Loading...
HomeMy WebLinkAbout6195 EL CAMINO REAL; ; FA160004; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160004 6195 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 2131001800 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 1/20/2016 Approved: 3/1/2016 Issued: 3/1/2016 Inspector: Project Title: SAFC 6195 EXPANSION NEW AUDIO-VISUAL NOTIFICATION SYSTEM & NEW ADDRESSABLE DEISGO FC2005 (50-POINT) FIRE ALARM SYSTEM CONTROL PANEL INSTALL A CODE COMPLIANT SYSTEM THROUGHOUT THE ENTIRE AREA OF WORK. Applicant: SIEMENS INDUSTRY INC STEA 1820 JOHN TOWERS AV EL CAJON CA 619-726-3495 Owner: MAMAS HOUSE L L C 6195 EL CAMINO REAL CARLSBAD CA L ._Fees ($) jAddhI Fees ($) Total ($) Balance ($) 497 0 497 0 I I I I I I I I I I Siemens Building Technologies, Inc. FIS Fire I Life Safety Division 10100 Willow Creek Rd San Diego, California 92123 (858) 693-8711 Equipment Submittal FIRE ALARM SYSTEM NEW INSTALLATION For: SAFC 6195 EXPANSION 6195 EL CAMINO REAL CARLSBAD, CA 92009 FAI 60004 6195 EL CAMINO REAL 440P-1 86988 01/15/2016 I I I I I 'I [FIRE ALARM CONTROL PANEL AND ACCESSORIES] L I I I El I I I I I I SIEMENS Data Sheet Fire Safety Products Desigo® Fire Safety System 50-Point Addressable Fire Alarm Control Panel Model FC2005 RCHITECT AND ENGINEER SPECIFICATION Fire alarm control panel (FACP) for up to 50 addressable points that is comprised of the following three (3) system components: Main board (Model FCM901-U2) 6.5 Amps (170-Watt) power supply (Model FP2011-Ui) System enclosure (Model FH901 -U2 I R2) System features: Supports 50 addressable devices on one (1) 'Class A' or two (2) 'Class B' circuits Includes one (1) 'Class A', or two (2) 'Class B' notification appliance circuits (NACs) Supports Carbon Monoxide (CO) detection Built-in digital alarm communication transmitter (DACT) Built-in RS-485 connection for remote annunciators Supervised remote printer via Desigo's Model FCA2018-U1 Downloads, prints system-event history & detector sensitivity Resettable and non-resettable 24VDC auxiliary power Optional connectivity to a leased-line! city-tie module • Alphanui Off-normal warning message prior to reset • for man,, , Fast and easy set-up with custom-configuration tool Supports a 182-character display • ®UL 864 9th Edition Listed; Programmable function keys FM, CSFM & NYC Fire Department Approved I I I Li I I I I Product Overview Model FC2005 is an addressable FACP that provides a cost-effective solution for simple fire-alarm-system applications. Small and compact in design, Model FC2005 is ideal for small fire-protection applications using less than 50 addressable devices: retail outlets I strip malls . doctors' offices dry-cleaner shops . restaurants, etc. With its built-in DACT and two (2) NACs, Model FC2005 is powerful enough to economically meet the needs of these applications. Each 50-point FACP is FM (43010); CSFM (47165-0067:0259) and FDNY (46104) Approved. Specifications The Model FC2005 FACP consists of a main board (Model FCM901 -U2); a 170-Watt power supply (Model FP2011-Ui), and a Model FH901-U2 I R2 system enclosure. The programming software for Model FC2005 is held in flash electrically erasable programmable read-only memory (EEPROM). Main Board The Model FCM901 -U2 main board provides system display and control, as well as connections for system field wiring, via removable terminal blocks. The 3.5-inch (8.9 centimeters) by 1.5" (3.8 centimeters) liquid-crystal display (LCD) screen shows all system messages and event status. Each screen supports 182 characters: seven (7) lines with 26 characters per line. Each event may have a custom message up to 40 characters that describes the event's location. The backlit LCD screen illuminates on any system event or manual key press. New, 'unacknowledged' events are indicated by a flashing exclamation point (!). Once 'acknowledged,' the exclamation point changes to a check mark ('['). A system-status line shows the quantity of events presently active. The main board Supports system-status light-emitting diodes (LEDs), based upon the following conditions I events of Model FC2005: Power • Alarm Trouble Supervisory Ground-Fault I I H r I [1 I Desigo 50-Point Addressable FACP 681 3 SIEMENS Industry, Inc. Building Technologies Division Specifications - (continued) There are also LEDs to indicate when audible circuits are 'active' or 'silenced.' The main board supports four (4) system-control buttons, including: Acknowledge; Alarm Silence; Unsilence, and Reset. The system offers an off-normal warning feature, alerting users when active devices are not ready for reset. These active devices may include manual stations that have not been reset; smoke detectors with smoke remaining in the optical chamber, etc. Additionally, the main board supports an alphanumeric keypad, as well as navigation keys, which are used for scrolling maintenance functions and system configuration. The main board supports connection for up to 50 addressable devices, via one (1) 'Class A', or two (2) 'Class B' circuits. The loop supports all FDnet devices, including the Desigo Fire Safety and Model 'H'-series devices. The main board also supports one (1) 'Class A' or two (2) 'Class B' NACs. Each NAC supports a maximum 2.5 Amps - with 2.5 Amps, max., allowed between both NACs. Each NAC can be set to a synchronized strobe, for horn-strobe devices, or for audible devices. Audible devices can be set for: 'STEADY' 'ANSI Temporal 3' 'March Time 30 / 60 /120 Codes' The main board supports four (4) 'Form C relays for Alarm, Trouble, Supervisory and user-programmable events. Each relay is rated at 2 Amps at 30VDC maximum, resistive. The main board supports two (2) auxiliary 24VDC connections. Upon system reset, one (1) connection interrupts the power for five seconds for use with (4) four-wire conventional detectors. Each auxiliary-power output is 24VDC, nominal - rated at 0.75 Amps. The main board contains a built-in DACT (Model FCA201 5-Ui), which provides communication between Model FC2005 and with the central or remote monitoring station. The built-in DACT supports two (2) separate programmable accounts, as well as two (2) connections to the public-switched telephone network. The connections support RJ31 X male connectors. (For compatibility with each Model FC2005 FAcP, see the Central Station Receiver Compatibility Table on the last page of this data-sheet document.) The main board contains a battery-charging circuit, providing connection to lead-acid batteries rated at 24VDC, nominal. The main board can charge up to 1 8AH batteries. SIEMENS Industry, Inc. Building Technologies Division The main board contains a universal serial bus (USB) connector that supports connection for system configuration and module firmware upload, via the custom-configuration tool. Model FC2005 can be configured using the custom- configuration tool or manually from the alphanumeric keypad on the main board. An auto- configuration feature creates a basic system configuration of all connected devices to accelerate initial system commissioning. 50-Point Power Supply The Model FCM901 -U2 main board also supports connection to the system power supply. The 6.5 Amps (170-Watt) power supply, Model FP201 1-U1, incorporates a 4.OA, non-resettable slow-blow fuse on the primary input. It also includes a built-in AC- line filter for surge and noise suppression. Model FP201 1-U1 mounts in a standard Siemens - Fire Safety enclosure, and there are no serviceable Siemens - Fire Safety parts to be maintained. 