HomeMy WebLinkAbout6195 EL CAMINO REAL; ; AS150363; PermitCity of Carlsbad Sprinkler Permit Permit No: AS150363 6195 EL CAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 2131001800 Lot #: 0 Status: ISSUED Applied 12/15/2015 Approved: 1/13/2016 Reference No.: Issued: 1/13/2016 PC #: Inspector: Project Title: SAFC 6195 EXPANSION RELOCATE AND ADD NEW SPRINKLERS BELOW THE NEW T-BAR CEILING TO ACCOMMODATE FOR NEW WALLS. Applicant: Owner: COSCO FIRE PROTECTION MAMAS HOUSE L L C 4990 GREEN CRAIG LN SAN DIEGO, CA 6195 EL CAMINO REAL CARLSBAD CA 858-444-2000 Fees ($) Add'I Fees ($) Total ($) Balance ($) 438 0 438 0 .000000 I cosco Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lie.: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL Date: 12/10/15 SAFC 6195 EXPANSION 6195 EL CAMINO REAL CARLSBAD, CA 92009 JOB # 10.CD 5661 Submitted by: J. ARVIZU All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. ASIS0363 Los Angeles • San Francisco • Orange 0 Fresno • San Diego • Seattle December 4, 2013 Sprinkler 41a The Viking Corporation, 210 N Industrial Park Drives Hastings MI 49058 Telephone 269-945-9501 Technical Services 877-384-5464 Fax 269-818-1680 Email techsvcs@vikingcorp.com DESCRIPTION Viking Microfast and MicrofastH135 Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester,Poiytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant FM Global has no approval classification for PTFE and Polyester coatings as corrosion resist- ant.) LISTINGS AND APPROVALS cUL.us Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA ) VdS Approved: Certificates G4040095, G4040097, (34060056, (34060057, (34880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e104 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0786-CPD40130, 0786-CPD-40170 and 0786-CPD 40279, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 411 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for VikingTechnical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web Site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- httpflwww.viklnggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500.psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY Is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or OM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 12979, 06666B, and 06765B. Copper tiNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers, Belleville Spring-Exposed, Screw and Pipcap - ENT coated. Form No. F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 06932B toVK3311.) S f Wrench Flat lul Proteci Shieto Protective Sprinkler Cop Sprinkler 41 b December 4, 2013 MICROFASP AND "1 iI(JIJG® MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfast° and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135 OF (57 "C) =A, 155 OF (68 "C) = B, 175 °F(79 "C) = D, 200 OF (93 "C) = E, and 286 OF (141 "C) = G For example, sprinkler VK302 with a 1/2' thread, Brass finish and a 155 OF (88 "C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the 'Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 16036W1B* (available since 2011) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool"'" Part No. 15915 (available since 2010.) "A /z ratchet is required (not available from Viking). "Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F051808- Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. S INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance require- ments. AVAILABILITY The Viking Microfaste and MicrofastHP5 Quick Response Pendent Sprinklers are available through a network of domestic'and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/B 'I December 4, 2013 Sprinkler 41 c 'II MICROFASP AND MicrofastHP® QUICK 1(1 IIG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 268-8184680 Email: techsvcs@vikingcorp.com Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange Ordinary 155 'F (68 'C) 100 'F (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate 200 'F (93 'C) - 150 'F (65 'C) Green High t__286 'F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 'F (57 'C). Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. {j1 Sprinkler Wrench ,/— I I 16O36W/B* for' I pendent sprinklers 'uj1r (not avaliabte from Viking). CreFufly sUde the [I wrench sideways around the protective I. cap, ensuring engage- ment with the sprinkler wrench flats. Figure 2: Wrench 16036W/B for Recessed Pendant Sprinklers Sprinkler 41d December 4, 2013 MICROFAST® AND MicrofastHP® QUICK "4iI 11(1 FJ® RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-8184680 Email: techsvcs@vikingcorp.com Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN k-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric- Inches mm cULus4 NYC VdS LPCB I CE I Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4° 57 AiX, B1Y, C4, E4Z AIX, 3W - - - - 18021 '11(302 1/2" 15 mm 5.6 80.6 2-1/4" 58 AIX, B1Y AIX, B1Y A2 LA2X, B2Y I C2X, E2Y" C2X, E2Y14 V Large Orifice 056668 VK352 3f4fl 20 mm 80 115,2 2-3/8" 60 AIX, BIY, C4, E4Z AIX, B1Y A2 A2X C211 - 06765B15 VK352 1/2° 15 Minn 8.0 115.2 2-3/8" 60 AIX, Bit', C4, E4Z AIX, B1Y A2 - A212 Small Orifice6 0671 8B9 VK329 1I2 15 mm 2.8 40.3 2-3/16" 56 AIX, Bit' AIX, BIY - - - - 06720B9 VK331 1/2° 15 mm 4.2 57 2-1/4" 58 AIX, 8W AIX, B'IY - - - - 06932B '11(3311 - 10 mm 4.2 57 2-3/8" 60 - - A2 - G313 - Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric2 inches mm cULus4 NYC1° VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AIX, B1Y AIX - - .