HomeMy WebLinkAbout5545 FERMI CT; ; AS160182; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160182 Job Address: 5545 FERMI CT Status: ISSUED Permit Type: SPRINK Applied 6/9/2016 Parcel No: 2121303700 Approved: 6/21/2016 Reference No.: Issued: 6/21/2016 PC #: Inspector: Project Title: TAYLORMADE BALL MAN. LAB INSTALL WET FIRE SPRINKLER SYSTEM FOR NEW MANUFACTURING LAB IN EXISITNG SPRINKLERED BLDG. Owner: T M G PROPERTY Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 1000 PIONEER WAY EL CAJON CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 348 0 348 0 - - - Fire Protection by Computer Design Schmidt Fire Protection 4760 Murphy Canyon Rd San Diego, CA 92123 (858) 279-6122 Job Name : TMAG Ball Lab TI Building Location 5545 FERMI COURT System 2 Contract : m-8733 Data File TMAG Ball Lab TI.WXF AS 160182 5545 FERMI CT Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Schmidt Fire Protection Page TMAG Ball Lab TI Date Hydraulic Design Information Sheet Name TAYLORMADE BALL LAB Date - 6-3-16 Location - 5545 FERMI COURT Building - System No. - 2 Contractor - SCHMIDT FIRE PROTECTION Contract No. - m-8733 Calculated By - JESUS ROCHA Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 30-0 Occupancy - ORDINARY HAZARD GROUP 2 S (x) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 () Ex.Haz. Y ( ) NFPA 231 ( .) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .20 (x) Wet Make .TYCO D Area Per Sprinkler - 120 ( ) Dry Model TY-FRB E Elevation at Highest Outlet - 29-7 ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - 618.13 Press Required - 44.38 At Node SRC Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 4/29/16 Cap. - T Time of Test - HYD MODEL Rated Cap.- Elev.- E Static Press - 124 8 Press - R Residual Press - 99 Elev. - Well Flow - 6825 Proof Flow S Elevation - 0 U P Location - FERMI COURT P L Source of Information - CITY OF CARLSBAD Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M SR TA O C R K A G E Single Row ( ) Conven. Pallet Double Row ( ) Slave Pallet Mult. Row Flue Spacing Longitudinal Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Transverse Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Schmidt Fire Protection Page 2 TMAG Ball Lab TI Date City Water Supply: Demand: Cl - Static Pressure : 111.6 Dl - Elevation : 7.272 C2 - Residual Pressure: 89.1 D2 - System Flow :368.134 C2 - Residual Flow : 6825 D2 - System Pressure : 44.390 Hose ( Demand) : 250 D3 - System Demand : 618.134 Safety Margin : 66.946 150 140 130 p120 R 110 E 100 C2 S 90 - 580 u 70 R6° E5° U' 40 D 30 20 Dl U 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Schmidt Fire Protection Page 3 TMAG Ball Lab TI Date Fitting Legend Abbrev. Name 1/2 ~ 1 11/4 1% 2 21/2 3 31/ 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139O Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90 Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90 Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 Y Mechanical Tee 2 4 5 6 8 10.5 12.5 15.5 0 22 0 0 0 0 0 0 0 0 0 0 