Loading...
HomeMy WebLinkAbout6195 EL CAMINO REAL; ; FPC2019-0131; Permit13T:I11 •] I Cr'city of Carlsbad Print Date: 03/30/2022 Permit No: FPC2019-0131 Job Address: 6195 EL CAMINO REAL, CARLSBAD, CA 92009-1602 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131001800 Track 1*: Applied: 06/10/2019 Valuation: $0.00 Lot #: Issued: 06/18/2019 Occupancy Group: Project #: Finaled Close Out: 09/26/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: MILLIPORE -FIRE ALARM TI Applicant: SIEMENS CHRIS BISCHEL 10100 WILLOW CREEK RD SAN DIEGO, CA 92131-1636 (858) 265-9894 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov SIEMENS Industry, Inc. I Product Submittals Fire Alarm System 10100 Willow Creek Rd San Diego, Ca 92131 Phone: 858-880-2085 Fax: 855-866-7942 ' •- SAFC 6195 MILPORE SMOKE DETECTOR ADD 6195 EL CAMINO REAL CARLSBAD, CA 92009 FPC20I9-0131 6195 EL CAMINO REAL MILLIPORE - FIRE ALARM TI 2131001800 6/1012019 FPC20I9-0131 SIEMENS Data Sheet Fire Safety Products Desigo' Fire Safety System 50-Point Addressable Fire Alarm Control Panel Model FC2005 ARCHITECT AND ENGINEER SPECIFICATIC Fire alarm control panel (FACP) for up to 50 addressable points that is comprised of the following three (3) system components: Main board (Model FCM901-U2) 6.5 Amps (170-Watt) power supply (Model FP201 1-Ui) System enclosure (Model FH901-U2 I 112) System features: Supports 50 addressable devices on one (1) 'Class A' or two (2) 'Class B' circuits Includes one (1) 'Class A', or two (2) 'Class B' notification appliance circuits Supports Carbon Monoxide (CO) detection Built-in digital alarm communication transmitter (DACT) Built-in RS-485 connection for remote annunciators Supervised remote printer via Desigo's Model FCA2018-U1 Downloads, prints system-event history & detector sensitivity A Resettable and non-resettable 24VDC auxiliary power • i-upi.anum for manu Optional connectivity to a leased-line I city-tie module Off-normal warning message prior to reset • ®UL 864 9th Edition Listed; Fast and easy set-up with custom-configuration tool FM, CSFM & NYC Fire Department Approved; Supports a 182-character display City of Chicago, Class 1 Approval Product Overview Model FC2005 is an intelligent FACP that provides a cost-effective, feature-rich solution for small fire- alarm system applications. Small and compact in design, Model FC2005 is ideal for small fire-protection applications using less than 50 addressable devices: Retail outlets I strip malls • doctors' offices Dry-cleaner shops . restaurants, etc. With its built-in DACT and two (2) NACs, Model FC2005 is powerful enough to economically meet the needs of these applications. Each 50-point FACP has City of Chicago, Class I Approval, as well as being FM (43010); CSFM (471650067:0259) and FDNY (06104) Approved. Specifications The Model FC2005 FACP consists of a main board (Model FCM901-U2); a 170-Watt power supply (Model FP2011-U1), and a Model FH901-U2 I R2 system enclosure. The programming software for Model FC2005 is held in flash electrically erasable programmable read-only memory (EEPROM). Main Board The Model FCM901-U2 main board provides system display and control, as well as connections for system field wiring, via removable terminal blocks. The 3.5-inch (8.9 centimeters) by 1.5" (3.8 centimeters) liquid-crystal display (LCD) screen shows all system messages and event status. Each screen supports 182 characters: seven (7) lines with 26 characters per line. Each event may have a custom message up to 40 characters that describes the event's location. The backlit LCD screen illuminates on any system event or manual key press. New, 'unacknowledged' events are indicated by a flashing exclamation point ('F). Once 'acknowledged,' the exclamation point changes to a check mark ('i'). A system-status line shows the quantity of events presently active. Since Model FC2005 contains a built-in RS-485 communication bus on the main board, Model FCM901-tJ2 main boards readily supports system- status light-emitting diodes (LEDs) for Power, Alarm, Trouble, Supervisory and Ground-Fault commands. Feature-rich solution for Desigo 50-pt. addressable FACPs 6813 SIEMENS Industry, Inc. Building Technologies Division Specifications Main Board -(continued) There are also LEDs to indicate when audible circuits are 'active' or 'silenced.' The main board supports four (4) system-control buttons, including. Acknowledge; Alarm Silence; Unsilence, and Reset. The system offers an off-normal warning feature, alerting users when active devices are not ready for reset. These active devices may include manual stations that have not been reset; smoke detectors with smoke remaining in the optical chamber, etc. Additionally, the main board supports an alphanumeric keypad, as well as navigation keys, which are used for scrolling maintenance functions and system configuration. The main board supports connection for up to 50 addressable devices, via one (1) 'Class A', or two (2) 'Class B' circuits. The loop supports all FDnet devices, including the Desigo Fire Safety and Model 'H'-series devices. The main board also supports one (1) 'Class A' or two (2) 'Class B' NACs. Each NAC supports a maximum 2.5 Amps -with 2.5 Amps, max., allowed between both NACs. Each NAC can be set to a synchronized strobe, for horn- strobe devices, or for audible devices. Audible devices can be set for: 'STEADY 'ANSI Temporal 3'! 