HomeMy WebLinkAbout2800 WHIPTAIL LOOP; 105; FPC2020-0079; PermitPERMIT REPORT ((7c ity of Carlsbad Print Date: 01/05/2021 Job Address: 2800 WHIPTAIL LOOP, # 105, CARLSBAD, CA 92010-6751 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2091202500 Track #: Valuation: $184,458.66 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0079 Status: Closed 7 Finaled Applied: 04/21/2020 Issued: 05/05/2020 Finaled Close Out: 07/06/2020 Inspector: Final Inspection: Project Title: Description: PACIFIC VISTA COMMERCE -REVISED PLANS FOR ADDING ONE RELAY & 2 DUCT DETECTORS TO THE EXISTING MONITORING SYSTEM FPContractor: THE STEINHILBER CORPORATION 533 S VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Sprinkler Monitoring $383.00 Total Fees: $678.00 Total Payments To Date: $678.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Pfczo2ô O 0 +c Irmflop EH7EFppmEs FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS PACIFIC VISTA COMMERS CENTER SPEC SUITE C-4/C5 TENANT IMPROVEMENT 2800 WHIPTAIL LOOP W. CARLSBAD, CA FIRE ALARM SYSTEM MATERIAL DATA SHEETS FIRE ALARM SYSTEM BILL OF MATERIALS NOTIFIER NC-100R ADDRESSABLE RELAY MODULE CSFM# 7300-0028:0230 SYSTEM SENSOR INNOVAIRFLEX DNR DUCT DETECTOR HOUSING WITH SMOKE DETECTOR HEAD CSFM# 3242-1653:0209 NC-100R(A) Relay Module for FireWarden Series Panels General The NC-i OOR(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. dn-60383:A2 NOTIFIER® by Honeywell NC-1 OOR(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5 (11.43 cm) high x 4° (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125 (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5m5) Coded 30 VDC 0.5 A Inductive (LJR=2ms) Coded 30 VDC 1 1.0 A Inductive (PF=0.35) INon-Coded 125 VAC I 0.5A dn-60383:A2 • 06/17/10 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ULIULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I O 9001 We try to keep our product information up-to-date and accurate. K22 =6 ZIN a • • We cannot cover all specific applications or anticipate all requirements. BGINFBlING I MMURIM111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonchoneywelI.com DESIGN: Models NMM-IOOP, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM..1006 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60429:C1 DNR(A)/DNRW InnovairFiex Intelligent Non-Relay Photoelectric Duct Smoke Detector General The Notifier InnovairFIex® DNR(A) intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 70°C), and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Notifier InnovairFIex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFIex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFiex product line is compatible with all previous lnnovair models, including remote test accessories. Features Photoelectric, integrated low-flow technology. Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/s). Versatile mounting options: square or rectangular configu- ration. Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non-condensing). Patented sampling tube installs from front or back of the detector with no tools required. Cover tamper signal. Increased wiring space with a newly added 3/4" conduit knockout. Available space within housing to accommodate mounting of a relay module. Easily accessible code wheels on sensor head (sold sepa- rately). Clear cover for convenient visual inspection. Remote testing capability. Requires corn line power only. Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. NOTIFIER® by Honeywell Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm): Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 1580F (-20°C to 70°C). Storage Temperature Range: -22°F to 158F (-30°C to 70°C). Operating Humidit Rarge: 0% :o 95% relative humidity (non-condensing). Air Duct Velocity: 1'0 to 4,000 f1m1n (0.5 tc 20.32 m/s). Accessories Notifier provides system flexib Iity with a Jariey of accessories, including two remote test sta: onE ard different means of visi- ble and audible system annuncia7ion., As with ou duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS 4T24 VDC Device Standby Alarm RA100Z OmA I' 12 mA Max RTS15I/ OmA 12mA Max RTS151KEY Agency Listings and Approvals Consult product manual for lists of compatibe UL-Listed devices. In some cases, certan mdLles may no-., be listed by certain approval agencies, or I sting maybe in process. Con- sult factory for latest listing staTus. UL: S911, S3705. ULC: S635. UN-60429:C1 • 4/19/2312 -Page 1 of 2 CSFM: 3242-1653:0209. FM approved. Product Line Information NOTE: "A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851 R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DSTi(A): Metal sampling tube duct width up to 1 ft (0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RAiOOZ(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS1 51 KEY(A): Remote test station with key lock. Important Note DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 ______________ We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. M99 QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60429:C1 • 4/19/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-1653:0209 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01 -02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division f:-O- cxY49 dn-60383:A2 NC-100R(A) Relay Module for (a NOTIFIER® FireWarden Series Panels by Honeywell Addressable General 4 The NC-100R(A) Addressable Relay Module provides NOTI- FlER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED 'blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-1 00-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-1 OOR(A) maybe programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-1 OOR(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. 11 Z4 _;11, NC-i OOR(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 450 (11.43 cm) high x 40 (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 40 (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2 • 06/17/10 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-11 OOR: Intelligent addressable relay module. NC-1 OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. -- . -- -- I so ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 933=1=1 We cannot cover all specific applications or anticipate all requirements. INIMIGIMMIMMS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL mls~ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotiflerOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM..1006 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division