- - Maximum 250 PSI (17 bar) WWP Small Orifice" 1229010 1 '/1(342 11J2" 115 Minn 1 2.8 1 40.3 2-3/16" 1 56 AIX, B1Y AIX Approved Temperature Ratings Approved Escutcheons "C), °F A - 135 "F (57 "C), 155 "F (68 175 (79 "C), 200 "F (93 "C), and Approved Finishes X - Standard surface-mounted escutcheon or 286 F (141 C) C), B - 135 F (57 155 F (88 •C), 175 F (79 C). and 200 F (93 C) 1 - Brass, Chrome, While Polyesler', Black Potyester 7, and Black PTFE9 the Viking Mlcrofast Model F-I Adjustable Escutcheon C - 155 F (68 "C), 175 F (79 C), 200 F (93 C), and 286 F (141 C) 2 - Brass, Chrome, White Polyester7, and Black V - Standard surface-mounted escutcheon or Polyester? the Viking Microfast Model F-I Adjustable 0 - 135 "F (57 "C), 155 "F (68 °C), 175 "F (79 "C), and 286 "F (141 3 Brass and Chrome Escutcheon or recessed with the Viking "C) 4 ENT9 Mlcivmadc° Model E-1, E-2, or E-3 Recessed £ - 155 "F (88 "C), 175'F (79°C), and 200 "F (93 'C) Escutcheon F. 155 "F (68 "C), 175 "F (79 "C), and 286 "F (141 "C) Z - Standard surface-mounted escutcheon or re- - 155 "F (58 "C) cessed with the Viking Micromatic Model E-1 Footnotes Base part number Is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Br. When pressure Is measured in kPa, divide the metric K-factor shown by 10.0. I This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 6 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet Systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pips systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 1 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. ' CC Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40279. 13 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40130 and 0786-CPD40170. 14 ® MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832.MED-1008. 11The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. S 1-1/8' (28.6 mm) Minimum t. 1-3/4' (44.5 mm) Maximum December 4, 2013 Sprinkler 41 MICROFASP AND '1 IF(It1G MicrofastHP5 QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email; techsvcsvikingcorp.com cULus Listing Reaulrements: Microfast' and MicrofastHPw Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small ethics sprinklers are limited to Ught Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance Information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. CeIing Opening Size: 2-5/16 (58.7 mm) minimum I I 2-1/2' (63.5 mm) maximum (54 rim) 1/2' 1I (15 mm) NPT 2-1/4' 1-5/8' (58 mm) (41 mm) I- ____ Pendent Sprinkler 1-3/4' (44.5 mm) Installed with standard 1/8' surface- mounted escutcheon. 2' III I II! 1-1/2' (38.1 rim) (50.8 rim) lJk I ,iJJ Minimum Maximum Installed with a Microfast Model F-i Adjustable Escutcheon * Note: At maximum, adopter Is exposed 1/2' (12.7 mm) from face of ceiling. Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/6' Ceiling Opening Size: 2-1/8- .4 (54 mm) 2-5/16' (58.7 mm) minimum (54 mm) E-1/2' (63,5 mm) maximum Installed with a Micromatic Model E-1 Recessed Escutcheon 2' \JK JI ,II!11/8' (28.6 mm) (50.8 p') Minimum Maximum _________ Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler 41f December 4, 2013 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Sprinkler SIN Thread Size Nominal lactOr Overall Length FM Approvals Base Part No.' NPT BSP U. metric' Inches mm Refer also to Design Criteria be Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A2X, B2Y C3, D3Z 18021 VK302 1/2" 1 15 mmT 5.6 80.6 2-1/4" 58 A2X, B2Y Large Orifice 06666B VK352 3/4" 20 mm 1 8.0 j 115.2 2-3/8" 1 60 A2X, B2Y, C3, D3Z 06765B7 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A2X, B2Y, C3, D3Z Small Orifice4 06718136 VK329 1/2' 115 mm 2.8 40.3 2-3/16" 56 AIX Approved Temperature Ratings Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking A - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and 286 "F (141 "C) Approved Finishes Microfast° Model F-I Adjustable Escutcheon B - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 1 - Brass and Chrome V - Standard surface-mounted escutcheon or the and 200 "F (93 "C) 2 - Brass, Chrome, White Polyester6, and Viking Mierofast Model F-i Adjustable Escutcheon C- 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), Black Polyester6 or recessed with the Viking Micrcmatic8' Model E-1, and 286 "F (141 "C) 3 - ENT E-2, or E-3 Recessed Escutcheon 0 - 155 "F (68 "C), 175 "F (79 "C), and 200 "F Z - Standard surface-mounted escutcheon or recessed (93 "C) with the Viking Micromatice Model E-1 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown Is when pressure is measured In Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the some Listings and Approvals as the standard colors. The sprinkler orifice is bushed. The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. 8 FM approved as corrosion resistant, FM Anoroval Reauirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guldet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (Including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the-ceiling. NOTE: The FM installation guidelines may differ from cULus andlor NFPA criteria. tSpnnklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131 a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for gen-eral care, installation, and maintenance information. Viking sprinklers are to be Installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F081296 Replaces page 41a-f, dated June 28, 2013. (Changed 069326 toVK3311.) FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) .:. NFPA13 Manufacturing Protocols SSchedule 10 and Schedule 40 are subjected j:to the toughest possible testing protocols to ensure the highest quality and long-lasting .performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6' receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer Scoatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet F.M/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 : or A53. All Wheatland galvanized material is :i also UL Listed. Product Marking Each length of Wheatland fire sprinkler sipe Is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL. WEIGHT UL PIECES In. mm In, mm In. mm Iba./ft. kg/rn CRR Lilt 1% 1,660 42.2 1.442 366 109 2.77 81 269 7.3 61 11.4 1.900 483 1682 42.7 .109 2.77 2.09 311 5.8 61 2 2.375 €0.3 2157 548 .109 2.77 266 3.93 47 37 2% 2.875 730 2.635 66.9 .120'-3.05.....353 5.26 35 30 3 3.500 089 3260 828 .120 305 434 6.46 26 19 4 4 500 U4 3 4.260 1082 .120 305 5.62 8.37 16 19 5 5.563 1413 5.295 134.5 .134 3.40 778 51.58 1.5 13 6 6 625 168.3 6 357 161.5 .134 340 930 1385 10 10 8 