'ANSI Temporal 4' 'March Time 30/60/120 Codes' The main board supports four (4) 'Form C' relays for Alarm, Trouble, Supervisory and User Programmable events. Each relay is rated at 2 Amps at 30VDC maximum, resistive. The main board supports two (2) auxiliary 24VDC connections. Upon system reset, one (1) connection interrupts they power for five seconds for use with (4) four-wire conventional detectors: Each auxiliary-power output is 24VDC, nominal - rated at 0.75 Amps. The main board contains a built-in DACT (Model FCA201 5-Ui), which provides communicatior between Model FC2005 and with the central or remote monitoring station. The built-in DACT supports two (2) separate programmable accounts. as well as two (2) connections to the public- switched telephone network. The connections support RJ31X male connectors. (For compatibility with each Model FC2005 FACP, see the Central Station Receiver Compatibility Table on the last page of this data-sheet document.) SIEMENS Industry, Inc. Building Technologies Division The main board contains a battery-charging circuit, providing connection to lead-acid batteries rated at 24VDC, nominal. The main board can charge up to 1 8AH batteries. The main board also cortains a universal serial bus (USB) connector that supports connection for system configuration and module firmware upload, via the custom-configura:ion tool. Model FC2005 can be configured using the custom-configuration tool or manually from the alphanumeric keypad on the main board. An auto- configuration feature :reates a basic system configuration of all connected devices to accelerate initial system commissioning. 50-Point Power Supply The Model FCM901-U2 main board also supports connection to the system power supply. The 6.5 Amps (170-Watt) power supply, Model FP2011-U1, incorporates a 4.OA, non-resettable slow-blow fuse on the primary input. It also includes a built-in AC- line filter for surge and noise suppression. Model FP201 i-Ui mounts in a standard Sierrens - Fire Safety enclosure, and there are no serviceable Siemens - Fire Safety parts to be maintained. 50-Point System Enclosure The Model FH901-U2 I R2 enclosure for the Model FC2005 FACP is available in either black or red, and supports all system modules. The enclosure also supports 1 2A batteries. Note: For systems requiring larger than 12AH batteries, use a ®LJL Listed battery box. The Model FH901-U2 I R2 enclosure for the 50-point panel is comprised of a dual-mounting setup that allows the main board to be partially mounted in a lower-to-upper position. When temporarily installed in the lower position, technicians are allowed more space to install field wiring at the time of system set- up. When field-wiring installation is complete, the main board shall be moved to the upper position for standard mounting prior to applying system power. Additionally, the enclosure supports an optional battery bracket (Model FHA901-Ui) that can be used to secure batteries up to 12AH. Model FHA901-U1 is required to comply with seismic certification, pursuant to ASC I SET 7-05, Section 13.2.2. A flush-mount trim kit (Model FHA902-Ui I Ri) is also available for use when flush mounting Model FH901-U2 I R2. —2— -3- Specifications - (continued) - Optional Accessories - Leased-Line I City-Tie Module The Model FC2005 FACP has the capability of operating an optional leased-line, city-tie module (Model FC12020-U1) that provides a local-energy output for municipal call-box connection. A wiring harness, Model FCA901-U1, is required for use, and must be ordered separately. The leased- line, city-tie module is installed on the back of the Model FC2005 FACP's main board, and all field wiring is connected to the main board. 50-Point Remote Annunciator The fire-system displays (FSD901-U2 I 112) are remote LED / LCD units that show the existing status of the Model FC2005 FACP. The Model FSD901-U2 I R2 optional display supports the following LEDs for system-status conditions: Power Alarm Trouble Supervisory Ground-Fault There are also LEDs to indicate when audible circuits are 'active' or 'silenced.' The main board supports four (4) system-control buttons, including: Acknowledge; Alarm Silence; Unsilence, and Reset. For Model FSD901-U2 I R2, a LED will illuminate for any given Alarm, Supervisory and Trouble Desigo- system event. A 3.5-inch (8.9 centimeters) by 1.5" (3.8 centimeters) LCD screen will give details of the event in alphanumeric form. The display screen can be scrolled to reveal additional events. The Remote Peripheral Module (FCA2018-Ui) provides a means of connecting a Model FC2005 Desigo FACP to a parallel printer for creating a hard copy of system-status events. This supervised, intelligent