Loading...
HomeMy WebLinkAbout5922 FARNSWORTH CT; 101; AS160010; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160010 5922 FARNSWORTH Job Address: CT Permit Type: SPRINK Parcel No: 2120701100 Lot #: 0 Status: ISSUED Applied 1/15/2016 Approved: 3/1/2016 Reference No.: Issued: 3/1/2016 PC #: Inspector: Project Title: CARLSBAD TECH. CLEAN ROOM TI Applicant: ACTION FIRE SYSTEMS CO INC 9185 HARNESS ST SPRING VALLEY CA 619-462-9210 Owner: CARLSBAD TECHNOLOGY INC 5923 BALFOUR CT CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 438 0 438 0 AS1 60010 5922 FARNSWORTH CT 101 Page 1 of 6 NIKJNG4 a MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION The Viking Microfasta Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 RIM LPCB Approved CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar: Approvals ONLY is 5 psi (0.35 bar). Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. The minimum operating pressure for LPCB and CE Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135°F (68 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C)= G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Form No. F_033314 Rev 15.2 Page 2 of 6 MICROFAST® QUICK iu'iiya RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/13 (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench Flat Clip 1J[ Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F033314 Rev 15.2 Page 3 of 6 N Ii<Ime MICROFAST® QUICK l:Il[.11u.L RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature U Color B lb Ordinary 135 °F (57 C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 F (141 C) 225 F (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated a I -I. •1 -. 1• ** Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around I the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 Rev 15.2 Page 4 of 6 N11a F1G MICROFASP QUICK l:II[iu,7A RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart I (UL) The Viking Microfast5 Quick Response KEY ,Ii Finish Pendent Sprinkler VK302 AIX 4-- Escutcheon tI( applicable) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size I Nominal Overall Listings and Approvals' Part SIN ye K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S.metric' Inches mm cULus4 VdS LPCB 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, dY -- D3Z 06662B VK302 Pendent 1/2" 15mm 5.6 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X I -- -- -- 18021 VK302 I Pendent 1/2 15mm 56 1 806 1 21/4 58 AiX B1Y Al I AIX Bl'( D1X ClY8 D1X C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175 °F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 °C), 286 °F (141 °C) Polyester'-', Black Polyes- Viking Micromatic Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter5'6 Y - Standard surface-mounted escutcheon or the (79 °C), and 200 °F (93 °C) 2 - ENT5 Viking Microfasr Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C -155 °F (68 °C), 175 °F (79 °C), and 3-Chrome matic® Model E-1, E-2, or E-3 Recessed Escutcheon 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the D - 155 °F (68 °C), 175 °F (79 °C), 200 °F Viking Microfast5 Model F-1 Adjustable Escutcheon (93 °C), 286 °F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, Ed-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1 003 and 0832-MED-1 008. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 15.2 Page 5 of 6 '1H(II1G MICROFASP QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Approval Chart 2 (FM) -Temperature KEY The Viking Microfast® Quick Response Finish Pendent Sprinkler VK302 A- Escutcheon (if applicable) 1XI Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' NPT BSP U.S. metric2 Inches Number' Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 -, 4L01lL II Ifl17R7V 7IIfl7f I17 06662B VK302 Pendent 1/2' 15 mm 5.6 80.6 2-1/4 58 A1Z, 131Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 1 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings x - Standard surface-mounted escutcheon or the 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200 OF Viking Micromatic® Model E-i Recessed (93 °C), 286 OF (141 °C) Approved Finishes Escutcheon 135 OF (57 °C), 155°F (68 °C), 175°F (79 °C), and i -Brass,Chrome,White Polyester1, Y - Standard surface-mounted escutcheon or the 200 OF (93 °C) and Black Polyester1 Viking Microfast® Model F-i Adjustable Escutcheon, C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-i OF (141 °C) or E-2 Recessed Escutcheon D - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-i Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation quidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of -governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 15.2 Page 60f6 N II(II1G® 4 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ceiling Opening Size: 2-5/16" (58.7 mm) minimum (15 mm) I 2-1/2" (63.5 mm) maximum NPT. .L F14 IQ (54 mm) [i.. _____ '.'_i -.