8.625 2191 8.249 2095 188 4.79 1695 25.26 25 7 Calculated using Standard UL CR8 formula, UI. Fire Protection Directory, Category VIZYY, The CR8 is a ratio value used to measure th, ability of a pipe to withstand corrosion. Threaded Schedule 40 steeipipe Is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm lbs/ft. kg/rn CRR LIft 1 1.315 33.4 1049 266 .133 338 168 250 100 70 l'/i 1.660 422 1380 351 140 356 227 339 100 51 11/2 1.900 483 610 409 145 3.60 272 4.05 100 44 2 2 375 603 2067 55 154 391 5;45*,.:* 2 366 1.00 30 Calculated using Standard (IL CPR formula, UI. Fire Protection Directory, Category VIZY. The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). C& APPROVED LOCATIONS: COMMENTS: I. BLACK J HOT-DIP GALVANIZED Wheatio-nd is 0, NOW A a ~ NE GROOVED OUTLET y I F -r- z FEMALE THREADED OUTLET Provide a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Pressure rated up to 400 psi/2750kPa Sizes from 2xW/50x15mm through 8x47200x100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another Hole Cut Piping System Mechanical-T Bolted Branch Outlet STYLE 920/920N Grooved/Female Threaded Outlet 2 . ½(alu 920N 400 150 200 2.53 1.61 5.35 2.75 3.1 SO 15 2750 38.1 51 64 41 136 70 1.5 - ~(a)c 92211 400 1.50 1.97 2.53 1.61 535 2,75 3.1 20 2750 38.1 50 64 T 41 136 70 1.5 - • 1(a)a 970N 400 1.50 185 2.53 1.61 5.35 2.75 3.0 25 - 2750 381 47 64 41 . 135 70 1.4 - 114(attD 400 1.75 2.05 2.75 3.00 161 5.35 3.00 3.5 3.2 • 32 2750 44.5 52 .?0 .........76 41 136 76 1.7 1.5 1½(a)tu 9flN 400 1.75 2.03 2.75 3.12 151 5.35 : 3.25 ...632 40 . 2750 443 52 70 79 41 136 83 1.7 13 400 1.50 2.21 2.74 91.82 5.642,75:3.0' 65 !,5 2750:38.1 5670 - 46 143 70;1.4' .)9Z3N4001.50 2.18 2.74 - '1825.642,75.3,Q 20 ,. 2750 . 38.1 55 - . 70 46 143. 70 1 (a)6 90N 400 150 2.06 2.74 1.82 5.64 . 2.75 2.9 25 .; 2750 38.1 52 70 46 143 70 1.4 - 1¼t(a)J SON .400:1,75 2.30.3.00 3.25 1826.29.3,003,s'32 32 2750 44.5 58 76 83 46 160 76 ).7 1.5 .1½t(a)Pf9N .4002.00 .2,283.00 3.25182 6.263.253.6 3:3 275O50.8'58 76...........83 46159:831.7 1.6 61 " 9'O 300 1.50 222 275 225 646 318 39 is - 206538.156 70 57:16481 1.8 300130 2.19 2.75 2.25f6.463.18i3.9 20 - 2065 38.1 56 70 - 57 164 81 IS 1(a) 300 150 2.07 . 275 - 2.25 6.46 3.18 3.8 2065 . 38.1 ...-5.3- 70 .7 : 164 81 1.7 10a) d 920 400 175 2.30 300 3.31 192 32 2750 44,5 58 76 84 49 160 76 1.6 1.5 1½ (a) U 400 2.00 2.28 300 331 1.92 629 325 35 33 40 ...r 2150 508 58 76 84 49 160 83 1.6 1.5 WON 4001.502.52 3,05 2.28.5.15 2753.4 80 15 275038.1 64'78 58 155 70:1.6 - :'A (a)u' 920N 400 1.50 2.49 305 . 228 6.15 . ......4 - 70 ,, . 2750 38.1 63 78 - 58 156 70 1.6 - ltalU:9.ON 400L50 2.383.06 2.286152,75;3.3 25 275038.1 6178 38 156701,6 - 1¼(a)taiQ.ON4001.752.55'3,25.355228615:3oo38 3.7 2750 44.565 83908155 751.8 1.8 1½(a)f' DN 400 2.00 2.78 3.50 3.56 2.28 6.15 :3.25 4.1: 38 40(b) 2750 508 71 89 90 58 156 : 83 1.9 1.8 KON 400230 2.75 3.50 3.561286353884946 so 2750 . 63.5 70 _89 50 58 172 99 2.3 2.1 3½' 2 90N 50 400 2.50 - 3.752.446.723.88 90 2750 63.5 .- 95 62 171 99 : 1.8 4.V2 (a)P9QN 400150.3033.56 :269701 2.753.7. 100 - 15 2750 38.1 77 : 90 T 68 178 70 : 1.8 - 400 1.50.3,003.56 2.69:7.01 2.75:3,7 20 2750 38.1 75 90 ....68 178 70 1.8 1 ot' 400 150 288 356 .69 701 27 36 .25 ------------2750.38.1.1390 :58:178 70:1.8 - Ii' (a )t ON 400 175 308 378 400 69 701 300 40 36 275044.5 7896 1O258 17B 76 1.9:1.8 1½(a)fU 9 ON 400 200 328 400 400 69 701 325 42 39 40(b) 2750 50.8 83 102 102 68 I78; 83 2.0: 1.9' 2 'U 9 ON 400 250 325 400 400 LSO 701 388 50 46 .50....j' 215063.5 83 102 102.68:178992,3:11 21h(a)t C20 400 275 288 400 400 259 734 463 58 50 65 . - , 2750 699 : /3 , 102 102 68 ' 186 118 2.6 . 2.3 .761rnrn1c20 4002.75 4.00.2.69:7.34.4.53 6.4 69.9 ...102 68186.118 2.9 3(a)t 80': ... 20 4003.50 .331 4.50u4.122.69:7,73:$12:84 .64 2750.88.984:114 10568:196 1303.8.2.9 Hole Cut Piping System FireLock Outlet-I STYLE 922 n LA 1O.2 Incorporates ½-1'Y10--25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products UL/tJLC Listed, LPCB, VdS/FM Approved for branch connections on wet and dry systems Style. 922 FireLock Outlet-Ts are not approved for cross configurations Pressure rated up to 300 psi/2065kPa and rated up to 230 psif16 Bar at the ambient temperatures typical for fire protection systems Sizes from 1¼x½'732x15mm through 2½x 1776.1 1<25mm 1¼ x ½ 1t4 1.30 183 110 3.87 256 10 32 15 30.2 33.0 46.5 279 983 65.0 045 34 1 M128 183 1.10 387 256 11 20 30.2 32.5 465 279 98.3 650 050 1 13i 152 218 110 38/ 236 1.2 25 30.2 386 554 279 98.3 650 034 1½ '6 134 142 1.95 122 408 256 12 40 15 - 30.2 361 • ......10 650 - 054 1 5A 1.40 1.95 122 408 2.56 1.2 20 . 30.2 356 495 310 1036 65.0 054 1 I I M6 164 230 1.22 408 2.58 1.3 25 30.2 41.7 58.4 31.0 103.6 650 059 2 ½ ' 1A 1.66 219 1.46 4.60 2.56 1.3 50 15 30.2 422 55.6 371 1168 650 059 ¼ 1346 164 2.19 146 460 2.56 14 20 302 41.7 55.6...371 116.8 - 65.0 064 1 1%4 188 2.54 1.46 460 256 15 30.2 478 645 37.1 1168 650 0.68 2½ ½ 1 34f 191 244 1.71 5.40 256 16 65 15 30.2 48.5 620 434 1372 650 073 34 I 1 V14 1.89 244 1.71 5.40 2.56 16 20 30.2 48D 620 43.4 1372 650 073 1 1 II, 2.13 2.79 1.71 540 2.56 1.6 25 302 541 - 70.9 - 43.4 1372 65.0 0.73 761 m M ½ 1 t 1.91 2.44 1.71 550 256 1.6 x .15 302 485 620 434 1397 650 073 34 1346 1.89 244 1.71 530 2.56 16 - 20 302 480 620 434 1397 65.0 073 1 13 213 2.79 1.71 5.50 256 17 75 I 302 541 70.9 434 1397 65.0 0.80 f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc, should be verified as suitable for use with this Victaulic product. Failure to verify sOitability in advance may result In assembly problems or leakage, - * Center of run to engaged pipe end for NPT threads (dimensions are approximate). Vi, DUCTILE IRON 90 DEG. ELBOW NOMINAL SIZE (INCH) ITR CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT A - B EACH PIECE 1 DB90033 500 1.50 1.50 0.62 11/4 0890044 500 1.75 1.75 T 0.90 11/2 0890055 500 1.94 1.94 120 2 0890066 500 2.25 1 2.25 1.85 DUCTILE RED.90 DEG. ELBOW NOMINAL SIZE (INCH) rr. CODE MAX. WORKING P.S.I. DIM IONS W8GHT A - B EACH PIECE IX112 0690031 500 1.26 1.36 0.44 1X314 0690032 500 1.37 1.45 0.52 I 1/4X1/2 0890041 500 1.34 1.53 0.64 I 1!4X314 0890042 500 1.45 1 1.62 0.72 I 114X1 0890043 500 1.58 1 1.67 0.75 I 112X1 01390053 500 1.65 1.80 0.92 I 1/2X1 1/4 D890054 . 