HomeMy WebLinkAbout5740 FLEET ST; ; AS080063; PermitCity of Carlsbad Sprinkler Permit Permit No: AS080063 Job Address: 5740 FLEET ST Permit Type: SPRINK Parcel No: 2111000100 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 4/17/2008 Approved: 4/17/2008 Issued: 4/17/2008 Inspector: Project Title: BUNKSPEED TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: AZTEC FIRE PROTECTION 8109 COMMERCIAL STREET LA MESA, CA (619) 464-5625 Owner: CARLSBAD OCEAN TERRACES L L C C/O THE GARRETT GROUP 43529 RIDGE PARK DR TEMECULA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 tJJCG /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-B - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10(1/2 inch NPT) or Style 40(3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII5I - Upright 2.81K, 112"NPT TY1251 - Pendent 2.81K, 112"NPT TY3151 - Upright 5.61K, 1/2"NPT TY3251 - Pendent 5.61K, 112"NPT TY4151 - Upright 8.01K, 3/4"NPT TY4251 - Pendent 8.01K, 3/4"NPT TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.01K, 1/2"NPT Pagel of 8 DECEMBER, 2007 TFPI5I ESCUTCHEON PLATE SEATING .k* SURFACE 1/2,, I NPT NOMINAL SSU MAKE-IN DEFLECTOR t IL 2 WRENCH FLATS if1 \\ 2-1/4" (57,2 mm) 1-9/16 (39,7 mi Page 2 of 8 TFPI5I 1 - Frame 2 - Button 3 - Sealing Assembly DEFLECTOR CROSS PENDENT UPRIGHT SECTION 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 5 - Compression 7- Bushing orifice seat on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT (TYI 151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 1/2" ** NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" ______ (55,6 mm) 1-1/2' (38,1 mm) 7/16" (11,1 mm) STYLE 10 NOMINAL RECESSED MAKE-IN ESCUTCHEON SSU * DEFLECTOR 7/16" 11,1 mm) "JOMINAL MAKE-IN 2-3/16" (55,6 mm) '\4JWRENC FLATS SSP DEFLECTOR * H— 2-7/8(73,0 mm) DIA. H 1/2 NPT ** 6* 5 4 2 3 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3 151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT SSU * DEFLECTOR CROSS UPRIGHT SECTION TFPI5I Page 3 of 8 ESCUTCHEON 1/2(12,7 mm) STYLE 40 PLATE SEATING 3/4" ** NOMINAL RECESSED SSU SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR _ 1/2" 2-5/16" (12,7 mm) No 4 (58,7 mm) mm) N 'I MAKE-IN 2-1/4 2 1-9/16" 57'rm I (39,7 WRENCH FLATS /• SSP DEFLECTOR 2-7/8" (73,0 mm) DIA. 3/4 NPT * PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4 151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) = 7/16" (11,1 mm) ,,** NOMINAL NPT MAKE-IN WRENCH _I FLATS -.-..- SSP* DEFLECTOR PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Page 4 of 8 TFPI5I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER LEAD COATED I WAX COATED I WAX OVER LEAD COATED 2.8 1/2' NPT PENDENT (TY1251) and UPRIGHT (TYII5I) 135°F/57°C Orange 12,3 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve 1,2 5.6 1/2" NPT PENDENT (TY3251) and UPRIGHT (TY3151) 135°F/57°C Orange 1, 2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 1**,2**, 3** 5** 2**, 3** 5** 360°F/182°C Mauve N/A RECESSED PENDENT (TY3251)* Figure 4 135°F/57°C Orange 1, 2, 3, 4, 5 N/A 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 286°F/141°C Blue 1,2 8.0 NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135°F/57°C Orange 1,2, 3,4, 5, 6, 7 1,2,5 1,2, 3,5 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 1**,2**, 3** 5** 2**, 5** 360°F/182°C Mauve N/A RECESSED PENDENT (TY4251) Figure 5 135°F/57°C Orange 1,2,3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 1,2 8.0 1/2" NPT PENDENT (TY4951) and UPRIGHT (TY4851) 135°F/57°C Orange 1 2, 3,4, 5,6 N/A 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 1500F/66*C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A, LABORATORY LISTINGS AND APPROVALS TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 2.8 PENDENT (TY1251) 1/2 and 175 PSI (12,1 BAR) N/A NPT UPRIGHT (TYII5I) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 1/2" UPRIGHT (TY3151) OR NPT 175 PSI (12,1 BAR) RECESSED PENDENT (TY3251) (SEE NOTE 1) N/A 8.0 PENDENT (TY4251) 3/4" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 8.0 PENDENT (TY4951) 1/2" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar1/2) K = 5.6 GPM/psil'2 (80,6 LPM/barl'2) K = 8.0 GPM/psi1/2 (115,2 