Loading...
HomeMy WebLinkAbout2470 FARADAY AVE; BLDG 2; FPC2020-0048; Permittr`~'C- i t y o f Carlsbad L Print Date: 03/22/2022 Permit No: FPC2020-0048 Job Address: 2470 FARADAY AVE, # BLDG 2, CARLSBAD, CA 92010-7224 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090412600 Track #: Applied: 03/18/2020 Valuation: $69,765.00 Lot #: Issued: 03/30/2020 Occupancy Group: Project #: Finaled Close Out: 05/07/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check#: Final Inspection: Project Title: Description: BECKMAN COULTER -ADD 1 DUCT SMOKE DETECTOR AND CONNECT TO EXISTING SYSTEM Applicant: FPContractor: STANLEY SECURITY STANLEY SECURITY SCOTT HAINES 9240 TRADE PL, # STE 300 13034 CREE DR SAN DIEGO, CA 92126-6314-SAN DIEGO P0 WAY, CA 92064-3815-SAN DIEGO (858) 752-1775 (858) 276-9742 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov EQ DATACOM SOLUTIONS Picture represents the product family, not € DATACOM SOLUTIONS Fire Alarm Plenum Rated Unshielded Multiconductor 1814c SQL CMP/FPLP RED 500' BX 213230205 (Legacy #: 5U1804S3135) necessarily this construction. 1.0 Construction 1.1 Conductor 1.1.1 Material: Bare Copper 1.1.2 Size: 18AWG 1.1.3 Conductors: 1.1.4 Construction: Solid 1.2 Insulation 1.2.1 Material: PVC 1.2.2 Color Code: 1.3 Jacket 1.3.1 Material: LSPVC 1.3.2 OD: 0.156 Inches nom. I .32 Color: Red 1.4 Shield 1.4.1 Material: N/A 1.4.2 Coverage: N/A 1.4.2 Drain AWG Size: N/A 1.5 Electrical Properties 1.5.1 Temperature: N/R 1.5.2 Voltage: 300 Volts 1.5.3 Capacitance: 24 pF/Ft. nom. 1.5.4 Impedance: 65 Ohms/M' 1.5.5 Velocity of Propagation: 44 % 1.5.6 DC Resistance: 6.5 Ohms/M' @ 20C 1.6 Put-Ups 1.6.1 Length: 500 1.6.2 Package: BOX 1.6.3 Weight: 30 lbs/i ,000' Compliance: UL 444 UL 910 UL 1424 NEC Article 760 NEC Article 800 The information and specifications described herein are subject to error or omission and to change without notice. Paige provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Paige be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Paige has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM ".2 $ SENSOR RTSI5IKEY(A) 3825 Ohio Avenue, St. Charles, Illinois 60174 Remote Test Station . 1.800.SENSOR2 Fax: 630.377.6495 www.systemsensor.com SPECIFICATIONS Dimensions: 4.6" H x 2.75" W x 1.8" D Weight: 0.24 Lbs. Power Requirements Power LED (Green): 14 - 35 VDC, 12 mA maximum Alarm LED (Red): 2.8 - 32 VDC, 12 mA maximum Alarm Response Time: 40 seconds maximum Temperature: -10°C to 60°C (14°F to 140°F) Humidity: 95% relative humidity, noncondensing Max Listing: UL, FM, CE NOTE: RTS151KEY(A) replaces RTS451KEY. NOTICE: This manual shall be left with the owner/user of this equipment. NOTE: A test coil is required only for use with D2/DNR/DH400/DH500 mod- els. For D2 models order part # DCOIL. For DH400/500 models order part #Coil. GENERAL INFORMATION The System Sensor RTS151KEY(A) is an automatic fire detector accessory de- signed to test remotely located duct and beam detectors. For 4-wire detec- tors, the RTS151KEY(A) features a multi-colored LED that alternates between steady green and red. Green indicates power and that the detector board is in place. Red indicates alarm. For 2-wire detectors, the LED will show red for alarm. Consult the detector installation instructions for additional informa- tion. The National Fire Protection Association has published codes, standards, and recommended practices for the installation and use of this product. It is rec- ommended that the installer be familiar with these requirements, with local codes, and any special requirements of the local authority having jurisdiction. RTS151 CONTENTS 1 RTS151KEY(A) remote test station 1 screw pack (2 mounting screws) 2 Keys OPERATION Test Function Insert the key and turn clockwise to the "TEST" position. Alarm Indication With the key in the "TEST" position, some time will elapse (40 seconds maxi- mum) depending on the detector type, before the alarm indicating LED will turn red. Reset Function Turn the key counterclockwise