Loading...
HomeMy WebLinkAbout5617 PASEO DEL NORTE; ; FA130044; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA130044 5617 PASEO DEL Job Address: NORTE Permit Type: FALARM Parcel No: 2110213400 Lot #: 0 Reference No.: PC #: Status: PENDING Applied 7/3/2013 Approved: Issued: Inspector: Project Title: SOCCER LOCO RELOCATE ONE HORN/STROBES—CONNECT EXISTING FA SYSTEM AND PROGRAM ALL COMPONENTS Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: CPT/SC TITLE HOLDING CORP C/O STRATEGIC PROPERTY ADVISERS I 3250 VISTA DIEGO RD JAMUL CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 286 0 286 0 THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT (frLi FIR Do E ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. PROPERTY INFORMATION Name of property: PASEO DEL NORTE - SOCCER LOCO STE. 131- ADDING ONE STROBE Address: 1 5617 PASEO DEL NORTE STE 131 , CARLSBAD, CA 92010 Description of property: RETAIL Occupancy type: B Name of property representative: Address: Phone: Fax: E-mail: Authority having jurisdiction over this property: CARLSBAD F.D. Phone: Fax: E-mail: INSTALLATION, SERVICE, AND TESTING CONTRACTOR INFORMATION Installation contractor for this equipment: JJJ ENTERPRISES Address: 533 S. VINEWOOD, ESCONDIDO, CA 92029 License or certification number: 582169 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Service organization for this equipment: Address: License or certification number: Phone: Fax: E-mail: A contract for test and inspection in accordance with NFPA standards is in effect as of: Contracted testing company: Address: Phone: Fax: E-mail: Contract expires: Contract number: Frequency of routine inspections: DESCRIPTION OF SYSTEM OR SERVICE Fire alarm system (nonvoice) LI Fire alarm with in-building fire emergency voice alarm communication system (EVACS) LI Mass notification system (MNS) LI Combination system, with the following components: LI Fire alarm LI EVACS LI MI'JS LI Two-way, in-building, emergency communication system LI Other (specify): NFPA 72, Fig. 10.18.2.1.1 (p.1 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 3. DESCRIPTION OF SYSTEM OR SERVICE (continued) NFPA 72 edition: 2010 Additional description of system(s): 3.1 Control Unit Manufacturer: NOTIFIER 3.2 Mass Notification System 3.2.1 System Type: El In-building MNS—combination El In-building MNS—stand-alone El Other (specify): 3.2.2 System Features: Model number: NFW2 100 This system does not incorporate an MNS 0 Wide-area MNS El Distributed recipient MNS 0 Combination fire alarm/MNS El MNS autonomous control unit 0 Wide-area MNS to regional national alerting interface El Local operating console (LOC) 0 Direct recipient MNS (DRMNS) 0 Wide-area MNS to DRMNS interface El Wide-area MNS to high-power speaker array (HPSA) interface El In-building MNS to wide-area MNS interface Li Other (specify): 3.3 System Documentation An owner's manual, a copy of the manufacturer's instructions, a written sequence of operation, and a copy of the numbered record drawings are stored on site. Location: FACP 3.4 System Software This system does not have alterable site-specific software. Operating system (executive) software revision level: Site-specific software revision date: Revision completed by: El A copy of the site-specific software is stored on site. Location: 3.5 Off-Premises Signal Transmission El This system does not have off-premises transmission. Name of organization receiving alarm signals with phone numbers: Alarm: JJJENTERPRISES Phone: Supervisory: SAME Phone: Trouble: SAME Phone: Entity to which alarms are retransmitted: Phone: Method of retransmission: If Chapter 26, specify the means of transmission from the protected premises to the supervising station: If Chapter 27, specify the type of auxiliary alarm system: El Local energy El Shunt Z Wired 0 Wireless NFPA 72, Fig. 10.18.2.1.1 (p.2 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resate. It may not be copied for commercial sate or distribution. 4. CIRCUITS AND PATHWAYS 4.1 Signaling Line Pathways 4.1.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: 1 Quantity: (See NFPA 72, Sections 12.3 and 12.4) 4.1.2 Pathways Utilizing Two or More Media Quantity: Description: 4.1.3 Device Power Pathways No separate power pathways from the signaling line pathway ED Power pathways are separate but of the same pathway classification as the signaling line pathway J Power pathways are separate and different classification from the signaling line pathway 4.1.4 Isolation Modules Quantity: 4.2 Alarm Initiating Device Pathways 4.2.1 Pathways Class Designations and Survivability Pathways class: Survivability level: Quantity: (See NFPA 72, Sections 12,3 and 12.4) 4.2.2 Pathways Utilizing Two or More Media Quantity: Description: 4.2.3 Device Power Pathways No separate power pathways from the initiating device pathway E Power pathways are separate but of the same pathway classification as the initiating device pathway Fj Power pathways are separate and different classification from the initiating device pathway 4.3 Non-Voice Audible System Pathways 4.3.