Loading...
HomeMy WebLinkAbout2470 FARADAY AVE; BLDG 3; FPC2020-0046; PermitE1ii4li1 'flhI (Jity of Carlsbad Print Date: 03/22/2022 Permit No: FPC2020-0046 Job Address: 2470 FARADAY AVE, # BLDG 3, CARLSBAD, CA 92010-7224 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090412600 Track #: Applied: 03/17/2020 Valuation: $69,765.00 Lot #: Issued: 03/30/2020 Occupancy Group: Project #: Finaled Close Out: 05/07/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: BECKMAN COULTER -REPLACE FIRE ALARM CONTROL PANEL & ADD CELL TRANSMISSION (ADDRESSABLE, 9 DEVICES) Applicant: STANLEY SECURITY SCOTT HAINES 13034 CREE DR P0 WAY, CA 92064-3815-SAN DIEGO (858) 276-9742 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ES-50X Intelligent Addressable FACP with Communicator General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire-Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre-installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire-Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features Listed to UL Standard 864, 10th edition. Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator Optional CELL-MOD or CELL-CAB-FL GSM Central Station Communicator over AlarmNet® Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base Multi-criteria detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterfiow selection per module point Alarm verification selection per detector point DF-60953:C (a nre LuTeALarms by Honeywell Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walktest with walktest log & printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional ES- Tools Programming Utility SLC COMMUNICATION LOOP Supports LiteSpeedTM and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 50 addressable device capacity (any combination of addressable detectors and modules) Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NA CS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style V (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24 VOC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time DF-60953:C •7/16/2018 - Page 1 of 4 Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 50 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.firelite.com. User interface LED INDICATORS Fire Alarm (red) CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys Reset (lamp test) Product Line Information ES-50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-50XC, refer to OF- 60954.) FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the ES-50X. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN-80: Remote, red LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DF- 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365: Addressable low-profile photoelectric smoke detector. Lite- Speed only. SD365-IV: Addressable low-profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD365T: Addressable low-profile photoelectric smoke detector with thermal sensor. LiteSpeed only. 5D365T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. S0365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low-profile 135°F fixed thermal sensor. LiteSpeed only. H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- Speed only. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365H1: Low-profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices SD355: Addressable low-profile photoelectric smoke detector. 5D355T: Addressable low-profile photoelectric smoke detector with thermal sensor. 5D355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355C0: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of-rise option. H355H1: Fast-response, low-profile heat detector that activates at 190°F/88°C. Page 2 of 4— DF-60953:C • 7/16/2018 AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (13350LP base included).. B200S: Programmable, addressable sounder base B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFIex low-flow non-relay duct-detector housing; includes SD355R. DNR: lnnovairFlex low-flow non-relay duct-detector housing. (Order SD355R/SD365R separately.) DNRW: InnovairFiex low-flow non-relay duct-detector housing, with NEMA4 rating. Watertight. (Order SD355R/SD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B! A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. BG-I2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SM113500.: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-S0355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BGI2LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES-50X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52 130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MD F-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), 5D355/50355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)/5D350(7) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R47K and R-3.9K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF-60953:C .7/16/2018—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits................................................1 Addressable device capacity....................................................50 Programmable software zones.................................................50 Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 k1 - 22 kK ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80° F. NFPA Standards The ES-50X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). -AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). -REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). - CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. u1IZI FM approved CSFM: 7165-0075:0500 FDNY: COA #6261 NOTE: See DF-60954 for ULC-listed model. AlarmNet®, Fire-Lite® Alarms, SWIFT®, and System SensoP@ are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. = -b All specifications are subject to change without notice. (NINEEINC & MANUFACTURING QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6994105. country of Origin: USA www.firelite.com Page 4 of 4— DF-60953:C •7/16/2018 XA VLY TE LG UAR D tMETEK TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LTE network for sunset-free installations. Meets UL 864 requirements for sole, primary or backup path communications. Minimizes false alarms by providing dual paths for self-tests. Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LTE-A can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7F5 LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as thesole— path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new five or sixty minute supervision modes. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. TELGUARD 41METEK TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS (1< (1) pe,r Pe,eI TG-PFS LTE-A C Lrn,dI,o (OpoI( Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 Canadian commercial burglary alarm systems S559 Equipment for fire signal receiving centres and systems C0123 • Canadian household burglary alarm systems For the most Current product specifications and UL Listings visit www.Telguard.com. SECURITY SIGNALING LJ \lEAaEcTRoNic TY G us ASSOCIATION'" NFPA® Connected LISTED INTERNATIONAL by AT&T Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 • USA 800.229.2326 1 telguard.com • Copyright ©2019 Telguard, a Business Unit of AMETEK, Inc. • All Rights Reserved