Loading...
HomeMy WebLinkAbout6191 EL CAMINO REAL; ; FPC2018-0397; Permit(rrcity of Carlsbad • jj1 Print Date: 03/30/2022 Job Address: 6191 EL CAMINO REAL, CARLSBAD, CA 92009-1602 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131002300 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Permit No: FPC2018-0397 Status: Closed - Finaled Applied: 12/06/2018 Issued: 12/19/2018 Finaled Close Out: 02/24/2021 Inspector: Final Inspection: Project Title: Description: VIASAT BLDG 4 SCC PROJECT (1ST & 2ND FLR) -FIRE ALARM TI - EXPAND & MODIFY EXISTING FIRE ALARM SYSTEM Applicant: iii ENTERPRISES SALOMON GOMEZ 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 x216 FPContractor: THE STEINHILBER CORPORATION 533 5 VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE Plan Review Per Hour - Overtime $608.00 Total Fees: $608.00 Total Payments To Date: $608.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Series RSS and RSSP Strobes and Strobe Plates FIRE L FIRE Series RSS Series RSS Series RSSWP Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/751110cd or the high intensity MCWH strobe with field selectable 1351185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75195cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65' of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. D1 M'EA " APPROVED S5391 151.92-E 7125-0785.141 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/N FPA/UFCIANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 FPC20I8-0397 191 EL CAMINO REAL VIASAT BLDG 4 SOC PROJECT (1ST & 2ND FLR) - FIRE ALARM TI - EXPAND & MODIFY EXISTING FIRE ALARM SYSTEM 2131002300 12/11/2018 FPC20I8-0397 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters, WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION NSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLAIDN INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICAIOfJ, INSTALLATION AND)OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, A1D SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range. Note that NFPA-72 species a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity Dased on UL Standard 1971. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this :hange UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount Ceiling Mount 241575W 24MCW 24MCWH 24MCC: 24MCCH RSS/RSSP Models 1575cd 15cd 30cd 75cd 1100 135cd 185cd 15cd 30cd Thcd 95cd 11 5c 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0,249 0.300 0.420 RSS/RSSP RSS!RSSP Wall Mount 24VDC * RMS current ratings are per UL average RMS method. UL max current - ____________ Models 121575W rating is the maximum RMS current within the listed voltage range (16-3v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at - UL max 0.255 the maximum IIStO vo'tage kjov rorqv units). ror untinereo rvvrc rdung7,. see installation instructions. Table 2: Audi bleslSpeakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-101O/lOSO, E70, ET70 Chimes CH70 Wiring Diagrams SERIES RSS!RSSP APPLIANCE FROM + TO NEXT PRECEDING - APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP - + SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC SYNC CIRCUIT ]ROBE AUDIBLE "NUS I NAC OUT 2 CIRCUIT RETURN SERIES RSS/RSSP APPLIANCES SYNI RONIZD WITH MULTIPLE DSM MODULES DSM #1 F Strobe NAC Cir. lRSS .-3S DSM #2 A Sync: d Strobe NAC Cir, DSM #3 D R3SSS Strobe NAC Cir. IRSE) RSS DSM lnterconnecthg wiring shown. Maximum of Twenty (20) TROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM _____ _______ _______ + APPLIANCE PRECEDING II i II i - OR EOLR APPLIANCE, SYNC MODULE, POWER ____ SUPPLY OR FACP + STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + + TO NEXT PRECEDING APPLIANCE APPLIANCE OR - OR EOLR FACP FROM + ----- +TO KXT = STROBE OR PRECEDING STROBE SYNC - - — fl 1 r - - - _ - SOUl MODULE. POWER SUPPLY ff+ "_0 + STROBE APPLIANCE SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH WHEELOCK POWER SUPPLIES Series PS Power Supplies OUTPUTS :~HnSRSS F 1-4 - 4-CLASS A OR HS RSS C 2-CLASS P HS r._ I I.PISS PS Power EOLR I ° For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refertoWheelock Power Supplies. Snecifications and Orderina Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VOC Color RED Color WHITE Mounting Square or Round Agency Approvals - UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - BD,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - I X 15/30/75/110 1 X - - X BDE,F,G,H,J,N,ORX Square X X X X X RSS.24MCW.AR** 9773 X - X 15/30/75/110 X - - X B,DEF,G,H,JNOR,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,FGH,JN,OR,X Square X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,DE,FG,H,J,NO,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,H,J.NO,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X