Loading...
HomeMy WebLinkAbout5545 FERMI CT; ; FPC2017-0314; PermitPERMIT REPORT 4ity of Carlsbad Print Date: 03/22/2022 Permit No: FPC2017-0314 Job Address: 5545 FERMI CT, CARLSBAD, CA 92008-7324 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121303700 Track #: Applied: 10/30/2017 Valuation: $376,358.92 Lot #: Issued: 11/06/2017 Occupancy Group: Project #: Finaled Close Out: 02/18/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: TMG TAYLORMADE - PGA / KIA REMODEL -SPRINKLER TI 7-100 (84) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov - - Western Fire Protection Inc. Material Submittal Taylormade T.I. 5545 Fermi Court Carlsbad, CA 92008 Job# TIC-1709 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 9 Fax: (858) 513-1322 QUICK RESPONSE UPRIGHT CONVENTIONAL I N ( QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL yid6 mow FIRE SPRINKLER CORPORATION QUICK RESPONSE A U TO MA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (79°C), 200°F (930C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -670F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION I AVAILABLE SPRINKLER I I BULB COLOR I N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F/155°F 57°c/68°c ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°c HIGH 286°F 141°C BLUE 225°F 107°C L12óTh GFS-1 00a (Formerly A-20) QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome Whit:ster3 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester 2.3 8.0 (115 metric) I 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16". °FINISHES AVAILABLE ON SPECIAL ORDER. 3AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEA101-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X X GL4201 4.2 LH X X X X X X X PENDENT X I IGL5601 5.6 LH/OH X X X X X X X X X GL8101 8.0* LH/OH X X X X X X X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X --- --- GL2826 2.8 LH X X X X X X X HORIZONTAL GL4226 4.2 LH X X X X X X X SIDEWALL GL5626 5.6 LH/OH X X X X X X X X GL5627a 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- --- X I X 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §1-tORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4106" BELOW THE CEILING. DINSTALL IN ACCORDANCE TO 8S5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL CULUS LISTED FOR 6' MIN. SPACING. fUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD °1/2" NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • Model Number Style • Orifice products found to be defective in material or workmanship for a Thread Size • Temperature Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List PIN 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 114 bLqU FIRE SPRINKLER CORPORATION APR 2017 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U.S.A. GFS-lOoa (Formerly A-20) Western Fire Protection Inc. Material Submittal Taylormade T.I. 5545 Fermi Court Carlsbad, CA 92008 Job# TIC-1709 13630 Danielson Street • Poway, CA 92064 9 Phone: (858) 513-4949 9 Fax: (858) 513-1322 QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL now FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT 'PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size 'SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER CLASSIFICATION I I BULB COLOR I N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F11 55°F 57°C/68°C I ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C APR 2017 GFS-1 ooa (Formerly A-20) QUICK RESPONSE A U TO MA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16'. 2FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEA 101-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X - X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0° LH/OH X X X X X X X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X --- X GL4201 4.2 LH X X X X X X -- X PENDENT I_GLS6O1 5.6 LH/OH X X X X X X X X X X I GL8101 8.0* LH/OH X X . X X X X X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X --- GL2826 2.8 LH X X X X X X X HORIZONTAL GL4226 4.2 LH X X X X X X X SIDEWALL GL5626 5.6 LH/OH X X X X X X X X GL5627rx 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- --- X X --- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. INSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD °1/2" NPT ORDERING INFORMATION . GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity . Model Number . Style • Orifice products found to be defective in material or workmanship for a Thread Size • Temperature • Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2")' For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 - 989-846-4583 FAX 989-846-9231 0916LO", 1-800-248-0278 www.globesprinkIer.com FIRE SPRINKLER CORPORATION APR 2017 PRINTED U.S.A. GFS-100a (Formerly A-20)