Loading...
HomeMy WebLinkAbout2405 COUGAR DR; ; FPC2019-0099; Permit:J iiriiii i E1I]f4I (city of Carlsbad .- M ILrLe1aeimit Print Date: 04/11/2022 Job Address: 2405 COUGAR DR, CARLSBAD, CA 92010-8804 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2090404200 Track #: Valuation: $5,019,763.48 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0099 Status: Closed - Finaled Underground Fire Applied: 04/18/2019 Issued: 05/30/2019 DEV2017-0088 Finaled Close Out: 09/21/2020 Inspector: Final Inspection: Project Title: WEST COAST SELF STORAGE -CARLSBAD Description: WEST COAST SELF STORAGE -INSTALL PRIVATE FIRE SERVICE LINE AND 2 HYDRANTS Applicant: Contractor: HOWES WElLER LANDY PLANNING AND LABRUNA CONSTRUCTION INC ENGINEERING DEE DEVEY JOSE SANCHEZ 19712 MACARTHUR BLVD, # STE 200 2888 LOKER AVE E, # 217 IRVINE, CA 92612-2407 CARLSBAD, CA 92010-6685 (949) 939-0194 (760) 929-2288 FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $136.00 FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $892.00 Total Payments To Date: $892.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov S. ' Foxtail Loop PRS ~-o - Y 10. e Proposed 12" PVC Waterline 0 7. 44 Fire Flow Test Location e Project Site C 744 Legend C w_Hydrant Pipe ZONE -375 -430 -490 -550 U e 14, -S I 8j 2 8. Cougar Drive - Fire Flow Analysis to No. 94c CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Cougar Drive at El Camino Real I SR#: (Assigned upon plan submittal) PROJECT ADDRESS: APN 029-041-42-00 CITY: Carlsbad PHONE: ( 858 ) 677-9278 (Response Fire Protection Company, Inc.) FAX NUMBER: (858) 459-3418 Largest Building (It.2): 83,712 Sprinkled? Yes Construction Type: Ill-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): CougarDrivenorthwestofElCaminoReal TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 103 PSI Hydrant Number (if applicable):(nodeJ92) Pressure Zone: 490 Feet Main Size: 12 INCH Elevation of test: 252 Feet Date/Time of Test': Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 3,500 GPM Residual Pressure104 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this flow exceeds the District's maximum pipeline velocity of 10 fps. The maximum fire flow that meets both the velocity and pressure criteria is 3,500 gpm. No specific fire flow was pro vided for testing. 1Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable):C69606 Signature:? Piect ____________________________________ Title/Or Manager Date: 05/07/2019 DESCRIPTION: C900 PVC Pipe MANUFACTURER(s): Diamond Plastics SPEC SECTION: COMMENTS: Factory Mutual Systems APPROVED ®Underwriter Laboratories Inc.,© Property Specific Gravity Tensile Strength, psi Tensile Modulus, psi IZOD Impact Strength ASTM Test D792 D638 D638 D256 Minimum 1.40 7,000 400,000 .65ft., lb./in Diamond (C900) PVC Pipe (4"through 12") is made of 12454 compound per ASTM D1784, in accordance with the dimensional, chemical, and physical requirements of AWWA C900. Diamond (C900) PVC Pipe bears the mark of NSF, International (NSF), the listing of Underwriters Laboratory, Inc. (UL), and (DR1 4 & DR1 8) bears the listing of Factory Mutual(FM). Diamond (C900) PVC Pipe utilizes a gasket, per ASTM F477, to seal the integral bell socket to the spigot of the next joint (which conforms to the requirements of ASTM D3139.) Each male end is beveled to facilitate joint assembly, and the spigot is referenced marked to ensure proper insertion depth. Diamond furnished lubricant is to be used in the joining process. Diamond C900 is supplied in 20 foot laying lengths. SHORT FORM Specification for Diamond C900 PVC Water Pipe Diamond C900 PVC Water Pipe shall be made of compounds conforming to ASTM D1784 with a cell classification of 12454. Diamond C900 shall meet all the dimensional, chemical, and physical requirements as outlined in AWWA C900 and will be supplied in 20 foot laying lengths. Joints shall meet the requirements of ASTM D3139 and shall be formed using Rieber Technology. Gaskets shall meet the requirements of ASTM F477. Potable water pipe shall be manufactured from National Sanitation Foundation (NSF) approved compounds. DIAMOND 011 CORPORA PLASTICS® TION ap Corporate Headquarters 1212 Johnstown Road P.O. Box 1608 Grand Island, NE 68802-1608 ®UQO® O@ @ page,* age six Reiber Joint Illustration DIAMOND Q PLASTICS® C 0 R P 0 R A I I 0 N Corporate Headquarters 1212John5townRoad P.0. Box 16O8 Grandlsland,NE68802-1608 O®O® ®i v 00 page) MATERIAL SUBMITTAL DESCRIPTION: Tracer Wire MANUFACTURER(s): Regency SPEC SECTION: COMMENTS: I ® C ®uS 830 South West Street, Sikeston MO 63801 800-876-3020 I 573-472-2990 / FAX 573-471-3134 UF/TWU Irrigation Wire Description: Regency's single conductor UF/TWU Irrigation Wire is manufactured for the purpose of direct burial power wire applications in accordance with Article 339 of the National Electric Code NFPA-70. Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3 and B-8. Gauge sizes 18 thru 8 are solid conductors. Sizes 6 thru 4/0 are stranded conductors. The insulation is a high quality polyvinylchloride (PVC) for systems applications of up to 600 volts and conductor temperatures up to 60 C. The UF/TWU Irrigation Wire is constructed in accordance with Underwriters Laboratories, Inc. standard 493 and 83, as well as CSA 22.2 No. 75. Application: Suitable for use as power and control wire for irrigation systems. Construction: Conductor: Soft drawn bare copper (ASTM Spec. B-3 and B-8). Solid (18 awg to 8 awg) Stranded (6 awg to 4/0 awg) Insulation: Polyvinylchloride (PVC) Temperature: 60 C Voltage: 600 volts Conductor Size Insulation Thickness Colors 14 .060 1-12 12 .060 1-12 10 .060 1-9,11 8 .080 1-8 6 .080 1-5 4 .080 1,2,3,5 2 .080 1,2,3,5 1/0 .095 1,2,3,5 2/0 1 .095 1 1,2,3,5 Available Colors: 1-Black, 2-White, 3-Red, 4-Blue, 5-Green, 6-Yellow, 8-Orange, 9- Gray, 10-Pink, 11-Purple, 12-Tan. Material must be able to pass the following tests without showing signs of degradation: Cold Bend - The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to —25 C for four (4) hours. Electrical - AC test voltage, 60 seconds at 5000 volts. Sunlight Resistance Test - Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. MATERIAL SUBMITTAL DESCRIPTION: Detectable Tape MANUFACTURER(s): TChristys SPEC SECTION: COMMENTS: MAREUG TAPES DETECTABLE MARKING TAPE (1,000' ROLLS ARE STANDARD) Our DETECTABLE marking tape provides for easy buried pipeline detection and below ground identification and warning. The tape can be located below ground with a non- ferrous metal detector when buried at the proper depths. We recommend bury depths of: Tape Width Tape Bury Depth 6"-18" 6"-28" 6'-36- 6"-36" 6" 12" or wider TAPE MUST BE BURIED FLAT FOR MAXIMUM DETECTABILITY AND LINE PROTECTION. CONSULT YOUR SPECIFIC LOCATOR MANUFACTURER FOR BURIAL LIMITATIONS. Specifications Christy's'" DETECTABLE marking tape consists of a 5.0 mil (0.005") thickness; five-ply composition; ultra-high molecular weight; 100 percent virgin polyethylene; acid, alkaline & corrosion resistant. The tape tensile strength is in accordance with ASTM D882-80A and will not be less than 7800 PSI. Elongation properties are in accordance with ASTM D882-80A and are less than 150% at break point. Tape color & legend combination will be in accordance witl A E 18 A nr In P1 requirements. The color isiBlue The legend reads ICaUtIOn Water Line Buried Below The tape will have a 2.0 mil (0.0020") solid aluminum foil core, encapsulated within 2.55 mil (0.00255') polyethylene backing. Tape width shall be 10 I (For best results we recommend a tape width at least 3/4 of the diameter of the pipeline being protected. A 4" diameter line would use 3" or wider tape for optimum protection). Standard widths are 2", 3", 6'", & 12'. TA.DT.XX.XXX. (See model number designations on pages 221 & 222). 