Loading...
HomeMy WebLinkAbout5840 EL CAMINO REAL; 102; FPC2016-0017; PermitCARLSBAD, CA Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Print Date: 03/02/2022 Job Address: 5840 EL CAM INO REAL, # 102, Permit Type: FIRE-Construction Commercial Parcel #: 2090503200 Valuation: $45,578.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2016-0017 Status: Closed - Finaled Applied: 11/21/2016 Issued: 11/22/2016 Finaled Close Out: 02/22/2021 Inspector: Final Inspection: 2 Oki II11ZI']i (City of Carlsbad Project Title: Description: CARLSBAD CORPORATE CENTER: SPRINKLER TI (66 HEADS) SUITE 102, 105, 106 TI - COMM HG FENTON: 4415 SF TI, CREATE SUITE 102 FROM SUITE 1071/ ACTUAL AREA OF WORK 2697 SF, FEES SPLIT ON 3 PERMITS (SEE CB163779 &CB163780) Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION INC JAllMIN DEEKEN 9925 PROSPECT AVE, # B SANTEE, CA 92071 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 ___________ Sizes '/'-1" (6-25 mm) Sizes 11/"_2" 32-51 mm) Sizes 24'-3" (64-76 mm) (°F) (°C) psi bar psi bar psi bar psi bar -200 to 1500 -28.90 to 65.60 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121,1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 3500 176.7 150 10.3 1,150 79.3 1 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 5500 287.8 - - 300 20.7 300 20.7 300 20.7 CO 'Cu C.) 0 (I) - 10 Cu E 0. Anvil Class 150/300 Malleable Iron Fittings conform to ASME . B16.3 and Unions conform to ASME 816.39. ALL ELBOWS & TEES % (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) " 3 ,3 PF-11.10 IE .0 co 7, t . Eu- /cn (0 FPC20I6-001 L) co w 5840 EL CAMINO REAL D UNITI02 ) 05, pa c o ozj LZ Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Cl2ss 300 (°F) (°C) psi bar psi bar psi bar -200 to 1500 -28.90 to 300 20.7 65.6° 500 34.5 600. 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 400° 204.40 110 7.6 270 18.6 370 25.5 450° 232.2° 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 5500 287.80 - - 130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended I )r use erere temperature exceeds 450°F c®Us APPROVED For Listings/Approval Details and Limitations, visit o'ir website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. - 4g Owl : .. ANfdIAIDD 38fl± ESODIAI 11fl9 I I r - WAN FN O]AOHddV :4 . O31SIT SR®3 14 jA.JSnpUI eq Ul did JP1ULJdS aseq LI L.V • ..• b'3 ?; c®us LISTED <9> APPROVED Mo Z49A!Ei4 NFPA s= 2 71 ull Moose Tube® is a customer focused, Ugrowth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 4 - 800.325.4467 BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED APPROVED ZA, 4N 0 NFSA NFPX s,o:w. ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. c®us LISTED <> APPROVED no A ONFSA NFPA SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE t l 1.315 - - 1.097 L 1527_L41Ibs/ft L 1820 91 L__fl/4 II 16U jL__j 442 J 991 _::]r-1.V1flIbffil 2 518 i[......_ 11T2 1900 1.682 776 2091bs/ft 3.053 61 TTT1 1L 1i 2.64 ! .223 37 21/2 492 - 353 lbs/ft - 5.993 30 3.54 _4 FEN - 4 4.500 4.260 2.50 5.62 1bs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 °l-i81r llo ]r 2.27 ibs/ftj2918 - - 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 - 44 EIII _IlL_ _JE2 O67J 1001 1bs/ft L91 L 9Ii1 21/2* I - 2875 2468 100 5801W4t - 7.875 30 - ]500 I[_3068 1.00 1LiL _ici 'L Ti iTi 4* 4.500 4.026 100 10801bs/ft 16316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. co For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com ) Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grand AZ Dallas, D( Masury, OH OLH-L MOOSE WEE COMPANy 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. FireLock® Outlet-T <&> ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11% through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWN ER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com - - vIcTAuLIC IS REGISTERED TRADEMARK OF VICTAuLIc COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ICtaUlIC REV G 1.0.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1U.3 1¼ ½ 1/i& 1.30 1.83 1.10 3.81 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3/4 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1/I6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 1/2 1 3/16 1.42 1.95 1.22 4.08 2.56 1.2 x 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1 3A6 1,40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 /l6 1.64 2.30 1.22 408 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 1/2 1 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 422 55.6 37.1 1 116.8 65.0 0.59 34 1 /io 1.64 2.19 1.46 4.60 2,56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 3/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116 65.0 0.68 2½ ½ 1 1/16 1.91 2,44 1.71 5,40 2.56 1,6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1/16 1.89 2,44 1.71 5,40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 1/2 13A6 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 34 13A6 