HomeMy WebLinkAbout5815 EL CAMINO REAL; ; FPC2018-0323; PermitPERMIT REPORT Cdisbad (-City of Print Date: 02/17/2022 Permit No: FPC2018-0323 Job Address: 5815 ELCAMINO REAL, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track #: Applied: 09/27/2018 Valuation: $0.00 Lot #: Issued: 10/29/2018 Occupancy Group: Project #: Finaled Close Out: 02/11/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: DCDA BACKFLOW REPLACEMENT FOR 5815 EL CAM INO REAL Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MATT JORGENSEN 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $756.00 Total Payments To Date: $756.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov San Diego Branch Office .10II00. cosco 4990 Greencraig Lane . 1 1.1..,. San Diego, CA 92123 S. •• •I• Fire Protection (858) 444-2000 fax: 444-2056 CA Lie.: C-16 #577621 www. coscofi re. corn MATERIAL SUBMITTAL & HYDRAULIC CALCULATIONS Date: 9-26-18 5815 El Camino Real Backflow Replacement 5815 El Camino Real Carlsbad, CA 92008 JOB # 1O.CD_5870 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. FPC20I8-0323 5815 EL CAMINO REAL DCDA BACKFLOW REPLACEMENT FOR 5815 EL CAMINO REAL Submitted by: Matt Jorgensen 9/27/2018 FPC20I 8-0323 Los Angeles • San Francisco • Orange • Fresno * San Diego • Seattle ZURN M odel 3500 WILKINS Double Check Detector Assembly Application Designed for installation on water lines in fire protection systems WILKINS to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Sizes 2 1/2 - 10 Horiz. &Vert.) (12 Horizontal Only) ASSE® Listed 1048 (Sizes 2 1/2 thru 12) CSA® Certified B64.5 (Sizes 2 1/2 thru 8°, & 12) AWWA Compliant C510 (Sizes 2 1/2 thru 12), and C550 UL® Classified (Sizes 2 1/2 thru 12) C-UL® Classified (Sizes 2 1/2 thru 12) FM® Approved (Sizes 2 1/2 thru 10) NYC MEA 147-99-M Vol 4 (2-1/2 - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2 thru 12) Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backflow Assembly 3/4 Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless Steel, 300 Series Features Sizes: 2 1/2, 3, 4, 6, 8, 10, 12 Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) NSF/ANSI SI Options (Suffixes can be combined) - with OS & Y gate valves (standard) L - less shut-off valves (flanged body connections) 9 LM - less water meter - with remote reading meter - with gallon meter (standard) 9 CFM - with cu ft meter 9 CMM - with cu meter meter 9 G - with groove end gate valves 9 FG - with flanged inlet connection and grooved outlet connection 9 P1 - with Post Indicator Gate Valve 9 GF - with flanged inlet connection and grooved outlet connection 9 BG - with grooved end butterfly valves with integral monitor switches (2 1/2 - 10°) 9 -509 - with AWWA C509 gate valves Accessories 9 Repair kit (rubber only) 9 Thermal expansion tank (Model XT) 9 OS & Y Gate valve tamper switch (OSY-40) Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. 00 i,1iIi1 iIIIIi1ii DIMENSION _(app rwimaIe) WEIGHT MODEL A B LESS E E E LESS OS&Y OS&Y BUTTERFLY 350DA A WITH GATE c D OS&Y OS&Y WITH F SHUTOFF GATE GATEVALVES SIZE BUTTERFLY VALVES OPEN CLOSED BUTTERFLY VALVES VALVES VALVES GROOVED VALVES VALVES FLANGED GROOVED in. mm in. mm in. I mm in. mm in. mm in. mm in. I mm in, mm in. I mm in. mm lbs Ja lbs. I kg lbs. kg lbs. I kg 21/2 65 1 31 787 28 711 157/8 403 33/4 95 9 229 173/41451 153/8 391 81/4 210 31/2 89 68 31 178 81 160 73 140 64 3 32 813281/2724Th7/840333/4959229201/4 5U 17 216 68 31 120 54 4 100 375/8 956 328/9 835 191/2 495 41/2 114 9 229 221/21 572 181/4 464 9 229 6 152 106 48 296 134 282 128 190 86 6 r20 443/4 37 37518 956 231/2 597 6 Th2 1012 267 301/2 775 24V4 6 101/4 260 7 178 0 82 480 8 454 28 206 298 5 8 603/41543537181369373/4959 10 254 12 305 37 940 281/2 724 