Loading...
HomeMy WebLinkAbout1610 FAIRLEAD AVE; ; FA150048; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA150048 Job Address: 1610 FAIRLEAD AV Permit Type: FALARM Parcel No: Lot #: 0 Status: ISSUED Applied 7/30/2015 Approved: 7/31/2015 Reference No.: Issued: 7/31/2015 PC #: Inspector: Project Title: VOSCANA HOA - GSM CONVERSION REPLACE 8 FACU WITH NEW PANEL TO ACCOMODATE NEW GSM COMMUNICATION. Applicant: Owner: BAY ALARM COMPANY 4883 RONSON CT SUTE C SAN DIEGO, CA 92111 714-719-9334 Fees ($) Add'I Fees ($) Total ($) Balance ($) 868 _ 0 868 SAY 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 LARM _ Contractor License # 880138 I I PROTECTED PREMISE Voscana HOA • 1610, 1613, 1636, 1660, 1684, 1718, 1746, 1752 • Fairfield Ave. Carlsbad, Ca 92011 I H. MONITORING COMPANY I Bay Alarm Company 60 Berry Drive I Pacheco, CA 94553 - 800-470-1000 I . California Alarm Operating License Number: ACO28 I ifi. EQUIPMENT SUPPLIER & INSTALLER 1 8205 Ronson Road, Suite F San Diego, CA 921111(800)470-1000 Contractor License # 880138 I I I APPROVED AS SUBMITTED I cJ E DEPARTMENT I I DF-52416:13 • A3-20 y Honeywell C-5—HUFF-0 6ffffu—nicatersi, I I • I I iii• I. - MS-5UD.3/MS-I0UD-7(E) I Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel I The MS-51JID-3 is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These control pan- els provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional I smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- iOUD-7 are compatible with conventional input devices such I as two- and four-wire smoke detectors, pull stations, waterf low devices, tamper switches, and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete listing of compatible devices. I Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. I New options include a UL listed printer, PRN-6F and FireLite's new IPDACT Internet Monitoring module. The IPDACT permits monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. I Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-I0UD-7E offers the same features as the MS- I 1OUD-7 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. I Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). I . Style B (Class B) IDC (Initiating Device Circuit) - MS-5UD-3 - five lDCs. - MS-i OUD-7 - ten lDCs. Style Y (Class B) NAC (Notification Appliance Circuit) - spe- I . cial application power - MS-5UD-3 - four NACs. MS-i OUD-7 - four NACs. I - Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. Strobe Synchronization for System Sensor, Wheelock, I - Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-i OUD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-1 OUD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. I DF-52416:B • 07/10/08 - Page 1 014 I USER INTERFACE: I . • Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings I . adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. I • Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS I FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) I . AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS I ACKNOWLEDGE ALARM SILENCE I SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. Maximum Charger Capacity: 18 AH battery for MS-5UD-3, and 26 AH battery for MS-1OUD-7(E). [Two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] Minimum Battery Size: 7 AH. I - Top [ ' _ Depth 5.207" (13.23 cm) Door = 16.821" (42.73 cm) Backbox = 16.65" (42.29 cm) Depth = (13.353T I I I I Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) Left Side Right Side I I Bottom Cabinet Measurements I I Page 2 of 4— DF-52416:B • 07/10/08 I.. I I I I I I I I I Initiating Device Circuits - TB4 (and TB 6 on MS-i OUD-7 only): Alarm Zones 1 -5 on TB 4 (MS-5U D-3and MS-1 OUD-7). Alarm Zones 6- 10 on T136 (MS-1 OUD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits - TB5 (and TB 7 on MS- 1OUD-7 only): Four NACs Operation: Style Y (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for MS-lOU D-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire•Lite Device Compatibility Document for com- patible listed devices Form C Relays - TB8: Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Ordering Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-1101.113-7E: Same as above with 240 VAC FLPS-7. IPDACT: Internet monitoring module. Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to J7 on the MS-10UD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIA TORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (A white version is also available: ANN-80-W.) ANN-LED: Mounts in the DP-51050(B) dress panel and pro- vides three LEDs for each zone: Alarm, Trouble, and Supervi- sory. ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-5241 6:B • 07/10/08 - Page 3 of 4 I I - SYSTEM SPECIFICATIONS I System Capacity Annunciators .8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.0 A MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.8 A MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50) 60 HZ, 2.2 A Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00° (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TA-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: —20.00" (50.80 cm.) high —22.5" (57.15 cm.) wide - 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 271C/60 - 80°F Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:214 MEA: MEA: 333-07-E NFPA Standards The MS-5UD-3/MS-10UD-7(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow. and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterilow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Watertlow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of I I I I I I I I I ri I Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. :b dl We cannot cover all specific applications or anticipate all requirements. 