Zwd Watts 709DCDA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Schmidt Fire Protection Page 4 TMAG Ball Lab TI Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. H2 17.79 5.6 18.37 na 24.0 0.2 120 7.0 13 29.58 15.78 na H3 17.79 5.6 18.4 na 24.02 0.2 120 7.0 15 29.58 15.81 na H4 17.79 5.6 18.42 na 24.04 0.2 84 7.0 17 29.58 15.84 na H5 17.79 5.6 18.62 na 24.17 0.2 120 7.0 19 29.58 16.07 na H10 17.79 5.6 19.29 na 24.6 0.2 120 7.0 21 29.58 16.82 na 22 29.58 18.1 na 23 29.58 18.11 na 24 29.58 18.13 na 25 29.58 18.19 na Hil 17.79 5.6 19.3 na 24.6 0.2 120 7.0 27 29.58 16.83 na 1-112 17.79 5.6 19.32 na 24.62 0.2 120 7.0 29 29.58 16.85 na H13 17.79 5.6 19.37 na 24.65 0.2 120 7.0 31 29.58 16.91 na H6 17.79 5.6 19.49 na 24.72 0.2 120 7.0 33 29.58 17.04 na 34 29.58 18.06 na 35 29.58 18.07 na 36 29.58 18.1 na 37 29.58 18.15 na H7 17.79 5.6 19.5 na 24.73 0.2 120 7.0 39 29.58 17.05 na H8 17.79 5.6 19.52 na 24.74 0.2 120 7.0 41 29.58 17.07 na H9 17.79 5.6 19.57 na 24.77 0.2 120 7.0 43 29.58 17.13 na H14 17.79 5.6 20.31 na 25.24 0.2 120 7.0 45 29.58 17.97 na 46 29.58 19.71 na 47 29.58 19.71 na H15 17.79 5.6 20.32 na 25.24 0.2 120 7.0 49 29.58 17.97 na Hi 17.79 5.6 18.37 na 24.0 0.2 120 7.0 2 29.58 15.78 na 3 29.58 17.11 na 4 29.58 17.11 na 5 29.58 17.14 na 6 29.58 17.17 na 7 29.58 17.25 na 8 26.17 21.83 na 9 26.17 21.83 na 10 26.17 21.85 na 11 26.17 21.88 na TOR 25.83 23.39 na BOR 25.83 24.55 na FLG 5.6 33.34 na UG1 1.5 35.13 na BF1 -3.0 37.18 na BF2 -3.0 46.06 na SCR 1.0 44.39 na 250.0 The maximum velocity is 9.37 and it occurs in the pipe between nodes H14 and 45 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 5 TMAG Ball Lab TI Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref."C"or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H2 24.00 1.049 E 2.0 11.790 18.374 K Factor =5.60 to 120.0 0.0 2.000 -5.106 13 24.0 0.1823 0.0 13.790 2.514 Vel = 8.91 13 0.0 1.049 Y 5.0 2.300 15.782 to 120.0 0.0 5.000 0.0 4 24.0 0.1825 0.0 7.300 1.332 Vel = 8.91 0.0 24.00 17.114 K Factor = 5.80 H3 24.02 1.049 E 2.0 11.790 18.396 K Factor 5.60 to 120.0 0.0 2.000 -5.106 15 24.02 0.1825 0.0 13.790 2.517 Vel = 8.92 15 0.0 1.049 Y 5.0 2.300 15.807 to 120.0 0.0 5.000 0.0 5 24.02 0.1826 0.0 7.300 1.333 Vel= 8.92 0.0 24.02 17.140 K Factor = 5.80 H4 24.04 1.049 E 2.0 11.790 18.424 K Factor =5.60 to 120.0 0.0 2.000 -5.106 17 24.04 0.1828 0.0 13.790 2.521 Vel= 8.92 17 0.0 1.049 Y 5.0 2.300 15.839 to 120.0 0.0 5.000 0.0 6 24.04 0.1829 0.0 7.300 1.335 Vel = 8.92 0.0 24.04 17.174 KFactor= 5.80 H5 24.17 1.049 E 2.0 11.790 18.625 K Factor 5.60 to 120.0 0.0 2.000 -5.106 19 24.17 0.1846 0.0 13.790 2.546 Vel = 8.97 19 0.0 1.049 Y 5.0 1.390 16.065 to 120.0 0.0 5.000 0.0 7 24.17 0.1848 0.0 6.390 1.181 Vel = 8.97 0.0 24.17 17.246 KFactor = 5.82 H10 24.60 1.049 E 2.0 11.790 19.294 K Factor 5.60 to 120.0 0.0 2.000 -5.106 21 24.6 0.1908 0.0 13.790 2.631 Vel = 9.13 21 0.0 1.049 V 5.0 1.700 16.819 to 120.0 0.0 5.000 0.0 22 24.6 0.1909 0.0 6.700 1.279 Vel = 9.13 22 0.0 3.26 0.0 10.000 18.098 to 120.0 0.0 0.0 0.0 23 24.6 0.0007 0.0 10.000 0.007 Vel = 0.95 23 24.60 3.26 0.0 10.000 18.105 to 120.0 0.0 0.0 0.0 24 49.2 0.0028 0.0 10.000 0.028 Vel = 1.89 24 24.62 3.26 0.0 10.000 18.133 to 120.0 0.0 0.0 0.0 25 73.82 0.0058 0.0 10.000 0.058 Vel = 2.84 25 24.64 3.26 V 6.72 192.860 18.191 to 120.0 T 20.159 26.879 1.477 10 98.46 0.0099 0.0 219.739 2.182 Vel = 3.