module contains built-in transient protection and plain-decimal addressing. When Model PAL-1 is used with the remote peripheral module, Model FCA2018-Ui supervises the printer for ON, OFF Line I POWER ON I PAPER OUT PAPERJAM, and wiring-fault conditions, as required by UL for NFPA 72 proprietary systems. These are the dimensions (based upon connection to a one-height-unit enclosure) for Model FC2005: Approximate size: 16.25"(41.3 cm.) [H]; 18.13" (46 cm.) [W]; 5.11" (41.3 cm.) [D] The weight (without operating unit or batteries) is approximately 9 pounds [4082 g]. SIEMENS Industry, Inc. Building Technologies Division LED Annunciator Driver: 32 Outputs 1 16 Inputs Model FT2007-U1 serves as the main component for allowing custom graphic annunciators to operate on Model FC2005 FACPs. There are 16 inputs on each Model FT2007-U1 to accommodate user-defined system commands, which include: Reset; Silence/Unsilence; Acknowledge, and Lamp Test. Inputs can also be programmed as "Generic", which allows additional flexibility for customized functionality. Shipments of each Model FT2007-U1 driver include two (2) PC boards [PCBs]; one (1) built-in RS-485 interface, and one (1) LED driver. Additionally, one (1) ribbon cable is packaged, allowing connectivity between the two (2) PCBs. Tabular Annunciator Drivers: 16 Zones 1 32 Zones The Tabular Annunciators allow system events sent from Desigo 50-point addressable panels to be displayed remotely in real-time. The Model F12008 series of tabular annunciators has 16 zones and the Model FT2009 series uses up to 32 zones. Additionally, no more than two (2) light-emitting diodes (LEDs) can be used per zone. A built-in RS-485 communication bus controls the operation and supervision of the 16-zone and 32- zone Tabular Annunciators, which are available in black or red. Temperature and Humidity Range Model FC2005 is ®UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120 l 3°F (49 2°C) to 32 1 3°F (0 I 2°C) and a relative humidity of 93 1 2% at a temperature of 90 /-3°F (32 /2°C). Related Documentation Product Data Sheet Number Model FP2011-1-11 Power Supply 6806 Leased-Line! City-Tie Module 6810 Remote Peripheral Module 6811 50-Point Remote Annunciator 6817 LED (F12007-U1) Annunciator Driver 6824 16-Zone (FT2008-1-11) I 32-Zone (FT2009-U1) Tabular Annunciators 6825 Central Station Receiver Compatibility Table The following table shows a list of central station receivers that are compatible with the Desigo Fire Safety 50-point addressable system, Model FC2005 - 0 i o 0 00 0 0 0 E E .-' C .c u 0 0 Protocol w W w D1 C W 0 t >< (I LflDi co in M 0 SIA8 Yr Yr Yr Yr Yr Yr Yr SIA2O Yr Yr Yr Yr Yr Yr Yr Ademco " V, V, V, V, Contact ID " 4/2 Yr Yr Yr 3/1 Yr Yr Yr Note: Multiple central station receivers are compatible with the Desigo Fire Safety 50-point FACP, Model FC2005. Although the table above illustrates central station receivers that have been verified by Siemens with the Model FC2005 FACP, additional receivers and formats can also be used with each 50-point addressable system. After completing the installation, communication between the Digital Alarm Communication Transmitter (Model DACT) and Central Station Receiver must be tested and verified. Details for Ordering Model Part Description Number FCM901-U2 S54433-BiOO-Ai Desigo Main Board {for the 50-point FACP} FH901-U2 S54433-B103-Ai System Enclosure, Black {for the 50-point FACP} FH901 -R2 S544_33-B103-A2 System Enclosure, Red {for the 50-point FACP} FP201 i-Ui 500-450222 170-Watt Power Supply Optional Accessories Model Part Description Number FCA201 8-Ui S54400-A65-Ai Remote Peripheral Module FC12020-U1 S54400-A57-A1 Leased-Line I City-Tie Module FCA901-Ui S54433-C1 06-Al Wiring Harness (for use on 50-point addressable panels) FHA90 1-Ui S54433-B1 07-Al Battery Bracket FHA902-U1 S54433-B106-A1 Flush-Mount Trim Kit, Black FHA902-Ri S54433-B106-A2 Flush-Mount Trim Kit, Red FSD901 -U2 S54433-Cl 02-A4 System Display, Black {specifically for the 50-point FACP} FSD901-R2 S54433-Cl 02-A3 System Display, Red {specifically for the 50-point FACP} F12007-Ui S54400-A1;42-Ai LED Annunciator Driver 132 Outputs 116 Inputs FT2008-Ui S54400-A1143-Ai 16-Zone Tabular Annunciator, Black F12008-Rl S54400-A144-Al 16-Zone Tabular Annunciator, Red F12009-Ui S54400-A1145-All 32-Zone Tabular Annunciator, Black FT2009-Ri S54400-A146-Ai 32-Zone Tabular Annunciator, Red Electronics Package Model Part Number Description Desigo Fire Safety Kit for the 50-Point Addressable FACP 170W power supply, Model FP2011-U1 FC2005-L12 S54433C1103Al (Qty. 1) Includes: - System main board, Model FcM901-u2 (Qty. 1) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 Noth Service Road SIEMENS Industry, Inc. Florham Park, NJ 07932 East Oakville, Ontario November 2016 Building Technologies Division Tel: (973) 593-2600 (S11-FS) L6H 0H6 / Canada Supersedes sheet dated 6/2016 FAX: (908) 547-6877 Printed in U.S.A. Tel: [905] 465-8000 (6e' 14) URL: www.USA.siemens.comlDesigo. Fire- Safeti URL: www.Siemens.cA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0067:0259 