50-Point System Enclosure The Model FH901-U2 I R2 enclosure for the Model FC2005 FACP is available in either black or red, and supports all system modules. The enclosure also supports 1 2A batteries. The Model FH901-U2 I R2 enclosure for the 50-point panel is comprised of a dual-mounting setup that allows the main board to be partially mounted in a lower-to-upper position. When temporarily installed in the lower position, technicians are allowed more space to install field wiring at the time of system set- up. When field-wiring installation is complete, the main board shall be moved to the upper position for standard mounting prior to applying power to the system. Additionally, the enclosure supports an optional battery bracket (Model FHA901 -Ui) that can be used to secure batteries up to 1 2AH. Model FHA901 -Ui is required to comply with seismic certification, pursuant to ASC I SET 7-05, Section 13.2.2. A flush-mount trim kit (Model FHA902-U1 I Ri) is also available for use when flush mounting Model FH901 - U21R2. fl 1 1 I I I I I 1 j I I I I [1 I Note: For systems requiring larger than 12AH batteries, use a ®UL Listed battery box. 11 Specifications - (continued) Optional Accessories The Model FC2005 FACP has the capability of operating an optional leased-line, city-tie module (Model FC12020-1.11) that provides a local-energy output for municipal call-box connection. The leased- line, city-tie module is installed on the back of the Model FC2005 FACP's main board, and all field wiring is connected to the main board. Model FC2005 contains a built-in RS-485 connection on the main board, thus eliminating the need for an additional communication module. The fire-system displays (FSD901 -U2 I R2) are remote LED I LCD units that show the existing status of the Model FC2005 FACP. The Model FSD901 -U2 I R2 optional display supports the following LEDs for system-status conditions: Power Alarm Trouble Supervisory Ground-Fault There are also LEDs to indicate when audible circuits are 'active'or'silenced.' The main board supports four (4) system-control buttons, including: Acknowledge; Alarm Silence; Unsilence, and Reset. For Model F5D901 -U2 / R2, a LED will illuminate for any given Alarm, Supervisory and Trouble Desigo- system event. A 3.5-inch (8.9 centimeters) by 1.5" (3.8 centimeters) LCD screen will give details of the event in alphanumeric form. The display screen can be scrolled to reveal additional events. Optional remote-system-control capabilities are also available. The Remote Peripheral Module (FCA2018-U1) provides a means of connecting a Model FC2005 Desigo FACP to a parallel printer for creating a hard copy of system-status events. This supervised, intelligent module contains built-in transient protection and plain-decimal addressing. When Model PAL-1 is used with the remote peripheral module, Model FCA201 8-U1 supervises the printer for On I Off Line, Power On, Paper Out, PaperJam, and wiring-fault conditions, as required by UL for NFPA 72 proprietary systems. The dimensions (based upon connection to a one- height-unit enclosure) for Model FC2005 are as follows: Approximate size: 16.25"(41.3 cm.) [H]; 18" (46 cm.) [W]; 5" (41.3 cm.) [D] The weight (without operating unit or batteries) is approximately 9 Lbs [4082 g]. SIEMENS Industry, Inc. Building Technologies Division Temperature and Humidity Range Model FC2005 is &UL 864 9th Edition Listed for indoor dry locations within a temperature range of i 20+/-3°F (49+/-2°C) to 32+/-3'F (0+/-2°C) and a relative humidity of 9342% at a temperature of 90+/-3°F (32+/-2°C). Related Documentation Product Data Sheet Number Model FP2011-U1 Power Supply 6806 Leased-Line / city-Tie Module 6810 Remote Peripheral Module 6811 50-Point Remote Annunciator 6817 Details for Ordering Model Part Description Number FcM901-u2 S54433-B100-A1 Desigo Main Board {for the 50-point FACP} FH901-U2 554433-B103-A1 System Enclosure, Black {for the 50-point FACP} FH901-R2 S54433-B103-A2 System Enclosure, Red {for the 50-point FACP} FP2011-u1 500-450222 170-Watt Power Supply Optional Accessories Model Part Number Description FcA201 8-Ui 554400-A65-A1 Remote Peripheral Module FC12020-U1 554400-A57-A1 Leased-Line I city-Tie Module FHA901-U1 S54433-B107-A1 Battery Bracket FHA902-U1 554433-B106-A1 Flush-Mount Trim Kit, Black FHA902-R1 554433-B106-A2 Flush-Mount Trim Kit, Red FSD901-U2 S54433-Cl 02-A4 System Display, Black {for the 50-point FACP} F5D901-R2 554433-C102-A3 System Display, Red {for the 50-point FACP} Electronics Package Model Part Number Description Desigo Fire Safety Kit for the 50-Point Addressable FACP 170W power supply, Model FP2011-U1 FC2005-U2 S54433-C103-Al (Qty. 1) Includes: System main board, Model FCM901-U2 (Qty. 1) I I i I F I I I I I I I I I I I J, [ii 1 1 I Central Station Receiver Compatibility Table The following table shows a list of central station receivers that are compatible with the Desigo Fire Safety 50-point addressable system, Model FC2005 - o o I- - - V) E Co o °E E C M uo u0 Protocol c LL w vO o' use— o' - VCA 1 SIA8 SIA2O I I I ( I I I Ademco Contact lD 4/2 1 I 1 1 3/1 1 I 1 1 Note: Multiple central station receivers are compatible with the Desigo Fire safety 50-point FACP, Model FC2005. Although the table above illustrates central station receivers that have been verified by Siemens with the Model FC2005 FAcP, additional receivers and formats can also be used with each 50-point addressable system. After completing the installation, communication between the Dig tal Alarm Communication Transmitter (Model DACT) and Central Station Receiver must be tested and verified. Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire safety Fire Safety 1 8 Fernwood Road 1577 North Service Road SIEMENS Industry, Inc. Florham Park, NJ 07932 East Oakville, Ontario February 2015 Building Technologies Division Tel: (973) 593-2600 lsll-F5l L6H 0H6 1 Canada Saperaede sheet dated 5/14 FAX: (908) 547-6877 Printed inU.SA. Tel: [905] 465-8000 URL: www.USA.Siemens.com/Desicio-Fire-Safety URL: www.Siemens.CA TELGUARD I CELLULAR ALARM TG=7FS C 0 M M U N I C A T 0 R P/N: TG7GFS04 FOR 3G/4G NETWORKS COMMERCIAL FIRE PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self-tests. Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated Iandline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. TG=7FS CELLULAR ALARM COMMUNICATOR FOR 3G/4G NETWORKS TELGUARD P/N: TG7GFS04 n,PeI - 7FS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems For the most current product specifications and UL Listings visit www.Telguard.com. TI NFPX C;]ELECTRONIC LISTED INTERNATIONAL Telguard, a Division of Telular Corporation • Cumberland Center IV • 3225 Cumberland Blvd • Suite 300 Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright ©2012 Telular Corporation • All Rights Reserved Model Part Number Description BT-33 175-387141 7-Amp-Hour Battery Set BT-34 175-387140 10-Amp-Hour Battery Set BP-61 175-387194 15-Amp-Hour Battery Set BTX-1 175-083897 31-Amp-Hour Battery Set BTX-2 175-083898 55-Amp-Hour Battery Set BTX-3 599-034220 100-Amp-Hour Battery Set Notes: The amp-hours stated above are minimum ratings. The actual batteries installed may exceed the indicated rating. SXL® is listed with BT-33, BT-34 and BP-61 only. SIEMENS Data Sheet Fire Safety Products Accessories System Battery Sets Models 13P-61; BT-series and BTX-series ARCHITECT AND ENGINEER SPECIFICATIONS I I E 24 VDC, nominal for ancillary power of fire Ivm control panels (FACPs) I 7AH, 10AH, 15AH, 31AH, 55AH & 100AH (Amp-hour) battery sets Sealed, lead-acid and rechargeable types Mounts in a system enclosure, or in Models 1313-55, BB-55R battery boxes Detector-component compatibility Product Overview Details for Ordering I Siemens - Fire Safety battery sets are manufactured by major suppliers of batteries, such as: Werker, Johnson Controls, Yuasa I Batteries, Inc. and EaglePicher Technologies, LLC. As the manufacturers improve the design of I their batteries, the amp-hour rating will increase. However, the dimensions of the batteries will remain the same to ensure I proper fit in the system enclosures, as specified. I If the system enclosure does not house the required battery set, use the Model BB-55 battery box: [data-sheet number, 3326.] Model BB-55 can house any of the available battery sets. LI System Battery Sets 3361 SIEMENS Industry, Inc. Building Technologies Division Dimensions BT-33 (2 per ) (+) BT-34 W (4 per Set) r n 12V7AH 11 : i.