Loading...
HomeMy WebLinkAbout5840 EL CAMINO REAL; 100; FPC2017-0002; PermitPERMIT REPORT (City of Carlsbad Print Date: 03/02/2022 Permit No: FPC2017-0002 Job Address: 5840 EL CAMINO REAL, # 100, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090503200 Track #: Applied: 01/05/2017 Valuation: $92,658.72 Lot #: Issued: 01/13/2017 Occupancy Group: Project #: Finaled Close Out: 02/22/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check tt: Inspector: Plan Check#: Final Inspection: Project Title: Description: BREW IGNITER -8 HEAD SPRINKLER TI -SUITE 100-101 FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION INC 9925 PROSPECT AVE, # STE B SANTEE, CA 92071 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 - Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov - 0002.. tqccs Fire Protection Products Worldwide www.tyco-fire.com Contacts Series DS-1 - 56 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprin- kler drops from unheated portions of buildings) sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g., sprin- kler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or hor- izontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) sprinklers are used on systems that are seasonably drained to avoid freezing (e.g., vacation resort areas) NOTICE Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved TY3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-E LPCB Approved Reference No. 094a/11 CE Certified Certificate of Conformity No. 0832- CPD-2015 (Refer to Tables A and B for details.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1 inch NPT ISO 7-R 1 Discharge Coefficient K=5.6 gpm/p5i112 (80,6 1pm/barl/2) Temperature Ratings Refer to Tables A and B. Finishes Sprinkler: Refer to Table D. Escutcheon: Refer to Table D. JANUARY 2015 Physical Characteristics Inlet.........................Copper Plug ........................Copper Yoke ..................Stainless Steel Casing ........Galvanized Carbon Steel Insert .......................Bronze Bulb Seat ..............Stainless Steel Bulb (5 mm dia.) ................Glass Compression Screw............Bronze Deflector.....................Bronze Frame .......................Bronze Guide Tube.............Stainless Steel Water Tube.............Stainless Steel Spring.................Stainless Steel Sealing Assembly.......Beryllium Nickel w/TEFLON Escutcheon .............Carbon Steel TFP500 'TFP5eo Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURA B SSL RASS PLATED POLYESTER* PENDENT (TY3255) STANDARD 135°F(57°C) Orange 12,34,5,6 1,2,4,5,6 155°F (68°C) Red 175-F (79-C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2, 3, 6 1, 2, 6 RECESSED 135°F (57°C) Orange 1,2,3,5 1,2,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green 286°F (141°C) Blue 1,2 360°F (182°C) Mauve N/A DEEP 135°F(57°C) Orange 1,2, 3, 4, 5 1,2, 4, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve WITHOUT 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1,2, 3 1,2 UPRIGHT (TY3155) WITHOUT 135°F (57°C) Orange 1, 2, 3, 4, 5 Blue 1, 2, 4, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green 286°F (141°C) 360°F (182°C) Mauve 1, 2, 3 1,2 Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01 -E Approved by VdS Frame and deflector only N/A - Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS 4 TFP500 Page 3 of 10 SPRINKLER FINISH SPRINKLER ESCUTCHEON TEMPERATURE BULB TYPE TYPE RATING COLOR CODE NATURAL BRASS CHROME PLATED POLYESTER*** 135°F(57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow STANDARD 200°F (93°C) Green 286°F(141°C) Blue 360°F (182°C) Mauve 135° F (57°C) Orange 155°F (68°C) Red HSW* (TY3355) DEEP 175°F (79°C) Yellow 1**, 2**, 3*** 4,5 1** 2°, 4 5 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow WITHOUT 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1**, 2**, 5 2** Notes: 1 Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (1-PCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-E * Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches (100 to 300 mm) ** Light and ordinary hazard occupancies only Light hazard occupancies only Frame and deflector