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 6 TMAG Ball Lab TI Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 98.46 21.850 KFactor= 21.06 Hil 24.60 1.049 E 2.0 11.790 19.300 K Factor =5.60 to 120.0 0.0 2.000 -5.106 27 24.6 0.1909 0.0 13.790 2.632 Vel = 9.13 27 0.0 1.049 Y 5.0 1.700 16.826 to 120.0 0.0 5.000 0.0 23 24.6 0.1909 0.0 6.700 1.279 Vel = 9.13 0.0 24.60 18.105 KFactor = 5.78 H12 24.62 1.049 E 2.0 11.790 19.324 K Factor = 5.60 to 120.0 0.0 2.000 -5.106 29 24.62 0.1910 0.0 13.790 2.634 Vel = 9.14 29 0.0 1.049 V 5.0 1.700 16.852 to 120.0 0.0 5.000 0.0 24 24.62 0.1912 0.0 6.700 1.281 Vel = 9.14 0.0 24.62 18.133 K Factor = 5.78 H13 24.65 1.049 E 2.0 11.790 19.372 K Factor 5.60 to 120.0 0.0 2.000 -5.106 31 24.65 0.1916 0.0 13.790 2.642 Vel = 9.15 31 0.0 1.049 Y 5.0 1.700 16.908 to 120.0 0.0 5.000 0.0 25 24.65 0.1915 0.0 6.700 1.283 Vel = 9.15 0.0 24.65 18.191 K Factor = 5.78 H6 24.72 1.049 E 2.0 11.790 19.489 K Factor 5.60 to 120.0 0.0 2.000 -5.106 33 24.72 0.1926 0.0 13.790 2.656 Vel = 9.18 33 0.0 1.049 Y 5.0 0.300 17.039 to 120.0 0.0 5.000 0.0 34 24.72 0.1926 0.0 5.300 1.021 Vel= 9.18 34 0.0 3.26 0.0 10.000 18.060 to 120.0 0.0 0.0 0.0 35 24.72 0.0007 0.0 10.000 0.007 Vel = 0.95 35 24.73 3.26 0.0 10.000 18.067 to 120.0 0.0 0.0 0.0 36 49.45 0.0028 0.0 10.000 0.028 Vel = 1.90 36 24.74 3.26 0.0 10.000 18.095 to 120.0 0.0 0.0 0.0 37 74.19 0.0059 0.0 10.000 0.059 Vel = 2.85 37 24.77 3.26 V 6.72 192.860 18.154 to 120.0 T 20.159 26.879 1.477 9 98.96 0.0100 0.0 219.739 2.202 Vel = 3.80 0.0 98.96 21.833 KFactor= 21.18 H7 24.73 1.049 E 2.0 11.790 19.495 K Factor =5.60 to 120.0 0.0 2.000 -5.106 39 24.73 0.1927 0.0 13.790 2.657 Vel = 9.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 7 TMAG Ball Lab TI Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C"or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 39 0.0 1.049 Y 5.0 0.300 17.046 to 120.0 0.0 5.000 0.0 35 24.73 0.1926 0.0 5.300 1.021 Vel = 9.18 0.0 24.73 18.067 K Factor = 5.82 H8 24.74 1.049 E 2.0 11.790 19.519 K Factor 5.60 to 120.0 0.0 2.000 -5.106 41 24.74 0.1929 0.0 13.790 2.660 Vel = 9.18 41 0.0 1.049 Y 5.0 0.300 17.073 to 120.0 0.0 5.000 0.0 36 24.74 0.1928 0.0 5.300 1.022 Vel = 9.18 0.0 24.74 18.095 K Factor = 5.82 H9 24.77 1.049 E 2.0 11.790 19.569 K Factor= 5.60 to 120.0 0.0 2.000 -5.106 43 24.77 0.1933 0.0 13.790 2.666 Vel = 9.20 43 0.0 1.049 Y 5.0 0.300 17.129 to 120.0 0.0 5.000 0.0 37 24.77 0.1934 0.0 5.300 1.025 Vel = 9.20 0.0 24.77 18.154 K Factor = 5.81 H14 25.24 1.049 E 2.0 11.790 20.312 K Factor =5.60 to 120.0 0.0 2.000 -5.106 45 25.24 0.2001 0.0 13.790 2.760 Vel = 9.37 45 0.0 1.049 Y 5.0 3.700 17.966 to 120.0 0.0 5.000 