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Evelyn Esteban (973) 593-6582 Fax (973) 593-6652 Email: evelyn.esteban@siemens.com DESIGN: Models Desigo FC2005-U2,-R2 and Cerberus Pro FC901-U3,-R3 Fire Alarm Control Units. Non-coded; local, auxiliary, remote, proprietary and central station service; automatic or manual waterfiow, and sprinkler supervisory service when used as a remote station (protected premise) unit, proprietary or central station fire receiving unit. Refer to listee's data sheet for additional detailed product description and operational considerations. Basic components: FH90I-U2; Desigo Enclosure (Black) FH901-R2; Desigo Enclosure (Red) FH90I-U3; Cerberus Pro Enclosure (Black) FH90I-R3; Cerberus Enclosure (Red) FHA90 1-UI; Battery Brackets, left/right FCM901-U2; Desigo Main Board FCM90I-U3; Cerberus Main Board FCI2020-UI; City Tie Board (optional) FP20II-UI; Power Supply Unit FSD90I-U2; Desigo Remote Annunciator (Black) FSD90I-R2; Desigo Remote Annunciator (Red) FSD90I-U3; Cerberus Remote Annunciator (Black) FSD90I -R3; Cerberus Remote Annunciator (Red) *FDC10422; Input/Output Module RATING: 120V 60hz 2A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Rev 03-22-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0067:0259 PEge 2 of 2 Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 03-22-12 gt This isting is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has rev[---wed tie ,est results and/or other data but does not make an independent verification of any caims. This listing is not En endorsement or recommendation of the item listed. This listing should not be used to verify correct cpera:iona requirements or installation criterii Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SIEMENS Data Sheet Fire Safety Products Intelligent Detection Devices Intelligent FirePrintTM Multi-Criteria Detector [For use with FireFinder® XLS and FS-250 Panels] Model HFP-11 ARCHITECT AND ENGINEER SPECIFICATIONS Most sophisticated 'detector intelligence' available Easily programmed to match specific hazard profiles from the fire alarm control panel (FACP) FirePrintTM technology to differentiate between deceptive phenomena and an actual fire Supports software-based automatic environmental compensation System logic activation based on any of three (3) inputs from the detector (smoke, heat or neural network) - - - - Remote sensitivity-measurement capability Pre-alarm reporting based on fire-profile selection Polarity insensitive utilizing Sure WireTh technology Now Multi-color detector status light-emitting diode (LED) - Compatible with Model DPU (device programmer/ tester unit) Field-cleanable chamber with replaceable chamber parts available Multi-criteria fire detection for the price of a photoelectric detector Optional fully programmable relay base, audible base and duct housing Detectors are self-testing: complete diagnostics every four seconds • ®UL and OULC Listed; Two-wire operation FM. CSFM & NYC Fire Deoartment ADDroved Product Overview Model HFP-11 utilizes advanced detection technology that allows each detector to distinguish non- threatening deceptive phenomena —such as cigarette smoke, from actual fire hazards, while optimizing detection for the area it is intended to detect. Model HFP-1 1 uses state-of-the-art microprocessor circuitry with error check, detector self-diagnostics and supervision programs. Model HFP-1 us compatible with the Siemens - Fire Safely field device program /test unit (Model DPU), which is a compact, portable, menu-driven accessory for electronically programming and testing detectors, easily and reliably. Model DPU eliminates the need for cumbersome, unreliable mechanical programming methods -such as dials or switches, and reduces installation and service costs by electronically programming and testing the detector prior to installation. Model HFP-1 1 is compatible with FS-250 and Fire Finder XLS FACPs. Specifications Model HFP-1 1 is a plug-in, two-wire and multi-sensor detector (with both photoelectric and thermal inputs) that is compatible with FireFinder XIS and FS-250 series of FACPs. Each detector consists of a dust-resistant, field-cleanable and photoelectric chamber; a solid state, non-mechanical thermal sensor, and microprocessor-based electronics with a low-profile plastic housing. Model HFP-1 1 utilizes state-of-the-art ASIC circuitry and surface-mount technology for maximum reliability. Every Model HFP-1 1 fire detector is shipped with a protective dust cover. Model HFP-1 1 utilizes an infrared light emitting diode (IRLED), and light-sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern. Model HFP-1 1 is®Uriderwriters' Laboratory and ®Underwriters' Laboratory of Canada Listed. FirePrintlM Multi-Criteria Detector 6301 SIEMENS Industry, Inc. Building Technologies Division Specifications - (continued) The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non-smoke, airborne contaminants in such a way as to maintain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles, and