0111INEERINS & MflNUFACJUNf All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:13 • 07/10/08 I I 1 fl IPGSM-4G Single or Dual Path Commercial Fire Communicator I General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel (FACP) that has a built-in dialer. This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panels Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include: Cellular only, IP only, or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-1 and 800 PLUS services, providing true redundancy and multipath message delivery. Alternative communication methods are critical in the market- place due to VoIP (Voice over IP), migration from POTS (Plain Old Telephone Service) and growth of digital radio networks. The IPGSM-4Gs single path communications solution allows one technology to be used (Either IP or cellular) to provide the appropriate connectivity to a central station. For added reliabil- ity, our exclusive dual path solution allows both technologies (IF and cellular) to be used together for maximum survivability or for local jurisdiction requirements that specify a dual tech- nology system. The IPGSM-4G is designed to operate over the most common cellular networks including 2G,3G and 4G. Its multi-GSM plat- form technology automatically chooses the best available cel- lular signal in the area based on signal strength and seamlessly self-adjusts to maintain critical life safety communi- cation. In addition, it connects to any type of customer pro- vided Ethernet 10/100 base network connection (LAN or WAN), DSL model or cable modem. Our selectable reporting path feature allows the radio to be configured for a single or dual path solution as well as the appropriate supervision inter- vals based on NFPA 72 requirements. (See diagram below for selectable paths and supervision timing intervals.) Selectable Path Description Supervision Times 2010 GSM Single Path (cellular only) 5 minutes 2010 IP Single Path (IF only) 5 minutes 2010 IF & GSM Dual Path (IF and cellular) 24 hours 2013 GSM Single Path (cellular only) 1 hour 2013 IP Single Path (IP only) 1 hour 2013 IP & GSM Dual Path (IF and cellular) 6 hours Features Saves the cost of two dedicated phone lines. Single or dual path communications. (Can communicate to central station using cellular technology, internet or both. Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Multi-GSM platform compatibility for 2G, 3G and 4G net- works. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) GPRS (2G). Selectable reporting paths and supervision intervals to meet NFPA 72, chapter 26 requirements. (Compliant with NFPA 72 2010 and 2013 supervision requirements.) Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL modem or cable modem. Data transmits over standard contact-ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit). Supports both dynamic (DHCP) or Public and Private Static IP addressing. Built-In Power Supply module: On board charging circuit design accommodates back-up battery. Includes primary power and battery supervision. Diagnostic LEDs: Signal strength and status indicators. Reliable connection: IF and GSM connection tested every day. QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including when message was received, signal strength, and message path used. 7720P Hand-held programmer for easy setup. Operation When an event occurs, the Fire Alarm Control Panel goes off hook to dial the central station. The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel. The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent on configuration). I I - 1 1 I I I U I I I I [I I 1 LJ I I 1 Easy to Program The IPGSM-4G communicator can be pre-programmed using the 7720P programmer to enter all central-station information. This is saved to the IPGSM-4G communicator panel memory. When the IPGSM-40 communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the AlarmNet receiver. .For most installations, the only required parameters are: Primary City ID (two digits) obtained from your monitoring station. Primary Central Station ID (two digits) obtained from your monitoring station. Primary Subscriber ID (four digits) obtained from your mon- itoring station. Communication Module's MAC ID, and MAC CRC number located on outside of box, and inside of the module. All of these parameters are assigned by the monitoring station. NOTE: Some assembly is required. See Installation and Setup Guide #800-12454 for full details. Fire Communicator Capability The IPGSM-4G is compatible with fire panels that use the Contact ID communications format as described in the SIA DC-05 standard. AlarmNet Honeywell's AlarmNet has been the nationwide leader in. alarm communications technology