only TABLE B SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER TUBE ,- CASING GUIDE TL_- - INSERT TUBE NN 1i9 BULB FRAME SEAT 5 mm BULB VENT HOLE - COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY WRENCH RECESS WRENCH FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 WRENCH TFP5UO Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4"(6,4mm) INCREMENTS 1 I iFACE OF CEILING 2-3/16 ± 1/8" 3" DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING 13/8827/8 DIA. (34,9 ± 3,2 mm) FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" h(88,9 mm) - (12,7 to 1168,4 mm) I IN 1/4 (6,4 mm) 2-1/2" DIA. INCREMENTS I (63 5 mm) LEE FACE OF CEILING 4-1/4" ± 1/8" (108,0 ±3,2 mm) FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING - SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT (TY3155) WITHOUT ESCUTCHEON ORDER LENGTHS: 2-3/4 to 48" (69,9 to 1219,2 mm) IN 1/4 (6,4 mm) INCREMENTS 2-3/8" ± 1/8 1-i14 UI/ (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16 CRITERIA SECTION) OF WATERWAY (7,9 mm) IA. nm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2 to 45-3/4' (12,7 to 1162,1 mm) IN 1/4 (6,4 mm) INCREMENTS 4-1/4..± 1/8' ' 2-1/2" DIAH FACE OF (108,0 ± 3,2 mm) FACE OF (63,5 mm) fl MOUNTING SPRINKLER FITTING SURFACE I 1/J (8 SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48' (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 2-1/4" (57,2 mm) FACE OF - DEFLECTOR TO - SPRINKLER I MOUNTING URFACE SURFACE 5/16" / SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON TFP500 Page 5 of 10 Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Ref. Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow- ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble listing or approval agency (e.g., UL Listing is based on NFPA 13 require- ments). For more information on LPCB Approval, contact Tyco Fire Suppres- sion & Building Products at the follow- ing office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 inch NPT Series DS-1 Dry-type Sprinklers in the 1 inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. TFP5O Page 6 of 10 Temperatures for Heated Area(1) Ambient Temperature 40°F (4 C) 50:F (10 C) 60:F (WC) Exposed to Minimum Exposed Barrel Length(2), Discharge End of Sprinkler Inches (mm) 40°F (4°C) 0 0 0 30°F (-1°C) 0 0 0 20°F 4 0 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS You can also install Series DS-1 Dry- type Sprinklers in the 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1 inch NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 inch reducing tee when locating Series DS-1 Dry-type Sprinklers directly below the branchline; otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprin- klers and the branchline. Failure to do so may result in pipe freezing and water damage. ,'L.1tL.i Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Tyco Fire Protection Products (TFPP) Technical Services. Failure to use the appropriate fitting may result in one of the following: failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Pro- tection Association for dry pipe sprin- kler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when con- necting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprin- klers must be sealed. Due to tempera- ture differences between two areas, the potential for the formation of conden- sation in the sprinkler and subsequent ice build-up is increased. If this con- densation is not controlled, ice build-up can occur that might damage the dry- type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP500 Page 7 of 10 FACEOF SPRINKLER - - FITTING 7 EXPOSURE ________ LENGTH (SEE DESIGN. DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 11 EXPOSURE LENGTH RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER STRUCTURES -1c )Lj FIGURE 12 SPRINKLER FITTING UNHEATED AREA TO WET 11 SIDE SYSTEM I I OUTLET PLUGGED maim I DSB-2 SPRINKLER INTENDED I FITTING FOR FREEZER I I (SEE DESIGN CRITERIA STRUCTURES SECTION) ~Tz -.X-- li FIGURE 13 SPRINKLER FITTING HEATED AREA STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE lAs 1-3/4 DIA. (44,5 mm) LEARANCE HOLE NSULATED FREEZER