[ H-----•-----'1 H_-2.56 --e] -----5.95 "------' (+) BP-61 (1pi) 24V15AH 27.5 Lbs. H---------------- 13.42"------------------.. BTX-1 (+) (—) I2V3IAH 26.5 Lbs. BTX-2 (-I.) (_) (Lp!iit) I2VSSAH 40 Lbs. H--------- 7.78-- ----------..] ----------- 10.26!L----------H BTX-3 (+) r "I T I2VIOOAII 48 Lbs. 12Et-------------------- Notice: This marketing data sheet is not intended to be used for system design or nstallation purposes. For the most up-to-date information, refer to each product's installation instructions. I 1 Fire Safety 8 Fernwood Road SIEMENS Industry, Inc. Florham Park, Ni 07932 November 2014 Supersedes sheet dated 6/2012 Building Technologies Division Tel: (973) 593-2600 (511-FS) (Rev. 3) FAX: (908) 547-6877 Printed inU.S.A. URL: www.usa.5iemens.com/Fire ®UL8649th Edition Listed; FM, CSFM and NYC Fire Department Approved Each Model FSD901-U2 I R2 Remote Annunciator supports the following LEDs for system-status conditions: Power; Alarm; Trouble; Supervisory, and Ground-Fault. Note: Each remote annunciator can have its own 'Normal' system message. Further, Model FSD901-U2 I R2 can be configured to display any aforesaid system command, or any combination of FACP events. There are also LEDs to indicate when audible circuits are 'active' or 'silenced.' Each remote annunciator supports four (4) system-control buttons, including: 'Acknowledge'; 'Alarm Silence'; 'Unsilence', and 'Reset'. The dimensions for each Model FSD901- U2 I R2 remote annunciator are as follows: Approximate size: 8.5" (21.6 cm.) [H]; 11.25" (28.8 cm.) [W]; 2.5" (6.4 cm.) [D] Note: Up to eight (8) remote annunciators are supported for each 50-point addressable FACP. The weight of each remote annunciator is approximately Lbs [1814g.]. SIEMENS Data Sheet Fire Safety & Security Products DesigoTM Fire Safety System Remote Annunciator for the 50-Point Addressable System Model FSD901-U2, FSD901-R2 ARCHITECT AND ENGINEER SPECIFICATIONS Displays the existing status of the 50-point addressable fire alarm control panel (FACP) I I I I I Li Li I I Liquid-crystal display (LCD) screen shows the same event message display as the main FACP display Includes light-emitting diodes (LEDs) for system status Supports 'Acknowledge'; 'Alarm Silence'; 'Unsilence,' and 'Reset' controls Keyswitch prevents unauthorized access I Product Overview The Desigo Fire Safety Model FSD901-U2 / R2 are I separate LED / LCD remote annunciators that show the existing status of the 50-point addressable FACP (Model FC2005). Each remote annunciator I connects to the Desigo 50-point FACP through a built-in RS-485 connection on the main board. A 3.5-inch (8.9 centimeters) by 1.5" (3.8 I centimeters) LCD screen will give details of the event in alphanumeric form. The display screen can be scrolled to reveal additional events. Each I screen supports 182 characters: seven (7) lines with 26 characters per line. Optional remote-system-control capabilities are also I available. A keyswitch is also provided to prevent unauthorized access to the control operations. Additionally, Model FSD901-U2 I R2 contains navigation keys that are used for scrolling through the list of FACP events. The programming software is held in flash electrically erasable programmable read-only memory (EEPROM). Each remote annunciator is FM (43010); FDNY (46104) and CSFM (171650067:0259) Approved. SIEMENS Industry, Inc. Building Technologies Division I I I I Remote Annunciator for the 50-Point Fire Alarm Control Panel 6817 Temperature and Humidity Range Each Model FSD901-U2 I R2 Remote Annunciator is UL 864 91h Edition Listed for indoor dry locations within a temperature range of 1 20+/-3°F (49+/-2°C) to 32+/-3'F (0+/-2°C) and a relative humidity of 93+/-2% at a temperature of 90+/-3°F (32+/-2°C). Related Documentation Product Data Sheet Number - Desigo Fire Safety 50-point 6813 Addressable System Details for Ordering Model Part Description Number Number FSD901 -R2 S54433-C102-A3 Remote Annunciator, Red {for the 50-point addressable system} FSD9O1 -02 S54433-C102-A4 Remote Annunciator, Black {for the 50-point addressable system} Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 (sll-Fs) L6T 5E4 / Canada June 2013 FA)(: (908) 547-6877 Printed in U.S.A. Tel: (905) 7999937 Supersedes sheet dated 2/13 (Rev. 3) URL: www.usa.Siemens.comfFire FAX: (905) 799-9858 A L A R D 0 C U E I .s 4SPACEAGE ELECTRONlCS, INC. Specifications: I The Drawing Storage Box (DSB) shall be UL listed, constructed of 18 gauge cold rolled steel (CRS), it shall I be painted with a durable red powder coat paint. Over all dimensions 37" tall 5 1/2 wide and 4 ¼" deep. The access door shall be lettered on 2 angled sides of the cabinet providing 180 degrees of viewing. "FIRE ALARM DOCUMENTS" in White indelible letters minimum of 1" in height. The door shall have a stainless steel continuous piano hinge. The doorofthe DSB shall be locked with a I I keyed lock %" barrel. Inside the cabinet shall have a strap to secure drawing in cabinet that is adjustable for size of rolled drawings. Location to hold keys and secure emergency contact information safely inside cabinet for easy access. I El [1 I Ordering Information: I Part # Description i SSU00625 Drawing Storage Box (DSB) R E J Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free I 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! 51/2", This document is subject to change without notice, see doe # ED0479 for legal disclaimer ED0572 LT10597 Rev.B 2/2 .m-Business card slots 4-Velcro strap 4- Tab for hanging keys or USB drives Standard Features: Dimensions: 37" tall x 5 1/2 x 4 14 deep Durable 18 gauge steel construction Continuous stainless steel hinge DSB ACE-12 DRAWING STORAGE BOX The DSB (Drawing Storage Box) is an ideal solution to safely secure your critical building emergency plans such as evacuation and building layout drawings. In the event of an emergency, you are assured that responders will have immediate access to the proper drawings and information required. A critical and responsible component to any EOP (Emergency Operation Plan). The DSB (Drawing Storage Box) is engineered using 18 gauge cold rolled steel and coated with a durable RED epoxy powder coat finish. A full length stainless steel hinge provides a long lasting durable construction. One inch tall lettering silk-screened with permanent white indelible ink on 2 sides provides a full 180 degrees of viewing for immediate identification to emergency responders. The DSB (Drawing Storage Box) securely holds up to a 4" diameter 36" tall Architectural roll of drawings. With an industry standard key lock, the cabinet provides secure storage from improper access or removal of critical documentation. An additional retainer inside the box holds drawings securely upon opening the door. This cabinet also allows space to store other critical disks, USB drives, keys and contact information for the system. I I SIGNALING LISTED I I 1 I I [1 I I I I 1 Color red, powder coat texture finish 1" white indelible lettering Standard key lock to secure documents Hold a 4" dia 36" long roll of drawings Storage locations for digital media, keys and contacts [7~] Rj1 611 ED >ly 1 c: Inc. 0.486.1723 Toll Free OMOANY NUMMER Made ln '. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 ED0572 LT10597 Rev.B 1/2 No Excuses, Just Solutions! I I I I I I I I I 1 [Li I [INITIATING DEVICES] I Eli I I I I I I I I Fi SIEMENS Data Sheet Fire Safety Products Intelligent Detection Devices Intelligent FirePrintTM Multi-Criteria Detector [For use with FireFinder® XLS and FS-250 Panels] Model HFP-1 I ARCHITECT AND ENGINEER SPECIFICATIONS Most sophisticated 'detector intelligence' available Easily programmed to match specific hazard profiles from the fire alarm control panel (FACP) FirePrintTM technology to differentiate between deceptive phenomena and an actual fire Supports software-based automatic environmental compensation -_- System logic activation based on any of three (3) inputs from the detector (smoke, heat or neural network) Remote sensitivity-measurement capability Pre-alarm reporting based on fire-profile selection Polarity insensitive utilizing Sure Wirem technology 0 Multi-color detector status light-emitting diode (LED) Compatible with Model DPU (device programmer I tester unit) Field-cleanable chamber with replaceable chamber parts available 'c Multi-criteria fire detection for the price of a photoelectric detector Optional fully programmable relay base, audible base and duct housing Detectors are self-testing: complete diagnostics every four seconds • ®UL and @ULC Listed; Two-wire operation FM, CSFM & NYC Fire Department Approved I I I ii I I 1 I I I I I Product Overview Model HFP-1 1 utilizes advanced detection technology that allows each detector to distinguish non- threatening deceptive phenomena -such as cigarette smoke, from actual fire hazards, while optimizing detection for the area it is intended to detect. Model HFP-1 1 uses state-of-the-art microprocessor circuitry with error check, detector self-diagnostics and supervision programs. Model HFP-1 1 is compatible with the Siemens - Fire Safety field device program I test unit (Model DPU), which is a compact, portable, menu-driven accessory for electronically programming and testing detectors, easily and reliably. Model DPU eliminates the need for cumbersome, unreliable mechanical programming methods—such as dials or switches, and reduces installation and service costs by electronically programming and testing the detector prior to installation. Model HFP-1 1 is compatible with FS-250 and Fire Finder XLS FACP5. I I I Specifications Model HFP-11 is plug-in, two-wire and multi-sensor detector (with both photoelectric and thermal inputs) that is compatible with FireFinder XLS and FS-250 series of FACPs. Each detector consists of a dust-resistant, field-cleanable and photoelectric chamber; a solid state, non-mechanical thermal sensor, and microprocessor-based electronics with a low-profile plastic housing. Model HFP-1 1 utilizes state-of-the-art ASIC circuitry and surface-mount technology for maximum reliability. Every Model HFP-1 1 fire detector is shipped with a protective dust cover. Model HFP-1 1 utilizes an infrared light emitting diode (IRLED), and light-sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern. Model HFP-1 us ®U nderwriters' Laboratory and Underwriters' Laboratory of Canada Listed. El SIEMENS Industry, Inc. FirePrintTM Multi-Criteria Detector 6301 Building Technologies Division I Specifications - (continued) The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non-smoke, airborne contaminants in such a way as to maintain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles, and is received by the photodiode. Model HFP-1 1 also utilizes a modern, accurate and shock-resistant thermistor to sense temperature changes. The 'on-board' FirePrint- technology allows the detector to first gather smoke and thermal data, and then analyze this information in the detector's 'neural network.' By comparing data received with the common characteristics of fires or fire fingerprints, Model HFP-1 1 can compare these 'fire prints' to those of deceptive phenomena that cause other detectors to false alarm. FirePrint The advanced FirePrint technology allows Model HFP-1 1 to accurately determine a true fire hazard from unthreatening, deceptive phenomena. Further, the advanced FirePrint technology will not require a need to use alarm-delaying verification and confirmation techniques, which can increase the probability of losses due to fire. Model HFP-1 1 provides the highest level of detector intelligence available today with a detector! control panel link that allows the user to program the detector for the specific hazard profile, using a simple software menu selection. Model HFP-1 l's FirePrint application monitors input from both the photo chamber and the thermal sensor, evaluating this information with sophisticated mathematical formulas or algorithms, comparing This input to characteristics of both threatening fires and deceptive phenomena that would mislead any ordinary detector. Detectors are optimized by selecting one (1) of the following 11 applications: Office! Retail Lobby Computer room Dormitory Healthcare Parking garage Utility! Transformer room Hostile environment Precious storage Air Duct Warehouse! Light Manufacturing The control panel programs Model HFP-1 1 detector for the protected area without hassle and without confirmation delays. Once optimized for the hazards in the protected area, Model HFP-1 1 provides the best detection. Should the operator or installer forget to program the detector, Model HFP-1 1 will revert to a default setting, allowing operation as an office-environment detector. SIEMENS Industry, Inc. Building Technologies Division The FirePrint technology was developed over years of research and reviewing the results of over 20 years of fire test data in one of the world's most advanced fire-research centers. The results of this research are the mathematical models that form the algorithms used in FirePrint. No other fire detector has this level of intelligence or this amount of research and development supporting its design. The microprocessor's software can identify and disregard false input caused by radio frequency (RFI) and electromagnetic (EMI) interference, while validating all Trouble conditions before annunciating or reporting to the FACP. Model HFP-11 The Model HFP-1 1 detector's microprocessor uses an essential electronically erasable programmable read-only memory (EEPROM) to store the detector's address and other critical operating parameters, including the assigned program values for Alarm and Trouble thresholds. Communication within the detector, as well as between Model HFP-1 1 and the control panel, or with Model DPU (field device programmer! test unit), are supervised and safe-guarded against disruption by reliable, microprocessor-based error checking routines. Additionally, the micro-processor supervises all EEPROM memory locations, and provides a high degree of EEPROM- failure fault tolerance. Model HFP-1 1 determines its operating status to be Normal in Alarm or in Trouble modes, depending on the difference between the alarm threshold values stored in the detector's memory and the detector's latest analog measurement The detector then communicates changes in its status to the control panel. In addition, the FireFinder XLS control panel will sample the value of the analog signal for Model HFP-1 1 over a period of time, in order to determine if those values indicate excessive buildup in the photo chamber. If such is the case, the FireFinder XLS control panel will indicate the particular detector requires maintenance. Model HFP-1 1 is listed as a self-testing device. The visible light emitting diode (LED) for Model HFP-11 flashes green every four (4) seconds to indicate it is communicating with the control panel, as well as to indicate it has passed its internal self-test Should the detector sense a fault or failure within its systems, the LED will flash amber, and the detector will transmit that data to the control panel. A quick visual inspection is enough to indicate the condition of the detector at anytime. If more detailed information is required, a printed report can be provided from the FireFinder XLS FACP, indicating the status and settings assigned to each individual detector. When Model HFP-11 moves to the Alarm mode, it will flash red, and will continue flashing until the system is reset at the FACP. Simultaneously, any user-defined, system-alarm functions programmed into the system are activated. I I LI Specifications - (continued) Detector sensitivity, calibration and identification are dynamically supervised at the respective FACP. Detector sensitivity and pre-alarm levels are a function of the application chosen at the control panel, and are controlled by the panel. If an alternate, non-FirePrint mode is selected, then the sensitivity can be changed from the control panel. All Model HFP-1 1 detectors use a surface mounting base, Model DB-1 1, which mounts on a 4-inch octagonal, square or single gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self-wiping contacts for increased reliability. Model DB-1 1 can be used with the optional Model LK-1 1 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-1 1 has integral decorative plugs to cover the outer mounting screw holes. Model HFP-1 1 may be installed on the same initiating circuit with Model HMS-series manual stations; Model HTRI-series interfaces; Model HCP output-control devices, or Model HZM series of addressable, conventional zone modules. All Model HFP-1 1 detectors can be cleaned in the field - when required -via easily removing the detector cover and unsnapping the photo chamber. There is also the option of cleaning the interior of the detector with a clean, soft cloth or brush - or by replacing the labyrinth and bug screen included in the detector maintenance kit, Model DMK-11. All Model HFP-1 1 detectors are approved for operation within the ®UL-specified temperature range of 32 to 100°F (0 to 380C). Model DPU The Device Program I Test Unit accessory is used to program and verify the address of the detector. The technician selects the accessory's program mode, and enters the desired address. Model DPU automatically sets and verifies the address and tests the detector. Model DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment from practically any location. When in 'test' mode, Model DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. Application Data Installation of the Model HFP-1 1 series of fire detectors requires a two-wire circuit. In many retrofit cases, existing wiring may be used. '1-tapping' is permitted only for Style 4 (Class B) wiring. Model HFP-1 1 is polarity insensitive, which can greatly reduce installation and debugging time. Model HFP-1 1 fire detectors can be applied within the maximum 30 foot center spacing (900 sq. ft. areas,) as referenced in NFPA 72. This application guideline is based on ideal conditions, specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire-protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens -Fire Safety distributor or sales office whenever you need assistance applying FirePrint in unusual applications. Be sure to follow NFPA guidelines and ®UL Listed / €ULC Listed installation instructions -included with every Siemens - Fire Safety detector -and local codes as for all fire protection equipment. Technical Data Operating Temperatures: +32°F (0°C) to 100°F (38°C), per ®UL 268 / 268A Relative Humidity: 0-93% Non-condensing Maximum Spacing: 30-foot Centers (900 Square Feet), per NFPA 72 Chapter 5 and ULC-S524 Current Draw: 1 mA in Alarm or Supervisory mode I I I I I I I I I d L] I SIEMENS Industry, Inc. Building Technologies Division Mnijnfinn flirirm Details for Ordering Pa rt Model Number Description HFP-1 1 500-033290 FirePrint Multi-Criteria Fire Detector DB-1 1 500-094151 Detector Mounting Base for Series 11 DB-1 1 E 500-094151 E Detector Base {small} AD2-P 500-649706 Air-Duct Housing AD2-XHR 500-649708 Air-Duct Housing {with relay) DB-HR 500-033220 Relay Base for H-Series Intelligent Detectors ADBH-1 1 500-033210 Audible Base RL-HC 500-033230 Remote Alarm Indicator: 4" octagon-box mount, red RL-HW 500-033310 Remote Alarm Indicator: Single-gang box mount, red LK-1 1 500-695350 Base Locking Kit for Series 11 Detectors Series 11 Maintenance Kit DMK-1 1 500-695338 {replacement labyrinth and bug screen) In Canada, order Model Part Description Number DB-1 1 C 500-095687 Detector Mounting Base for Series 11 Detectors (®ULC) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 lsll-Fsl L6T5E4/Canada June 2015 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 7999937 Supersedes sheet dated 9/13 (Rev. 5) URL: www.usa.Siemens.com/Fire FAX: (905) 799-9858 SIEMENS Data Sheet Fire Safety Products Intelligent Initiating Devices HMS-Series Models HMS-D, HMS-S LI I I I ARCHITECT AND ENGINEER SPECIFICATIONS Durable design Shock-a nd-vib ration resistant I Pull-down lever is down, until manually reset Reset with Allen Key No break rods necessary Custom microcomputer-chip technology Dynamic supervision to the fire-alarm control panel (FACP) Polarity insensitive via Sure WireTM technology Two-wire operation Surface or semi-flush installation Model DPU programs and verifies address and tests functionality of each device Electronic-address programming is easier, more efficient and more dependable Comes in single-action (Model HMS-S) and double-action (Model HMS-D) stations Product Overview The Siemens intelligent manual fire-alarm boxes (Models HMS-S and HMS-D) provide the most advanced method of address programming and supervision. Each Model HMS-series manual box achieves the state of an 'intelligent-initiating device' by incorporating custom microcomputer-chip technology with sophisticated, bi-directional communication capabilities with the FACP. Specifications Models HMS-S and HMS-D are constructed of durable, molded polycarbonate material that is matte finished in red with raised white lettering. The housing accommodates a 'pull-down' lever, which - when operated -locks into position; indicating the manual fire-alarm box has been activated. The pull down lever remains down I in the 'locked' position, until the fire-alarm box is manually reset. The manual fire alarm box can only be reset by opening the hinged housing cover with an Allen key; followed by closing and locking the cover. ®UL Listed; FM (#3015946 & 3052621), CSFM ('7150-0067:0036) & NYC Fire Dept. (420212E, Vol. 1) Approved Models H MS-S and HMS-D operate with Siemens - Fire Safety FACPs. The microcomputer chip to the manual fire-alarm box has the capacity of storing - in memory - identification information as well as important operating-status data. Innovative technology from Siemens - Fire Safety also allows all Model HMS-series intelligent manual fire-alarm boxes to be programmed via the Device Programmer I Test Unit (Model DPU). Model DPU is a compact, portable and menu-driven accessory that makes programming and testing of a manual fire- alarm box device faster, easier and more dependable than previous methods. The programmer I tester eliminates the need for mechanical-addressing mechanisms of a device because Model DPU electronically sets the address of the manual fire-alarm box into its microcomputer chip, non-volatile memory. Hence, vibration, corrosion and other conditions that can compromise or even deteriorate mechanical-addressing mechanisms are no longer a cause for concern. r] I I L-1 I I LI I I Model HMS-D Model H MS-S Dual-Action Station Single-Action Station I [1 SIEM ENS Industry, Inc. HMS Series Intelligent Initiating Devices 6306 Building Technologies Division Specifications - (continued) Models HMS-S and HMS-D are fitted with screw terminals for connection to an addressable circuit, and can be either surface or semi-flush mounted. The Model HMS-series manual fire-alarm boxes derive their power, communicate information and receive commands over a single pair of wires. The Model HMS-series is compatible on the same circuit with all Model 'H'-series detectors, interfaces or addressable, conventional zone modules. Electrical Ratings Current Draw (Active or Standby) - 1 .4mA Details for Ordering Part Shipping Model Description Number Weight HMS-D 500-033400 Addressable Manual Fire 2.5 Lbs. l.13Oz. Alarm Box, Dual Action HMS-S 500-033200 Addressable Manual Fire 2.0 Lbs. 0.9 0z. Alarm Box, Single Action LTP 500-620490 Reset Tool Package (contains _two _(2)_tools] 0.5 Lb. 0.23 Oz. SB-5R 310-019860 Surface-Mounting Box i 1.5 Lbs. 10.7 Oz. Mounting Diagram SURFACE MOUNTING ENCLOSURE <_.> HOUSING 117 .4 In -< ulimpicnTn NAMEPLATE BACKPLATE 1 3/16 in. HOUSING BACKPLATE (.0 000 0000 I 3m. in DEEP ICH BOX SUPPLIED) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Roac 1577 North Service Road E. SIEMENS Industry, Inc. Florham Park, NJ 07932 Oakville, Ontario March 2015 Building Technologies Division Tel: (973) 593-2600 (Sll.FS) L6H 0H6 / Canada Supersedes sheet dated 912013 FAX: (908) 547-6877 Printed in U.S.A. Tel: [905] 465-8000 (Rev. 5) URL: www.usa.Siemens.com/Fire URL: www.5iemens.CA I L Ll I I I I [INTELLIGENT MODULES] I I I I I I Ti Li I I SIEMENS Data Sheet Fire Safety Products HTRI-Series Interface Modules Models HTRI-D, HTRI-R and HTRI-S ARCHITECT AND ENGINEER SPECIFICATIONS I Interfacing and supervising normally open (N.0) or normally closed (N.C) contacts Integral single-pole, double-throw (SPDT) relay on Model HTRI-R (up to 4 amps) Dual input on Model HTRI-D, using a single address Polarity insensitive with Sure WireTM technology Dynamic supervision Two-wire operation Multi-color light-emitting diode (LED) indicates system status: GREEN/AMBER/RED Mounts in a 4-inch (10.2 cm.) square, 2_1/4" (5.7 cm.)