220 I I Cftrislj'c (800) 258-4583 0 www.tchristy.com I ©2oo9christ(s. All rights reserved. Pacing and specifications may change without notice MATERIAL SUBMITTAL DESCRIPTION: Poly-Sleeve MANUFACTURER(s): TChristys SPEC SECTION: COMMENTS: PRODUCT SPECIFICATIONS Manufactured of virgin polyethylene material 8 mu minimum, group 2, linear low density Black, Ed Purple, Blue or Green Conforms to the material requirements of the latest revision of ANSl/AWNAC105/A21.5-10 and ASTM D4976 and N14112-10 Film is imprinted every 18"-24" with: Trademark Yearof manufacture Type of resin Specification conformance Applicable pipe sizes Text "Warning Corrosion Protection - Repair any Damage". Purple Polywrap verbiage reads "Recycled/Reclaimed Water Line" Sizing Guidelines: Pipe Diameter/Polywrap Size" Through 6" 16" polywrap Through 8" 20" polywrap Through 10" 24" polywrap Through 12" 27"polywrap Through 14" 30"polywrap Through 16" 34" polywrap Through 18" 37" polywrap Through 20-24" 54" polywrap Through 30" 67" polywrap Through 36" 84" polywrap Through 42" 84" polywrap "Largersizes available upon request T. Christy Enterprises, Inc. 655 EBall Rd-Anaheim, CA92805 Tel: (714) 507-3300" Fax: (714) 507-3310 POLYWRA P (Polyethylene Encasement Tubing) Corrosion Protection for Cast Iron, Ductile Iron and Steel Pipe AWWA C105-10, ANSIA2I.5-10 For over 40 years polyethylene encasement has proven to be an effective method of protecting ductile iron pipe from corrosion. Tests have shown that when loose polyethylene encasement is installed on pipe, it provides an economical means of corrosion protection Polyethylene film prevents contact between pipe and the surrounding soil, however, it is not meant to be an air or water tight encasement For use on metal piping systems for identification and corrosion protection or PVC pipe for identification purposes such as Reclaimed/Recycled water Available Perforated every 20' or 22' for both 18' and 20' pipejoints or non- perforated for field versatility Diameters available to cover 6' through 42" pipe* Warning message repeats every 18-24 inches depending on size Printed with current AWWA C105 and ANSI A21.5 specification PROPERTIES Material Group 2 (Linear) Density 0.910 to 0.935 g/cm3 Class B (Colors)(1) Dielectric Strength Volume resistivity 101 50hm-cm . ,m in. Physical Properties Minimum Tensile Strength Minimum Elongation Minimum Dielectric Strength Impact Resistance Propagation Tear Resistance Thickness Colors Available 3600 PSI (24.8 M Pa- ASTM D882) 800% (ASTM 882) 800 V/mil (ASTM D149) Minimum 600 g (ASTM D1709 Method B) 2550 gf (ASTM D1922) Minimum of 0.008 in. (8 mils) Black, Clear, Purple, Blue, Green. INSTALLATION Install polywrap according to the latest AWWA or DIPRA guidelines. Use with Christy's Polyethylene (Visqueen) Fitting Wrap and Pipewrap Tape & PIPE WRAP TAPE -10 MIL DESCRIPTION Christy's Pipe Wrap tape consists of a stabilized, plasticized PVC film with a hightack adhesive backing. It provides a superior moisture and corrosion barrier on many types of piping uses, including both exposed and direct burial applications. Christy's'' Pipe Wrap tape provides op- timum protection when used in conjunction with Christy's Prime-It Pipewrap Primer (Prime-It" provides superior adhesion while increas- ing overall corrosion resistance). Product Code No. 205 - 202 - 204 pipewrap (413 printed vinyl identification tape). i6~ Thickness lOmils (0.25mm) Tensile Strength 9kg (25mm) Elongation at Break 200% Adhesion to Steel .56kg (25mm) Adhesion to Backing .56kg (25mm) Dielectric Strength 7000 volts Unwind Force 800g (25mm) PARTNUMBER._- TA-33-PWII X 10 MIL TA-33-PW2I X 10 MIL I TA-33-PW4I 4" X 10 MIL TA-33-PW2I SPECIFICATIONS & INDUSTRY LISTINGS Can be used on all types of pipe and fittings, including steel, galvanized, electrical conduit, cast and duc- tile iron. Christy's Pipe Wrap tape is listed by the International Association of Plumbing & Mechanical Officials (IAPMO) and carries the shield. Christy'sT Pipe Wrap tape: Provides excellent insulating capacities and superior abrasion resistance. Resists/reduces corrosion problems caused by salts, salt water, soil acids and alkalis. Provides a dielectric barrier between the pipe and soil. Resists common chemicals and vapors and protects against fungus and bacteria imany applications. Remains pliable in a wide range of temperature and working environments while providing increased UV and weathering protection. The physical and performance properties shown are averages obtained from tests recommended by ASTM-1000, or our own procedures. A particular roll may vary slightly from these averages. It is recommended that the buyer determine the suitability for his own purposes. Subject to c .. MATERIAL SUBMITTAL DESCRIPTION: Restraints MANUFACTURER(s): Star Product SPEC SECTION: COMMENTS: STAR®PIPE PRODUCTS PROJECT NAME. I ENGINEER. CONTRACTOR:! SPEC. SECTION: ® Q <9~> MIE IMIBE R WD AWWA O The design eliminates tie rods and thrust blocks and has been proven in the market since 1992. Can be used on 4-12" AWWA C900,14"-36" AWWA C905 PVC pipe or 3-12" IPS PVC pipe* ('fransition gasket required on IPS PVC Pipe 12" and under). Listed with Underwriters Laboratories in sizes 4-12" for use on DR 18 class 235 C900 PVC pipe at 150 PSI. Approved by Factory Mutual Research in sizes 4-12" for use on DR] 8 class 235 at 150 PSI and for sizes 4-10" DR1 4 class 305 C900 PVC pipe at 200 PSI. Tested to and meets the requirements of ASTM F1674 through 14' size for DR18 PVC pipe. The safety factor is twice (2:1) the standardized pressure rating listed on Page 18 of the catalog. Will fit any Mechanical Joint configuration, meaning compatibility with different types of installations. PVC Stargrip offers 50 deflection through 12", 30 on 14-24" and 20 on 30-36". Larger ID allows easier installation on out-of-round pipe. All sizes have curved wedges that will not flatten pipe. For use on HDPE or C909 pipe, please contact Star Engineering. Gland: Ductile Iron per ASTM A536, Grade 65-45-12 Wedges: Ductile Iron per ASTM A536, Grade 65-45-12 heat treated to a minimum of 370 BHN Wedge Finish: Thermally cured fluoropolymer epoxy coating GLAND FINISH OPTIONS (Please check one): Standard: alkyd enamel coating flOptional: StarbondTM IGIC polyester powder coating applied by an electrostatic spray process Optional: Other (specify) COUNTRY OF ORIGIN OPTION (Please check one): Import 100% Domestic' Domestic gland with import components' (Please see Domestic Restraint Options Available on our website.) REV.13-1 HARDWARE OPTIONS (Please check): E Standard: T-bolts are high strength low alloy steel manufactured in accordance with ANSI/AWWA C111/A21.11-00 Optional: 1-bolts and nuts alloy SS 304 per ASTM F593 F Optional: 1-bolts and nuts alloy SS 316 per ASTM F593 fl Optional: 1-bolts and nuts Fluoropolymer Star-Blue coated high strength low alloy steel manufactured in accordance with ANSI/AWWA Cl] 1/A21.1 1-00 STAR" PIPE PRODUCTS HOUSTON CORPORATE ITOLL FREE 1-800-999-3009 FAX 281-558-9000 www.storpipeproducts.com Page 1 PVC Stargrip®series 4000 Mechanical Joint Wedge Action Restraint for AWWA C900/C905 and IPS PVC Pipe Li rri El El El El 10 11.10 10.75 12 13.20 12.75 14 15.30 N/A 16 17.40 N/A 18 19.50 N/A 20 21.60 N/A 24 25.80 N/A 30 32.00 N/A 36 38.30 N/A All dimensions in inches except where indicated. - dimension after assembly on pipe 11.23 15.62 1 16.18 7/8 3/4(8) 8 23 13.33 17.87 18.18 7/8 3/4(8) 8 28 15.45 20.75 20.36 7/8 3/4(10) 10 50 17.55 23.00 22.46 7/8 3/4(12) 12 60 19.65 25.25 24.56 7/8 3/4(12) 12 65 21.75 27.50 26.66 7/8 3/4(14) 14 76 25.95 32.00 30.86 7/8 3/4(16) 16 98 32.18 39.38 36.82 1-1/8 1(20) 20 173 38.48 46.25 43.12 1-1/8 1 (24) 24 219 MAXIMUM rI WORKING PRESSURE RATING 41.1. WITH OCCASSIONAL & RECURRING SURGES 4.