to the "RESET" position and hold. The LED should turn off. Then, turn the key back to the "NORMAL" position and re- move. The RTS151KEY(A) is capable of resetting only certain models of detec- tors. Refer to the detector installation instructions for additional information. Wiring Instructions Consult the appropriate detector installation instructions for the applicable wiring diagram. The RTSI51KEY(A) mounts to a single gang box (2 h/2 mini- mum depth), or directly to the wall or ceiling. In Canadian applications, the RTS1S1KEY(A) is intended to be located in the same room as the smoke detector and within 60 feet of the unit. FIGURE 1. RTS151KEY(A) H0195-01 FIGURE 2: WIRING DIAGRAM FOR RTS151KEY(A) TO D4120 4-WIRE DUCT SMOKE DETECTOR: RTS451KEV(A) I I D4120 !UA LJU I + FIELD AUX OUT- INSTALLED JUMPER —a, ~; (RED LED) (V-------t95 ALARM —@$- SUP, NO ALARM A TEST SUP, c 3 2 A RESET (GREEN LED) POWER ® up. contacts cannot be used if they are wired to H0582-21 FIGURE 3: WIRING DIAGRAM FOR RTS151KEY(A) TO DNR 2-WIRE DUCT SMOKE DETECTOR WITH REMOTE TEST CAPABLE HEAD: TEST COIL + TEST COIL- 1/RTS451KEY RTS151/RTS151KEY COMM + : OUT (CONV ONLY) + COMM - _F 3 :JUMPER RNRTS- RA+ RTS + 156-0758-016 06-10 FIGURE 6. WIRING DIAGRAM FOR RTS151KEY(A) TO DH100 2-WIRE DUCT SMOKE DETECTOR: NOTE: Terminal 6 of the RTS151KEY(A) is not used when wired to a 2-wire detector. DH100 I I RTS151KEY(A) Test+ ii Test Test / Reset - Reset+ 3 (,) I RA+ 4 Arl1 L1 Reset RA- 5 2 V Out + No Connection H0193-05 FIGURE 4: WIRING DIAGRAM FOR RTS151KEY(A) TO D2 2-WIRE DUCT SMOKE DETECTOR: MAGNET +TESTCOIL TEST I 24VDC I SWITCH —TEST COIL IAUX POWER I POW] SUPPLIED I 2 —9 BYUSER (i.) (100mA ___________ + IN I SUPPLY) I I ® OUT + ALARM 24 VAC (+10%, —15%) LED (RED) 1 + FULL WAVE RECTIFIED, - UNFILTERED POWER MAY BE USED _RA RTS151KEY(A) TEST STATION T (OPTIONAL) + FITS D2 METHOD #1 - AUX POWER LOCATED AT DUCT DETECTOR 24V I J+TESTCOIL AUX POWER MAGNET - TEST COIL SUPPLIED TEST BY USER SWITCH (lOOmA +IN G SUPPLY) +OUT 24 VAC (+10%, —15%) (—) FULL WAVE RECTIFIED, I UNFILTERED POWER ALARM s - MAY BE USED LED (RED) (+) I L () — RA _ RTS151KEY(A) ®+RA (OPTIONAL) REMOTE TEST STATION + FITS D2 METHOD #2 - AUX POWER LOCATED AT TEST STATION NOTE: THE USE OF THE RTS151KEY(A) REQUIRES THE INSTALLATION OF AN ACCESSORY COIL, DCOIL, SOLD SEPARATELY. H0612-12 FIGURE 5 WIRING DIAGRAM FOR RTS151KEY(A) TO DH100ACDC 4-WIRE DUCT SMOKE DETECTOR: DH100ACDCLP RTS151KEY(A) Alarm Signal Q (Red LED) Alarm "sup. contacts cannot I IAux.Power+ &I I be used if they are I Sup. N. 0. wired to control panel. I "1!___cil Sup. COM (Green LED) Power Aux. Power" Reset L® Test H0156-08 FIGURE 7. WIRING DIAGRAM FOR RTS151KEY(A) TO DH400ACDC DUCT FIGURE S. WIRING DIAGRAM FOR RTS151KEY(A) TO BEAM1224/ SMOKE DETECTOR: BEAM1224T SMOKE DETECTOR: DH400ACDC RTS151KEY(A) BEAM 224/BEAM 1 224T RTS151KEY(A) Alarm signal () (Red LED) Alarm . -I * REMOTE ALARM OUT (i') T2-1 (1)(RED LED) ALARM I Aux. Power + * Sup. contacts cannot be used if I Sup. N. 0. they are wired to I control panel. I Sup. COM "t_@ (Green LED) I Power - — Ass. Power— ®- Reset [ GJ 0 AUX(—) RESET INPUT REMOTE TROUBLE OUTPUT TEST INPUT OPTIONAL YELLOW LEO RESET TEST Test () NOTE: RTS151KEY(A) CAN BE USED WITH INTELLIGENT BEAM DETECTOR PRODUCTS. CONSULT INTELLIGENT BEAM DETECTOR MANUAL FOR ADDITIONAL INSTRUCTIONS H0156-09 H0585-04 THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed product to be free from defects in materials and send defective units postage prepaid to: Honeywell, 12220 Rojas Drive, Suite 700, El Paso workmanship under normal use and service for a period of three years from date of TX 79936, USA. Please include a note describing the malfunction and suspected cause manufacture. System Sensor makes no other express warranty for the enclosed product. of failure. The Company shall not be obligated to replace units which are found to be No agent, representative, dealer, or employee of the Company has the authority to in- defective because of damage, unreasonable use, modifications, or alterations occurring crease or alter the obligations or limitations of this Warranty. The Company's obligation after the date of manufacture. In no case shall the Company be liable for any consequen- of this Warranty shall be limited to the replacement of any part of the product which is tial or incidental damages for breach of this or any other Warranty, expressed or implied found to be defective in materials or workmanship under normal use and service during whatsoever, even if the loss or damage is caused by the Company's negligence or fault. the three year period commencing with the date of manufacture. After phoning System Some states do not allow the exclusion or limitation of incidental or consequential dam- Sensor's toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, ages, so the above limitation or exclusion may not apply to you. This Warranty gives you I specific legal rights, and you may also have other rights which vary from state to state. 2 156-0758-016 02016 System Sensor. 06-10 INSTALLATION AND MAINTENANCE INSTRUCTIONS MMF-301 Monitor Module FirelfferALarms by Honeywell One FireLite Place Northford, CT 06472 Phone: 203.484.7161 SPECIFICATIONS Nominal Operating Voltage: 15-32 VDC Average Operating Current: 375 pA (group poll); 350 pA (direct poll); 600 pA Maximum (Communicating, IDC Shorted) EOL resistance: 47K ohms Maximum IDC Resistance: 1,500 Ohms Maximum IDC Voltage: 11 Volts Maximum IDC Current: 450 pA Temperature Range: 32'F to 120' F (0'C to 49' C) Humidity: 10% to 93% Non-condensing Dimensions: 1.3" H x 2.75" W x 0.65" D Wire length: 6" minimum BEFORE INSTALLING This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the opera- tor and local authority that the system will be temporarily out of service. Dis- connect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. GENERAL DESCRIPTION The MMF-301 monitor module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting (see Figure 1). The M1vlF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating çir- cuit for normally open contact fire alarm and security devices. This module can be used to replace an M301 module in existing systems. COMPATIBILITY REQUIREMENTS To ensure proper operation, this module should only be connected to listed compatible system control panels only. FIGURE 1: C1063-00 MOUNTING AND WIRING NOTE: This module is intended to be wired and mounted without rigid con- nections inside a standard electrical box. All wiring must conform to appli- cable local codes, ordinances, and regulations. Connect the red (+) and black (-) wires to the positive and negative loop power leads of the Signaling Line Circuit (SLC). Connect the violet (+) and yellow (-) wires to a two-wire, normally open initiating loop. Install the specified EOL resistor value to terminate the initiating loop. Set the address on the module per job drawings. Install the module in the desired mounting location. FIGURE 2. TYPICAL 2-WIRE STYLE B INITIATING DEVICE CIRCUIT (IDC) CONFIGURATION: UL LISTED COMPATIBLE CONTROL SIGNAL LINE CIRCUIT (SLC) PANEL W TO J 1 JJ— NEXT E ALL WIRING SHOWN IS SUPERVISED AND TENS ONES POWER LIMITED t- (+) W (-) YELLOW VIOLET RED 47k EOL INCLUDED (ELR-47k) C0614-02 156-3654-002 FL-460-004 1 02008 FireLite Alarms Inc. D4120 Duct Smoke Detector The InnovairFIef Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features 4-Wire Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3%-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories Agency Listings LISTED APPROVED SOil 3033744 3242-1653:0207 The InnovairFiex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The lnnovairFlex housing provides ample wiring space, a 3%-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the 04120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFiex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. InnovairFlexTM Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFIex° D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the RTS2-AOS Multi-Signaling Accessory or the RTS151 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 1 b (1.14 kg) Operating Temperature Range: D4120 & D4S: -4° to 158°F(-20° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Storage Temperature Range: D4120 & D4S: -221 to 158°F (-30° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 rn/sec I - Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 pF max. 270 jk max. N/A Reset voltage: 3.0 VDC mm. 2.0 VAC mm. 10 VAC mm. Reset time: (with RTS151) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS © 120VAC 60Hz Alarm initiation contacts: (SPST) 2.OA @ 30 VDC (resistive) Alarm auxiliary contacts: 1 O @30 VDC (resistive); 10A @250 VAC (resistive); ½ HP @240 VAC; 1/4 HP © 120 VAC (DPDT) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose Supervisory contacts: (SPDT) 2.OA @30 VDC (resistive); 2.OA © 125 VAC (resistive) Device Standby Trouble Alarm APA151 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z 0 mA n/a 12 mA Max. RTS1S1/RTS1S1KEY 0mN12rnA n/a 12mAMax. RTS2/RTS2-AOS 3.0mA max 16 mA Max. with strobe: 55 mA max; without strobe 30 mA max Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking ur tab (front locking tab shown below C * Wirina for 4-wire Duct Smoke Detector and Accessories F - POWER INPUTS (NOTE I_ - POWER INPUTS (NOTE 4VAC/D 120 c 120 I I 4 FVAC . I r4 FVAC I I & I I 9 10 I 9 10 I OR I I OR I I AUXILIARY CONTACTS I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB AUXA AUXB N N 1 , , N C N NC N 1 , , N C N I SUPERVISORY CONTACTS SUPERVISORY CONTACTS (NOTE 3) I (NOTE 3) I SUP N.O. SUP C SUP N.O. SUP C. UUFM LISTED 4WE 14 3 14 3 I -IR CONTROL PANEL + ALARM 5 ALARM N.C. ALARM 5 ALARM N.O. ALARM INITIATION INITIATION INITIATION CONTACTS CONTACTS \ LOOP \ - (NOTE 4) ALARM C (NOTE 4) ALARM C -----------J ------------J FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER 1 NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC 50-60Hz. 120VAC Power Inputs accept only 120VAC 50-60Hz. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams. NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. Important Notes on 2:1 Sensor-to-Power Capability 2:1 sensor-to-power capability is not available for all InnovairFiex models. The feature is only available on the D4120 4-wire conventional models. 2:1 sensor-to-power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 t the lNT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX— terminal on unit 1 t the INT/AUX- terminal on unit 2 and so on. Up to 50 D4120 units, 50 D4P120 units, or 50 units of combination may be interconnected. Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced. by three 04P120 units. Therefore, when using the interconnect feature a single DH100ACDC can drive either 9 DH100ACDCs or 27 D4120 units. * NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. SMOKE 7;4 RTS151 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS Ordering Information D4120 4-wire photoelectric low-flow duct smoke detector Accessories D4S 4-wire photoelectric sensor component only D4P120 4-wire photoelectric power board component only, 24 VAC/DC, 120 VAC 2D51 4-wire conventional photoelectric sensor head DST1 Metal sampling tube duct width up to ift (0.3m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3t00.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) APA151 Remote annunciator with piezo alarm ETX Metal exhaust tube duct width ift (0.3m) M02-04-00 Test magnet MHR Mini Horn, Red MHW Mini Horn, White P48-21-00 End cap for metal sampling tubes RA100Z Remote annunciator alarm LED RTS151 Remote test station RTS151KEY Remote test station with key lock RTS2 - AOS Multi-signaling accessory with add on strobe ' 15/'577/J 3825 Ohio Avenue • St. Charles, IL 60174 ©2013 System Sensor, for current product information, including the latest version of this data sheet. PhoneSENSOR". 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systeursensor.coul www.systemsensor.com HVDS00502 • 10/13