since 1986. A reliable alter- native for the transmission of alarm signals, our radio network provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra- structure support. The AlarmNet network consist of redundant hardware servers, hot back-up databases and generators with battery back-up at all locations to ensure continuity of service. Signals from Alarm-Net are transmitted to the central station's receivers using multiple communications paths consisting of the Internet, radio network or toll-free POTS service. Installation Requirements UL COMPLIANCE To meet UL864/NFPA, ensure the following: IPGSM-4G must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72. IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. IPGSM-4G, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be pro- vided with appropriate standby power. IPGSM-4G must use the 7AH battery (not supplied) to pro- vide 24-hour backup capability. Electrical Specifications Transformer: - Primary 120 VAC, 60Hz, 0.5A. - Secondary: 18VDC, 50VA. Battery: - One 12 V 7.0 AH lead-acid battery (not supplied). - Battery charging current: 1 Amp maximum. - Battery discharge current: Standby 230mA, Active 950mA. Cabinet Specifications Dimensions: 14.875' H x 12.75" W x 3.0" D (37.8 cm H x 32.4 cm W x 7.6 cm D). Color: Red. Shipping Specifications Weight: 5.3 lbs. (6.94 kg). Dimensions: 15.625° H x 13.79" W x 9.25" D (39.7 cm H x 34.9 cm W x 23.9 cm D) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93%.-t 2% RH (non condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F Product Line Information IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- cator Panel. Includes red cabinet with Ademco key and lock, wall outlet box, Dialer Capture Module, IGSM Communications Module, antenna & mounting adapter, PowerBoostl power supply, LED display board, transformer, manual, & required screws, cables, etc. Antenna Kits GSM-ANT3DB25KT: 25 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 25' RF cable. GSM-ANT3DB50KT: 50 ft. antenna kit, Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 50' RF cable. Antenna External Hardware GSM-ANT3DB: 3db gain external/remote antenna. WA7626-CA: SNA to N Adapter. 7626-50HC: 50 ft. antenna cable, low loss. 7626-25HC: 25 ft. antenna cable, low loss. NOTE: The GSM-ANT3DB and the WA 7626-CA are both required for installing an external antenna along with the necessary cable needed (7626-50HC: 50 ft. or 7626-25HC: 25 ft.) Other Accessories 7720P: IPGSM-4G hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. BAT-1270: Battery 12 Volts, 7 AH, sealed. Agency Listings and Approvals The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S789. CSFM: 7300-1645:0199. FDNY: COA #6150. I Page 2 of 3— DH-60769:13 • 3/25/13 www.honeyweIl.com I 1 I I I IM I I I I I I II I This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. 02014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Automation I u and Control Solutions E -nEn1eyw!eHoneywell DEI 12 Clintonville Road 1(877) HPP-POWR I Northford, CT 06472-1610 hpp2echserv@honeywell.com www.honeywellpower.corn Dl-l-60769:13 April 2014 Made irr the U.S.A. Iso 9001 ® U.S. Registered Trademark ________________ 02014 Honeywell International Inc. Page 3 of QUALITY SYSTEMS I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION - OFFICE OF THE STATE FIRE MARSHAL I - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7165-0075:0214 Page 1 of I I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 IEmail: Brian.Reynolds2HoneywelI.com DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E, MS-I0UD-7, MS-10UD-7C AND MS10-UD-7E Fire alarm control units. The I MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator I transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that I have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, - and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: I FLPS-3:; Power Supply Module FLPS-7; Power Supply Module I 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module I *ANNSEC; Secondary ANN-BUS Module *lpDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit I meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. I *Rev 04-23-15 gt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2015 Listing Expires June 3O,2016 Authorized By: JAMES PARSEG!AN, Program Coordinator I Fire Engineering Division I. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I .OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 'CAL FIRE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: 7300-1645:0199 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com Models iPGSM-COM, iPGSM-DP, iPGSM-4G and *IGSMCFP4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a control unit accessory for use with separately listed compatible commercial and residential fire alarm control units. *Model IGSMCFP4G is intended for use with specific Honeywell Security control units that employ the ECP bus. Refer to listee's installation Instruction Manual for details. Burglary and other non-fire functions were not examined 1PGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. *Rev 07-01-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct flC' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division