HomeMy WebLinkAbout5545 FERMI CT; ; FPC2017-0314; PermitPERMIT REPORT
4ity of
Carlsbad
Print Date: 03/22/2022 Permit No: FPC2017-0314
Job Address: 5545 FERMI CT, CARLSBAD, CA 92008-7324 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2121303700 Track #: Applied: 10/30/2017
Valuation: $376,358.92 Lot #: Issued: 11/06/2017
Occupancy Group: Project #: Finaled Close Out: 02/18/2020
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check #: Final Inspection:
Project Title:
Description: TMG TAYLORMADE - PGA / KIA REMODEL -SPRINKLER TI 7-100 (84)
Applicant: FPContractor:
WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC
MARIO MACK 13630 DANIELSON ST
13630 DANIELSON ST POWAY, CA 92064-6830
POWAY, CA 92064-6830 (858) 513-4949
(858) 513-4949
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $536.00
Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov
- -
Western Fire Protection Inc.
Material Submittal
Taylormade T.I.
5545 Fermi Court
Carlsbad, CA 92008
Job# TIC-1709
13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 9 Fax: (858) 513-1322
QUICK RESPONSE
UPRIGHT CONVENTIONAL
I N (
QUICK RESPONSE
PENDENT VERTICAL
SIDEWALL
QUICK RESPONSE
HORIZONTAL LPC/CE
SIDEWALL HORIZONTAL
SIDEWALL
yid6
mow
FIRE SPRINKLER CORPORATION
QUICK RESPONSE
A U TO MA TIC SPRINKLERS
GL SERIES
UPRIGHT PENDENT
VERTICAL SIDEWALL
HORIZONTAL SIDEWALL
CONVENTIONAL (OLD STYLE)
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinklers are a
low profile yet durable design which utilizes a 3mm frangible glass
ampule as the thermosensitive element. This provides sprinkler
operation approximately six times faster than ordinary sprinklers.
While the Quick Response Sprinkler provides an aesthetically
pleasing appearance, it can be installed wherever standard spray
sprinklers are specified when allowed by the applicable stan-
dards. It offers the additional feature of greatly increased safe-
ty to life and is available in various styles, orifices, temperature
ratings and finishes to meet many varying design requirements.
Quick Response Sprinklers should be used advisedly and under
the direction of approving authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuat-
ing assembly is a hermetically sealed frangible glass ampule that
contains a precisely measured amount of fluid. When heat is ab-
sorbed, the liquid within the bulb expands increasing the internal
pressure. At the prescribed temperature the internal pressure
within the ampule exceeds the strength of the glass causing the
glass to shatter. This results in water discharge which is distrib-
uted in an approved pattern depending upon the deflector style
used.
TECHNICAL DATA
See reverse side for Approvals and Specifications.
Temperature Ratings - 135°F (570C), 155°F (680C),
175°F (79°C), 200°F (930C), 286°F (141°C)
Water Working Pressure Rating -175 psi (12 Bars)
Factory tested hydrostatically to 500 psi (34 Bars)
Maximum low temperature glass bulb rating is -670F (-55°C)
Frame - bronze • Deflector - brass • Screw - brass
Lodgement Wire - stainless steel • Bulb seat - copper
Spring - nickel alloy • Seal - teflon
Bulb - glass with alcohol based solution, 3mm size
*SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION I AVAILABLE SPRINKLER I I BULB COLOR I N.F.P.A. MAXIMUM
TEMPERATURES CEILING TEMPERATURE
ORDINARY 135°F/155°F 57°c/68°c ORANGE/RED 100°F 38°C
INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°c
HIGH 286°F 141°C BLUE 225°F 107°C
L12óTh GFS-1 00a (Formerly A-20)
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
UPRIGHT PENDENT VERTICAL SIDEWALL
HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE)
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES
2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm)
4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze
5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome
Whit:ster3
8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester 2.3
8.0 (115 metric) I 3/4"NPT (20mm) 2 7/16" (6.2cm)
NOTE: METRIC CONVERSIONS ARE APPROXIMATE.