BDEFG,HJNORX Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,DEFG,H,J,N,O,RX Square X X X X - RSS-24MCC-FR 3157 - X X 15/30/75/95 X X - BDE,F,G,H,JNO,R,X Square X X X X - RSS-24MCCH-F'iN 3461 - X X 115/177 X - - X BD,E,F,GH,JNOR,X Square X X X X - RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,JNO,R,X Square X X X X RSS-24MCWH-FW 3464 X X 135/185 X X B,DE,F,G,H,J,N,O,R,X Square X X X X - RSSWP-2475W-FR 9013 X - X 180@ 77*F X - X - B,DEF,G,H,J,N,O,R,X Square X X X X - RSSWP2475W.FW** 3034 X - X 180@ 77-F X - - X B,DE,F,GH,J,NO,R,X Square X X X X - RSSP-121575W-FR 7798 X - X 115(75onAxis) - X X - D,E,Z Square X - X X X RSSP-24MCW-FR 9402 X X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X I - X 15(75onAxis) - - X - D,E,Z Square X X X X X RSSP-24MCWH-FR 9482 X I X 135/185 X X BDEF,G,H,J,NOR,X Square X X X - - All models sync with Wheelock DSM or Wheelock Power Supplies. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. —Refer to data sheet S7000 for mounting options. A stands for Agent Lettering. Notification Architects ana lngineers speciricauons The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 1351185cd for wall mount and 15/30175/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented. Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard te1558 and conditions. Iifl,,.I1.- WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY . S0410 RSS/RSSP 07/11 . I Series AS Audible Strobe Appliances and Series AH Audibles JIE1 EJ SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/10od, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPAIUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/11Ocd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheel S90Q4 VJ,.L r r I > .: i1EA APPROVED E5946 151-92-8 7125-0785:131 S5391 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. : A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPEIFYI,1G OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURLENT INSTALLATI3N 'IS-RUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICA10N, NSTALLATION ANDIOF OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR 3EATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of I to 2 flashes per second and ADA Guidelines specify a flash rate Df 1 to 3 flashes per second. . All candela ratings represent minimum effective Strobe intensity oased on UL Standard 1971. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior 0 this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0 -33.0 115/177 AS-241575W 24 16.0-33.0 15(75onAxis) AS-121575W 12 8.0-17.5 15 (75 On Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AC '1Affl('AflJ fl4JCIVI '.1 V VI I ')A Cfl l fl •r n I 'J.'J - ,J..J.0 1'11Q I I U.. ASWP-2475W 24 16.0-33.0 Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @10 ft.. © loft. High ,91 '99 Continuous Medium 88 95 Horn Low 83 90 High 87 .99 . Medium 84 ' 95 Code 3 Horn Low 75 @ -31°F 79 . 90 Table 3: Average RMS Current 24 VDC Models Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Mcdels AH-24 AS-241575W AS-24M= AS.24MCWH - AS.24MCC AS-24MCCl 1575cd 15cd 30cd 15cd llOcd 135cd 185cd 15cd 30cc 750d 95cd 115 c 177cd High (99) 24 vdc 0.062 0.100 0.380 0.102 0.160 0.194 0.250 0.320 0.088 0.114 10.165 0.205 0.250 0.323 dBA UL max* 0.080 0.121 0.388 0.125 0.200 0.267 0,355 0.480 0.095 0.133 0.221 0.285 0.355 0.480 Med (95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.3051 0.066 0.092 0.145 0.18€ 0.230 0.305 dBA UL max* 0.043 0.107 0.374 0.110 (.190 0.253 0.340 0.465, 0,080 0.122 0.231 0.26 3.34C 0.465 Low (90) 24 vdc 0.017 0.072 0.D52 0.076 .1 C21 0.158 0,220 0.295' 0.056 0.082 0.132 0. 172 0.22C 0.295 dBA UL max* 0.021 0.100 0.368 0.105 C.182 0.245 0.335 0.460. 0.074 0.113 0.18 0.26 0.335 0.461) Wall Mount ?uuuIpv Audible 12 VDC Models Strobe AH-12 AS-121575W High (99) 12 vdc 0.163 ' 0.260 UL max* 0.192 0.320 dBA Table 4: Average Current* (AMPS) iFor Series ASWP Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max- 0.168 0.155 0.150 12 vdc 0.076 0.195 Med (95) dBA UL max* 0.108 0.275 *RMS current ratings are per UL average RMS method. liLmax curen: rating is the maximum RMS current within the listed votage range (16-33r Low (90) 12 vdc .0.039 0.175 , for 24v units). For strobes the UL max current is usually at The minimum dBA listed voltage (16.v for 24v units). For audibles the max current is usually UL max* 058 0 265 at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installatioc instructions. . Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT PRECEDING + APPLIANCE APPLIANCE OREOLR ORFACP - SERIES AS & ST APPLIANCES SYNCHRONIZED WITH WHEELOCK POWER SUPPLIES oulpulS EOLR '.4 F - 4-CLASS A 8 OR AS St C 2-CLASS P AS ST Sees PS Powe, Supplies SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM 91 - Audible NACCIr Strobe NAC Or. r1 Sync S AS F Audible NAC Cir I I DSM #2 A StrobeNACCir. Sync m L AS AS Audible NAC Cir [I DSM #3 Strobe NAC Cir. f~jync ±L_c DSM Interconnecting wiring shown. Maximum of twenty (20) For detail using DSM Sync Module refer to Data Sheet 53000 or Installation Instructions P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84905 for Wheelock Power Supplies. niffinnc anri ()rdcrinti !nfnrmiition Model Number Order Code Strobe Candela Non- Sync Sync DSM or Wheelock Power 24 VDC 12 VDC Wall Mount Ceiling Mount Supplies Mounting Agency Approvals UL MEA CSFM FM BFP AS-24MCW-FR 9024 15130175/110 X X X - X - A,BD,E,F,GH,J,NO,R,X X X X X X AS-24MCW-FW 9025 15/30/75/110 X I X X - X - A,B,DEF,G,H,J,NO,R,X X X X X X AS-24MCWH-FR 3468 135/185 X X X - - A,BD,EFG,H,JN,O,R,X X X X X - AS-24MCWH-FW 3469 135/185 X X X - X - A,BD,EF,G,H,J,NO,R,X X X X X - AS-241575W-FR 7405 15(75onAxis) X X X - X - A,B,DE,FG,HJN,O,R,X X X X X X AS-121575W-FR 7410 15(75onAxis) X X - X X - A,BDEFG,HJ,NO,R,X X X X X X AS-24MCC-FR 3161 15/30/75/95 X X X - - X A,BDE,FG,H,JNO,R,X X X X X - AS-24MCC-FW 3162 15/30/75/95 X X X - - X A,BDE,F,G,H,J,NO,R,X X X X X - AS-24MCCH-FW 3467 115/177 X X X - - X A,B,D,E,FG,H,JNO,R,X X X X X - ASWP2475WFR** 9012 75 © -31°F X X X - X - I(see Data Sheet S9004) X X X X X AH-24-R 7892 - X X X - X X ABD,E,F,G,H,JN,O,R,X X X X X X AH-24-W 7893 - X X X - X X AB,D,E,F,G,H,J,N,OR,X X X X X X AH-12-R 7891 - X X - X X X ABDE,FG,H,J,NOR,X X X X I X X AH-12-W 7894 - X X - X X X AB,DE,FG,H,J,N,O,R,X X X X X X AH24WPR** 7416 - X X X - X X K X X X - X AH12WPR** 7415 - X X - X X X K X X X - X **For Weatherproof Series AS/AH specifications see data sheet S9004. °I-'ENUINU ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. S8100 AS/All 06/11 Cooper Notification is Wheelock' IMEDCJ SAFEPATH WAVE!S:7) I., Notification nthitect.c and Fnriin&rc Smcifieationc The notification appliances shall be Wheelock Series AS Audible Strobe appliances Frd Series AH Audible appliances or approvec equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protectior Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirement of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision: of circuit wiring by a Fire Alarrr Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range anc shall incorporate a Xenon flashtube enclosed in a rugged LexanO lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronizat on at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mountirg Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required. an NATF (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3YEAR WARRANTY FMM.1 (A), FMM-1 01(A), FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan® General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM-1(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMFIRFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- DN-6720:E NOTIFIER® by Honeywell FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), I com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E • 07/30/2015 - Page 1 of 4 FMM.1 01(A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. e1aui,.a.emnn if ninth In +.i +ka nanal L4Vi*S uuI%JuuILIJI 111.fl.IUIC LU LIUC VOhICI. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. DimenSions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6(15.24 cm) minimum. FZM4 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. 14 15 0 1 ADDRESS 12 3 LOOP 11 4 10 5 76 TENS o 1 • High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. 4 • Direct-dial entry entry of address: 01 - 159 on FlashScan 9 6 loops, 01 —99 on CLIP loops. ON • LED flashes during normal operation; this is a program- mable option. II III.. Il L Illu 10 iII IL.i U.i • —fll 110 0:11 The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All tw-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and T1 1): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E - 07/30/2015 Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing) Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32" to 120°F (0" to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, 0r8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4(10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-1 01 (A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:E . 07/30/2015 - Page 3 014 FlashScan® and NOTIFIER® are registered trademarks and FireWatch is a trademark of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. NIIINBIN a MR13111ININS QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:E • 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt 61I, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division