500 1.82 TI 1.03 2X1/2 0890061 500 1.49 1.88 1.08 2X314 0890062 500 1.60 1.97 1.24 - 2X1 D890063 500 1.73 202 1.40 2X1 114 0890064 500 1.90 1 2.10 1.52 2X1 1/2 DB90065 500 2.02 1 2.16 1.65 DUCTILE IRON COUPLIN G I NOMINAL1 SIZE (INCH) ITEM CODE MAX. WORKING PSI. IDlMB4SlONI . A W19CIT1 EACH PIECE I 0C1033 - 500 1.67 0.40 1.1/4 1 tL044 500 1.93 0.57 11/2 DCLOSS 500 2.15 0.75 2 0QL066 1 500 2.53 - 1.15 UCTILE NOMINAL SIZE I (INCH) IRON IT CODE # 45 DEG. MAX. WORKING P.S.I. ELBOW DIM IONS A B WEIGHT EACH PIECE I I 0845033 500 1.12 1.12 0.46 1114 0845044 500 1.29 1.29 0.73 [1/2 0845055 500 1.43 1.43 0.92 L 2 D845066 500 1.68 1.68 1 1.50 'DUCTILE IRON STRAIGHT TEE INCMINAL I (INCH) ITEM CODE I MAX. WORKING PSI. G IZE IDIMB4SIONS A 7FAA CH B .CE 1 . br333 .500 1.50 .15085 11/4 DT444 5p0.. 1.75 1.7522 1 1/2 01555 500 1.94 1.94 1.55 2 D1666 . 500 225 2.45 A DUCTILE IRON RED. COUPLING NOMINAL ITEM SIZE. CODE (INCH) N MAX. WORKING P.5.1. DIM thSION WEIGHT EACH PIECE A 1X172 DRC031 500 1.69 . 0.39 1X3t4 0RC032 500 1.69 0.53 I D.I. THREADED FITTINGS STAR®PIPEPRODUCTLS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi service. Ductile iron per ASTM A 536 grade 65-45-12. Dimensions conform to ANSI 1316.3 class 150. Threads are NPT per ANSI/ASME 13I.20.1. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron littingd should be tightened theree turns beyond hand tight, but no more than four turns. Page 21 D.I. THREADED FITTINGS Page 22 -:-DUCTILE IRO I CROSS MAX. WORKING P.S.I DIM B4SIONS WEIGiff ODE ~INAL (INCH) A B E&CH PIECE 1 DX033 500 1.50 1.50 0.98 11(4 DX044 500 1.75 1.75 1.50 1.112 DX055 500 1.94 1.94 1.90 2 DX066 500 2.25 2.25 2.95 I 1/4X1 DX043 500 158 1.67 1.27 I 112X1 0X053 500 1.65 1.80 1.48 2X1 DX063 500 1.73 2.02 2.10 OUTSIDE HEAD INSIDE HEAD DUCTILE!1L NOMINAL. SIZE INCH) ITEM I CODE # DIMENSIONS STYLE I I EACH - A - B C x112 DBIJSH3I 0.15 0.25 1.42 OUT 0.22 1x314 DBUSH32 0.75 0.25 1.42 JOUT 0.171 I I/4xI DBUSH43 0.80 0.28 111.76 JOUT 0.28 1 I I/20 DBUSH53 0.83 0.31 2.00 JOUT 0.44] I 1/2x1 1/4 DBUSH54 0.83 ] 2x1 DBUSH63 088 2x1 1/4 DBUSH64 0.88 *1.95 2x1 1/2 DBUSH650.88 LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 DUCTILE IRON REDUCING - TEE !J4 :4JIfr W.,L,= WAIR K11A I T)4P fi if ¼ 4O P{. F4'L!' !JLI' ';' 4 - p. ]J)14H1fr F 0 :'i .y &,L:4I,Lcfr. IJ4Irc Ifr4E i.1 _fI_ iwa Ifr 4'F P'Ir Ifr4I1ki4! PLi IIrEI)" 'it Ifr4&!rfL ,i14' 14 KIM :rjiJL-!ItF Pi' . I'.!'! - -fl Fig. 200 - "Trimline" Adjustable Band Hanger C us LISTED Fig. 200R (import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2N) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21h thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31A 25A 400 11 3/4 3/8 8mm or 10mm 31/a 21h 400 11 1 3/8 8mm or 10mm 3% 25A 400 12 11/4 3/8 8mm or 10mm 3Y4 27/6 400 13 11/2 3/8 8mm or10mm 3½ 400 14 2 3/8 8mm or 10mm 41h 3 400 15 2112 3/8 10mm 5% 41/4 600 27 3 3/8 10mm 57A 4 600 29 31/2 3/8 10mm 7% 51/4 600 34 4 3/8 10mm 7Va 5 1000 35 5 1/2 12mm 91/s 61/4 1250 66 6 1/2 12mm 101/8 6-Y4 1250 73 8 1/2 12mm 131A 83/4 1250 136 OFFlCEfilANUFACTURING FACILITY • 1375 SAMPSON AVE sCOIIONA, CA 92879 • PH: 951.7375599. F(: 951.737.0330 CUSTOMER SERVICE • 800.786.5265 www.toko.com / Fig. 25 - Surge Restrainer Size Range - One size fits 3/4' thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed pniy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 C®US USTO 0 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 051.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.788.5266 wwwtolco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* Wt./100 3/8 1¼6 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* WtJ100 3/8 1 SA6 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 518 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or don position. I Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/411 Throat Openings Component of State of California OSI-IPD Apploved c Seismic Restraints System ®" USIW Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2' and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737,5586 • FAX: V51 337.0330 CUSTOMER SERVICE • 800.780.5266 www.toliw.com Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Component of State of Seismic Restraints System California OSHPC Approved c Us LMM Size Range - 3/8"and 1/2' rod; 4" thru 16" length. Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of N,IFPA 13 (1999) 6-4.7.1. Features Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section "A-A" or inverted. Allows easy installation for new construc- tion or retrofit applications. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore, a locking mechanism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable instal- lation. Approvals - Underwriters' Laboratories listed in the , USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalpa aoDrtved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, rod or set screw size and length Note - Minimum return on strap: i Dimensions *Patent 45,94 7,424 Rod Size A Length 3f8' Specify 1/2" Specify OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.7855266 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System FIG. 98 Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98- Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8° thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office .of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number LI] FIG. 9! Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8 thru 7/8 rod in 1' increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. I IL • Size Range — Secures 3/8" thru 1 1h" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750*F Finish ~ Plait: Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps App rox. Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1½ 13800 510 g OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwiofco.co , Expansion Cone I 4.3.4 Kwik Bolt TZ Expansion Anchor 4.3.4.1 Kwlk Bolt TZ Product Description 4.3.4.1 Product Description 4.3.4.2 Material Specifications 4,3.4.3 Technical Data 4.3.4.4 Installation Instructions 4.3.4.5 Ordering Information 4.3.4.6 Sample Calculations Impact Section (Dog Point) Nut Washer Red Settin Mark Stainle Stee Expans Slee, (Wedg Listincls/AnDrovals ICC-ES (International Code Council) ESR-1917 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems (3/8 - 3/4') UL (Underwriters Laboratories) Pipe Hanger Equipment for Fire Protection Services (3/8' - 3/4) The Kwik Bolt 12 (KB-TZ) is a torque controlled expansion anchor which is especially suited to seismic and cracked concrete applications. This anchor line is available in carbon steel with zinc electroplated coating and 304 stainless steel versions. The anchor diameters range from 3/8 to 3/4 inch in a variety of lengths. Applicable base materials Include normal-weight concrete, structural lightweight concrete, and lightweight concrete over metal deck. Guide Specifications Torque controlled expansion anchors shall be Kwik Bolt 17 (KB-TZ) supplied by Hilti meeting the description In Federal Specification A-A 1923A, Type 4. The anchor bears a length identification mark embossed into the impact section (dog point) of the anchor surrounded by four embossed notches identifying the anchor as a Hilti Kwik Bolt TZ in the Installed condition. Anchors are manufactured to meet one of the following conditions: The carbon steel anchor body, nut, and washer have an electroplated zinc coating conforming to ASTM B633 to a minimum thickness of 5 pm. The stainless steel expansion sleeve conforms to AlSi 316. Stainless steel anchor body, nut and washer conform to AlSI 304. Stainless steel expansion sleeve conforms to AlSl 316. Product Features Product and length identification marks facilitate quality control after installation. Through fixture Installation and variable thread lengths improve productivity and accommodate various base plate thicknesses. 316 Stainless Steel wedges pro- vide superior performance In cracked concrete. Ridges on expansion wedges provide increased reliability. Mechanical expansion allows immediate load application. Raised impact section (dog point) prevents thread damage during installation. Bolt meets ductility requirements of ACI 318-05 Section Dl. Installation Drill hole in base material to the appropriate depth using a Hilti carbide tipped drill bit. Drive the anchor into the hole using a hammer. A minimum of four threads must be below the fastening surface prior to applying installation torque. Tighten the nut to the recommended installation torque. Anch Threa . Anchc Body Supplemental Design Provisions for ACI 318-05 Appendix D Design strengths are determined in accordance with ACI 318-05 Appendix D and ICC Evaluation Service ESR-1 917 Hilti Kwlk Bolt 12 Carbon and Stainless Steel Anchors in Concrete. The relevant design parameters are reiterated in Tables 1, 2, and 3 of this document. Supplemental provisions required for the design of the KB-TZ are enumerated In Section 4.0 of ESR-1917 (DESIGN AND INSTALLATION). Note that these design parameters are supplemental to the design provisions Building Code Compliance of ACI 318-05. IBC® 2006 IRC® 2006 UBce 1997 316 Hitfl, Inc. (US) 1-800-879-8000 1 www.us.hllti.com I en espal'IoI 1-800-879-5000 1 Rilti (Canada) Corp. 1-800.363-4458 1 www.hilti.ca I Product Technical Guide 2008 Mechanic-al Anchoring System Kwik Bolt TZ Expansion Anchor 4.3.4 4.3.4.2 Material Specifications Carbon steel with electroplated zinc Carbon steel KB-TZ anchors have the following minimum bolt fracture loads' Anchor Diameter (in.) Shear (lb) Tension (Ib) 3/8 NA 6744 1/2 7419 11240 518 11465 17535 3/4 17535 25853 Carbon steel anchor components plated in accordance with ASTM 8633 to a minimum thickness of 5pm. Nuts conform to the requirements of ASTM A563, Grade A, Hex. Washers meet the requirements of ASTM F844. Expansion sleeves (wedges) are manufactured from AISI 316 stainless steel. Stainless steel Stainless steel KB-TZ anchors are made of AISI 304 material and have the following minimum bolt fracture loads' Anchor Diameter (In,) Shear (Ib) Tension (ib) 3/8 5058 6519 1/2 8543 12364 5/8 13938 19109 3/4 22481 24729 Nuts meet the dimensional requirements of ASTM F594. Washers meet the dimensional requirements of ANSI 1318.22.1, Type A, plain. Expansion Sleeve (wedges) are made from AISI 316. All nuts and washers are made from AISI 304 stainless steel. 1 Bolt fracture loads are determined by testing in jig as part of product ac. These loads are not intended for design purposes. See Tables 2 and 3. S I ............ Hitti, inc. (US) 1.800-879-8000 1 www.us.hiFU.com I on espaf'tol 1-800-879-5000 1 Huh (Canada) Corp. 1-800-363-4458 Iwww.hlltica I Product Technical Guide 2008 317 Mcchanical AncharincITmki I. 4.3.4 Kwik Bolt TZ Expansion Anchor 4.3.4.3 Technical Data Table I - Kwik Bolt TZ Specification Table SETTING Symbol urift ________________ Nominal anchor diameter (In.) 3/8 1)2 518 314 INFORMATION Anchor 0.1) d0 in. 0.375 0.5 0.625 0.75 (mm) (9.5) (12.7) (15.9) (19.1) Nominal bit dblt in. 3/8 112 5/8 3/4 diameter Effective mm. hot in. 2 2 3-1/4 3-1/8 . 