LPM/bar1l2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. MOUNTING SURFACE CLOSURE SiS 1/8" (3,2 mm) 1-1/4" (31,8 mm) 3/4"(19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT Page 6 of 8 TFPI5I 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. I (73,0 mm) 3/4"(19,1 mm) 2-1/4" DIA. 1/4"(6,4mm) (57,2 mm) MOUNTING PLATE WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) _ 2-1/4" DIA. I 1/4" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) / MOUNTING / SURFACE/// f CLOSURE SERIES 1-5/16" (33,3 mm)1 TYB 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360 °F/182°C temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the WRENCH RECESS (END 'B' USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH TFPI5I Page 7 of 8 sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TY-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in ac- cordance with local requirements and/or national codes. Page 8 of 8 TFPI5I PIN 57-XXX-X-XXX SPRINKLER TEMPERATURE j_ MODEL/SIN I_ RATING 530 2.8K UPRIGHT (1/2"NPT) TYI151 1 NATURAL BRASS 135 135°F/57C 531 2.8K PENDENT (1/2"NPT) TY1251 4 WHITE POLYESTER 155 155°F/68°C 570 5.6K UPRIGHT (1/2"NPT) TY3151 3 WHITE (RAL9010) * 175 175°F/79°C 571 5.6K PENDENT (1/2"NPT) TY3251 9 CHROME PLATED 200 200°F/93°C 590 8.0K UPRIGHT (3/4'NPT) TY4151 7 LEAD COATED 286 286°F/141°C 591 8.0K PENDENT (3/4"NPT) TY4251 6 WAX COATED 360 360°F/182°C 286°F/141°C MAX. - 560 8.0K UPRIGHT (1/2"NPT) TY4851 - 8 WAX OVER LEAD 561 8.0K PENDENT (1/2"NPT) TY4951 286°F/141°C MAX. Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS ages, including but not limited to labor Procedure Warranty charges, regardless of whether TFBP was informed about the possibility of Products manufactured by Tyco Fire & such damages, and in no event shall When placing an order, indicate the Building Products (TFBP) are war- TFBP's liability exceed an amount full product name. Refer to the Price ranted solely to the original Buyer for equal to the sales price. List for complete listing of Part Num- ten (10) years against defects in mate- The foregoing warranty is made in lieu bers. rial and workmanship when paid for and properly installed and maintained of any and all other warranties. ex- Contact your local distributor for avail- under normal use and service. This press or implied, including warranties ability. warranty will expire ten (10) years from date of shipment by TFBP. No of merchantability and fitness for a par- Sprinkler Assemblies with NPT icular purpose. _ t p__ warranty is given for products or com- This limited warranty sets forth the ex- Thread Connections: Specify: (Specify Model/SIN), Stand- ponents manufactured by companies clusive remedy for claims based on ard Response, (specify K-factor), not affiliated by ownership with TFBP or for products and components which failure of or defect in products, materi- als or components, whether the claim (specify temperature rating), Series have been subject to misuse, improper is made in contract, tort, strict liability TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or installation, corrosion, or which have or any other legal theory. coating), P/N (specify from Table C). not been installed, maintained, modi- fied or repaired in accordance with ap- This warranty will apply to the full ex- plicable Standards of the National Fire tent permitted by law. The invalidity, in whole or part, of any portion of this Recessed Escutcheon: Specify: Style (specify 10 or 40 ) Re- Protection Association, and/or the standards of any other Authorities warranty will not affect the remainder. cessed Escutcheon with (specify*) fin- Having Jurisdiction. Materials found ish, P/N (specify*). by TFBP to be defective shall be either * Refer to Technical Data Sheet TFP770. repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor Sprinkler Wrench: authorizes any person to assume for it, Specify: W-Type 6 Sprinkler Wrench, any other obligation in connection with P/N 56-000-6-387. the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or mac- P/N 56-850-4-001. curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 any other legal theory, for incidental, Limited indirect, special or consequential dam- Ordering