1,89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 620 1 43.4 139,7 65.0 0.73 1 11/16 2.13 2.79 1 1.71 5.50 2.56 1.7 25 1 30.2 1 54.1 70.9 43.4 139.7 65.0 0.80 FireLock® Outlet-I STYLE 922 DIMENSIONS L .I '1uV L1 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1052 2 j1'tauIic" REV r IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1U.3 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams Coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. iCtUI.0 RFV C, 10J2 3 FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com A_C_tauhc~ 10.52 3355 REV G UPDATED 12/2009 vICTAULIC IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY, © 2009 vlc'rAuUc COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC II2&3/4 Inch pipe 5 thru 8 Inch pipe SIZE - ROD- 3/8 or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - LISTED 203-EX 2551 1"- 8" ..Approval guide - I"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I WT. 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 634.75 750 21/2 3/8 118.35 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 148000 1500 5 1/2 349.45 1 1996.75 2000 6 1/2 476.35 1 2631.75 2650 8 1/2 711.00 1 3805.00 4050 Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. 551 5.. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. S.' 'V Specific ,4FC0N products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer at hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON wilt NOT warrant against the failure of its products when used in combination with oilier products, parts or systems not manufactured or said by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to toss of basiocss or profit, when non-AFCON products have been, or are used. 1/08 J I Not less than 2' nominal width Wood Flooring Product Features 11-14 No pie-drilling required. Not less than Quick to install using the Sammy 3" nominal Nut Driver with an 18V cordless Of, thickness (2-112") ldepth or side Wood Joist drIll/drIver. of vertical member) _____________________________ Saves time from traditional Double Sheetrock methods. Ceiling Reduces installation cost II "Made in the U.S.A. -,==M =am . EIV 12% 1/4" 8002957 GST 100 1/4 X1" 25 125 1/4" 8003957 GST 200 1/4x2° 1760 (Fir) 2b 125 - 104 Black Nut Driver Pad #8113910 -1y5- ° 8004957 GST 300 1/4 x 3" _(Fir) 25 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/6.8007957 GST10 114x1" 210 (7/16OSB) 300 25: 1251 3/8" 8008957 GST 20 1/4x2" 1760 (Fir) 850 1475 25 125 Et. 3/8 8068925 GST 20-SS 1/4 x 2 1760 (Fir 850 25 3/8 8009925 GST 25-380 3/8 x 2-1/2° 2113 (Fir) 1500 25 125 V 3/8 8010957 GST 30 1/4 x 3° 2060 (Fir) 1500 147525 125 j 3/8 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4x4" 2180 (Fir)25 l25] 3/8" 8012925 GST 601/4x6"2230(Fir)25125 - 1/2° 8013925 GST2 114x2"1760(Fir)251251 1/2"8014925GST 2.5-3803/8x2-1/2"2113 (Fir)25125 172°8015925GST 3 1/4x3"2275(Fir) 25 i Fi 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 #14SWRed 1/2" 8017925 GST6 1/4x6° 2230 (Fir) 25 125 j __- Nut Driver Part# 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 '/" x 12 pitch roof. • Reduces installation cost. Allows 17° deflection from vertical. • Made in the U.S.A. ruu rdi LApprovaIsSize N Modet _819957SH.014 2"_1257 (Fir) 1050 1475 25_1251 3/8 8141957 SN-GST 30 1/4x 3° 1720 (Fir( 1500 1475 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to:datejhfdrmAtion~ visit www.sammy~~perscrew.com WHS #14 Black Nut Driver Part # 8113910 11PA'S Li Not less than 2" nominal width / . . - - Product Features (1.1/2 ) up to 3-1/2" pipe; not lens than - - - - . No pre-drilling required. 3" (2-112') nominal width 4 & 5" pipe 4 Floor Joist Quick to install using the Sammy Minimum 2-1/2" from bottom for / - branch lines. Minimum 3" from Nut Driver with an 18V cordless I bottom for main lines. Exception: This drill/driver. requirement shall not apply to 2" or thicker nailing oh/pa resting on top of steel beams. Saves time from traditional methods. Reduces installation cost. ii I..- . . Made in the U.S.A. --" _--i lL_I_.i• J'.. . -. 1/4x1 622 (Fir) 25 125 1/4x 2" 1725 (Fir) 25 125 1/4x1' 622 (Fir) 300 25 125 1/4x2" 1725 (Fir) 1050 25 125 1/x2 1725 (Fir) 850 25 125 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 114x3 1884 (Fir) 25 125 8018957 SWG 100 1/4" 8019957 SWG 200 E 114" 8020957 SWG 10 - - 3/8 8021957 SWG 20 8073925 SWG 20-SS #14 SW Red . 3/8" 8022925 SWG 25-380 Nut Driver SWG 30 Part # 8114910 [INSTALLATION STEPS -INTO WOOD & STEEj FNSTALLATION STEPS .I INTO WOOD &STEELI Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8' 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in puffin steel. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 114", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a last and safe installation each time. When the face of the driver comes into contact with the mate/al you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.