4 3-3/4 4-3/4 embedment (mm) (51) (51) (83) (79) (102) (95) (121) Mm, hole depth /i in, 2-5/8 2-5/8 4 3-3/4 4-3/4 4-5/8 5-3/4 (mm) (67) (67) (102) (95) (121) (117) (146) Min. thickness of ma in, 1/4 3/4 1/4 3/8 3/4 1/8 1-5/8 fixture, (mm) (6) (19) (6) (9) (19) (3) (41) Max. thickness of in. 2-1/4 4 2-3/4 5-5/8 4-3/4 4-5/8 3-5/8 fixture (mm) (57) (101) (70) (143) 1 (121) (117) (92) Installation torque Tbyt ft-lb 25 40 60 110 (Win) (34) (54) (81) (149) Min, dla.of hole d In. 7/16 9/16 11/16 13/16 in fixture (mm) (11.1) (14.3) (17.5) (20,6) Available anchor in, 3 3-3/4 5 3-3/4 4-1/2 5-1/2 7 4-3/4 6 8-1/2 10 5-1/2 8 10 lengths (mm) (76) (95) (127) (95) (114) (140) (178) (121) (152) (216) (254) (140) (203) (254) Threaded length in. 7/8 1-5/8 2-7/8 1-5/8 2-3/8 3-3/8 4-7/8 1-1/2 2-3/4 5-1/4 6-3/4 1-1/2 4 6 including dog point (mm) (22) (41) (73) (41) (60) (86) (178) (38) (70) (133) (1.71) (38) (102) (152) Unthreaded length I unft in. 2-1/8 2-1/8 3-1/4 4 (mm) (54) (54) (83) (102) Installation mm in. 2-1/4 2-3/8 3-5/8 3-5/8 4-1/2 4-3/8 5-3/8 embedment (mm) (57) (60) (92) (92) (114) (111) (137) 1 The minimum thickness of the fastened part is based on use of the anchor at minimum embedment and is controlled by the length of thread. If a thinner fastening thickness is required, increase the anchor embedment to suit. Figure 1 - Kwik Bolt TZ installed Ll €anch 318 Hilti. Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en eapañol 1-800-879-5000 1 Hill! (Canada) Corp. 1-800-383-4458 1 www.hltLca I Product Technical Guide 2008 Mechanical Anchoring ie Kwik Bolt 12 Expansion Anchor 4.3.4 Table 2- Carbon Steel Kwik Bolt TZ Strenóth Design Infomiation DESIGN Symbol Units Nominal anchor diameter INFORMATION 3/8 1/2 5/8 3/4 Anchor 0.D. do in, 0.375 0.5 0.625 0.75 .J!!L (9.5) (12.7) - (15.9) (19.1) - Effective rein. hel in. 2 2 3-1/4 3-1/8 4 3-3/4 4-3/4 embedment' (mm) (51) 1) (83) (79) (102) (95) (121) Min. member thickness h , 415 416 618 5 618 6 1 8 8 JL (102) (127) (102) I (152) (152) (203) (127) (152) I (203) (152) (203) (203) Critical edge distance cac in. 4-3/8 4 5-112 I 4-1/2 7-1/2 6 16-17 8-3/4 I 6-3/4 10 I 8 (mm) (111) (102) (140) I (114) (191) (152) (165) (222) I (171) (254) I (203) (229) in. 2-1/2 2-3/4 2-3/8 3-1/4 4-3/4 417 Min. distance edge (mm) (64) (70) (60) 2) (83) (121) (105) fors? in. 5 5-3/4 5-3/4 17 5-7/8 10-1/2 8-7/8 (mm) (127) (146) (146) (156) 1 (149) (267) (225) Smin in, 2-1/2 2-3/4 2-3/8 3-17 3 5 Mm. anchor spacing (mm) (64) (70) (60) (89) (76) (127) (102) - for c ------- in. 3-5/8 4-1/8 3-1/2 4-3/4 4-1/4 9-1/2 - 7-3/4 (mm) (92) (105) (89) (121) (108) (241) (197) Mm. Pole depth in. 25/8 2-5/8 in concrete (mm) (67) (67) (102) (98) (121) (117) (146) Mm. specified fy(N/mm2) Ib/in2 100000 84800 84800 84800 - yield strength (690) (585) (585) (585) Mm. specified I,' lbAn2 125000 106000 106000 106000 ult. strength (N/mm2) 1 (862) (731) (731) (731) Effective tensile A 512 0.052 0.101 0.162 0.237 stress area (rem2) (33.6) (65.0) (104.6) (152.8) Steel strength lb 6500 10705 17170 25120 intension (lcN) (28.9) (47.6) (76.4) (111.8) Steel strength lb 3595 6405 10555 15930 in shear VSa (kN) (16,0) (28.5) (47.0) (70.9) Steel strength in KSeis lb 2255 6405 10555 14245 shear, seismic -. (kN) (10.0) (28.5) (47.0) (63.4) Steel strength in sheer, lb 2130 3000 4945 4600 I 6040 NP concrete on metal deck2 (ld (9.5) (13.3) (22) (20.5) (26.9) Pullout strength lb 2515 NA 5,515 NA I 9,145 8,280 I I 10,680 uncracked concrete3 (11.2) (24.5) (40.7) (36.8) 1 (47.5) Pullout strength N lb 2270 NA 4,915 NA NA cracked concrete3 (k (10.1) (21.9) 1 Pullout strength concrete lb 1460 1450 2620 2000 4645 NP on metal deck4 (kN) (6.5) (6.5) (11.7) .9) Anchor category5 Effectiveness (actor kr uncrecked concrete 24 Effectiveness factor k, cracked concrete 17 PcN = kun,jlkcr1 1.41 Strength reduction factor 4, for tension, steel failure modes 8 0,75 Strength reduction factor 4) for shear, steel failure modes8 0.65 Strength reduction factor 4) for tension, concrete failure modes, Condition B 0.65 Strength reduction factor 4) for shear, concrete failure modes 0.70 See Fig. 1. NP (not permitted) denotes that the condition is not supported. NA (not applicable) denotes that this value does not control for design. NP (not permitted) denotes that the condition is not supported. Values are for cracked concrete. Values are applicable to both static and seismic load combinations. See ACI 318 D.4.4. See ACI 318 0.5.2.2. See ACI 318 D.5.2.6. The KB-TZ is a ductile steel element as defined by ACI 318 D.1. For use with the load combinations of ACI 318 9.2. Condition B applies where supplementary reinforcement in conformance with ACI 318 D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary rein- forcement can be verified, the strength reduction factors associated with Condition A may be used. Hi 1, Inc. (US) 1-800-879-8000 1 www.us.h91.coni I an espafiol 1-800-879-5000 1 I4iIti (Canada) Corp. 1-800-363-4458 1 www.hlltLcj I ProduciTechnical Guide 2008 319 Mechanical _ 43.4 Kwik Bolt TZ Expansion Anchor Table 3- Stainless Steel Kwlk Bolt 17 Strength Design Information DESIGN Symbol Units Nominal anchor diameter 3/8 1/2 5/8 3/4 INFORMATION Anchor 0.D, in. 0.375 0.5 0.625 0.75 3m) (9.5) (12.7) (15.9) (19.1) Effective mm. in. 2 2 3-1/4 3-1/8 4 3-314 embedment' (mm) (51) (51) (83) ...29L. (102) (95) 1 J!!L M In. rnemberthickness hmin 6 5 I 8 I 5 6 8 5 I I (mm) (102) I (127) (1 D2) (152) (152) (203) (127) (152) (203) (152) (2 3) Critical edge distance cac in. 4-3/8 I 3-7/8 5-1/2 4-1/2 7-1/2 I 6 7 8-7/8 I 6 10 I 7 (mm) (111) (98) (140) (114) (191) (152) (178) (225) (153) (254) (178) ....(22). in. 2-1/2 2-7/8 2-118 3-1/4 2-3/8 4-1/4 4 Mm. distance J!!!IL (64) (73) (54) JL (60) (108) iic!?L. edge fors in, 5 5-3/4 5-1/4 5-1/2 5-1/2 10 8-1/2 (mm) (127) (146) (133) (140) (140) (254) (216) in. 2-1/4 2-7/8 2 2-3/4 2-3/8 5 4 Mm. anchor spacing 3m1n (mm) (57) (73) (51) J7 (60) (127) J! for c in, 3-1/2 4-1/2 3-1/4 4-1/8 4-1/4 9-1/2 7 (mm) (89) (114) 1 (83) (105) (108) (241) (178) Mm. hole depth In. 2-5/8 2-5/8 1 4 3-3/4 4-314 4-5/8 5-3/4 in concrete (mm) (67) (67) (102) (95) (121) (117) (146) Mm. specified ry Ib/in2 92000 92000 92000 76125 yield strength (N/mm2) (634) (634) (634) (525) Mm. specified f u ib/in2 115000 115000 115000 101500 aft. strength (8/11m2) (793) (793) (793) (/00) Effective tensile A e mn2 0.052 0.101 0.162 0.237 stress area (mn12) (33.5) (65.0) (104.6) (152.8) Steel strength lb 5980 11615 18630 24055 in tension (kf (26.6) (51.7) (82.9) (107.0) Steel strength to 4870 6880 11835 20050 in shear (ktl) (21.7) (30.6) (52./) (89.2) Steel strength in tension, N,,, lb