—deep single-gang or double-gang back box Easy front access to programming port and wiring terminals Comes with 5"-x- 5" (12.7 -x-- 12.7 cm.) faceplate 10. I I I I / Electronic address programming is easy and dependable Device Programmer/ Tester programs and verifies address • ®UL Listed & @ULC Listed; of the device and tests for proper functionality FM, CSFM and NYC Fire Dept. Approved I LI I I I Product Overview The Siemens - Fire Safety HTRJ-series Intelligent interface modules are designed to provide the means of interfacing direct shorting devices to the fire-alarm control panel (FACP) loop circuit. The HTRI-series modules provide the most advanced method of address programming and supervision on the market — combined with sophisticated control panel communication. Each HTRT-series interface module incorporates a microcomputer chip, and each interface module achieves the state of an 'intelligent device' through its microcomputer-chip technology, combined with its sophisticated, bi-directional communication capabilities with the FACP. Specifications The Siemens Mode HTRI-series intelligent interface modules are available in three (3) types: Model HTRI- D, as well as Models HTRI-S and HTRI-R, which are both designed to monitor a (N.0) or (N.C) dry contact. The interface module reports the status of the (N.0) or (N.C) contact to the control panel. Model HTRI-S can only monitor and report the status of the contact, while Model HTRI-R incorporates an addressable 'Form C' relay. The Model HTRI-R relay and contact device input are controlled at the same address. For the FACP, the relay and input contact can be controlled as a separate function. The relay is typically used where control or shunting of external equipment is required. The Model HTRI-D is a dual-input module that is designed to supervise and monitor two (2) sets of dry contacts. Model HTRI-D only requires one (1) address, but responds independently to each input. Model HTRI-D is ideal for monitoring a water-flow switch and its respective valve tamper switch. Model HTRI-D flashes twice - once for each address, and Model HTRI-R LED indicates a change of state in the relay. The device's microcomputer chip has the capacity of storing, in memory, identification information; as well as important operating-status data. LI LI LI I I I L 1 I SIEMENS Industry, Inc. HTRI Series Interface Modules 6304 Building Technologies Division Details for Ordering I LI I I I I I Specifications (continued) Each Model HTRI device has a multi-color LED that flashes GREEN when operating in Normal; AMBER if unit is in Trouble condition, and RED to indicate a change of state. Siemens - Fire Safety innovative technology allows HTRI-series intelligent interface modules to be programmed via the Device Programming I Test Unit: a compact, portable and menu-driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The programmer I tester eliminates the need for mechanical addressing mechanisms, such as: program jumpers, DIP switches or rotary dials, since Model DPU electronically sets the HTRI-series interface address into the non-volatile memory of the interface microcomputer-chip. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. The HTRI-series is fitted with screw terminals for connection to an addressable circuit, and is fully compatible on the same Siemens FACPs with Siemens Model 'H'-series intelligent detectors; Model 'HMS'-series addressable manual stations, or any other addressable intelligent modules (e.g. - Model HZM or Model HCP). Temperature and Humidity Range Model HTRI-series intelligent interface modules are ®UL Listed. Environmental operating conditions for HTRI-D, HTRI-R and HTRI-S modules are 32°F (0°C) to 1 20°F (49°C) with a relative humidity of no greater than 93%, non-condensing. Electrical Ratings Current Draw 1.3mA (Active or Standby) I Relay Ratings, Model HTRI-R 4 Amps, 125 VAC Resistive: 4Amps, 30 VDC Electrical Ratings eiay Ratings, ivioaei II i RI-K - cont. a) 3.5A, 120 VAC (0.6P.F.) 3.OA, 30 VDC (0.6P.F.) Inductive: 2.OA, 120 VAC (0.4P.F.) 2.OA, 120 VAC (0.35P.F.) 2.OA, 30 VDC (0.35P.F.) Mounting Diagram Models HTRI-S, HTRI-D and HTRI-R mount directly into a 4-inch (10.2 cm.) square, 2 1/4" (5.7 cm.)-deep box back box, or to a user-supplied double-gang back box. A 5" (12.7 cm.) square, off-white faceplate is included with each HTRI-series module. Note: For Marine installations, a faceplate (Model USCG-HPLATE) is available separately. The faceplate must be used to protect Siemens HTRI-series interface modules from receiving radio-frequency interference (RFI). Part Model Description Number HTRI-R 500-033300 Single Input Module with Relay HTRI-D 1 500-033360 Dual Input Module HTRI-S 500-033370 Single Input Module USCG- Cover metal plate for HPLATE S54319-F22-Al I HTRI Series Interface Modules* *denotes for required use with Marine-only I I I I I 11 I I I Notice: This marketing data sheet is not intended to be used for system design or installations / applications installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road SIEMENS Industry, Inc. Florham Park, NJ 07932 East Oakville, Ontario June 2015 Building Technologies Division Tel: (973) 593-2600 (Sll-FS) L6H 01-16 1 Canada supersedes sheet dated 3/2015 FAX: (908) 547-6877 Printed in U.S.A. Tel: [905] 465-8000 (Rev 4) URL: www.USA.Siemens.com/FIRE URL: www.Siemens.CA I Li I I I LI I I I I [NOTIFICATION DEVICES] Li I I [1 I I I Li I 1 I SIEMENS Data Sheet Fire Safety Products Notification Appliances_________ ZH & ZR - Strobes, Horns, & Horn I Strobes I Application: Indoor Product Overview - Strobes can be synchronized using the Siemens DSC sync modules, the Siemens 50-point, 252-point and 504-point addressable fire alarm control panels (FACPs), as well as with: FireFinder® XLS and MXL® FACPs PAD-3 or PAD-4TM NAC Extenders with built-in sync protocol - Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (Series 'ZH') - Ceiling-mount models feature field-selectable Candela settings of 1 5/30/75195cd and 11 5/1 77cd - Wall-mount models feature field-selectable Candela settings of 15/30/75/110cd and 135/1 85cd - Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted - Strobes produce one (1) flash per second - "Special Applications" listed with Siemens panels - EZ Mount Universal Mounting Plate (Model ZB Series) - uses single plate for ceiling and wall mount installations - EZ Mount design - with separate base plate— provides ability to pre-wire the base and test the circuit wiring before the walls are covered - ®UL Listed & @ULC Listed; CSFM Approved (Series 'ZH': #71250067:0248> Fire Alarm Devices For The Hearing Impaired) CSFM Approved (Series 'ZR': #71250067:0252> Fire Alarm Devices For The Hearing Impaired) - ADA / NFPA compliant Specifications General - Audible/Visual notification appliances are listed for indoor use only - Appliances are listed under ®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and ®UL Standard 464 (Fire Protective Signaling) - Appliances use a universal back plate, which allows mounting to a single-gang, double-gang, 4-inch-square (10.2 cm.), 4"-octal (10.2 cm.), or a 3-112" (8.9 cm.) octal backbox - Two-wire configurations allows capability for directly connecting appliances to the mounting back plate - Continuity check will occur for entire NAC circuit prior to attaching any audible I visual-notification appliances - A cover fits over the mounting plate for protection to dust and other outside elements Cover is easily removed when the appliance is installed over the back plate - Removal of an appliance will result in a Trouble condition by the Siemens Fire Alarm Control Panel (FACP) 'Z' Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division I I I I I I I 1 U I I 1 I I I I I I I FlJ :1 ZR Series I ZR&Z4 (for mounting) ZH Series Specifications - (continued) Strobes and Audible Strobe Combinations - Strobe appliances produce a minimum flash rate of 60 flashes per minute (one [1] flash per second) over the Regulated Input Voltage Range, and incorporate a Xenon flashtube enclosed in a rugged Lexan® lens - Strobes are available with two (2) or four (4) field-selectable settings in one (1) unit, and are rated - per ®tJL 1971 - for up to: o 15/30/75/11 Occl for wall mounted 135I185cd for wall mounted 1 513 0175195cd for ceiling mounted 11511 77c for ceiling mounted - Strobes operate over an extended temperature range of 32°F to 120°F (0°C to 490C), and be listed for maximum humidity of 95% RH - Strobe inputs are polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Siemens FACP Audible and Audible! Strobe Combinations - Horns and horn I strobes are listed for Indoor use under ®UL Standard 464 - Horns are able to produce continuous synchronized output or a Temporal Code-3 synchronized output - Horns have at least two (2) sound-level settings of 90 and 95 dBA ynchronization Modules - The strobe portion, when synchronization is required, is compatible with the Siemens DSC sync modules; the Siemens 50-point, 252-point anc 504-point addressable FACPs, as well as with: FireFinder® XLS and MXL® FACPs PAD-3 or PAD-4TM NAC Extenders with built-in sync protocol - The strobes will not drift out of synchronization at any time durirg operation - Audibles and strobes are