• E1 2i4" P l-3M 2" FL T (57 mm) (44.5 mm) (51 mm) Mm. Installed with a standard Installed with a Microfast Note: At maximum, adapter is 1/8" surface-mounted Model F-I Adjustable exposed 1/2" (12.7 mm) from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8" - (54 mm) - 1-3/4" (44.5 mm) Max. Ceiling Opening Size: 2-5-16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum (28.6 mm) 2" Mm. (51 mm) Max. 1-1/8" (28.6 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 Rev 15.2 Replaces Form No. F_033314 Rev 15.1 (Replaced wrench 16036W/B with 13655W/B) - SYSTEMS ACCEPTANCE A6 I Co c i c Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by the property owner or their authorized agent. All detects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name Date 3 Property address r3 fLALS c..OoRTTt ci c tS 31? Accepted by approving authorities (names) gjj; Address es Plans Installation conforms to accepted plans UN0 Equipment used is approved R-Y s U No If no, explain deviations Has person in charge of fire equipment been instructed as )s UNo to location of control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? Ies U No System components instructions Yes U No Care and maintenance instructions 1Yes U No NFPA25 FerYes Cho Location of Supplies buildings 5 21 FPi2-A1 WC)1'Lrft CT C4iz L56A4Ci9 system Year of Orifice Temperature Make Model manufacture size Quantity rating Vi kilm jo'2, Sprinklers 56 Pipe and Type of pipe fittings Type of fittings I Maximum time to operate Alarm ' Alarm device through test connection valve or - - Type Make I Model I Minutes Seconds flow indicator __________ ______________________________________ Dry valve Q. 0 D Make Model Serial no. Make SMode erial no. me Time water Alarm through test Water Air point reached operated Dry pipe connectiona,b air pressure test outleta,b properly operating test Minutes Seconds psi psi Minutes Seconds Yes No Without D. With explain 2ional_Tre Protection Association FPA 13 Measured from time inspector's test connection is opened. NFPA 13 only requires the 60-second limitation in specific sections. INSTALLATION OF SPRINKLER SYSTEMS Operation L Pneumatic U Electric Hydraulics Piping supervised UYes D.No Detecting media supervised rate from the manual trip, remote, or both control static s? U Yes U No Deluge and Is there an acces facility in each circuit for testing? If n fain preactiori UNo valves Doesed cull operate Do es each circuit operate I Maximum time to Make Model supervision valve release? operate release Yes Yes No I Minutes Seconds Pressure- Location Make and Residual pressure reducing and floor Setting Static pressure (flowing) Flow rate valve test Inlet (psi) Outlet (psi 'nlet (psi) Ouuet (psi) Flow (gpm) [B Indicate means used for forward flow test of backflow device: ~~NIA- c~k :a test Hydrostatic: low When means to test device was opened, was system flow demand created? U Yes U No Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for 2 hours. Differential dry pipe valve clappers shall be left open during the test to prevent damage. All aboveground piping leakage shall be stopped. Test description Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. All piping hydrostatically tested at psi ( bar) for hours If no, state reason Dry piping pneumatically tested U Yes IRINO Nor%k IsoulvIv,61 If Equipment operates properly Yes No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of socliuni.silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? s UNo Tests Drain I Reading of gauge located near water I Residual pressure with valve in test test supply test connection: psi bar) I connection open wide: psi (_____ bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Verified by copy of the Contractor's Material and Test U Yes UN, Other Explain Certificate for Underground Piping. A10 WNW Flushed by installer UYes IM of underground sprinkler piping No ON6 If powder-driven fasteners are used in concrete, U Yes ONo If no, explain has representative sample testing been NIA satisfactorily completed? Blank testing Number used. Locations Number removed gaskets Welding piping U Yes rtify as the sprinkler contractor that welding procedures used complied with UYesUNo the minimpirements of A\NS B2.1, ASME Section IX Welding and Brazin Qualifications, or applicable qualification standard as required by tb Do you certify tha all elding edormed by welders or fdng rators U Yes U No in B2.1, ASME Section Welding qualified accordance with the mini IX Welding and Brazing Qualifications, o licable qualification standard as required by the AHJ? Do you certify that the weld' conducted in comnceocumented 1:3 Yes U No quality control pros 1ao ensure that (1) all discs are retrieved; ( t enings in piping are .snjpetflthat slag and other welding residue are removed; (3) the ital diametej'T piping are not penetrated; (4) completed welds are free from cracks, increte fusion, surface porosity greater than 14s in, diameter, undercut deeper the lesser of 25% of the wall thickness or ½2 in.; and 5) oompii.eted circumferential butt weld reinforcement does not exceed %2 in.? alF Fire Protection Association JlFPA 1,3 (P SYSTEMS ACCEPTANCE Cutouts Do you certify that you have a control feature to ensure that 9Kes No (discs) all cutouts (discs) are retrieved? Hydraulic Nameplate provided If no, explain data nameplate 'DYes To X %S Sprinkler contractor removed all caps and straps? WYes No Date left in service with all control valves open JieZ CA €'1/CC. Remarks Name of sprinkler contractor &IJ01 tire. Tests witnessed by Signatures The property owner or their authorized agent (signed) Title Date For sprinkler contr tor (signed) Title Date izez~ Ilk Additional explanations and notes © 2012 National Fire Protection Association NFPA 13 (p. 3 of 3)