• - TECHNICAL INFORMATION 6" PVC Stargrip® Series 4000 for PVC Pipe - ' Please check sizes: NOM. C900/C905 IPS PIPE OD 1-BOLTS WEDGES APPROX SIZE PIPE CI OD (TRANSITION øA B CT øD SIZE (QTY) WI. GASKET REQUIRED) (QTY) (LBS) 3 N/A 3.50 4.09 1 7.69 8.50 3/4 5/8(4) 4 7 4 4.80 4.50 4.93 9.12 9.53 7/8 3/4(4) 4 9 6 6.90 6.63 7.03 11.12 11.63 7/8 3/4(6) 6 13 8 9.05 8.63 9.18 13.37 13.97 7/8 3/4 (6) 6 17 "AR* PIPE PRODUCTS HOUSTON CORPORATE 11011 FREE 1-800-999-30091 FAX 281-558-9000 www.starpipeproducts.com Page 2 STAR®PIPE PRODUCTS Joint Restraint Submittal Form PROJECT NAME. ENGJNEER. CONTRACTOR: SPEC. SECTION: <> a (D APPROVED AWWA MEMBER FEATURES CA6V'A;'NTAG&~~, 1 3600 contact, no pipe distortion or point loading Restrainers work with Push-On Pipe Bells. All restrainers are machined to exact tolerances. Rated pressures carry a 2:1 safety factor. Can be installed outside the trench, to ease installation Clamping Bolts: SAE J429 Grade 5 I IOOC on pipe be// Series 1100C is approved by Factory Mutual Research in sizes 4-6" for use on C900 PVC DR 18, for 150 PSI. Available in sizes 448' Gland: Ductile Iron per ASTM A536, Grade 65-45-12 GLAND FINISH OPTIONS (Please check one): flStandard: alkyd enamel coating fl Optional: StarbondTM TGIC polyester powder coating applied by an electrostatic spray process Optional: Other (specify) COUNTRY OF ORIGIN OPTION (Please check one): Import 100% Domestic' Domestic gland with import components' ('Please see Domestic Restraint potions Available on our website.) IB HARDWARE OPTIONS (Please check): fl Standard: 1-bolts are high strength low alloy steel manufactured in accordance with ANSI/AWWA Cii 1/A21.1 1-00 fl Optional: T-bolts and nuts alloy 55 304 per ASIM F593 Optional: T-bolts and nuts alloy SS 316 per ASIM F593 F Optional: T-bolts and nuts Fluoropolymer Star-Blue coated high strength low alloy steel manufactured in accordance with ANSI/AWWA C1 1/A21.11-00 STAR PIPE PRODUCTS HOUSTON CORPORATE ITOLL FREE 1-800-999-30091 FAX 281-558-9000 vww.starpipeproducts.com Page 1 ____C- j I RESTRAINER A RESTRAINER fl(RESTRAINING ROD T PVC PIPE 4"- 12 Sizes chel I ' ) ) T1iETh' .i'i'ii* PVC PIPE PVC PIPE NOM. WITH DUCTILE WITH STEEL PIPE O.D. A B C RESTRAINT BOLTS/ CLAMPING BOLTS APPROX SIZE IRON PIPE O.D. STYLE STYLE 1100S APPROX. MAX. RODS WI. (LBS) 1100C se Plet __________ O.D. O.D. QTY SIZE QTY Cksizes: SIZE 4 4.80 4.50 1.12 9.12 12.00 - 2 3/4 x17 4 5/8x3 1/2 16 6 6.90 6.63 1.15 11.12 13.00 2 3/4x17 4 5/8x31/2 20 8 9.05 8.63 1.47 14.75 15.00 2 3/4x 17 4 3/4x4 32 ] 10 11.10 10.75 1.38 16.82 16.00 4 3/4 x24 4 7/8x5 52 12 13.20 12.75 1.42 19.46 18.00 4 3/4 x 24 4 7/8 x 5 56 14 15.30 N/A 4.00 22.68 24.00 6 3/4 x 30 8 7/8 x 7 150 16 17.40 N/A 3.75 24.65 28.00 6 3/4 x 30 8 7/8 x 6 1/2 117 18 19.50 N/A 4.25 26.65 28.00 8 3/4 x 30 8 7/8 x 6 1/2 147 20 21.60 N/A 5.00 28.88 28.00 8 3/4x36 8 1 1/8x81/2 206 24 25.80 N/A 5.00 33.98 34.00 12 3/4 x36 8 1 1/8x81/2 265 30 32.00 N/A 7.00 42.48 38.00 12 1 x 48 12 1 1/8x6 492 El 36 38.30 N/A 9.00 49.10 38.00 14 1 x48 12 1 1/8x9 1/2 753 42 44.50 N/A 11.00 57.00 46.00 16 1 1/4x54 12 11/2 x 1 1916 48 50.80 1 N/A 1 11.00 63.88 46.00 16 1 1/4x54 12 1 1/2x10 2242 SERRATIONS B WASHER STANDARDIZED PRESSURE RATINGS" ANSI/AWWA ANSI/AWWA C900 C905 IPS OD ASTMD2241 CI OD CI OD DR 14 3 200 PSI DR 18 235 PSI SDR 17 250 PSI DR 18 150 PSI DR 21 200 PSI SDR21 200 PSI DR 25 } 100PSI DR 25 165 PSI 5DR26 160 PSI DR 32.5 125 PSI For ordinary water works with transient surges only. Ratings are for PVC pipes with SERIES 1000 Restrainer A - PVCPIPE -' 14- 48" Sizes SERRATIONS WASHER _C_ RESTRAINER RESTRAINING ROD - *4// dimensions in inches except where indicated 8' REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR' PIPE PRODUCTS HOUSTON CORPORATEITOLL FREE 1-800-999-30091 FAX 281-558-9000 www.starpipeproducts.com Page 2 MATERIAL SUBMITTAL DESCRIPTION: RW Gate Valves MANUFACTURER(s): AVK SPEC SECTION: COMMENTS: AMERICAN AVK RESILIENT SEATED DUCTILE IRON GATE VALVE 4513X 250 PSI, Tested to AWWA C509 I C515 (N RS) MJxFL Mechanical Joint by Flanged Ends to ANSI 1316.1 Class 125 -Valve Sizes 3" -16" Use: For water and neutral liquids to maximum 160°F. Tests: Hydraulic test to AWWA C509: Shell Test: 500 PSI Seat Test: 250 PSI Operating Torque Test Standard Materials: Body, Bonnet, Ductile iron ASTM A536 Gland Flange, (Wrench Nut-painted black for Wrench Nut open left, red for open right) Coating Electrostatically applied fusion- bonded epoxy-resin Meets or exceeds AWWA C550 Stem Standard: Stainless steel ASTM A582 Wedge Ductile iron ASTM A536 encapsulated with EPDM-rubber compound Wedge Nut, Thrust Collar Bronze Bonnet Bolts Stainless Steel - 304 sealed with hot melt Gland Bolts Stainless Steel - 304 Hexagon bolt Bonnet Gasket, ASTM D2000 Buna "N" nitrile Wiper Ring, rubber 0-Ring Stem Seals, 0-Ring Gland Seal Approvals:asip c®us® "UL/ULC Listed, 3-12" WAlER QUALITY *FM Approved, 3-12" NSF-61 (audited by UL), 3"- 16" * Approved at 250 PSI working pressure Optional Materials: Stem Option a): For UL, FM, ULC Low zinc bronze ASTM B763 Anti Friction Washers Polyamide Bonnet Bolts Option a): For UL, FM, ULC ASTM A164 zinc coated steel sealed with hot melt Option b): Stainless Steel - 316 sealed with hot melt Gland Bolts Option a): For UL, FM, ULC ASTM Al 64 zinc coated steel Hexagon bolt Option b): Stainless Steel -316 Hexagon bolt rN American AVK Company an ISO 9001-2000 registered company DS 5453X MJFL Subject to change without notice. (rev. 03108) -I AMERICAN AVK RESILIENT SEATED DUCTILE IRON GATE VALVE 45/3X 250 PSI, Tested to AWWA C509 I C515 (NRS) MJxFL Mechanical Joint by Flanged Ends to ANSI B16.1, Class 125 -Valve Sizes 3" - 16" Component List: Bonnet 227. Gland Flange Bolt 232. Lower Stem Seal 0-Ring Bonnet Gasket 228. Gland Flange 233. NRS Stem Body 229. Gland 0-Ring 234. Thrust Collar Wrench Nut 230. Upper Stem Seal 0-Rings 237. Wedge Wiper Ring 231. Stem Seal Bushing Ref No. Size D E F K H L M N T U Flange Turns to Weight Holes Open (lbs.) 45-080-3X 3" 7.69 4.96 4.08 6.00 12.09 9.0 2.50 0.75' 1.00' 0.88" 4 12 43 45-100-3X 4" 9.12" 6.02 4.90" 7.50' 13.50" 9.0' 2.50 0.75" 1.00" 1.00" 8 14 62 45-150-3X 6" 11.12" 8.12' 7.00" 9.50" 17.30 10.50' 2.50 0.88" 1.18" 1.06" 8 21 103 45-200-3X 8" 13.37" 10.27' 9.15" 11.75' 21.50' 11.50" 2.50 0.88" 1.24' 1.14" 8 26 155 45-250-3X 10' 15.69' 12.34" 11.20" 14.25° 24.75° 13.00° 2.50 1.00' 1.14" 1.22" 12 32 240 45-300-3X 12" 17.88" 14.44" 13.30" 17.00' 27.63" 14.00" 2.50 1.001, 1.22" 1.30" 12 38 337 45-350-3X 14" 20.31° 16.61" 15.50" 18.75' 35.75° 17.50° 3.50 1.13° 1.32" 1.40" 12 51 840 45-400-3X 16" 22.56" 18.64" 16.12" 21.25' 34.75° 17.00' 3.50 1.13' 1.34' 1.44" 16 51 820 DS S453X MJFL Subject to change without notice. (rev. 03108) MATERIAL SUBMITTAL DESCRIPTION: DI Fittings MANUFACTURER(s): Tyler Union SPEC SECTION: COMMENTS: MECHANICAL JOINT C153 DUCTILE IRON COMPACT FITTINGS Sizes 3-12" UL & 3-10" FM Listed TYLER UNION For Fire Main Equipment SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply) Mechanical loint watermain fittings with accessories, 2" through *64fl shall be manufactured from ductile iron in accordance with and meet all applicable terms and provisions of standards ANSI/AWWA C153/A21 .53 and ANSI/AWWA Cli 1/A21 .11. Ductile iron mechanical joint fittings 2' through 24" shall be rated for 350 PSI working pressure. Ductile iron 30' through 48" shall be rated for 250 psi working pressure. Flanged ductile iron fittings in 24(610mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special (annular ring or comparable) gaskets. All coated and lined fittings meet requirements of NSF-61, NSF-372, and Annex G. NOTE - EXCEPTIONS: Mechanical joint fittings with flanged branches are rated for water pressure of 250 PSI. NOTE - Wyes over 12" are not pressure rated. Contact manufacturer for rating in your application. NOTE -Fittings are cement lined and seal coated in accordance with ANSI/AWWA C104/A21.4. Fittings are available double cement-lined, bare, or epoxy coated upon request. Epoxy coating per ANSI/AWWA Cli 6 NOTE - Installation per AWWA C600 and AWWA C651 I NOMINAL JOINT DIMENSIONS IN INCHES BOLTS Size ADia. B CDia. DDia. FDia. JDia. K'Dia. K2 Dio. I M S T X Size No. 2 2.51 2.50 3,50 3.60 2.61 4.75 6.19 6.89 .58 .62 .36 .30 3/4 5/ex3 2 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 3/4 5/8x3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 318 3/4X3½ 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 /8 3/4X31/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 78 3/4x4 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 318 3/4X4 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 ¼ 3/4x4 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .55 .47 78 3/4x41/2 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .58 .50 78 3/4x4½ 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 ¼ 3/4x4½ 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 78 I/x4'/2 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 78 3/4x5 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 lYe 1x6 20 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1!/e 1x6 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.35 .82 1% 11/4x6½ 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 lYe 11/4x6½ 32 NOTE: 2 Inch MJ ASTM A536 ductile iron Compact fittings (2-22.5 bend, 2-45 bend, 2°-90 bend, 25d2' solid sleeve, 2'x2" tee, 4"x2" tee, and 4"x2" reducer) are available beginning 2012. Call Tyler Union for availability or additional product dimensions. *NOTE: Contact Tyler Union for 54-64 product information. NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks for the laying length of a specific fitting. 3 256772_uti1ity catalog.pdf 3 12/15/08 82418 AM DUCTILE IRON C1 10 FLANGED FITTINGS Sizes 3 thru 12 UL Listed for Fire Main Equipment TYLER UNION SAMPLE SPECIFICATION (Current ANSI/AWWA revisions apply) Flanged fittings, 2 through 48 shall be manufactured of ductile Iron in accordance with all applicable terms and provisions of standards ANSI/AWWA C110/A21.10. Flange surfaces shall be faced and drilled in accordance with ANSI Class 125, B16.1. All ductile iron Hanged fittings shall be rated for water pressure of 250 PSI. Flanged ductile-iron fittings in 24-in. (610 mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. NOTE: Fittings are cement lined and seal coated in accordance with ANSI/AWWA C104/A21.4. Fittings are also available prime coated, bare or epoxy coated. All coated fittings meet requirements of NSF-61, NSF-372, and Annex G. Interiors of fittings shall be lined and seal coated in accordance with ANSI/AWWA C104/A2 1.4. Cement mortar lining for ductile iron pipe and fittings for potable water unless otherwise specified. Installation of fittings shall be per AWWA C1 10. FLANGE DETAILS 0 00 T 0B.C. ow 0- lcJ NOTE: No flange joint material furnished. Nominal Dia. of Flange Pipe Size Flange Bolt Thickness Bolt Hole Number Bolt Dia. Inch O.D. Circle T Diameter of Bolts and Lengths 2 6 4.75 .62 .75 4 % x 21/4 3 7.5 6 .75 .75 4 ½ x 21/2 4 9 7.5 .94 .75 8 %x3 6 11 9.5 1.00 .875 8 3/4x3½ 8 13.5 11.75 1.12 .875 8 3/4 x3½ 10 16 14.25 1.19 1.00 12 12 19 17 1.25 1.00 12 7/a x4 14 21 18.75 1.38 1.125 12 1x4½ 16 23.5 21.25 1.44 1.125 16 1 x4½ 18 25 22.75 1.56 1.25 16 1Yex5 20 27.5 25 1.69 1.25 20 1'/ex 5 24 32 29.5 1.88 1.375 20 11/4 x 51h 30 38.75 36 2.12 1.375 28 1'/456½ 36 46 42.75 2.38 1.675 32 1½x7 42 53 49.50 2.62 1.625 36 11/2X7V2 48 59.50 56.00 2.75 1.625 44 11hx8 NOTE: Drilling templates are in multiples of four, so that fittings may be made to face in any quarter. Bolt holes shall straddle the center line. 30 256772_utility catalog.pdf 30 12/15/08 82426 AM Compact MJ Fittings ANSI/AWWA C153/A21.53 2" - 64" DUCTILE IRON MECHANICAL JOINT COMPACT FITTINGS GENERAL SPECIFICATIONS MATERIAL: Ductile Iron per ASTM A536 PRESSURE: 350 PSI rating for 2° - 24° sizes, 250 PSI rating for 30° - 48° sizes and 150 PSI rating for 54"- 64° sizes TESTING: In accordance with ANSI/AWWA C153/A2l.53 and UL requirements LAYING LENGTH: In accordance with ANSI/AWWA C1S3/A21.53 (fittings not listed in ANSI/AWWA have dimensions per Star design as noted in the catalog) DEFLECTION: 2-4=8° 1 6=7° 1 8-12=5° 1 14°-16'=3½° 1 18'-24"=3° 1 30'-48°2° WEIGHTS: Are in pounds, unless noted otherwise and do not include accessories, cement lining and coating FLANGES: Flanged ends on fittings match ANSI/AWWA Cl 15/A2 1.15 and ANSI B16.1 class 125 flanges CEMENT LINING: In accordance with ANSI/AWWA C104/A21.4 -- size 2° - 3° single thickness and sizes 4° - 64" double thickness COATING: Asphaltic seal coat inside and out in accordance with ANSI/AWWA C104/A21.4 and referenced in ANSI/AWWA C153/A21.53 GASKETS: SBRIn accordance with ANSI/AWWA Cli 1/A21.11 (see pg. 16) T-BOLTS/NUTS: Low alloy steel in accordance with ANSI/AWWA C I I I/A21.11 (see pg. 18) APPROVALS: 3"- 12° UL/ULC Listed 1 3° and greater are UL/NSF-61 1 3-16" FM APPROVED. Please consult factory for detail listing and approvals. DIMENSIONS: All dimensions are in inches unless noted otherwise. A. AWWA MEMBER $SI% <>® APPROVED WATER QUALITY NOM SIZE MECHANICAIJOINT A DIA. B DIMENSIONS C DIA. D NA. F NA. J DIA. K1 DIA. K2 DIA. L M S 0 X DIA. BOLTS SIZE NOV 2 2.50 2.50 3.39 3.50 2.61 4.75 6.19 6.25 0.58 0.62 0.36 28° 3/4 5Ax3 2 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 0.58 0.62 0.39 28° 3/4 5/sx3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 0.60 0.75 0.39 28° 7/s 3/4x3½ 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 0.63 0.88 0.43 28° 7/ 3/4x3½ 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 0.66 1.00 0.45 28° 7/ 3/4x3½ 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 0.70 1.00 0.47 28° 7/ 3/4x3V2 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 0.73 1.00 0.49 28° 7/ 1/4x3'/s 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.25 20.25 0.79 1.25 035 280 7/S 3/4 x4 10 16 17.40 3.50 1830 18.64 17.54 21.00 2230 22.50 0.85 1.31 0.58 28° 7/ 3/4 x4 12 18 19.50 330 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 0.68 28° 7/g 3/4 x4 12 20 21.60 330 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 0.69 28° 7/ 3/4 x4 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 0.75 280 /8 3/4x4½ 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 0.82 200 1½ 1x51/1 20 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 20° 1½ 1x5½ 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 200 13/s 1¼x6 28 . 