TRUCTURE DS-1 HOWN WITH sTANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE BOOT STRAP TIES (ENDS ON DS-1 OPPOSING SHOWN WITH SIDES OF STANDARD BOOT) ESCUTCHEON FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 8 of 10 Installation TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers must be installed in accordance with this section. General Instructions Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Notes: Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendicu- lar to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 1. With a non-hardening pipe- thread sealant such as TEFLON applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Ref. Figure 1) the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 2) Apply the wrench recess of the W-Type 7 Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutch- eon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response, Standard Cover- age Dry-type Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP500 Page 9 of 10 P/N* 60 - XXX - X - XXX SIN SPRINKLER ESCUTCHEON FINISH FINISHI1) 96 Pendent with TY3255 CHROME SIGNAL WHITE Standard Escutcheon (1" NPT) (Figure 3) 0 PLATED (RAL9003) - Pendent with 93 TY3255 POLYESTER Deep Escutcheon (1" NPT) (Figure 5) NATURAL SIGNAL WHITE - Pendent with TY3255 1 (RAL9003) 97 POLYESTER BRASS Recessed Escutcheon (1° NPT) (Figure 4) - ________________ 92 Pendent without TY3255 2 NATURAL BRASS Escutcheon (1° NPT) (Figure 6) BRASS PLATED 94 4 (RAL9003) (RAL9003) SIGNAL WHITE SIGNAL WHITE POLYESTER POLYESTER CHROME CHROME PLATED PLATED TEMPERATURE ORDER I J Escutcheon (1° NPT) (Figure 7) 0 RATING(2) F1 LENGTH(} I Upright without TY3155 I - - ________________ 135°F (57°C) Notes: 1 155°F (68°C) Escutcheon Finish applies to sprinklers provided with escutcheons. 360F (182C) temperature rating applies to non-recessed sprinkler assemblies. 2 175°F (79°C) Dry-type Sprinklers are furnished based upon 'Order Length" as mea- sured per Figures 3 through 10, as applicable, and for each individual 3 200°F (93°C) sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. - * Use Prefix "I" for ISO 7-R1 Connection (e.g., -60-961-1-1801. 4 286°F (141°C) 5 360°F (182°C) TABLED SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION Sidewall with TY3355 Standard Escutcheon (1" NPT) (Figure 8) 53 Sidewall with TY3355 - Deep Escutcheon (1° NPT) (Figure 9) Sidewall without TY3355 54 Escutcheon (1' NPT) (Figure 10) 055 5,50" 082 8.25" 180 18,00" 187 18,75" 372 37,25" ' 480 48,00" Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Dry-type Sprinklers When ordering Series DS-1 5.6K Pendent, Upright, and Horizontal Side- wall, Standard Response, Standard Coverage Dry-type Sprinklers, specify the following information: SIN: TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Order Length: Dry-type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections: 1 Inch NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Tyco Sales Representative.) Temperature Rating Sprinkler Finish Escutcheon Type and Finish, as applicable P/N from Table Part numbers are for 1 inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhe- sive (a sufficient quantity for installing one boot). TFP500 Page 10 of 10 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. tqca TEFLON is trademark of the DuPont Corporation. Fire Protection Products tqccs Worldwide I Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/barl/2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 2-7/8" (73,0 mm) DIA. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2' 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 t (11,1mm)___NOMINAL (50, 11' Ll MAKE-IN mm) (50,8 mm) L_~u (34,9 mm). WP 2" 1-3/8" _ 1/2' NPT** DEFLECTOR* STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) ___________ ______________ FLUSH 3 1 3/8±5/16" (9,5±7,9 mm) 17 i-1 MOUNTING (3/8,2 ] mm) SURFACE CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" 1/2(12,7mm) (7,9±6,4 mm) FLUSH 17, 1/8" J MOUNTING (3,2 mm) SURFACE/ \__ CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY "TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 PIN*77_XXX_X_XXX I SPRINKLER TEMPERATURE I FINISH -J- I RATINGS SIN 1 NATURAL BRASS I 370 I 5.6K UPRIGHT (1/2'NPT) TY313 3 PURE WHITE (RAL9010)** 155 155-F (68-C) POLYESTER 371 5.6K PENDENT (1/2NPT) TY323 4 SIGNAL WHITE (RAL9003) POLYESTER Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - ** Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F(141°c) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. t cc TEFLON is trademark of The DuPont Corporation. 