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: , 1 Quantity: 16 (See NFPA 72, Sections 12.3 and 12.4) 4.3.2 Pathways Utilizing Two or More Media Quantity: Description: 4.3.3 Appliance Power Pathways No separate power pathways from the notification appliance pathway D Power pathways are separate but of the same pathway classification as the notification appliance pathway El Power pathways are separate and different classification from the notification appliance pathway NFPA 72, Fig. 10.18.2.1.1 (p. 3 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 5. ALARM INITIATING DEVICES 5.1 Manual Initiating Devices 5.1.1 Manual Fire Alarm Boxes Type and number of devices: Addressable: Other (specify): 5.1.2 Other Alarm Boxes Description: Type and number of devices: Addressable: Other (specify): 5.2 Automatic Initiating Devices This system does not have manual fire alarm boxes. Conventional: Coded: Transmitter: This system does not have other alarm boxes. Conventional: Coded: Transmitter: 5.2.1 Smoke Detectors El This system does not have smoke detectors. Type and number of devices: Addressable: 8 Conventional: Other (specify): Type of coverage: El Complete area El Partial area El Nonrequired partial area Other (specify): Type of smoke detector sensing technology: El Ionization Z Photoelectric El Multicriteria 0 Aspirating El Beam Other (specify): 5.2.2 Duct Smoke Detectors 0 This system does not have alarm-causing duct smoke detectors. Type and number of devices: Addressable: 47 Conventional: Other (specify): Type of coverage: Type of smoke detector sensing technology: El Ionization Z Photoelectric El Aspirating El Beam 5.2.3 Radiant Energy (Flame) Detectors Z This system does not have radiant energy detectors. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: 5.2.4 Gas Detectors Z This system does not have gas detectors. Type of detector(s): Number of devices: Addressable: Conventional: Type of coverage: 5.2.5 Heat Detectors El This system does not have heat detectors. Type and number of devices: Addressable: 7 Conventional: Type of coverage: El Complete area El Partial area El Nonrequired partial area El Linear El Spot Type of heat detector sensing technology: El Fixed temperature 0 Rate-of-rise El Rate compensated NFPA 72, Fig. 10.18.2.1.1 (p. 4 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 5. ALARM INITIATING DEVICES (continued) 5.2.6 Addressable Monitoring Modules Number of devices: 3 5.2.7 Waterfiow Alarm Devices Type and number of devices: Addressable: 1 5.2.8 Alarm Verification Number of devices subject to alarm verification: 5.2.9 Presignal Number of devices subject to presignal: Describe presignal functions: 5.2.10 Positive Alarm Sequence (PAS) Describe PAS: 5.2.11 Other Initiating Devices Describe: LI This system does not have monitoring modules. LI This system does not have waterfiow alarm devices. Conventional: Coded: Transmitter: This system does not incorporate alarm verification. Alarm verification set for seconds This system does not incorporate pre-signal. This system does not incorporate PAS. This system does not have other initiating devices. 6. SUPERVISORY SIGNAL-INITIATING DEVICES 6.1 Sprinkler System Supervisory Devices LI This system does not have sprinkler supervisory devices. Type and number of devices: Addressable: 2 Conventional: Coded: Transmitter: Other (specify): 6.2 Fire Pump Description and Supervisory Devices Z This system does not have a fire pump. Type fire pump: LI Electric pump LI Engine Type and number of devices: Addressable: Conventional: Coded: Transmitter: Other (specify): 6.2.1 Fire Pump Functions Supervised LI Power LI Running LI Phase reversal LI Selector switch not in auto LI Engine or control panel trouble LI Low fuel Other (specify): 6.3 Duct Smoke Detectors (DSDs) LI This system does not have DSDs causing supervisory signals Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: Type of smoke detector sensing technology: LI Ionization LI Photoelectric LI Aspirating LI Beam 6.4 Other Supervisory Devices LI This system does not have other supervisory devices. Describe: NFPA 72, Fig. 10.18.2.1.1 (p.5 