Active, yellow = Manual Deactivation). Zone 2 (green = Active, yellow = Manual Deactivation). Other system LEDs: Battery Trouble, Charger Trouble, Ground Fault, Speaker Circuit Trouble, and Amplifier Supervisory. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F Standards and Codes The NFV-25/50 complies with the following standards: NFPA 72 National Fire Alarm Code; NFPA 101 Life Safety Code; UL 864 Standard for Control Units for Fire Alarm Systems. Listings and Approvals These listings and approvals apply to the basic NFV-25/50. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635 (Standard 864 9th Edition) CSFM: 6911-0028:229 MEA: 341-03-E Vol 2 (NFV-25/50, ACC-AAM25) Product Line Information NFV-25/50: 25 watt, 25 VRMS, Emergency Voice Evacuation Control Panel with integral commercial microphone, digital message generator, and single-/dual channel Class A or Class B speaker circuits. ACC-AAM25: Optional 25 watt, 25 VRMS Audio Amplifier Module with single Class A or Class B speaker circuit. FC-XRM70: optional 70.7 VRMS Converter Module (one required per amplifier). FC-LPS: optional Local Playback Speaker. BAT Series: Two batteries required. See FACP manual for specific current requirements. See data sheet for overview of batteries. NFV-TR: Optional trim ring for semi-flush mounting. VEC-RM: Optional remote microphone, includes backbox. Only one VEC-RMper system. Application Examples The FireVoice-25/50 is a voice evacuation control panel which can be used with a variety of FACPs for emergency audio messages. Two typical application examples follow. One Speaker Circuit Single output zone, single input circuit (SEE FIGURE 1). A very basic application is one NFV-25/50 with one amplifier and asi/tgle speaker circuit. This configuration is suitable for small fbiIitiOs requiring no more than 25 watts of output power. A irigle fire evacuation message will be initiated during an alarm condition from the host FACP or can be manually started with a message push-button. The NAC from the host FACP is connected to CMD1. The CMD1 "out" terminals are then terminated with an end-of-line resistor for the FACP's Style Y NAC, or the terminals are wired back to the host FACP for a Style Z NAC. S3 DIP switches "1", "2", and "3" are set to OFF; this selection sends a 60-second message to the speaker circuit when the CMD1 input is acti- vated. The S5 DIP switch "5" is set to OFF; this selection acti- vates the CMD1 input by a reverse-polarity condition. CMD3, CMD4, and CMD5 inputs require end-of-line resistors. The system may also be manually activated from the keypad. Press the Building Speakers button, then press the Fire Mes- sage button. Or use the microphone to make an announcement. Page 2014— DN-7004:A1 • 1/13/10 BUILDING SPEAKERS FIRE MESSAGE El El [ POWER ON SYSTEM TROUBLE MESSAGE GENERATOR TROUBLE TONE GENERATOR TROUBLE MICROPHONE TROUBLE RECORD PLAYBACK TROUBLE S H. ENCE L J Keypad Example HOST FACP NAC style FACPOLR - - (for Style Yonly) Io=:1i 4.75K ohm E0LRs, P/N 75470 4TB6TB2 185 1.234 T88 lBS 18 10 MASTER CMDI IN CMD2 IN CMD3 CMO4 CM05 CMD OUT alarm polarities shown A Fire Voice-25/50 Main Circuit Board Style Z III *1 supervisory polarity shown TB1 SPEAKER TB2 BACKUP FIRST AMPLIFIER mounted on main circuit board Figure 1: One 25 Watt Speaker Circuit NOTE: *EOLR required only for Style Y (Class B). 4.75K ohm, 1 NOTE: Typical illustration of an addressable NOTIFIER control watt, P/N 75470. panel and addressable control modules. Refer to manual for volt- age ranges, message control switch settings, and command input specifications. DN-7004:A1 • 1/13/10 - Page 3 of 4 TWO SPEAKER CIRCUITS Dual output zone, dual input circuit - tone/voice message (SEE FIGURE 2). This application example has of one NFV- 25/50 with two speaker circuits and requires the installation of a second amplifier. This configuration is suitable for small facil- ities requiring no more than 50 watts of output power and a 60- second fire evacuation message. The addressable FACP directs tone or voice messages to either of the speaker circuits via the control modules con- nected to the CMD1 and CMD2 inputs. S3 DIP switches "1", "2", and "3" are set to OFF; this selection configures CMD1/ CMD2 to direct the Fire Message to the Auditorium Speakers or Classroom Speakers. The