is received by the photodiode. Model HFP-1 1 also utilizes a modern, accurate and shock-resistant thermistor to sense temperature changes. Theon-board'FirePrintrm technology allows the detector to first gather smoke and thermal data, a--id then analyze this information in the detector's 'neural network.' By comparing data received with the common characteristics of fires or fire fingerprints, Model HFP-1 1 can compare these 'fire prints' to those of deceptive phenomena that cause other detectors to false alarm. FirePrint The advanced FirePrint technology allows Model HFP-1 1 to accurately determine a true fire hazard from unthreatening, deceptive phenomena. Further, the advanced FirePrint technology will not require a need to use alarm-delaying verification and confirmation techniques, which can increase the probability of losses due to fire. Model HFP-1 1 provides the highest level of detector intelligence available today with a detector / control panel link that allows the user to program the detector for the specific hazard profile, using a simple software menu selection. Model HFP-1 l's FirePrint application monitors input from both the photo chamber and the thermal sensor, evaluating this information with sophisticated mathematical formulas or algorithms, comparing this input to characteristics of both threatening fires and deceptive phenomena that would mislead any ordinary detector. Detectors are optimized by selecting one (1) of the following 11 applications: Office/Retail Lobby Computer room Dormitory Healthcare Parking garage Utility / Transformer room Hostile environment Precious storage Air Duct Warehouse I Light Manufacturing The control panel programs Model HFP-1 1 detector for the protected area without hassle and without confirmation delays. Once optimized for the hazards in the protected area, Model HFP-1 1 provides the best detection. Should the operator or installer forget to program the detector, Model HFP-1 1 will revert to a default setting, allowing operation as an office-environment detector. SIEMENS Industry, Inc. Building Technologies Division The FirePrint technology was developed over years of research and reviewing the results of over 20 years of fire test data in one of the world's most advanced fire-research centers. The results of this research are the mathematical models that form the algorithms used in FirePrint. No other fire detector has this level of intelligence or this amount of research and development supporting its design. The microprocessor's software can identify and disregard false input caused by radio frequency (RFI) and electromagnetic (EMI) interference, while validating all Trouble conditions before annunciating or reporting to the FAG. Model HFP-11 The Model HFP-1 1 detector's microprocessor uses an essential electronically erasable programmable read-only memory (EEPROM) to store the detector's address and other critical operating parameters, including the assigned program values for Alarm and Trouble thresholds. Communication within the detector, as well as between Model HFP-1 1 and the control panel, or with Model DPU (field device programmer/test unit), are supervised and safe-guarded against disruption by reliable, microprocessor-based error checking routines. Additionally, the micro-processor supervises all EEPROM memory locations, and provides a high degree of EEPROM- failure fault tolerance. Model HFP-1 1 determines its operating status to be Normal in Alarm or in Trouble modes, depending on the difference between the alarm threshold values stored in the detector's memory and the detector's latest analog measurement The detector then communicates changes in its status to the control panel. In addition, the FireFinder XLS control panel will sample the value of the analog signal for Model HFP-1 1 over a period of time, in orderto determine if those values indicate excessive buildup in the photo chamber. If such is the case, the FireFinder XLS control panel will indicate the particular detector requires maintenance. Model HFP-1 1 is listed as a self-testing device. The visible light emitting diode (LED) for Model HFP-1 1 flashes green every four (4) seconds to indicate it is communicating with the control panel, as well as to indicate it has passed its internal self-test Should the detector sense a fault or failure within its systems, the LED will flash amber, and the detector will transmit that data to the control panel. A quick visual inspection is enough to indicate the condition of the detector at anytime. If more detailed information is required, a printed report can be provided from the FireFinder XLS FACP, indicating the status and settings assigned to each individual detector. When Model HFP-1 1 moves to the Alarm mode, it will flash red, and will continue flashing until the system is reset at the FACP. Simultaneously, any user-defined, system-alarm functions programmed into the system are activated. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0067:0203 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Evelyn Esteban (973) 593-6582 Fax (973) 593-6652 Email: evelyn.esteban@siemens.com DESIGN: Models FP-11, HFP-11, and *HFPO..1I analog and FPO-11 photoelectric type smoke detectors. Models FP-1, and HFP-1 I also have a supplemental 1350F heat sensor. Model DGH-1 I detector guard housing suitable for use with Models HFP-1 1, *HFPO..1 I and FP-1 I smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These detectors are intended for installation on a vertical wall surface or the ceiling. They are also acceptable for duct application with an air velocity of 0-4000 ft/mm. when used with Models DB-1 1, DB-HR or DB-X1IRS bases. MARKING: Listees name, model number, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's separately listed base Model DB-11, DB-HR or DB-X1IRS (CSFM Listing No. 7300-0067:134) and separately listed compatible fire alarm control units. Model DGH-1 I detector guard housing is listed for use only with FP-11 and HFP-11. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 09-27-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Model DB-i 1 E SIEMENS Data Sheet Fire Safety & Security Products Specialized Detection Devices 'DB' Series Detector Bases Models D132-HR, DB-11 and DB-11E ARCHITECT AND ENGINEER SPECIFICATIONS Each detector base is compatible with Model 'H', "1 1" __-E. and "1 21" series of conventional detectors All bases compatible with the optional Model LK-11 detector-locking kit Each detector base also functions with the addressable ( Model'H' series, as well as Models FD0421, FDOT421, FDOOT441, FDOOTC441 and FDT421 intelligent devices Model DB2-HR Model 0B2-HR is also compatible with ASAtechno!ogyTM detectors Model DB2-HR has backwards compatibility with Siemens Model 'H'-series intelligent detectors -0 Models DB-i 1 and DR-i 1 E mount on a 4-inch square, octagon or single-gang electrical box Model DB-1 1 has plugs to cover the outer-mounting screw holes Model DB-1 1 Model D132-HR mounts on a 4"-square, double- • UL 268 Listed, ®ULC-5529 Listed; gang electrical box FM, CSFM and NYC Fire Department Approved Product Overview The detector bases are low-profile, surface-mounting bases used on various Siemens - Fire Safety conventional and addressable detectors. Model D132-1-111, which is a redesign of Model DB-HR, is compatible with the standard, addressable type of intelligent detectors, as well as those detection devices that operate with ASAtechnoIog. Additionally, Model D132-HR is backward compatible with the Siemens Model 'H'-series intelligent detectors and detector-assigned FACPs. Model DB2-HR can also operate with Siemens 50-point addressable; 252-point addressable; 504-point addressable, and FireFinder5 XLS fire systems. A relay output from the fire detector base for signaling other devices is provided by Model DB2-HR. The detector bases use screw-clamp contacts for electrical connections and self-wiping contacts for better reliability. Further, the bases can be used with the optional Model LK- 11 detector locking kit, which contains 50 detector locks and an installation tool, to prevent unauthorized removal of the detector head. Specifications Models D13-1 1 and DB-1 1 E are the standard bases for Model 'H'-series 11 " and Model "121 "-series conventional detectors, as well as the Model 'H'-series addressable detectors. Model D13-1 1 has a 6-inch (15.2 cm) diameter. The diameter for Model D13-1 1 E is 4.5 inches (11.4 cm). Specifications - (continued) Moreover, Models D13-1 1 and D13-1 1 E mount on a 4"-square, (10.2 cm) octagon or single-gang box. Model D13-1 1 has integral, decorative plugs to cover the outer screw holes. However, Model D82-HR mounts on a double-gang, 4-inch (10.2 cm.) square electrical box. Dimensions I r-----6" (11.4 —.)Diameter I 1,2"(1.27c..) L --- 41ffi" finn I Note: Model D-11 E base detector has a diameter dimension of 4.5" (11.4 cm.). I Mounting Diagram0SOX Model DB2-HR 3.1,2 INCHES2EEP 44NCH SQUARE BOXP ncc RN-0-21-0 BREAK OFF THIS \ BREAK OFF THIS SECTION WHEN \ SECTION WHEN USINGA4-INCH \ USINGADOUBLE- SQUARE BOX 'GANG BOX Notes: The Module Barrier (shown to the right) must be used when Model DB2-HR relay contacts are connected to non-power-limited circuits. Break apart the barrier to the correct size and shape for either the 4-inch square or double-gang box. Install the barrier diagonally into the back box to create two (2), separate compartments with the back box, in order to separate the wires. SIEMENS Industry, Inc. Building Technologies Division Detector Bases ['0 B' Series] 6161 S.-- •-O -. •:- :. •— C - Wiring Diagrams L,cartl,Coatat (IOThPOL*J1TY VWCNWPLCA&E) Dale 01 :@k atflnznflnrliats WIf1fl I. tilt. pmit. .nbl,..Io...ctN.. 2. WW. . taB Sq lund S c.flul. a*cdqaa RWII tC.It.Rle.tt CaSe2 diuutuluynd 0.tIDBIMd.IAN RII uwdS*i atlith. 0MYdltna*.hIBM alaS. RLC.11.ew.tl tc-,aDuy.,, n.c.,,msei-,I t,n..-, Note: Te illustration above is typical wiring for Models DB-1 1 and DB-1 1 E (using Models PE-11, PE-11T, DT-11, 0P121, 0H121, and H1121 detectors). 