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. MONITORED SYSTEMS 7.1 Engine-Driven Generator 7.1.1 Generator Functions Supervised O Engine or control panel trouble LI Generator running LI Other (specify): 7.2 Special Hazard Suppression Systems Description of special hazard system(s): 7.3 Other Monitoring Systems Description of special hazard system(s): ANNUNCIATORS 8.1 Location and Description of Annunciators Location I: ELEV LOBBY Location 2: Location 3: This system does not have a generator. LI Selector switch not in auto LI Low fuel This system does not monitor special hazard systems. This system does not monitor other systems. LI This system does not have annunciators. ALARM NOTIFICATION APPLIANCES 9.1 In-Building Fire Emergency Voice Alarm Communication System 0 This system does not have an EVACS. Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker circuits: Location of amplification and sound-processing equipment: Location of paging microphone stations: Location I: Location 2: Location 3: 9.2 Nonvoice Notification Appliances LI This system does not have nonvoice notification appliances. Horns: 33 With visible: 33 Bells: With visible: Chimes: With visible: Visible only: 27 Other (describe): 9.3 Notification Appliance Power Extender Panels LI This system does not have power extender panels. Quantity: 3 Locations: STE 200, SERENITY MASSAGE, FACP ROOM, -214 NFF'A 72, Fig. 10.18.2.1.1 (p.6 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. MASS NOTIFICATION CONTROLS, APPLIANCES, AND CIRCUITS Z This system does not have an MNS. 10.1 MNS Local Operating Consoles Location 1: Location 2: Location 3: 10.2 High-Power Speaker Arrays Number of HPSA speaker initiation zones: Location I: Location 2: Location 3: 10.3 Mass Notification Devices Combination fire alarm/MNS visible appliances: MNS-only visible appliances: Textual signs: Other (describe): Supervision class: 10.3.1 Special Hazard Notification This system does not have special suppression predischarge notification. LI MNS systems DO NOT override notification appliances required to provide special suppression predischarge notification. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS 11.1 Telephone System This system does not have a two-way telephone system. Number of telephone jacks installed: Number of warden stations installed: Number of telephone handsets stored on site: Type of telephone system installed: El Electrically powered LI Sound powered 11.2 Two-Way Radio Communications Enhancement System Li This system does not have a two-way radio communications enhancement system. Percentage of area covered by two-way radio service: Critical areas: % General building areas % Amplification component locations: Inbound signal strength: dBm Outbound signal strength: dBm Donor antenna isolation is: dB above the signal booster gain Radio frequencies covered: Radio system monitor panel location: NEPA 72, Fig. 10.18.2.1.1 (p. 7 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS (continued) 11.3 Area of Refuge (Area of Rescue Assistance) Emergency Communications Systems Li This system does not have an area of refuge (area of rescue assistance) emergency communications system. Number of stations: Location of central control point: Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: 11.4 Elevator Emergency Communications Systems O This system does not have an elevator emergency communications system. Number of elevators with stations: Location of central control point: Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: 11.5 Other Two-Way Communication Systems Describe: CONTROL FUNCTIONS This system activates the following control fuctions Li Hold-open door releasing devices Li Smoke management Li HVAC shutdown LI F/S dampers LI Door unlocking Li Elevator recall LI Fuel source shutdown Li Extinguishing agent release LI Elevator shunt trip LI Mass notification system override of fire alarm notification appliances Other (specify): 12.1 Addressable Control Modules Li This system does not have control modules. Number of devices: Other (specify): SYSTEM POWER 13.1 Control Unit 13.1.1 Primary Power Input voltage of control panel: 120VAC Control panel amps: 3 Overcurrent protection: Type: INTERNAL FUSE Amps: Location (of primary supply panel board): MAIN ELECTRIC ROOM Disconnecting means location: BREAKER 13.1.2 Engine-Driven Generator This system does not have a generator. Location of generator: Location of fuel storage: Type of fuel: (VFPA 72, Fig. 10182.1.1 (p8o112) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 13. SYSTEM POWER (continued) 13.1.3 Uninterruptible Power System Z This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 13.1.4 Batteries Location: FACP Type: ACM Calculated capacity of batteries to drive the system: In standby mode (hours): 24 Batteries are marked with date of manufacture Nominal voltage: 12 Amp/hour rating: 12 In alarm mode (minutes): 5 0 Battery calculations are attached 13.2 In-Building Fire Emergency Voice Alarm Communication System or Mass Notification System Z This system does not have an EVACS or MINS system. 