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 20° IN 11/4 x6 32 54 60 (Fittings & Dimensions Available On Request) -s-- UCAT.12.01 REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS RI O HOUSTON CORPOIATE TOLL FREE I.00O.999.3c9 FAXISI.SSS-9550 w.0,,pipoprodoc,c,,,, Page 3 Flanged Fittings ANSI/AWWA C11O/A21.1O V - 64" DUCTILE IRON FLANGED FITTINGS GENERAL SPECIFICATIONS MATERIAL: Ductile iron per ASTM A536 PRESSURE: 250 PSI ratiing for 1'- 48" sizes and 150 PSI rating for 54"- 64" TESTING: In accordance with ANSI/AWWA C1IO/A21.I0, UL and FM requirements LAYING LENGTH: 2'- 48' sizes in accordance with ANSI/AWWA C1 10/A21.10 and ANSI 1316.1 and 54'- 64' sizes in accordance with ANSI/ AWWA C 153!A21.53 (fittings not listed in ANSI/AWWA have dimensions per Star design as noted in the catalog) WEIGHTS: Are in pounds, unless noted otherwise and do not include accessories, cement lining and coatings DRILLING: In accordance with ANSI/AWWA Cl 10/A2 1. 10, ANSI/AWWA C153/A21.53 and ANSI B 16.1 Class 125 Flanges CEMENT LINING: In accordance withANSI/AWWA C104/A21.4 -- sizes 1"- 3" single thickness and sizes 4"- 64" double thickness COATING: Asphaltic seal coat inside in accordance with ANSI/AWWA C104/A21.4 and prime coat outside APPROVALS: 2" - 12" Underwriters Laboratories and ULC Listed and Factory Mutual approved for 300 PSI rating. Please consult factory for detail listing and approvals. 2" and greater are UL/NSF-61. DIMENSIONS: All dimensions are in inches unless noted otherwise. IFLANGE DETAILS NOM. o D SIZE B C T BOLT HOLE DIA. BOLTS SIZE NO. 1 4.25 3.12 0.44 0.62 ½x2 4 1½ 5.00 3.88 0.56 0.62 ½x2 4 2 6.00 4.75 0.62 0.75 %x2¼ 4 21/2 7.00 5.50 0.69 0.75 5/sx21/2 4 3 7.50 6.00 0.75 0.75 5A x 2½ 4 4 9.00 7.50 0.94 0.75 5/sx3 8 5 10.00 8.50 0.94 0.88 1/4x3 8 6 11.00 9.50 1.00 0.88 1/4x3½ 8 8 13.50 11.75 1.12 0.88 3/4 x3½ 8 10 16.00 14.25 1.19 1.00 3/sx4 12 12 19.00 17.00 1.25 1.00 7/sx4 12 14 21.00 18.75 1.38 1.13 1 x41/2 12 16 23.50 21.25 1.44 1.13 1x4½ 16 18 25.00 22.75 1.56 1.25 1 1/8 x5 16 20 27.50 25.00 1.69 1.25 1 YsxS 20 24 32.00 29.50 1.88 1.38 1¼x5 1/2 20 30 38.75 36.00 2.12 1.38 1¼x6½ 28 36 46.00 42.75 2.38 1.63 1½x7 32 42 53.00 49.50 2.62 1.63 1½x7½ 36 48 59.50 56.00 2.75 1.63 1 ½x8 44 54 66.25 62.75 3.00 2.00 11/4 x 8½ 44 60 73.00 69.25 3.12 2.00 13/4 x9 52 64 1 80.00 1 76.00 1 3.38 1 2.00 1 13/4 x9 52 UCAT.I2.51 REGISTERED TRADEMARK OF STAR PIPE PRODUCES STAR PIPE PRODUCTS Page HOUSFONCORPOIATE ToLLFREEI-sso-999-3cC9 FAXZsI.SSs9550 A. <@> AWWA APPROVED MEMBER uW WATER (IUAUTY MATERIAL SUBMITTAL DESCRIPTION: DI Spools MANUFACTURER(s): Custom Pipe & Fabrication Inc. SPEC SECTION: COMMENTS: CUSTOM PIPE & PABRICATIOn IflC Date: 10-04-18 To: S&J Supply Jason Marano Re: Submittal This will certify that all Ductile Iron pipe spools fabricated by Custom Pipe and Coupling are made to conform to, ANSI/A WWA C115/A21.15, C151/A21.51, and C606 standards. Custom Pipe and Coupling is a member of the National Association of Pipe Fabricators. Custom Pipe & Coupling fabricates all Ductile Iron spools in Stanton, California and Phoenix, Arizona & Woodburn, Oregon. Sincerely, Michael T. Litty Custom Pipe & Coupling 10560 Fern Avenue Stanton, Ca. 90680 / 714-761-8801 I 714-761-3417 Material used in accordance with A WWA & ANSI standards Pipe Ductile Iron per AWWA/ANSI C151 /A21.5 & AWWA /ANSI C150/A21.50, class 53 and NSF 61 compliant. Pipe will be thickness class 54. Flange Per A WWA Lining Double Cement per AWWA C104 Coating Bit coated 10560 Fern Avenue Stanton, Ca. 90680 / 714-761-8801 I 714-761-3417 MATERIAL SUBMITTAL DESCRIPTION: Bury & Extensions MANUFACTURER(s): South Bay Foundry SPEC SECTION: COMMENTS: South BEIg Faiundrg J-1 WWW.SOUTHBAYFOUNDRY.COM PHONE: (619) 956-2780 FAX: (619) 956-2788 WATER WORKS - 2 BURY EL MECHANICAL JOINT DUCTILE IRON DI 350 SECTION B-B 16 X "A"WT (LBS)I 6 X 161 76 6X24 98 6X30 6X36 105 117 6X42 134 6X48 151 170 6X54 SECTION MACHINED SURFACE MARKED WITH CO. OF ORIGIN AND "SBF'T GENERAL INFORMATION I APPROVED *MATERIAL IS MADE IN ACCORDANCE WITH AWWA STANDARDS C-i 53 *CONTAINS 1/811 THICK CEMENT LINING UNLESS OTHERWISE REQUIRED *CEMENT LINING CONFORMS TO AWWA SPFCIFICATION ç-104 *FLANGES AVAILABLE DRILLED: 6 HOLE, 7/81; 6 HOLE, 3/418 HOLE, 7/8"; OTHER AS REQUIRED *UL APPROVED TITLE: AGENCY: DATE: 6X16 82 LB 6X18 88 LB 6X20 94 LB 6X22 101 LB 6X24 106 LB 6X26 110 LB 6X28 118 LB 6X30 124 LB 6X32 132 LB 6X36 142 LB S ECTI ON \ _AA, /EED 61 0 H V/ A r-IBREAK-OFF GROC 7/167 MACHINED SURFACE MARKED WITH CO. (t (ThDI(IkI AND South Bag Rmundrg WWW.SOUTHBAYFOUNDRY.COM PHONE: (619) 956-2780 FAX: (619) 956-2788 WATER WORKS-2 FIRE HYDRANT EXTENSION CAST IRON rs1 6X4 45 LB 6 X 6 50 LB 6 X 8 58 LB 6X10 64 LB 6X12 70 LB GENERAL INFORMATION *MATERIALS MADE IN ACCORDANCE WITH AWWA STANDARDS Cl 10 *CEMENT LINED UNLESS OTHERWISE REQUIRED *CEMENT LINING CONFORMS TO AWWA SPECIFICATION 104 *FLANGES AVAILABLE DRILLED: 6 HOLE, 7/81; 6 HOLE, 3/4"; 8 HOLE, 7/8"; OTHER AS REQUIRED *UL LISTED APPROVED DY: TITLE: AGENCY: DATE: MATERIAL SUBMITTAL DESCRIPTION: Fire Hydrant MANUFACTURER(s): Clow Valve SPEC SECTION: COMMENTS: 2 A 12/29/04 00001 2000 SERIES WET BARREL HYDRANT MATERIAL LIST CLOW VALVE COMPANY MODELS 2010, 2050, 2060, 2065 I ®®-X) (;) A A / 15 O 14 13 12 11 10 V SECTION A-A B CLOW BEIkc$Ø PfraDc 2004 14 13 12 11 10 SECTION B-B ITEM DESCRIPTION MATERIAL ASTM SPEC. I Outlet Nozzle Cap Gray Iron or Plastic ASTM A126 Cl B / N/A 2 Outlet Nozzle Gasket(Gray Iron Only) Rubber Buna N 3 Hose Outlet Nozzle or Brass _Outlet _Nozzle ASTM B584 C83600 Pumper 4 Nozzle 0-Ring Rubber Buna N 5 Set Screw Steel N/A 6 Stem Brass ASTM B763 C99500 7 Body Brass ASTM B584 C83600 8 Stuffing Box 0-Ring Rubber Buna N 9 Stuffing Box Brass ASTM B584 C83600 10 Stuffing Box 0-Ring Rubber BunaN 11 Stem Nut Brass ASTM B584 C83600 12 Valve Carrier Brass ASTM B763 C99500 13 Valve Washer Rubber Urethane 14 Retaining Nut Brass ASTM B763 C99500 15 Chain Assembly Steel Zinc Plated 21 5/8" 14 1/8" 26 3/4" MODEL 2 2065 2000-OS A 12/29/04 2000 SERIES WET BARREL HYDRANT GENERAL DIMENSIONS CLOW VALVE COMPANY MODELS 2060 & 2065 1 I..' I IIIL1 JI '..J3IJI I RI IIIL1IIL'I I led per customer specifications w. 0 111/4" - MATERIAL SUBMITTAL DESCRIPTION: DCDA MANUFACTURER(s): Apollo SPEC SECTION: COMMENTS: 1 A nn. /-tpow Valves SUBMITTAL SH EET LEAD F REEF - Model DCDALF 4A - Model DCDA2LF 4A Double Check Detector Assembly Job Name: Job Location: Engineer: Contractor: Tag: P0 Number: Representative: Wholesale Distributor: OCbFFrEE Q II EK Cf =WARRANTY SPECIFICATIONS The 21/2"- 12" Double Check Detector Assembly shall bean Apollo Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo factory warranty. The TriForceTM center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by SS snap-in retainers (2 ½" - 6") or SS studs & nuts (8"— 12"). Access to the check valves shall be by an Apollo* quick-connect SS coupling (2 1/2"— 6") or grooved couplings (8"— 12"). The bodies shall be domestic SS in 2 1/2"- 8" sizes and FDA epoxy-coated ductile iron in 10"& 12" sizes. The assembly consists of a mainline double check valve with a Type 2 bypass consisting of a lead free* single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free* double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo lead free* domestic ball valve test cocks shall have SS handles.The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards. FEATURES Domestic Stainless steel body: 2½" —8" FDA epoxy-coated ductile iron body: 10"& 12" Easy maintenance - no special tools required Snap-in check retainers: 2 ½" —6" Bolted-in checks: 8"— 12" Low pressure loss as documented by an independent laboratory Center-stem guided TriForcelM check valves Approved for horizontal (21/2"-12") and vertical flow up(2½°-8°) US Patent Nos. 6,443,184; 7,025,085; 7,533,699 Made in the USA (D option) PERFORMANCE RATING Maximum Working Pressure 175 psi Temperature Range 33°F - 140° F Hydrostatic Test Pressure 350 psi APPROVALS Sizes 21/2"— 12": ASSE 1048°, CSA 864.5, FM, UL°, cUL° °ASSE, UL, and