S5 DIP switches "5" and '6" are set to ON; these contact closures activate CMD1 (switch "5") and CMD2 (switch "6") inputs. The system may also be manually activated from the keypad. Press the Auditorium Speakers and/or Classroom Speakers button(s), then press the Fire Message button. Alternately, use the microphone to make an announcement. To manually deactivate a speaker circuit, press the activated (illuminated) output zone push-button. AUDITORIUMSPEAKERS FE CLASSROOM o SPEAKERS FIRE MESSAGE F LIJ F POWERON SYSTEM TROUBLE MESSAGE GENERATOR TROUBLE GENERATOR TROUBLE MICROPHONE TROUBLE RECORD PR TROUBLE SILENCE • F-D Keypad Example HOST FACP NAC Style Z FACPEOLR ' (for Style Y only) I1 r 4.75K ohm EOLRs, PIN 75470 Tee I - - I TB2I , .1 lBS I I TEN 1 23 4 1 23 4 1 23 fl TBNfl 1510E MASTER CMD1 IN CMD2 IN CMD3 CMD4 CMO5 CMD OUT alarm polarities shown NFV-25/50 A • Main Circuit Board Style z_ II 'I I superviso,y I polarity shown I- I I I TEl SPEAKER TB2 BACKUP FIRST AMPLIFIER mounted on main circuit board Figure 2: Two Speaker Circuits, Dual Output Zone, Dual Input Circuit NOTE: "EOLR required only for Style Y (Class B). 4.75K ohm, 1 watt, P/N 75470. NOTE: Typical illustration of an addressable NOTIFIER control panel and addressable control modules. Refer to manual for volt- age ranges, message control switch settings, and command input NOTIFIER® is a registered trademark of Honeywell International Inc. specifications. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. ENGINEERING &MNUFAC11IRING All specifications are subject to change without notice. QUALITY SYSTEMS . .. Made in the U.S. A. For more information, contact Notifièrjhone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-7004:A1 • 1/13/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6911-0028:0229 Page 1 of 1 CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FireVoice-25/50 and FireVoice-25/50ZS Audio Command Center. These are 25-watt audio emergency voice evacuation control panels that provide full supervision of both normal standby and alarm conditions. An optional second audio amplifier is available as a backup to the primary amplifier or to expand speaker power to 50 watts. Refer to listee's data sheet for additional detailed product description andoperational considerations. System components: FC-XRM-70 Transformer Module FC-LPS Local Playback Speakers FC-MIM Microphone Interface Module ACC-ZPMK Zone Page Module w/Keypad ACC-ZSM Zone Splitter Module ACC-AAM-25 Audio Amplifier Module RATING: Primary: 120 V 60 Hz 1.57A Secondary: 24 V dc nominal battery voltage INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label. APPROVAL: Listed as voice communication systems for use with separately listed compatible fire alarm control units to provide emergency voice evacuation signals. Refer to listee's Installation Instructions Manual for details. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not éxcéd :30 seconds. XLF: 6911-0075:0207 . . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make •an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Cqordinator Fire Engineering Division Series E70 Speakers and Speaker Strobes L't 1 a : .J SERIES E70 STROBE SERIES E90 STROBE SERIES E70 SPEAKER SERIES E90 SPEAKER Description The Wheelock Series E Low Profile Speakers and Speaker Strobes are designed for high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from :1I8 to 2 watts. The low profile design incorporates a speaker mountingplate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. The Series E Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. Series E Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all Series E Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to complywith ADA recommendations concerning photosensitive epilepsy. Series E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the Series E Speakers and Speaker Strobes are red, white and nickel plated. MEA " APPROVED S5391 151-92-E 7125-0785:152 Features Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/N FPA/ANSI compliant Complies with OSHA 29 Part 1910.165 Wall mount models are available with Field Selectable Candela Settings of 151301751110cd or 1351185cd (Multi- Candela models), or 1575cd (Single Candela model) Ceiling mount models are available with field selectable candela settings of 15/30175195cd or 115/177cd (Multi- candela models) Strobes produce 1 flash per second over the regulated voltage range 24 VDC with wide UL Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 2 watts High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ Fast installation with IN/OUT screw terminals using #12 to #18AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on ULStandard 1971. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology 'Listed Voltage Range". Table 1: UL Max Current* E70 Strobe Current - Wall Mount E90 Strobe Current - Ceiling Mount E70/E90 Speaker 241575W 24MCW .24MCWH 24MCC 24MCCH Strobes 1575cd 15cd 30cd 75cd 110cd 135Cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 16-33 VDC j 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 Table 2: E70/E90 UL Reverberant dBA @ 10 Feet** watts 1/8 1/4 1/2 1 2 E Speaker 77 81 83 86 89 E Speaker Strobe 76 80 82 85 88 **dBA ratings are based on testing under UL Standard 1480. * UL max Current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams* SERIES E SPEAKER & STROBE OPERATE SERIES E SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY (NON-SYNC OR SYNC) WITH MULTIPLç59SM MODULES FROM ______________ _________ PRECEDING + + TO NEXT AadIbIeNACCIr [7-,1 Sy c Note: Figure APPLIANCE APPLIANCE Strobe NAC Cir. fl + I N E5j shows intercon- OR VOICE OREOLR F rtt_:—J__..JT EVACUATION DSM #2 nection to strobe PANEL FROM TO NEXT A Audible NAC Cit ________________ through sync PRECEDING + STROBE Strobe NAC Cl, Sync f1LL. E module. Speaker i= STRORE, SYNC I I - c --- '1-1- I MODULE. EOLR Audible DSM #3 portion requires 2 ,."ER SUPPLY OX P II F;;-1---7LL l separate conduc- FACP StrobeNACCo tors to FACP. STROBE SPEAKER DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES E SPEAKER STROBE APPLIANCES SERIES E SPEAKER STROBE APPLIANCES & RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH WHEELOCK POW- CLASS "A" DSM ER SUPPLIESeries 's Power Supplies S TX 0 B E 0 NAC SYNC - CIRCUIT E ST ________ EOLR OUT g+OEIT1 OUTPUTS 0- aA 1-40 * IN 1 F 1-4 MINUS 1 _QL OR ST MINUS 2 4-CLASS AUDIBLE C 2-CLASS A P * IN? OUT 2 _____________ NAC -- - --- .- - ST CIRCUIT RETURN - - Series PS Power Supplies For wiring information on the Wheelock power supplies,; please refer to Data Sheet #S9100. For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84905. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Strobe Sync wl DSM or Wheelock Power Supplies Strobe Candela -- Model Color RED Model Color White Model Color Nickel Mounting Op- tions Agency Approvals - - UL MEA CSFM FM BFP E70-24MCW-FR 9022 X - X 15/30/75/110 X - - L,OPQ,R,U,Y X X X X X E70-24MCW-FW 9023 X - X 15/30/75/110 7 X - - LOPQ,R,U,Y X X X X X E70-24MCW-FN 3099 X - X 15/30/75/110 - - X Q,U X X X X X E70-241575W-FR 7871 X - X 15 (75 on: Axis) X - - - LOPQ,R,U,Y X X - X X E70241575WFW 7876 X - X 15(75onAxis) - X - L,O,P,Q,R,U,Y X X - X X E70-241575W-FN 3100 X - X - 15 (75 on Axis) - - X L,O,P,Q,R,U,Y X X - X X E70-R 7866 X X - - X - - Q,U X X X X X E70-W 7868 X X - - - - X - Q,U X X X X X E70-N 3108 X X - - - - - X Q,U X X X X X E70-24MCC-FW 0102 X X 115/177 - - X - Q,U,V X X X X X E70-24MCWH-FR 3470 X - X 135/185 X - - L,O,PQ,R,U,Y X X X X - E70-24MCWH-FW 3474 X - X - i'35715 " - X - L,OPQ,R,U,Y X X X X - E70-24MCWH-FN 0059 X - X 135/185 - - - X Q,U X X X X - E90-24MCC-FW 3166 - X X 15/30/75/95 - X - Q,U,V X X X X - E90-24MCC-FR 3165 - X X 15/30/75/95 X - - Q,U,V X X X X - E90-24MCC-FN 3185 - X X 15/30/75/95 - - X Q,U,V X X X X - E90-W 7869 X X - - - X - Q,U,V X X X X X E90-R 7867 X X - - X - - Q,U,V X X X X X E90-N 3109 X X - - - -, -- - - X Q,U,V X X X X X E90-24MccH-Fw 3471 - X X 115/177 - X - Q,U,V X X X X - E90-24MCCH-FR 3481 - X X 115/177 X - - Q,U,V X X X X - E90-24MCCH-FN 1 0062 1 X I X 115/177 - - X Q,U,V X X X X - Also comes in NW (no writting). Models available with no writting, may be subject to minimum quantity order. Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E Speakers and the speaker strobe appliances shall be Wheelock Series E Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. A11 models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be of Ioi current design. Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings. arid: shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be white, red, or nickel plate. All speaker and speaker strobe appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S1610 E70/E90 06/11 Wheelock' tMEDCJ SAFEPATH WAV Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0152 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Frank Hertzog (732) 962-7839 Fax (732) 962-7856 Email: frank.hertzog@cooperindustries.com DESIGN: Models *ET70241575W ET70-24MCW, ET70-24MCC, ET70-24MCWH, ET70-24MCCH, *ET80241 575W, ET80-24MCW, ET80-24MCWH, *ET90..241575w ET90-24MCW, ET90-24MCC, ET90-24MCWH, ET90-24MCCH E70-24MCW, E70-24MCC, E70-24MCWH, E70-24MCCH E90-24MCW, E90-24MCC E90-24MCWH, and E90-24MCCH multi-candela speaker/strobes. Models E60-R, E60-W, E60-24MCC-FW, E60-24MCCH-FR, E60-24MCCH-FW, E60EXT-R and E60-EXT-W multi-candela speaker/strobes. May be followed by suffixes to designate lens lettering and plate color. *Lens color may be Clear, Red (R), Blue (B), Green (G), or Amber (A). EXT is an extender ring that mounts behind the speaker. Intended for indoor use only. Refer to listee's data sheet for additional detailed product description and operational coñidrat'iO'n'. RATING: Electrical: 16-33 VDC, 25/70 VRMS.: . . Flash rate: 60 flashes/mm Candela: MCW=l5cd,30cd,75cd or 110cd MCC =15cd,30cd,75cd or95cd MCWH = 135cd,185cd MCCH = 115cd,177cd *1575 = 15 cd/75cd on axis INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Models followed by W or WH are wall mounts; C or CH are ceiling mounts. All models are for indoor use. MARKING: Listee's name, model number, electrical and candela rating, and UL label. APPROVAL: Listed as strobe speakers suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM-12/24 or DSM-12/24 synchronized control modules (CSFM Listing.No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. NOTE: These units do not generate a temporal pattern signal. If the distinctive three- pulse Temporal Pattern Fire Alarm Evacuation signal (for tbtalevabuàtion) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used'with a fire alarm control unit that can generate the temporal pattern -signal., . Ile *Rev. 07-30-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v,G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 . Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Notification Sleek Modern Aesthetics Finger Slide Switches W_ - Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB *** 8 Candela Settings j Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75195/115/150/177 Universal Mounting Base 'I Ceiling and Wail Mounts to 5 Backbox Types Environmentally Friendly Ud Low Current Draw F4 Z ~ED'_ Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock® ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test ' Up to 9 models now in 1 appliance points, 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction . AA/ -, save up to i +'7O COSt or lflSLdlIdUOF..... The Wheelock® ExcederTM Series incorporates high reliability, and high efficiency optics to minimize current draw allowing for agreater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mountin base can be pre-wired to allow full testing of circuitwiring before the appliance is installed and the surface is finished. It comes' complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in.bold capital letters A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT.:,VISIT WWW.COOPERNOTIFICATION.COM bR.CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera! Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). -. Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC /1 ULMax Current* at Anechoic 99 dBA 24Vbc VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15/75 Range VDC T0.125 HS 8.0-33.0 0.082 0.095 0.102 ' 0.148 0,176 0.197 0.242 0.28 0.159 HSC 8.0-33.0 0.082 0,102 0.141 0.148 0.176 . 0.197 . 0.242 0.282 UL Max Current* at Anechoic 95 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 . 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 , 0.186 , 0.230 0.272 0.122 UL Max Current* at Anechoic 90 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0,084 . 