able to synchronize on a two-wire circuit with the capability to silence the audible, if required - Strobes revert to a non-synchronized flash-rate, if the sync module or power supply should fail to operate (i.e. - contacts remain closed) - All notification appliances are listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" > Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second All candela ratings represent minimum-effective Strobe intensity, based on ®UL Standard 1971 Series ZH Strobe products are listed under ®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) Series ZH horns are listed under ®UL Standard 464 for audible signal appliEnces (Indoor use only) Mounting Diagram (Shown In Inches) SlEMENSIndustry, Inc. Building Technologies Division I I I I I I El I El I I I I I I I I P1 Li I I Mounting Diagram SCRTWS Installation With the provided pan head screws, install mounting plate to a: -. ulnglr-gang, double-gang; -4- 110.2 cm.) square, - V (15.2 cm.) octagon bacicbox Connect the field wiring. Address wires back into baCkbox, Place dust cover over mounting plate to protect the terminals while performing the wiring-continuity check. Remove dust cover before snapping or installing the appliance Onto the mounting plate Removal Kz"" igipartant: Device only has one (1) mounting orientation. Match the top of the base to the top of the device. It it is desired to further secure the device to the base, then use the two () optional screws which are provided in the shipment. To install, punch out the screw holes located at the top and bottom of the device. To remove the appliance, push a small, flat-bladed screwdriver into the side opening. The screwdriver must clear the snap release opening by 114 '( 0.54cm.), In order for the appliance's snap to disengage. )pfnt: Do not pry off the housing with the screwdriver. Apply pressure with the screw driver inserted in either side opening. I I I I I Technical Data I I ZH Horn: Wall and Ceiling Mount Operating Voltage (Special Application) Per ®UL 464 Input Voltage Low* High* DC 16.0-33.OVDC L 0.018 j 0.044 FWR 16.0 -33.0VRMSI 0.045 1 0.075 I *Current draw is the same for the Continuous Horn, Code 3 Horn, and March Time settings ZH Horn I Strobe Series: Wall Mount ZH Horn I Strobe Series: Ceiling Mount Current Ratings (AMPS) MaxIMuMRMS Current- with llLqh dBA Setting Input Voltage 15cd 30cd 75cd 110c4135cd 185cd DC 16.0-33.OVDC 0.078 0.113 0.195 0.259 0.371 0.506 FWR 1 16.0-33.OVRMS 0.141 0.200 10.302 0.406 0.521 0.722 Current Ratings (AMPs) MAXIMUM RMS Current-with Low dBA Setting Input Voltage 15cd I 30cd I 75cd I 95cd 1135cd 185cd DC I 16.0-33.OVDC 0.070 0.107 0.188 0.246 0.324 0.455 FWR 16.0 - 33.OVRMS 0.123 0.179 10.29010.39110.497 10.699 ZR Strobe Series: Wall Mount Current Ratings (AMPS) Strobe Setting - (Cd) Input Voltage Input 30cd 75cd 110cc 135cd _41 -8- DC 16.0-33.OVDC 0.064 0.098 0.175 0.233 0.318 0.445 FWR 16.0 - 33.OVRMS 0.108 0.164 10.26810.36810.482 1 0.684 ZR Strobe Series: Ceiling Mount Current Ratings (AMPs) Strobe Setting - (Cd) Input Voltage 15cd I 30cd I 75cd I 95cd 1 115cd I 177cd DC 16.0-33.OVDC 0.069 0.111 0.200 0.264 0.318 0.445 FWR 116.0-33.0VRMS 10.117 10.180 0.297 0.398 0,482 10.684 €ULC Directional Characteristics -3 dBA 35 degrees left; 40 degrees right -6 dBAJ 55 degrees left; 65 degrees right SlEMENSIndustry, Inc. Building Technologies Division Current Ratings (AMPs) MAXIMUMRMS Current- with High dBA Setting Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0-33.OVDC 0.087 0.131 0.222 0.292 0.371 0.506 FWR 16.0-33,0VRMS0.149 0.216 0.331 0.436 0.521 0.722 Current Ratings (AMPS) MAXIMUM RMS Current- with Low dBA Setting Input Voltage 15cd I 30cd I 75cd I 95cd 1 11 5cd I 177cd DC I 16.0-33.OVDC 0.075 0.121 0.213 0.277 0.324 0.455 FWR 116.0-33.OVRMS 0.131 0.195 10.31910.42110.497 10.699 ZH and ZH-MC Series: Wall and Ceiling Mount dBA Sound Output Description Volume Reverberant Per ®UL 464 16.0 VDC 24.0 VDC 33.0 VDC Continuous Horn Low 77 81 83 High 83 87 90 Code 3 Horn (or March Time)* Low 72 76 79 High 79 82 86 dBA Sound Output Description Volume Reverberant Per €DULC-5525-99 20.0 VDC 24.0 VDC 31.0 VDC Continuous Horn Low 88 90 91 High 93 95 96 Code 3 Horn (or March Tirne)*j Low 88 90 91 High 93 95 96 Available only in sync mode. I I [1 I I I I I Li Technical Data - (continued) Notes: 1. Strobes will produce 1 flash per second over the Input Voltage range. These horn/strobe models are UL Listed to operate over a Voltage Range Limit from 16.OVDC to 33.OVDC for 24VDC applications using filtered DC or unfiltered Full-Wave-Rectified (FWR) input voltage. All models are OUL Listed for indoor ceiling use with a temperature range of +00C to +49°C (+32°F to +120°F) and maximum humidity of 93%+I- 2% RH. The effect of shipping and storage temperatures will not adversely affect the performance of the appliance when stored in original cartons, and is not subjected to either misuse or improper handling of shipment. Details for Ordering - (Including Mounting Options & Agency Approvals) AytIILy ApIuvdI Model Part Number Description Mounting Options* UL ULC CSFM ZH-R 500-636159 Z Horn: Red B,D,E,F,X v' V V ZH-W 500-636160 Z Horn: White B,D,E,F,X V V V ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E,F,X V V / ZH-MC-W 500-636162 Z Horn: Multi Candela (Wall), White B,D,E,F,X V V V ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela (Wall), Red B,D,E,F,X V V V ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela (Wall), White B,D,E,F,X V V V ZH-MC-CR 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F,X V V V ZH-MC-CW 500-636166 Z Horn: Multi Candela (Ceiling), White B,D,E,F,X V V V ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling), Red B,D,E,F,X V V V ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F,X V V V ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall), Red B,D,E,F,X V V V ZR-MC-W 500-636170 Z Strobe: Multi Candela (Wall), White B,D,E,F,X V V V ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red B,D,E,F,X V V V ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White B,D,E,F,X V V v' ZR-MC-CR 500-636173 Z Strobe: Multi Candela (Ceiling), Red B,D,E,F,X V V V ZR-MC-CW 500-636174 Z Strobe: Multi Candela (Ceiling), White B,D,E,F,X V V V ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling), Red B,D,E,F,X V V V ZR-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling), White B,D,E,F,X V V V ZB-R 500-636193 Accessory — (Includes base, dust cover, mounting screws and installation sheet) ZB-W 500-636194 Accessory - (Includes base, dust cover, mounting screws and installation sheet) V = Listed I Approved * = Refer to data sheet #: 2585 for detailed mounting options I I I El I ILI [1 I I ri I I I I I I Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road SIEMENS Industry, Inc. Florham Park, NJ 07932 East Oakville, Ontario June 2015 Building Technologies Division Tel: (973) 593-2600 Sll) L6H 01-16 I Canada Supersedes sheet dated 6/2012 FAX: (908) 547-6877 Printed in U.S.A. Tel: [905] 465-8000 (Rev. 4) URL: www.usa.5iemens.com/Fire URL: www.Siemens.CA I I I I I I I I I I ii [CSFM LISTINGS] I I I Li Li I I I I I Li I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0067:0259 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 I Email: peter.pawchak@siemens.com DESIGN: Models Desigo FC2005-U2,-R2 and Cerberus Pro FC901-U3,-R3 Fire Alarm Control Units. Non-coded; local, auxiliary, remote, proprietary and central station service; automatic or I manual waterflow, and sprinkler supervisory service when used as a remote station (protected premise) unit, proprietary or central station fire receiving unit. Refer to listee's data sheet for additional detailed product description and operational considerations. I Basic components: FH901-U2; Desigo Enclosure (Black) FH901-R2; Desigo Enclosure (Red) I FH901-U3; Cerberus Pro Enclosure (Black) FH90I-R3; Cerberus Enclosure (Red) FHA901-U1; Battery Brackets, left/right FCM901.