'HORIZONTAL SIDEWALL IS 29/16".
°FINISHES AVAILABLE ON SPECIAL ORDER.
3AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER.
APPROVALS
TEMPERATURE
STYLE SIN
MODEL
K
FACTOR HAZARD cULus FM LPC CE NYC-DOB
MEA101-92-E 135°F 155°F 175°F 200°F 286°F
(57°C) (68°C) (79°C) (93°C) (141°C)
GL2815 2.8 LH X X X X X X X
GL4215 4.2 LH X X X X X X X
UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X
GL8115 8.0* LH/OH X X X X X X X
GL8118 8.0 LH/OH X X X X X X X X X X
GL2801 2.8 LH X X X X X X X
GL4201 4.2 LH X X X X X X X
PENDENT X I IGL5601 5.6 LH/OH X X X X X X X X X
GL8101 8.0* LH/OH X X X X X X X
GL8106 8.0 LH/OH X X X X X X X X X X
VERTICAL GL5632 5.6 LH X X X X X X X
SIDEWALLt GL8133 8.0 LH X X X X X X --- ---
GL2826 2.8 LH X X X X X X X
HORIZONTAL GL4226 4.2 LH X X X X X X X
SIDEWALL GL5626 5.6 LH/OH X X X X X X X X
GL5627a 5.6 LH/OH X X X X X --- --- X X
GL8127 8.0 LH/OH X X X X X X
CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X
(OLD STYLE) GL8125 8.0 LH/OH X X X X X --- --- X I X
'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS.
§1-tORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4106" BELOW THE CEILING.
DINSTALL IN ACCORDANCE TO 8S5306 AND ANY OTHER RELATED DOCUMENTS.
tPENDENT VERTICAL SIDEWALL CULUS LISTED FOR 6' MIN. SPACING.
fUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING.
OH: ORDINARY HAZARD
LH: LIGHT HAZARD
°1/2" NPT
ORDERING INFORMATION GLOBE® PRODUCT WARRANTY
SPECIFY Globe agrees to repair or replace any of its own manufactured
Quantity • Model Number Style • Orifice products found to be defective in material or workmanship for a
Thread Size • Temperature Finishes desired period of one year from date of shipment.
Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List
PIN 312366 (L.O.) Terms and Conditions of Sale (Our Price List).
114 bLqU
FIRE SPRINKLER CORPORATION
APR 2017
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
989-846-4583 FAX 989-846-9231
1-800-248-0278 www.gIobesprinkler.com
PRINTED U.S.A. GFS-lOoa (Formerly A-20)
Western Fire Protection Inc.
Material Submittal
Taylormade T.I.
5545 Fermi Court
Carlsbad, CA 92008
Job# TIC-1709
13630 Danielson Street • Poway, CA 92064 9 Phone: (858) 513-4949 9 Fax: (858) 513-1322
QUICK RESPONSE
UPRIGHT CONVENTIONAL
QUICK RESPONSE
PENDENT VERTICAL
SIDEWALL
QUICK RESPONSE
HORIZONTAL LPC/CE
SIDEWALL HORIZONTAL
SIDEWALL
now
FIRE SPRINKLER CORPORATION
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
UPRIGHT 'PENDENT
VERTICAL SIDEWALL
HORIZONTAL SIDEWALL
CONVENTIONAL (OLD STYLE)
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinklers are a
low profile yet durable design which utilizes a 3mm frangible glass
ampule as the thermosensitive element. This provides sprinkler
operation approximately six times faster than ordinary sprinklers.
While the Quick Response Sprinkler provides an aesthetically
pleasing appearance, it can be installed wherever standard spray
sprinklers are specified when allowed by the applicable stan-
dards. It offers the additional feature of greatly increased safe-
ty to life and is available in various styles, orifices, temperature
ratings and finishes to meet many varying design requirements.