NA 2,735 I I NA NA NA seismic2 (k N) (12.2) Steel strength in shear, Vsa,seis lb 2825 6880 11835 14615 seismic2 (lct) (12.6) (30.6) (52.6) (65.0) Pullout strength N, lb 2630 NA 5760 Nit NA I 12040 uncrecked concrete 2 ' (kI) (11.1) (25,6) 1 (53.6) Pullout strength cracked lb 2340 3180 NA NA ' 5840 I 8110 I NA concrete2 (W) (10.4) (14.1) I (260) (36.1) I Anchor category3 Effectiveness factor k-a uncracked concrete 24 Effectiveness factor k1 cracked concrete 17 I 24 I 17 1 17 17 I 24 I 17 = kum Ik,5 1.41 I 1.00 I 1.41 1 1.41 1.41 1.00 [ 1.41 Strength reduction factor 4) for tension, steel 0.75 failure modes 6 Strength reduction factor 4, for shear, steel 0.65 failure modes6 Strength reduction factor 4) for tension, 0.65 concrete failure modes, Condition B1 Strength reduction factor 4) for shear, concrete failure modes 0.70 See Fig. 1. NA (not applicable) denotes that this value does not control for design. See ACI 318 0.4.4. See ACI 318 D.5.22. See ACI 318 0.5.2.6. The KB-TZ is a ductile steel element as defined by ACI 318 0.1. For use with the load combinations of ACI 318 9.2. Condition B applies where supplementary reinforcement in conformance with ACI 318 0.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. C 320 Hull, Inc. (US) 1-800-879-8000 1 www.us.hltti.com I en espaiSol 1-800-879-5000 1 Hi1ti (Canada) Corp. 1-800-363-4.458 1 www.hiftLca I Product Technical Guide 2008 Mechanical Anchoring Systerns Kwik Bolt TZ Expansion Anchor 4.34 Figure 2—Interpolation of Minimum Edge Distance and Anchor Spacing Sdesign Cdesian - SdeSjgn h?hmin Ca min at s Cdesign edge distance c Table 4— Mean Axial Stiffness Values (1000 lb/in.) for Kwik Bolt TZ Carbon and Stainless Steel Anchors in Normal-Weight Concrete' Concrete condition carbon steel KB-TZ, all diameters stainless steel KB-TZ, all diameters uncracked concrete 700 120 cracked concrete 500 90 1 Mean values shown. Actual stiffness may vary considerably depending on concrete strength, loading and geometry of application. Figure 3—Installation in Concrete over Metal Deck Floor Mm. 5I8 Typical L Mm. 3000 psi Normal or Sand - U cc Lightweight Concrete Upper Flute Min. 4-117 Min .4-1/2 -I- - Max. 1' Offset Typical Minimum No. 20 Gauge Steel Deck Lower Flute (Ridge) 9 I-Sal, Inc. (US) 1-800-8794000 1 www.usiiittLcom I an espuñol 1-800-879-5000 1 HitS (Canada) Corp. 1-800-363-4458 1 wwwhtltkca I Product Technical Guide 2008 321 Mechanic-91 Anchoring Systeirs 4.34 Kwik Bolt TZ Expansion Anchor Allowable Stress Design Design values for use with allowable stress design (working stress design) shall be established as follows: Ra,Aso= .d where Rd = 4, Rk represents the limiting design strength intension (4, N) or shear (4, V) as calculated according to AC! 318 D.4.1,1 and 0.4.1.2 Table 5—The value of a shall be taken as follows: Reference for strength reduction factors cc including seismic excluding seismic ACI 3180.4.4 1.1 1.4 AC! 318 D.4.5 1.2 1.55 Table 6- Kwik Bolt TZ Carbon and Stainless Steel Allowable Static Tension (ASD), Normal-Weight Uncracked Concrete, Condition B (lb)1Z34 Nominal Anchor Diameter Embedment Depth her (In.) Concrete Compressive Strength2 ___________ f lc= 25OOpsi PC= 30W fc4000PSi f kc=6OOOpsi Carbon Steel Stainless Steel Carbon Steel Stainless Steel Carbon Steel Stainless Steel Carbon Steel Stainless Steel 3/8 2 1168 1221 1279 1338 1477 1545 1809 1892 1/2 2 1576 1576 1726 1726 1993 1993 2441 2441 3-1/4 2561 2674 2805 2930 3239 3383 3967 4143 3-1/8 3078 3078 3372 3372 3893 3893 4768 4768 5/8 4 4246 4457 4651 4883 5371 5638 6578 6905 3-3/4 3844 4046 4211 4.432 4863 5118 5956 6268 3/4 4-314 4959 5590 5432 6124 6272 7071 1 7682 8660 1 Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of Rd as per AC! 318-05 and conversion to ASO in accordance with Table 5. 2 Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See ACI 318-05 D.3.4, 3 Condition B applies where supplementary reinforcement in conformance with ACI 318-05 D.4.4 Is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. 4 Allowable static tension loads for 2,500 psi are calculated by multiplying the concrete breakout strength 4 by the strength reduction 4, factor of 0.65 and dividing by an (t of 1.4 according to ICC ESR-1917 Section 4.2. Nb is calculated as per ACI 318-05 D.5.2,2. This load may be adjusted for oilier concrete strengths according to ICC ESR-1917 Section 4,1.3 by using the following equation. Nof'C= N Table 7 - Kwik Bolt TZ Carbon and Stainless Steel Allowable Static Tension (ASD)I Normal-Weight Cracked Concrete, Condition B (tb)l,23,4 Nominal Anchor Diameter Embedment Depth h0, (in.) Concrete Compressive Strength2 f c=2500psi f'c=3000psi fc=4000psi f'=6OOOpsi Carbon Steel Stainless Steel Carbon Steel Stainless Steel Carbon Steel Stainless Steel Carbon Steel Stainless Steel 3/8 2 1054 1086 1155 1190 1333 1374 1633 1683 2 1116 1476 1223 1617 1412 1868 1729 2287 1/2 3-1/4 2282 2312 2500 2533 2886 2925 3535 3582 518 3-1/8 2180 2180 2388 2388 2758 2758 3377 3377 3157 2711 3458 2970 3994 3430 4891 4201 3/4 3-3/4 2866 3765 3139 4125 3625 4763 4440 5833 4-3/4 4085 4085 4475 1 4475 5168 5168 6329 6329 1 Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of Rd as per ACI 318-05 and conversion to ASD in accordance with Table 5. 2 Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See ACI 318-05 0.3.4. 3 Condition B applies where supplementary reinforcement in conformance with ACI 318-05 0.4.4 Is not provided, or where pullout or pryout strength governs. For cases where the . presence of supplementary reinforcement can be verified, the strength reduction factors associated with ConditIon A may be used. 4 Allowable static tension loads for 2,500 psi are calculated by multiplying the pullout strength NO by the strength reduction 4, factor of 0.65 and dividing by an cc of 1.4 according to ICC ESR-191 7 Section 4.2. See Table 2 for Nm. This load may he adjusted for other concrete strengths according to ICC ESR-1 917 Section 4.1.3 by using the following equation. = N0 V Z-00 322 Hllti. Inc. (US) 1-800-879-8000 1 www.us.hiltl.com I en espaflot 1-600-879-5000 1 Hifti (Canada) Corp. 1-800-363-445e 1 www.hllti.ca I Product Technical Guide 2008 Kwik Bolt TZ Expansion Anchor 4.34 Table 8- Kwik Bolt TZ Carbon and Stainless Steel Allowable Static Shear (ASD), Steel (lb)I,2 Nominal Anchor Diameter Allowable Steel Ca pacity, Static Shear Carbon Steel Stainless Steel 318 1669 2661 1/2 2974 3194 5/8 4901 5495 3/4 7396 1 9309 1 Values are for single anchors with no edge distance or spacir.g reduction due to concrete failure. 