0.0 46 25.24 0.2001 0.0 8.700 1.741 Vel = 9.37 46 0.0 3.26 0.0 10.000 19.707 to 120.0 0.0 0.0 0.0 47 25.24 0.0008 0.0 10.000 0.008 Vel = 0.97 47 25.24 3.26 V 6.72 212.860 19.715 to 120.0 1 20.159 26.879 1.477 11 50.48 0.0029 0.0 239.739 0.691 Vel = 1.94 0.0 50.48 21.883 KFactor= 10.79 HiS 25.24 1.049 E 2.0 11.790 20.319 K Factor 5.60 to 120.0 0.0 2.000 -5.106 49 25.24 0.2001 0.0 13.790 2.760 Vel = 9.37 49 0.0 1.049 Y 5.0 3.700 17.973 to 120.0 0.0 5.000 0.0 47 25.24 0.2002 0.0 8.700 1.742 Vel = 9.37 0.0 25.24 19.715 KFactor = 5.68 Hi 24.00 1.049 E 2.0 11.790 18.367 K Factor 5.60 to 120.0 0.0 2.000 -5.106 2 24.0 0.1824 0.0 13.790 2.515 Vel = 8.91 2 0.0 1.049 V 5.0 2.300 15.776 to 120.0 0.0 5.000 0.0 3 24.0 0.1822 0.0 7.300 1.330 Vel = 8.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 8 TMAG Ball Lab TI Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. PICIP or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 0.0 3.26 0.0 10.000 17.106 to 120.0 0.0 0.0 0.0 4 24.0 0.0008 0.0 10.000 0.008 Vel = 0.92 4 24.00 3.26 0.0 10.000 17.114 to 120.0 0.0 0.0 0.0 5 48.0 0.0026 0.0 10.000 0.026 Vel= 1.84 5 24.02 3.26 0.0 6.000 17.140 to 120.0 0.0 0.0 0.0 6 72.02 0.0057 0.0 6.000 0.034 Vel = 2.77 6 24.04 3.26 0.0 7.590 17.174 to 120.0 0.0 0.0 0.0 7 96.06 0.0095 0.0 7.590 0.072 Vel = 3.69 7 24.17 3.26 V 6.72 189.260 17.246 to 120.0 T 20.159 26.879 1.477 8 120.23 0.0144 0.0 216.139 3.104 Vel = 4.62 8 0.0 6.357 0.0 10.000 21.827 to 120.0 0.0 0.0 0.0 9 120.23 0.0006 0.0 10.000 0.006 Vel = 1.22 9 98.96 6.357 0.0 10.000 21.833 to 120.0 0.0 0.0 0.0 10 219.19 0.0017 0.0 10.000 0.017 Vel = 2.22 10 98.46 6.357 0.0 10.000 21.850 to 120.0 0.0 0.0 0.0 11 317.65 0.0033 0.0 10.000 0.033 Vel = 3.21 11 50.48 6.357 4V 50.294 257.420 21.883 to 120.0 0.0 50.294 0.147 TOR 368.13 0.0044 0.0 307.714 1.356 Vel = 3.72 TOR 0.0 8.249 B 14.094 25.000 23.386 to 120.0 T 41.108 108.055 1.000 **Fixed Loss ....1 BOR 368.13 0.0012 S 52.853 133.055 0.164 Vel= 2.21 Fsp 0.0 BOR 0.0 8.249 I 15.269 7.000 24.550 to 120.0 0.0 15.269 8.762 FLG 368.13 0.0013 0.0 22.269 0.028 Vel = 2.21 FLG 0.0 10.28 L 24.108 10.000 33.340 to 140.0 0.0 24.108 1.776 UG1 368.13 0.0003 0.0 34.108 0.010 Vel = 1.42 UG1 0.0 9.79 2L 43.184 244.000 35.126 to 150.0 0.0 43.184 1.949 BF1 368.13 0.0004 0.0 287.184 0.102 Vel = 1.57 BF1 0.0 10.28 4L 96.43 15.000 37.177 to 140.0 Zwd 0.0 96.430 8.846 * * Fixed Loss = 8.846 BF2 368.13 0.0003 0.0 111.430 0.036 Vel = 1.42 BF2 0.0 9.79 L 21.592 80.000 46.059 to 150.0 G 6.747 95.813 -1.732 SCR 368.13 0.0004 T 67.474 175.813 0.063 Vel = 1.57 250.00 Qa = 250.00 618.13 44.390 KFactor= 92.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Schmidt Fire Protection Page 9 TMAG Ball Lab TI Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Worldwide www.tyco-fire.com Contacts Series RFII - 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFIl Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. LtI)ttI The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. 1Y3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a!9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM!ps11/2 (80,6 LPM!barlt2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPIBI THREAD INTO H [J RETAINER SUPPORT II WITH THREAD CUP UNTIL 0 0 '_- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING t~fSOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. A!L•1t(i Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NPT FRAME SUPPOR CUP WIll ROLL FORk THREAD GUIDE PINS (2) Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and DEFLECTOR I I I L SPRINKLER/SUPPORT CUP ASSEMBLY FLECTOR ROPPED POSITION) EALING SEMBLY CAP BULB IPRESSION CREW 1; -\ 3/16 to 11/16 MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE - PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2(12,7mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER - DIMENSION C Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may beaffect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome........56-792-8-135 56-792-8-165 Chrome........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-x-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. t"1" (Li7L Worldwide L Fire Protection Contacts Products www.tyco-fire.com Series TY-FRB, 5. Upright, Pendent, Quick Response, General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (1Y323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/p5i112 (80,6 LPM/barll2) FEBRUARY 2014 ) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 6 K-factor and Recessed Pendent Sprinklers Standard Coverage TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* _______ _______ NOMINAL 2 : (11,1 mm) ______ _____ 0 11 MAKE-IN (50,8 mm) _____ ____________ I 7/16 1 ______ _____ IIIIh1 (50,8 mm) I (34,9 mm) _ H _ 2" \fl / 1k' I 1-3/8" WRENCH FLATS _______ 1/2 NPT** DEFLECTOR* 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 IN- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8' DIA. (73,0 mm) 2-1/4 DIA. FACE OF - (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH 3/8±5/16 I _____ (9,5±7,9 mm) MOUNTING I 1/8' .J I SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON .2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. -I FITTING (57,2 mm) 5/16±1/4 ( \ 1/2 (7,9±6,4 mm) ' 12,7 mm) FLUSH 717, MOUNTING 118' SURFACE/2 mm) J I CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TEMPERATURE RATINGS 135 135°F(57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) TFPI72 Page 4 of 4 PIN* 77-XXX-X-XXX SIN 370 5.6K UPRIGHT (1/2 NPT) TY313 371 5.6K PENDENT (1/2 NPT) TY323 * Use suffix "I" for ISO 7-1 connection; 1 3 9 SPRINKLER FINISH NATURAL BRASS PURE WHITE (RAL9010)** POLYESTER SIGNAL WHITE (RAL9003) POLYESTER CHROME PLATED for example, 77-370-4-175-I - Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont corporation. Fire Protection Products CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: 5545 Fermi Court SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 5545 Fermi Court CITY: Carlsbad PHONE: ( 858) 279-6122 (Schmidt Fire Protection Co., Inc.) FAX NUMBER: ( 858) 279-3583 Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): North end of Fermi TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 124 PSI Hydrant Number (if applicable):H61024 Elevation of test: 143 (est.) Feet Date/Time of Test': Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 6,825 GPM Residual Pressure 99 PSI At peak demand , this water system is capable of providing a fire flow discharge of no more than 6,825 gpm @ 15 fps. The system can flow in excess of 6,825 gpm at 20 psi, however, this would exceed the maximum allowable velocity of 15 fps. Therefore, the maximum available fire flow is 6,825 gpm. Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: .. Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 /1! Signature: 7 Title/Org:rectManager Date: 04/29/2016 5545 Fermi Court Fire Flow Analysis / CIS/ o... I- 8" '.• ----C Ct oIk I a /4, 8 2o CAM '0 4L a 13 13 1? H61O24 13 a 1 - a N N ,1 a a / U 13 KAV 13 / --a. --..---------------..,..- -----.---..--------------.----.----.-o---.--_..___.___.____ 12 12 a------ / --- Prepared By: Jennifer R. Mael, P.E. - MCS Date: Friday, April 29, 2016 709 OSY Ball Valve Test Cock-- Check Assembly Module Bolted Cover ES-709L Job Name - Contractor Job Location Approval Engineer_ Contractor's P.O. No. Representative - Series 709 Double Check Valve Assemblies Sizes: 21/211 - 10" (65 - 250mm) Series 709 Double Check Valve Assemblies are designed to prevent the reverse flow of polluted water from entering into the potable water system. This series can be applied, where approved by the local authority having jurisdiction, on non- health hazard installations. Series 709 features a modular check design concept to facilitate easy maintenance. Check with local jurisdictional authority as to installation require- ments. Features Replaceable bronze seats Maximum flow at low pressure drop Design simplicity for easy maintenance No special tools required for servicing Captured spring assemblies for safety Approved for vertical flow up installation Models Suffix: NRS - non-rising stem resilient seated gate valves OSY - ULJFM outside stem and yoke resilient seated gate valves S-FDA - FDA epoxy coated strainer BB - bronze body - 21/2 - 3' (64 - 76mm) QT - quarter-turn ball valves QT-FDA - FDA epoxy coated ball valve shutoffs LF - without shutoff valves Specifications A Double Check Valve Assembly shall be installed at referenced cross-connections to prevent the backflow of polluted water into the potable water supply. The cross-connections shall be determined by local inspection authority for use where a high hazard situation does not exist. Valve shall feature modular check assemblies with center stem guiding. Each check module shall have a captured spring and be accessible through a bolted cover plate. Seats shall be replaceable with- out special tools. It shall be a complete assembly including tight-closing resilient seated shutoff valves, test cocks, and a strainer is recommended. The assembly shall meet the requirements of ASSE No. 1015; AWWA C510-92; CSA B64.5 and UL Classified File No. EX3185. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Regulator Company Series 709. Replaceable Resilient Disc Lower Stem Replaceable Seat Guide Check Assembly Module Series 709 features a modular design concept which facili- tates complete maintenance and assembly by retaining the spring load. Also, the first and second check module are identical and can be interchanged. IMPORTAND INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- WWA'FI'S out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Check Valve Bodies: Epoxy coated cast iron Seats: Bronze Pressure - Temperature Temperatures Range: 33°F - 110°F (0.5°C - 43°C) continuous, 140°F (60°C) intermittent Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA C510-92 IAPMO PA 31 USC Manual for Cross-Connection Control, 8th Edition Approvals ®i c us Approved 1015 B64.5 Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Sizes 4" - 10" (100 - 250mm) approved hori- zontal and vertical "flow up". Size 21/2' and 3° (65 - 80mm) approved horizontal only. Factory Mutual approved 4" - 10 (80 - 250mm) vertical "flow up" with OSY gate valves only. Note: Model "S' not listed Dimensions - Weights HM—H N1\ C (open) D SIZE (DN)DIMENSIONS in. mm A in. mm C (OS in. mm C (NRS) in. mm 0 in. mm L in. mm in. If mm M in. mm N in. mm 2½ 65 393/s 1000 16% 416 9% 238 31/2 89 241/8 613 11 279 10 254 6½ 165 3 80 40/e 1025 18/e 479 10¼ 260 33/4 95 241/s 613 14 356 10½ 257 7 178 4 100 52/ 1330 22/4 578 123A6 310 4½ 114 341/8 867 14 356 12'/e 308 81/4 210 6 150 627/8 1597 30'/8 765 16 406 522 140 41% 1057 16 406 18½ 470 13½ 343 8 200 1 75 1905 373/4 959 19A 6 506 1 61/2 165 1 52 1321 1 21 533 1 21% 549 1 15½ 394 10 250 1 90 2286 453/4 1162 2313A6 605 1 8 203 1 64 1626 1 25 635 1 26 660 1 18½ 470 SIZE (DN)DI MENSIONS WEIGHT STRAINER in. mm Nit in. mm A in. mm 130 in. mm I in. mm NAS lbs. kgs. OSY lbs. kgs. 01 lbs. kgs. Weight lbs. kgs. 21/2 65 10 254 4 102 16 406 3 76 167 76 170 77 154 70 28 13 3 80 10 254 5 127 16 406 3 76 167 76 170 77 162 73 34 15 4 100 12 305 6 152 19/4 502 6 152 368 167 383 174 275 125 60 27 6 150 20 508 1 11 279 26 660 71/2 191 627 284 707 321 611 277 122 55 8 200 1 22/4 578 111/4 286 1 11¼ 286 1 9 229 1 1201 545 1 1307 593 1 1419 644 1 247 112 10 250 1 28 711 12½ 318 1 12½ 318 1 101/4 260 1 2003 909 1 2073 940 1 2466 1119 1 370 168 t - Dimension required for screen removal. -C-Quarter-turn (01) valve dimensions. *Service clearance for Check assembly from center. Capacity *Typical maximum system flow rate (7.5 feet/sec.) **UL rated flow kPa psi 21/211 (65mm) 103 15 83 12 62 9 41 6 I2 1 3 0 00 50 100 150 200 250 300 gpm 0 190 380 570 760 950 1140 1pm 5 7.5 10 15 20 fps 1,5 2.3 3.0 4.6 6.1 mps Flow Rate I_ .•____ ._ 1- __--- • [iIir _ MI :11 11111.ilfimii _. _____ I_I_ UI U- IlIwjIiIp _________ • ______ wWATrS® A Watts Water Technologies Company USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscarrada.ca ES-709L 0639 © 2009 Watts