Quick Response Sprinklers should be used advisedly and under
the direction of approving authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuat-
ing assembly is a hermetically sealed frangible glass ampule that
contains a precisely measured amount of fluid. When heat is ab-
sorbed, the liquid within the bulb expands increasing the internal
pressure. At the prescribed temperature the internal pressure
within the ampule exceeds the strength of the glass causing the
glass to shatter. This results in water discharge which is distrib-
uted in an approved pattern depending upon the deflector style
used.
TECHNICAL DATA
See reverse side for Approvals and Specifications.
Temperature Ratings - 135°F (57°C), 155°F (68°C),
175°F (79°C), 200°F (93°C), 286°F (141°C)
Water Working Pressure Rating - 175 psi (12 Bars)
Factory tested hydrostatically to 500 psi (34 Bars)
Maximum low temperature glass bulb rating is -67°F (-55°C)
Frame - bronze • Deflector - brass • Screw - brass
Lodgement Wire - stainless steel • Bulb seat - copper
Spring - nickel alloy • Seal - teflon
Bulb - glass with alcohol based solution, 3mm size
'SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
AVAILABLE SPRINKLER CLASSIFICATION I I BULB COLOR I N.F.P.A. MAXIMUM
TEMPERATURES CEILING TEMPERATURE
ORDINARY 135°F11 55°F 57°C/68°C I ORANGE/RED 100°F 38°C
INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C
HIGH 286°F 141°C BLUE 225°F 107°C
APR 2017 GFS-1 ooa (Formerly A-20)
QUICK RESPONSE
A U TO MA TIC SPRINKLERS
GL SERIES
UPRIGHT PENDENT VERTICAL SIDEWALL
HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE)
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES
2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm)
4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze
5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome
White Polyester'
8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23
8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm)
NOTE: METRIC CONVERSIONS ARE APPROXIMATE.
'HORIZONTAL SIDEWALL IS 29/16'.
2FINISHES AVAILABLE ON SPECIAL ORDER.
'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER.
APPROVALS
TEMPERATURE
STYLE SIN
MODEL
K
FACTOR HAZARD cULus FM LPC CE NYC-DOB
MEA 101-92-E 135°F 155°F 175°F 200°F 286°F
(57°C) (68°C) (79°C) (93°C) (141°C)
GL2815 2.8 LH X X X X X X X
GL4215 4.2 LH X X X X X X - X
UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X
GL8115 8.0° LH/OH X X X X X X X
GL8118 8.0 LH/OH X X X X X X X X X X
GL2801 2.8 LH X X X X X X --- X
GL4201 4.2 LH X X X X X X -- X
PENDENT I_GLS6O1 5.6 LH/OH X X X X X X X X X X I
GL8101 8.0* LH/OH X X . X X X X X
GL8106 8.0 LH/OH X X X X X X X X X X
VERTICAL GL5632 5.6 LH X X X X X X X
SIDEWALLt GL8133 8.0 LH X X X X X X ---
GL2826 2.8 LH X X X X X X X
HORIZONTAL GL4226 4.2 LH X X X X X X X
SIDEWALL GL5626 5.6 LH/OH X X X X X X X X
GL5627rx 5.6 LH/OH X X X X X --- --- X X
GL8127 8.0 LH/OH X X X X X X
CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X
(OLD STYLE) GL8125 8.0 LH/OH X X X X X --- --- X X ---
'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS.
§HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING.
INSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS.
tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING.
tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING.
OH: ORDINARY HAZARD
LH: LIGHT HAZARD
°1/2" NPT
ORDERING INFORMATION . GLOBE® PRODUCT WARRANTY
SPECIFY Globe agrees to repair or replace any of its own manufactured
Quantity . Model Number . Style • Orifice products found to be defective in material or workmanship for a
Thread Size • Temperature • Finishes desired period of one year from date of shipment.
Quantity - Wrenches - P/N 325390 (1/2")' For specific details of our warranty please refer to Price List
P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List).
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
- 989-846-4583 FAX 989-846-9231
0916LO", 1-800-248-0278 www.globesprinkIer.com
FIRE SPRINKLER CORPORATION
APR 2017 PRINTED U.S.A. GFS-100a (Formerly A-20)