13.2.1 Primary Power Input voltage of EVACS or M'NS panel: Overcurrent protection: Type: Location (of primary supply panel board): Disconnecting means location: EVACS or M'NS panel amps: Amps: 13.2.2 Engine-Driven Generator Z This system does not have a generator. Location of generator: Location of fuel storage: Type of fuel: 13.2.3 Uninterruptible Power System Z This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 13.2.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode (hours): In alarm mode (minutes): El Batteries are marked with date of manufacture El Battery calculations are attached NFPA 72, Fig. 10.18.2,1.1 (p.9 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. SYSTEM POWER (continued) 13.3 Notification Appliance Power Extender Panels D This system does not have power extender panels. 13.3.1 Primary Power Input voltage of power extender panel(s): 120VAC Power extender panel amps: Overcurrent protection: Type: BREAKER Amps: 20 Location (of primary supply panel board): VARIOUS SUBPANELS Disconnecting means location: BREAKER 13.3.2 Engine-Driven Generator Location of generator: Location of fuel storage: Type of fuel: This system does not have a generator. 13.3.3 Uninterruptible Power System Z This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 13.3.4 Batteries Location: IN FOPS Type: AGM Nominal voltage: 12 Amp/hour rating: 7 Calculated capacity of batteries to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 Batteries are marked with date of manufacture E Battery calculations are attached RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. This is a: Z New system Z Modification to an existing system Permit number: The system has been installed in accordance with the following requirements: (Note any or all that apply.) NFPA 72, Edition: 2010 NFPA 70, National Electrical Code, Article 760, Edition: 2010 Manufacturer's published instructions Other (specify): System deviations from referenced NFPA standards: Sig . Printed name: JIM MCKINLEY Date: 9/19/13 Organizati : JJJ Enterprises Title: PROJECT MGR Phone: 760-747-3050 NFPA 72, Fig. 10.18.2.1.1 (p. 10 of 12) Copyright © 2009 National Fire Protection Association, This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. RECORD OF SYSTEM OPERATIONAL ACCEPTANCE TEST Z New system All operational features and functions of this system were tested by, or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements for the following: L Modifications to an existing system All newly modified operational features and functions of the system were tested by, or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of the following: NFPA 72, Edition: 2010 NFPA 70, National Electrical Code, Article 760, Edition: 2008 Manufacturer's published instructions Other (specify): E lncl.Lvdta• evice testing doc ntation [Inspection and Testing Form (Figure 14.6.2.4) is attached] : Printed name: JIM MCKINLEY Date: 9/19/13 Organizati: JJJ Enterprises Title: PROJECT MGR Phone: 760-747-3050 CERTIFICATIONS AND APPROVALS 16.1 System Installation Contractor: This system, as specified herein, has b n installed and tested according to all NFPA standards cited herein. Si ~:, '4 Printed name: JIM MCKINLEY Date: 9/19/13 organizatio2/ JJJ Enterprises Title: PROJECT MGR Phone: 760-747-3050 16.2 System Service Contractor: The undersigned has a service contrac or this system in ettect as ot the date shown below. Sign Printed name: JIM MCKINLEY Date: 9/19/13 Organizat' n: JJJ Enterprises Title: PROJECT MGR Phone: 760-747-3050 16.3 Supervising Station: This system, as specified herein, will be monitored according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: NFPA 72, Fig. 10,18.2.1.1 (p.11 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 16. CERTIFICATIONS AND APPROVALS (continued) 16.4 Property or Owner Representative: I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 16.5 Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, with its approved sequence of operations, and with all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: NFPA 72, Fig. 10.18.2.1.1 (p. 12 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution.