HomeMy WebLinkAbout1820 MARRON RD; ; FA160073; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160073 Job Address: 1820 MARRON RD Status: ISSUED Permit Type: FALARM Applied 10/13/2016 Parcel No: 1563011600 Approved: 10/13/2016 Lot #: 0 Reference No.: Issued: 10/13/2016 PC #: Inspector: Project Title: HOMEROOM HOURLY DAY CARE T.I.: FIRE ALARM PLANS Applicant: RED HAWK FIRE & SECURITY 920 SOUTH ANDREASEN DR SUITE 102 ESCONDIDO, CA 760-233-9787 Owner: P K I NORTH COUNTY PLAZA L P C/O KIMCO REALTY CORP 3333 NEW HYDE PARK RD #100 NEW HYDE PARK NY Add'I Fees ($) Total ($) Balance ___ THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT r_'*~A A " two-43 n SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 10/17/16 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: Homeroom Hourly Day Care Address: 1820 Marron Road, Carlsbad, CA 92008 Description of property: Day Name of property representative Address: Same Phone: Fax: E-mail: cassie@homeroomcare.com INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Red Hawk Fire & Security Address: 920S. Andreasen Drive, Suite 102, Escondido, CA 92029 Phone: 760-233-9787 Fax: 760-233-9788 E-mail: john.stasukevich@redhawkus.com Care Cassandra Hall Service organization: Same Address: Phone: Testing organization: Same Address: Phone: Fax: E-mail: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: Red Hawk via Verizon Wireless Address: 7700 Gulf Frwy, Houston, TX 77017 Phone: Fax: 877-218-0470 E-mail: gputcfsuscfusade@redhawkus.com> Account number: 297-5277 Phone line 1: N/A Phone line 2: N/A Means of transmission: Cellular Entity to which alarms are retransmitted: Red Hawk Fire & Security Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: Office DESCRIPTION OF SYSTEM OR SERVICE This is a: New system 0 Modification to existing system Permit number: NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: EST Model number: FS502GD 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p.1 of 3) SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120VAC Overcurrent protection: Type: Circuit Breaker Branch circuit disconnecting means location: House Panel 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 Control panel amps: 3 Amps: 20 Number: 12 In alarm mode (minutes): 5 5.2 Control Unit E] This system does not have power extender panels E] Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line Device Power B Initiating Device B Notification Appliance B Other (specify): REMOTE ANNUNCIATORS Location INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 Conventional Alarm Switch Smoke Detectors 3 Conventional Alarm Photoelectric Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches Tamper Switches Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2 of 3) SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 4 Strobe Combination Audible and Visible 1 Horn Strobe SYSTEM CONTROL FUNCTIONS Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dan Door Unlocking Elevator Recall Elevator Shunt INTERCONNECTED SYSTEMS This system does not have interconnected systems. El Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as s ecified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: John Stasukevich Date: Organiz tion: Red Hawk Fire & Security Title: Project Manager Phone: 10/17/16 7r 12.2 System Operational Test This system as specified herein has te ted according to all NFPA standards cited herein. Signed: Printed name: Organiz ion: Red Hawk Fire & Security Title: Project Manager 12.3 Acceptance Test Date and time of acceptance test: 10/17/16 3:00pm PST Date: 10/17/16 Phone: 760-535-0045 Installing contractor representative: John Stasukevich Testing contractor representative: John Stasukevich Property representative: Cassandra Hall AHJ representative: Ct2 Copyright © 2012 National Fire Protection Association This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p.3 of 3)