12 305 81/2 216 374 170 850 386 802 364 548 249 10 250 63314 1619 577/8 1470 373/4 959 10 254 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Rabies, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 11_2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. H Date: 1/17 Document No. BF-350DA Patent No. 5, 913, 331 Product No. Model 350DA Page 1 of 2 S PROTECTIVE VERTICAL INSTALLATION Flow Characteristics ' Rated Flow (established by approval agencies) MODEL 350DA 2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (us) 12.6 25.2 37.9 50.5 -- -- - - .•___________• - - - I LIII 'i I fiJI 800 all. 157.7 — — — ----- — — — — — — — 69 Ow 34 u 103 CI) 0 -J CI) 0 2000 2500 220.8 252.4 283.9 -- -- -- -- - -- -- -- -- --Td :1 MOM mom — - -- ri;- — -- -- -- ____ -- — -- -- -- -- -- I.- -- -- -- -- -- -- 0 0 500 1000 1500 2000 2500 3000 3500 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 (305mm) and a maximum of 30 (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2' 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 1 5288 OUTDOOR INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers S shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 350DA. Zurn Industries, LLC I Wilkins 1747 commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 - - - Fire Protection by Computer Design COSCO FIRE PROTECTION 4990 GREENCRAIG LANE Your Street Address 2 SAN DIEGO, CA 92123 (858) 444-2000 Job Name : 5815 EL CAMINO REAL Building Location System Contract Data File : 10.CD_5870 5815 El Camino Real.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 S Water Sup :60TECTION Curve C COSCO FIR 5815 EL CAMINO REAL Page • Date 9-21-18 City Water Supply: Demand: Cl - Static Pressure : 88 Dl - Elevation : 1.299 C2 - Residual Pressure: 79 D2 - System Flow : 206.2 C2 - Residual Flow : 1560 D2 - System Pressure : 86.011 Hose ( Demand) : 100 D3 - System Demand : 306.2 Safety Margin : 1.546 150 140 130 p120 R° E10° S 90 s 80 U70 - R6° E 40 ° 30 20 10 20 400 600800 1000 1200 1400 1600 1800 FLOW ( N ' 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary COSCO FIRE PROTECTION Page 2 5815 EL CAMINO REAL Date 9-21-18 Fitting Legend Abbrev. Name ¼ ¼ 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. 0 Computer Programs by Hyec Inc. Revision: 50.52.1 9 Pressure / Flow Summary - STANDARD COSCO FIRE PROTECTION Page 3 5815 EL CAMINO REAL Date 9-21-18 Le Elevation K-Fact Pt Pn Flow Density Area Press Actual Actual Req. BOR 6.0 77.6 na 206.2 UG1 -3.0 81.72 na UG2 -3.0 82.52 na BF1 3.0 80.15 na BF2 3.0 80.17 na BF3 3.0 85.2 na UG3 -3.0 88.13 na TEST 3.0 86.01 na 100.0 The maximum velocity is 5.01 and it occurs in the pipe between nodes BOR and UG1 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams - 2007 COSCO FIRE PROTECTION Page 4 5815 EL CAMINO REAL Date 9-21-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 206.20 4.1 E 14.534 9.000 77.600 Qa = 206.20 to 140.0 0.0 14.534 3.898 UG1 206.2 0.0096 0.0 23.534 0.226 Vel = 5.01 UG1 0.0 4.23 2E 38.446 71.500 81.724 to 150.0 0.0 38.446 0.0 UG2 206.2 0.0072 0.0 109.946 0.797 Vel = 4.71 UG2 0.0 4.1 E 14.534 6.000 82.521 to 140.0 G 2.907 17.441 -2.599 BF1 206.2 0.0096 0.0 23.441 0.225 Vel = 5.01 BF1 0.0 4.26 0.0 1.875 80.147 to 120.0 0.0 0.0 0.0 BF2 206.2 0.0107 0.0 1.875 0.020 Vel = 4.64 BF2 0.0 4.1 0.0 3.145 80.167 to 140.0 0.0 0.0 5.000 * Fixed Loss = 5 BF3 206.2 0.0095 0.0 3.145 0.030 Vel = 5.01 BF3 0.0 4.1 2E 29.067 6.000 85.197 to 140.0 0.0 29.067 2.599 UG3 206.2 0.0096 0.0 35.067 0.336 Vel = 5.01 UG3 0.0 4.23 G 3.845 23.500 88.132 to 150.0 T 38.446 42.290 -2.599 TEST 206.2 0.0073 0.0 65.790 0.478 Vel = 4.71 100.00 Qa = 100.00 306.20 86.011 K Factor = 33.02 to Computer Programs by Hydratec Inc. Revision: 50.52.1