11Fire Protection Products r I U Malleable Iron Threaded Pipe Unions Pressure . Temperature Ratings Temperature _____________ Pressure Class 150 Class 250 Class 300 (° (°C) psi bar psi bar psi bar -200 to 1500 -28.90 to 300 20.7 65.60 500 34.5 600 41.4 2000 9330 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 28.6 4000 204.40 110 7.6 270 18.6 25.5 4500 232.20 75 5.2 315 21.7t 280 19.3 225 15.5 22.4 5000 260.00 - - 287.8° 180 12.4 550° - -130 9.0 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where tempeoture exceeds 450F c®Us APPROVED For Listings/Approval Details and Limitations, visit our webEite @ www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ Sizes '/-1" (6-25 mm) Sizes 11A"-2" (32-51 mm) Sizes 2h/2 3" (64-76 mm) (°F) (°C) psi bar psi bar psi bar psi bar .200 to 1500 -28.90 to 65.60 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 200° 93.3 265 18.3 1 1,785 123.1 1,350 93.1 910 62.7 250° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 300° 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 5500 287.8 - - 300 20.7 1 300 20.7 300 20.7 Ij Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. CZ ALL ELBOWS & TEES %" (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) www.anvilintl.com 17J I I 1 ____ a 0'r BULL VILJLJ Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 c®us LISTED <> APPROVED I] 4!!4 NFPA s=::on 2 im BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED APPROVED Do 4 ONFSA F,,. NFPA' ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Liyhtwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. el— c®us LISTED <*> APPROVED NFPA o" SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. SIZE (IN) (IN) I.D. (IN) CRR** WATER FILLED WEIGHT/FT WEIGHT BUNDLE SIZE 1 _l 315 1.097 1527 1.41 lbs/ft j _j80 - 91 1-1/4 1 [16ö1 L12 I 991 j [il It7ffJ 1 2518 6 1 11/2 190O i682 _776 - L 209 lbs/ft 61 EIIlTTIJ I 75 2 -172 ___875' 157 6 27j J 492 r_2641bs/ftl 223 1L 353I6iift _5893 _37 1 _30 r_3260 ]1 354 ]L_44I5ift1L_7957 ii_19T11 400 - 4.260 250 562Ibs7ftij11796 1 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. SIZE (IN) (IN) I.D. (IN) CRR** WATER FILLED WEIGHT/FT WEIGHT BUNDLE SIZE 1 1315 _L1°9 _ 100 1681bs/ft i .5_ 70 E4iIJIJ_1660J igooThThJ_100 [ 1380 _J [ 227 Ibs/ r_2i 8j 272 16 3.602 _51 _-44 2375 -1_2 —jI_1_oO 1fl6 I6i1f 7[ 5T14 T3° 2875Th468 100 L_3*_3500 JI_3068JL_100 r758FftL 10783 4* 4.500 4.026 1.00 10.801bs/ft 16.316 19 - *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas D( Masurt OH BULL MOOSE lUBE COMRANV 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. FireLock® Outlet-I ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 114 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para__________ Location Date Approved www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK or VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV C lq~ A-c-ta-ulicr 10.52 1 DIMENSIONS IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I STYLE 922 Nominal Size inches/mm Hole Diameter Dimensions - I nches/milli meters Run X Branch +0.6~41~5 FPTt - 1¼ 1h 1 3A6 '130 183 110 387 256 10 32 15 302 330 465 279 98.3 65.0 0.45 '/4 1 3/16 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1 ½ ½ 1 ,5o 1.42 1.95 1.22 4.08 2.56 1.2 x 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 '/4 1 3/io 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0,54 1 1/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 1 31.0 103.6 65.0 0.59 2 1/2 1 3A6 1.66 2.19 1.46 4.60 2.56 1.3 x 50 15 30.2 42.2 55.6 371 116.8 65.0 0.59 '/4 11/6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 1168 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 -30.2 47.8 645 37.1 116.8 65.0 0.68 - 2112 ½ 13A6 1.91 2.44 1.71 5.40 2.56 1.6 x 65 15 30.2 48.5 62.0 1 43.4 137.2 1 65.0 0.73 3/4 1 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 13A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 112 P1,6 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1 3/16 1.89 2.44 1.71 5.50 2.56 16 20 30.2 48.0 62.0 43.4 139.7 65.0 073 1 1/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NFl or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAUUC COMPANY. ALL RIGHTS RESERVED. 30.52 2 Jtauuicr RFV ( IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS J.U.3 PERFORMANCE Run Size x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT Inches/mm Feetlmeters 32 25 x 40 25 I. 8.5 6S 25 4.2.6 * Hazen-Williams coefficient of friction is 120 FireLock® Outlet-T STYLE 922 www.victaulic.com XAi-c—ta—ulicr VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PFV r 10.2 3 FireLock® Outlet-T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2009 VICTAULIC COMPANY, ALL RIGHTS RESERVED. 1052 \%taulicr P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 Inch pipe LISTED FOR STEELICPVC 1/2 & 3/4 Inch pipe 5 thru 8 Inch pipe NFPA 13 PIPE ROD I Wi, 5 WT.+250 UL TEST LOAD 1 1 3/8 3075 403.75 750 1 1/4 1 3/8 43.95 469.75 750 11/2 1 3/8 54.15 520.75 750 2 3/8 76,95 634.75 750 21/2 3/8 118.35 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 112 476.35 .75 2650 8 1/2 711.00 3805.00 4050 SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - c®85 203-EX 2551 1"- 8" USTED Ae> Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resetting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIM ER. AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to toss of business or profit, when non-AFCON products have been, or are used. 1/08 Product Features -No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. 1/4" 8003957 GST 200 1/4 x 2 1760 (Fir) 25 125 I 1/4' 8004957 GST 300 1/4x3 2060 ______ 25 iJ 3/8" 8006957 GST 75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/8 8007957 GST 10 1/4 xl 210 (7/1605B) - 300 25 ::l5 ] 3/8" 8008957 GST 20 1/4x2" 1760 (Fir) 850 1475 25 125 3/8" 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 !' 3/8 8010957 GST 30 1/4x3 2060 (Fir) 1500 - 1475 25 125 1 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 3/8 8011925 GST 40 1/4x4 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 1/2 8013925 GST2 1/4x2 1760 Fir) _25 125 1 1/2" 8014925 GST 2.5-380 3/8x2-1/2 2113 (Fir) 25 125 8015925 GST3 -1/4 x3 2275 F7r) 25 125 1/2 8016925 GST4 1/4x4" 2180 (Fir) 25 125 8017925 GST6 1/4x6" 2230 (Fir) - 25 Product Features Eliminates distortion of threaded rod. "Saves time from traditional methods. Accommodates up to 3 x 12 pitch roof. • Reduces installation cost Allows 17" deflection from vertical. • Made in the U.S.A. 3/8 8139957 SHGST20 1/4x2 1 1257 (Fir) 1050 1475 25 125 3/8' 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the tJI H ULI FlII #14 Black Nut Driver Part # 8113910 a #14 Black Nut Driver Part #8113910 Ii #14 SW Red Nut Driver Part # 8114910 IN Floor Joist Product Features No pie-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost 'Made in the U.S.A. Not less than 2' nominal width (1.1/2') up to 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe 4 Minimum 2-1/2' from bottom for branch lines, Minimum 3' from bottom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing ships resting on top of steel beams. I #14 SW Red Nut Driver Part # 8114910 114" 8018957 SWG 100 1/4x1 622Jfji 25 1.251 1/4" 8019957 SWG 200 1/402' 1725 (Fir) 25 125 - 8020957 SWG 10 1/4x I 622_() 300 25 125 J / 3/8" 8021957 SWG 20 1/4x 2" 1725 (Fir) 1050 25_ 125 QuA ic 3/8' 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 hR 8023925 SWG 30 1/4x3 1884 (Fir) 25 125 Rf$,'. i h' VERTICAL •,,:- HORIZONTAL i ,ri_, . Insert the appropriate nut driver into a 3/8' or 1/2" portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2' or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. I. Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. @ Me Ls-ka'!", SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.