-U2; Desigo Main Board I FCM901-U3; Cerberus Main Board FC12020-U1; City Tie Board (optional) I FP20II-UI; Power Supply Unit FSD901-U2; Desigo Remote Annunciator (Black) FSD90I-R2; Desigo Remote Annunciator (Red) FSD901-U3; Cerberus Remote Annunciator (Black) I FSD901-R3; Cerberus Remote Annunciator (Red) *FDC10422; Input/Output Module RATING: 120V60hz2A I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three- pulse Temporal Pattern Fire Alarm I Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum *Rev 03-22-12 gt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 l Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0067:0259 Page 2 of 2 Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 03-22-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing shoulc not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0067:0203 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC I LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 I Email: Peter.pawchak@siemens.com DESIGN: Models FP-11, HFP-11, and *HFpO11 analog and FPO-11 photoelectric type smoke I detectors. Models FP-1, and HFP-11 also have a supplemental 1350F heat sensor. Model DGH-11 detector guard housing suitable for use with Models HFP-11, *HFpO11 and FP-11 smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in a manner acceptable to the authority having jurisdiction. These detectors are intended for installation on a vertical wall surface or the ceiling. They are also acceptable for duct application with an air velocity of 0-4000 ft/mm. when used with Models DB- 11, DB-HR or I DB-X11RS bases. MARKING: Listees name, model number, and UL label. I APPROVAL: Listed as photoelectric type smoke detectors for use with listee's separately listed base Model DB-11, DB-HR or DB-X11RS (CSFM Listing No. 7300-0067:134) and separately listed compatible fire alarm control units. Model DGH-11 detector guard housing is listed for use only with FP-11 and HFP-11. Refer to listee's Installation Instruction Manual for details. NOTE: Li I I I *Rev. 09-27-2004 [iii This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION .. .. OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0067:0134 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models DB4T, DB4TS, DB4F, DB4TF, DB4FS, DB3S, ADB3, ADBX3, DB-HR, *DB2HR DBX3RS, DB-11, DB-X11RS. ADBI60, ADB-11, ADBH-11,SBGA-34, ADBX-11 and 8837 detector bases and Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3 auxiliary relays. Model DB-11 is suitable for use only with Model RR-11 or RR-11F auxiliary relay. Models DB-11 base, ADBH-11 audible base, and DB-HR, *DB2..HR relay bases are intended to be used with Models HFP-11, *HFPO11 and HFPT-11 Intelligent Series smoke and heat detectors (CSFM Listing No. 7272-0067:0223 and 7270-0067:0224). Model SBGA-34 audible base is intended to be used with Models HFP-11, HFPT-11, or HFPO-11 detectors (CSFM Listing No. 7272-0067:0223 and 7270-0067:0224), Models FDOT421, FD042I, 0H921 and 0P921 detectors (CSFM Listing No.7272-0067:0258), Models FDT421 and H1921 detectors (CSFM Listing No.7270-0067:0262), and Models FDOOT441, FDOOTC441, OOHC941 and 00H941 detectors (CSFM Listing No.7270-0067:0260). *Model DB2-HR Relay Base can be used also with Intelligent Series smoke detectors type FDOT42I, FD042I, 0H921, 0P921 (CSFM Listing No.7272-0067:0258), FDT42I, H1921(CSFM Listing No.7270-0067:0262), and FDOOT441, FDOOTC441, 00HC941, 0OH94I(CSFM Listing No.7270-0067:0260). Refer to listees data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model DB- 11, ADBH-11, SBGA-34, DB-HR and *DB2HR maybe installed on the ceiling or on the wall. MARKING: Listees name or SIEMENS, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and fire alarm control units. I I *Rev. 04-15-14gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I I I I I Li Li I I I I El I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 7150-0067:0036 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 I Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models MS-5, -51, -52, -52C, -53 through -57, -60, -60DAP, -60DP, -60KS, -151, -157, -500 I through -507, -511, -512, -512C, -513, -513C, -514, -514C, -515, -516, -517, -517C, -518, and MS-MI; MH-51, -57, -501, -507, -511, -517, -517C, -518; MSX-1, -2, -2D, -100; MHX-1, -100; MSl-1, -2, -10, -lOB, -20,-20B, -60, -6ODA; MSl-MB6; HMS-S, -0, -M noncoded manual pull I stations. Single action, double action, and double action distinct type. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed electrically compatible fire alarm I control units. Models with prefix MH are suitable for use with Halon extinguishing system. Models HMS-S, -D, -M are addressable. * The following manual pull boxes meet the requirements of UL Standard 38, 1999 Edition I and California amendments: Models MS-151, -157, -501; MSI-10B, MSI-20B and HMS-S, -D, -M. I I I l~~ I *Rev 03-25-14 gt I r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 l Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing Expires June 30, 2016 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0067:0242 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Siemens Industry, Inc. Buildirg Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Control Unit Accessories. Refer to listee's data sheet for detailed product description and operational considerations. Accessories are listed as follows: HTRI-S, -D, -R Addressable Switch Interface Module HTRI-M Addressable Interface Module HUM Loop Isolator Module HZM Conventional Zone Loop ILED-HC, -HW Remote Lamps RATING: INSTALLATION: MARKING: APPROVAL NOTE In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, and UL label. Listed as control unit accessories for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 11-04-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0252 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor use on walls. Models ST-MC-CW, ST-HMC-CW, ZR-MC-CR, ZR-MC-CW, ZR-HMC-CR, and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating considerations. RATING: Electrical 16-33VDC/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, 110cd ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW 15cd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd ZR-HMC-CR, ZR-HMC-CW 115/177cd Flash Rate: 60 flashes I minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & I ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -Ware wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical I candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. NOTE: I I 9-1 O-2007mt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify -correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I LI I I Li I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0248 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models NH-R, NH-W, NH-CR, NH-CW, ZH-R, and ZH-W horns and models NS-MC-R, NS-MC-W, ZH-MC-R, ZH-MC-W, ZH-HMC-R, AND ZH-HMC-W Horns / Strobes. Models NS-MC-CR, NS-MC-CW, NS-HMC-CR, NS-HMC-CW, ZH-MC-CR, ZH-MC-CW, ZH-HMC-CR, ZH-HMC-CW are horn I strobes for ceiling mount only. Suffix CR or CW are for ceiling and color. Units are synchronized or non-synchronized strobes. Refer to Listee's data sheet for additional detailed product description and operational RATING: Electrical 16-33VDC/FWR Candela: NS-MC-C, ZH-MC-C = 15/30/75/95 candela NS-HMC-C, ZH-HMC-C = 115 /177 cd NS-MC, ZH-MC = 15/30/75/110 cd ZH-HMC, = 135 / 185 cd Flash Rate: 60 flashes I minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as audible and audible // visual signaling devices for use with separately listed electrically compatible fire control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only. All synchronization strobes shall be used with model DSC sync control module (CSFM listing No. 7300-0067:212). Refer to manufacturer's installation manual for details Note: These appliances can produce a distinctive three- pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: I I 09-07-2007 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct fvI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I I I 1 I I I I I I I I I Li I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household application and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. I APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This I product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. I NOTE: Burglary and other non-fire functions were not examined. I I H I Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator I Fire Engineering Division Listing Expires June 30, 2016 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFX/Aand IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. I I n I I [1 Li I I II I I I I 05-06-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I I