08-1lt-llE(NO REMOTE CEetCE) DB-IIXRS(REMOTE RELAY BASE) TO EXT BASE DO MDI + + + / USE AN END OF _____ ° IL40 i\0EvE TO INrnATtNr ____ 18 oPTIONAL E CFCUITOf S. RESAr ( 5 Ia SIEMENS IIJSTRY. 6 rN 'coerrAcTs L 0 ________ -' 6 lb c:T -11 — CCEIMTELE TOR MODELS 26 3A.0VDC II 4 00 MDT USE?.N 'The rulay contacts ___ ___ ate shown in the Non-Aiwn,/System Reset condta. ______ TONE' END OF - LINE BA De"Xi Ti-,, illustration above is typical wiring for Models JB 11 and DB liE (using Models FP-1 1 FPT 11 FS DP ES DPT and ES DT de ectors) 05-li (NO REMOTE VICE) OB-tE (REMOTE REIAYBASE) TO NEW BASS DO NOT E11-II use M MDOc To a pie INTIATING _______ 5 la II 1 ajiroc SIEMENS REMDTE ALARM i-kH 6 E I01atTR 6 lb I cOMT1&E DkOVDC 4DO / P4ATOR I :ol 0 MODELS _________ NC CONTILUMT _______ __ _ END II 101 EXAN INE 'The r&ay NOTE: SFP-11 LINE r*______ / Reset condition. '32=4 s a polarity IteesskIee thtect01. LMe use in Canada 01*. 1 and Une 2 OF 13 I'EXT BASE DEVICE can be e(th*r e of th010q '°HFP-lIIHFPT-ll/}FPO-ltGFP-ll/SFPT.lIISFPO-ll ccl,tacts are shoes in the Non.Aiatm/Syste.n Sales delaclats are proved f Note Th° illustration above is typical wiring for Models DB 11 and DB liE (using Models HFP 11 Series and SEP 11 Series detectors)t LPEI teen ioaexT I NOTl OF Lee dl J1 I WOCILM MR CFUTRA7PI3242XE),A TO aeaete eutism a,.xr tEINT1i cGflcti tAM CE. coNlRoM . , SHOYN IN THE I C _10— PESETCONOMN. tIY - iOIa7 Vl LIES LINE DONOTDa,AJ1EMD OFLINEDEVICE VWIESCDMB=WIOTBL'M4WWENlERCItOMMECUWALSO[OfOPPMrMSMCFWVES C&ClED10iitC1Bl B I DCAN DC POKM OR tawoeseazaiED*pUCAil. Note: The illustration above s typical wiring for Model DB2-HR for polarity-insensitive detectors) Details for Ordering Model Number Part Number Description A02-P 500-649706 Air-Duct Housing - AD2-PR 500-649707 Air-Duct Housing with Relay DB-1 1 500-094151 Low-Profile Surface-Mount Base DB-1 1 C 500-095687 Low-Profile Surface-Mount Base [Canada] 08-1 1 E 500-094151 E Smaller-Diameter Detector Base DB-HR 500-033220 Relay Base for'H'-Series Intelligent Detector DB2-HR S54370-F1 2-Al Relay base compatible with 'S-Line and c-me detectors; backwards compatible with Mode: 'H'-series detectors 01-11 500-095430 135°F {57.2°C}Low-Profile Thermal Detector DT-1 1 C 500-095983 Low-Profile Thermal Detector [Canada] FD0421 554320-F4-A1 Photoelectric Smoke Detector F001421 1 554320-F6-A1 Addressable Multi-Criteria Fire Detector FDT421 S5432045-A1 Thermal (Heat) Detector F000T44I 554320-F7-A1 Multi-Criteria Fire Detector with ASAtechnoIogy° FDOOTC441 S54320-F8-A1 Multi-Criteria Fire/CO Detector with ASAtechnoIogy1° LK-1 1 500-695350 Base Locking Kit for Model '11 '-series detectors Model Number Part Number Description FP-1 1 500-095112 FirePrint Intelligent Detector FP-1 1 C 500-095112C FirePrint'm Intelligent Detector [Canada] FPT-1 1 500-095918 Thermal Detector FPT-1 1 C 500-095918C Thermal Detetor [Canada] HFPO-1 1 500-034800 FS-250 Addressable Ce:ector HFP-1 1 500-033290 FirePrintT' Detector HFPT-1 1 500-033380 Thermal Detector HI1 21 554372-F3-A1 Heat Detector, 0H121 554372-F2-A1 Multi-Sensor Smoke Detector 0P121 554372-Fl-Al Photoelectric Smoke Detector PE-1 1 500-094150 Conventional 2hotoelectric Smoke Detector PE-1 1 500-095150 Photoelectric Smoke Detector with 135°F (57.2°C} Thermal Sensor SFP-1 1 500-33290C Photo I Thermal Detector [Canada] SFPO-11 500-34800C Photo Detector [Canada] SFPT-1 1 500-033380C )etector Package [Carada] - - Notice: This marketing data sheet is not intended to be used for system design or installation purposes. . For the most up-to-date information refer to each products installation instructions Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc... Florham Pars, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 (sll-Fs) L6T 5E4 I Canada September 2012 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 5Upers.edls sheet dated 4/12 URL: www.usa.Siemens.com/Fire FAX: (905) 799-9858 Specifications - (continued) Detector sensitivity, calibration and identification are dynamically supervised at the respective FACP. Detector sensitivity and pre-alarm levels are a function of the application chosen at the control panel, and are controlled by the panel. If an alternate, non-FirePrint mode is selected, then the sensitivity can be changed from the control panel. All Model HFP-1 1 detectors use a surface mounting base, Model DB-1 1, which mounts on a 4-inch octagonal, square or single gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self-wiping contacts for increased reliability. Model DB-1 1 can be used with the optional Model LK-1 1 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-1 1 has integral decorative plugs to cover the outer mounting screw holes. Model HFP-1 1 may be installed on the same initiating circuit with Model HMS-series manual stations; Model HTRI-series interfaces; Model HCP output-control devices, or Model HZM series of addressable, conventional zone modules. All Model HFP-1 1 detectors can be cleaned in the field - when required -via easily removing the detector cover and unsnapping the photo chamber. There is also the option