cUL installations must include indicating-type shut-off valves NSF 372(2½"-12") Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California (Model DCDALF 4A, 2-1/2°- 8") FACTORY CODE i:i XX BY-PASS SUB-ASSEMBLY OPTIONS SIZE (IN.) METER OPTION SHUT-OFF VALVES (Inlet X Outlet) OPTIONS 4ALF = Lead Free 0 0 = Type 1w! 1/2" Double Check 0 9=2-1/2 El C=Cubicfeet/min 0 1 = Less Shut-off Valves El D = Domestic El 2= Type 2w/1/2"singleCheck El 0=3 El E=Gallons/min El 3 = OS&Y Fig x OS&Y Fig El Ri = Retrofit* (Standard) El A=4 El G = Less meter El 4 = OS&Y Fig x Monitored (Mon.) Butterfly Vie Grv° 0 R2 = Retrofit* El 3 = Type 1w/bypass on left* El C=6 El 6 = OS&Y Fig x Post indicator Fig El R3 = Retrofit* 0 4 = Type 2w/bypass on left* El E=8 0 7 = OS&Y Fig x OS&Y Gry *Custom length El 6=10 El 8 = OS&Y Gry x OS&Y Gry retrofit orders must El Fi=12 El 9 = Mon. ButterflyVlv Gry x Mon. ButterflyVlvGrv° be accompanied El 10= OS&Y Fig x Post Indicator Gry with signed form El 13 = Post Indicator Fig x Mon. Butterfly VIe Grvt #OFBFRETRO El 14 = Post Indicator Fig x Post Indicator Fig with exact length El 16 = Mon Butterfly VIe Gry x Post Indicator Fig' required 0 17 = Post Indicator Fig x OS&Y Gry 0 18 = OS&Y Gry x Post Indicator Gry El 19 = Mon. Butterfly VIv Gry x Post indicator Grvt El 20 = Post Indicator Fig x OS&Y Fig * Orientation of bypass looking downstream. El 21 = PostlndicatorGrvx0S&YGry Standard is right hand side. Left hand is on opposite side El 22 = Post Indicator Gry x Mon. Butterfly VIe Grvt t Butterfly valves not available in 12'size. El 23 = Mon. Butterfly VIe Grvx OS&Y Fig Apollo Valves, Manufactured by Conbraco Industries, Inc. * LEAD FREE: The wetted surfaces of this product shall contain no more than 0.25% lead 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA by weighted average. NSF 372 ANSI 3rd party approved and listed. www.apoIlovalves.com 1 (704) 841-6000 This specification is provided forreference only. Conbraco Industries Inc. reserves the rightto change any portion of this specification without notice and witho Ut incurring obligation to make such changes to (onbraco products previously orsubsequently sold. Please visit our weboite @ www.apollovalves.com for the most current inform ation. AALBERTS INDUSTRIES 551328 0 06/16 Page 1 of3 TYPE 1 BYPASS A 1A flhl# AO4!Iff Valves SUBMITTAL S H EIE7 LEAD LIEE - Model DCDALF 4A - Model DCDA2LF 4A Double Check Detector Assembly E (MAX) E?::IcEEiI \ Internal component F - } - removal space / requirements TYPE 2 BYPASS DIMENSIONS Nominal dimensions are shown. Allowances must be made for ti erances (± 1/8" (3 mm) per joint) DIMENSIONS 2-1/2" 65mm 3" 80mm 4" 100mm 6" 150mm 8" 200mm 10" - 250mm 12" 300mm A (Butterfly Valves) 28 ± 711 ± 28-1/2 ± 724k 33-1/4k 845k 38-7/8± 987k 46-3/8k 1178k 6-1I4 ± 1429k N/A N/A A (Gate Valves) 31± 787 ± 32 ± 8131 38± 965 ± 45-7/8 ± 1165 ± 53-3/8± 1356k 2-1/4 ± 1581 ± 65-1/2 ± 1664± B (Less Shut-off Valves) 15-7/8k 403 ± 15-7/8k 403 ± 19-5I8 498k 24-1/2± 622 30 ± 762 ± 36 ± 914k 37± 940k ((Butterfly Valves) 8 203 8.3/8 213 9-1/8 233 10-1/8 257 12 306 13-3/8 340 N/A N/A C(NRS/P1 Gate Valves) 11-3/4 298 13 330 14 356 17-3/4 451 21 573 24-1/2 622 30 762 ((OS&YOpen) 18 457 20 508 21 533 29-1/2 749 37 940 45 1143 53-1/8 1348 D (Centerline to bottom) 3-7/8 98 3-7/8 98 4-5/8 117 6 152 8-1/8 206 11-3/4 298 12 305 E(Width Max) 17 432 17 432 17 432 20 508 21-1/2 546 26-1/2 673 26-1/2 673 F (Check Removal Clearance) 4-3/4 121 4-3/4 121 6-1/2 165 7-1/2 191 7-1/2 191 10 254 10 254 Test Cocks (NPT) 1/2" 13 1/2" 13 1/2" 20 3/4' 20 3/4" 20 3/4" 20 3/4" 20 WEIGHTS lb. kg lb. kg lb. kg lb. kg lb. kg lb. kg lb. kg Net Wt. (Less Shut-of) 37 17 38 17 54 25 90 41 223 101 722 327 825 374 Net Wt. (w/ Butterfly Valves) 64 29 68 31 98 45 158 72 354 161 940 426 N/A N/A Net Wt. (w/0S&Y Gate Valves) 133 60 159 72 209 95 339 154 700 318 1608 729 2017 915 Notes: I Nominal dimensions are shown. Allowances must be made for manufacturers' tolerances (1/8" per joint). Internal body connections are grooved on 2 ½" - 10" sizes. Internal body connections are flanged on 12"size. Apollo Valves, Manufactured by Conbraco Industries, Inc. * LEAD FREE: The wetted surfaces of this product shall contain no more than 0.25916 lead 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA by weighted average. NSF 372 ANSI 3rd party approved and listed. www.apollovalves.com 1 (704) 841-6000 This specification is provided for reference only. (enbroco Industries Inc. reserves thenghtto chenge any portion of this specification withautnoticeand without incurring obligation to make such changes to Conbruco products previously orsubsequentlysold. Please visitourwebsiteat www.apolluvaIves.com for the most current information. AALBERTS INDUSTRIES SS1328©06/16 Page 2 of 3 FLOW CURVES 0 Meter Rated Flow 'Apo&'vaives SUBMITTAL SHEE7 LEAD LFEE - Model DCDALF 4A - Model DCDA2LF 4A Double Check Detector Assembly Part Name Material Body (21/2"— 8") 304 Stainless Steel Body (10"& 12") FDA Epoxy Coated Ductile Iron Covers (2½"— 6") Glass-filled PPO/Stainless Steel Cover (8") 304 Stainless Steel Covers (10"& 12") FDA Epoxy Coated Ductile Iron Check Valves (2½"— 12") Glass-filled PPO/Bronze (C89836 Lead-Free8)/SS Bypass Valves Bronze (C89836 lead_Free*) Springs Stainless Steel Seat Discs Chioramine-resistant Silicone STANDARD MATERIALS LIST 20 DCDALF4A ----- -----.--._.- —2.5 —3' —4' S METERRATEDFLOW HO ir 14 12 16 10 O100 280 300 400 Flow,ate (gpm) Soo 600 7® is DCDALF4A —6' —8' METER RATED FLOW 14 13 12 11 10 0 200 400 600 800 1000 1200 1400 Flowrate (gpm) 1600 1800 2000 2200 2400 DCDALF4A —10" —12' • METER RATED FLOW 22 21 20 28 16 is 14 13 12 11 -- Ole 10 12 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 Flowrate(gpm) Notes: Flow curves directly reflect data collected by an independent laboratory. Flow curves shown were recorded with gate shut-off valves. Contact factory for more information. Apollo Valves, Manufactured by Conbraco Industries, Inc. All data points are based onASSE increasing flowdata, from zero GPM to rated flow (opening curve). 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA For high flow rates/pressure loss information -contact factory. www.apollovalves.com 1 (704) 841-6000 This specification is pro vided for referen ce only. Conbraco!ndustries Inc. reserves the right to change any portion of this specification witho Ut notice and witho of incurring obligation to make such changes to Conbra co products previously orsubsequentlysold. Pleasevisitourweboite@www.apollovalves.com for the most current information. AALBERTS INDUSTRIES 551328 © 06/16 Page 3 of 3 MATERIAL SUBMITTAL DESCRIPTION: OS&Y Tamper Switch MANUFACTURER(s): Potter SPEC SECTION: COMMENTS: OSYSU Series (OPOTTER Outside Screw and Yoke Vqlv The Symbol of Protection Supervisory Switch Features NEMA 4X* (IP 65) and 6P (IP 67) *Enclosure is 4X For additional corrosion protection of mounting hardware, use model OSYSU-2 CR1-I -40° to 140° (-40°C to 60°C) operating temperature range Visual switch indicators Two conduit entrances Adjustable length trip rod Accomodates up to 12AWG wire Three position switch detects tampering and valve closure Knurled mounting bracket prevents slipping Fine adjustment feature for fast, easy installation RoHS compliant One or two SPDT contact models (-1,-2) Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. SIGNALING c®us<8>(E LISTED APPROVED Important: This document contains important information on the installation and operation of OS&Y valve supervisory switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS&Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as Y2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device. Testing The operation of the OSYSU and its associated protective monitoring system shall be inspected, tested, and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Jurisdiction (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve wheel towards the closed position. The OSYSU shall operate within the first two revolutions of the wheel. Fully close the valve and ensure that the OSYSU does not restore. Fully open the valve and ensure that the OSYSU restores to normal only when the valve is fully opened. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Technical Specifications Dimensions See Fig 8 Weight 1.6 lbs (0,73 kg) Cover: Die Cast Finish: Red Powder Coat Enclosure Base: Die Cast Finish: Black Powder Coat All parts have corrosion resistant finishes Tamper Resistant Screws Cover Tamper Optional Cover Tamper Switch Available OSYSU-1: One Set of SPDT (Form C) OSYSU-2: Two Sets of SPDT (Form C) Contact Ratings 10.0 Amps at 125/250 VAC 2.0 Amps at 30VDC Resistive 10 mAmps minimum at 24 VDC -40° F to 140°F (-40°C to 60°C) Environmental NEMA 4X (IP 65) and NEMA 6P (IP 67) Enclosure Limitations (Use suitably rated conduit and connector) Indoor or Outdoor Use (See OSYSU-EX Bulletin 5400705 for Hazardous locations) Conduit Two Knockouts for 1/2" conduit provided Entrances (See Notice on Page 6 and Fig. 9 on Page 5) Service Use NFPA 13, 13D, 13R, 72 Specifications subject to change without notice Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 5401525- REV E • 8/I5 PAGE iOF6 OSYSU Series @POTTFR Outside Screw an4 Yoke Vqlvç The Symbol of Protection Supervisory Switch Theory of Operation The OSYSU is a 3 position switch. The center position is the normal installation position. Normal is when the switch is installed on the OS&Y valve, the valve is fully open and the trip rod of the OSYSU is in the groove of the valve stem. Closing the valve causes the trip rod to ride up out of the groove and activates the switches. Removing the OSYSU from the valve causes the spring to pull the trip rod in the other direction and activates the switches. Visual Switch Status Indication There are 3 visual indicators to determine the status of the switches. Fig 1; the actuator button of the micro switches are on the raised section of the switch actuator. Fig 2; the trip rod is perpendicular to the base and lined up with the alignment mark on the mounting bracket. Fig 3; the white visual indicator is visible through the window on the back of the switch actuator. A final test is to meter the contacts marked COM and N.O. to ensure they are an open circuit when the valve is open and that they close and have continuity within 2 revolutions of turning the valve handwheel towards the closed position and the contacts remain closed as the valve is completely closed and until the valve is completely opened when the trip rod drops back into the groove in the valve stem. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV E • 8/15 PAGE 2OF6 OSYSU Series @POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Fig Small Valve Installation - 1/2" Through 2 1/2" Sizes uu 21AE, M'' MR i _2071117M", _11 Slotted mounting holes and micro-adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Small Valve Installation make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. NOTE: If the valve stem is pre-grooved at 1/8" minimum depth; proceed to step 7. Remove and discard °E' ring and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 6 if possible to avoid creating a pinch point between the wheel and the OSYSU. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 10). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. Utilizing a 3/16" or 1/4" diameter straight file, file a 1/8" minimum depth groove centered on the mark on the valve stem. Deburr and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16" can Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 6, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2 , to aid in initially locating the OSYSU. & Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. Tighten the adjustment screws and all mounting hardware securely (20 in-lbs minimum). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 5401525. REV E • 8/15 PAGE 3OF6 OSYSU Series @POTTER Outside Screw and Yoke Vqlv The Symbol of Protection Supervisory Switch Fig 7 Large Valve Installation - 3" Through 12" Sizes rr J ' 10 ' Slotted mounting holes and micro- adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Large Valve Installation NOTE: If the valve stem is pre-grooved at 1/8" minimum depth; proceed to step 6. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far from the valve gland as possible so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 7 if possible to avoid creating a pinch point between the wheel and the OSYSU. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 10). Reinstall trip rod and repeat Step 3 procedure. Mark the valve stem at the center of the trip rod. Remove the OSYSU. Utilizing a 3/8" or Y2" diameter straight file, file a 1/8" minimum depth groove centered on the mark on the valve stem. Debun and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16" can make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 7, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2 , to aid in initially locating the OSYSU. Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. Tighten the adjustment screws and mounting hardware securely (minimum 20 in-Ibs). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV E • 8/15 PAGE 4OF6 [77.471 -I I 2.25 (57.13] I Knockout Removal Fig 9 To remove knockouts: Place screwdriver at inside edge of knockouts, not in ved the center. NOTE: Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty (2)o.886 Knockouts For 1/, Electrical Condui Connections Ground S l/4"-201 Hardwai Clamp Bar OSYSU Series (DPOTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Dimensions Fig 8 [144.42 o //0 F 3,67 [9326 1 Rod fully extended C. Rod retracted and 1.17 breakaway section removed 129. 721 Cover Tamper Switch 6.19 [197.23] 4.00 1101,601 3,20 9116 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV E • 8/15 PAGE 5OF6 OSYSU Series (J)POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Breaking Excessive Rod Length Fig 10 Switch Terminal Connections Clamping Plate Terminal Fig 11 I àWARNING I An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8 of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. All conduit and connectors selected for the installation of this product shall be suitable for the environment for which it is to be used and shall be installed to the manufacturer's installation instructions. For NEMA 4, 4X, 6, 6P installations, the cover screws are recommended to be tightened to 15 in- lbs minimum and the trip rod locking screw tightened to 5 in-lbs minimum to properly seal the enclosure. Typical Electrical Connections Fig 12 EOLR CMNC N NONCCOM Ordering Information Model Description Stock No. OSYSU-1 Outside Screw & Yoke 1010102 Supervisory Switch (Single switch) OSYSU-2 Outside Screw & Yoke 1010202 Supervisory Switch (Double switch) OSYSU-2 Outside Screw & Yoke Supervisory 1010210 CRH Switch (Double Switch). Corrosion resistant hardware of 316 stainless steel & nickel plated to ASTM B377 Type V Brackets Cover Screw 5490424 Hex Key for Cover Screws and 5250062 Installation Adjustments Optional Cover Tamper Switch Kit 0090200 Engineering Specifications: OS&Y Valves UL, CUL Listed / FM Approved and CE Marked valve supervisory switches shall be furnished and installed on all OS&Y type valves that can be used to shut off the flow of water to any portion of the fire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The supervisory switch shall be NEMA 4X and 6P rated and capable of being mounted in any position indoors or out and be completely submerged without allowing water to enter the enclosure.. The enclosure shall be held captive by tamper resistant screws. The device shall contain two Y2" conduit entrances and one or two Single Pole Double Throw (SPDT) switches. There shall be a visual indicator to display the status of the switches. To aid in installation, it shall be possible to make fine adjustments to the position of the switch on the valve without loosening the mounting bracket from the valve. The device shall contain an adjustable length trip rod and roller, the trip rod shall be held captive by a set screw accessible upon removal of the cover. The switch contacts shall be rated at bA, 125/250VAC and 2A, 30VDC. OS&Y Valve supervisory switch shall be model OSYSU-1 for the single switch model and OSYSU-2 for the two switch model manufactured by Potter Electric Signal Company LLC Supervisory switches have a normal service life of 10-15 years. However, the service life may be significantly reduced by local environmental conditions. TO FIRE ALARM PANEL Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 150 900 1:2008 1 DESIGNING, MANUFACTURING, &DISTRIBUTING QUALITY SYSTEMS 5401525 - REV E • 8/15 PAGE 6 OF 6 MATERIAL SUBMITTAL DESCRIPTION: Pipe Supports MANUFACTURER(s): Pipeline Products SPEC SECTION: COMMENTS: 1200 Del HOLES TO MATCH FLANGE, SEE NOTE 3—, SADDLE TOP GUSSETS, FLANGE SEE NOTE 2 TOP U-BOLT TOP Th PIPELINE PRODUCTS RECIEVER WITH 1/2" SET SCREW, TO FIT OVER RISER NOTES: SIZE "A" SCH. 40 THREADED PIPE RISER THREADED ADJUSTER WITH 1/2" SETSCREW Ei _L__ L_1_ SIZE "B" SCH. 40 STEEL PIPE, FIELD TRIM TO SIZE, SEE NOTE 4 TOPS AND BASES ARE H.D. GALVANIZED. ADJUSTER AND RISER ARE ZINC PLATED. SADDLE GUSSETS ON 8" AND LARGER SIZES. FLANGE MOUNT SIZES 14" AND LARGER UTILIZE 4 FLANGE BOLT HOLES. STANDARD BASES ARE 30" TALL, OTHER LENGTHS OR CUSTOM LENGTHS AVAILABLE. L - BASE PLATE, SEE CHART FOR DIMENSIONS STANDARD ADJUSTABLE PIPE SUPPORTS SUPPORT TO FIT SUPPORT DIMENSIONS PART NUMBERS STEEL PIPE D.I. PIPE MAX PIPE O.D. BASE PLATE SIZE BOLT HOLE DIA. A B SADDLE TOP U-BOLTTOP FLANGE TOP 2 1/211 - 311 3/8 x 81/211 SQ. 9/1611 11/2" 21/211 PS-250-025S-30-HDG PS-250-025U-30-HDG PS-250-025F-30-HDG 3" - 3 1/2" 3/8 x 8 1/2' SQ. 9/16' 11/2" 21/2" PS-250-03S-30-HDG PS-250-03U-30-HDG PS-250-03F-30-HDG 31/2" 3" 41/8" 3/8 x 81/211 SQ. 9/16" 11/2" 21/2" PS-250-035S-30-HDG PS-250-035U-30-HDG PS-250-035F-30-HDG 411 4 47/8" 3/8x 12" SQ. 13/16" 21/2" 3" PS-300-045-30-HDG PS-300-04U-30-HDG PS-300-04F-30-HDG 5 5/8" 3/8 x 12" SQ. 13/16" 21/2" 3" PS-300-05S-30-HDG PS-300-05U-30-HDG PS-300-05F-30-HDG 6" 3/8x 12" SQ. 13/16" 21/2" 3" PS-300-06S-30-HDG PS-300-06U-30-HDG PS-300-06F-30-HDG 8" 91/8" 3/8 x 12" SQ. 13/16" 21/2" 3" PS-300-08S-30-HDG PS-300-08U-30-HDG PS-300-08F-30-HDG 10" 10" 111/8" 3/8 x 12" SQ. 13/16" 21/2" 3" PS-300-10S-30-HDG PS-300-10U-30-HDG PS-300-10E-30-HDG 12" 12" 13 1/2" 3/8 x 12" SQ. 13/16" 2 1/2" 3" PS-300-12S-30-HDG PS-300-12U-30-HDG PS-300-12F-30-HDG 14" 14" 1/2 x 13 1/2" SQ. 15/16" 3" 4" PS-400-14S-30-HDG I PS-400-14U-30-HDG PS-400-14F-30-HDG 16" 14" 16" 1/2 x 13 1/2" SQ. 15/16" 3" 4" PS-400-16S-30-HDG PS-400-16U-30-HDG PS-400-16F-30-HDG 18" 16" 18" 1/2 x 18" SQ. 11/81, 4" 6" PS-600-18S-30-HDG PS-600-18U-30-HDG PS-600-18F-30-HDG 20" 18" 20" 1/2 x 18" SQ. 11/8" 4" 6" PS-600-20S-30-HDG PS-600-20U-30-HDG PS-600.20E-30-HDG 22" 20" 22" 1/2 x 18" SQ. 11/8" 4" 6" PS-600-22S-30-HDG PS-600-22U-30-HDG PS-600-22F-30-HDG 24" - 24" 1/2 x 18" SQ. 11/8" 4" 6" PS-600-24S-30-HDG PS-600-24U-30-HDG PS-600-24F-30-HDG 26" 24" 26" 1/2x 18" SQ. 11/8" 4" 6" PS-600-265-30-HDG PS-600-26U-30-HDG PS-600-26F-30-HDG 30" . 30" 1/2 x 18" SQ. 11/8" 4" 6" P5-600-305-30-HOG PS-600-30U-30-HDG PS-600-30E-30-HDG 32" 30" 32" 1/2 x 18" SQ. 11/8" 4" 6" PS-600-325-30-HOG PS-600-32U-30-HDG PS-600-32F-30-HDG 36" - 36" 1/2x 18" SQ. 11/8" 4" 6" PS-600-365-30-HDG PS-600-36U-30-HDG PS-600-36F-30-HDG TOPS STOCKED UP TO 24!'- LARGER SIZES OR CUSTOM SIZES AVAILABLE SPECIAL ORDER DO NOT SCALE DRAWING STANDARD ADJUSTABLE PIPE SUPPORTS IDRAWN: HUELSMAN I REV: A DIMENSIONS ARE IN INCIIES (OLD PSG SERIES PIPE SUPPORTS) CALE: 1:6 I SHEET I OF 1 W:\Archive\Pipeline ProductsPipe Supports\Standard Supports\NEW PSG SERIESINEW PSG COMPLETE 304 AND 316 S.S. SUPPORTS ALSO AVAILABLE. III MATERIAL SUBMITTAL DESCRIPTION: Wafer Check MANUFACTURER(s): United Brass SPEC SECTION: COMMENTS: MATERIAL LIST NO. DESCRIPTION MATERIAL 1 Body Ductile Iron 2 Seat Ring Assembly Bronze 3 Screw Stainless Steel 4 Seat Ring 0-Ring Buna-N 5 Face 0-Ring Buna-N 6 Pipe Plug Steel Size A B C D Ship Wt. Qty. Per 4" 4.25 4.03 6.86 3.00 15.0 1 6" 3.75 6.06 8.50 4.50 19.0 1 8" 3.75 7.98 11.00 6.00 29.0 1 FRICTION LOSS FLOW GPM UNITED BRASS WORKS, INC. 714 S. Main St., Randleman, NC 27317 UKAS Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com Registered Model 90 Wafer Check Valve C®USUL Listed • FM Approved* *As antiwater hammer check valve for fire pump service only! 250 WOG @ 1801 Max 100% Pressure Tested Approved by New York City Board of Standards & Appeals under Calendar No. 157-84-SA. The 4" size is provided with '/2" pipe plug in drain port as standard configuration. *Contains Lead. Not Intended for Use in Potable Water Systems* S&i SUPPLY MATERIAL SUBMITTAL DESCRIPTION: FDC MANUFACTURER(s): Brecco SPEC SECTION: COMMENTS: Style Thread Item 411 NPT x 21/2" x 21/2" NST 350-175-02651 4" NPT x 3" x 3" NST 350-175-02660 6" NPT x 21/2" x 21/2" NST 350-175-02784 6" NPT x 3" x 3" NST 350-175-04380 4 'ki I Will FDCs Brecco FDCs are UL Listed and FM Approved in accordance with NFPA. Each FDC is of solid brass construction and single clapper design. ** Thread Item NST 350-175-02420 NST Chrome 350-175-02440 PHX/PIT 350-175-02460 TEMPE 350-175-02480 NYCC 350-175-02500 NST Brass 350-175-02540 NST Chrome 350-175-02560 NPT Pol. Brass 350-175-02565 PHX/PIT 350-175-02620 TEMPE 350-175-02640 NYCC 350-175-02580 NYFD 350-175-02600 Style Thread Item 4" NPT x 21/2" x 21/2" NST 350-175-02650 4" NPT x 21/2" x 21/2" NST 350-175-02645 4" NPT x 3" x 3" NST 350-175-02720 6" NPT X 21/2" X 21/2" NST 350-175-02785 6" NPT x 3" x 3" NST 350-175-04385 Brecco FDCs are UL Listed and FM Approved in accordance with NFPA. Each FDC is made of solid brass construction and single clapper design. ** Thread Finish ltem# Brecco FDCs are UL Listed and FM Approved in accordance with NFPA. Each FDC is made of solid brass construction and double clapper design. ** Brecco FDCs are UL Listed and FM Approved in accordance with NFPA. Each FDC is made of solid brass construction and double clapper design. 4" x 21/2" x 21/2" ** çTi1 Used as a flush mount double clapper Fire Deportment Connection. The double clapper design ensures water supply from supplementary sources, connected to either one or two servicing hoses. The Auxiliary Inlet Connection allows in excess of 500 G.P.M. supplementary water supply for fire protection system. UL Listed FM Approved. ** Style Thread Item 4" GRV x 21/2" x 21/2" NST 350-175-03380 4" Grooved x 3" x 3" NST 350-175-02705 4" NPT x 3" x 3" NST 350-175-02680 4" GRV X 21/2" X 21/2" NST 350-175-02700 6" GRV x 3"x 3" NST 350-175-02745 6" NPT x 3"x 3" NST 350-175-04390 * * Other thread types are available, but not listed. Please call for the specific thread you need. f 05