2 Allowable static shear loads are calculated by multiplying I' y the strength reduction 4) factor of 065 and dividing by an aol .4 according to ICC ESR-1917 Section 4.2. See Table 2 for V. Table 9- Kwik Bolt TZ Carbon and Stainless Steel Allowable Seismic Tension (ASD), Normal-Weight Cracked Concrete, Conditon B (Ib)1,2.34 Nominal Anchor Diameter Embedment Depth hot on.) Concrete Compressive Strength2 fc=2500psi fc0psi ft=4O00psi f €=6000psi Carbon Steel Stainless Steel Carbon Steel Stainless Steel Carbon Steel Stainless Steel Carbon Steel Stainless Steel 3/8 2 1006 1037 1102 1136 1273 1312 1559 1607 1/2 2 1065 1212 1167 1328 1348 1533 1651 1878 3-1/4 2178 2207 2386 2418 2755 2792 3375 3419 3-1/8 2081 2081 2280 2280 2632 2632 3224 3224 5I8 3014 2568 3301 2835 3812 3274 4669 4010 3-3/4 2736 3594 2997 3937 3460 4546 4238 5568 3/4 4-3/4 1 3900 3900 4272 4272 4933 4933 6042 6042 1 Values are for single anchors with no edge distance or spacing reduction. For other cases, cticulaticn of Rd as per ACl 318-05 and conversion to PD in accordance with Table 5. 2 Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. Sen ACI 318-05 0.3.4. 3 Condition B applies where supplementary reinforcement in conformance with AC1 318-05 0.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. 4 Allowable seismic tension loads for 2,500 psi are calculatec by mull 1plylng the pullout strength Npv by the strength reduction 4) factor of 0.65, then multiplying by a 0.75 factor describe In ACt 318-05 0,3.3.3, and dividing by an a of 1.1 according to ICC ESR-1917 Section 4.. See Table 2 for Mm. This load may be adjusted for other concrete strengths according to ICC ESR-t 917 Section 4.1.3 by using the followirg equation. = Nnn,cr Vo Table 10- Kwik Bolt TZ Carbon and Stainless Steel Allowable Seismic Shear (ASD), Steel (lb)i,2 Nominal Anchor Diameter Allowable Steel Capacity, Seismic Shear Carbon Steel Stainless Steel 3/8 999 1252 1/2 2839 3049 5/8 4678 5245 3/4 6313 1 6477 1 Values are for single anchors with no edge distance or spacing reductloi due to concrete failure. 2 Allowable seismic shear loads are calculated by multiplying Vsk seis by the strength reduction 4) factor of 0.65, then multiply by 0.75 as per ACI 318- 050.3.3.3, and dividing by an cc of 1.1 according to ICC ESR-1917 Suction 4.2. See Table 2 for Hilti, Inc. (uS) 1-800-879-6300 1 www.us.hilti.com I en espartol 1-8)0-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 1 www.hfltl.ca I Product Technical Guide 2008 323 S Mcchanical IAnchoringI S 4.3.4 Kwik Bolt TZ Expansion Anchor Table 11 - Kwik Bolt TZ Carbon Steel Allowable Tension and Shear Loads (ASD), Installed Into the Underside of a Lightweight Concrete over Metal Deck Slabl,2,3 Nominal Anchor Diameter Embedment Depthh fin.) Tension Seismic 0b)4 Tension non-Seismic (lb)5 Shear Seismic (lb)4 Shear non-Seismic (lb)5 3/8 2 709 743 944 989 1/2 2 709 743 1330 1393 1/2 3-1/4 1272 1333 2192 2296 5/8 1 3-1/8 971 1017 2039 2136 5/8 4 2255 2362 2677____l 2804 1 Pullout strength values Npn,duk are for anchors installed in lightweight concrete having a minimum 2,500 psi compressive strength at the time of installation. See Table 3 ESR-1 917. The values listed in Table 11 have been calculated assuming a minimum 3,000 psi concrete compressive strength. The pullout strength may be adjusted for other lightweight concrete compressive strengths according to ICC ESR-1917 Section 41.3 using the following equation: NPfldodc,I'C = iVpfldrJ (ib, psi) V T500 2 Minimum anchor spacing along the flute shall be the greater of 3.0 1>1>01 1.5 times the flute width in accordance with ICC ESA-1917 Section 4.1.3. 3 Anchors in the lower flute may be installed with a maximum 1 -inch offset in either direction. See Figure 5 in ESR-1917. 4 Allowable seismic tension and shear loads are calculated by multiplying Np,,O,,h and V>d>,, by the strength reduction 4> factor of 0.65, the seismic reduction 4> factor of 0,75 according to AD 318 03.33, and then divided by an a of 1.1 according 101CC ESR-1917 Section 4.2. 5 Allowable non-seismic tension and shear loads are calculated by multiplying Nw>d, and by the strength reduction 0 factor of 0.65 and dividing by an a of 1.4 according to ICC ESR-1 917 Section 4.2. Table 12 — Kwik Bolt TZ Length Identification System Length lDmarking A B C D E I F G 1 14 J K L M N 0 P 0 R S I I I U V w on bolt head Length of From 11/2 2 21,4 3 31/> 4 41/2 5 51/2 6 61,4 7 71/2 8 81,4 9 9% 10 11 12 13 14 15 anchor, Up to but ear,cfin.) not 2 21/> 3 31,4 4 41/2 5 51/. 6 61/2 7 71,4 8 81/2 9 91/2 10 11 12 13 14 15 16 including Figure 4— Bolt Head with Length Identification Mark and Kwik Bolt TZ Head Notch Embossment 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.htIt1.com I an espanol 1-800-879.5000 1 Hill! (Canada) Corp. 1-800-363-4458 1 www.hlltLca I Product Technical Guide 2008 I 1. Hammer drill a hole to the same nominal 2. Clean hole. diameter as the Kwik 8oltTZ. The hole depth must exceed the anchor embedment by at least 1/4 inch. The fixture may be used as a drilling template to ensure proper anchor location. 3. Drive the Kwik Bolt 17 into the hole using 4. lighten the nut to the recommended a hammer. The anchor must be driven installation torque. until at least 4 threads are below the surface of the fixture. Hilti, Inc. (US) 1-800-819-8000 1 wwwus.hflti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hllti.ca I Product Technical Guide 2008 325