0.136 0.157 0,184 , 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 HornRatings per UL Anechoic Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33,0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0,017 * UL max current rating is the maximum RMS Current within the listed voltage range (16-33 VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24VDC units). For audibles the max current is usually at the maximum listedvoltage (33 VDC for 24 VDC units). For unfiltered rating, see installation instructions. Specification & Ordering Information, Sync w/ Strobe OSM or Mounting Model 12124 VDC Candela Wheelock Power Options Supplies HSR - 15/1575/30/75/95/110/135/185 X X X X X UMB** X UMB** X UMB X UMB** HSW 15/1575/30/75/95/110/135/185 HSRC 15/30/60/75/95/115/150/177 HSWC 15/30/60/75/95/115/150/177 ')1 STIR 15/1575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** STVVC 15/30/60/75/95/115/150/177 X X UMB** 4HNR X UMB** X HNW HNR HN 2 HNWC 2 UMB** * 12 VDC models feature 15 & 15/75 settings **UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specificatiohs and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Cohtrol Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock°'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 Wheelock (MEDCJ SAFEPATH WAV Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Frank Hertzog (732) 962-7839 Fax (732) 962-7856 Email: frank.hertzog@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110,135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the, applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make, an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories H Description: ' Designed for life safety, performance and reliability, Cooper All models may be synchronized using the Wheelock DSM Sync Notification's Wheelock cost effective weatherpoàf,notification Modules, Wheelock Power Supplies or other manufacturers appliances include: panels incorporating the Wheelock Patented Sync Protocol. The Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-12WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-35°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper Notification provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA* and WFPA° kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. MEA °' APPROVED E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) horn output of horn strobes can be independently controlled on 2 wire circuits using the Wheelock patented sync protocol MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM), Chicago (BFP) and ULC . See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal The series RSSWP, ASWP, AH-24WP, MTWP-2475W, and MT-12/24 have UL/ uLc approval down to -40°F. The ET-1 010 and ET70WP have UL approval down to -40°F. The AH-1 2WP has UL approval down to -31'F NOTE: All CAUTIONS and WARNINGS are identified by the symbol A..AII warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL.Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount r,iiwp Ceiling Mount H( 0iR: RSSWP MTWP S. I i ASWP ET70WP Wall or Ceiling Mount Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 Audible Order Code RSSWP-2475W-FW White 3034 RSSWP-2475C.FW White 4446 AH-24WP-R Red 7416 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 AH-12WP-R Red 7415 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWWhite 5187 Multi-tone Strobe MTWP-2475W-FR Red MTWP-2475W-FW White MT\NP-24MCWH-FR Red MTWP-24MCWH-FW White Speaker Strobe ET70WP-2475W-FR Red ET70WP-2475W-FW White ET70WP24 185W-FR Red ET70WP-241 85W-FW White ET70WP-241 35W-FR Red ET70WP-241 35W-FW White Audible Strobe ASWP-2475C-FR Red 4251 ASWP-2475C-FW White 4502 ASWP-24MCCH-FR Red 5149 ASWP-24MCCH-FW White 5157 8420 Multi-tone Strobe 3112 MTWP-2475C-FR Red 4457 5132 MTWP-2475C-FW White I t4478 5134 MTWP-24MCCH-FR Red 5102 MTWP-24MCCH-FW White 5122 9077 Speaker Strobe 3179 ET70WP-2475C-FR Red 4452 4885 ET70WP-2475C-FW White 4454 4891 ET70WP-24177C-FR Red 4845 4872 ET70WP-24177C-FW White 4859 4875 ET70WP-24115C-FR Red 4550 ET70WP-24115C-FW White 4732 Horn MT-1 2/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max. Current AH 24VDC 12VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 UL Reverberant dBA © 10 Feet Wafts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 90 93 95 Audible Strobe ASWP-2475W-FR Red 9012 ASWP-24MCWH-FR Red 5137 ASWP-24MCWH-FW White 5140 Candela Ratings Series UL 1971 UL 1638 @ 77°F UL 1638 @ -40°F RSS, ET70WP and MTWP UL Max Current (Strobe Only) ASWP High Med Low 2475 3Q** 180 115 0.138 0.168 0.155 0.150 135 135 56 0.300 0.355 0.340 0.335 MCWH 185 185 77 0.420 0.480 0.465 0.460 115 115 47 0.300 0.355 0.340 0.335 MCCH 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VOC dBA HI STO HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X - RSSWP-24MCWH X - X - - RSSWP-24MCCH X - X - - Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X - X - - ASWP-MCCH X - X - - Multitone Strobe MTWP-2475 X X X X - MTWP-MCWH X - X - - MTWP-MCCH X - X - - Horns!Audibles AH-24WP X X X X X AH-12WP X X X X X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X - X X - ET70WP-185 X - X X - ET70WP-177 X - X X - ET70WP-115 X - X X - ET70WP-135 X Mounting Accessories DO WFP WFPA Gasket Kit Order Code WP-KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes lOBR* Red 5046 IOBW* White 5047 WPSBBR* Red 9751 WPSBBW* White 3033 WPBBR* Red 9014 WPBBW* White 4692 WBB-R Red 2959 WBB-W White 2960 lOB WPSBB WPBB WBB Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA AHWP Horns WBB - WFP ET-1010 Speakers WBB - WFP MTWP Multitone Horn Strobes lOB lOB + WP-KIT WFP Multitone Horn lOB lOB + WP-KIT WFP *1013, WPSBB and WPBB models include weep holes and plug in the event that moisture may have entered the appliance Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. FROM + + TO NEXT PRECEDING APPLIANCE APPLIANCE - RED - OR EOLR OR FACP BLACK STROBE AUDIBLE I SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12124 I 'APPLIANCES I I FROM TO NEXT I II PRECEDING + tl'—i r APPLIANCE APPLIANCE OR I OR EOLR FACP SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWP o Strobe Sync Circuit .-,. I I I I 1) Module NAC #1 I I o PS r Ø Au ibie Power Circuit FACP Supply JJ1IItIIIIIIF} NAC#2 Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE 0 NAC SYNC - 0 CIRCUIT OUT 0±OUT1 10 0 + IN 1 ST 0M1NU51 FACP 0 1 AUDIBLE 1 ST: MINUS 2 + IN 2 RSS STROBE NAC O+ OUT 2 CIRCUIT RETURN Note: Models are available in Red or White. Contact Customer Service for Order. Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications :and offerings are subject to change without notice in accordance with Cooper Wheelock Inc. dba Cooper Notification standard terms and conditions. S9004 WP 06/11 Notification Wheelock* (MEDCJ SAFEPATH ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard .1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock nounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output ora temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. .Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to coded or continuous NAC. 'Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. I-Nw-I' IThI WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0785:0154 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Cooper Wheelock Inc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Frank Hertzog (732) 962-7839 Fax (732) 962-7856 Email: frank.hertzog@cooperindustries.com DESIGN: Models RSSWP-2475W and RSSWP-2475C synchronous or non-synchronous strobe light. Model may be followed by two alpha or numeric characters indicating lettering and color, followed by W for wall mount or C for ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. Models RSSWP-24MCWH (wall mount) & RSSWP-24MCCH (ceiling mount) audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. RATING: Electrical: 16-33 VDCNFWR Flash rate: 60 flashes/mm. Candela: RSSWP-2475W 30cd (115cd at-40 C) RSSWP-2475C 30cd (115cd at-40 C) RSSWP-24MCWH Selectable 135/1 85cd (65/90cd at-40 C) RSSWP-24MCCH Selectable 115/177cd (50/75cd at-40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model can be used outdoors when used with WPSBB back box only. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a strobe light for use with separately listed electrically compatible fire alarm control units. For indoor or outdoor use. Intended for wall mount or ceiling mount. Lens color may be white, red, blue, green or amber. For synchronized strobes, Models SM-12/24, SMX-12/24 Sync Modules, DSM-12/24 or DSMX-12/24 Duel Sync Modules (CSFM Listing No. 7300-0785:1323) or power supply PS-12/24-8 (CSFM Listing No. 7315-0785:149) must be used. NOTE: *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listéesdata sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division S