of cleaning the interior of the detector with a clean, soft cloth or brush - or by replacing the labyrinth and bug screen included in the detector maintenance kit, Model DMK-1 1. All Model HFP-1 1 detectors are approved for operation within the ®U L-specified temperature range of 32 to 100°F (0 to 38°C). Model DPU The Device Program /Test Unit accessory is used to program and verify the address of the detector. The technician selects the accessory's program mode, and enters the desired address. Model DPU automatically sets and verifies the address and tests the detector. Model DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment from practically any location. When in 'test' mode, Model DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. SIEMENS Industry, Inc. Building Technologies Division Application Data Installation of the Model HFP-1 1 series of fire detectors requires a two-wire circuit. In many retrofit cases, existing wiring may be used. T-tappirig' is permitted only for Style 4 (Class B) wiring. Model HFP-1 1 is polarity insensitive, which can greatly reduce installation and debugging time. Model HFP-1 1 fire detectors can be applied within the maximum 30 foot center spacing (900 sq. ft. areas,) as referenced in NFPA 72. This application guideline is based on ideal conditions, specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire-protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens - Fire Safety distributor or sales office whenever you need assistance applying FirePrint in unusual applications. Be sure to follow NFPA guidelines and ®UL Listed /'ULC Listed installation instructions—included with every Siemens—Fire Safety detector—and local codes as for all fire protection equipment. Technical Data Operating Temperatures: +32°F (0°C) to 100°F (38°C), per ®UL 268 I 268A Relative Humidity: 0-93% Non-condensing Maximum Spacing: 30-foot Centers (900 Square Feet), per NFPA 72 Chapter 5 and ®ULC-S524 Current Draw: 1 mA in Alarm or Supervisory mode Mniinfinvi fliicirm Details for Ordering Part Mode! Number Description HFP-1 1 500-033290 FirePrint Multi-Criteria Fire Detector DB-1 1 500-094151 Detector Mounting Base for Series 11 DB-1 1 E 500-094151 E Detector Base {small} AD2-P 500-649706 Air-Duct Housing AD2-XHR 500-649708 Air-Duct Housing {with relay} DB-HR 500-033220 Relay Base for H-Series Intelligent Detectors ADBH-1 1 500-033210 Audible Base RL-HC 500-033230 Remote Alarm Indicator: 4" octagon-box mount, red RL-HW 500-033310 Remote Alarm Indicator: Single-gang box mount, red LK-1 1 500-695350 Base Locking Kit for Series 11 Detectors Series 11 Maintenance Kit DMK-1 1 500-695338 {replacement labyrinth and bug screen} In Canada, order Model Part Description Number 1DB-1 1 C 500-095687 Detector Mounting Base for Series 11 Detectors (fULC) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety , Fire Safety 8 Fernwood Road 2 Kenview Boulevard SlEMENSIndustry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 lsll-Fsl L6T 5E4 I Canada June 2015 Supersedes sheet dated 9/13 FAX: (908) 547-6877 Printed in USA. Tel: (905) 799-9937 (Rev. 5( LIRL: wwwjjsa.Siemens.comlFire FAX: (905) 799-9858 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION apt ffih OFFICE OF THE STATE FIRE MARSHAL o FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0067:0134 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Evelyn Esteban (973) 593-6582 Fax (973) 593-6652 Email: evelyn.esteban@siemens.com DESIGN: Models DB4T, D134TS, DB4F, DB4TF, DB4FS, DB3S, ADB3, ADBX3, DB-HR, *DB2..HR DBX3RS, DB-11, DB-XIIRS, ADBI60, ADB-11, ADBH-11,SBGA-34, ADBX-11 and 8837 detector bases and Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3 auxiliary relays. Model DB-1 I is suitable for use only with Model RR-1 I or RR-1 IF auxiliary relay. Models DB-1 I base, ADBH-1 I audible base, and DB-HR, *DB2..HR relay bases are intended to be used with Models HFP-1 1, *HFPO1 1 and HFPT-1 I Intelligent Series smoke and heat detectors (CSFM Listing No. 7272-0067:0223 and 7270-0067:0224). Model SBGA-34 audible base is intended to be used with Models HFP-1 1, HFPT-1 1, or HFPO-1 I detectors (CSFM Listing No. 7272-0067:0223 and 7270-0067:0224), Models FDOT42I, FD0421, 0H921 and 0P921 detectors (CSFM Listing No.7272-0067:0258), Models FDT42I and H1921 detectors (CSFM Listing No.7270-0067:0262), and Models FDOOT44I, FDOOTC44I, 00HC941 and 0OH941 detectors (CSFM Listing No.7270-0067:0260). *Model DB2-HR Relay Base can be used also with Intelligent Series smoke detectors type FDOT421, FD0421, 01-1921, 0P921(CSFM Listing No.7272-0067:0258), FDT421, H1921 (CSFM Listing No.7270-0067:0262), and FDOOT44I, FDOOTC44I, 00HC941, 00H941(CSFM Listing No.7270-0067:0260). Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model DB-1 1, ADBH-1 1, SBGA-34, DB-HR and *DB2HR may be installed on the ceiling or on the wall. MARKING: Listee's name or SIEMENS, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and fire alarm control units. *Rev. 04-15-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division